Loading...
HomeMy WebLinkAboutPermit M13-126 - RAISBECK AVIATION HIGH SCHOOL - ALTERATIONRAISBECK AVIATION HIGH SCHOOL 9229 EAST MARGINAL wys M13-126 City #I'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 5729800020 Address: 9229 EAST MARGINAL WY S TUKW Project Name: RAISBECK AVIATION HIGH SCHOOL Permit Number: M13-126 Issue Date: 07/30/2013 Permit Expires On: 01/26/2014 Owner: Name: MUSEUM OF FLIGHT FOUNDATION Address: 9404 E MARGINAL WAY S , SEATTLE WA 98108 Contact Person: Name: GREG EDWARDS Address: 1519 WEST VALLEY HY , AUBURN WA 98001 Email: GREG@ERICKSONREFRIGERATION.COM Contractor: Name: ERICKSON REFRIGERATION LLC Address: 1519 W VALLEY HWY N STE 102 , AUBURN WA 98001 Contractor License No: ERICKRL922QE Phone: 206 510-3458 Phone: 253-333-7294 Expiration Date: 03/21/2014 DESCRIPTION OF WORK: RUN REFRIGERATION LINES FROM CONDENSER TO EVAPORATER, PRESSURE TEST, AND CYCLE SYSTEMP UPON APPROVAL. Value of Mechanical: $4,000.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $236.94 International Mechanical Code Edition: 2012 e -a Date: 7-.% 3 V- I z, I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does construction or the performa back of this permit. Signature: Print Name: resume to give authority to violate or cancel the provisions of any other state or local laws regulating rk. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: 7 30 ` 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. rinr IMC -4/1n M13-126 Printed: 07-30-2013 • • PERMIT CONDITIONS Permit No. M13-126 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rine• IMC. -4/1n M13-126 Printed: 07-30-2013 CITY OF TUIi W Community Developmillbepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.,.ov echanical Pro�ect No: Date Application Accepted: Date;Apphcation Expires D_t _ (For, ofce'use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 1 a� e Pt tAf Iv)0C( q�J> King Co Assessor's Tax No.: 5 1i- (2,SO Suite Number: Floor: New Tenant: El Yes ❑.. No Tenant Name: 1ZI�IS�.cir 6�►i PROPERTY OWNER';` Name: Address: City: State: Zip: CONTACT PERSON-- person receiving all project` communication . Name: %' a=)4-""" s C9 V�EC�. Address: i.0 U (s-701 -R� -0 SSE City ✓aatt���� �� �1 tit IX / Address: ( 51°1 w V A l A) Tukwila Business License No.: City: St te: Zinu Phone: )e.,(7,570,3,1 _g- Fax: Email(�� - ,Log -1 MECHANICAL`CON.TRACTOR,INFORMATION : Company Name: n 6k\(.ilSc�ln t� Address: i.0 U (s-701 -R� -0 SSE City ✓aatt���� �� �1 tit IX / Phone: r tr. 7tri_ k 7.a -'Fax gs- s ;33_ 17S.2_ Contr Reg No.Exp Da R1ckz R1.�196 t=am -1 L( Tukwila Business License No.: Valuation of project (contractor's bid price): $ 61/11. C 2' Describe the scope of work in detail: 2u✓\ ae�t ery k3-0 �C�� S k ,c'_ Cr-M.4cSe-►_ Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric El Gas El Other: H:\Applications\Forms-Applications On Line \20I I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <IOOk btu Furnace >100k btu of Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type . Qty;= Air handling unit >10.000 cfm of Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit" Type