HomeMy WebLinkAboutPermit M13-122 - GAP - REPLACE ROOF TOP UNITGAP 1051 S 0 UTH CEN1 ER MALL M13-122 Parcel No.: Address: City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 1051 SOUTHCENTER MALL TUKW Project Name: GAP Permit Number: M13-122 Issue Date: 07/24/2013 Permit Expires On: 01/20/2014 Owner: Name: Address: Contact Person: Name: Address: Email: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 MICHAEL ATWOOD 9630 153 AV NE , REDMOND WA 98052 MATWOOD@MERITMECHANICAL. COM Contractor: Name: MERIT MECHANICAL INC. Address: 9630 153 AV NE , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425-883-9224 Phone: 425 883-9224 Expiration Date: 06/01/2015 DESCRIPTION OF WORK: LIKE FOR LIKE REPALCEMENT OF (1) EXISTING ROOFTOP UNIT FOR GAP AT SOUTHCENTER MALL Value of Mechanical: $5,125.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Laria Fees Collected: $261.56 International Mechanical Code Edition: 2012 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signatu Print Na X r7 Date: —2 (- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J..... IRA/' A 11 M14-177 Printed. 07-24-2013 • • PERMIT CONDITIONS Permit No. M13-122 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2)(ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this doc: IMC -4/10 M13-122 Printed: 07-24-2013 project. • 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. .d..n• IRA(` A/1A M11-197 Printed: 07-24-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Tit t3--) ,2 Project No. Date Application Accepted: 13 Date Application Expires:�— (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1051 Southcenter Mall King Co Assessor's Tax No.: 9202470010 Suite Number: Floor: 1 Tenant Name: GAP PROPERTY OWNER Name: Michael Atwood Name: Westfeild Property Tax Dept City: Redmond State: WA Zip: 98052 Address: Email: matwood@meritmechanical.com City: State: Zip: CONTACT PERSON - person receiving all project communication Name: Michael Atwood Address: 9630 153rd Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: Email: matwood@meritmechanical.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc. Address: 9630 153rd Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: Contr Reg No.: MERITMI 1 63CM Exp Date: 06/01/2013 Tukwila Business License No.: 0992852 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Like for Like Replacement of (1) existing Rooftop Unit for GAP at Southcenter Mall. 5,125 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 0 Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 :-� Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit 1 >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper 1 Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 1 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMITtAPPLICATION NOTES L. Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN. OWN OR AU ORI D AGENT: Signature: Date: 07/03/2013 Print Name: Michael Atwood Day Telephone: (425) 883-9224 Mailing Address: 9630 153rd Ave NE H:\ Applications\Forms-Applications On Line\201 I Applications \Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Redmond WA 98052 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M13-122 Address: 1051 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/03/2013 Applicant: GAP Issue Date: Receipt No.: R13-02056 Payment Amount: $261.56 Initials: WER Payment Date: 07/03/2013 11:14 AM User ID: 1655 Balance: $0.00 Payee: MERIT MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24855 261.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 209.25 000.345.830 52.31 Total: $261.56 e nn• unneinf _AC Dpi.,+or• z INSPECTION NO. INSPECTION RECORD Retain a copy with permit k3 -)22 -- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v. (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: Address:Date Sm (05 1 ITrtC'CrrriFR «\ Called: A 1. -(------- -(_ —Special SpecialInstructions: Date Wanted: _� -2-,p.m. a.m Requester. Phone No: 'pproved per applicable codes. E1 Corrections required prior to approval. COMMENTS: '?:::)1 erv‘i Ifispectd Date8-i- INf'ECTION FEE REQU ED. Prior to nex inspection, fee must be pa' of 6300 Southcenter Bl d., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v2_, (206) 431-367 Permit Inspection Request Line (206) 431-2451 b`%—at Projee,q Ty%e-off (Inspection: Ad 1 0ess S ! SC J4 (1 DatealCd' (1) 'C.); . — OA) Special Instructions: / Date Wanted. —L3 p.m. Requester: Phone No: •1 -2,g ---414-C-101? Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 65)K lc (ata eeJ Ins ector: Date: _3(—/3 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • PERMIT COORD COPY PLAN REVI r::SIV/ROUT LIP ACTIVITY NUMBER: M13-122 DATE: 07-03-13 PROJECT NAME: GAP SITE ADDRESS: 1051 SOU T HCENTER MALL X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: gdinatS'on I Public Works Response to Incomplete Letter # Revision # After Permit Issued 3 Fire Prevention IN Strucl 1ral DETERMINATION OF COMPLETENES'': ��� les., Thtirs.) Complete Comments: Incompleln Inrninq Division Rr„-mit Coordinator n 7-09-13 "Int nrrlicable ❑ Permit Center Use. Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Reouired REVIEWER'S INITIALS: No further Review Renuired Dl APPROVALS OR CORRECTIONS: D' .: r, TE: 08-06-13 Approved ❑ Approved with Conditions i Not Anna • ^nmments) ri Notation: REVIEWER'S INITIALS: DA -TE: Kermit Center Use Only. CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fir, ' i Ping ❑ PW ❑ Documents/routing slip.doc 2-28-02 Contractors or Tradespeople P ter Friendly Page General/Specialty Contractor A business registered as a construction contractor with LitI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address 9630 153Rd Avenue Ne License No. MERITMI163CM Suite/Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2015 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY & DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.0001/20/2010 10/22/2012 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.0001/12/2009 10/25/2011 8 TRAVELERS CAS & SURETY CO 0815103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.00 03/07/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 28 Travelers Property Cas Ins Co VTC2JC0828K6148TIL12 11/01/2012 11/01/2013 $2,000,000.00 10/22/2012 27 Travelers Property Cas Co of A VTC2JC0828K6148TILL1 11/01/2011 11/01/2012 $2,000,000.00 10/25/2011 26 LEXINGTON IINS 014180670 11/01/2010 11/01/2011 $2,000,000.0010/29/2010 25 LEXINGTON IINS 049159165 11/01/2009 11/01/2010 $2,000,000.0011 /02/2009 24 LEXINGTON INS CO 004052434 11/01/2008 11/01/2009 $2,000,000.0011/04/2008 23 NSEE AMERICAN HD0G23734941 03/03/2008 03/03/2009 $2,000,000.0003/10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.0010/31/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 07/24/2013 LEGEND COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS AIR FLOW, DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN AIR NUMBER INDICATES CFM QUANTITY CD 100 EG 100 SLSM FC 911111 SUPPLY AIR NUMBER INDICATES CFM QUANTITY EXHAUST AIR, NUMBER INDICATES CFM QUANTITY SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SFD COMBINATION FIRE AND SMOKE DAMPER. T FD FIRE DAMPER SD SMOKE DAMPER 1 VD VOLUME DAMPER MD MOTORIZED DAMPER TURNING VANES VD ROUND TO ROUND 45° FITTING SQUARE TO SQUARE 45 FITTING SQUARE TO ROUND 45° FITTING 45° FITTING GAS PIPING GENERAL NOTES FOR DUCTWORK DIAMETER ABOVE ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ACCESS PANEL BELOW FLOOR BELOW FINISHED CEILING BOTTOM CEILING DIFFUSER CUBIC FEET PER MINUTE CEILING GRILLE CAST IN ' PLACE CEILING CONC CONCRETE CONN CONNECTION CTG CEILING TRANSFER GRILLE DB DRY BULB DIA DIAMETER DIFF DIFFUSER DN DOWN DWG DRAWING EA EACH EAT ENTERING AIR TEMPERATURE ENT ENTERING EQUIP EQUIPMENT ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH ` EXHAUST FLR FLOOR FPM FEET PER MINUTE FT FOOT OR FEET FUT FUTURE GALV GALVANIZED GR GRILLE HP HORSEPOWER HT HEIGHT HVAC HEATING, VENTILATION AND AIR-CONDITIONING HWG HIGH WALL GRILLE HWR HEATING WATER RETURN HWRR HEATING WATER REVERSE RETURN HWS HEATING WATER SUPPLY HWTG HIGH WALL TRANSFER GRILLE INTERNATIONAL BUILDING CODE INSIDE DIAMETER/DIMENSION INVERT ELEVATION INTERNATIONAL MECHANICAL CODE INCHES IN WG INCHES WATER GAUGE LBS POUNDS