HomeMy WebLinkAboutPermit M13-132 - NORDSTROM - ALTERATIONNORDSTROM 100 SOUTHCENTER MALL M13-132 City of tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROM Permit Number: M13-132 Issue Date: 08/20/2013 Permit Expires On: 02/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: DUNCAN OSBORN Address: 1600 7 AV #2500 , SEATTLE WA 98101 Email: DUNCAN.F.OSBORN@NORDSTROM.COM Contractor: Name: R & H CONSTRUCTION CO Address: 1530 SW TAYLOR ST , PORTLAND OR 97205 Contractor License No: RHCON**194P0 Phone: 206 454-5553 Phone: 503-228-7177 Expiration Date: 07/29/2014 DESCRIPTION OF WORK: REPLACE EXISTING GREASE DUCT WITH LARGER UNIT AND FAN (TYPE I), ENLARGE EXISTING GREASE DUCT FAN, AND ADD SPLIT SYSTEM AIR CONDITIONING UNIT TO KITCHEN. Value of Mechanical: $84,000.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $1,196.63 International Mechanical Code Edition: 2012 Date: D 3 I hereby certify that I have read and ami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, hether specified herein or not. The granting of this permit does not pre n e to give authority to violate or cancel the provisions of any other state or local laws regulating constructio = the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back oft Signatur Print Name: Ouvtfrgine - Date: -13 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. A/1/1 nn1A_1-49 Printed• 08-20-2013 PERMIT CONDITIONS Permit No. M13-132 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: Readily accessible access to roof mounted equipment is required. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job sit8 at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: Maintain proper UL 300 fire protection system nozzle coverage and interlocking of exhaust fans and make up air. Any modifications needed require a separate Tukwila Fire Dept. permit. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IMC -4/10 M13-132 Printed: 08-20-2013 CITY OF TUKWA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www,TukwilaWA.gov •: Mechanical .1'erntit No r pate-Applicat;on Accepted: „age` App1ipatidg Ezpir* ,•. For. office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: /0 D 5'00/4 N Tenant Name: /1/0/Qj)5MOM ,fPROPERTY-OWNER' Name: OMMy t/7'_1.LC , Address:two° ,tit" * tZ,SirV Address: lt60I Lai W140. A14-0> City: fivc 1A06000.3 State: GA- Zip:, pp 2s - CONTACT PARSON - Person gceivtpg'alI prQ}eat comma icafion .:t:ro r r :1:::V y .. ' '': t,. `. Name: p \i/ocividosaoRA) Address:two° ,tit" * tZ,SirV City: / w State: Zip: 4101 Phone:7,06 . i, . no Fax: /006. itpt. 12 Lam! Email:%AhC214 #f: nSLorik a ittOrci s'f rOAP L King Co Assessor's Tax No.: 7Z 0Z-4/7 — 0/30 Suite Number: /1//4' Floor: -3 New Tenant: ❑ Yes JO.. No $1 MECU-4iN[CAL''CONVTI AGTOR1NFO &ATION` F '; Company Name: PSF Mechanical, Inc. Address: 9322 14th Avenue South City: Seattle State: WA Zip: 98108 Phone: (206) 764-9663 Fax: (206) 762-8381 Contr Reg No.: PSFMEI*090NZ Exp Date: 10/03/2013 Tukwila Business License No.: 0102293 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Re° V $i7a)6 &RB'NScr 14 Cr W )Th I bf- '.4 fl 44 FM/ elution' oMJS�v�a%V Nu4- Jl AO spur S'tsi\rt' ,hR cel bbn I T' k iTGtw elf) trot) 00 Use: Residential: Commercial: Fuel Type: Electric New ❑ Replacement ❑ New ® Replacement Gas ❑ Other: H:\Applications\Forms-Applications On Linc120 II ApplicationslMechanical Permit Application Revised -9-I l .docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type .. ..:..: Qty `.. Furnace <100k btu Furnace>100k btu 2 Floor furnace 1 Suspended/wall/floor mounted heater 1 Appliance vent 1 Repair or addition to heat/refrig/cooling system Air handling unit 1 <10,000 cfm Unit Type .. Qty; Air handling unit >10,000 cfm Evaporator cooler 2 Ventilation fan connected to single duct 1 Ventilation system 1 Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial UnitType Qty Fire damper Diffuser 2 Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment ..: Boilet1Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 3 0-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PtRMIT.APPL•ICATION NOTES • Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R • '• ! ; ZED AGENT: ! , Signature: 1 Date: 7 S� 3 Print Name: butt Cl?,9441 Mailing Address: "° lt" !NW 251)V H:\Applications\Fonns-Applications On Line\20I 1 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Day Telephone: City Z0644S• C. .33 w* 9 e(t State Zip Page 2 of 2 11 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.uov RECEIPT Parcel No.: 9202470010 Permit Number: M13-132 Address: 100 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/16/2013 Applicant: NORDSTROM Issue Date: Receipt No.: R13-02147 Payment Amount: $1,196.63 Initials: JEM Payment Date: 07/16/2013 01:14 PM User ID: 1165 Balance: $0.00 Payee: DUNCAN OSBORN, NORDSTROM INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 016327 ACCOUNT ITEM LIST: Description 1,196.63 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 957.30 000.345.830 239.33 Total: $1,196.63 rinr• Rcrcint-!1A Printed: 07-16-2013 INSPECTION RECORD Retain a copy with permit ,113-13 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proje t: l ISS 1 Q %SIM Type of Inspection: Fl tJ A L.. -- Address: 100 S0 n)411 Date Called: Special Instructions: Date �an�ted:� t' �, 73ate. '7 Requester: Phone No: a3-758-6 ®,Approved per applicable codes. Corrections required prior to approval. f COMMENTS: N and .5 Wirt- - 87,4410 I@ -P (nip /sem r,A 0 1111 R NSPECTION FEE RQUIRED. Prior to next inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: r��/L1/ 15 INSPECTION RECORD Retain a copy with permit X13—)32 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 g_ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 1\.,101Zi""k01'✓N Type of Inspection: F-71)\-)1___ ci • Address: 1 0 SC i1A1t Date Called: _t (€3) C/6%)"4"- '1- •--- Ak,c+1 Special Instructions: qAwl Date Wanted: 10 — Z— 1723 ...> p.m. Requester: u✓-4' ?/%,.. 0E7e• Phone No , n -758-599 -Approved per applicable codes. !�J Corrections required prior to approval. COMMENTS: Q A 1 + ci • z., 1ZLictir\ —.1 - 04 - S* - it jos Loci ht 4t »4 • A/e /- _t (€3) C/6%)"4"- '1- •--- Ak,c+1 `'I i i 1104L11isa t ►l-GZ,.• - .-1? t/ 1J p CP 7\0E -1 N 0&t OfcbC, io is iaNkto VrC Tv Q.UNA/Q'J 00>E r4Ave -2 IP AliZ1Hirj 0 C C y 1.7e $44 pi u✓-4' ?/%,.. 0E7e• Date: Io -Z -I3 RI IISPECTION FEEftEQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ‘. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431.-3670 Permit Inspection Request Line (206)431-2451 M13-%32_ Project: WOtk G s iktvh Type of Inspection: r---NAL:f' Address: IOC) c O'LIT4.-fie F,Tiep SNt A \. Date Called: Special Instructions: _ Date Wa ed: ' tReque am,. Pm. r:I Phone No: 03-758-5CS.I, 'Approved per applicable codes. t�J Corrections required prior to approval. Is- . COMMENTS: sc heart, l l: A t tTspettor: n REINSPECTION FEE RciUIRED. r to next inspection., fee must be pai`d at:6300 Southcenter' Blvd.. Suite 100. Call to schedule reinspection. Date: ' 11 /l Prib INSPECTION RECORD Retain a copy with permit INSPECTION NO. ; PERMIT NO. ,MI3-1?2_ CITY OF TUKWILA BUILDING DIVISION C' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: 4\jc)r, S7/�) Type of Inspection: .` .. N ,�e, �-4: (6,PJ , i . E Address: ( O 0 S c AAA -i Date Called: p/A-,, Special Instructions: Date Wanted- — !� r lf' J asu,. P.m. Requester: Phone No: 7.,0C — �- 307--5,->" e L c .f -J ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: \\ p/A-,, .. 3.9_ PS, jJ RRR e. (///(/\� e (tom(/ '‘, e L c .f -J Q 7 Ot AJ) / ire -11-A/N 2) Insp tor: 0, Date l / 13 n REINSPECTION FEE REQUIRED Prior to next inspection. fee must be paid at 6300 Southcenter Blvd\, uite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IF. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M13 -/32.. Pro ct: 0/ 5 �� /41� Typggof Inspection: a v 6 4- 3 t� lu Address: (00 Sc �A l( Date Called: �� j (4T /c Special Instructions: R 1 ` Lc1+�• Date Wanted: q -. c -- (�2 e--r-i.` . p.m. ;P Co '-eft.;E..0J cr /Alt e-`•?yp. ,�- 1 Requester: Phone No: 1,.$0(a . 3 d 7 — 3i S 6-' JApproved`per applicable codes. COMMENTS: Corrections required prior to approval .3 ./) ,re...(- d r Date: 7-7-7— / -_ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection; INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: / or 04 Siro04 S Type of In pection: Wo® / /fec 4 1:57i /70i l Address: Suite #: /CD S G Mod f Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: / 00ti ,/- :e f -'e i a4,01a PcX �-/� r -;`,,a f- ©/< IlOO C nhec old fire r2 lain,' 5141(5. