Loading...
HomeMy WebLinkAboutPermit M13-121 - FROULA ALARM SYSTEMS - REPLACE ROOF TOP UNITFROULA ALARM SYSTEMS 861 INDUSTRY DR M13-121 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049034 Address: 861 INDUSTRY DR TUKW Project Name: FROULA ALARM SYSTEMS Permit Number: M13-121 Issue Date: 07/29/2013 Permit Expires On: 01/25/2014 Owner: Name: CWWA TUKWILA 1 LLC Address: C/0 EQUITY OFFICE MGMT LLC , PO BOX A-3879 60690 Contact Person: Name: JOFFRE SECHIER Address: 3202 C ST NE , AUBURN WA 98002 Email: JOFFRE@COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P-105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425-251-9840 Phone: 425-251-9840 Expiration Date: 04/25/2014 DESCRIPTION OF WORK: INSTALL (1) 3 TON ROOFTOP UNIT WITH ECONOMIZER. INSTALL GAS PIPING FROM UNIT TO METER. INSTALL SUPPLY AND RETURN GRILLS TO OFFICES. MODIFY EXISTING DISTRIBUTION FROM EXISTING 2 TON ROOFTOP UNIT TO SERVE INTERNAL OFFICES. Value of Mechanical: $9,110.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $311.81 International Mechanical Code Edition: 2012 Date: '� %�"(3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permi does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the :%e nce •jl6ork. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this perm Signature: Print Name: JdM"ls Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. nA17 4•)1 Prinfcrl• r17_9Q_9f113 PERMIT CONDITIONS Permit No. M13-121 1: ***BUII,DING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-121 Printed: 07-29-2013 CITY OF TUKWILA Community Development Department Pet•ntil C'etuer 6300 Soullwenter Blvd. Sure 100 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: ! —( 3 • Date Application Expires: , .- —1 (For office use °nit) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: C� 1 _i Iciu5V ( ' Tenant Name: fiat fa AAA m / 5yszhw.5 ''PROPERTY OWNER Name: JJ_ `%C� Name: %r C� wAii; t (G l GZ Address: Tukwila Business License No.: City: Stade=-• Zip= _ CONTACT PERSON - person receiving all project -.communication Name: JJ_ `%C� Address: ?off 5,e „0"--� J cJ t,_ City: L� b State: '_ A Zip:(70OaZ ((Arr' 6'�%v"L)" Phone: 26.2. J.. Fax: .73 591 Email: 3,,rft. / Cofyik)iZS /? cJf . cor King Co Assessor's Tax No.: Z5Z 367 - '7'03g Suite Number: Floor: New Tenant: ❑ Yes *No MECHANICAL CONTRACTOR INFORMATION Company Name: c i r b/vice-nan Pew ( Address: 320 7 C 6 / )w - City: I_c fn State: ti /� Zip: (�G� r'5 Phone: 87,596/-707UFax: 2631 -7,3'i - Ta j ( Contr Reg No.: cam Y0).406zA. Exp Date: >l/ 5Ar 77 J 7 Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: .145.6,/( 11) 3- eon i�iyQ /jy'� tom/cir JJ vim"'/I trjire unit -� nncexr: .5t 1/ ly aro r fare Art iD e C5, ,44 dr t Z- 15,,, I r ,r �3� ba-�� �o•m � > �>U z�c> S��L �nfC�nc� d cS gjjo oo Use: Residential: New ❑ Commercial: New Fuel Type: Electric ❑ Gas Replacement ❑ Replacement ❑ Other: I1:1Applications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 rx 1 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu lia Floor furnace 1� Suspended/wall/floor mounted heater Appliance vent Repair or addition to hcatlrcfrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm lia Evaporator cooler 1� Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser lia Thermostat 1� Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/I 00,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/I,750.000 btu 50+ hp/I,750.000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR TI -IIS PERMIT. BUILDING 0 ORIZED AGENT: Signature: je4/5 Print Name: Mailing Address: 3202 C II:\Applications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 hh Date: 70-13 Day Telephone: 4G 26F ` g40 Actbct rn (J A- gtaa 2 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049034 Address: 861 INDUSTRY DR TUKW Suite No: Applicant: FROULA ALARM SYSTEMS RECEIPT Permit Number: M13-121 Status: PENDING Applied Date: 07/02/2013 Issue Date: Receipt No.: R13-02046 Payment Amount: $311.81 Initials: WER Payment Date: 07/02/2013 03:19 PM User ID: 1655 Balance: $0.00 Payee: COMFORT MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 17529 311.