Qty' Fire damper Diffuser of Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu of 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEUTHOR Signature: Print Name: Q1a3 Mailing Address: ( 71J �l�M{2.1✓1� w vvl ((L1 Dater'' 6_(� Day Telephone: - S/o' 7L 4% H: Applications\Forms-Applications On Line \201 I ApplicationsWechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh City State Zip Page 2 of 2 Parcel No.: Address: Suite No: Applicant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov 5729800020 9229 EAST MARGINAL WY S TUKW RAISBECK AVIATION HIGH SCHOOL RECEIPT Permit Number: Status: Applied Date: Issue Date: M13-126 ISSUED 07/10/2013 07/30/2013 Receipt No.: R13-02239 Initials: User ID: WER 1655 Payment Amount: $189.55 Payment Date: 07/30/2013 08:53 AM Balance: $0.00 Payee: ERICKSON REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 135823 189.55 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 Total: $189.55 189.55 rinn. Ranaint-CIA Printed: 07-30-2013 • r\ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 5729800020 Permit Number: M13-126 Address: 9229 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 07/10/2013 Applicant: RAISBECK AVIATION HIGH SCHOOL Issue Date: Receipt No.: R13-02098 Initials: User ID: JEM 1165 Payment Amount: $47.39 Payment Date: 07/10/2013 11:26 AM Balance: $189.55 Payee: ERICKSON REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 182359 ACCOUNT ITEM LIST: Description 47.39 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 47.39 Total: $47.39 .r.,..• Dene inf_r1L: Printed: 07-10-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro ect: AIS3ge11 Hie g9Apo! G I i) v1 L, Type of Inspection: 1 Nil I Date Called: Address:_ 92.2R F iic;_ w1# Special Instructions: Datea ted: �i i! a�ml p.m. Requesters / c Phone 5 -- 3%/— S I �- Approved per applicable codes. QCorrections required prior to approval. .2 COMMENTS: Q. ,?e 4 - ;A) 06,-.4p/Se _ 7)1 CD 7�fi C✓ 0I� ,vim% ris,e_b ot: , 7 riNSPECTIO N FEE R QUIRED. Prior to next inspection, fee must be d at 6300 Date: Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431-3670 Permit Inspection Request Line (206) 431-2451 P oject: RAtcABEex. N -S - Type of Inspection: a6uc.ii—ice Address: C) 20/9 s As -T Yr ASR Date Called: L Special Instructions: Date Wanted: ,.7_ 31- 13 a:m. m. Requester: Phone No: oZbG0-51 0-31.4s 0 ..-,._ A \ roved per applicable codes. ElCorrections required prior to approval. COMMENTS: 0 z%,i A/94 /WO /m1,fit /i,,2). -Re fr450,-41;okil.-57--- 6.00/ ..-,._ A \ s pecto INS id Date 3 /—i 3Z ECTION FEE REQUI, ED. Prior to ext inspection. fee must be t 6300 Southcenter. Blvd.. Suite 100. Call to schedule reinspection. FILE COPY 'A.7 B.7 D.5 5 s 0 31 2 ) 122r I I rA l� Y STOR 2180 :24 I 's CHIN -TOR 51 LAUNDRY 2250 I WE S1 ST 1- 200 I J. OFFICE 2240 KITCHEN 0 2200 1`=T r SC E. be•1'-0' EQUIPMENT SCHEDULE wT WATER FILIMR3 COVVECRON ore* .21,9 oo V.. PLUMBING REQUIREMENTS NOTES 1. Oravene�. wows a':�^eaNe.w : •ad:an; ab. .,.,.e 2. Thls °"• ..ter° m 404 , 2. Al3 wM uXs NN a car* r.m2 ad pwn.n mw. n;maomnw .. and War crass edar Awe r O.m nN ]vNoe Sour. ea0 30'.mn22,b0 40, .Nal n Wlen rne0oe•.Yebren9 rates' 5. �.diRAO, ad ret draws. ream news 7. Al 1.1 water i122o. supplied 1 nawww .eF#*lapse • e.A a..,Nowt, .dr. mm�As wernsup, An to ARA r..apeon, e. MA whim de.s.rs pre..by WW, A. m1. s"'°w� wl�pmmwaa AAAam s .9.pat M.z. m.w. n.e. m..arom.C.oand .wsan. redo, maw, 9..14epa re.. aall wake .sae 11. wn.