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector -3(f, pm 5 T Date: /d i/7/ 3 Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: • City: State: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: lVv�dS�� C;� Sprinklers: T p of Inspection: r -p Address: /6-, 0 5. c . Suite #: 4_,. Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1\104 Cep f r e J../ vv S r 9/o /2e,v.e� C p w►, �, - - aa�, d 9/9.5-113 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /oit„cv,,(---z_ Date: /of L /0 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 MAYES TESTING ENGINEERS 20225 Cedar Valley Road, Suite 110 Ph 425.742.9360 Lynnwood, WA 98036 Fax 425.745.1737 10029 S. Tacoma Way, Suite E-2 Tacoma, WA 98499 7911 NE 33n° Drive, Suite 190 Portland, OR 97211 INSPECTOR TIME Daniel Quehl Ph 253.584.3720 Fax 253.584.3707 Ph 503.281.7515 Fax 503.281.7579 HOURS SUMMARY: Page 1 of 1 FIELD COPY / SUBJECT TO REVIEW Project No.: T-13181 Date: 9-19-2013 Project: Nordstrom Southcenter Cafe Permit No.: -V4105102414 Weather: sunny Project Address: 100 Southcenter Mall Tukwila, WA Owner: Nordstrom Engineer: PSF Mechanical Architect: Contractor: PSF Mechanical Type of Inspection: Light Test for Grease Ducts Samples: None Inspector arrived on site as scheduled by the contractor for a Light Test on 22" diameter 16 gauge Grease Ducts (welded black steel indoors and stainless steel outdoors). These Grease Ducts were located from the Roof Area down to the upper level storage area and then into the kitchen from grid lines A to C/9 to 10. This inspection was performed as the contractor placed light inside of the Grease Duct at each welded connection. Inspector then as the area around the duct was dark verified that there were no pin holes at the welded locations. After this inspection was completed inspector verified that there were a total of 4 pin holes in the Roof Area and 5 pin holes in the Upper level storage area. These holes were then marked and welded by the contractor. These locations were then inspected to assure that each hole had been filled. RECEIVED CITY OF TUKWILA OCT 0 4 2013 PERMIT CENTER To the best of our knowledge, all items inspected today are in conformance with approved plans and specifications. x YES NO PRELIMINARY INSPECTION MODEL KA FILE COPY Permit No. 3/4" Flange 1'ReeOar Outlet OM DELS 1-5/8"f Min. I— (` 1-1/2" I --+ T T I i0 Standard ® mom imi i ,_ Optional' . �: ' 2-3/8" 1.518" Min. 16" Max: Max. 521_, Rear � } Outlet I r - IMC STAT = Or Grease Cup H Optional Z --t---Y W 45° Front Model KA Pitch On Top 6" Corner I-- moo Switch Package J.B. FAI" i 1 W ® ® Model KA -1 Optional Hanger Brackets For Switch L Light In Recess 1/2" Dia. Threaded Rods Package 1' Optional Rear Outlet T .1 U Exhaust ® ® U ® 2-3/8" 1-5/8" Min. x 17-51x" 15" Max. Max. X T Model KA -3 Pitched T --..--1----..--1--- Z T ; Z+ Y H Y W j- Model KA -P 1 ® • J.B. ® ® ® NSF Approved Bottom o Edges On Front Optional X Y Switch Cover Plate1/2 L ) Package 1/2 L 1/ J L Quantity Model 1®Material 02 GaugeL. Hood Dimensions Q3 Number of Lights Bottom Edge Type W H 1 KA 304SS 18 84 48 24 2 Y ®Factory Cut Exhaust Opening ©Filters ©Finish O7 Side Other Skirts Tag U X Y Z Type Material Quantity Size 3" 14" 12" 36" BAFFLE ALUM 3 16" X 20" #3 3" E vo 1 16" X 25" • . Coln: nNy3 ®Q Type 304 or 430 stainless steel. © #3 polish standard.®18 ga. is standard: other gauges available. 07 Advise if one or both sides. Make a sketch; 133 Standard is 100 watt vapor proof incandescent U.L. Listed 8 Optional exhaust air fire damper. for use on grease exhaust hood. ®9 Optional switch package with surface mounted stainlend ;:t.,:::111-iliAaN 4 Two collars required on hood sections over 12' long. junction box on top of hood. (Fan switch : ith illu nd5 Aluminum baffle type U.L. Classified filters standard. ID Hood mounted ❑ Loose for wall ouuntinj•a Number of light switches SU ING DU.L. File MH 12960 (Without Exhaust Fire Damper) Number of fan switches Voltag= ■ fel DWI .'l1 US LISTED DU.L. File MH12071 (With Exhaust Fire Damper) �rt� aS To maintain KEES' policy of continuous product development, we reserve the right to change p ices, specifications, ratings and dimensions without notice or obligation. Project NORDSTROM SOUTHCENTER CAFE Location TUKWILA, CA Engineer PSF MECHANICAL KEES INCORPORATED 400 S. Industrial Dr. • P.O. Box L 4�45s Elkhart Lake, WI 53020 Phone: (920) 876-3391 Architect CALLISON D1nrg. No. SD -KA Contractor PSF MECHANICAL Date 06/10 65 Fax: Website:ewww.k876-3ees.com www.kees.com l3- ADJUSTABLE TEMPERATURE SWITCHES TSW Series -41!;,17:1r1-:!*N'lr-C!, tWe'La•F! gr.Feelf4:1..F4F,V4i.Tir TSW-11, shown actual size. • v Compact and Economical v Ideal for Economical Temperature Switching Applications v External Temperature Scale for Easy Setpoint Adjustments v 1 A Gold Contacts for TTI and Dry Contact Closures V 5 A Silver Contacts for Larger Electrical Loads 1,1 Vibration Resistant OMEGA's TSW Series adjustable temperature switch is perfect for applications that require an economical solution to temperature control. The stainless steel stem of the TSW Series switch is sealed and filled with a gas that expands as process temperature rises. A membrane within the switch body mechanically causes closure of a 5 A Form "C" relay. The 9.7 mm (0.38) diameter of the probe is designed to mate with OMEGA's standard 385 Series thermowells for your most rugged applications. • SPEC.;IFICI-MegF: Temperature Range: -43 to 266°C (-45 to 510°F) Temperature Sensor: Limit filled, saturated vapor sensor Ambient Temperature Limits for Switch Body: -55 to 105°C (-67 to 221°F) Max System Temperature Capillary: 425°C (797°F) Max System Pressure: 68.9 bar @ 425°C (1000 psi CO 798°F) Electrical: 1 A Rated Contacts: 115 Vac/28 Vdc 5 A Rated Contacts: 250 Vac/28 Vdc Max Switch Cycle Rate: Not to exceed 20 cycles per minute Wiring Code: Black = common, white = normally open, red = normally closed Construction Materials Wetted Parts: Temperature Sensor: 316 SS Non -Wetted Parts: Body: 303 SS Lock Ring: Zinc alloy, chromate finish Switch Housing: Zinc alloy, chromate finish Caps and Accessories: Black valox and brass terminals Indicator: 303 SS Indicator Ring: Black nylon Wire Interface: 3 -wire pigtail, furnished 300 mm (12) long, 20 AWG insulated with PVC, 300 V rating Weight: 113 g (0.25 Ib) ,,,,, ,ner,eeseiPITiernIMP-ro.T..!! e`-.`,'•ei7137e'r-1..r'7,:erktert.c7117.7.1re're54r-Wit:370..15-1.4iTAIWIreiMP.."' -11,1r 1461 (*75)._ 171.5 • Ditnensions:-mni (In) • MOST POPULAR MODELS HIGHUGHTED! Accessories N.1.15.4014.010.0,40P-': 2 :: q*iiigt0.4F•t:4;:g2-44:4-111-1r:1 3/4-385S-U21/2-304SS rife,f1V-- Stainless steel thermowell .-4'" -,SWLZIPMT:giM:'M:1'*k:T.,Viggt*iltit sirk-05001,TALW:24--14f: :.f3Orffesg015Falfir-; ilgige:4011, %'.j!( ' PiM-.,... TS1;/-11 Stainless steel compression fitting -45 to -5 (-49 to 23) 1 ±0.7 (1.3) TSV/ -15 -45 to -5 (-49 to 23) 5 ±0.7 (1.3) TSW-21 -25 to 20 (-13 to 63) 1 ±0.9 (1.6) TSW-25 -25 to 20 (-13 to 63) 5 ±0.9 (1.6) TSV/ -31 -5 to 35 (23 to 95) 1 ±0.8 (1.4) tSW-35 , - .:: 45 tO 35 (23 to,95 - : 5 . A..8(1A) TSW41 ' - • '. 254670.(77to_158) - 1 TSW-45 .25 to 70 (77 to 158) 5 ±0.9 (1.6) TSW-51 55 to 105 (131 to 221) 1 ±1.0 (1.8) TSW-55 55 to 105 (131 to 221) 5 ±1.0 (1.8) TSW-61 80 to 125 (176 to 257) 1 ±.9 (1.6) TSW-65 80 to 125 (176 to 257) 5 ±.9 (1.6) TSW-71 115 to 175 (239 to 347) 1 • ±1.2 (2.2) TSV/q4 ..-.)15,i0 175 (239Ttb847). : 1:5 ' ,E.-.1.43 (23)S.:, TSW-81 175 to 230 (347 to 456) 175 to 230 (347 to 456) 1 5 ±1.2 (2.1) ±1.2 (2.1) TSW-85 TSW-91 200 to 265 (392 to 509) 1 ±1.3 (2.4) TSW-95 200 to 265 (392 to 509) 5 ±1.3 (2.4) Accessories N.1.15.4014.010.0,40P-': 2 :: q*iiigt0.4F•t:4;:g2-44:4-111-1r:1 3/4-385S-U21/2-304SS Stainless steel thermowell 3/4 -385S -U21/2 -BRASS Brass thermowell SSLK-38-12 Stainless steel compression fitting ..l311141<::38-12... ' ' •• Brass..cOmpressipn:fitting Comas with complete operator's manual. Other therrnowells available; see Section B. Ordering example: TSW-71, adjustable temperature switch with a 115 to 175°C (239 to 347°F) range, 1 A contact rating and 3/4-385S-1,121/2-304SS, stainless steel thermowell dese r, ,-,ereeseru men, ceee. •A'A e er.