Loading...
HomeMy WebLinkAboutPermit M13-124 - JORGENSEN FORGE - REPLACE HEAT PUMPJORGENSEN FORGE 8531 EAST MARGINAL wys M13-124 City ofirukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0001600023 Address: 8531 EAST MARGINAL WY S TUKW Project Name: JORGENSON FORGE Permit Number: M13-124 Issue Date: 07/30/2013 Permit Expires On: 01/26/2014 Owner: Name: JORGENSEN FORGE CORP Address: C/O DOUG JAMES , 8531 E MARGINAL WAYS 98108 Contact Person: Name: Address: Email: Contractor: Name: Address: JESSICA BRUCE 3602 S PINE ST , TACOMA WA 98409 JESSICAB@ASEI.WS Phone: 253-572-9484 AIR SYSTEMS ENGINEERING INC Phone: 206 628-9484 909 S 28 ST , TACOMA, WA 98409 Contractor License No: AIRSYE*229KN Expiration Date: 02/01/2014 DESCRIPTION OF WORK: REPLACE ONE EXISTING 3 TON UNIT WITH ONE 3 TON CARRIER PACKAGED HEAT PUMP UNIT WITH ECONOMIZER Value of Mechanical: $8,476.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $299.25 International Mechanical Code Edition: 2012 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this • emit. �- Signature: _.__ .1 I x.11 4 l Print Nam ( ) / CA✓1 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. .L.n IRAr AH/1 M11_194 Printed 07-3n-2013 PERMIT CONDITIONS Permit No. M13-124 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-124 Printed: 07-30-2013 •• CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ............................................ _... ............................................... Project No. ...._..................... _........ 7 Date Application Accepted: (0-1 3 Date Application Expires: t 1 0 '-(!� (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 000160002309 Site Address: 8531 E Marginal Way S 98108 Suite Number: Floor: Tenant Name: Jorgensen Forge PROPERTY OWNER Company Name: Air Systems Engineering Name: acy9coscilR)%g6 Address: 8531 E Marginal Way S City: Tacoma State: WA City: Tukwila State: WA Zip: 98108 CONTACT PERSON person receiving all project communication Name: Jessica Bruce Address: 3602 S Pine St City: Tacoma State: WA Zip: 98409 Phone: (253) 572-9484 Fax: (253) 383-6337 Email: jessicab@asei.ws New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Air Systems Engineering Address: 3602 S Pine St City: Tacoma State: WA Zip: 98409 Phone: (253) 572-9484 Fax: (253) 383-6337 Contr Reg No.: AIRSYE*229KN Exp Date: 02/01/2014 Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Replace one existing 3 Ton unit with one 3 Ton Carrier Packaged Heat Pump Unit with Economizer. 8,476 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric 0 Gas ❑ Other: H:Wpplications\Porms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh -)/S Page 1 of 2 1 r Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace 1 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler 1 Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERI\1IT APPLICATION!' NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Signature: RIZED GENT: Print Name: 1Jillian D Hamilton Mailing Address: 3602 S Pine St H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 07/08/2013 Day Telephone: (253) 572-9484 Tacoma WA 98409 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0001600023 Permit Number: M13-124 Address: 8531 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 07/10/2013 Applicant: JORGENSON FORGE Issue Date: Receipt No.: R13-02092 Initials: User ID: WER 1655 Payment Amount: $299.25 Payment Date: 07/10/2013 10:04 AM Balance: $0.00 Payee: SANDRA COLYER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 09893G ACCOUNT ITEM LIST: Description 299.25 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 239.40 000.345.830 59.85 Total: $299.25 a...... o....,.;..