+a Awn erasnmoa men ares. and ▪ pYotc�wmrr.mmm al panels..Xo b... ...nen ad too, A4,44 we, pam.e Corr NEW. 12. traretrriC101tonv,nrentBRpanent �wnmws oabpnp.r+S.Xwm. 13. R:ar.rrnn.wa..°e.mm:s unr em®re da. dtrapepa,An.. tee Wt.. ap.ennfe canner... Under IMpOn Ira peer.. Irstall �drn9 m.nx_ eR _ .w panus a telirnT.t.4Z/": .,. Ae.° W nv Fe. pa.awn Co... on pv 1orr7 de, Rea Mad ao.alm.m.nAmp , swan rows., do 1209 newer m.r.an w Wrenn. Ile.al°. ern winc-Ar. 7. F1MNed.reA al pxmnee continents cob 02.34 AWE sternar±. 18. 2480.°w°'°mlace arra bcats,ectxrme"ap.ap°1ndn.m.�dla.n.owpn.adm PO, l0. n F.dLwin'*wenn wv. reward, lo°s.epren b AAT.' and n2SOCof ▪ mwenn Nttn Ne oeu`xf.Ys Ideclendon Yes. nnod Ino fo.a,wn V SerAeo'wuapsplesd.d44 oss Sr rn�rc4 20 Sed pN o.e Oman. A.A. Awe.* REVIEWED FOR CODE COMPLIANCE APPROVED -PLUMBING REQUIREMENT ULAN JUL 7 4 2013 City of Tukwila BUILDING DIVISION PLUMBING LEGEND r>a an teraar p,., rapt pa.. von 1 Ana We 8.49 Ara tat NM 34 RECEIVED CITY OF TUKWILA JUL 10 2013 PERMIT CENTER M 12AR ° bassetti architects 71 Cambia Serf 8dn 500 °N4402500E1 , mal)3409519 CIVIL ENOViEER lAWISCAPE .Au.rcn srWlC11n04.010NEER PCS9 an NEOUNCALa ELECTRICAL .mlunc CCRAASAM FCN▪ wow r SERNCES AR Dew 0, Aron Anwar ...wen HARDWARE Adam Cesebr9 HiOXILNE SLXJOL o�smKr.o, RAISBECK AVIATION HIGH SCHOOL 121210 FOOD SERVICE EQUIPMENT PLUMBING REQUIREMENT PLAN FS2.1 COIL DRAIN LINE DETAIL MIC.C..:11a1i ..w ICO I::111 ILII - ury v_w Q: Hr":...1":1.a ,mem, Rmemm:m' eR n TYPICAL PIPING FOR VERTICAL RISERS e.' �ma¢RATmN REMAi1m aN r 40 - 1.:71..,10 ean�ms ucs. GENERAL NOTES COIL SPECIFICATIONS F UNIT COOLER MODELS: ADT/LET 7/16 1 _15/tE- 13_7/16• 4-976 IrI.'4F I f) I.IT.I.4.1; DRAIN gFrCT110.4 PHYSICAL DATA mamas (..I SUCTION COL maSt DRAM BIT It OBS) NPVIO ln- m 3/. NRT LET AKIXL mos. (moms) mimosa+, (moms) CUL PUT UTOPIA (045,) ALTUS n -:/Y 05-1/0 1n Ga 1n• O VP CO 0/. mt I GENERALI 'REFRIGERATION' Q: Hr":...1":1.a ,mem, Rmemm:m' eR n I ELECTRICAL' - 1.:71..,10 ean�ms ucs. 1 PLUMSPIGJ TYPICAL WIRING DIAGRAM FOR OFF CYCLE AR DEFROST TIME CLOCK 15 MINUTE CYCLE SET AT 12:008.61 1200PM NOUNIED PRE -.E0 TO SM. ROST OMPIECII. SUN CAP FANS. FOR SYSTEMS A REFRIGERATION SCHEDULE scNE0DIE TAT MULTSCIRCUITED RAC1 I I it 3114211 NOTEM PROJECT NAME A.11.11. Stenael RE NTATNE: Schuh Assoclabs LOCATION. BID BY SW. MA1 Sean I CONTACT: /5551619 I COMMATMIP ARD.. OmuN MC ITEMMOOELOF PACK CONTACT: D m R1P..ee 6OfMTOF RACK. FIT VWAu.,.SOL11A COMP VOLT ITEM DESCRIPTION BTU M - COMPRESSOR CAP NP 1.71 ILA L. LI 971 GOP. FAN OEF WAN -1. Cooler n 404. 