-eerre ,v ter, reete *ter e e a • A 1 .M1 A VA ..r..cr4sants! Trim angles at wall for top enclosure TOP ENCLOSURE, END. SKIRTS AND BACK -SPLASH DETAILS Advise type ceiling (Ceiling Detail "A" or"B") 24" HT. FOR ALL EXPOSED SIDES AT HOODS HD-1, HD -2 AND HD -3 INCLUDES 35 ADDITIONAL AT SIDES OF CLASS 1 . HOODS TO ACCOUNT FOR WALL SPACER. CEILING Top Enclosure WALL MOUNTED HOOD (Side View) End Skirt Baok-Splash Baseboard Back -splash, with all edges hemmed, Is full width of hood from bottom edge of.hood to baseboard (or floor). End skirts have front and bottom edges hemmed. WALL End Skirts . WALL MOUNTED HOOD (Plan View) Top enclosures, back -splashes and end skirts mount with exposed sheet metal screws or rivets 113" on center, fasteners by others. WALL. Back -Splash WALL MOUNTED HOOD (Plan View) • 3 -sided top enclosure ISLAND HOOD (Plan View) J Z 4+sided top enclosure Advise typo Ceiling (Detail "A" or"B") CEILING Top Enclosure ISLAND 11000 (Side View) 1 CEILING DETAIL "A" CEILING OD Ceiling trim angle H plaster or drywall. —. — Fasteners by others. (Typ.) FILING DETAIL "B" Top enclosure ext:nds3» above calling If lay -In typo, CEILING HOOD Revision to this detail: bottom leg of enclosure panel to have 90 degree return to the Inside for concealed fastening: Fasteners by others. Project Location Engineer Architect Dwg. No. SD -SBS Contractor Date 2-03 KEES INCORPORATED f �(++ 400 S. Industrial Cr.Dr. P.O. Box L /fdapliJ� Elkhart Lake, WI 53020 / Phone: (920) 876-3391 Fax. (920) 876-3065 Website: www.kees.com Specification: Kees Model KA Exhaust only class 1 kitchen hood: Provide KEES Model KA wall hung (or KB Island style) exhaust only hood(s) constructed of 18 gauge (16 gauge) type 304 stainless steel having a #3 polish of sizes as indicated. All exterior seams shall be continuously welded, liquid tight as required by U.L., and ground an polished to match the original finish of the material. Hood(s) shall be fabricated in accordance with National Fire Protection Associated (NFPA) Bulletin No. 96, shall be National Sanitation Foundation (NSF) Listed and bear the NSF seal, and shall be Underwriters Laboratories (U.L.) Listed and U.L. labeled as required. U.L. Listed exhaust air fire dampers shall be provided if required by local code. The lull length filter housing with pitched grease trough shall be of 18 gauge, type 304, #3 polish stainless steel complete with removable stainless steel grease container. Filters shall be U.L. Classified, 2" thick baffle type constructed of aluminum (or stainless steel). Lights shall be U.L. Listed incandescent vapor proof 100 watt type on approximately 3 foot centers (or U.L: Listed fluorescent fixtures) pre-wired to a junction box on top of the hood. Wiring shall conform to the National Electric Code (NEC). For more details, refer to KEES catalog KAB. pcz,c8) KEES, INC. Products for Sheet Metal HVAC, Food Service, & Architectural Construction Industries 400 S.INDUSTRiAL DRIVE - P.O. BOX L- ELKHART LAKE, WISCONSIN 53020 - (920) 076-3391 - FAX (920) 876.3065 KITCHEN HOOD INSTALLATION AND MAINTENANCE MANUAL RECEIPT AND INSPECTION Upon receipt check carefully for any shipping damage to the carton, crate and hood. Verify that all items as listed on the Bill of Lading have been received. Repoit any damage or shortage to the carrier Immediately so that any required claim can be processed. STORAGE if storage is required, KEES recommends storing in a finished building or warehouse. If stored outside, take care to suitably protect the unit from dirt, moisture, corrosion, damage, etc. INSTALLATION The installation of this hood is to be in accordance with NEPA 96, Standard for Ventilation Control and Eire Protection of bomrnercial Cooking Operations. NEPA 96 has a number of installation requirements including minimum clearances to "limited -combustibles" and "combustibles". Consult NEPA 96 and all applicable local codes before installing the hood. Remove hood crating but do not remove protective plastic film until hood has been Installed. Place protective material between any equipment used to move or support the hood during installation to prevent damage to the finish of the hood. Threaded hanger nuts for W threaded rod are provided as shown at each corner of each hood section. 12' hood sections are also provided with 2 loose intermediate support brackets for field location and mounting to hood. If rods cannot be provided directly in the required locations, hang fieldsupplied support bars across the hanger nuts with the hood supported from the support bars. J_- I-1' (TYR, EACH CORNER) a t° (TYP., EACH CORNER)-). PLAN VIEW OPTIONAL FIELD SUPPLIED SUPPORT BAR ACROSS HOOD pcms) KESS, INC. Products for Sheet Metal HVAC, Food Service, & Architectural Construction industries 400 S. INDUSTRIAL DRIVE - P.O. BOX L ELKHART LAKE, WISCONSIN 53020 - (920) 876-3391 - FAX (920) 876-3065 interconnect hood and exhaust fan with duct constructed, Installed and Isolated from any "combustible" or "limited combustible" surfaces in accordance with NFPA 96 and all applicable local codes. If hood is an "energy saving" or "tempered air" hood with supply air plenum, interconnect hood and supply fan with duct in accordance.wlth local codes. Insulate ductwork and install balancing and/or control dampers as desired or as required by local codes. Install U.L. Listed fire extinguishing system in accordance with NFPA 96 and all applicable local codes. AIR BALANCE For satisfactory system performance, the hood fan(s) must be balanced by qualified personnel. Refer to separate KEES Balancing Manual Form # BALM for additional information. OPERATION, MAINTENANCE AND CLEANING Operate, inspect, clean and maintain the hood, duct(s), fan(s) and fire extinguishing system in accordance with NFPA 96, local health and safety codes, and instructions supplied with any of the system components. Hood filters, all hood surfaces, ductwork and fans should be cleaned frequently to prevent excessive grease accumulation. The fire extinguishing system should be tested periodically as recommended by the manufacturer and in accordance with NFPA 96 and all applicable local codes. WARRANTY KEES warrants the hood(s) and all hood components supplied for a period of 1 year from date of shipment to be without defects in material and workmanship. Any unit(s) which prove to be defective during the warranty period will be repaired or replaced at KEES option when returned to our factory, freight prepaid. KEES will not be responsible for any removal or installation costs. UL -HI 08/98 1111PERMIT COORD COPY 1 PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-132 DATE: 07/16/13 PROJECT NAME: NORDSTROM SITE ADDRESS: 100 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division • Fire Prevention • Public Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07/18/13 Complete 74j Incomplete n Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/15/13 Approved ❑ Approved with Conditions 15ir Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Ptin,,, Friendly Page / • General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name R Et H CONSTRUCTION CO UBI No. 600417535 Phone 5032287177 Status Active Address 1530 Sw Taylor St License No. RHCON"194P0 Suite/Apt. License Type Construction Contractor City Portland Effective Date 10/20/1981 State OR Expiration Date 7/29/2014 Zip 972051819 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company NOR -AM CONSTRUCTION Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RHRESCC994M4 R Et H RESIDENTIAL CONST CO Construction Contractor General Unused 7/24/2001 7/16/2014 Active RHRESC'996M3 R & H RESTORATIONS COMPANY Construction Contractor General Unused 7/23/2001 7/29/2014 Active Business Owner Information Name Role Effective Date Expiration Date BRADLEY, JOHN W Chief Executive Officer 10/20/1981 Amount WARD, JOHN C President 08/02/2010 GL0369667310 DOWTY, NORMAN Vice President 08/02.'2010 GUNSOL, DAVID B Vice President 08/02/2010 Zurich American Ins Co WILLIAMS, RANDALL J Vice President 10/20/1981 FULTON, ROBERT Treasurer 01/01/1980 08/02/2010 HOLMES, JOAN M Treasurer 01/01/1980 08/02/2010 Bond Information Page 1 of 2 Bond Bond Company Name 8 FEDERAL INS CO Bond Account Number Effective Date 81394622 07/10/2002 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount Received Date $12,000.00 07/10/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 28 Zurich American Ins Co GL0369667310 07/10/2013 07/10/2014 $1,000,000.00 07/09/2013 27 Zurich American Ins Co GL0369667310 07/10/2012 07/10/2013 $1,000,000.00 07/09/2012 26 Zurich American Ins Co GL0369667308 07/10/2011 07/10/2012 $1,000,000.00 07/06/2011 25 ZURICH AMERICAN INS CO GL03696673 07/10/2010 07/10/2011 $1,000,000.00 07/09/2010 24 ZURICH AMERICAN INS CO GL03696673 07/10/2009 07/10/2010 $1,000,000.00 07/08/2009 23 ZURICH AMERICAN INS CO GL03696673 07/10/2005 07/10/2009 $1,000,000.00 07/01/2008 httos://fortress.wa.gov/lni/bbip/Print.aspx 08/20/2013 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Mr.': Revisions will require a new plan