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 249.45 000.345.830 62.36 Total: $311.81 o.n„ro,1• r7_n,2)n1z �k3 - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ct: Pr()LA )001.4s�st�l Type f -Inspection: ';`iki AL Al e Address:Date CP( 4 J5(� Called: Special Instructions: —7 2_ c 'Z-&" --(7 C CJr Date Wanted: 1 I -- i'a.m 4 —( p.m. Requester: 3 ` — I Ph7.24 3 --3() -C" Approved per applicable codes. Corrections required prior to approval. COMMENTS: \•—/REINSPECTION FEREQUIRE D..Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit I Y 113 12 / PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Q- (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 1Z07 -It 'l ALAZIA S-STEnik Type of Inspection: FRAyio.i6- RvilGH .IN Adess: _ dg (D 1 _1._tJJ-uc Zti biZ. Date Called: r _ Rcitcth-1 J .Rc 'r -+ ," L Special Instructions: l` O,Nip t Evcc� i aje,AL Date Wanted: -7-3).-1 a.m. p.m. Requester: .3-OFr4 R 0 let k -,j — A-?pra✓t Phone No: aD(0--96g-3807 'i)t,kc-k :COW ` . ADD/ N/e Approved per applicable codes. Eg Corrections required prior to approval. COMMENTS: 045 plc.; tu@ .PFRrvt i i -- i4 .+ 1--4e-ft ell° i A tin a — N/# -g1 N 2 flail t,) G - (o? wet) ,, ) R 0 let k -,j — A-?pra✓t () 'i)t,kc-k :COW ` . ADD/ N/e i�1(tel ;c 1 C7I s \'t (3;vv s ?'vJ10,-') ``Pi-- Pto clAkiit, A ( ';,J,4 I Inspet.;dr: n I EI NSPECTION FEE REUIRED. Priorjto next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: ro's r SUBMITTAL Project TCC Bldg 23 Date Friday, June 28, 2013 Contractor Comfort Mechanical Mt3ll REVIEWED FOR CODE COMPLIANCE APPROVED JUL 18 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 022013 PERMIT CENTER Project: TCC Bldg 23 Prepared By: 3t Unit 06/28/2013 10:02AM 3t Unit Tag Cover Sheet Unit Report Certified Drawing Performance Report Spec Sheet Packaged Rooftop Builder 1.36 Page 2 of 10 Project: TCC Bldg 23 Prepared By: Unit Report For 3t Unit 06/28/2013 10:02AM Unit Parameters Unit Model: 48TCDA04A2A5-0A0A0 Unit Size: 04 (3 Tons) Volts -Phase -Hertz: 208-3-60 Heating Type: Gas Duct Cfg: Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length: 6' 2.375" Unit Width. 3' 8" Unit Height 2' 9.375" *** Total Operating Weight: 658 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA04A2A5-0A0A0 Rooftop Unit 1 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 CRRFCURB001A01 14 -inch Tall Roof Curb 1 Packaged Rooftop Builder 1.36 Page 3 of 10 Project: TCC Bldg 23 Prepared By: Certified Drawing for 3t Unit 06/28/2013 10:02AM NOTES: 1. D]MENSIONS ARE IN INCHES. DIMEN5001/S IN [ 1 ARE IN MILLIHETERS. 2. S CENTER OF 0000010 3. y DIRECTION OF AIR FLOW UNIT 481C-804 33 3/8 [8471 1B 5/8 [4121 48TC-405 33 3/8 [8471 14 1/8 03111 4810-406 33 3/8 18471 14 1/8 13111 481C-607 81 318 110511 141/8 13111 FILTER ACCESS PANEL (TOOL -LESS) COMP. ACCESS CONOENSFA 1 3/8' 1350 DIA FIELD POWER SUPPLY HOLE • PANEL • COIL - INDOOR COIL 1 3/A' 1511 DIA GAUGE ACCESS PLUG D ACCESS PANEL ' •1 1 (1(( T r -r OO BACK 2.5/8 1611 TIP CURB WIDTH 44 4-5/8 11161 ELECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 19-1/2 14911 11681 3-3/4 1951 46 3/4 111871 LEFT 32 1/4 18181 • 33 3/8 18481 UNITED P -O. .008 TECHNOLOGIES 81000010. 11( CARRIER 18811 088 (0 88880 (180 00808 INCL (MESS 0048/ ION IN 1 14 [DIP01A1(0 �8 64010(8 0641010 0 8880 4114M1 004410, 0508188(80 DS 000 0n144S 0, 00010(,10 00[0 401 003111610 8181 00110040800 0A *001111400 01 0041,001. 000404(2ER HOOD 1001(0NAL1 16 [4061 1 18-1/8 11591 1 t ! 1(41111 6-1/8 (4-1/ (36314 12-1/4 (311I21 1 � 1 1 SEE THEM THE - BASE CHART -- 25-5/B 16521 RETURN AIR 0 E ALI. -, CONDENSATE DRAIN OPENING IN 8ASEPAN 6.1/4 1S71 17-3/4 1451) SUPPLY AIR 3 y • 25 16361 11001 4- RETURN AIR 26 I1 /2 29-3/8 y 26111 (1 1) SUPPLY AIR 1 FLUE HOOD TOP 3-3/8 12-1/8 1851 13071 .�- 10-1/2 --- 14101 CONTROL BON INDOOR 810WER ACCESS PANEL ACCESS OPTIONAL FACTOR0 INSTALLED DISCONNECT HANDLE 118881 FRONT 7HRU-THE-130 E CHAR THESE HOLES REQUIRED FOR USE CRBT141.80051401. 003601 CONNECTION SIZES A 1 3/8' 1350 DIA FIELD POWER SUPPLY HOLE 8 2' 150) DIA POKIER SUPPLY KNOCKOUT C 1 3/A' 1511 DIA GAUGE ACCESS PLUG D 1/8' 122) DIA FIELD CONTROL WIRING HOLE E 3/4'-14 NPT CONDENSATE DRAIN F 172'-14 NPT GAS CONNECTION 0 2 112 ' 164) DIA POKIER SUPPLY KNOCK -0U1 7HRU-THE-130 E CHAR THESE HOLES REQUIRED FOR USE CRBT141.80051401. 