� nc Printed. 07-10-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 M( -/2� PrQjec-t: l r° �i s� �,. �f� Type of Inspection: ; 1\-) A. 1 Alt t G -el Address: 3 I E. it r(:,J -L-- Date Called: Special Instructions:. i? e ) (A (•,-:...3 (A.� f.) ,i-' QcA. f (/7 ,j (.11:7 N / - Date Wanted: 5 - 2,3 - .` p.m. Requester: Ph2 e, 3- d s,, 2 I� l 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A-► • 4 In{pector: Dated ,Z5 /3 REINSPECTION FEE REQUIRED Prior to next inspection. fee must be paid at 6300 Southcenter Blvd./Suite 100. Call to schedule reinspection. Pcs FILE COPY1111 Structural, Solutions aemmitiMet Seattledill, first Avenue, Suite 620 -Seattle. W'A 9810'1 • tel: 206.292.5076. T coma 1250 Pacifii: Avenue, Suite 701 • Taeonla, WA 98102 • tel: 253.3,83.2797 wWw.l')CS-st rUCtural.$etit STRUCTURAL CALCULATIONS FOR JORGENSEN FORGE MECHANICAL ROOF TOP UNIT SUPPORT 8531 EAST MARGINAL WAY TUKWILA, WASHINGTON PREPARED BY PCS STRUCTURAL SOLUTIO JULY 3, 2013 13-403 M13� I2/1 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 7.4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 0 2013 PERMIT CENTER MECH. UNIT ' /MEGH. CURB ADAPTER - ATTAGH TO EXIST. GURB IN/ SALV. #10 SCREWS AT 12" O.G. EXIST. CURB SECTION 511 10=11_00 EXIST. SHT'G EXIST. I-JST - L '1 1 V I I 1 • ISM Jorgensen Forge . he Lab Heatpump Replacement. , HVAC as Roof Plan, Sobeduleo 11-114-111111 L T %M.. 11 Mei IHV a 1 11 lit ; PCS Structural Solutions Job Number = 13-403 Date = 3-Ju1-13 Name = LAH Design Criteria = ASCE 7-10, IBC 2012 Unit Weight, Wp = 600 ib + Existing Unit Weight = 0 Ib Roof Dead = Roof Snow = 15 psf 25 psf Project = Jorgensen Forge - Tukwila, Washington 2os> r G..w'19 ri --- . L - 3. '1 , 0rl W' µ Lateral Analysis: The new unit does not have a significant impact to the building's capacity to resist wind or seismic forces Check Seismic Forces (Ultimate): ASCE 7 Eq 13.3-1 ASCE 7 Eq 13.3-2 ASCE 7 Eq 13.3-3 Fp = 0.4*Sps*(Ip/Rp]*ap*Wp*[1+2*z/h] = 277 Ib 4--- GOi Tg°f- 5 Fp max = 1.6*Sps*Ip*Wp = 960 Ib Fp min = 0.3*Sos*Ip*Wp = 180 lb Z )4'(7.1-1°) 742 #1 SDS = 1� , ASCE 7, Table 13.6-1 ap = 2.5 �0 = �,�,� .. �9° . toils S ASCE 7, Sec. 13.1.3 Ip = 1 _ # ASCE 7, Table 13.6-1 Rp= 6.5 .0 Z7% /.1 .. 69 -, height of attachment z = 20.0 ft U 5 - (f) �� -�. 13oc.T $ total of height of bld'g h = 20.0 ft 'arYJThr r^1 �I r u i `' - ca (x-0 -r'z.M '.I •-o'� i -r T o -r4 l./7N 61 ',: 5 o� JZ �1r1 5urt'�..5 Xxlsr � 5r2IdtUtu e � Ca 12,,),t. , .i GHe�k k vF W6 fZbb H3010(1 ➢L ISI" S 30iST e on O C ir- o w- 5ppfc SL 13/11 1312 C.-) d„ /� 1.I5# er J %5)11:101rdr I I=o UPA^ VA” I41 M R -k- ZilSo't /< 3s 45" 6 z-, -z- 115,5 - /I ' s 10 ib''''k' 351 h-.10 165.1,4 0r1 A S } r'r" I .5mr114-t3 ���'� 12i9,arMrrfL 2 -JOIST Project: Jorgensen Forge Prepared By: Unit Report For 3t Unit 06/14/2013 01:48PM Unit Parameters Unit Model: 50TCQA04AOA3-0AOA0 Unit Size: 04 (3 Tons) Volts -Phase -Hertz: 208-1-60 Heating Type: Heat Pump Duct Cfg: Vertical Supply / Vertical Return Standard One -Stage Cooling Refrigeration Coil Lines and Filters Condensate Drain Line Size. 3/4 Retum Air Filter Type: Throwaway Return Air Filter Quantity: 2 Return Air Filter Size: 16 x 25 x 2 Unit Configuration Electric Drive X13 AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 5 -Year electric heaters (STD.) 1 -Year parts (STD.) 5 -Year Compressor (std.) No optional warranties were selected. Dimensions (ft. In.) & Weight (1b.)