submittal and may include additional plan review fees. 1 SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION BT Q 8x8 A.C. AIR CONDITIONING UNIT A.D. AIR DOOR A.F.F. ABOVE FINISHED FLOOR B.D.D. BACKDRAFT DAMPER B.S. BIRD SCREEN B.O.G. BOTTOM OF GRILLE B.O.D. BOTTOM OF DUCT B.T. BYPASS TIMER CENTER LINE CUH CABINET UNIT HEATER CO CO2 0 D.S. CARBON MONOXIDE SENSOR CARBON DIOXIDE SENSOR DIAMETER DISCONNECT SWITCH D.T.S. DUCT TEMPERATURE SENSOR D.G. DOOR GRILLE DRAWING NOTE D DUCT DROP IN DIRECTION OF ARROW R DUCT RISE IN DIRECTION OF ARROW DN. DOWN E.C.H. ELECTRIC CEILING HEATER E.D.C. ELECTRIC DUCT COIL E.F.C. ELECTRIC FAN COIL E.U.H. ELECTRIC UNIT HEATER E.C. ELECTRICAL CONTRACTOR ELEVATION EXIST. EXISTING E.A. EXHAUST AIR E.F. EXHAUST FAN EXT. EXTERIOR OR EXTERNAL F.I.T. FAN INDUCTION TERMINAL F.D FIRE DAMPER F.S.D. F.O.B. F.O.T. F.T.U. F.C. G.C. 200 A H.P. INT. M.U.A. M.U.F. FIRE/SMOKE DAMPER FLAT ON BOTTOM FLAT ON TOP FAN TERMINAL UNIT FLEXIBLE CONNECTION GENERAL CONTRACTOR NECK SIZE (INCHES) GRILLE, REGISTER, OR DIFFUSER TYPE AIR QUANTITY (CFM) HEAT PUMP OR HORSEPOWER INTERLOCK MAKE-UP AIR MAKE-UP AIR FAN MD (AC -XXX) /// 9 POc R RB \ • 1, I ❑ SD WAIVVVN 0 SP i \\ rl M.C. M.D. NOM. MECHANICAL CONTRACTOR MOTORIZED DAMPER MECHANICAL EQUIPMENT TAG NOMINAL O.B.D. OPPOSED BLADE DAMPER ORIFICE SIZE (INCHES) O.A. OUTSIDE AIR OV. OVAL P.B.D. PARALLEL BLADE DAMPER P.O.C. POINT OF CONNECTION R. RELOCATE R.A. RETURN AIR R.B. REBALANCE R.A.G. RETURN AIR GRILLE R.V.D. REMOTE VOLUME DAMPER RETURN DUCT DOWN RETURN DUCT UP SIDE INLET CAN S.D. SMOKE DETECTOR S. DMPR. SMOKE DAMPER S.P.F. SMOKE PURGE FAN S.S.S.C. SOLID STATE SPEED CONTROL S.L. SOUND LINING SQUARE TO ROUND DUCT TRANSITION S/S START/STOP STATIC PRESSURE SENSOR S.A. SUPPLY AIR SUPPLY DUCT DOWN SUPPLY DUCT UP SW. SWITCH T.C. TEMPERATURE CONTROL T.S. TEMPERATURE SENSOR T'STAT. THERMOSTAT TOP INLET LAY -IN T.O.D. TOP OF DUCT T.F. TRANSFER FAN T.V. TURNING VANES U.D. UNDERCUT DOOR V.A.V. VARIABLE AIR VOLUME TERMINAL VOLUME DAMPER V.D. 181 roe WIRE GUARD COVER OVER TEMPERATURE SENSOR WIRE GUARD COVER OVER THERMOSTAT GENERAL NOTES 1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA AND THE, ! INTTEi RATIONAL MECHANICAL CODE to: • IMC). , 2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT. 4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW DUCTS REQUIRING INSULATION: A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR. B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE. C. OUTDOOR, EXPOSED SUPPLY AND RETURN. ITEMS NOT REQUIRING INSULATION: A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE. B. FACTORY -INSULATED FLEXIBLE DUCTS. C. FLEXIBLE CONNECTORS. D. VIBRATION -CONTROL DEVICES. E. FACTORY -INSULATED ACCESS PANELS AND DOORS. 5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM 6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC., REQUIRED TO INSTALL MECHANICAL SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 8. POWER WIRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. 9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL. 10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS. 11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK. 12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED. 13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR EXACT ELEVATIONS AND DIMENSIONS. EXISTING EXISTING NEW NEW NEW EXISTING 15. CONTACTORS, MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE. 16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2009 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416. Zb I 17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THEWASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3-1416.2.6.3. 18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2009 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2-1416.2.3. 19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W/IBC, IMC & SMACNA SEISMIC STANDARDS. 20. PROVIDE PIPE INSULATION PER 14-6 WSEC. 21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC. 22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICAL SYSTEMS PER WSEC TABLE 14-4. 23. EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT. 24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS PART OF THE TENANT IMPROVEMENT PROJECTS. 25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5°F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. 26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. 27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS. 28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. 29. ALL GREASE DUCTS SHALL BE SLOPED MINIMUM 1/4" PER FOOT BACK TOWARDS HOOD OR APPROVED GREASE RESERVOIR. 30. PROVIDE CLEANOUTS AND ACCESS OPENINGS IN GREASE DUCT PER 2009 IMC, SECTION 506.3.8. Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (20A4 IMC 107.2.4 & IMC 506.3.2.5) VICINITY MAP FILE COPY Permit No. V1I3q- 132- inn lrt+iew`approval Is subject to errors and omissions. �►; ...;1 of construction documents does not authorize t�...:�' elion of any adopted code or ordinance. Receipt of 1 31?rrwed • t i condlfons isadmowwledged: • Date: Z() - t -c PARTIAL FAN SCHEDULE �(j {{ tall Iujj��jj MARK MFR.IMODEL UNIT LOCATIONFl�GCSOC AREA SERVED CFM SP HP RPM POWER D.S. INCLUDED (LBS) WGHT. REMARKS FLOOR GRID SIS TC EF -20 COOK 1195 CPV ROOF RPM KITCHEN HOODS HD-1, HD -2 (TYPE 1 GREASE HOODS) 4800 1.50 3 1,566 460V/3PH NO 480 o TRANE I BWC090F4 1, 2, 3, 4, 5, 6 RESTAURANT / KITCHEN 7.5 3,000 1.25" 1.5 835 - - - - 450 460V/3PH - 35 MCA MUA-3 GREENHECK / BCF -207 3RD B/9.5 HD-1 COMPENSATING HOOD 1840 0.50 3/4 1,403 460V/3PH RESTAURANT / KITCHEN r,, 3,160 1 1. START EXHAUST/MAKEUP AIR FANS PRIOR TO STARTING AC UNITS FOR THIS AREA. 2. UL762 LISTED FOR GREASE EXHAUST, DRAIN, 9:00 POSITION ACCESS DOOR, WEATHER COVER AND SEISMIC SPRING ISOLATION. 3. ADJUSTABLE DRIVES. 4. ELECTRICAL CONTRACTOR TO PROVIDE MAGNETIC MOTOR STARTER. 5. CLEARANCE BETWEEN TOP OF ROOF CURB AND FINISHED ROOF TO COMPLY WITH THE LOCAL CODE 6. UPWARD DISCHARGE, CLOCKWISE ROTATION REVIEWED FOR `CODE COMPLIANCE APPROVED 'JUL 9 4 2013 City of Tukwila BUILDING DIVISION PARTIAL AC UNIT SCHEDULE MARK MFR. I MODEL UNIT LOCATION AREA SERVED NOM. TON EVAP. FAN EXHAUST FAN MIN OSA CFM POWER D.S. INCLUDED AMPS HEATING WGHT. MIN. EFFIC. EMCS FUNCT REMARKS FLOOR GRID CFM SP HP RPM CFM SP HP RPM (mv) MBH SIS TC HP -3 TRANE I BWC090F4 ROOF RESTAURANT / KITCHEN 7.5 3,000 1.25" 1.5 835 - - - - 450 460V/3PH - 35 MCA 1500 # 8.9 rER , 1 HP -4 TRANE / BWC090F4 ROOF RESTAURANT / KITCHEN 7.5 3,160 1.25" 1.5 835 - - - 450 460V/3PH - 50 MCA - 1500 # 8.9 EER o c:, 1 FC -4 MITSUBISHI / PEAD-A30AA THIRD A / 6.5 KITCHEN 2.5 850 0.40" 121 W - - - - - - 208-230/1 PH NO 2.73 MCA - 80 # 16.5 SEER - . 2 CU -4 MITSUBISHI 1 PUZ-HA3ONHA2 ROOF C.3 / 6.5 KITCHEN (FC -4) 2.5 - - - - - - - - - 208-230/1 PH NO 28 MCA - - 265 # 16.5 SEER - - 3 1. W/ OVERSIZED MOTOR, HORIZONTAL DISCHARGE, BAY 28x138 T'STAT. 2. INDOOR UNIT W/ MEDIUM STATIC PRESSURE CAPABILITY, BUILT-IN DRAIN FOR CONDENSATE REMOVAL, AIR FILTER, WIRED REMOTE CONTROLLER, R401A. 3. OUTOOR UNIT: R410A. SEPARATE PERMIT R QUIRED FOR: ❑ Mechanical ®'Electrical I�Plumbing bias Piping City of Tukwila 61.11.1_FING DIVISION DRAWING SCHEDULE DWG. DESCRIPTION RM1.1 HVAC SCHEDULES, SYMBOLS AND GENERAL NOTES RM1.2 HVAC SCHEDULES AND AIRFLOW DIAGRAM CITY UKWILA RM2.1 PARTIAL HVAC FLOOR PLANS JUL RM3.1 HVAC DETAILS AND SPECIFICATIONS 1 6 2013 RM3.2 HVAC SPECIFICATIONS PERMIT CF1vT.rrr, �gF PSFMechanical 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 Collo EXPIRES 12/05/r2t 1 L I STAMP coco r �o CD c • Q W zY W O t- J Q o� ce v, C w G ~ O z w cc U O o zcT2 J W D 0 w M r O N W LL U SiviftnAti- (9.210. l3 KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 NTS TR MK HVAC SCHEDULES, SYMBOLS AND GENERAL NOTES RM1.1 Sheet: 1 of 5 EXISTING REBALANCE NEW HOOD SCHEDULE MARK MFR. I MODEL HOOD TYPE EQUIPMENT SERVED EXHAUST CFM HOOD SIZE EXHAUST HOOD COLLAR SIZE EXHAUST DUCT SIZE FILTERS FILTER VELOCITY VELOCITY AVG. EFF. TYPE FILTER MAKE/MODEL FAN SYSTEM REMARKS ROUND (IN) RECTANGULAR (IN) QTY (FPM) ROUND (IN) RECTANGULAR (IN) VELOCITY (FPM) QTY. SIZE (IN) EFFECTIVE AREA (SQ FT) HD-1 GREENHECK I (TBD) TYPE I (GREASE) STACKED GAS PIZZA OVENS GAS SIX -BURNER RANGE, GAS BROILER 3,400 102"x48" 3 24 12 1 1700 16 - - 2435 4 20" x 16" x 2" 11.50 296 04BAFFLE RESEARCH P <:.O LI6i' KLEEN +GUAR FF -20 i 3 2 20" x 20" x 2" HD -2 KEES I KA TYPE I (GREASE) STACKED GAS CONVECTION OVENS, SOUP KETTLE 1,400 84"x48"- 95 14 12 1 1200 14 - (BACK -OF -HOUSE) 1310 3 16�� X 20" x 2" 7A9 187 94 BAFFLE RESEARCH PRODUCTS/ KLEEN GUARD EF -20 1, 2, 3, 4 1 16"x 25"x 2" 1. LISTED UNDER U.L. 710-1995. 