Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-131 - BOEING #9-53 - ALTERATION
BOEING #9-53 9725 EAST MARGINAL wys M13-131 Parcel No.: Address: City Aukwila S Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9-53 Permit Number: M13-131 Issue Date: 08/02/2013 Permit Expires On: 01/29/2014 Owner: Name: Address: Contact Person: Name: Address: Email: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124 MARGIE DE LEON PO BOX 249 , AUBURN WA 98071 MARGIEDELEON@AUBURNMECHANICAL.COM Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA 98071 Contractor License No: AUBURMI163BA Phone: 253 838-9780 Phone: (253)838-9780 Expiration Date: 09/12/2014 DESCRIPTION OF WORK: INSTALL (2) CRAC UNITS WITH DIRECT EXPANSION COOLING COILS, ELECTRIC HEATING COIL, HUMIDIFIER WITH AIR COOLED CONDENSER, AND REFRIGERANT ECONOMIZER. INSTALL (1) EXISTING CHIT•i,FD WATER CRAC UNIT WITH ELECTRIC HEATING COIL AND HUMIDIFIER. REPLACE (1) VARIABLE AIR VOLUME TERMINAL UNIT. Value of Mechanical: 325,562.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied Fees Collected: International Mechanical Code Edition: Date: $3,642.63 2012 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre construction or the performance of work. back of this permit. Signature: Print Name: erf 14/./."1 e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: V Z "- Z /3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J--. 111AtS A/Arl Ml Z_l Z1 Printarl• nR_n7_7fl1 PERMIT CONDITIONS Permit No. M13-131 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ***FIRE DEPARTMENT CONDITIONS*** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. ion: IMC -4/10 M13-131 Printed: 08-02-2013 ns�c 20: These plans were reviewed by I for 511. If you have any questions, please c (206)575-4407. kwila Fire Prevention Bureau at a.,,.• IRAr_eil n M13_131 Printed• 08-02-2013 ilkCITY OF TUKH Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov 411 Mechanical Permit No. IV `'1171 Project No. Date Application Accepted: b S Date Application Expires: 0 l 15 L\ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 56242009900 9725 East Marginal Way S., Tukwila,WA 9810 Boeing Commercial Airplane Group Suite Number: PROPERTY OWNER Name: Margie De Leon Name: The Boeing Company City: Auburn State: WA Zip: 98071 Address: 9905 E Marginal Way S Email: margiedeleon@auburnmechanical.com City: Tukwila State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Margie De Leon Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 838-1384 Email: margiedeleon@auburnmechanical.com Floor: 1 New Tenant: El Yes ❑✓ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Auburn Mechanical Address: P.O. Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Contr Reg No.: AU -BU -RM -I164 Exp Date: 09/12/2014 Tukwila Business License No.: BUS -0100148 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Install (2) CRAC units with direct expansion cooling coils, electric heating coil and humidifier with air cooled condenser and refrigerant economizer. Install (1) existing chilled water CRAC unit with electric heating coil and humidifier. Replace (1) variable air volume terminal unit. 325,562 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑✓ Replacement 0 Fuel Type: Electric ❑✓ Gas ❑ Other: H:\Applications\Fomu-Applications On Line \2011 Applications \Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 4 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 N R OR AUTHO ZE AGENT: Signature: Date: —7/-[// Print Name: Margie"De Leon Day Telephone: (253) 838-9780 Mailing Address: P.O. Box 249 Auburn WA 98071 City State Zip H:\Applications\Forms-Applications On Line \201 I Applications \Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 2 of 2 J.(.`Nt�A wq City of Tukwila ��� chi �''J\ r 2 1908 • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M13-131 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 07/15/2013 Applicant: BOEING #9-53 Issue Date: Receipt No.: R13-02277 Initials: User ID: JEM 1165 Payment Amount: $2,914.10 Payment Date: 08/02/2013 10:30 AM Balance: $0.00 Payee: AUBURN MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0011736 2,914.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 2,914.10 Total: $2,914.10 tint• Parainf-fR Printed: 08-02-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M13-131 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 07/15/2013 Applicant: BOEING #9-53 Issue Date: Receipt No.: R13-02130 Initials: JEM User ID: 1165 Payment Amount: $728.53 Payment Date: 07/15/2013 12:40 PM Balance: $2,914.10 Payee: AUBURN MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0011721 728.53 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 728.53 Total: $728.53 rinr• Roncinf_flA Printed: 07-15-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 A1/3431 Project: &n6 9:-s Type of Inspection: f Ai --L e Address: °j 7.0 E. 416Wt-�� Date Called: . Special instructions: . Date Wanted: `a_m. 10-23 -11 p.m. itequester: Phone No: _ -73.0-0_5-40 3 4. Approved per applicable codes. Corrections required prior to approval. - COMMENTS: op/WY-to f)tre t Inspec i\„ Date: REINSPECTION FEE EQUIRED,,f ft r to next inspection, fee must be e 100. Call to schedule reinspection. paid at 6300 Southcenter Blvd.,j5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Prolect40�, / ` fl —S 3 C� Type of Inspecti eo eJA , 1. 04/ Address:re q S . AMJ(a.,. /\AL. Date('CCallllledd: Special Instructions: / Date Wanted - (� /"ate% Pam Requester: Phone No: '7.0(-`730-/3?0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 3) nS. OA AAA 12 Ner *_._n_S fl zr G *Ik t uA 5 3 At P !� LA-eK I n s,¢ector: Date: REINSPECTION FEE REQUIRE[`. Prior to next. inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3- 4--/Y-6 114/3- 131 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Pro : f}2 0 -QA 0,..) Address: Suite #: 57d -S—.— &/ / -S x_1-3 Typt_q of Inspection: A- 1/o �TJA C z Cont ct Person: Special Instructions: Phone No.: 61(,.., Approved per applicable codes. Corrections required prior to approval. COMMENTS: V4/Cc 3-- — U I� Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: /4%//,.. Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 i 1 -4 Pe ping envie i1 1 .7aiA:.7i. a. 4;prove By THE BOE//VC COMPANY SUPPORT SERVICES GROUP FIL ', r .3 -BUILDING - INTEGRATED TECHNICAL 1.3DEVELOPMENT LAB pproval is subject to errors and omissions. BOEING DEVELOPMENTAL CENTER nstruction documents does not authorize 9725 EAST MARGINAL WAY SOUTH of any adopted code or ordinance. Receipt TUKWILA WASHINGTON 98108 CODE SUMMARY DRAWING INDEX City Of'it,kwita BUILDING DIVISI FROM DOWNTOWN SEATTLE TYPE OF APPLICATION: NEW 0 ALTERATION 0 ADDITION 0 TENANT IMPROVEMENT • PROJECT DESCRIPTION: UPGRADES OF EXISTING HVAC, POWER, AND FIRE PROTECTION FOR THE INTEGRATED TECHNICAL DEVELOPMENT LAB AREA. 1) PROVISION OF TWO COMPUTER ROOM UNITS WITH DIRECT EXPANSION COOLING COIL, ELECTRIC 2)INS • .F.N TING ILLED WA COIL AND HUMIDIFIER. N WITHE 'ICH IN ARCHITECTURAL CODES AND PERMITS PROJECT TITLE: F-22/CRUS ROOM MODS JOB NUMBER: /12337259 QUANTITY SUBMITTED' ❑ 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT II 4 SETS: TENANT IMPROVEMENT (NON-STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW in BUILDING 0 GRADING ❑ PLUMBING TIE 0 LANDSCAPE ] MECHANICAL * ❑ DEMOLMON ❑ STRUCTURAL ❑ - * TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE -APPROACHES COMPLIANCE OPTION PRESCRIPTIVE 0 LPA 0 ANALYSIS 0 N/A SPECIAL INSPECTIONS REQUIRED' ❑ WELD ❑ REBAR ❑ STRUCTURAL BOLTING ❑ OTHER CALCULATIONS N/A TYPE: ❑ ELECTRICAL jlr ❑ FIRE PROTECTION 41F ❑ CANTILEVER RACKS 0 ❑ CONCRETE ❑ ANCHOR BOLTS ❑ STRUCTURAL OBSERVATION ATTACHED —(YES) — (NO) DRAWING TITLE TITLE SHEET FLOOR PLAN REMOVAL FLOOR PLAN REMOVAL FLOOR PLAN FLOOR PLAN FLOOR PLAN imurommulimmeme it tsT..veira� widavimsisimtecan: y.(pren li 'm© OWNER PROVIDED IT UPGRADES. 4) UPGRADES OF THE FIRE DETECTION AND FIRE SUPPRESSION SYSTEMS SERVING THE SPACE. 5) PROVISION OF AN AIR DAM IN UNDERFLOOR SPACE 6) PROVISION OF CONCRETE PAD FOR OUTDOOR MECHANICAL EQUIPMENT . CODES: 2009 INTERNATIONAL BUILDING CODE & WAC 51-50 2009 INTERNATIONAL MECHANICAL CODE & WAC 51-52 2009 INTERNATIONAL FIRE CODE & WAC 51-54 CURRENT WASHINGTON STATE ENERGY CODE WAC 51-11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER: THE BOEING CO. BOELNC * 294ML(OV2009) BOEING PROJECT ENGINEER' THOMAS HANSON, AIA AT 206-947-4880 BOEING CONTACT: JOHN MURDOCH FAX NUMBER- 253-773-0119 john.s.murdochOboeinp.com E-MAIL; ZONING: 09-53-1A283 09-53-A506 09-53-A507 09-053-1E11 PARTIAL 1ST FLOOR 480Y 27 REMOVAL PLAN 09-053-1E2 09-053-1E514 1ST FLOOR 480 270 POWE OWER PLAN Mt•M.1-1060.$ S S S S S r}�nx$44 rt1� n4-m*-4!trA�a mn. 10 .-i •3-E•5:1: *sN © 4 0 - 3-E 4' Ita :1 CTO S DRAWING NUMBER 09-53.1-1 S63 09-53.1-1 REV D G TITLE C FIRST FLOOR SLAB PLAN FIRST FLOOR SLAB PLAN SECTIONS AND DETAILS PHONE' 253-773-0444 DRAWING NUMBER REV 9-53.1-1E263 9-53.1 -E531 MECHANICAL OCCUPANCY GROUP- GROUP B1 BUSINESS CONSTRUCTION TYPE- TYPE II -B ALLOWABLE AREA INCREASE- SPRINKI FRED & 60' SFT -RACK (NO CHANGES) DRAWING NUMBER DRAWING TITLE OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA: (ACTUAL) NO CHANGE (TABLE 10-A) OFFICES OCC BLDG GROSS 97.901 SF SO FT STORAGE OCC TUNNEL SO FT LABORATORY OCC FIRST FLOOR 54.821 SF SO FT CANOPY OCC 1ST FLR MEZZ - SO FT OTHER OCC 2ND FLOOR 43,080 SF SO FT 2ND FLOOR 1AE77 SO FT PROJECT AREA 1ST FIR 1454 SF SO FT /: Et!! 