*** Unit Length. 6' 2.375" Unit Width. 3' 10.75" Unit Height 2' 9.375" •.. Total Operating Weight: 695 Ib ••• Weights and Dimensions are approximate. Weight does not indude unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog.. NOTE: Please see Warranty Catalog 600-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50TCQA04AOA3-OAOA0 Rooftop Unit 1 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 CRHEATER101A00 3.3/4.0/4.4 kW 208/230/240-1/3-60 Volt Electric Heater 1 CRSINGLE037A00 Single Point Kit 1 Packaged Rooftop Builder 1.36 Page 4 of 10 OPTIONS: MATERIAL: 18 ga. GAL STEEL 1" 1-112L8 DUCT INSULATION (R VALUE 3.85) GASKET PROVIDED WITH CURB 14/2" ADDED.TO.EXISTING CURB O.O.. 15 3/4" I+ +I 2` 22 /8" 25 1/8.• INSULATED COVER 33 15/16" 70 7/8" 48 1/2" 3" 1y W 6OMCD SID TOLD OCCCO KR ANSI VSSAAM PU Attn: Tag: Approval: EXISTING CURB LAYOUT 47' 20'-�j z ua• I zr-� 1 20 3/16' SUPPLY .223/16" 40 /8" RETURN I 42 CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. hfvivLL`u ktY llt\i K1Y1 111 L91,- A['P01]Yti 1 INITIAL DWG I 5/7/2012 EM 40 0/16" —+{ 16' I 1 4378' ---�{ CURD MAWR Itas.1 APPROVALS . 0An 114.79 — dermis 5/7/2012 VERIFY EXISTING CURB OD 'VERIFY SUPPLY AND RETURN OPENINGS 'NOTE ANY CHANGES ' CALL WITH ANY QUESTIONS ' FAX BACK IF DRAWINGIS OK ASIS ways *Imams. it AA IMMVINOM IA MY. " +1,14.1611 I Monday, May 07, 2012 1; 52.17PM .RR. 1-7032=4000, QUOTE #: 17560 TYLER ST ?RN CDIELK RIVER. MN 55330 (753)301-7790' . (753)351.3661 .,..... 1=7032.4000 .' . .1:201 ..Q'.- 1 .m 2 AIR SYSTEMS ENGINEERING INC. • • May 22, 2013 Dean Larsen Jorgensen Forge 8531 E Marginal Way S Tukwila, WA 98108-4018 (206) 762-1100 AIR CONDITIONING SHEET METAL REFRIGERATION ELECTRICAL PROFESSIONAL ENGINEERS SERVICE & MAINTENANCE BUILDING AUTOMATION SYSTEMS Re: Lab Rooftop Heat Pump Unit Replacement Air Systems Engineering, Inc. appreciates the opportunity to provide this proposal regarding the above referenced project. Listed below is our detailed scope of work and pricing. Scope of Work: Replace (1) one existing 3 Ton unit with (1) one 3 Ton Carrier Packaged Heat Pump Unit with Economizer. 1. Provide professional engineering services to prepare necessary documents for requesting mechanical, line voltage and low voltage permits. 2. Remove existing roof top unit serving the Lab area, dispose unit to metal recycling facility and recover remaining R22 refrigerant per EPA guidelines. 3. Furnish and install (1) one new Carrier Brand 3 ton R410A refrigerant based packaged heat pump unit with economizer and properly sized secondary heat strips. 4. Fabricate and install a new sheet metal weather tight curb adapter for new unit to set on existing roof curb and adapt to the existing duct system. 5. Provide, install and program new Honeywell Vision -Pro programmable thermostat to settings prescribed by occupant's request. 6. Air balance outside air economizer to ensure proper amount of outside air is being introduced into space for ventilation utilizing in-house air balance technicians. 7. CTS. Check, test, and start new unit to ensure it is operating properly. 