003601 7HRE8DED WIRE REO'D NOTE CONDUIT SIZE USE SIZES WI.) M 1/2' ACC. 7/8' 122.21 4 1/2' ' 240 7/8- 122.21 Y 4 3/4' (001.003) 204E0 1 1/8' 128.41 Z.. 10031 1/2' FPI' GAS 1 3/16' 130.01 FOR '1HRU-THE-BASEPAN' FACTORY OPTION. 1(111NG5 FOR ONLY Y.Y. 8 2 ARE PROVIDED SELECT EITHER 3//' OR 1/2' • FOR POWER. DEPENDING ON WIRE SIZE /001) P00VIDE5 3/4- FPI 7X00 CUR8 .. FLANGE 8 FITTING. 11-3/8 SUPPLY AIR 31 1/1 1793) RIGHT RETURN AIR BAROMETRIC RELIEF FLOW 34¢1 1 OF 2 11-24-08 UnKOES 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 104 5.0 Packaged Rooftop Builder 1.36 Page 4 of 10 Project: TCC Bldg 23 Prepared By: Certified Drawing for 3t Unit 06/28/2013 10:02AM CORNER A TOP FRONT UNI0ED 5.0. 405 4454 13)3/40(06)(5 sauas[. 55 CARRIER 11E01 15)5 40.0)x1 15 151 5104[515 a [555IE4 COrTs rla 1(0 I5 0(41I[5[4 0505 ISC 1555055 (015(1(01 1x.1 1M [Cn[nS 4555 Mi 4[ DISCLOSED a 1([I 1(15051 44tl [5 c4550una•s mrro canal. K5000 5044 05 1514[ Pu1510 10 a0.W[OS Dols 501 louma5E r.1( 44541. a +cunnc[ a (014¢1. CORNER 8 CORNER C MEI 4uc 11-24-08 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 REI 5.0 Packaged Rooftop Builder 1.36 Page 5 of 10 STD. UNIT 0E(GH1 CORNER WEIGHT 1A1 CORNER 011010 (8) CORNER WEIGHT IC/ CORNER WEIGHT 101 C G. HEIGHT UNIT LBS. 16. LBS. 15. L85. KG. LBS. KG. LBS. KG. K T Z 1810-601 183 219 111 50 125 51 131 59 116 53 39 [9911 23 [5841 16 3/8 (4161 4810-405 531 241 124 56 139 63 145 66 129 59 39 [9911 23 [5841 11 14321 4810.606 569 258 131 59 141 67 154 70 137 62 39 [9911 23 [584) 11 1/4 [4381 4810-401 652 296 150 68 169 16 116 50 157 71 39 [9911 13 35817 20 1/8 1511) CORNER A TOP FRONT UNI0ED 5.0. 405 4454 13)3/40(06)(5 sauas[. 55 CARRIER 11E01 15)5 40.0)x1 15 151 5104[515 a [555IE4 COrTs rla 1(0 I5 0(41I[5[4 0505 ISC 1555055 (015(1(01 1x.1 1M [Cn[nS 4555 Mi 4[ DISCLOSED a 1([I 1(15051 44tl [5 c4550una•s mrro canal. K5000 5044 05 1514[ Pu1510 10 a0.W[OS Dols 501 louma5E r.1( 44541. a +cunnc[ a (014¢1. CORNER 8 CORNER C MEI 4uc 11-24-08 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 REI 5.0 Packaged Rooftop Builder 1.36 Page 5 of 10 Project: TCC Bldg 23 Prepared By: Certified Drawing for 3t Unit 06/28/2013 10:02AM ROOF CURB ACCESSORY* A CRRFCURB001ADI CRRFCURB002A01 210 )610] 15 14 NOTES: 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. 2. INSULATED PANELS 25.4 01 THK POLYURETHANE FOAM. 44.5 )1-3/4) * DENSITY. 3. DIMENSIONS IN I ARE IN MILLIMETERS. 4. ROCFCURB: 16 CAGE STEEL 5. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB). 6. SERVICE CLEARANCE 4 FEET CN EACH 5/0E. 7. DIRECTION OF AIR FLOAT. 8. CONNECTOR PACKAGE CRBTMPWROOIA01 I5 FOR THRU-THE-CURB GAS TYPE PACKAGE CRBTMPWRO03A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS. 547 137.71 11.66" p03.8) -4- 1 21.74' (552.2] 11 I 1 , ''s4J 26 6OJ ' 70.87 )1800.: 1 LIT 58) I r i.0v ( 117621 RETURN AIR OPENING 01/341445) 1 es -- - 2184- 155471 1554.71 E E 32.,9• 1 00- 51� SUPPLY AIR OPENING 1 1607" X7;21 )8,7.6, 1.75- J1 04.5] 1..-20.41- -.4 818.31 4069- -31100- (7621 3.78- -o- 1350•01 � 4816 11155] 11033.5] VIEW "B" CORNER DETAIL GAS (SUPPLIED WITH CURB) DUG (FIELD SUPPLIED) UNIT CONNECTOR PKG. ACC GAS CONNECTION TYPE CAS FITTING POWER WIRING FITTING CONTROL WIRING FITTING ACCECCORYCONVENIECE OUTLET WIRING CONNECTOR CRBTMPWR001A01 THRU THE CURB 3/4- )19) NPT CRBTMPVJRO13A01 THRU THE BOTTOM 1/2- 1121 NPT 314" )19) NPT 12 )1271 NPT 12)12.7]NPF 1 -3/4 -hi 1 1-3 1 1.00. R54] I-4441 1314' (44 4) SECTION E -E SCALE 0250 NAIL (SUPPLIED WITH CURB) TYPICAL (4) SIDES OUNTER FLASHING (FIELD SUPPUED) ROOFING FELT (FIELD SUPPLIED) CANT STRIP (FIELD SUPPLIED) ROOFING MATERIAL (FIELD SUPPLIED) CRRECURIN01/01. [SOAR, WA S ACC NEW PARTS AND DRAWS.K.3 RIGID INSULATION (FIELD SUPPLIED) 06/11/11 RUC MAC 11 3/41298 5] WIDE INSULATED DECK PANELS 89/18)217.5] WIDE INSULATED DECK PANEL GAS SERVICE PLATE THRU THE CURB DRILL HOLE 0 71,0.6] ASSEMBLY (IF REQUIRED) (SEE NOTE IB) !411 6'3/1 1110 19N 6] SEE VIEW 'B' CERTIFIED DRAWING S )1723.9) SEE NOTE *2 1-3/4" 144.4] DRUMM RELEASE /050/. PRODUCTION RIATERAL MEMO.. ARE IN MILMSETERS SM _1 T& 3.2M • 1 •1.0 •050 • 2- 44 Carrier A Unitl T*,*was 0 O E. ▪ ▪ LOEDOR OCCLOSEDIO OTHERS Di .1101.4 a•LOI 10417344 LOS, YL02 ETIONEERNO IiIAMUSACTIRINCI CURB ASY, ROOF 1(004 001 10627.14 DRAFTER MMC 06117/11 D ,,,RAw4b 48TC400427 E, 5015 A SURFACE RMS. REV REVROON RECORD or PURCH m¢IN1E.Nu USE Pin NEXT DRAWN0 N/AE orrosurou 900 Packaged Rooftop Builder 1.36 Page 6 of 10 Project: TCC Bldg 23 Prepared By: Performance Summary For 3t Unit 06/28/2013 Part Num ber:48TCDA04A2A5-0A0A0 ARI SEER. 13.00 Base Unit Dimensions Unit Length: 74.4 in Unit Width:. .