'r1r. r v1i:=D F Mechanical lectrical lumbing as Piping BUILDING HEIGHT: (ACTUAL) 44 FT STORIES: 2 MEZZANINE ? 0 (YES) • (NO) SO FT FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 ? . (YES) ❑ (NO) PAST MWOJN•. WAY ODAPORAIE PNM 599 TUKWILA FROM KENT & AUBURN DEVELOPMENTAL CENTER SEPARATION EXTERIOR WALL (NON-BEARING) HOUR RATING EXTTERIOR WALL (BEARING) HOUR RATING IMERK.0"0,66.4.'n.i 1TATNVCI HOUR RATING INTER R WALL (BEARING) pc����� SIRU RALDEMOrTABLE��1@P�AL';;R1ETITIONSS R.EVISJQ aT-ING FLGOrdCEIUNC-rD c an¢PS shall be rt_3_u(7g Tr 1 ROOF CONSTRUCTION � T 1t'.17lt without prior approval o SEISMIC. DESIGN: ZONE ' i lila Building Division. D£SIGNIL arlR hvisions will requipe)a.n FR1c00 `IA Lsfl J may include ad. •) '' nal �f, 09-53.1-1M1 3R 09-53.1-1 M 14R 09-53.1-M2 09-53.1-1M13 0'- 31-1 •4 9- . - 1 09-53.1-1M114 09-53.1-M311 FIRST FLOOR HVAC PLAN - NORTH FIRST FLOOR HVAC PLAN - SOUTH HVAC LEGEND PIPING LEGEND MECHANICAL GENERAL NOTES FIRST FLOOR HVAC PLAN - NORTH 9-53.1-E538 SMOKE DET BILL OF MATE EQUIPMENT LO AIR SAMPLING N ON PLAN & DETAILS VESDA SYSTEM PIPI CO2 PIPING DETAILS & SYSTEM WIRING DETAILS SYSTEM WIRING DETAILS FR F O.R . •I•I G P, - Si 09-53.1-M360 09-53.1-M361 09-53.1-M450 09-53.1-M451 MECH/STOR ' STAIRS (PSE) CONCENTRATED WIND: EXPOSURE 80 MPH. EXPOSURE C 40• •L - FIRST FLOOR PLUMBING PLAN - SOUTH DETAILS - MECHANICAL CITY OF TUKWI . ' OF TUKWIL SCHEDULES SCHEDULES ENLARGED PLAN MECHANICAL SECTION 09-53.1-M506 IIMI PIPING DETAI S imrineat --imminor.M:I , 1 ■ a •11U�1 ��i�7 . , i PERMIT CENTER FOR CONSTRUCTION PROJECT TITLE: INTEGRATED TECHNICAL DEVELOPMENT LAB JSF VIRRUL REAL TRAINING AREA COVER SHEET 9-12061 06.20.13 J/784654-00 CAS - INSTALL WALLS FOR UCAV J/523331-08 NEW WARFARE OFFICE NCO LAB TO 9-53 J/120573-00 J#120110-00 E 9-532 F-22 TRMNING AREA 10.06.98 09 10.02 08.12.03 INSTALL SUSPENDED CEILINGS F-22/GINS ROOM MODS J11067207 /12125341 /12337259 INTEGRATED TECHNICAL DEVELOPMENT LAB DEVELOPMENT IAB - IFC WH_12058 5118 TIM 10.07.09 N DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WV CEL 06.20.13 BUILDING 9-53 ARCHITECTURAL MASTER COL. G1 12125341 9 -53 -Al 230 CF (TYP (8"NECK) Co 700 1)0 Itq 1 250 CFM(4 8"NECK) 750 CFM TYP 1) 1M451 :;FM 1M13 26/16 UP 36/24 UP 26/4 270 CFM fYP fl26 141 n 28/24 48/20 10/10 400 CFM 150 CFM (TYP 10 CCI (BB.5 LEGEND CRAC COMPUTER ROOM AIR CONDITIONING UNIT CW DOMESTIC COLD WATER GENERAL NOTES 1. SOUND -UNE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. • [% SECURE PENETRATION. SEE DETAIL W> SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. L5 % SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL �E6REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 9 4 2013 AA.5 City of Tukwila BUILDING DIVISION 600 CFM I-' 180 CFM \, (TYP 5) 700 CFM (Tr 14/9 "FH 725 CFM H 100 CFM (TYP 10X8 150CFM CD (TYP ) 2 FIRST FLOOR PLAN - NORTH RDA RENTSCN CN K DEVELOPMENT LAB - IFC WH_12058 L DEVELOPMENT LAB - ECN-01 WH_12058 C RECORD DRAWING D REEFED 4 EXIST. DIFF. 0 CC -5.5 E RELOC NCO LAB 9-12061 170051 12011000 RI WH VAT AOC RAD RWS DAP SIM REW03N CV CEL pawn RWS RWS 04.01 13 06.20.13 C 8.30.91 08.27.03 ADD DETAIL 1/10451 MODIFY 8R&T COMPUTING LAB INSTL DROPPED CEILINGS RMS 12883 & 11064 DEVELOPMENT LAB - 50S IFR WH_12058 DEVELOPMENT LAB - 90S IFR WH_12058 9686868 10697207 10428-10 81 HARR 14.WONC HARR WH WH NIPRENED RWS CV CV D41E 01/27/10 06.17.10 09/07/11 06.22.12 07.12.12 prasw-,Arde. ACCEPTABILITY 1HIS DESIGN AND/OR SPECff1CATKIN IS APPROVED BY DEPT. L. ET AppBO,,FD D. MEYER ENbWEEN DATE D. MEYER RECEIVED �? CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER TYP M501 TYP I 5D1 TYP I M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CIN TR C ON NATE REMOVAL REMOVE EXISTING DIFFUSERS, GRILLES, AND TERMINAL UNIT, CONTROLS AND ASSOCIATED DUCTWORK. CAP DUCTWORK AT THE BRANCH TAKE -OFF. PROVIDE NEW CEILING TILES TO MATCH THE EXISTING AT LOCATIONS WHERE DIFFUSERS AND GRILLES ARE REMOVED. FOR CONSTRUCTION (DATE © �O o OO003©0.6 0 i ■II■U■1 W 11.11111.111111.1111111. INF _■■_._■■■■■_ - ---IiEl -ILI----M■■NI• KEY PLAN NOT To SCALE 8 4 0 2 4 16 -— -— SCALE: 1/8• = 1'-O" SURTTRL FIRST FLOOR HVAC PLAN - NORTH CURRENT RE`ASION 9-12061 I L AE 06.20.13 CHECK D K. RAMSEY APPROVED K. RAMSEY LUW APPROVED 5.17 90 TRE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/1-6 DEV. CENTER, WA 1M13R JDR No. 89065 COUP NO. ONG No. 9-53,1-1M13R 26/14 UP 36/24 UP 22 CFM IFF • �1� 26 14 " PAM' 114 14/12 0 14/8 14 12 36/24 CD SEE ANSFER DUCT DETAIL 230 CFM (TYP 3 10x8 150 CFM TYP ) 12/16 40/24 24/24 C)115:714 0P 24 20 CII ■ 24/14 C) y 118/14 f% 14/12 Cc (BB.5 290 CFM (•a CONFEREN 150 CFM TYP 600 CFM 850 CFM (2 TYP) 230 CFM TYP 9 OFFICE 10/10 305 CFM TYP 195 CFM (TYP MATCHLINE - SEE SH BE (AA.5 UT1 OFFI OFFICR 305 CFM (TYP 180 CFM FIRST FLOOR PLAN - SOUTH I II II II I II II II II II II II JI IL JI IL SYN RENSION BY W'PROAD DATE SYN REVEEIN BY APPRDIED DATE A RECORD DRAWING MJC KMR/RB 8.30.91 F DEVELOPMENT LAB - IFC WH_12058 WH GV 07.24.12 B MOVE THERMOSTAT D1321848 SLB RAS C RELOCATE NCO LAB 12011000 RWS RWS 08.28.03 D DEVELOPMENT LAB - 50% IFR WH_12058 WH GV 06.22.12 E DEVELOPMENT LAB - 90% IFR WH_12058 WH GV 07.12.12 BOE,AIG® LEGEND GENERAL NOTES 1. SOUND -LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON•SHEET M3. 13 > SECURE PENETRATION. SEE DETAIL 14 > SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. 15 > SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. TYP IM501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES REMOVE EXISTING DIFFUSERS, GRILLES, AND TERMINAL UNIT, CONTROLS AND ASSOCIATED DUCTWORK. CAP DUCTWORK AT THE BRANCH TAKE -OFF. PROVIDE NEW CEILING TILES TO MATCH THE EXISTING AT LOCATIONS WHERE DIFFUSERS AND GRILLES ARE REMOVED. REVIEWED FOR 'CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION. REMOVAL FOR CONSTRUCTION DATE SUBTITLE LDEWAT THIS EAND/OR FIRST FLOOR HVAC PLAN - SOUTH SPECIFICATION IS APPRMED D. MEYER SHEET ,L .1O,.VED BY DEFT. -.F W. 2N�w�Er TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB 1 M14R BUILDING 9-53.1 D CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER O 0 00006 KEY PLAN NOT TO SCALE 8 4 0 2 4 16 Mill IMO SCALE: 1/8' = 1'-0' CURRENT REVISION 5YM801. DATE 9-12061 F 07.24.12 K. RAMSEY APPROVED K. RAMSEY L LAW JOB NO. D1321848 COMP NO. 5.17.95 MECHANICAL MASTER COL. A-CC/6-11 DEV. CENTER, WA DEC No. 9-53-1M14 V EC HA\ I CAL HVAC L -CE\D GENERAL SYMBOL DESCRIPTION OT RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 4. 24x12 1 1_ 24,12 24.121 V��1 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST ROUND DUCT, NUMBER INDICATES DIAMETER 5 240 i 1_11__? OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER 24.120 9 24120 . i i PRESSURE SENSOR AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS XSUPPLY ilDBSUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY WH CV EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS smir/); INEW'/2 EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY Q1_ Z --`J DEVELOPMENT LAB - IFC WH_12058 EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS I I i V 07.24.12 EXHAUSTUAREOR AIR OCRECTANGU, RETURN AIRELBODUWCT, SQLAR FACING AWAY I= TRANSITION RECTANGULAR TO RECTANGULAR HEEL TAP OR LOW LOSS TRANSIHON AT TAKE OFF FROM OVAL TO ROUND OR ROUND TO ROUND Q 1 K I f=11C1-i 1 TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL 1 4 CONICAL SPIN -IN W/ VOLUME DAMPER (NOT SHOWN) YYY i 1 Y DUCT OFFSET UP OR DOWN N OPPOSED BLADE DAMPER rinPARALLEL BLADE DAMPER 1-L-14" J1 VOLUME DAMPER DUCT DAMPER, MOTOR OPERATED (ELECTRIC) BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) NM -� BDD AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) ' 5141 ' .1- RECT GU NG DVANESSQUARE ELBOW ME RECTANGULAR DUCT, LONG RADIUS ELBOW SIDEWALL SUPPLY AIR GRILLE OR REGISTER r-, CEILING DIFFUSER FLEXIBLE DUCT GENERAL SYMBOL DESCRIPTION SUPPLY AIR FLOW DIRECTION, POSITIVE PRESSURE RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION, NEGATIVE PRESSURE GENERAL SYMBOL DESCRIPTION OT TEMPERATURE SENSOR, WALL 111 THERMOSTAT, WALL OH HUMIDITY SENSOR © CARBON DIOXIDE SENSOR, WALL 0 OCCUPANCY SENSOR P. DUCT TYPE SMOKE DETECTOR © PRESSURE SENSOR © PRESSURE SENSOR HIGH/LOW LIMIT DIFFUSER AND GRILLE CALLOUTS SUPPLY GRILLE, MARK SG SG -200 DESIGN CFM, SEE SCHEDULE FOR DIFFUSER AND GRILLE NECK SIZE, TYPICAL CD -CFM = CEILING SUPPLY DIFFUSER FSD-CFM = FLOOR SUPPLY DIFFUSER SG -CFM = SUPPLY GRILLE ABBREVIATIONS ABBREVIATION DESCRIPTION A AAV AD ADD AF AFF AMS AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTUH BW C Cy 'C CAP CC CCW CFM CI CO COMB CONN CONT COTG CPLG CRU CRAC CW DA DB DBD DEG . DI DIA 0 DIM DL DN DS DWG dB DP FA EAT EDC EFF ELL ELEC ELEV, EL ENT ESP ETP EVAP EWT EXH EXIST EXT 'F FC FD FLR FCO FOB FOF FOIC FOT FPM FPWH FS FT FV FW GAL GPM GALV GA GCO ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR AIR MEASURING STATION ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CLEANOUT COMBUSTION CONNECTION CONTINUED/CONTINUATION CLEAN OUT TO GRADE COUPLING COMPUTER ROOM UNITS COMPUTER ROOM AIR