Loading...
HomeMy WebLinkAboutPermit M13-133 - MONEY TREE - INSTALL HEAT PUMPMONEYTREE 6820 FORT DENT WY M13-133 City of tukwila r Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Project Name: MONEY TREE Permit Number: M13-133 Issue Date: 08/26/2013 Permit Expires On: 02/22/2014 Owner: Name: JOHN C RADOVICH LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA 98040 Contact Person: Name: PAUL JOSEPH Address: 4426 221 PL NE , REDMOND WA 98053 Email: PCLIMATE@AOL.COM Contractor: Name: PERFECT CLIMATE INC Address: 4426 221 PL NE , REDMOND WA 98053 Contractor License No: PERFECI022D5 Phone: 425 260-6955 Phone: 206-977-7353 Expiration Date: 03/12/2014 DESCRIPTION OF WORK: INSTALL 1.5 TON HEAT PUMP SPLIT SYSTEM AND DUCTWORK Value of Mechanical: $9,500.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $311.81 International Mechanical Code Edition: 2012 Date: a 12-L4(3 I hereby certify that I have read and : xami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, whether specified herein or not. The granting of this permit does not pre . e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: V 4— )b Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. RA4', 1')'7 �� „tea• nu_la_)ni • PERMIT CONDITIONS Permit No. M13-133 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-133 Printed: 08-26-2013 CITY OF TUKWI Community DevelopmetWepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Pet No Project No -Date Application Accepted: MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** r SITE LOCATION Site Address: 67x0 Fo c -T Dom- Loy Tenant Name: Moroi TRc� PROPERTY OWNER Name: Name: �C- 2P1000\c\► City: State: Zip: City: j2C Pfll0t^n lea- TboS 3 Address: 20 ) ja 4 *-1- Ave. iu b 103 City: State: )C l r _ L),11- Zip: 9 b a0C CONTACT PERSON .,person receiving all project{ communication Name: Address: tiu ZG 22' S' 9t 6) e -- City: State: Zip: City: j2C Pfll0t^n lea- TboS 3 Phone: Fax: ciZ5--240-69 Email: 7r' L. me," -E re) 6"oL , Gum King Co Assessor's Tax No.: 2Cj St/ 9 0- a (/CS Suite Number: Floor: New Tenant: ❑ Yes 147atio ' MECHANICAL CONTRACTOR INFORMATION Company Name:!- j'C‘2-c--►�C-1 C L vv‘.A SE' a NZ. Address: c.1zG 2_2_i S; , we - City: State: `41� Zip: £:)t7S3 Phone: Fax: kZC-26v-tis S -S Contr Reg No • Exp Date: PE e_ Tozz9S 3%12_)1 y Tukwila Business License No.: gvS0q 4 -c39 l Valuation of project (contractor's bid price): $ 50 UJ Describe the scope of work in detail: / S T10 -i l , s Ta f- -errr s B L.A. V 5 y s; e -on Use: Residential: Commercial: New New Replacement Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechamcal Permit Application Revised 8-9.11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type. Qty Furnace <100k btu Furnace >100k btu 3 Floor furnace 1 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty: Air handling unit >10,000 cfm 3 Evaporator cooler 1 Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type . Qt6 Fire damper Diffuser 3 Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment 'Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 9 1NER O AUTHORIZED AGENT: Signature: V,/ /l^' Print Name: PiI 3 a5r- Mailing Address: 1,(1/24 ZZ i S p L IU H:\Applications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8.9-I l.docx Revised: August 2011 bh Date: 7 .— J 6 - 13 Day Telephone: t/2c'- 6 S 3-3' my CityState btA 3 Zip Page 2 of 2 r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Applicant: MONEY TREE RECEIPT Permit Number: M13-133 Status: PENDING Applied Date: 07/16/2013 Issue Date: Receipt No.: R13-02149 Payment Amount: $311.81 Initials: JEM Payment Date: 07/16/2013 01:43 PM User ID: 1165 Balance: $0.00 Payee: PERFECT CLIMATE INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 9970 311.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 249.45 000.345.830 62.36 Total: $311.81 Printed: 07-16-2013 INSPECTION NO. INSPECTION RECORD Retain a copy with permit �.1 i3 -1.33 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj ct:Type f Inspect`on: , 1---.` AL- Addres1 CO r I;e ( Dat �a�lfed: -P c i \- c . !�` ,7,,:- Special Instructions: Date Wan ed: , 6j ''i - ( - �a.m p.m. Requester: Phone No: ( ,.- - Approved per applicable codes. Correctiors required prior to approval. 7 COMMENTS: k w (:� -P c i \- c . !�` , 1% ____-------___-- , - 1• Inspector: n REINSPECTION FEE REQUIRED. Prior to nextinsection.,fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to scheule"reinspection. Date �, -(q (3 INSPECTION RECORD Retain a copy vvith permit INSPECT!, N NO. Mt3-/33 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 ► . Project:.._• MO A. 2. I f'C f Typy of Inspection:__ P -)u Ca H e--021 Address� `— L0711,6 Ft 6P4- Date Called: ,.