-----....... ' 44.0 in Unit Height. 33.4 in Operating Weht Base Unit Weight. 483 |b Medium Static Option: 10 |b Accessories Vertical EconoMi$er IV with solid-state controller su |b 14 -inch Tall Roof Curb. 115 lb Total Operating Weight 658 lb Unit UnitVuKoge'PhaaeHartz. 208-3-60 Air Discharge: -- Vertical Fan Drive Type Belt Actual Airflow: 1200 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 96.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering A1rWB: 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB: 59.7 F Evaporator Leaving Air WB: 67.7 F Evaporator Leaving Air Enthalpy: 24.84 BTU/|b Gross Cooling Capacity 35.65 MBH Gross Sensible Capacity: 2$.26 MBH Compressor Power Input 2.48 kW CoiI Bypass Factor: 0.186 Heating Performance Heating Airflow. 1200 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 116.6 F Gas lnput Capacity: 72.0 MBH Gas Heating Capacity 69.00 MBH Temperature Rise. 45.5 F Supply Fan External Static Pressure: 0.60 in wg Options /Accessories Static Pressure Economizer: 0.04 in wg Total External Static: 0.54 in wg Fan RPM: 846 Fan Power: 0.44 BHP NOTE: Selected IFM RPM Range: 770 - 1175 Electrical Data (Before July 3�201:q KNnimumVo�g . 187 Maximum Voltage253 CompeoonrRUA. 10.4 Compressor LRA. .73 Outdoor Fan Motor Qty 1 Packaged Rooftop Builder 1.36 Page 7 of 10 Project: TCC Bldg 23 Prepared By: Performance Summary For 3t Unit 06/28/2013 10:02AM Outdoor Fan FLA (ea): 1.5 Indoor Fan Motor Type: MED Indoor Fan Motor FLA:.... 4.9 0.24 Power Supply MCA: 19.4 Power Supply MOCP (Fuse or HACR): 25 Min. Unit Disconnect FLA: 19 Min. Unit Disconnect LRA. 89 Electrical Convenience Outlet: None Combustion Fan Motor FLA (ea): Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA: 5.2 Power Supply MCA: 20 Power Supply MOCP. 30 Disconnect Size FLA: 20 Disconnect Size LRA: 96 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 83.6 85.5 90.6 125 Hz 76.4 73.6 80.9 250 Hz 66.0 59.2 80.2 500 Hz 62.7 58.8 76.0 1000 Hz 59.3 58.5 74.6 2000 Hz 53.8 52.5 71.3 4000 Hz 54.9 47.4 68.5 8000 Hz 49.1 39.0 63.9 A -Weighted 66.7 64.7 80.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Packaged Rooftop Builder 1.36 Page 8 of 10 Project: TCC Bldg 23 Prepared By: Performance Summary For 3t Unit 06/28/2013 10:02AM Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 90.6 80.9 80.2 76.0 74.6 71.3 68.5 63.9 91.7 Lw B 64.4 64.8 71.6 72.8 74.6 72.5 69.5 62.8 79.9 LwA C 58.2 48.5 47.8 43.6 42.2 38.9 36.1 31.5 59.3 Lp D 32.0 32.4 39.2 40.4 42.2 40.1 37.1 30.4 47.5 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2.0 1.8 1.6 '.,1100 RPM Fan Curve V 1500 R PM \\ 3.00 BHP-. 900 RPM 1.4 1.2 0) 1.0 0_ o 0.8 c0 co 0.6 0.4 0.2 0.0 - 700 RPM 2.00 BF1P� 500 RPM 00 03 06 0.9 12 15 Airflow (CFM - thousands) RPM = 846 BHP = 0.44 Maximum RPM = 1175 Maximum BHP = 2.40 Note: Please contact application engineering for selections outside the shaded region. SC - System Curve RP - Rated Point 0.50 BHP', rte 18 50 BHP- 1.00 BHP 21 24 Packaged Rooftop Builder 1.36 Page 9 of 10 Project: TCC Bldg 23 Prepared By: Spec Sheet for 3t Unit 06/28/2013 10:02AM Packaged Rooftop Builder 1.36 Page 10 of 10 Pr REVIEWED FOR CODE COMPLIANCE APPROVED JUL 18 2013 City of Tukwila BUILDING DIVISION %% , F wast',` �� -18959 ‹,O ,r J FGlsTE��,�1 t„ ONALE EXPIRES Gi! ' ``7 STRUCTURAL CALCULATIONS Tukwila Commerce Center RTU 863 Industry Drive Tukwila, Washington JUNE 28 , 2013 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington Moore Engineering Group RECEIVED CITY OF TUKWILA JUL 0 2 2013 PERMIT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD MECHANICAL UNIT EARTHQUAKE WIND 25 PSF 658 POUNDS SDS = 0.913 SITE CLASS D to E 85 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (4x MEMBERS) HEM -FIR NO. 1 Fb = 975 PSI, Fv = 150 PSI 8. TIMBER CONNECTORS CALLED OUT BY LE I I ERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-2013. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 10. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. Moore Engineering Group PROJECT: 1-orwi LA- C 14-r2c� ENGR: K.\\`E' DATE: 62(28 /15 SCALE: SHEET PROTECT DESCRIPTION: The project consists of a new rooftop mechanical unit on an existing wood framed roof structure. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 5.0 Plywood sheathing 1.5 2x4 @ 24" o.c. 0.7 Joists ® 8' o.c. 1.8 Insulation 1.0 MEP 2.0 Ceiling & Lights 2.0 14 PSF TOTAL DEAD + LIVE 39 PSF WIND 85 MPH, Exposure B, 11 PSF SEISMIC Latitude 47.450 Longitude -122.249 Site Class D to E SDS (D) = 0.961 SDS (E) = 0.865 SDS = 0.913 EQUIPMENT New Unit 508 Curb 115 Economizer 35 Total 658 Dimensions 74"x44"x47" High Moore Engineering Group PROJECT: Thv-» L K4 eigsz CE► re-- 'TL) ENGR: DATE: y8A5 SCALE: SHEET )esign Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mi.. ritUSGS Design Maps Summary Report User -Specified Input Report Title Tukwila Commerce Center RTU Sat June 29, 2013 02:55:44 UTC Building Code Reference Document ASCE 7-10 Standard (which makes use of 2008 USGS hazard data) Site Coordinates 47.45°N, 122.249°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III •."77' ' S:'KUbo a•. Ilidhline ,r Garden :j, ild1 md•Park ; . Maple erliPights-1 p' eMoines fies, -etc? Gren iview O/I`_ :• USGS-Provided Output East Hill-Meridia SS = 1.441 g S1 = 0.536 g S = 1.441 g MS SHl = 0.804 g SF 74(11 . Idexicti SDS = 0.961 g SDI = 0.536 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 0.90 H 0.75 0.60 0.45 0.30 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.20 Period. T (sec) 2.00 1.10 1.00 0.90 0.20 0.70 11 0.60 N 0.50 0.40 0.30 0.20 0.10 0.00 0.00 For PGAM, TL, CRS, and CR1 values, please view the detailed report. Design Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.20 Period, T (sec) 2.00 of 2 6/28/2013 7:55 PI )esign Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mi.. m(GS Design Maps Summary Report User -Specified Input Report Title Tukwila Commerce Center RTU Sat June 29, 2013 02:56:02 UTC Building Code Reference Document ASCE 7-10 Standard (which makes use of 2008 USGS hazard data) Site Coordinates 47.45°N, 122.249°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III vi .'* Kubota ' ' Fiiohline ',`.:- 'Garden. , 3, I 91 •'t< 1: 1'trrand Perk' tures Tukwila518 East Rensbn- Highlands `-• Ron am:. • Park • Normandy Park SeaTic• • Maple IifeightR-take j(- • Des h�toines Grand'vr'tv.Off . r,. c1• �::.. 1-3 4F'am �. Mexico East Hill -Pendia United States USGS-Provided Output Ss = 1.441 g S1 = 0.536 g Sas = 1.297 g S = 1.287 g SDS = 0.865 g SCI = 0.858 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.43 1.30 1.17 1.04 0.91 0.78 0.65 0.52 0.39 i 0.26 0.13 0.00 0.00 0.20 MCER Response Spectrum 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period. T (sec) Design Response Spectrum 0.99 - 0.90 - 0.81 - 0.72 - 0.63 - OI 0.54 - {n 0.45 0.36 0.27 - 0.18 - 0.09 - 0.00 1 i I 1 1 1 1 1 1 1 2.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 Period. T (sec) For PGA M, T, CRs, and CR1 values, please view the detailed report. of 2 6/28/2013 7:56 PIV. 1 11L mia ilia_ II 1 ■ : 1 . • . _ MI • f ■ p 1 IN MI ... 111111 i ..... , ..._ vq.01 ■r alan In al JcMl _■ f 05.. - .4 'I'7 Cci 7 -off , ( ■ ( il • Li • ein • au auat A- . 1a, Via ail. i 111 millisIP Ifit.--- Pell i ■ linsaan I I m r ■� _ _ ■ ma . ;fir .. 011 i __A p f✓' �, CT's �I — , ,!MTI i11� y 1 I ,. Project: TCC Bldg 23 Prepared By: Unit Report For 3t Unit 06/28/2013 10:02AM Unit Parameters Unit Model: 48TCDA04A2A5-0A0A0 Unit Size: 04 (3 Tons) Volts -Phase -Hertz. 