CONDITIONING UNITS DOMESTIC COLD WATER DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DEGREES DUCTILE IRON DIAMETER DIMENSION DELUGE DOWN DOWNSPOUT DRAWING DECIBELS DRY PIPE EXISTING EXHAUST AIR / EACH ENTER AIR TEMPERATURE ('F) EVERETT DELIVERY CENTER EFFICIENCY ELBOW ELECTRICAL ELEVATION ENTERING EXTERNAL STATIC PRESSURE ELECTRONIC TRAP PRIMER EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FREEZE STAT FORWARD CURVE WHEEL FIRE DAMPER, FLOOR DRAIN FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FREEZE PROOF WALL HYDRANT FLOW SWITCH, FIRE SPRINKLER (WET PIPE) FEET FACE VELOCITY FPM FIRE WATER GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE GRADE CLEANOUT ABBREVIATIONS ABBREVIATION DESCRIPTION HC HD HORIZ HP HPC HR HVAC HPU HTG HW Hz D GV NSUL N NSTAN NT KW KVA LAT LBS, f LVG LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NEC NIC NO NTS NPSH A BD CC S&Y D VHD BD D/AP DI 1/ LS OC OS RESS RV S SIG SV RA ECT EF EV H M OT PM PBP OD TN SA SAN SCFM SG SHC SHF SHT SO SOV SP SPEC SQ SS STL STRUC SW SUCT HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING DOMESTIC HOT WATER HERTZ NSIDE DIMENSIONS NLET GUIDE VANE NSULATION NCHES NSTANTANE0US NTERMEDIATE KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE CO POUNDS LEAVING LEAVING WATER TEMPERATURE ('F) MIXED AIR MAXIMUM BTU PER HOURX 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NATIONAL ELECTRIC CODE NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OCCUPANCY SENSOR OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PUMPED CONDENSATE DRAIN PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POST INDICATOR VALVE DUCT PRESSURE LIMIT SWITCH POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER REQUIRED RETURN SUPPLY AIR SANITARY SEWER CUBIC FEET OF AIR, AT STANDARD CONDITIONS SUPPLY GRILLE SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SHEET SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SPECIFICATION SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD, SITE WATER SUCTION SYN REVISION BY APPROAED DATE SYM REVISION BY APPROVED DALE - DEVELOPMENT LAB - 50% IFR WH_12058 WR GV 06.22.12 A DEVELOPMENT LAB - 90% IFR W11_12058 WH CV 07.12.12 B DEVELOPMENT LAB - IFC WH_12058 WH CV 07.24.12 BOER/ ACCEPTABILITY TMS DESIGN 210/OR SPEORCATXKI IS APPROVED 'MELTED DATE ABBREVIATIONS ABBREVIATION DESCRIPTION TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP V VAV VD VP VERT VTA VTR ID IE W WB WG WCO WS WSEC WH WHA TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE, TRAP PRIMER TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL VENT VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF INSIDE DIAMETER INVERT ELEVATION WASTE WET BULB TEMPERATURE WATER GAUGE WALL CLEAN OUT WET STAND PIPE WASHINGTON STATE ENERGY CODE 2009 WATER HEATER WATER HAMMER ARRESTOR REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 20:3 PERMIT CENTER FOR CONSTRUCTION SUBTIRE HVAC LEGEND CURRENT REMSKNI 9-12061 SYMBOLB DATE 07.24.12 APPROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SHEET M1 .LOB NO. 9-12061 COMP NO. DWG NO. 9-53.1-M1 MIECHA\ICAC PIPJ\G LEGE\D PIPE IDENTIFICATION PIPE IDENTIFICATION PIPE FITTINGS PIPING SPECIALTIES WELDING GENERAL SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION —PW— PROCESS WATER i— SOLVENT CEMENT * TEST PLUG —i >-- BREAK IN PIPE —A— COMPRESSED AIR. PLANT L L ROOT OPENING CONTOUR SYMBOL GROOVE ANGLE, —RD— ROOF DRAIN SPRING HANGER 1 THERMOMETER, LINE MOUNT DEPTH OF FILLING FINISH SYMBOL OF COUNTERINCLUDED SINK CROSSING LINES, NO CONNECTION —AR— ARGON GAS , FOR PLUG AND FOR PLUGWELD \J\ DIRECTION OF FLOW —AW— ACID WASTE —RDS— REFRIGERANT DISCHARGE --II-- UNION, FLANGED �_ THERMOMETER, SEPARABLE WELL MOUNT SLOT WELDS LENGTH OF WELD IVE SLOPE DOWN —C— CONDENSATE RETURN (GRAVITY) —RHO— REFRIGERANT HOT GAS �� UNION, SCREWED D TRAP, FLOAT THROAT F PITCHNT(CENTER TO DIRECTION OF SLOPE, SIZE OR CENTER SPACING) OF WELDS MEQUIPMENT MARK NUMBER —CD— CHEMICAL DRAIN —RL— REFRIGERANT LIQUID .----• WELDED FITTING Q TRAP SEAL PRIMER VALVE FOR A CERTAIN WELDS FIELD WELD SYMBOL R /-EXIST EXISTING WORK —CF— CHEMICAL FEED —RS— REFRIGERANT SUCTION (GAS)\ -}�+- HOSE KIT v-1 UNCLASSIFIED VALVE \ i� g ARROW CONNECTING REFERENCE mss- EXISTING TO BE REMOVED —CHWR— CHILLED WATER RETURN —RWL— RAIN WATER LEADER Q VACUUM DROP (LAB VAC) .1>s (E){g €v}L–P UNE TO ARROW SIDE ARROW IDE HIDDEN OR BELOW GRADE —CHWS— CHILLED WATER SUPPLY —S— SPRINKLER LINE Qv VACUUM OUTLET (LAB VAC) HARD PIPED {I ig} OEMRER OFJOINT —o� IN-UNE RECIRCULATING PUMP —CLD— CLEAR WATER DRAIN —SAN— SANITARY WASTE ABOVE GRADE OR FLOOR PIPING SPECIALTIES Q VACUUM CLEANING OUTLET (N) WELD ALL AROUND INSULATED PIPE —CLWR— COOLING WATER RETURN --SAN-- SANITARY WASTE BELOW GRADE OR FLOOR SYMBOL DESCRIPTION Q VALVE BOX SYMBOL -6=?,- INSULATED PIPE WITH ELECTRIC HEAT TRACING • —CLWS— COOLING WATER SUPPLY —PCD— PUMPED CONDENSATE DRAIN --1% 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR -1‹:04-- VALVE IN RISER (TYPE SPECIFIED) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN REFERENCE UNE TAIL AND ARROW ARE —CRV— CORROSION RESISTANT VENT —STM— STEAM SUPPLY. —PTO— 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR I WATER HAMMER ARRESTOR REVERSED NUMBER OF SPOT OR PROJECTION WELDS NEW WORK •POC POINT OF CONNECTION —CRW— CORROSION RESISTANT WASTE — SW — SITE WATER A / A AIR DROP - HOSE, SIMPLEX / DUPLEX WYE STRAINER (WITH DRAIN VALVE) \ ° PUMP —CTFR— COOLING TOWER FILTER RETURN —TP— TRAP PRIMER 9 / 6 AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX BASO WELD SYMBOL OR REFERENCE TDETAIL AIL MAY E N E ONOT —CIES— COOLING TOWER FILTER SUPPLY —V— VENT 1 Ln ANGLE GLOBE VALVE, ELEVATION / PLAN USEDWHEN R CEBT USE FIXTURES -CDWR- CONDENSER WATER RETURN —VAC— VACUUM 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) SPECIFICATIONS, PROCESS OR OTHER REFERENCE —CDWS— CONDENSER WATER SUPPLY —VPD— VACUUM PUMP DISCHARGE 72Av AUTOMATIC AIR VENT (WITH DRAIN) SYMBOL DESCRIPTION —CW— DOMESTIC COLD WATER BFP BACKFLOW PREVENTER p BACK WELD O CIRCULAR WASHFOUNTAIN FOUNTAIN —D— DRAIN PIPE FITTINGS --W- BALANCE VALVE WITH METERING PORTS , FILLET WELD ElDE DRINKING • COOLER — DI— DEIONIZED WATER SYMBOL DESCRIPTION—PO— BALANCE VALVE W/O METERING PORTS I—I PLUG OR SLOT WELD a EN'C ELECTRIC WATER BELL & SPIGOT i¢H/-IiH BALL VALVE, OPEN / CLOSED II SQUARE WELD ra EWCH ELECTRIC WATER COOLER FOR HANDICAPPED —OW— DISTILLED WATER -3--3- BUND FLANGE —Lei— BUTTERFLY VALVE O SPOT OR PROJECTION WELD 0 FLOOR DRAIN —F— FIRE LINE, AHEAD OF ALARM VALVE FD ROUND COUNTER MOUNT —FH— FIRE HOSE CABINET PIPING ---0-- BUSHING —itil-- COOLING COIL CHILLED WATER Q LAv LAVATORY, OR WALL MOUNT —FOR— FUEL OIL RETURN —1.1P— EXPANSION JOINT FLOAT VALVE ® uv LAVATORY, RECTANGULAR COUNTER CLOSET, FLUSH VALVE, WALL HUNG —FOS— FUEL OIL SUPPLY -0-0- FLANGED FITTING --1:4— FLOWMETER, VENTURI TYPE rpWC WATER —FOV— FUEL OIL VENT -MO- FLEXIBLE PIPE CONNECTION —f I I— FLOWMETER ORIFICE —FW— FILTERED WATERHs HOSE BIBB -0o-/-II.4- ISOLATION VALVE, OPEN / CLOSE —G— NATURALNFHB �- HOSE BIBB - NON FREEZE _A— GATE VALVE, OUTSIDE SCREW AND YOKE PIPE ANCHOR —04 GATE VALVE, WITH HOSE CONNECTION —HPC— CONDENSATE, STEAM (HIGH PRESSURE) —X— PIPE CAP SCREWED OR SOLDER JOINT 403-/4.1" GLOBE VALVE, OPEN / CLOSED —HPR— CONDENSATE RETURN (HIGH PRESSURE) T OR GROOVED —FEal- HEATING COIL REVIEWED FOR —HPS— STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) PIPE CAP, WELDED —HPWS— HEAT PUMP WATER SUPPLY —.i.— PIPE CROSS -VF/ LIFT CHECK VALVE CODE COMPLIANCE —HPWR— HEAT PUMP WATER RETURN —'}SR PIPE ELBOW, 90' SHORT RADIUS v MANUAL AIR VENT (WITH DRAIN) APPROVED —'} PIPE ELBOW, 90' LONG RADIUS MOTOR OPERATED VALVE —HRS— HEAT RECOVERY SUPPLY —HRR— HEAT RECOVERY RETURN —'q PIPE ELBOW, REDUCING- NEEDLE VALVE JUL 9 4 2013 —MW— DOMESTIC HOT WATER SUPPLY ---.\ PIPE ELBOW, 45' © NITROGEN DROP —HWC— DOMESTIC HOT WATER CIRCULATING —b PIPE ELBOW, TURNED UP OR TOWARD Q NITROGEN OUTLET I.— PETCOCK —HWR— HEATING WATER RETURN PIPE ELBOW, TURNED DOWN OR AWAY - CityTukwila PIPE GUIDE t-4`I{ PETE'S PLUG, WITH BALL VALVE - of WASTE FITTINGS —HWS— HEATING WATER SUPPLY = DIVISION HANGER PLUG VALVE/STOP COCK BUILDING SYMBOL DESCRIPTION — IA — INSTRUMENT AIR /4— PIPE —44— 1/4 BEND —ID— INDIRECT DRAIN x 1 r PIPING MATERIAL CHANGE, X TO Y IQ PRESSURE GAUGE WITH VALVE PIPE PLUG PRESSURE REGULATING VALVE W/EXT PRESS TAP —I i CO CLEAN OUT, EXPOSED —IW— INDUSTRIAL WASTE —.o c LIQUID NITROGEN t— PIPE REDUCER CONCENTRIC PRESSURE REGULATING VALVE (SELF CONTAINED) CLEAN OUT, FLOOR —LAIR— —LPC— CONDENSATE, STEAM (LOW PRESSURE) o— PIPE REDUCER ECCENTRIC PRESSURE RELIEF VALVE / SAFETY VALVE RECEIVED —I RICO CLEAN OUT, WALL x FUNNEL FLOOR DRAIN —LPG— LIQUID PETROLEUM GAS PIPE SUPPORT —� QUICK OPENING VALVE CITY OF TUKWILA FFO ❑1 FUNNEL DRAIN —LPS— STEAM SUPPLY (LOW PRESS, 0-15 PSIG) —*}'— PIPE TEE, STRAIGHT —64— QUICK CLOSING VALVE, FUSIBLE UNK FUD CONDENSATE, STEAM (MEDIUM PRESSURE) —.O.