8. Provide Owners manual and instructions. 9. One-year warranty on all materials and workmanship provided. Total Price: $8,476 Exclusions: • Washington State sales tax. • Permit fees. • Structural modifications and roofing if necessary. • Provide lifting services to remove existing unit and set new unit in place. • Disconnect and reconnect existing electrical supply circuit with new disconnect, electrical flexible whip, and 110 volt service outlet for new unit using in-house licensed electricians. RECEIVED 1 214 CITY OF TUKWILA Are you comfortable? JUL 1 0 2013 PtHMIT CEIsr 1 EH 3602 South Pine Street • Tacoma, WA 98409 • Tacoma: 253-572-9484 • Seattle: 206-628-9484 • Fax: 253-383-6337 • www.asei.ws AIRSYE*229KN • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-124 DATE: 07-10-13 PROJECT NAME: JORGENSEN FORGE SITE ADDRESS: 8531 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �i ilding'Divislon Fire P17--') A'N\reventionA3/41— Planning Division Public Works n Structural n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07-11-13 Complete Incomplete ❑ Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: n No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-08-13 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prr Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AIR SYSTEMS ENGINEERING INC UBI No. 600099211 Phone 2535729484 Status Active Address 3602 S Pine St License No. AIRSYE*229KN Suite/Apt. License Type Construction Contractor City Tacoma Effective Date 5/15/1978 State WA Expiration Date 2/1/2014 Zip 984098197 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date CRAWFORD, KANDI K President 01/07/2010 Bond Amount COLYER, SANDRA K Secretary 01/07/2010 08358752 GEORGE, WILLIAM Vice President 01/27/2010 CRAWFORD, DOUGLAS D Vice President 01/07/2010 VIGILANT INS CO ANDERSON, CURTIS M 02/01/2008 01/01/1980 01/07/2010 ANDERSON, LORINE $12,000.0002/04/2008 01/01/1980 01/07/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 FIDELITY Et DEPOSIT CO OF MD 08358752 02/01/2010 Until Cancelled $12,000.0001/27/2010 10/23/2012 7 VIGILANT INS CO 82138376 02/01/2008 Until Cancelled $12,000.0002/04/2008 6 TRAVELERS CAS a SURETY CO 081S10353581BCN 02/01/2002 02/01/2008 $12,000.0001/15/2002 10/25/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 32 Travelers Property Cas Ins Co VTC2JC0828K6148TIL12 11/01/2012 11/01/2013 $2,000,000.00 10/23/2012 31 Travelers Property Cas Co of A VCT2JC08K648Y1L11 11/01/2011 11/01/2012 $2,000,000.0010/25/2011 30 LEXINGTON 0 CO 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/25/2010 28 LEXINGTON CO INGTONINS 049159165 11/01/2009 '11/01/2010 $2,000,000.00 11/02/2009 LE27 CO INGTON INS 004052434 11/01/2008 11/01/2009 $2,000,000.00 11/06/2008 26 ACE AMERICAN INS CO HDOG23734941 11/01/2007 11/01/2009 $2,000,000.00 10/15/2008 25 CONTINENTAL CASUALTY CO 2048527545 02/01/2007 02/01/2008 $1,000,000.0001/16/2007 24 TRANSPORTATION INS CO TCP2048527545 02/01/2004 02/01/2008 $1,000,000.0001/10/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 07/30/2013 Rooftop Package Air -to -Air Heat Pump Schedule I.D. No. I.D. No. Area Served Mfr. & Model Refrigerant Capacity Data Electrical (MCA &MOCP include Supp. Htr.) Discharge Type Min. OSA CFM Air Filters Filter Frame Factory Roof Curb Economizer Barometric Relief Damper Op. Wt. w/accy's. Notes Cooling btuh Heating