2. PROVIDE WITH 3" WALL SPACER. 3. PROVIDE WITH 24" ENCLOSURE PANELS FOR ALL EXPOSED SIDES. 4. PROVIDE WITH INTEGRAL TEMPERATURE SWITCH TSW-41. 5. HOOD PROVIDED BY KITCHEN EQUIPMENT SUPPLIER, INSTALLED BY OTHERS, CAFE/KITCHEN AIR BALANCE DIAGRAM 450 CFM OSA L 2,450 CFM H P-3 450 CFM OSA L 2,450 CFM HP -3 ROOF EF -20 4,800 CFM THIRD FLOOR SALES AREA FC -4 MUA-3 3,000 CFM SUPPLY SEATING 1 fi 2,450 CFM 850 CFM SUPPLY SEATING 1,200 CFM* AIRFLOW VIA PERMANENT OPENING TO SALES FLOOR AREA APPROX 107 SQ. FT. (VEL = 11 FPM) r CAFE DINING 1,840 CFM PASS-THRU -� WINDOW �`" 1,560 CFM TRANSFER VIA PASS-THRU WINDOW r-� APPROX 13.5 SQ. FT. (VEL = 116 FPM) cc] REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwi ID a BUILDING DIVISI N 550 CFM 850 CFM HD-1 SUPPLY SUPPLY. 1,840 CFM 3,400 CFM MAKEUP (TYPE I) HD -2 1,400 CFM (TYPE I) M13- (3Z *ALL EXHAUST/MAKEUP AIR IS ACCOUNTED FOR IN THE DESIGN AND BALANCE OF THE MAIN BUILDING'S SYSTEMS. SYSTEMS ARE INTERLOCKED TO OPERATE WITH FANS. KITCHEN SOUTHCENTER CAFE CAFE/KITCHEN AIR BALANCE DIAGRAM RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER Qi7F PSFMechanical= 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 STAMP CO CO 00 C:) Q w J z w� I- I I- I"' J a w G ~ O z W � U I"'- U) 15 LL O DO zo SCD ` P cr to.2lo, 13 KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 NTS TR MK HVAC SCHEDULES AND AIRFLOW DIAGRAM RMI.2 Sheet: 2 of 5 EXISTING HD-1 HOOD CALCULATIONS (KEES HOODS) - REFERENCE ONLY 2012 INTERNATIONAL MECHANICAL CODE FINAL VALUE USED HOOD HD-1 (TYPE I) UNDER THE HOOD EXHAUST REQUIRED (CFM) SIZE BASE EXHAUST (50 CFM/SF) EQUIPMENT TYPE COOK TEMPI DUTY CFMI SOFT. QTY SIZE ADDITIONAL EXHAUST (CFM) CODE SECTION HOOD LENGTH (FT) CFM/ LIN. FT. EXHAUST REQ'D (CFM) HOOD # W (FT) D (FT) W(FT) D(FT) HD-1 8.5 4 1700 NEW 36" GAS PIZZA OVENS, STACKED (SOUTHCENTER #3) MEDIUM -DUTY 37 2 3 3 666 507.13.2 8.5 400 3400 GREENHECK 1 TBD EXISTING GAS 6 -BURNER RANGE (SOUTHCENTER #4) MEDIUM -DUTY 37 1 3 3 333 GREASE NEW 24" GAS BROILER (SOUTHCENTER #5) HEAVY-DUTY 95 1 2 3 570 (BACK -OF -HOUSE) 0 1400 1400 1400 1569 3270 3400 3400 14 CAFE/KITCHEN AIR BALANCE DIAGRAM 450 CFM OSA L 2,450 CFM H P-3 450 CFM OSA L 2,450 CFM HP -3 ROOF EF -20 4,800 CFM THIRD FLOOR SALES AREA FC -4 MUA-3 3,000 CFM SUPPLY SEATING 1 fi 2,450 CFM 850 CFM SUPPLY SEATING 1,200 CFM* AIRFLOW VIA PERMANENT OPENING TO SALES FLOOR AREA APPROX 107 SQ. FT. (VEL = 11 FPM) r CAFE DINING 1,840 CFM PASS-THRU -� WINDOW �`" 1,560 CFM TRANSFER VIA PASS-THRU WINDOW r-� APPROX 13.5 SQ. FT. (VEL = 116 FPM) cc] REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwi ID a BUILDING DIVISI N 550 CFM 850 CFM HD-1 SUPPLY SUPPLY. 1,840 CFM 3,400 CFM MAKEUP (TYPE I) HD -2 1,400 CFM (TYPE I) M13- (3Z *ALL EXHAUST/MAKEUP AIR IS ACCOUNTED FOR IN THE DESIGN AND BALANCE OF THE MAIN BUILDING'S SYSTEMS. SYSTEMS ARE INTERLOCKED TO OPERATE WITH FANS. KITCHEN SOUTHCENTER CAFE CAFE/KITCHEN AIR BALANCE DIAGRAM RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER Qi7F PSFMechanical= 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 STAMP CO CO 00 C:) Q w J z w� I- I I- I"' J a w G ~ O z W � U I"'- U) 15 LL O DO zo SCD ` P cr to.2lo, 13 KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 NTS TR MK HVAC SCHEDULES AND AIRFLOW DIAGRAM RMI.2 Sheet: 2 of 5 NEW HD -2 HOOD CALCULATIONS (KEES HOODS) - REFERENCE ONLY 2012 INTERNATIONAL MECHANICAL CODE FINAL VALUE USED HOOD HD -2 (TYPE I) UNDER THE HOOD EXHAUST REQUIRED (CFM) SIZE BASE EXHAUST CFM/SF) (50D(FT)SECTION EQUIPMENT TYPE COOK TEMPI DUTY CFMI SOFT. QTY SIZE ADDITIONAL (CFM) CODE HOOD LENGTH (FT) CFM! LIN. FT. EXHAUST REQ'D (CFM) HOOD # W (FT) D (FT) W(FT)EXHAUST HD -2 KEES KA 7 4 1400 NEW 36" GAS CONVECTION OVEN, STACKED (SOUTHCENTER #11) LIGHT-DUTY 0 2 3 3 0 507.13.4 7 200 1400 GREASE RELOCATED KETTLE & STAND (SOUTHCENTER #9) LIGHT-DUTY 0 1 2 3 0 (BACK -OF -HOUSE) 0 1400 1400 1400 CAFE/KITCHEN AIR BALANCE DIAGRAM 450 CFM OSA L 2,450 CFM H P-3 450 CFM OSA L 2,450 CFM HP -3 ROOF EF -20 4,800 CFM THIRD FLOOR SALES AREA FC -4 MUA-3 3,000 CFM SUPPLY SEATING 1 fi 2,450 CFM 850 CFM SUPPLY SEATING 1,200 CFM* AIRFLOW VIA PERMANENT OPENING TO SALES FLOOR AREA APPROX 107 SQ. FT. (VEL = 11 FPM) r CAFE DINING 1,840 CFM PASS-THRU -� WINDOW �`" 1,560 CFM TRANSFER VIA PASS-THRU WINDOW r-� APPROX 13.5 SQ. FT. (VEL = 116 FPM) cc] REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwi ID a BUILDING DIVISI N 550 CFM 850 CFM HD-1 SUPPLY SUPPLY. 1,840 CFM 3,400 CFM MAKEUP (TYPE I) HD -2 1,400 CFM (TYPE I) M13- (3Z *ALL EXHAUST/MAKEUP AIR IS ACCOUNTED FOR IN THE DESIGN AND BALANCE OF THE MAIN BUILDING'S SYSTEMS. SYSTEMS ARE INTERLOCKED TO OPERATE WITH FANS. KITCHEN SOUTHCENTER CAFE CAFE/KITCHEN AIR BALANCE DIAGRAM RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER Qi7F PSFMechanical= 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 STAMP CO CO 00 C:) Q w J z w� I- I I- I"' J a w G ~ O z W � U I"'- U) 15 LL O DO zo SCD ` P cr to.2lo, 13 KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 NTS TR MK HVAC SCHEDULES AND AIRFLOW DIAGRAM RMI.2 Sheet: 2 of 5 17.0 KITCHEN HOOD EXH. DUCT (EF -20) 39'x16"-2" 24"x 16"11 (HP -1) `Y' I 3/8" 1.1QUI , 5/8" SUCTION -SEE UPPER LEVEL FOR CONTINUATION ICiRETE - ION 91.7 1/4" - SEE UPPER LEVE _ DE CONTINUATION OPARTIAL ROOF HVAC PLAN - DEMO °' 2' 4' 8' cE) SCALE: 1/8" =1'-0" (CRETE ION E UP. OVE \EL. 91'-71/4" U1FACL, 'X10" NNEC "0 OF "x12" 16 UP. SLOPE DU 1 ORK 1/4" PER FOOT TOWARD EF -20 \ \.� `20"x20" 16 GA WELbED BLACK i/ STEEL DUCT TO KITCHEN\ HOODS (SEE UPPER LEVE 20'x20" STAI (ESS STEEL L DUCT ATA EXTERIOR FOR CONTINUATION) \ x20' } PARTIAL ROOF HVAC PLAN - NEW O SCALE: 1/8" =1'-0" SCJ A4 A4 A4 A4 10x4 1501 I A4 A4 A4 A4 A4 I A4' A4 A4 A4 A41 A4: rte._._ A4A4 ._._ L15`3`'a M I - _ A4I A4I A41 A4i A41 - A4a 1 A4 A41 L A4 A4 1 A 4 I Au --i ---- 1x1 1501M1 A41 A41 A4:I 114A1-- -.1,_ _.' -1T- A41 A41 A4 11 Ari MAKE UP AIR + ION @ HOOD (2 TYP SET DN, TRANS. TO HOOD CONNECTIO WELDED BLACK FOR CONT. & OAF. /SST DN. NNECTION. N PARTIAL CAFE HVAC PLAN - DEMO °' 2' 4' 8' SCALE: 1/8" =1'-0" %MIMIN 0' 2' 4' 8' Cpp YEIIIMI I 12x6 I [365 M , • ,A,- 12x6--• -i 1365 N' 1 A4 A41 A4 I A4 ' _ _ A4 A4[ A4 A4 A4 L A4 A4 Lti -2x6 16A r 8x 140 F BOD @ 1 "0 (EDC -451)48 0 GCE -08x8 �1281H 0 1 6- 365 ----- 1r0 - 12x4 200 M 4T EDC -4-2 (f' 41I_ L Qr ! 411 I 4 [ 4 ri PARTIAL UPPER LEVEL HVAC PLAN - DEMO 0' 2' 4' 8' SCALE: 118" = 1'-O" N N {Ij i 10 11 - 1 --DN -TO.. FC -4 ON- - 3RD N --3RD- FLOOR--_..- -_.. rTh PARTIAL UPPER LEVEL HVAC PLAN - NEW °' 2' 4' 8' Cp N SCALE: 1 /8" =1'-0" A4j 20'x20" KITCHEN rcbD 4 j� SL-¢ EXH. DUCT (E 2" A4 , T/4"- FOOT__ BACK -TO GODS. 200' 4- -144! A4 20"x20" 16 WELDED-\ _As CK STEEL A2 M I 2 1 A4 A4 A4 I L A 1 , A4 i A4 A4 A4 I A4 A4 A4 A4 \ c{E; � A4 � A ! �F I i MS I, A41_ L.14:41 A4 A4 —._ ' 2 4 4 n 4 41 4 4 4- 4I 4 2 41 4i 4 4 4E 2 41 4 4 4 .4 2 4 4! 4 4 2 4T EDC -4-2 (f' 41I_ L Qr ! 411 I 4 [ 4 ri PARTIAL UPPER LEVEL HVAC PLAN - DEMO 0' 2' 4' 8' SCALE: 118" = 1'-O" N N {Ij i 10 11 - 1 --DN -TO.. FC -4 ON- - 3RD N --3RD- FLOOR--_..- -_.. rTh PARTIAL UPPER LEVEL HVAC PLAN - NEW °' 2' 4' 8' Cp N SCALE: 1 /8" =1'-0" A4j 20'x20" KITCHEN rcbD 4 j� SL-¢ EXH. DUCT (E 2" A4 , T/4"- FOOT__ BACK -TO GODS. 200' 4- -144! A4 20"x20" 16 WELDED-\ _As CK STEEL A2 M I A4 ' A4 A4 A A4 A4 A4 [ A4 A A4 A4 A4 M I A4 Ar A4 A4 A4 A4 A4 44 20"x20" DN -nom _.._: A4 - A4 Aro- A4' I \A11..J1S]E ERMAL (,CERAMIC - - - ---. IQEWRAP-"TNSULATIoN-=-]WOA R -F 41 ZERO CLEARANCE TO COMBUSTIBLES L. � 0NTRRAACjfl ' 0 :-PROM RATED- -- } j I ;rt tom. Y L [It - - 4/ PARTIAL UPPER LEVEL HVAC PLAN NEW °' 2' 4' 8' N SCALE: 1/8" =1'-0" \-6/ \Y/ - A ^.,i,111k,1 41.I Re stm TIT 0 \_5/ ,INSTALL SECONDARY DRAIN PAN AND CONDENSATE PUMP BELOW FC -4. INSTALL WATER LEAK DETECTOR ALARM IN SECONDARY DRAIN PAN TO SHUT DOWN UNIT IN CASE MOISTURE IS DETECTED. 0 3/8" LIQUID, 5/8" SUCTION UI5 TO UPPER LEVEL CbNDENSATE PUMP FIELD ROUTE 3/4" CONDENSATE P(PIN¢ TO NEAREST FLOOR SINK. 0 L L) NUMB 4 t-� ii IF' L= 7-15'X10" MAKE UP AIR C NNECTION @ 1000 (2 ;wi) p 16'0 OFtSE1 ON, TRANS. O ; 24"x12' HOOD CONNECDIOEL 1 WARN x O" 161 GA WELDED BLACK 1STEEL OT UP. [N TO 20"x14" P.E111110. x X11 I UCT UP, N TO WELDED BLACK SliErri .L 20"k20" UP. TR�NS Olga OUTT CAFE HVAC PLAN - NEW ' SCALE: 1/8" = V-0" cr7). ‘i'ltif of T kw DIVISION \Y/ \-16/ 132 RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER LEGEND - DEMO ---- EXISTING TO REMAIN NEW DUCTWORK PSFMechanicalY: 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 EXPIRES 12/05/ zo STAMP co co °L3i;-.3 ca 0 I— U) EFJ cn 0 u_ 0 KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 TR MK PARTIAL HVAC FLOOR PLANS RM2.1 Sheet: 3 of 5 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 230713 - DUCT INSULATION PART 1- GENERAL 1.1 SUMMARY A. Section Includes: Duct insulation at the following applications: 1. Exterior of unlined ducts. 