— PIPE TEE, UP OR TOWARD —A SOLENOID OPERATED VALVE I) LATERAL —MPC— JUL 1 5 2013 OR AWAY ---En— STEAM TRAP TRENCH DRAIN —MPS— STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) —•0' PIPE TEE, DOWN SCREWED FITTING OR AS SPECIFIED — - SWING CHECK VALVE WITH FLOW () WASTE RECEPTOR, ROOF —OFD— OVERFLOW DRAIN I I wR GAS PRESSURE REGULATOR PERMIT CENTER --F-yiIco WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT —PCWS— PROCESS COOLING WATER SOURCE f SEISMIC HANGER -:70- Ji;;;) FLOOR DRAIN —PCWR— PROCESS COOLING WATER RETURN -X--,"^ SEISMIC LOOP 0 FD FD FLOOR DRAIN ABOVE —PR— CONDENSATE RETURN (PUMPED) 00 SOLDERED FITTING FOR CONSTRUCTION LOJ cuaw'r R9 meoE as BY APPROVED 540E SYM REVISION NY APPROVED 5405 - ACCEPTABILITY "I suemtFDATE PIPING LEGEND 12061 B 07.24.12 SW REVISION , 81 •v";4 ESIGN AND/OR APPROVED CHECKED SHEET - DEVELOPMENT LAB - 50S IFR W11_12058 WH GV 06.22.12 O/'� SPETHIS /FHCINELN TIRE INTEGRATED TECHNICAL DEVELOPMENT LAB GV 87.12.12 U" ''S APPRODED BY DEPT. DATE I M 1 A A DEVELOPMENT LAB - 90% IFR WH_I2058 WH ?Ile,/EAA/NC® CHECKED B DEVELOPMENT LAB - IFC WH_12058 WH GV 07.24.12 1598.2 �' APPROVED BUILDING 9-53.1 ADB N0. 9_12061 COMP N0. DAD AU, T v� """H0° ° MECHANICAL MASTER DEV. CENTER, WA 9-53.1-M1A • VECHA\ICAL GE\EAL \OTES 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. 2. DRAWINGS INDICATE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE WORK OF OTHER TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH -IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY THE IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE AND HUMIDITY SENSORS, PANELS, SWITHCHES), SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL SYSTEM(E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS, AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. COORDINATE THE SIZE AND LOCATION OF EQUIPMENT HOUSEKEEPING PADS WITH APPROVED EQUIPMENT SO THAT HOUSEKEEPING PADS ARE NOMINALLY 4" HIGH UNLESS INDICATED OTHERWISE, AND EXTEND 6" MINIMUM IN ALL DIRECTIONS FROM THE HORIZONTAL LIMITS OF THE EQUIPMENT WHICH THEY SUPPORT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILING MOUNTED ITEMS. INSTALL CEILING MOUNTED ITEMS IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE LOCATION OF ITEMS ARE NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO ROUGH -IN AND INSTALLATION. 7. COORDINATE EQUIPMENT POWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULED VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER, ETC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE COST FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 8. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 9. DO NOT RESTRICT ACCESS TO ELECTRICAL CABLE TRAYS. AT A MINIMUM, ALLOW 18" CLEAR ON ONE SIDE OF CABLE TRAYS UP TO AN ELEVATION OF 6" ABOVE THE TOP OF THE CABLE TRAY. MAINTAIN 12" MINIMUM CLEARANCE OVER TOP OF CABLE TRAYS EXCEPT WHERE DUCT, PIPING, OR CONDUIT CROSS PERPENDICULAR TO CABLE TRAY, THIS CLEARANCE MAY BE REDUCED TO 6" OVER A DISTANCE OF NO MORE THAN 36" ALONG THE CABLE TRAY. PROVIDE NO LESS THAN 36" BETWEEN AREAS OF REDUCED CLEARANCE AND MAINTAIN INDICATED ACCESS ON THE SAME SIDE OF THE CABLE TRAY EXCEPT WHERE OTHERWISE APPROVED. DO NOT CONNECT TO CABLE TRAYS, CABLE TRAY SUPPORTS OR CABLE TRAY SEISMIC RESTRAINTS. 10. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES, DUCTS, AND EQUIPMENT AS SPECIFIED, AS REQUIRED, AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENT TO THE STRUCTURAL MEMBERS SHALL BE MADE ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BETWEEN STRUCTURAL MEMBERS ON ANY ELEMENTS DESIGNATED IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. 11. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS OR SHEAR WALLS UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. 12. PROVIDE PIPE SLEEVES AND PENETRATION SEALS AS REQUIRED FOR THE INSTALLATION OF PIPING SYSTEMS. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 13. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 14. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTINGS, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTINGS, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE COST OF RE -WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 15. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALLAS POSSIBLE. PROVIDE ADDITIONAL FITTINGS AND OFFSETS AS REQUIRED. 16. REFER TO EQUIPMENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES TO INDICATE THE CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 17. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDIVIDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 18. DUCTWORK SERVING INDIVIDUAL DIFFUSERS AND GRILLES IS GENERALLY NOT SIZED. WHERE NOT INDICATED ON PLAN DRAWINGS, REFER TO SCHEDULES AND DETAILS FOR NECK AND BRANCH DUCT SIZES BASED ON INDICATED AIRFLOW RATE OR NECK SIZE. 19. PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY GRILLE, IN ALL BRANCH DUCTS WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. LOCATE VOLUME DAMPERS AS FAR AS POSSIBLE FROM OPENINGS. FOR THE PURPOSE OF THIS REQUIREMENT, TERMINAL UNIT PRIMARY AIR DAMPERS ARE CONSIDERED A VOLUME DAMPER. VOLUME DAMPERS ARE NOT REQUIRED FOR CEILING RETURN GRILLES THAT TRANSFER AIR TO A RETURN AIR PLENUM UNLESS OTHERWISE INDICATED. 20. PROVIDE CONICAL TAPS FOR 90 DEGREE- ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE FITTINGS. 21. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA HDCS: DUCT SYSTEM STATIC PRESSURE A. DOWNSTREAM OF TERMINAL UNITS +1 INCHES WG B. UPSTREAM OF TERMINAL UNITS +10 INCHES WG C. DOWNSTREAM OF COMPUTER ROOM UNITS +1 INCHES WG SYN REVISION BY APPRWm 001E SYU REVISION 00 DATE DEVELOPMENT LAB - 50% IFR W11_12058 WH GV 06.22.12 A DEVELOPMENT LAB - 90% IFR WH_12058 W11 OV 07.12.12 B DEVELOPMENT LAB - IFC W11_12058 WH OV 07.24.12 ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION 15 APPROVED NLINEEN DRAWN DATE SEALC CLASS A C REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION APPROVED BY DEPT. DATE SUBTR E MECHANICAL GENERAL NOTES CURRENT REVISION 9-12061 SYMBOL DATE 07.24.12 CHECKED APPROVED INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SNEET M2 100 NO 9-12061 COUP NO. DWG N0. 9-53.1-M2 SYM ip 100 CFM (8"NECK) 1M13 1M451 200 CFM FOR ENLARGED PLAN OF THE AREA BELOW LAY -IN CEILING, SEE 1M13MM450 43506M L a j6 1M13 V,EW6 12 riOr .43 FOR TERMI INSTALLATID SEE UNIT DETAIL, 4 26/12 28/24 26/16 UP 36/24 UP 26/4 270 CFM Yl 26 14 n 28/24 1M13 M50 FOR DIFFUSER INSTALLATION D SEE 1M13 1 /14 UP 100 CFM 16/20 Ino 0/24 FD 10/10 150 CFM (TYP 10X10 600 CFM H 400 CFM CC SBB REVIEWED FOR CODE COMPLIANCE APPROVED 180 CFM (TYP 5) 700 CFM (TYP 725 CFM [HI CD 150 2 CFM RG \ 700 CFM 100 CFM (TYP 10X8 i BY APPROVED DTE SYM REVISION 150 CFM (TYP FIRST FLOOR PLAN - NORTH BY APPRO/ED K DEVELOPMENT IAB - IFC 1111_12058 WH CV 04.01.13 F ADD DETAIL 1/16451 9686868 HARR L DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH CEL 06.20.13 G MODIFY BRIJ COMPUTING LAB 10697207 M.WONG RWS C RECORD DRAWING MJC KMR/RB 8.30.91 H INSTL DROPPED CEILINGS RMS 12883 At 11084 10428-10 HARR D REFEED 4 EXIST. DIFF. 0 CC -5.5 170051 RAD RWS I DEVELOPMENT LAB - 50% IFR WH_12058 WH DV E RELOC NCO LAB 12011000 RWS RWS 08.27.03 J DEVELOPMENT LAB - 90% IFR WH_12058 WH CV DTE 01/27/10 06.17.10 09/07/11 06.22.12 07.12.12 BOE®A/G® DRAWN ACCEPTABILITY L DEWALT , D. MEYER THIS DESIGN AND/OR SPECIFICATION IS APPROJED 'LNGwE E APPROVED BY DEPT. DATE D. MEYER NECKED K. RAMSEY APPRoVE6 K. K. RAMSEY JUL 9 4 2013 AA. 5 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND GENERAL NOTES 1. SOUND -LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. E> SECURE PENETRATION, SEE DETAIL [Ti SECURE PENETRATION SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. SECURE PENETRATION SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. TYP M501 TYP I M501 TYP M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. 8 > FOR TERMINAL UNIT DIAGRAM, SEE 1M13 M311 REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE LOW LEAKAGE CONTROL DAMPER. THE DAMPER SHALL BE CONTROLLED BY THE DDC SYSTEM. CAP EXISTING COLD AND HOT AIR DUCTS. RE -CALIBRATE EXISTING TERMINAL UNIT AND ADJUS AIRFLOW SETPOINT TO 200 CFM. ® RE -BALANCE EXISTING DIFFUSER AND GRILLES TO INDICATED AIRFLOW. m DO 0 0 0 0 0 0 0 0e 0 • 111111/111111 IIlI115/111.1U� M11MI■■r111111Irm =muEZIEMINI iiiiiiiiiiiIIKI LIiI•U•■■■■■ai ■ILA____■__■_ 0 FOR CONSTRUCTION ;DATE SUBTITLE FIRST FLOOR HVAC PLAN - NORTH KEY PLAN MOTTO SONE 8 4 0 2 4 16 — --E _- SCALE. 1/8" = 1'-0" CURRENT PENSION SYMBOL 9-12061 L DATE 06.20.13 LLAW TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 5.1790 MECHANICAL MASTER SHEET 1M13 £0 NO. COUP NO. COL. A-CC/1-6 DEV. CENTER, WA Dwc 9-53.1-1M13 26/14 UP 36/24 UP 220 CFM (TYP 1q 14/12 26 14 0 9014 0118/14 v 36/24 L7� 4 24 1 124/20 On 24/14 n < 'ell 124/24 ! ii 24/22 1 14/10 14/8 14/12 230 CF (TYP 3) 10x8 150 CFM 40/24 7 FOR ENLARGED PLAN OF THE AREA BELOW LAY -IN CEILING, SEE ) SEE ANSFER DUCT DETAIL 14 M501 12/16 18/14 UP 22/18 UP 11251 200 CFM 290 CFM TYP 600 CFM (6 TYP) 230 CFM TYP 9 OF 12/16 850 CFM (2 TYP) 10/10 CD 305 CFM OFFICE 195 CFM (TYP MATCHLINE - SE OFFICE 180 CFM (3 TYP) {gg r.5 (AA A) I ag ti I 240 CFM TYP FIRST FLOOR PLAN - SOUTH LEGEND GENERAL NOTES 1. SOUND -LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. 7> SECURE PENETRATION. SEE DETAIL I 4 > SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. W> SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE Si OF .