btuh Fan Voltage Ph. MCA MOCP Supplementary Heater Total Sensible SEER Total HSPF CFM S.P. RPM KW Supp. Htr. Model Voltage Ph. HP Lab Carrier 50TCQA04A0A3-0A0A0 R -410A 38230 29930 13.4 35670 7.7 1,281 0.7 1200 208 1 60.1 70 4.9 CRHEATER102A00 208 1 Downflow 180cfm 2-16x25x2 Factory Adaptor Yes Yes 595 lbs. : All Economizers are fully modulating and capable of modulating in sequence with initial stages of mechanical cooling per Washington State Energy Code. Unit Curb Strap "A" Simpson A-3 �\ \ Mechanical Unit Strap "A \` Curb Adapter Existing Curb Existing Curb #8 (0.164") x 2" Screws at 12"o.c., Min (3) Each Edge, Curb Adapter to Existing Curb (2)Simpson A-35 Each Edge. (8)total. Use (4) #10 (0.183")x1" A-35 to Existing Curb, (4) #8x2" (0.164") to 2x Blocking or Framing CURB DETAIL NOT TO SCALE HP Unit New Curb Adaptor 25'-3 1/2" 21'-2" Existing Roof Curb 20'-0" Eleva, a View 1/8" = 1'-0" GENERAL NOTES 1. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.2.4.3 to Owner within 90 days of system acceptance. O&M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 1416.2.4.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air as specified in WSEC 1416.2.1 to Owner. Systems Commissioning 1. HVAC control system shall be tested in accordance with WSEC 1416.2.3.2. 2. For HVAC unit, verify that thermostat activates heating mode, cooling mode, for all available stages, and verify that fan is set to run during all occupied hours. Verify initial programming of thermostat. Verify unit operation per ASEI Start and Test Report. 3. For HVAC unit with economizer, verify that system controls activate economizer dampers when outdoor setpoint makes free cooling available, and that dampers modulate in conjunction with mechanical cooling staging per WSEC 1413. 4. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.2.5.1 and provided to owner. 5. A Final Commissioning Report per WSEC 1416.2.5.2 shall be prepared and filed with the Owner. HP Install New VisionPro Theermostat in Existing Thermostat Location and Program to Customer Parameters Install Heatpump on Existing Roof Curb Using Curb Adaptor Unit Weight = 595 lbs Curb Adaptor Weight = 115 Ib o& . an 1/4" = Thermostat Schedule I.D. No. Mfr. & Model Type Unit Served Notes Quantity T Honeywell TB8220U1003 Seven day programmable with night setback Lab Mount @ 48" A.F.F. 1 NOTE: Programmable stats are capable of 5 degree deadband and have 2 occupied/2 unoccupied schedules for seven days per week. Parcel Number: 000160-0023 No Work in Other Buildings, Typical Area of Work—,r__7 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. TOTE: Ficvisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical reriectrical fillumbing (etas Piping City of Tukwila BUILDING DIVISIO \ FILE COPY \\ N.T.S. i 1 a i Ph, r:^u,ew approval is subject to errors and omissions. k. : •:c:E of construction documents does not authorize of any adopted code or ordinance. Receipt ori lap -proved Feld Copy and ' , . $ is ac ledged: Permit No. rtr$=r��1-- By Date: 71,) 20"/'� City Of liakwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 242013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 0 2013 PERMIT CENTER Viciniy Ma3 � 43.12--24 REVISIONS APPROVED E t4J p=4 F-4 U � CCS c O GCS Cll 1-4 1 1.0 an Tukwila, WA 98108 WA 98409 AIR CONDITIONING/SHEET METAL/REFRIGERATION/PROFESSIONAL ENGINEERS/SERVICE & MAINTENANCE o �