208-3-60 Heating Type• Gas Duct Cfg: Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size' 3/4 Return Air Filter Type: Throwaway Retum Air Filter. Quantity: 2 Retum Air Filter Size: 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu -AI/Cu , Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. In.) & Weight (Ib.) "* Unit Length: 6' 2.375" Unit Width- 3' 8" Unit Height 2' 9.375" — Total Operating Weight: 658 Ib "' Weights and Dimensions are approximate. Weigh does not indude unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dmensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 600-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA04A2A5-0A0A0 Rooftop Unit 1 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 CRRFCURB001A01 14 -inch Tall Roof Curb 1 Packaged Rooftop Builder 1.36 Page 3 of 10 b 1( Project: TCC Bldg 23 Prepared By: Certified Drawing for 3t Unit 06/28/2013 10:02AM NOTES: S t 1. Oil E451 (9 11411141[165!)"531"5 2. B CENTER OF GRA4111 3. DIRECTION OF AIR ELON 4500.804 13 1/1 18471 105/5 14721 46TC•A05 (54111 141/13 (211) 40TC-807 33 516 1847) i47/5 13711 461C•831 41 I/5 110511 11'1/6 0311) FILTER ACCESS PANEL (TOOL -LESS) • CORP, ACCESS • PANEL o CONDENSER I COIL � 140003 COIL ACCESS PANEL 1)11 3 BACK 1/ 1)111) 4.516 11163 ELECTRICAL 013[0041(1 LOCATION OPTIONAL FACTORY 1NS1ALLED C0NIENIENCE OUTLET 31.1(2 ` 14641 3.3/4 1951 40 3/4 111011 LEFT 313/5 31316 18161 0 MID r.0. 6x1Ams 7E0150104106 lrucaa. �. CARRIER 11511 5011113 1142"1107 5("0111401 a( �tciYlslwti""7AAA"In 00a05A1)0r'1 411110, 15705 51. 1411.",16131411141-'441' 50 0 11 f1. ' scarAla a canicT, • 1 10010412E1 11000 (OPTIONAL! 1 } 16.1/6 1 14511 1141I 36311' 1)4 111114 11 1 i • z JSEE EMU THE— SAS0.CNAR1 25 1635) 11001 — 15.5/8 (632) AMAX AIR 16 14551 (0.1/5• 127)) RETURN AIR E ALT. CONDENSATE DRAIN OPINING IN BASEPAN 0 (5.7/6 411511 EU 5000 TOP 17.3/4 1451) SUPPl1 A16 I 26 -ill 111116 1SUPPLY 6731 AIR 11170.141.88 E CHAR THESE NOUS REQUIRED FOR USE CRBTNPNR0D1A01. 003801 C0311E01104 SUES A 1 3/8' 1351 DIA FIELD POWER SUPPLY 801E "8. 2' 1501 01A POWER SUPPLY 090(3001 C 1 3)4. 1511 014 6400E ACCESS PLUG 0 1/8' 1221 0IA F)CLO CONTROL 617140 MOLE ( 1/4'•14 API COROE4IATE DRAIN T 1/2'•14 431 GAS C09NECT109 0 2 1/2 ' 1643 DIA P01ER SO7PL1 590(7.081 11170.141.88 E CHAR THESE NOUS REQUIRED FOR USE CRBTNPNR0D1A01. 003801 THREADED MIRE 57010 H0)E CONDUIT SITE USE SIEE3 )45I.) 11F' ACC. 1/6" 1(2.2) I 712' 244 7/5" 122.2) 1 r 3/4. 1001.0031 POWER 1 1/8' 128.41 E." 10031 IR' 1711 OAS 1 3/19' 110.03 F06 . INR0•T6E•6ASEN4' TALENT OPTION. FITTINGS TOR ONLY 0.1, 8 ARE PR0010(0 SELECT EITHER 3/4' OR (12' " TOR POWER. DCPE631M0 ON WIRE SIE 1001) PR01(0ES 3/4' EPI THAD CURB ' r FLAW 8 1(10)60. OPTIONAL EACTCRY INSTALLER DISCONNECT 118661 FRONT 06 3/1 6941 31 1/4 119)) AUPPIT AIR Af ARETURN RIGHT BAEALI01422 FRIG 110* 4..n 11-24.08 1)7141)X1 09-29-08 48TC 04.07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48104500993 u• 5.0 Packaged Rooftop Builder 1.36 Page 4 of 10 Project: TCC Bldg 23 Prepared By: Certified Drawing for 3t Unit 06/28/2013 10:02AM ROW CURB ACCESSORY(' A CRRFCUR8001PO1 1C CRRFCURS02aM1 18 14 NOTES: 1. ROOFCURSACCESSORY IS SHIPPED CISAB3B1OLE0. 2. INSULATED PANELS: TSA 11)70K POLYURETHANE POW, 44D(141q# DENSITY. 3. DIMENSIONS IN ARE IN MRLIME1ER8. I. ROOPCUR8: 10 GAGE STEEL. S. ATTACH DUCTWORK TO CURB. (FLANGE/10F DUCT RESTON CURS} 0. SERY)CE CLEARANCE 4 PEETON EACH SIDE 7. ��TOR PACKAGE AOFAR7I. N.. 0. CONNECTOR CRPACKAGECRBTMPNRWIA01 ID FOR 1HRU•THE OAS CONNECTIONS. 5,42' PACKAGE CRBTMPYMOOSAM 0 FOR THRUFTHE�OTTOMTYPE OAS CONNEOTNRIS. BA2' -•-+ 1101.71 1 U 1303/31 '+- 21.7r 155221 ALS 260) R1n (17381 1 18• 1`S� RETURN NR OPENING f81/Y41 1 / / E E I OD 5.131 i SUPPLY AR OPENING 132.11r1 15.0T 10:a El 18178 I3 -1 RA51 ..-- 20.41. --... 1510.3) 40 SFr - 7.00• 176,21 1J.7r -. WOG) P9 •87r 0100) 1131 VIEW "B• CORNER DETAIL (SUPPLED WITH CURB) DDC MELDDUPPLED) UNIT CONNECTOR PKG. ACC. OAS =MECUM/4 TYPE GAB FITTING POWER WRING FfRO(G CONTROL WRING PRONG ACDECCORY CONVENECE OUTLET WIRING CONNECTOR CRBTMP76RDOIAOI 7HRU 7NE CURB SN'I18JNPT CRSTMPWROC3A01 TAU TNS BOTTOM 1/2 11271NPT 7U• (117 NPT 1?