•LL TYP M501 TY? M501 TYP I M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS REVIEWED FOR CODE COMPLIANCEp APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION NSTRUCTION NOTES RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION lel O O O O000�9 Cj �LOLrr611.uu11,■ Y/ %io '/.U..., ilt, ■Nionimmmor•mmsgym •11•a•••■iIil� O .I._____.___ MIIIIIIMIEEMIDEME111= O MINItIMINIIIIIl•IIMMI! o Imidummmmmmumilmismilmcs MILIOLM:11111111111M KEY PLAN TOT 10 SUE 8 4 0 2 4 16 — — - SCALE 1/8. = 1'-0' STM A RECORD DRAWING MOVE THERMOSTAT RELOCATE NCO LAB DEVELOPMENT LAB - 50% IFR WH_12050 DEVELOPMENT LAB - 90% IFR WH_12058 BY MJC APFRENED DATE SYIA REVISION BY APPROVED DATE 81321849 12011000 SLB RWS WH WH KMR/RB RWS RWS CV 6V 8.30.91 DEVELOPMENT LAB - IFC WH_12058 WH CV 07.24.12 08.28.03 06.22.12 07.12.12 �BOE�A/G® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED •' WN L DEWALT CHECKED D. MEYER DATE SUBTITLE FIRST FLOOR HVAC PLAN - SOUTH CURRENT REVISION 9-12061 SYMBOL F DATE 07.24.12 APPROVED BY DEPT. DATE ENLINEEN W. HENCKEL CHECKED K. RAMSEY APPROVED K. RAMSEY APPNUVLD L LAW 5.17.90 _ TIRE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/6-11 DEV. CENTER, WA SHEET 1M14 JOB NO. DWG NO. D1321848 COMP ND. 9-53-1M14 lel O O O O000�9 Cj �LOLrr611.uu11,■ Y/ %io '/.U..., ilt, ■Nionimmmor•mmsgym •11•a•••■iIil� O .I._____.___ MIIIIIIMIEEMIDEME111= O MINItIMINIIIIIl•IIMMI! o Imidummmmmmumilmismilmcs MILIOLM:11111111111M KEY PLAN TOT 10 SUE 8 4 0 2 4 16 — — - SCALE 1/8. = 1'-0' STM A RECORD DRAWING MOVE THERMOSTAT RELOCATE NCO LAB DEVELOPMENT LAB - 50% IFR WH_12050 DEVELOPMENT LAB - 90% IFR WH_12058 BY MJC APFRENED DATE SYIA REVISION BY APPROVED DATE 81321849 12011000 SLB RWS WH WH KMR/RB RWS RWS CV 6V 8.30.91 DEVELOPMENT LAB - IFC WH_12058 WH CV 07.24.12 08.28.03 06.22.12 07.12.12 �BOE�A/G® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED •' WN L DEWALT CHECKED D. MEYER DATE SUBTITLE FIRST FLOOR HVAC PLAN - SOUTH CURRENT REVISION 9-12061 SYMBOL F DATE 07.24.12 APPROVED BY DEPT. DATE ENLINEEN W. HENCKEL CHECKED K. RAMSEY APPROVED K. RAMSEY APPNUVLD L LAW 5.17.90 _ TIRE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/6-11 DEV. CENTER, WA SHEET 1M14 JOB NO. DWG NO. D1321848 COMP ND. 9-53-1M14 10 3 IES 11211 6" :2 2BB6 6"CHWS UP INN Ls I 11341 11251 UT2C LAB r== 3' DN TO CR1BB6, SEE M64 1M506 EARTHQUAKE BRACING (TYP) )< 4" CHWS 2 1/2• CHWR 11261 CONFERENCE Lit' =1 D H OFFICE OFFICE UT1H MIC ROOM UTI OFF I' S J LAB UT9 CONFERENCE ROOM L> 8•CHWS EXISTING FIRST FLOOR PLAN - SOUTH 1/8•=1'-0• 111II II1 II II JI 1L STM A RELOCATE NCO LAB BY APPROVED DATE STM BENSON BY APPROVED DATE 120110-00 RW5 RW5 09.02.03 8 DESIGN ACOUIRE/INSTALL 30T0N UEBERT 11181858 M.WONG RV5 10.26.10 C DEVELOPMENT LAB - ECN-01 - WH 12058 9-12061 WH CEL 06.20.13 II it U I11 I II JI IL-__ GENERAL NOTES I 1 > CONNECT TO EXISTING 8"CHWS AT FLANGE 2 > PROVIDE ISOLATION VALVE AND CM' FOR FUTURE CONNECTION. FOR SHIELDING SEE SHEET A517. ' 1 4 > CR1BB6, 30 TON CHILLED WATER COMPUTER ROOM AIR CONDITIONER, DOWNFLOW, 2 -WAY MODULATING CONTROL VALVE, VARIABLE DRIVE, ICOM CONTROL, 15HP MOTOR, 0.5" SP, ELECTRIC REHEAT, INFRARED HUMIDIFIER. (BE.5 (BP DRAWN ACCEPTABILITY L DEWALT THIS DES0 NTD/OR MEYER SPSPECIFICATIOND. N IS APPROVED 'D. AEYE APPROVED BY DEPT. DATE W. HENCKEL DAT! (AA.5 REVIEWED FOR CODE COMPLIANCE KMAPPROVED CA-JUL 9 4 2013 City of Tukwila BUILDING DIVISION 1..> SEE SHEET M450 FOR CR2886 REFRIGERANT PIPING. CONSTRUCTION NOTES REMOVE EXISTING 30 -TON UPFLOW CRU, PACKAGE FOR SHIPMENT, AND DELIVER TO BOEING. CONTACT BOEING CONSTRUCTION MANAGER FOR LOCATION. INSTALL REPLACEMENT DOWN -FLOW CRU FURNISHED BY BOEING. REMOVE AND RE -CONNECT EXISTING CHILLED WATER SUPPLY AND RETURN PIPING TO NEW CR1BB6. SEE 1 M506 FOR PIPING DETAIL. INSULATE THE CHILLED WATER PIPING WITH 1• THICK FIBERGLASS PIPE INSULATION RECEIVED CITY OF TUKWILA JUL 1 5 20'i3 PERMIT CENTER 6 -OI) 0 o000000 0 • M/`� E// 111111 ■ ■i1■■■■■■■`m MIIIIIIIIBENIZIMESECEM ..I-.....■-- MIMMII•IIII..■.1E1 MIIIIIMMINIMMINNINI I !j•■■■■■■■r ■AL1----■■■■� KEY PLAN NOT TO WALE FOR CONSTRUCTION SUBTITLE FIRST FLOOR HVAC PIPING PLAN - SOUTH CURRENT REVISION SYMBOL 9-12061 V DATE 06.20.13 TRS INTEGRATED TECHNICAL DEVELOPMENT LAB W. HENCKEL .D K.RAMSEY L LA _ MECHANICAL MASTER BUILDING 9-53.1 SHEET .08 NO. 1M64 120110-00 COMP NO. COL. A -C /6-11 DEV. CENTER, WA TWA NO. 9-53-1M64 0 0 1/2"CW DN THROUGH RAISED FLOOR TILE, SEAL PIPE PENETRATION° AIR TIGHT 1/2"CW TO CR2B86 CR2886, FOR PIPING DIAGRAM, SEE 1M113 M504 1M11 i, T 3/4"CD FROM CR3BB6, FOR CONTINUATION SEE 1M114_\ 1/2"Cw TO CR3BB6, FOR CONTINUATION SEE 1M114 3/4"CD FROM COMPUTER ROOM AIR CONDITIONING UNITS 2"SAN UP TO FD -2 {CC LEGEND GENERAL NOTES 1> PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION; 1" AIR, 3/4"CW. 12i 1" AIR DROP. SEE DETAIL I3> TYPIM501 FOR SHIELDING SEE SHEET A517. 4 > TERMINATE ROOF OVERFLOW DRAIN ABOUT 2 FT. ABOVE FINISHED GRADE WITH WELDED MITERED ELBOW. I5> 6"STS DOWN - SEE DETAIL 1M113 I—T--IO2 6"OFD UP 2"ID UP 1 /2CW" 1/2"CW FROM CR1B86, FOR CONTINUATION SEE 1M114 (E)3/4" POC 1-1/2"CD 1"AIR UP 6" DIRT LE' AT BOTTOM 3"CW UP ®FD -2A a 2"V 2"SAN UP TO FD -2 6"STS UP 3"V UP 3" VENT UNDER RAISED FLOOR (BB.5 3"V DOWN, FOR CONTINUATION SEE SHEET UGM111 SEE SHEET 1M114 r Lo V n ®FD -2 2"V UP 2" UP TO FD -2 2"V UP 2"SAN DN 3""- ID HA H TO FD -2 II 2" SAN C.O. 2"SAN UP �TO P-6 EXPANSION JOINT H (BB (AA.5 (AA A) FOR CONTINUATION SEE SHEET M103 U EARTHQU BRACING FIRST FLOOR PLAN - NORTH SYM RMSION A REVISED ID MID SAN SYSTEMS 8 R1 LAB REVISION C REVISED FLOOR DRAIN VENTS D MOVED PIPES FROM STAIRWAY E RECORD DRAWING BT MJC /DM DATE SYM BY APPROVED DATE MJC MJC MJC MJC KMR ILL KMR /LL KMR ILL KMR ILL KMR /RB 6.25.90 9.7.90 9.20.90 10.25.90 8.30.91 DEVELOPMENT LAB - 50% IFR WH_12058 DEVELOPMENT LAB - 90% FR WH_12058 DEVELOPMENT LAB - IFC WH_12058 WH WH WH CV GV GV 06.22.12 07.12.12 07.24.12 gLITAFEIA eG* ACCEPTABILITY THIS DESIGN AND/DR SPECIFICATION IS APPROVED -MOM CHECKED D.MEYER REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION M DATE SUBTITLE PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION. 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES TERMINATE 1-1/2"CD 2" ABOVE BOTTOM OF THE FLOOR SINK. KEY PLAN NOT TO SUE FIRST FLOOR PLUMBING - NORTH 8 4 0 2 4 16 -_— SCALE: 1/8" = 1.-0" CURRENT REVISION 9-12061 SYMBOL H DTE 07.24.12 APPROVED BY DEPT.. DATE LNLINLLN W.HENCREL CHECKED K.RAMSEY APPROVED K.RAMSEY MPUR ED L 5.1790 _ TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. A-CC/1-6 DEV. CENTER, WA SHEET 1M113 JOB NO. COMP NO. DWG NO. 9-53.1-1M113 OFFICE OFFICE 103 (0) (9) EXIT VESTIBULE 2"SAN DN WCO UNDER L I i I FOR PLUMBING THIS AREA SEE SHEET 1M454 2"ID UP TO FD -2 CIC O CI 3"ID N 3" 1 ID FD -2 3/4_w7 Ibl r 2" L OFFif ID UP -2 -2 C.O. 2"ID UP TO FD -2 H0 1-10 2"SAN UP UTiH MIC RuO� TO P-6 2% C.O. EE UT1 OFFI ES F, VT OFFICE 7 3" 210 UP TO FD -2 UT9 CONFERENCE ROOM O. OFFICE SAN C.Q. ID A Nf J TTI -- } I - 2% CR3BB6 FOR PIPING DIAGRAM, SEE 1M114 1504 3/4"CD FROM CR3BB6. FOR CONTINUATION, SEE 1M 113 1/2"CW TO CR3BB6, FOR CONTINUATION, SEE 1M113 SEE DETAIL 3 1M11411M506 UT2C LAB ID 3/4" Cw FD -2 3" 2"ID UP TO FD -2 r== M )4 -CW POC 1/2"CW DN ID ONE RENCE CW 2% C.O. ID 3/4" • I�1 A IL FD 2% FIRST FLOOR PLAN - SOUTH 1/8"=1'-O" L LAB 2"ID UP TO FD -2 JIki C.O. ID I I C.O. IA 3/4"COND DRAIN 1/2"CW 3/4"COND DRAIN N LAT a J LAB SAN 2" 1 II II - II II II II JI IL-_ SYM REVISION BY APPROVED DATE SYM AT APPROVED DATE A REVISED ID AND SAN SYSTEMS MJC/DM KMR/LL 6.25.90 F DEVELOPMENT LAB - 90% FR WH_12058 WH CV 07.12.12 B RECORD DRAWING AUC KMR/RB 8.30.91 G DEVELOPMENT LAB - IFC WH_12058 WH OV 04.01.13 C RELOCATE NCO LAB 120110-00 RWS RWS 09.02.03 H DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WN CEL 06.20.13 D DESIGN ACQUIRE/INSTALL 30TON UEBERT 11181858 M.WONG RWS 10.26.10 E DEVELOPMENT LAB - 50% IFR W11_12058 9-12061 WH GV 06.22.12 gifinswzAvc. DRAWN ACCEPTABILITY L DEWALT THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED D. MEYER l.INELH APPROVED BY DEPT. DATE WN, HENCKEL CHECKED W. HENCKEL AA. RAMSEY APPROVED L LAW (BU REVIEWED FOR CODE COMPLIANCE APPROVED (- 94 2013 • City of Tukwila BUILDING DIVISION DATE A) — RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND GENERAL NOTES (—� PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION; 1" AIR, 3 4"CW 2. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 3.GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES DISCONNECT 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN FROM EXISTING CR1BB6. REMOVE EXISTING PIPING AND ACCESSORIES AND PROVIDE NEW 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN PIPING AND ACCESSORIES AS REQUIRED FOR CONNECTION TO NEW COMPUTER ROOM UNIT CR1BB6. PROVIDE NEW 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN PIPING AND ACCESSORIES FOR CR3BB6 FOR CONSTRUCTION SUBTITLE FIRST FLOOR PLUMBING PLAN - SOUTH IN 91 lBl (71 I • KEY PLAN NOT TO SCUD 8 4 0 2 4 Al Bl CI 16 SCALE: 1/8" = 1'-0" CURRENT REVISION SYMBOL 9-12061 H DATE 06.20.13 TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 SHEET �BNO. 1M114 OWE NO. 5.17.90 MECHANICAL MASTER COL. A-CC/6-71 DEV. CENTER, WA 89065 9-53.1-1M114 COMP N0. TO DDC COLD AISLE CONTAINMENT CURTAIN, SEE ARCHITECTURAL DRAWINGS RACK INLET AIR TEMPERATURE SENSOR, SEE PLANS FOR QUANTITY AND LOCATION, TYP SEQUENCE OF OPERATION DDC CONTROL PANEL SITELINK NETWORK SWITCH CONTROL WIRING FROM SERVER RACK TEMPERATURE SENSORS, TYPICAL ICOM CONTROL PANEL W INTELLISLOT COMMUNICATION CARD L ROOM TEMPERATURE AND HUMIDITY IS CONTROLLED BY COMPUTER ROOM UNITS WITH STAND ALONE CONTROLS, THAT MAINTAIN PROPER OPERATION OF THE ASSOCIATED EQUIPMENT AND SENDS A SUMMARY ALARM AND A UNIT FAILURE STATUS TO THE DDC DEFINED BY THE USER. THE DDC SYSTEM WILL MONITOR TEMPERATURE, RELATIVE HUMIDITY, AND A CRU CRITICAL ALARM (UNIT FAILURE) AND A COMMON SUMMARY ALARM POINT. WHERE A COMMON POINT IS NOT AVAILABLE THE DDC SHALL COMBINE THE USER DEFINED POINTS INTO A COMMON POINT CRU CONTROL (CR2BB6 & CR3BB6) THE CRU LOCAL CONTROL PANEL SHALL BE SET TO OPERATE CRU FAN SPEED TO MAINTAIN THE WORST CASE AISLE INLET TEMPERATURE BETWEEN 68 AND 72 DEG F. THE CRU LOCAL CONTROL SHALL CYCLE THE HUMIDIFIER AND THE ELECTRIC REHEAT COIL TO MAINTAIN RETURN AIR HUMIDITY BETWEEN 25 TO 50% RH (CORRESPONDING TO 35 AND 65% RH AT THE RACK INLET). IF ONE UNIT HAS FAILED THEN THE HUMIDITY CONTROL FUNCTIONS SHALL BE DISABLED. THE CRU LOCAL CONTROL PANEL SHALL CYCLE THE COMPRESSOR AND THE ECONOMIZER CYCLE TO PROVIDE THE SUPPLY AIR SETPONT AS DETERMINED WITHIN THE CRU CONTROL PANEL THE CRU LOCAL CONTROL PANEL SHALL CYCLE THE COMPRESSOR, THE ECONOMIZER CYCLE AND THE LEE TEMPERATURE CONTROL CIRCUIT AS REQUIRED FOR ENERGY CODE COMPLIANCE AND PROPER EQUIPMENT PROTECTION BY MEASURING THE AMBIENT TEMPERATURE AT THE CONDENSER. r J r ✓ r RA r -- J% TEVTE\/LS FILTER EVAPORATOR COILS FFF 1111 aaaEA TTTT CRU CONTROL (C R11366); THE CRU LOCAL CONTROL PANEL SHALL BE SET TO OPERATE CRU FAN SPEED AND THE CHILLED WATER CONTROL VALVE TO MAINTAIN THE RETURN AIR TEMPERATURE BETWEEN 80 AND 84 DEG F. THE CRU LOCAL CONTROL SHALL CYCLE THE HUMIDIFIER AND THE ELECTRIC REHEAT COIL TO MAINTAIN RETURN AIR HUMIDITY BETWEEN 25 TO 50% RH (CORRESPONDING TO 35 AND 65% RH AT THE RACK INLET). IF ONE UNIT HAS FAILED THEN THE HUMIDITY CONTROL FUNCTIONS SHALL BE DISABLED. TEAMWORK MODE ALL UNITS SHALL OPERATE IN TEAMWORK MODE SO DEHUMIDIFICATION AND HUMIDIFICATION DOES NOT OCCUR SIMULTANEOUSLY. ALL UNITS SHALL OPERATE IN TEAMWORK MODE SO COOLING AND HEATING DOES NOT OCCUR SIMULTANEOUSLY COMPUTER ROOM UNIT CONTROL DIAGRAM n SCALE: NTS SUPPLY/ AIR \ TO DDC -- r— UNIT CONTROL MODULE r_I PAD M4891911 TERMINAL UNIT SHALL OPERATE CONTINUOUSLY. SEQUENCE OF OPERATIO Jj TERMINAL UNIT PROVIDES VENTILATION AIR AND PO ITIVE PRESSURIZATION OF THE LAB AT ALL TIMES, PRIMARY AIR IS SUPPLIED FROM CENTRAL SYSTEM, WHICH OPERATES CONTINUOUSLY. INTERFACE CONTROL DAMPER TO FIRE ALARM SYSTEM TO CLOSE DAMPER WHENEVER THE FIRE SUPPRESSION SYSTEM FOR THE INTEGRATED DEVELOPMENT LAB IS ACTIVATED. TERMINAL UNIT P&ID SCALE: NTS 1M13 M311 LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. ATE ON HE M S : L : PLY REFRIGERANT PIPING, FOR PIPING DIAGRAM, SEE O M311 M504 REFERENCE DRAWINGS CONSTRUCTION NOTES SIGNAL TO/FROM OTHER TWO CRU'S SERVING THE LAB. PROVIDE ICOM PANEL AND INTELLISLOT COMMUNICATION CARD FOR THE EXISTING COMPUTER ROOM AIR CONDITIONING UNIT. FANS ON NEW UNITS SHALL BE INSTALLED LOWERED IN THE UNDERFLOOR SPACE. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION RECEIVED CITY OF TUKWILA JUL 1 5 c`3 PERMIT CENTER SIB REV6pN - DEVELOPMENT IAB - 50% IFR WH_12058 A DEVELOPMENT LAB - 90% IFR WH_12058 B DEVELOPMENT LAB - IFC WH_12058 DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 BY WA WH WH WH APPROVED CV CV CV EEL DATE 06.22.12 07.12.12 04.01.13 SYM BY APPROVED DATE 06.20.13 ZiAausrArArce ACCEPTABILITY THIS DESIGN AND/OR SPEQRLA110N IS APPROVED DRAWN 'CRIMPED DATE SUBRRE DETAILS - MECHANICAL CURRENT REVISION 9-12061 SYMBOL C mm 06.20.13 APPROVED BY DEPT. DATE ENUINLLN CHECKED APPROVED APPROVLD • INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SHEET M311 JOB NO. COMP NO. 9-12061 DWG NO. 9-53.1-M311 COMPUTER ROOM COOLING UNIT (CRU) SCHEDULE MARK N - LOCATION ."' _,B ' TYPE NOMINAL CAPACITY . FAN COIL COOLING CAPACITY CHILLED WATER HUMIDIFIER ELECTRIC REHEAT COIL AIR FILTER REMARKS , CAPACITY ESP CAPACITY MB' R,. TEMP 'F. FLOW EWT LWT MA% PD ® A ,O H2. CAP EAT F TYPE & • EFFICIENCY , . 52 MAX P GPM MAX PD FT WATER PREFILTER FINAL FILTER CR1BB6 H3 LAB (ITDL) SELF CONTAINED 30 15 17,100 0.2 352 331 75 61 72 45 55 25 22.1 9.6 102,390 5-24x31 45 (MERV 11) 0.3 LIEBERT CW106DC, FLOOR MOUNTED CR2BB11 HI LAB SELF CONTAINED 12 2.0 5250 0.3 94.5 109.8 75 62.5 22 45 55 9.4 11.0 4.8 ! --- 4"X 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2CC8 K4 LAB SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 7.5 17.4 6.4 --- 6-18x244" 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2CC7 K3 LAB F SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 7.5 17.4 6.4 -- 6-18 x24 30 0.6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2CC4 500 SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 7.5 17.4 6.4 --- 6-18x244" •30 0.6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2BB6 H3 LAB (ITDL) SELF CONTAINED 30 30 18,000 0.2 434.5 434.5 70 57 - - - - 22 9.6 107,000 10-148024 45 0.3 LIEBERT DSE DA125A, FLOOR MOUNTED, DOWN -FLOW CR3BB6 H3 LAB (ITDL) SELF CONTAINED 30 30 18,000 0.2 434.5 434.5 72 57 - - - - 22 9.6 107,000 10-18X24 45 0.3 LIEBERT DSE DA125A, FLOOR MOUNTED, DOWN -FLOW ...,.....1\--/ NV V V/.,P7UVI,L FAN COIL UNIT (FC) SCHEDULE MARK NUMBER LOCATION SERVED TYPE TOTAL STAT.PR. IN. WG CFM MOTOR COOLING DATA HEATING DATA FILTER DATA MANU./MODEL REMARKS HP* RPM MBH TOTAL MAX FACE VELOCITY EAT 'F I AT 'F EW'T F LWT 'F GPM MAX PD FT WATER MBH TOTAL EAT F LAT F EWT F LWT 'F GPM MAX PD FT WATER PREFILTER FINAL FILTER FACE VEL. FPM DB WB DB WB FC2CC1 FIRST FLOOR COOLING 5.0 23,500 30 1750 598 580 77.0 62.7 56.7 54.2 45 55 120 10 --- --- --- --- --- --- -- FARR 30/30 / FARR IOW1Y RIGAF 500 TRANS/41H 30" AIR FOIL WHEEL FC2BB1 SECOND FLOOR COOLING 5.0 19,000 30 1750 610 540 77.1 61.5 52.7 50.7 45 55 122 10 --- --- --- --- --- --- --- FARR 30/30 FARR 12" RIGAFLOW 500 35K TRANE/35K 24.5" AIR FOIL WHEEL FC2CC2 FIRST FLOOR HEATING 4.0 11,750 15 1750 --- --- --- --- --- --- --- --- --- --- 366.5 75 101 170 140 25 1.0 FARR 30/30 FAFARR 12" RRI OW 500 TRANE/218 22" FC WHEEL FC2BB2 SECOND FLOOR HEATING 4.0 9,500 15 1750 --- --- --- --- --- --- --- --- --- --- 397.0 75 109 170 140 27 1.0 FARR 30/30 2" RIGFARRAFLOW 1 500 TRANS/218 22" FC WHEEL • ' 460V/30/60HZ CHILLE -- -- I LE MARK NUMBER TYPE CAPACITY TONS MAXI KW FAN MOTORS SUMP HEATER REMARKS FLOW GPM EWT 'F LWT 'F `� PASS. MAX PD • FOULING •; REFRIG FLOW GPM EC 'F NO MAX PD F �'� 4'E NG FACTOR REMARKS CH1B-2 SCREW 280 208 750 53 44 3 24.43 41 "-22 900 75 8 20.52 .00025 TRANE RTHA 300, LONG SHELL OR APPROVED END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 COOLING TOWER (CT) SCHEDULE MARK NUMBER GPM EWT 'F LWT 'F AMBIENT AIR FANS FAN MOTORS SUMP HEATER REMARKS F DB 'F WB NO. TYPE CFM NO. HP* NO. KW CTRB-2 900 94 85 85 68 3 CENTRIF. 49770 1 @10 1 5 BALTIMORE AIR COIL VXTN215 OR APPROVED (SPECIAL ORDER) CAST IRON BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 • 460V/30/60HZ PUMP (PMP) SCHEDULE MARK NUMBER SERVICE FLUID TEMP 'F CAPACITY SIZE (IN) CONSTRUCTION PERFORMANCE MOTOR PUMP TYPE MANUFACTURER AND MODEL REMARK GPM TDH SUCT DISCH BODY FITTINGS E9 NPFT R DRIVE TYPE HP' RPM PU1B-1A CHW WATER 53' 750 40 5 4 CAST IRON BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 • 460V/30/60HZ NOT INCLUDED IN PHASE 3 CONTRACT, (WILL BE REQUIRED FOR FUTURE PHASE 4 ADDITION) CONSTRUCTION NOTES PROVIDE NEW EQUIPMENT REMOVE EXISTING COMPUTER ROOM UNIT AND INSTALL NEW COMPUTER ROOM UNIT FURNISHED BY BOEING. PROTECT EXISTING COMPUTER ROOM FROM DAMAGE AND DELIVER TO LOCATION AT DEVELOPMENTAL CENTER AS DIRECTED BY BOEING CONSTRUCTION MANAGER. STU A B C D RLWSUN BY Al LAB REVISION MIC RECORD DRAWING DEVELOPMENT LAB - 50% IFR WH_12058 DEVELOPMENT LAB - 90% IFR WH_12058 DEVELOPMENT LAB - TIC WH_12058 MIC WH WH WH APPROVED KMR ILL KMR /R13TV CV CV DATE SYLI REVISION 9.7.90 8.30.91 06.22.12 DEVELOPMENT EAB - ECN-01 WH_12058 N< WH APPRCNED CEL DATE 06.20.13 07.12.12 04.01.13 g;LArznc-,Af ACCEPTABILITY THIS DESIGN MN/OR SPECIFICATION IS AP APPROVED BY DEPT. LD WALT CHECKED pygm W.OENCKEL DATE D.MEYER (DATE REVIEWED FOR CODE COMPLIANCE APPROVED ,JUL 9 4 2013 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FOR CONSTRUCTION SUBDUE SCHEDULES JUL 1 5 2013 DERMIT CENTER CURRENT REVISION 9-12061 SYMBOL F DATE 06.20.13 W.HENCKEL APPROVED K.RAMSEY APPROVED L LAW 5.17.90 DT'E INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SHEET M360 OB NO. 9-12061 COMP NO. DWG NO. 9-53.1-M360 SUBDUE SCHEDULES JUL 1 5 2013 DERMIT CENTER CURRENT REVISION 9-12061 SYMBOL F DATE 06.20.13 W.HENCKEL APPROVED K.RAMSEY APPROVED L LAW 5.17.90 DT'E INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SHEET M360 OB NO. 9-12061 COMP NO. DWG NO. 9-53.1-M360 sYM AIR DIFFUSER/REGISTER/GRILLE SCHEDULE MARK NUMBERINCHES DESCRIPTION MATERIAL FINISH FACE SIZE INLET/ NECK SIZE INCHES MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD -1 SQUARE CEILING DIFFUSER STEEL WHITE 12x12 60 20 .060 140 CARNES SJTA CD -2 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 80 21 .110 275 CARNES SJTA CD - SQUARE CEILING DIFFUSER STEEL WHITE 24x24 100 24 130. 