10.1 mM1 YA MAO AOTOan8EN 1.8 VMMIn Ammer MI -10 +70 FON AVISSIDECT 140 206/3 SSA ID conansarran 20R1 to 2.0 4110 UNE AMPS4 20.4 141 CONN 104 MAE 200 Vol, a Rome, eOC,.M AWarning Refrigeration Installer must have nitrogen flowing through all pipes during all weldingEs- Factory will not pay for any damages In Ma solenoid or axpanslon valva caused by scala In timer piper. WIRING DIAGRAM FAN SPEED CONTROL WIRING DIAGRAM 60Y THERMOSTAT OMNI TEMP REFRIGERATION RACK aims mr3ORUS TO UL STD 1995 ISOMET 11111100 w AI. NtIAL to RECEIVED CITY OF TUKWILA JUL 1 0 2013 ECTION VIEW s PLAN VIEW SECT,. NM CURB DETAIL DECTRKOL CONTRACTOR m ram 6FTFAENT COLORED mFES TO n06626-0 COIL AAS 9101,1 ON G PAM/. DECIRICAL SUPPLY PERMIT CENTER TUBING SEQUENCE BUT IMASualleaS API TO EE VON. ON DE .L RMS., .CIPICAL MSTIPILEANIN. MO MINT MUM IIAIE BUM LOCATED AS KWAATELY AS NO IESPOMMIUm FOR sEau OGNE Br SAID E0011ACTOAS AND mu, N07 CCM, ORCANANCPS. C.1311041. CP Br 114 9.51111/1. CA OF 0. IIIPMFICEPAN11. it IS nOl 10 BS SEPRODUMD OR ransoms. N0. RENGON 081E BY OmniTemp Restrlgeratlen Division 0107500am. Inc. 9300 Hal Road, Dawes. CA 90241 Ptone:(582)9234660 Fac (562)862-1466 Eads@ Camyteomnfeamkccan Carvallo Contractors License 1471945 Aviation High School Seattle WA_ 08-0!-11 XS 13192 SCNE None Refrigeration flan Cathy GOdinez smamaga R1 of 1 R:\o......mVm00.4w1m NIP San. (RPM.) 0na7.ay PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-126 DATE: 07/10/13 PROJECT NAME: RAISBECK AVIATION HIGH SCHOOL SITE ADDRESS: 9229 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: C Building Division Public Works 14 E Avv\ Fire Prevention Structural Planning Division ❑ Permit Coordinator E DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete lysi Incomplete ❑ DUE DATE: 07/11/13 Not Applicable Comments: Permit Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 1$ REVIEWER'S INITIALS: DATE: Structural Review Required No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 08/08/13 Approved ❑ Approved with Conditions ' " Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit°Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page ?age 1 of 2 • General/Specialty Contractor A business registered as a construction contractor with LEd to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ERICKSON REFRIGERATION UBI No. 602592091 LLC Phone 2533337294 Status Active Address 1519 W Valley Hwy N Ste License No. ERICKRL922QE 102 Suite/Apt. License Type Construction Contractor City Auburn Effective Date 11/5/2008 State WA Expiration 3/21/2014 Date Zip 98001 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTSSR881P9 WEST SEATTLE ROOFING Construction Contractor General Unused 10/29/201210/29/2014 Active ATEKAHA943U1 ATEKA HEATING Et AIR LLC Construction Contractor Heating/Vent/Air -Conditioning And Refrig (Hvac/R) Unused 3/21/2006 11/5/2008 Inactive ATEKAHA956K5 ATEKA HEATING & AIR Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 5/25/2005 5/25/2007 Out Of Business Business Owner Information Name Role Effective Date Expiration Date EDWARDS, GREGORY J Partner/Member 11/05/2008 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 American