2. Duct Interiors where indicated on Drawings. 3. Fire Rated Insulation for Commercial Kitchen Grease Duct, B. Drawings, the provisions of the Agreement, including bonds and certificates, theGeneral Conditions, and Division 01 specification sections apply to all work of this Section. 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): E2336 - Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems, 1.3 QUALITY ASSURANCE A. Standards: All material and workmanship shall comply with applicable local, county, state and national standards. B. Safety: Comply with all rules and regulations of the State's Industrial Accident Commission and NEPA 101. 1.4 SUBCONTRACTOR GUARANTY A. Furnish Subcontractor Guaranties in accordance with Section 017700. PART 2 - PRODUCTS 2.1 DUCT INSULATION A. Manufacturer: Owens -Coming, or equal. B. Thermal insulation: 1-1/2 inch fiber glass, 0.6 pcf, with factory applied foil vapor barrier facing with one 2 inch flange, R = 4.2 min; thickness as scheduled. Tape all joints. C. Soundlining: Owens-Coming"Aerollex type 150"; 1 inch thick blanket duct liner, 1.5 to 3.0 pcf. 2.2 FIRE RATED INSULATION FOR COMMERCIAL KITCHEN GREASE DUCT A. Approved Manufacturers: 1. Thermal Ceramics. 2. Johns Manville. 3. 3M Firemaster, B. Provide type as compliant with ASTM E2336. PART 3 - EXECUTION 3.1 EXAMINATION A, Examine areas and conditions under which mechanical insulation will be Installed, Do not proceed with work until unsatisfactory conditions have been corrected. 3.2 INSTALLATION A, Duct Exterior Insulation 1. Install where ducts are concealed in shafts and above ceilings and where indicated on the Drawings. 2. Wrap insulation tightly on all metal supply ductwork, except that shown as being lined, with ail circumferential joints butted and longitudinal joints overlapped a minimum of 2 inches; tape or seal all joints. 230713-1 0812 1 NORDSTROM-SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 230713 - DUCT INSULATION in return air shafts, lap all joints in direction of air flow and tape all joints. Pin or wire ductwrap on all ducts over 35 inches in width, so that ductwrap stays tight to ducts, Fire dampers do not require ductwrap. Position insulation to facilitate installation of wall angles at fire damper sleeves. All access doors and volume/balancing damper operators, locking quadrants, shafts, and handles shall be exposed, accessible and operable following installation of ductwrap. Slitting insulation (only) at these locations is not acceptable. Cut back insulation and tape around quadrants, 7, Closure systems shall have a 25/50 F.H.C. per UL 723. For rectangular ducts over 18 inch wide, the duct wrap shall be secured to the bottom side of the duct with mechanical fasteners, or equivalent, spaced at 18 incur centers to reduce sag, Care should be taken to avoid over compensating the insulation with retaining deviices. Exterior duct wrap shall be terminated 6 inches from end of duct to allow connection of flex duct, only where flex duct is shown. B, Soundlining: 1. In ll in duct locations as indicated on the Drawings. 2, Install tight to duct interior surface, neatly fitted Into all corners, C. Fire -Rated insulation for Commercial Kitchen Grease Duct For grease ducts inside the conditioned building envelope, but not in rated enclosure, install two-hour fire rated blanket wrap to meet manufacturers requirements and as required by NEPA and local code authorities.. 3.3 SCHEDULE A. Install in accordance with Drawing Symbols as follows: 1, 18"/12" L1": indicates 18" by 12" duct (metal dimension) with 1 inch soundlining; 12 indicates 2 inch soundlining, etc. 2, 18"112" W'; indicates 18" by 12" duct (metal dimension) with 1-1/2 inches external insulation wrap. 3. 18"/12": indicates 18" by 12" duct (metal dimension) with no soundlining or external insulation wrap END OF SECTION 230713-2 08125/13 UPPER ROOF UL LISTED THERMAL CERAMIC FIREMASTER FIREWRAP INSULATION - TWO LAYERS FOR ZERO CLEARANCE TO COMBUSTIBLES 3RD FLR UPPER LEVEL STOCK TERMINATE 12" - ABOVE ADJACENT ROOF SURFACE WALL PENETRATION --- SEE SEE DETAIL 1 ON RM3.2 DUCT SUPPORT DUCT SUPPORT AS REQUIRED SLOPE TO FAN INLET DISCHARGE DUCT - SEE PLANS FOR SIZE TRANSITION AS REQUIRED BOLTED FLANGED DISCHARGE CONNECTION EF -2o SEE EQUIPMENT SCHEDULE BOLTED ACCESS DOOR NON-COMBUSTIBLE CURB BY OTHERS (SEE ARCH.) 3RD FLR ROOF TRANSITION FLAT ON BOTTOM TO FAN INLET SIZE '� ELEVATION �J SCALE: NTS NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 233000 HVAC AIR DISTRIBUTION PART 1- GENERAL 1.1 SUMMARY A. Section includes: System of sheet metal ductwork, grille collars, intake housings, connections, exhaust and other fans, required to supply, recirculate and exhaust building air. B. Related Sections: 1, 230013 - Mechanical General Provisions. 2. 230713 - Duct Insulation. 3. 230900 - Instrumentation and Control for HVAC. 4. 237000 - Central HVAC Equipment. 5, 255500 - Integrated Automation Control of HVAC. 6. 260013 - Electrical General Provisions, C. Drawings, the provisions of the Agreement, including bonds and certificates, the General Conditions, and Division 01 specification sections apply to all work of this Section. 1.2 SUBMITTALS A. Make submittals in accordance with Section 013300 and Section 230013, B. Product Data: Submit complete product literature for each system and component. Include a list of all equipment to be provided, showing ratings for equipment where appropriate. 1.3 QUALITY ASSURANCE A. Comply with all pertinent codes and regulations, recommendations of the Sheet Metal and Air Conditioning Contractors National Association, Inc., (SMACNA) as they apply to work in this Section. B. Fabricator/Installer PSF Mechanical (206/764-9663). 1.4 SUBCONTRACTOR GUARANTY A. Furnish Subcontractor Guaranties in accordance with Section 017700. PART 2 - PRODUCTS 2.1 SHEET METAL A. Fabricate all sheet metal work of galvanized iron in accordance with the latest SMACNA HVAC Duct Construction Standards, unless heavier gages are required by Code, or by special conditions; 1. Exposed round duct shall be spiral duct. 2., Medium pressure duct shall be spiral, flat oval 3. Exhaust ductwork from Type I grease hoods to be 18 gauge galvanized steel with butt -welded joints, liquid tight. 4. Exhaust ductwork from Type I1 dishwasher hoods to be aluminum. B. Duct Fabrication; 1. Construct and design in accordance with the latest edition of the ASHRAE Guide and SMACNA Standards, 2, Seal all joints end seams of ductworrk air tight with Scotch brand pressure sensitive tape or duct sealer. 3. Crimp or bead fiat duct surfaces diagonally regardless of size. 4. Make duct transitions with a slope of not more than 30" with the air stream. 5, Turning Vanes: Make turns with a throat radius of not less than the duct width, with maximum 24" radius up to 70" wide duct, or use turning vanes, Tuttle & Bailey "Ductums". 6. Waterproof all seams and joints of lined ductwork, plenums, etc., exposed to weather with mastic. 7. Round sheet metal ductwork and round flexible ductwork may be used where space and codes allow or as shown on the Drawings.. 233000-1 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 233000 - HVAC AiR DISTRIBUTION Where access doors are indicated or required, fabricate or provide of two gages heavier than plenum or duct of same size, provide doors with hinges and catches. Manufactured ductwork of lighter than code gage shall be approved by the local authority prior to installation. 22 FILTERS A. Furnish air filters of the model, size and type as required for project for all air conditioning units. B. Disposable Fiberglass Type: American Air Filter or equal C. Prior to equipment start up and air balancing, replace all filters. After final acceptance of project, and prior to store opening, replace filters in all air conditioning units. Refer to Section 230013 for balancing requirements. 