425 CARNES SJTA CD -4 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 120 23 .127 550 CARNES SJTA CD -5 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 140 29 240 950 CARNES SJTA CD -6 ROUND CEILING DIFFUSER STEEL WHITE 240 80 26 .08 260 CARNES SSAA CD -7 ROUND CEILING DIFFUSER STEEL WHITE 300 100 26 .07 315 CARNES SSAA CD -8 ROUND CEILING STEEL WHITE 400 140 24 .03 750 CARNES SSAA RG -1 rE^��i1"NN^GG'ER[2DJ�CEEEIUNG STEEL WHITE 24x24 80* 21 .04 550 CARNES SPRB222 RG -2 PRpERFORATE6 CEILING STEEL WHITE 24x24 120 20 .03 800 CARNES SPRB222 IUNG ii:W1G-3^ R STEEL WHITE 12x24 -- --- 20 022 300 CARNES SPRB222� E�'� Q-1 E ,RAGRII """ EXHAUST GRILLE STY- -WHY- / afES.''� �� N 44.I �/ .U/ "VA ES CARNES If7LAMN/NP-Nr- 1• FSD-1 FLOOR SUPPLY DIFFUSER STEEL WHITE 24x24 .03 1500 TATE DIRECT AIR, SEE M450 FOR DAMPER QTY ) PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTION (INCHES) REMARKS SAN VENT HW CW P-1 WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE P -1A WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE (HANDICAP) P-2 URINAL 2 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE P-3 LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED P -3A LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED (HANDICAP) P-4 SERVICE SINK 3 2 1/2 1/2 FLOOR TYPE P-5 ELECTRIC WATER COOLER 1 1/4 1 1/4 - 1/2 WALL MOUNTED (HANDICAP) P-6 SINK 2 1 1/2 1/2 • 1/2 - P-7 EMERG EYE WASH 1 1/4 1 1/4 - 1/2 - FD -1 FLOOR DRAIN 2 2 - - - FD -2 FLOOR DRAIN 2 - - - W/ FUNNEL FS -1 FLOOR SINK 6 3 - - FLOOR SINK V()` EXHAUST FAN (EF) SCHEDULE MARK NUMBER LOCATION AREA SERVED (ROOM NO.) EXHAUST FAN SECTION REMARKS FAN SIZE MFG. SIZE NO. ARRNGMT.NUMBER (' MAX) TOTAL STATIC PRESS INCHES WG MAX. OUTLET VELOCITY FPM APPROX. RPM DRIVE SIDE INLET GUIDE VANES MOTOR HP EFRCC10 ROOF TOILET ROOM(S) 18' CRE -18F - 2650 3/4 1400 510 - - 1 GREENHECK LB -18-10 W/ BIRD SCREEN AND B.D. EFRCC3 ROOF STORAGE 9' CRE -9F - 875 3/4 1550 1029 - - 1/2 GREENHECK LB -10-5 W/ BIRD SCREEN AND B.D. EF2CC2 FAN ROOM FIRST FLOOR 44' 44 1 20,000' 1.5 1620 771 - - 10 TRANE MODEL 0, AXIAL FLOW EF2BB2 FAN ROOM SECOND FLOOR 40' 40 1 16,200' 1.5 1480 852 - - 7.5 TRANE MODEL 0, AXIAL FLOW 0.30 35 4 100 4 100 8x6 4 TITUS DESV ) DOMESTIC HOT WATER HEATER (HWH) SCHEDULE MARK NUMBER KW INPUT TANK STORAGE GALLONS STADMEP RECOVERY ELECTRICAL REMARKS GPM d VOLTS/PH/HZ HW -1 9 65 ASME 37 100 480/3/60 A.O.SMITH MOD. DSE-65 HW -2 1.5 6 — 6 100 120/1/60 A.O.SMITH MOD. DEL -6 100-300 0.30 35 6 300 4 150 10x8 5 TITUS EDV -3100 W-3 200-600 0.30 35 8 600 VARIABLE AIR VOLUME TERMINAL UNIT (VAV) SCHEDULE MARK NUMBER AIR QUANT. RANGE CFM PRIMARY AIR PRESSURE DROP AT MAXIMUM INCH WG MAX. NC LEVEL ® 1.5' WG INLET COOLING HEATING DISCHARGE DUCT REMARKS SIZE (INCH) CFM INLET SIZE CEM SIZE SOUND UNE LENGTH FEET W-1 0-150 0.30 35 4 150 4 100 8x6 4 TITUS EDV -3100 W-2 100-300 0.30 35 6 300 4 150 10x8 5 TITUS EDV -3100 W-3 200-600 0.30 35 8 600 6 300 12x10 6 TITUS EDV -3100 W-4 300-900 0.30 35 10 900 8 450 14x12 7 TITUS EDV -3100 410 10 W-6 0-150 0.30 35 4 100 4 100 8x6 4 TITUS DESV CONDENSING UNIT SCHEDULE MARK NUMBER INDOOR UNIT LOCATION TYPE SERVICE CONDITIONS FANS ELECTRICAL REMARKS THR MBH AMBIENT DB TEMP DEG F REFRIGERANT TYPE TYPE NUMBER OF FANS AIRFLOW CFM KW VOLTS PHASE HZ ACCU-1 CR2BB6 OUTDOOR AIR COOLED CONDENSER 360 95 R410A PROP 4 37730 2 460 3 60 UEBERT MCL220 ACCU-2 CR2BB6 OUTDOOR AIR COOLED CONDENSER 360 95 R410A PROP 4 37730 2 460 3 60 UEBERT MCL220 PUMPED REFRIGERANT ECONOMIZER MARK NUMBER INDOOR UNIT OUTDOOR UNIT LOCATION SERVICE CONDITIONS ELECTRICAL THR MBH AMBIENT DB TEMP DEG F REFRIGERANT TYPE KW VOLTS PHASE HZ REMARKS PRE -1 CR2BB6 ACU -1 OUTDOOR XXX XXX R410A 3.2 460 3 60 LIEBERT PRE PRE -2 CR3886 ACU -2 OUTDOOR XXX XXX R410A 3.2 460 3 60 UEBERT PRE BY APPROVED 1E SY APPROVED DR A RECORD DRAWING DROPPED CLGS RMS 12653 & 11M4 DEVELOPMENT LAB - 50% IFR WH_12058 MJC KMR /613 8.30.91 F HARR 09/07/11 G WH GV 06.22.12 DEVELOPMENT LAB - ADDENDUM 3 WH_12058 WH GV 04.12.13 DEVELOPMENT LAB - ECN-01 WH_12058 WH DMD 06.20.13 DEVELOPMENT LAB - 90% IFR WH_12058 WH CV 07.12.12 DEVELOPMENT LAB - IFC WH_12058 WH CV 04.01.13 elLAFAVEZAW? CONSTRUCTION NOTES PROVIDE NEW EQUIPMENT REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION ACCEPTABILITY THIS DESIGN MND/OR SPECIFIGTWV R APPROVED APPROVED BY DEPT. DATE LDE WALT CHECKED W.HENCKEL CHE.MCKEREEK CHECKED W.HENCKEL .RAMSEY L LA SUBTITLE SCHEDULES INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER CURRENT REASx*I SYMBOL 9-12061 SHEET 5.17.90 MECHANICAL MASTER JOB NO. D6` No DEV. CENTER, WA 9-53.1-M361 06.20.13 M361 MAINTAIN ALL REQUIRED ACCESS AREAS, TYP 0 O 7/8 RL \ 7/8"RL /� / ' ) I I L 1-3/ 8'R 1-3 8'R /i : % ` 0 0 1 -3/8"RL 7/8 RL 7 7/8"RL 0 1-3/8"RS 1-3/8 RL CONCRETE HOUSEKEEPING PAD, SEE STRUCTURAL 1-3/8"RS 1-3/8"RS 1-3/8"RS 1 -3/8"RS 1-3/8"RL 1-3/B"RL 1-3/8"RL 1-3/8"RL PIPE SUPPORT . ICCTU / M450 DDC PANEL NETWORK SWITCH AND SITELINK 7/8'RL 1-3/8"RL 1-3/8'RL --i r--1 __JL__JL__J L__ M450 f50 1 • T!P C1f 8Q LL- -1W-5",., W-5\ 1 ~ ig 1 � TO VAV TERMINAL ri `=1_ UNIT, SEE 1M13 CD<1 1111111 III■ DDC SENSOR IN COLD AISLE ■ (CEILING MOUNTED) -'----1- I I 1 i • L-- I,,II I~ ♦~72' (MIN) --1 I / \ I I BETWEEN RACKS L___ -L I -._----- I I I FSD-1, I I I TYP OF 24 I- I -I • RACK -MOUNTED SENSOR, TYPICAL —O f134I I 1 T I- I I I 4R IN i I COLD AISLE r - - - H (CEILING MOUNTED)I TO DDG S11{{STEM FOR MON RING 11261 ENLARGED PLAN SCALE: 1/4" = 1.-0' 1M13,1M14 M450 SUN A REVISOR BY *CREWED DAT[ rn REVISION DEVELOPMENT LAB - 50% IFR WH_12058 WH LV 06 22 12 DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 BY WH DATE DUD 06.20.13 DEVELOPMENT LAB - 90% IFR WH_12058 WH CV 0712 12 B DEVELOPMENT LAB - IFC WH_12058 WH DEVELOPMENT LAB - ADDENDUM 3 WH_12058 WH DEVELOPMENT LAB - RFI -08 WH_12058 9-12061 WH CV CV CCL 04 01 13 04 12.13 06.11.13 pBOEOA/G® DRAWN ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVCD___LNDwEw APPROVED BY DEPT. DATE CHECKED 'DATE (BB.5 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 410 City of Tukwila BUILDING DIVISION (BF3 RECEIVED CITY OF TUKWILA JUL 152013 PERMIT CENTER LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. 3. FOR SYSTEM PIPING DIAGRAM, SEE M450 M504 .4. FOR CONTROL DIAGRAM, SEE M311 REFERENCE DRAWINGS CONSTRUCTION NOTES TEMPERATURE SENSORS AT EACH RACK. CONNECT TO COMPUTER ROOM UNIT iCOM CR2BB6 CONTROL SYSTEM. LOCATE TEMPERATURE SENSOR AND LEAK SENSOR BELOW THE RAISED FLOOR. SAVE FLOOR TILES REMOVED FOR PLACEMENT OF THE FLOOR SUPPLY DIFFUSERS. INSPECT ALL FLOOR TILES FOR CRACKS, DAMAGE, CABLE AND PIPE PENETRATIONS. REPLACE DAMAGED TILES, AND SEAL ALL PIPE, CABLE AND CONDUIT PENETRATIONS AIRTIGHT. START/STOP AND SMOKE DETECTORS ON NEW UNITS, BY DDC. ® NEW COMPUTER ROOM AIR CONDITIONING UNITS. SPACE SENSORS MONITORED BY DDC SYSTEM. REMOVE EXISTING UPFLOW CRU AND INSTALL NEW DOWN -FLOW CRU CR1BB6, FURNISHED BY BOEING. TURN EXISTING CRU OVER TO BOEING. MINIMUM CLEARANCE AREA IN FRONT OF COMPUTER ROOM UNITS. ® TAB CONTRACTOR SHALL PROPORTIONALLY CLOSE DAMPERS WHERE RACKS ARE NOT FULL AND COMPLETELY CLOSE DAMPERS WHERE FLOOR SUPPLY DIFFUSERS ARE IN FRONT OF FUTURE RACKS. CONTINUE TO CLOSE ALL DAMPERS WHILE ALL COMPUTER ROOM SUPPLY FANS ARE IN 100% OPERATION UNTIL 0.3 INCH W.C. OR 45,000 CFM IS MEASURED MEASURE UNDER FLOOR PRESSURE AT THE LOCATION OF THIS NOTE. PROVIDE FIRST FOUR FLOOR SUPPLY DIFFUSERS IN EACH ROW WITHOUT OPPOSED BLADE DAMPERS. ® TEMPERATURE SENSORS AT EACH RACK. CONNECT TO COMPUTER ROOM UNIT ICOM CR3BB6 CONTROL SYSTEM. PROVIDE ADDITIONAL CABLE TYPE LIQUID SENSOR CONNECT TO CR1886. 35 FT IN LENGTH. ® go 7000 a030®1+' EMS 1190 B -DG 9- 53 I 0 KEY PLAN NDT mSuE FOR CONSTRUCTION SUBTRIE ENLARGED PLAN 4 2 0 2 4 8 �._ SCALE: 1/4" = 1'-0" CURRENT RENSKM 9-12061 Srvea E DATE 06.20.13 CHECKED APPROVED APPROVED TRs INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. BB-CC/6-5 DEV. CENTER, WA SHEET M450 JOB NO. 9-12061 COMP NO. DwG N0. 9-53.1-M450 SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE 16 GA SHEET METAL WIDTH OF UNIT, COO SEISMIC SUPPORTS SECTION SCALE: 1/4" = 1'-0" (B M450 M451 BB 5 SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE 11111=11111•111111•1•1111:-.- 16 GA SHEET METAL SCOOP, HALF WIDTH OF UNIT, COORDINATE WITH SEISMIC SUPPORTS TYPICAL SEISMIC SUPPORT PROVIDED WITH THE UNIT SECTION SCALE: 1/4" = 1'-0" I- i 1-3/8"RS 7/8"RL ii CRY BB FANS IN UNDERFLOOR PLENUM I 1 1 M450 M451 III SYN REVISI N Bf APPR0,ED DATE SU BY APPROVED DAlI - DEVELOPMENT LAB - 50% IFR WH_12058 WH CV 06.22.12 A DEVELOPMENT LAB - 90% 116 WH_12058 WH GV 07.12.12 8 DEVELOPMENT LAB - 1FC WH_12058 WH GV 04.01.13 C DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH CEL 06.20.13 0___AiL7E7ArG® REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES vim, -v - INSTALL AND COMMISSION 30 -TON DOWN -FLOW CHILLED WATER COMPUTER ROOM UNIT, FURNISHED BY BOEING. PROVIDE AIR SCOOP AND SUPPORT FRAME. RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION ACCEPTABILITY �""" DATE SUBTITLE 195 DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED APPROVED By DEPT. DATE CHECKED MECHANICAL SECTION 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CURRENT RENSRIN SYMBOL DATE 9-12061 C 06.20.13 APPRDVCD TRIS INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 SHEET M451 JOB NO. COMP NO. 9-12061 9-53.1-M451 MECHANICAL MASTER COL. BB-CC/6-5 DEV. CENTER, WA "G HD 7/8"RL Ai + 1 -3/8"RS 7/8"RL 1 CI CSR CR DDC PANEL SEISMIC SUPPORT PROVIDED SCOOP, HALF RDINATE WITH VOPAI WITH THE UNIT SECTION SCALE: 1/4" = 1'-0" (B M450 M451 BB 5 SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE 11111=11111•111111•1•1111:-.