States Insurance Co 325206749 04/20/2012 Until Cancelled $6,000.00 05/07/2012 1 American States Insurance Co 6478746 11/05/2008 04/20/2012 $6,000.00 04/06/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Mid -Century d Century Ins 605041166 09/16/2011 09/16/2013 $2,000,000.0009/04/2012 3 Ohio Security Ins Co BKS53576419 03/20/2011 03/20/2012 $1,000,000.00 03/23/2011 2 OHIO CAS INS BR053576419 03/20/2010 03/20/2011 $1,000,000.0003/09/2010 1 OHIO CAS INS BR053576419 11/05/2008 03/20/2010 $1,000,000.00 02/24/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 07/30/2013 III 111 III 111 1111111 11111111111 1111 111111111111 111111111111111111 11111111111 1111111111111111.11111 111111111111111111 1 11111111111111LI111111111111 111 11[1111 111 TORAGE TOILET LAUNDRY WASHING OFFICE KITCHEN COOLER CONDENSER UNIT MODEL #ADT090 CONDENSATE LINS TO NEW COOLER EVAPOFATOR FREEZER CONDENSER UNIT MODEL #LET120 FREEZER STORAGE 1111 1I 111111111111111111111111111111111111111111111 111111111 FLOOR PLAN 3/16"=1'-0" IIIIIIIIIIIIIIII CONDENSATE LINES TO NEW FREEZER EVAPORATOR 0 e 0 0 0 0 0 0 0 1111 11111111 1111111111111 11111111111 1 COOLER CONDENSER BELOW UNIT MODEL #ADT090 FREEZER CONDENSER BELOW UNIT MODEL #LET120 LL 11 II II 11 L �L E n �fi J L J T 4 f t n I Lc-- ___ � CONDENSATE LINES TO NEW COOLER EVAPORATbR I7 -J ll I LT SEPARATE PERMIT REQUIRED FOR: 0 Mechanical plectncal robing Gas Piping City of Tukwila —BUILDING -DIVISION III I REVISIONS h�anges shall be made to the scope of work without prior approval of 1 1 Tukwila Building Division. Nc) EL Revisions will require a new plan submittal njay include additional plan review fees. I IT 1 1� 4'-10" 11 II II - - II - NEW' ROOF -MOUNTED OMNI I, TEMP REFRIGERATION RACK ITEM NO. OTA1-AC-H-2-0-3 3'-10" P.T. 4x4 x 7'-0" LONG (2 PLACES) BTWN NEW CONDENSER & ROOF r L u 4 1 T 1 L 7 ii I —JJ CONDENSA1IE LINES TO NEW FREE ER EVAPORATOR 0 O le Plan. re 'ew approval is subject to errors and omissions. &&:;,;.,raLoLconstnjction documents does not authorize th:.. tion of any adopted code or ordinance. Receipt o1 approved Fieldand , is acknowledged: i___C • FILE COPY rmnNo. rl I 3- (24' ROOF PLAN 3/16"=1'-0" 7'-O" BY Iate:7 'czN City Of lb is S 0 Z NEW ROOF -MOUNTED OMNI TEMP REFRIGERATION RACK ITEM NO. OTA1-AC-H-2-0-3 OMNI TEMP REFRIGERATION 6" RACK PLATFORM CONDENSER FASTEN ERS PER MFGR'S SPECIFICATIONS P.T. 4x4 x 7'-0" LONG (2 PLACES) BTWN NEW CONDENSER & ROOF X" THICK PROTECTIVE RUBBER MAT BTWN 4x4's & EXG ROOFING MEMBRANE EXG ROOF DIAPHRAGM 3'-10" REVIEWED FOR CODE COMPLIANCE APPROVED :7 JUL 2 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 10 2013 PERMIT CENTER \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ CONDENSER HOLDOWN N.T.S. CD o V) Q 0 W 0 y0 E 1519 W. VALLEY HWY N., STE 102 AUBURN, WA 98001 ON to M M C� csi 0_ LL DATE 04.12.13 DRAWN CHECKED KWT GE m,6 „llY SHEETxoS1 JOB NO. 13034 \\STORAGE\Data \2013\13034 AHS Cooler \Structural\S1.dwg 1 Drafter Name: K. TERRELL 1 Plot Date: APR 15 2013 09:23:49 1 Last Modified Date: APR 12 2013 14:57:16 1 Submittal: PROGRESS PRINT