(12.7)NPT 10 (I RPT 1,314. NAB SECTION E -E SCALE 0230 NAM (BUPPLED WITH CURD) 'TYPICAL POWDER COUNTER FLASHING (FIELD SUPPLED) ODPINO FELT MELD SUPPLED) CANT STRIP (FIELD SUPPLED) ROOFING MATERIAL (FIELD SUPPLIED) *PRY AR 011111R.011116.1/41,11.2.1.11/01 1eW 1YarsMOOM101m INSULATION (FIELD SUPPLIED) 01011 w0 11 3MT298811MDE INSULATED DECK PANELS 8 WI TED17.81YNDE M DECKPANEL CAE SERVICE PLATE THRU THE OURS DPoLL HOLE 0 2'1EGg ASSEMB5YSF REQUIRED) (GEE NOTE ON /tea. 1111111110 J.13Ir NO, el SEE VIEW'S' MAY wird CERTIFIED DRAWING 57.7M' 7727.01 SEE NOTE n /413W 1«.g D+a•.IDRDA.aum: PRODUCTION Dap _gamy. 61/0.1.13•011110 Yal..1.17•1111 ARID JESS 10.6 06 r 1 •1O .020 • 2• CDNIBI 216 d1sawhd•a CNrple Tlp W1RMR W 110tROW WqI lODN10DRWC1 UMW= v0R}Ip NAIK•WAAR10I0•NLLU 1nN00A14 NIIIICIWna1.11eaR 1001181 * aa6won*I0 TOM 7. 07 m eao INWORIVIVIIMO CURB ASY, ROOF eeo0 MMC OINTNI aax D w111.10 *NMI TC40DM127 near SaS 415 A .u1Rw mol AIY 14 18D0 ROD AD DWI OK'D uP•D I CR RD AMESEEP PURSE 121 7 EMP* 41 *0. WA NMC Packaged Rooftop Builder 1.36 Page 6 of 10 . r i i I .1 I , I- , , 1.-4'4dV& - • • , f(eiv-Fir t- 1, > ;- t • • 1 I I LUis i ! .. , ,.. : , ir----- -t , . , , . .• i . 1• 1 I ! 1 I 1 1 , . , i; 1— I ' ) 7-/ •-;--i•, Zoo i i ) .. , :1 1 . s ;1,1W/I i •(.77 f ; d, -0A1 il : ! ! by -e C3'ci 1)11- ,, ........,,,...1_...._: , .._,.... ...., A .. _ . . _ . c . 7 —; • : 4 • • : ; 1 ! I ! 41,••• I ' ! 74ele7- 21, 4c,4 • ,H_,i____/_.......,_.., ; 1...... ;...... ,• I 1 .57q 4 i i .11'-‘4't ic,l, "'AI 7444,L.4_ -t%- I ! ! , ! • ; : ! I • 1 1 I 7 ! 1 ! i 1 1-- • 4 , • -i I t ! ; 51(3 i i• , --Ipt I— 0itylt-E_ I — 4 ---•.1;.i.., 11 I:I .- 4Qp,,._ I; , 1 ....0 ,.1.. .. : 1 : I 1' j_ _1I .p -e,-- '1:f20 140T, I . ; 1 , ; ! • ; ; • i In '.'t) 04-i;c1. 1-01i-CA:st len-,,,I -11-0 1 1 . i • : 7. . 4 •I :I I - -I , - - ! ! -I I • ! ! ! I • ' I I ! ; 1 I ! ,•••• , I -V- ; • H -..-'-i , j j II I • I i I i I 1 ; , ! : 1 . I 1 . ! I ! ! . 1 1.- ----!—.1-- I.___Lf ..Y'l.... _ .1 • ! 4 ,_ , i --i - .. . i :1 - 1 i 1-- -- !' t 1 111 ; : I • ‘a i : • • I , I •11:: 1 • I 1,0 ; • ,-- -,(0,,.,(4) A ) .._..._.. • Jeiti 1 , : • 14:> (0 - -i• • I rii-ek-C-4 Mdore Engineering GrOup PROJECT: LA-Uovi CrtELTD ENGR: DATE: 648 /1'S SCALE: '¼ SHEET • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-121 DATE: 07-02-13 PROJECT NAME: FROULA ALARM SYSTEMS SITE ADDRESS: 861 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPARTMENTS: 13 in ivision Public Works ❑ Fire Prevention Structural • Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ffi Incomplete DUE DATE: 07-09-13 Not Applicable Comments: Permit Center-Use;Onlyd. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-06-13 Approved ❑ Approved with Conditions X Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL UBI No. 601954041 INC Phone 4252519840 Status Active Address 3202 C St Ne License No. COMFOMI015LA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 6/1/1999 State WA Expiration 4/25/2014 Date Zip 98002 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM*010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/1999 5/1/2014 Active COMFOP*064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEYA President 01/01/1980 Bond Amount JACKSON, HERB J Vice President 01/01/1980 9815017 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 Lexon Ins Co 9815017 06/01/2012 Until Cancelled $6,000.00 06/04/2012 2 COLONIAL AM CASE SURETY OF MD LPM4041162 06/01/2002 Until Cancelled 06/01/2012 $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Federated Mutual Ins Co 9849307 06/01/2010 06/01/2014 $1,000,000.00 05/20/2013 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 07/29/2013 PARCEL Parcel 252304-9034 Number J Name I CWWA TUKWILA 1 LLC Site ; 825 INDUSTRY DR 98188 Address Legal J BEG ATE 1/4 COR OF SEC 26-23-4 TH N 88-06-42 W 105.84 FT TH S 01-47-28 W 90.66T TO TPOB TH I FR TPOB S 88-12-32 E 233 FT TAP ON C/L OF A PRIVATE DRIVE TH ALG SD C/L S 01747-28 W 577.17 , FT TAP OF CURVE TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO' LFT 77.78 FT i 1 RAD 250 FT & C/A 17-49-33 TAP OF REV CURVE TH FR A TANGENT WH BEARS S 1* -02-05 E ALG 1 ARC OF CURVE TO RGT 77.78 FT RAD 250 FT & C/A 17-49-33 TAP OF TANGENCY T TANGENT TO 1 PRECEDING CURVE S 01-47-28 W 430 FT TAP ON NLY MGN OF MINKLER BLVD T LEAVING SD (C/L ALG SD MGN N 88-12-32 W 257 FT TH LEAVING SD MGN N 01-47-28 E 1160.23 F.' TO TPOB LESS UP RR OPER R/W L BUILDING 1 Year Built Building Net Square Footage Construction Class Building Quality Lot Size Present Use Views Waterfront ASSESSOR DATA 1978 10500 MASONRY AVERAGE (251238 Industrial Park 1 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical o, Electrical 14 Plumbing Gas Piping City of Tukwila BU1LDNG DIVISION 0223400071 ;623049112 25304900a AREA OF WORK { River 3arlul4 76;,4 3 Tukwila 2523049034 2623049019 ' I; ,I • ICI 9008 King County 2627049 ?U5 [62309140 2523049075 21230490:1 Green 2923049071252 • II •, 613049D16 2524949070 aER BLVD .