22 AIR OUTLETS/INLETS A. Approved Manufacturers: Titus, Shoemaker. B. Furnish all air outlets and volume control required to effect a uniform air distribution. C. Refer to Grille/Register/Diffuser Schedule on Drawings for types. D., Birdsc°reen: 1/2 -inch mesh galvanized hardware cloth; 19 gage wire. PART 3 - EXECUTION 11 HORIZONTAL DUCT SUPPORTS A. Provide supports in accordance with the Max Max One Other Minimum Side Side Su .rt Material 12" 18" 1" x 22 gage strap 23* 35" 1" x 18 gage strap 38" 72" 3/8" rods with 2" x 2" x 1/8" trapeze 36" 98"" 3/8" rods with 2-1/2" .x 2-112" x 3/18" trapeze 3.2 VERTICAL DUCT SUPPORTS - FROM following: Maximum Support Distance Every 10 feet Every 10 feet Every 10 feet Every 10 feet FLOOR A. Provide supports in accordance with the following: Maximum Size of Rectangular Duct Angle iron Size 48" x 96" x3"x3/18" ▪ Locate all duct supports at 12 feet o,c, maximum, DUCT INSTALLATION A. Conceal all ductwork In calling spaces and chases, unless Indicated otherwise, Where ceilings and chases are not provided, install neat and square, maintaining maximum clearances above floor. B. Coordinate duct location with the work of other Sections, Ductwork shall take precedence over ail piping and electrical conduit. Structural elements, and building components exposed to view, such as lighting, shall take precedence over ductwork, C. Locate ductwork as Indicated. Where obstructions exist, use the most direct route possible; record duct locations on as -built drawings. 233000-2 08125/13 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 233000 - HVAC AIR DISTRIBUTION D. E. 3.4 A. B. C. 3.5 A. Install all ductwork with due regard for the structural Integrity of all adjacent work. Provide a minimum of 12 -inch clearance between bottom of ductwork, and equipment, and top of acoustical ceiling tiles. MISCELLANEOUS INSTALLATION REQUIREMENTS Prior to air balancing, replace all filters. After final acceptance of project, and prior to store opening, replace filters In ell air conditioning units. Refer to Section 230013 for balancing requirements. Install air outlets and volume control required to effect uniform air distribution. Actuators controlled by EMCS are to be provided under Section 255500. SCREENS Install bird screen over all outside air inlets, exhaust or relief air outlets, and exhaust fan outlets. END OF SECTION 233000-3 06125/13 3-13Z REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER PSFMechanicaI= 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 EXPIRES 12/05/ STAMP FtP/rr- (o.2c0. (I, KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 =1'-0" TR MK HVAC DETAILS AND SPECIFICATIONS RM3.1 Sheet: 4 of 5 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 237000 - CENTRAL HVAC EQUIPMENT PART 1- GENERAL 1.1 SUMMARY A. Section includes: Air conditioning, heating and ventilation systems. B. Related Sections: 1. 061000 - Rough Carpentry: Wood curbs, pads, and bases for roof -mounted equipment, except where factory curbs are furnished. 2. 078200 - Sheet Metal Mashing and Trim: Mashing of equipment curbs or openings where ducts pass through roof, walls, or floors. 3.. 083100- Access Doors and Panels. 4. 098800 - Carpeting: Scheduling requirements. 6. 230013 - Mechanical General Provisions: Rooftop Unit inspection Reports. 6. 230900 - instrumentation and Control for HVAC. 7. 255500 - instrumentation and Control for HVAC, 8. Division 20 - Electrical: Ail line voltage and low voltage wiring required for HVAC equipment including conduit, wire, magnetic starters, and disconns. C. Drawings, the provisions of the Agreement, including bonds and certificates, the General Conditions, and Division 01 specification sections apply to all work of this Section,. 1.2 SYSTEM DESCRIPTION A. Complete system includes, but is not limited to: 1. Packaged air conditioning equipment. 2. Air handling systems with required fans, filters, moils, 3. Exhaust systems and miscellaneous appurtenances.. 1.3 SUBMITTALS A. Make ,submittals in accordance with Section 013300 and 230013. S. Product Date: Submit complete product literature for each product or system. C. Shop Drawings: Submit shop drawings. D. Quality Contrdl Submittals: 1.. Submit equipment lists. E. Contract Closeout Submittals: 1. Conform to Section 017700. 2. Record drawings. 3. Operation and maintenance manuals. 4. Balancing log. ;5. Start-up sheets. 1.A QUALITY ASSURANCE A, Standards: 1. All material and workmanship shall comply with applicable local, county, state and national standards. 2. Noise levels in the occupied spaces resulting from equipment and air noise on Sales Floor and Stock Rooms shall not exceed NC45, office areas and dressing rooms shall not exceed NC -35. B. Codes: Comply with requirements of Jurisdictional Code authorities, C. Safety: Comply with all rules and regulations of this State's industrial Accident Commission and NFPA 101. D. Installer: P8F Mechanical (2061764.9663). E. Pre -installation Conference: Attend roofing pre -installation conference specified in Section 075113. 237000-1 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA,WAS`HINGTON SECTION 237000 CENTRAL HVAC EQUIPMENT 1.5 COORDINATION A. EMCS Wiring: Coordinate with Section 230900 and 255500 in planning the layout of the control wiring. 1.8 WARRANTY A. Submit in accordance with Section 017700. B. Warrant equipment, material and workmanship to be free of defects for a period of one year after acceptance of Job, contingent on proper use and maintenance. Replace all parts proved to be defective during that time period at no additional cost to the Owner. 1.7 SUBCONTRACTOR GUARANTY A. Furnish Subcontractor Guaranties in accordance with Section 017700, 1.8 EQUIPMENT IDENTIFICATION A. Stencil or label all mechanicalequipment with identtflcatton mark shown on equipment schedules: 1.9 BENEFICIAL USE A. Date of start-up and operation of permanent systems shall be approved by the Owner and Architect; refer to Section 015000 - Temporary Facilities and Controls. B. Except where more restrictive limits are necessary For Installation of finishes, utilize building heating equipment only as neoesssary to maintain air temperature not to exceed 65°F; utilize cooling equipment only as necessary to maintain air temperature no lower than t80'F. C.. Coordinate with Section 255500 for temporary operation of HVAC systems prior to project turnover. PART 2 - PRODUCTS 2.1 AIR CONDIT1ONiNG AND HEATING UNflS - GENERAL A. Manufacturer: Trane Company, unless otherwise scheduled on the Drawings. B. Type,: Completely pre -assembled units, including supply fans and return fans, compressors, coils (DX) condenser section, pre -wired, piped and charged: models sizes and types as scheduled on the Drawings. Units shall be U.L. listed. C. Provide for low -ambient operation as required. D. Variable Frequency Drives: Provide as Indicated on equipment schedule, E. High Efficiency Motors: Provide high efficiency supply and exhaust fan motors in lieu of standard motors where available as a standard fairy option. 2.2 PACKAGED SPLIT SYSTEM UNiTS A. Manufacturer: Mitsubishi, unless otherwise scheduled on the Drawings B. Components: 1, Air cooled condensing units on roof and fan coil units in space with interconnecting refrigerant piping and wiring. 2, The air cooled condensing units consist of compressor, coil, controls and piping. 3.. Ship units with 1" throwaway fiberglass construction filters; provide American Air Filter, or equal, liters for installation at end of construction. See Section 230013 for balancing requirements. 4. Refrigerant piping; a. Tubing: Refrigerant grade "L" or type "K" hard drawn, degreased, sealed -at -the -mill copper tubing. If for any reason, sealed tubing is not available, non -sealed tubing of the same type may be used if Architect is so advised and If the tubing is cleaned as described in this section. b. Fittings: Wrought copper. c. Expansion Valves: Sporiand or Alco, provide one (1) for each step. 237000-2 06/25/13 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 237000 - CENTRAL HVAC EQUIPMENT d. Solenoid Valves: Sporiand or Alco; provide one (1) for each step, a. Dehyd rator and Moisture indicator: Sporiand "Catthail" or Mueller "Drymaster". f. Suction Trap or Accumulator: ASME Code construction, stamped, and registered; any commercially available separator of adequate dimension acceptable. Liquid suction heat exchangers of the "Clean -Up" type, Check valves located in by-pass liquid lines must be special non -chattering type, such as manufactured by Henry ValveCompany. Furnish refrigerant distributors for the indoor coils with side connections in line between distributor and expansion valve for centrifugal or venturi flow type of distribution. Submit shopdrawings of refrigerant piping, compatible with equipment proposed, before starting any work. 2.3 EXHAUST FANS AND TRANSFER FANS A. Cook, Greenheck, or equal. B. General Requirements: 1. Units shall be UL listed for Intended application, wired In accordance with the NEC. 2. All fans shall be ANCA certified., and all fan wheels shall be dynamically balanced. 