LIN DIFF LINEAR DIFFUSER LIN FT LINEAR FOOT OR FEET LWG LOW WALL GRILLE LWft LOW WALL REGISTER MAX MAXIMUM MBH 1000 BRITISH THERMAL UNITS PER HOUR MD MOTORIZED DAMPER MIN MINIMUM MTD MOUNTED NC NORMALLY CLOSED NO NORMALLY OPEN OR NUMBER OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMTER/DIMENSION OSA OUTSIDE AIR PCF POUNDS PER CUBIC FOOT PH PHASE POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR REG REGISTER REQ'D REQUIRED RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER 2009 WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416.3.4. AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER 2009 WSEC SECTION 1416.3.4. LEGAL DESCRIPTION TAX PARCEL #: 920247-0010 WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) BUILDING OWNER WESTFIELD PROPERTY TAX DEPT BUILDING INFORMATION CONSTRUCTION TYPE: OCCUPANCY TYPE: REINFORCED CONCRETE COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN. DAMAGES THEREFORE. RELIEF AIR REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE SUPPLY AIR SOUND LINED SMACNA SHEET METAL AND AIR-CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SQ FT SQUARE FOOT OR FEET SYM SYMBOL TDH TOTAL DYNAMIC HEAD TG TRANSFER GRILLE TOT TOTAL TIP TYPICAL UNO UNLESS NOTED OTHERWISE UPC UNIFORM PLUMBING CODE VTR VENT THROUGH ROOF W WATTS OR WIDTH W/ WITH W/O WITHOUT WB WET BULB WG WATER GAUGE WSEC WASHINGTON STATE ENERGY CODE SEPARATE PERMIT REQUIRED FOR: 0 Mechanical L Electrical arPlumbfrig gs Piping City of Tukwila BUILDING DIVISION J J w z w 0 0 0 TUKWILA WA, REVISIONS No Changes shall be made to the scope of work without prior approval of Tukwila Budding Division. NOTE Revisions will require a new plan submittal and may include additional pian review fees. MERIT MECHANICAL INC. MECHANICAL SCOPE 1. COORDINATE ALL NEW UNITS WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. ALL LINE VOLTAGE WORK SHALL BE BY ELECTRICIAN. GENERAL LEGEND NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES 111111111111IIIII FLEX DUCT EQUIPMENT TAG TYPE -EQUIPMENT TAG NUMBER DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN SECTION LETTER -SHEET NUMBER. WHERE SECTION IS SHOWN crz) A REVISION CLOUD AND CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE POINT OF CONNECTION TO EXISTING OR TO OTHERS WORK THERMOSTAT OCCUPANCY OR CARBON MONOXIDE SENSOR REPLACE 1 EXISTING SPLIT SYSTEM CONDENSING UNIT WITH NEW. 9630 153RD AVENUE NE REDMOND, WA 98073 24 FAX 867- (425) 0962 LICENSE: MERITMI163CM FI OPY Penult it No. Pl to review approval is subject to errorsand oIlsslof s. L1- -rc.' j of construction documents does not authorize tIi .3 boli of any adopted code or ordinance. Receipt of droved Field conditions is REVISIONS 0. FOR PERMIT 07-02-2013 TAG. MAKE & MODEL DESCRIPTION COOLING, MBH REGRIG. PIPE OUTDOOR FAN SOUND COMPRESSOR TOTAL EER LIQ. SUCT. FLA DRIVE d BA ELECTRICAL TYPE VOLT PH MCA MOCP WEIGHT LBS REMARKS CU -4 TRANE TTA090A3 NOTES: CONDENSING UNIT 88.5 10.3 1/2 3.1 DIRECT 88 SCROLL EQUIPMENT MAY BE SUBSTITUTED ` FOR EQUAL OR BETTER MANUFACTURER. LOW/HI PRESS SWITCH, CRANKCASE HEATER, REFRIGERANT R-22. 300 1, 2 RECEIVED CITY OF TUKWILA JUL 0 3 2013 DESIGNED CHECKED DATE VTD JH 06-18-2013 JOB NUMBER 813328. SHEET TITLE COVER SHEET SHEET NUMBER M 0 . 01 1—OF-2 11' EQUIPMENT PAD PARTIAL ROOF PLAN SCALE: 1/4" 41-15/16"' co M EDSCALE: NONE DIMENSIONS FOR CU -4 (UNIT HEIGHT 39-3/16") ce Et W Z W 0 2 0 (/) • • \OR3STOM • 1340' MACY"S TUKWILA PARKWAY 6' : TALL PARAPET: • SEAFOOD CITY O oe SEAPS JC PE\\Y STRANDER BOULEVARD SITE PLAN SCALE: 1/128 = 554'-11- 1' .REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL- 2 2 2013 City of Tukwila BUILDING DIVISION (3- 12z RECEIVED CITY OF TUKWILA JUL 0 3 2013 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND . TO OBTAIN DAMAGES THEREFORE. J J W 0 .1- W CL. V Q _ CD 1- 0 0 V CA Q CC J CO La. H W WA, 98188 0 MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND,' WA 98073 (425) 883-9224 FAX (425) 867-0962 LICENSE: MERITMI163CM REVISIONS 0. FOR PERMIT 07-02-2013 DATE 06-18-2013 JOB NUMBER 813328 SHEET TITLE PARTIAL ROOF & SITE PLAN SHEET NUMBER M1.00 2-0E-2