__. 11931t SITE PLAN FILE COPY PemnNo. 109•);121 Lu 41 Plan review approval is subject to errors and omission. Approval of construction documents does not authe. Mc, v oia'don of a)y opted code or ordinance. Race, of approved F%: ,_ ; tI, 3f; i .ns is acknowledg BY • ,t 7 -7- City Of Tukwila BUILDING DIVISION •Bl.d22: :.�.W • rnalxlUast. 1 (100m , 1200ft 1 VICINITY MAP : 02013 Mapquesl- Portions ®2013 NxVTEQ,iiv Terms 1 Pracvi • PROJECT DESCRIPTION: 1. INSTALL (1) 3 -TON ROOFTOP UNIT WITH ECONOMIZER. 2. INSTALL GAS PIPING FROM UNIT TO METER. 3. INSTALL SUPPLY AND RETURN GRILLS TO OFFICES. 4. MODIFY (E) AIR DISTRIBUTION FROM (E) RTU -2 TO SERVE INTERNAL OFFICES. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. 7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 4. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 5. INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM. 6. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 7. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 8. PROVIDE O&M MANUALS WITH STAFF TRAINING. 9. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 10. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 11. INSULATE ALL DUCT PER WSEC TABLE 14-5. 12. SEAL ALL DUCT PER WSEC. HVAC Equipment Schedule REVIEWED FOR CODE COMPLIANCE APPROVED JUL 18 2013 fari City of BUILDING vt Iia ISION # Brand Model Ton CFM OSA CFM Econo. SP Cap. Cool SEER Btuh-In Btuh-Out AFUE RTU -1 CARRIER 48TCDA04 3 1,200 50 0-100% 0.5 35,650 13 72,000 59,000 82% INSTALL (N) GAS PIPING 3/4" PIPE @ +/- 80 LIN. FEE vcp retAisre INSTALL UNIT E) RTU -2 "NO WORK" RTU -1 PARTIAL ROOF PLAN 2009 Washington State Energy Cede Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary 2009 Washington State Energy Code Compliance Forms for lolresidential and Multifamily Residential Revised February 2011 Project Info Project Andress FROULA ALARM SYSTEMS Date 7/2/20 13 ) 861-863 INDUSTRY DRIVE. For Building Dept. Use TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 3202 C ST NE, AUBURN, WA 98002 Applicant Phone: 425-251-9840 Project Description INSTALL Briefly describe mechanical PIPING system type and features. TO OFFICES. Li Includes Plans Include cocumentation (1) 3 -TON ROOFTOP UNIT WITH ECONOMIZER. INSTALL GAS FROM UNIT TO METER. INSTALL SUPPLY AND RETURN GRILLS MODIFY (E) AIR DUCT TO SERVE INTERNAL OFFICES. requiring compliance with commissioning requirements, Section 1416. (4)Simp-> System ()Complex System 0 Systems Analysis Compliance Option (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The folloiving information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity 2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU -1 RTU CARRIER 48TCDA04 35650 ECONO 13 ECONO N Heating Equipment Schedule Equip. ID Equip Type Brand Name' I Model No.1 Capacity 2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N RTU -1 RTU CARRIER 48TCDA04 72000 ECONO 72000 59000 82 N Fan Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service 11f available. 2 As tested according to Table 14-1A through 14-1 G. 3 If requi ed. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV) or variable speed (VS). 6 Exception number from Section 12" RND. • REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 11 I 200 CFM •--- RND. TYP 6 200 CFM FLOOR PLAN 200 CFM 200 CFM • Therm. 200 CFM 200 CFM 200 CFM (E) RTU -2 AIR DIST. MODIFICATIONS 200 CFM M 13e=11- 12.1:.. REVISIONS ci z MECHANICAL COMFORT co 0) co M M 10 N N co 0 <. I— oho N V 10 sgt CD °° 10 Cr) Q VJ W (1) 00 >- . 00 cr) Lt. r 0 � 2 cm cr >— Q j I- D D Z Ori cC co oo I -- DATE: SCALE DRAWN: CHECKED: RECEIV2u 00-000 CITY OF TUKWILA JUL 022013 PERMIT CENTER