3, Provide with backdraft damper and birdscreen as indicated on drawings. 4. High Efficiency Motors: Provide high efficiency motors in lieu of standard motors where available as a standard factory option. 2.4 GREASE EXHAUST HOODS A. KEES Model AKA, or equal. B. General Requirements: 1.. Units shall be commercial quality canopy type kitchen hoods, single sthell, for exhaust only (make-up air not supplied directly to hood). 2, Hoods shall be UL classified and meet NSF and NFPA 98 requirements. 3.. Hoods and exhaust ductwork shall be constructed of 18 gage Type 304 stainless steel (exposed surfaces) and 16 gage galvanized or black steel (unexposed surfaces), All seams continuously welded liquid tight. Exposed seams ground and polished to match hood surfaces. 4. Ductwork exposed on roof to be 18 gage galvanized steel or 18 gage stainless steel. 5. Provide vapor proof UL listed incandescent light fixtures provided to junction box at top of hood. Wiring shall conform to the NEC. 8. Provide enclosure panel above hood where applicable:, 7. Provide wvith grease filter. 2.5 GREASE FILTER A, Manufacturer: Research Products, Flame Guard, inc., or equal:, B, General Requirements: 1. Filter shall consist of an outside rear and front frame of nickel plated steel welded to a front face of expanded steel; two opposing Teflon -coated baffles inside, separated by four springs surrounding adjustment bolts holding unit together and acting as an adjustment for the baffles, to regulate air flow. 2. Filters shall be minimum 94 percent efficient at grease extraction. 3. Filters shall be UL classified and meet current NFPA 98 requirements h. j. PART 3 - EXECUTION 3.1 INSTALLATION PACKAGED UNITS A. Furnish necessary equipment block-outs, construction drawings, curbs, and the like, to roofing Section prior to roofing. B. Install A.C. Units and Heaters per details on drawings and in accordance With manufacturer's recommendations. 237000-3 NORDSTROM - SOUTHCENTER (005) CAFE REMODEL TUKWILA, WASHINGTON SECTION 237000 - CENTRAL HVAC EQUIPMENT C. Install air conditioning units on factory curb or sleepers, as required. Factory curb to sit on leveling curb provided under other sections. Coordinate unit locations end Installation details with Architect and General Contractor., D. Coordinate design and Installation of heating and ventilating and air conditioning system with other trades. E. Startup: Unit manufacturer shall be responsible for initial startup and checkout of ail components. Cycle units through all stages to assure proper operation of equipment. Check all controls for proper calibration. Start-up services shall be provided by the Trans Company. Provide detailed start-up report. 3.2 INSTALLATION OF REFRIGERATION PiPING A. Layout refrigerant piping system in manner to prevent liquid refrigerant from entering the compressor and so that oil will return to the compressor. Slope all horizontal euction lines toward the compressor. B. In suction line, provide a low micron suction fitter near the compressor. if the pressure drop exceeds 2 psi across the filter after 24 hours operation, replace filter. Test for leaks, evacuate, and recharge system. In liquid line, provide a low micron liquid filter dryer. C. Take special care to keep all tubing clean and dry. Use only sealed -at -the -mill (ACR) copper tubing. D. Install all refrigerant piping straight and free from kinks and restrictions, properly supported to minimize vibration. Provide straps or hangers at 8' spacing for 1./2" lines, 6' spacing for 1" lines and 5' spacing for 1-1/2" and larger lines. E. Make all copper -to -copper and copper -to -brass brazed joints with 15% sllver/phosicopper brazing alloy. Use a suitable brazing flux for brazing copper to brass. Pass a slow stream of dry nitrogen through the tubing at all times while brazing to eliminate the formation of copper oxide Inside the tubing. 3.3 'TESTING OF REFRIGERATION PIPING A. Testing: 1. When the refrigerant connections have been completed, the compressor suction and discharge valve (or receiver outlet valve In the case of a condensing unit) shall be closed and the balance of the system shall be tested to 150 psi pressure (or higher as required by code) with all other valves wide open. 2. Accomplish the pressure test by adding refrigerant to 10 psi and nitrogen to bring the pressure up to the required amount, 3. Carefully test all joints, using soap bubble method or an electronic leak detector. if leaks are found, mark the spot. 4. After all Joints are tested, discharge the gas, repair ail leaks, then repeat the test. 5, When testing has been completed, reduce the pressure in the system to atmospheric pressure. B. Evacuating: 1. Evacuate the refrigerant system at least two times, using a two-stage vacuum pump capable of pulling to 100 microns or better on itself, and as manufactured by J/B industries, Robinair. Do not, under any circumstances, use the system compressor to evacuate the system. 2.. Connect the vacuum pump to the system through 5/8" 0,D, or larger line connected to a flange adapter installed between the suction service valve and the compressor suction ports. Connect a second line to the charging valve in the liquid line to allow evacuation from both high and low sided simultaneously. This second line shall be the same size as the liquid line. During evacuation, do not operate hermetic or semi -hermetic motors because of the danger of insulation breakdown in verydeep vacuum. To safeguard against this, pull the disconnect switch and remove the fuses, or make sure that the circuit breaker is in the "off" position. 237000-4 06/25/13 NORDSTROM - SOUTHCENTER (003) CAFE REMODEL 'TUKWILA, WASHINGTON SECTION 237000 - CENTRAL HVAC EQUIPMENT Evacuate each system 3 times to 500 microns or less ('(1/2 mm of mercury) absolute pressure. Measure the vacuum with an electronic vacuum gauge or other suitable vacuum indicator which can be read accurately below 500 microns. Prove the first vacuum by holding It at least one hour with no increase in pressure (taking all changes in ambient temperature into account) to above 500 microns. C, Charging: 1, After the third evacuation, add the proper amount of refrigerant, check the oil level In the compressor, and add or remove oil as necessary to bring the level In the compressor to the middle of the sight glass. 2. Use only oil recommended by the manufacturer of the compressor and delivered to the job site in sealed containers with all labels Intact and legible at the time of use. 3. Charge all refrigerant into the system through a drier and using only, a refrigerant delivered to the job site In factory -charged cylinder. 4.. Do not start motors until lubrication has been checked and the proper oil and/or grease has been added where required. 3A START, "TEST AND ADJUST A. Start and test each piece of equipment to manufacturer's specification for proper functioning of all controls, During final inspection by Engineer, provide service man to demonstrate equipment. B. Air balancing is specified under Section 230013. C, Inspect rooftop units and prepare Inspection Report for submittal under Section 017700. D. Prevent short (rapid) cycling of HVAC equipment during special testing for smoke evacuation, etc. 3.5 INSTRUCTION OF OWNER'S PERSONNEL A. At completion of checkout and when all systems are operational, the unit manufacturer's qualified technician man shall schedule a 2 -hour insstruciion period for the Owner's personnel toacquaint them with the unit operation. Run all units through all cycles to demonstrate equipment operation and proper control sequence. END OF SECTION 237000-5 013/25/13 VU3 32 5/8" GYPSUM BOARD (INTERIOR SIDE) 3M ARE BARRIER 1000 NS OR 2000+ SILICONE SEALANT BANDING OR PINNING 6" METAL STUD WALL 1" CEMENT PLASTER OVER METAL LATH (EXTERIOR SIDE) WALL PENETRATION WEATHERPROOF SHIELD BY OTHERS - SEE ARCHITECTURAL III r r r PACKING MATERIAL I� DUCT (SEE PLANS FOR SIZING) FIREMASTER FIREWRAP INSULATION I1 3" MINIMUM OR PER CODE STAINLESS STEEL DUCT DOWN TO EXHAUST FAN ON ROOF y REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 4 2013 City of Tukwila BUILDING DIVISION GREASE DUCT EXTERIOR WALL PENETRATION RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER (IF PSFMechanical 9322 14th Avenue South Seattle, WA 98108-5102 p: 206.764.9663 I EXPIRES 12/05/ zoitt STAMP �1v f rr (p.210.1� KEYPLAN Revisions Date Proj No: Scale: Drawn By: Checked By: 40954 1'-0" =1'-0" TR MK HVAC SPECIFICATIONS RM3.2 Sheet: 5 of 5