- 16 GA SHEET METAL SCOOP, HALF WIDTH OF UNIT, COORDINATE WITH SEISMIC SUPPORTS TYPICAL SEISMIC SUPPORT PROVIDED WITH THE UNIT SECTION SCALE: 1/4" = 1'-0" I- i 1-3/8"RS 7/8"RL ii CRY BB FANS IN UNDERFLOOR PLENUM I 1 1 M450 M451 III SYN REVISI N Bf APPR0,ED DATE SU BY APPROVED DAlI - DEVELOPMENT LAB - 50% IFR WH_12058 WH CV 06.22.12 A DEVELOPMENT LAB - 90% 116 WH_12058 WH GV 07.12.12 8 DEVELOPMENT LAB - 1FC WH_12058 WH GV 04.01.13 C DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH CEL 06.20.13 0___AiL7E7ArG® REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES vim, -v - INSTALL AND COMMISSION 30 -TON DOWN -FLOW CHILLED WATER COMPUTER ROOM UNIT, FURNISHED BY BOEING. PROVIDE AIR SCOOP AND SUPPORT FRAME. RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION ACCEPTABILITY �""" DATE SUBTITLE 195 DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED APPROVED By DEPT. DATE CHECKED MECHANICAL SECTION 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CURRENT RENSRIN SYMBOL DATE 9-12061 C 06.20.13 APPRDVCD TRIS INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 SHEET M451 JOB NO. COMP NO. 9-12061 9-53.1-M451 MECHANICAL MASTER COL. BB-CC/6-5 DEV. CENTER, WA "G HD 4 PCD TERMINATE 2" ABOVE THE BOTTOM OF THE FLOOR SINK 1/2" CW 3/4" CD /77...---113UILDING EXTERIOR WALL RL RL RS RS ACCO ACLU 1-3/8'RL—\9 ALL PIPE PENETRATIONS SHALL BE SEALED AIRTIGHT (E)FLOOR SINK 1/2" FULL PORT BALL VALVE, WITH CAPPED HOSE CONNECTION UNDERFLOOR PLENUM SUPPORT CHANNELS, SPACED AT 3 FEET 1-3/8"RL 1-3/8"RL� 8'-0" 1-3/8"RL 1-3/8"RL� 7/8"RL 7/8"RL Ifir 7/8'RL 7/8"RL EXIST. FLOOR REF. ELEV. 0,-0" FULL PORT BALL VALVE 7/8"RL 1-3/8"RS COMPUTER ROOM UNIT PIPING DIAGRAM rm SCALE: NTS 1M113, 1M114, M311, M450 M504 ..o C C 2 2 1/2"0 HILTI KWIK BOLT II MIN EMBED 3 1/2' (INTO EXIST CONCRETE), TYP FOR BASE PLATE DETAIL SEES M50,41504 5/8" x 4' x 4' 1/4 A36 STEEL PLATE PIPEINSULATION (TVP) / [PIPE CLAMP (TVP) 1-3/8"RL LC 1-3/B"RL L�� 1-3/8"RL %1-3/8"RL 1-3/8"RS 1-3/8"RS 1-3/8'RS 1-3/8"RS PIPE SUPPORT SCALE: NTS M45� 4 CONCRETE PAD NON -SHRINK GROUT SYM REMSIDN BY APPROVED DATE SYR BY APPRENED DATE DEVELOPMENT LAB - 50% IFR WH_12058 WH EN 06.22.12 A B DEVELOPMENT LAB - 90% IFR WH_12058 WH OV 07.12.12 DEVELOPMENT LAB -IFC W11_12058 WH cv 04.01.13 DEVELOPMENT LAB - ADDENDUM 3 WH_12058 WH GV 04.12.13 D DEVELOPMENT LAB - ECN-01 WH_12058 WH CEL 06.20.13 TS 4 X 4 X 1/4 1 1/4' TYP. CONCRETE PAD, SEE STRUCTURAL O DRILL FOR 1/2"0 HILTI KWIK BOLT TYP. 5/8' x 8' x 8' A36 STEEL PLATE BASE PLATES SHALL BE POSITIONED ON THE NEW EQUIPMENT PAD. POSITION THE PLATES SUCH THAT THE CENTER OF THE PLATES IS AT LEAST 9 INCH FROM THE EDGE OF THE PAD. BASE PATE SCALE: NTS M504 M504 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION giLATISFAEZAW ° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED INICH ATTACH TO STRUCTURE (TVP 22 GAUGE GALVANIZED STEEL HARD DUCT LONG RADIUS ELBOW, SEGMENTED ELBOWS ARE NOT PERMITTED INSULATION EQUALIZING GRID SUPPORT AT MIDPOINT OF FLEX HANGER STRAP FLEX DUCT -SAME SIZE AS DIFFUSER INLET OR AS INDICATED ON FLOOR PLANS (5' MAX LENGTH AND 45' TURN ANGLE) SUPPLY DUCT I i L OUND DIFFUSER 1111111111 NECK LAY -IN CEILING CEILING DIFFUSER, CDT CELING DIFFUSER CD1 PROVIDE FLEX DUCT WITH ROLL BACK AND CLAMP ALL CONNECTIONS SO THAT NO FIBERGLASS IS EXPOSED SCALE: NONE FOR CONSTRUCTION CHECKED APPROVED BY DEPT. DATE 'CHECKED SUBHDE DETAILS - MECHANICAL RECEIVED 1M15 4Y OF TUKWILA JUL 1 5 2013 PERMIT CENTER CURRENT REVISION 9-12061 SYMBOL D wTE 06.20.13 APPNOLED APPROVED TITLE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET M504 JOB NO. 9-12061 CORP NO. DCG ND. 9-53.1-M504 EXISTING 3' BUTTERFLY (2) 3' x 2 RED. EL (2) 3' 4 BOLT FLANGE (2) 2' BLK RAISED FLOOR LEVEL 1 1/2 QUICK DISCONNECT PETE'S PLUGS (SW. 4) 1 1/2' STRAINER (TYP OF 2) CONNECT TO A/C W/ 1 1/2' FDAALE COPPER SWEAT x 1 1/2' FPT BRONZE ADAPTER. ISOLATION VALVE 1 1/2' SUPPLY & RETURN DETAIL SCALE: NTS '11,150,612.),161 cos CeR 1' ISOLATION VALVE 1' CHWS & CHWR 1' STRAINER W/20 MESH SCREEN AND DRAW VALVE W/ GARDEN HOSE CONNECTION & CAP I' UNION 3/4' REDUCER 2 -TON 1' ISOLATION / SPOT COOLER VALVE , 'LIEBERT', 208 V, 1 0, 60 N SEE DWG, 109-053-4033 M-1 FOR COMPLETE DESCRIPTION HOSE BIBB WITH CAP ON HOSE CONNECTION BOTH SUPPLY A RETURN (TYPICAL) P- TRAP Op ROUTE TO EXIST. FLOOR SINK (SEE PLAN) SPOT COOLER ISOMETRIC SCALE: NTS SEE 682111CTURN DWG A -SAN FOR STRUCTURAL SUPPORT i)f'CHWS U('CHWR RAISED FLOOR LEVEL D ETAI L 3 SCALE: NTS 1M64 1M506 1M114 g)LATAPEZAWe ACCEPTABILITY TH5 DESIGN MID/OR SPECRKATION 15 APPROVES APPROVED BY DEPT. DATE DRAWN S.REYNOLDS MIL O LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES REMOVE EXISTING A/C UNIT CR1BB6 AND DISCONNECT ALL ASSOCIATED PIPING. RECONFIGURE EXISTING PIPING AND RE -CONNECT TO NEW CR1BB6. INSTALL AND COMMISSION NEW CR1BB6, FURNISHED BY BOEING. RE -USE EXISTING PIPING AND DEVICES AND RECONFIGURE FOR INSTALLATION AT NEW CR1BB6. INSTALL ALL DEVICES (VALVES, STRAINERS, PETE'S PLUGS, BALANCING VALVE) IN AN ACCESSIBLE LOCATION. BALANCE VALVE SETTING SHALL REMAIN UNCHANGED, REPORT SETTING AND PRESSURE DROP. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FOR CONSTRUCTION 5.19.88 CHECkED SUBTITLE PIPING DETAILS JUL 1 5 2013 PERMIT CENTER CURRENT REASON 9-12061 SYMBOL D GATE 06.20.13 tLAIWAILLIA S.ROSS.ROSSE 5.19.88 CHECKED D.E.L 5.20.88 APPROVED APPROVED E.CARRIGAN 5.20.88 INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET 1M506 JOB NO. 11181858 COMP NO. INC NO. 9-53-1M506 BY APPROVED) INCE BY APPROVED DATE SOW REVISION SW CONVERSION FROM MYUR TO CAD CCSI 12.10.00 - A RELOCATE NCO LAB - 120110-00 RWS 'RNS 09.02.03 '--' B DESIGN ACOUIRE/INSTALL 30TON UEBERT 11181858 M.WONG RWS 10.26.10 C Y1 AND UT17 LAB UPGRADES WH GV 09.07.12 D DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 001 EEL 06.20.13 g)LATAPEZAWe ACCEPTABILITY TH5 DESIGN MID/OR SPECRKATION 15 APPROVES APPROVED BY DEPT. DATE DRAWN S.REYNOLDS MIL O LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES REMOVE EXISTING A/C UNIT CR1BB6 AND DISCONNECT ALL ASSOCIATED PIPING. RECONFIGURE EXISTING PIPING AND RE -CONNECT TO NEW CR1BB6. INSTALL AND COMMISSION NEW CR1BB6, FURNISHED BY BOEING. RE -USE EXISTING PIPING AND DEVICES AND RECONFIGURE FOR INSTALLATION AT NEW CR1BB6. INSTALL ALL DEVICES (VALVES, STRAINERS, PETE'S PLUGS, BALANCING VALVE) IN AN ACCESSIBLE LOCATION. BALANCE VALVE SETTING SHALL REMAIN UNCHANGED, REPORT SETTING AND PRESSURE DROP. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FOR CONSTRUCTION 5.19.88 CHECkED SUBTITLE PIPING DETAILS JUL 1 5 2013 PERMIT CENTER CURRENT REASON 9-12061 SYMBOL D GATE 06.20.13 tLAIWAILLIA S.ROSS.ROSSE 5.19.88 CHECKED D.E.L 5.20.88 APPROVED APPROVED E.CARRIGAN 5.20.88 INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET 1M506 JOB NO. 11181858 COMP NO. INC NO. 9-53-1M506 • PERMIT COORD COPYI PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-131 DATE: 07/15/13 PROJECT NAME: BOEING #9-53 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AWCI Ie."( Building Division Public Works Awe ,qwc, 9-i3 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IP Comments: Incomplete El DUE DATE: 07/16/13 Not Applicable ❑ Permit CenterUse Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/13/13 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Prig, Friendly Page r General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AUBURN MECHANICAL INC UBI No. 600074968 Phone 2538389780 Status Active Address Po Bbx 249 License No. AUBURMI163BA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 1/1/1984 State WA Expiration Date 9/12/2014 Zip 98071 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUBURMI184LAAUBURN MECHANICAL INC Construction Contractor Plumbing Unused 6/1/1982 1/1/1984 Archived Business Owner Information Name Role • Effective Date Expiration Date THODAY, DAVID V President 01/01/1980 Amount JOHNSON, STACY ANNE President 01/01/1980 DTC08057R723PHX12 JOHNSON, KIM PAUL Secretary 02/06/2009 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FIDELITY E DEPOSIT CO OF MD LPM8047218 09/01/2001 Until Cancelled $12,000.00 09/12/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 29 Phoenix Insurance Company, The DTC08057R723PHX12 10/01/2012 10/01/2013 $1,000,000.00 09/25/2012 28 Phoenix Insurance Company, The DTC08057R723PHX11 10/01/2011 10/01/2012 $1,000,000.00 09/20/2011 27 PHOENIX INS CO DTC08057R723PHX10 10/01/2010 Until Cancelled $1,000,000.00 09/27/2010 26 Continental Western Ins Co CWP258632926 10/01/2009 10/01/2010 $1,000,000.00 10/05/2009 25 CONTINENTAL WESTERN INS CO CWP258632923 09/01/2008 09/01/2009 $1,000,000.00 08/28/2008 24 CONTINENTAL WESTERN CWP2586329 09/01/2005 09/01/2008 $1,000,000.00 08/13/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httos://fortress.wa.gov/lni/bbin/Print.asnx 08/02/2013