-.. Special Instructions: Date Wanted: �/ 1 m. r -'?,v - /3 em. Requester: Phone No: *e=i'LS -530-32(p'.. DApproved per applicable codes. E 1 Corrections required prior to approval. l� COMMENTS: aik__:__ / `--0 U , H-' € 'i 7)±:2-- �--- • {F _e c c ,r? -Tri-- RAI ? -/- •-- ibtA /1- Ve Ai -3 i 7-4.jp•e- U4 .~ J/k �j r ;K) 1 -1 -h -ie. yug7— ;As 9(.6--Te4 re_Crl Ii Ins ector: L Date B n REINSPECTION FEE EQUIRED. Prior dnext inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.- 1.5T SS HP 15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM FILE COPY Permit No. --- 1.5T SS HP -15.3 Seer Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OE TUKWILA JUL 1 6 2013 PERMIT CENTER M13 - Residential Carrier Products Bldr 1.19k Page 1 of 9 Unit Report For 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM Outdoor Unit Parameters Unit Quantity. 1 Indoor Unit Parameters Unit Quantity. 1 Unit Model: ........ 25HCC Unit Moder FX4D Unit Size. 1.5 Tons Unit Size. 18,000 Btuh Voltage 2081230-1 V -Ph -Hz Cabinet Insulation:Single-piece cabinet with 1 -in. super thick insulation Voltage. 208/230-1-60 V -Ph -Hz System Parameter System Quantity. 1 Heating Size. No Heat Outdoor Unit Dimensions and Weight Indoor Unit Dimensions and Weight Unit Length. 2' 8.0" Unit Length: 1' 10.1" Unit Width 3' Unit Width 1' 6.0" Unit Height 2' 8.0" Unit Height 4' 2.0" Unit Shipping Weight 207 Ib Unit Shipping Weight 122 Ib Note:Outdoor unit dimensions may vary depending on the minor series sent from the factory. Warranty Information Indoor FX4D First Year - Parts Only (Standard) Warranty Information Outdoor 25HCC First Year - Parts Only (Standard) Ordering Information Part Number Description Quantity Outdoor Unit 25HCC518A003 25HCC Comfort Series Heat Pump with Puron Refrigerant 1.5 Tons Cooling 1 . Base Unit 15 SEER @ ARI Conditions 1 Standard 1 Accessories KAACH1701AAA Crankcase Heater 1 KAAFT0101AAA Evaporator Freeze Thermostat 1 Base Unit - Indoor FX4DNF019000 FX4D Comfort Series Fan Coil with Puron 18000 BTU Cooling 1 Base Unit Single -piece cabinet with 1 -in. super thick insulation 1 Standard 1 Residential Carrier Products Bldr 1.19k Page 2 of 9 Unit Report For 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM Accessories KFCEH2401C05 5 kW Electric Heater with Circuit Breaker 1 Residential Carrier Products Bldr 1.19k Page 3 of 9 Performance Summary For 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM System: 25HCC/FX4D System Quantity* 1 Altitude. 0.0 ft Linear Pipe Length' 0.0 ft Actual SEER. 15.3 EER @ ARI Conditions. 12.6 Outdoor Unit Parameters Unit Quantity' 1 Unit Model. 25HCC518A003 Unit Size (Nominal). 1.5 Tons Voltage' 208/230-1 V -Ph -Hz Clg Ent Air DB Ambient' 95.0 °F Htg Ent Air DB Ambient' 47.0 °F Heat Pump Htg HP Capacity' 18.00 MBH Htg HP Integrated Capacity. 18.00 MBH Heating HP Compressor Power 1.35 kW Htg Ent Air DB' 70.0 °F Htg Lvg Air DB' 97.8 °F HSPF. 8.6 Indoor Electrical Data: (For units with no factory installed electric heaters) Unit Voltage' 208/230-1-60 V -Ph -Hz Unit FLA' 2.8 Amps Unit MCA' 3.5 Amps Unit MOCP. 15.0 Amps Unit Min Wire Size' 14.0 113 HP Motor HP. :Notice: Indoor Elect data is for 2081230-1-60 voltage Acoustics Sound Power Levels, db re 10E-12 Watts Indoor Unit Parameters Unit Quantity' 1 Unit Model' FX4DNF019000 Unit Size (Nominal)' 18,000 Btuh Voltage' 208/230-1-60 V -Ph -Hz Actual Airflow: 600.0 CFM Standard Airflow' 600.0 CFM Total Net Clg Capacity. 17.80 MBH Net Sensible Clg Capacity' 13.60 MBH Ent Air DB' 80.00 °F Ent Air WB' 67.00 °F Ent Enthalpy 31.44 BTU/Ib Lvg Air DB' 59.01 °F Lvg Air WB: 57.71 °F Lvg Enthalpy' 24.85 BTU/Ib Heating Size (Nominal). No Heat Indoor Unit External Static' 0.50 in wg Total System Power 1.42 kW Outdoor Electrical Data Unit Voltage: 208/230-1 V -Ph -Hz Fan Motor FLA. 0.50 Amps MCA: 13.1 Amps Max Fuse' 20 Amps Operating Range Min' 197 V Operating Range Max' 253 V Compressor RLA. 10.1 Amps Compressor LRA' 48.0 Amps Min Wire Size @ 60C. 14 Min Wire Size @ 75C. 14 Max Length Wire Size @ 60C. 60 ft Max Length Wire Size @ 75C. 57 ft Accessory Electric Heater Data (Single point power for unit WITH electric heaters) EH Part Number KFCEH2401C05 Electric Heater kW 5.0 kW :For 2 wire operation (single circuit). Heater Amps' 18.1/20.0 Amps Heater + Motor MCA. _ 26.0/28.4 Amps Heater + Motor MOCP. 30/30 Amps :For 4 wire operation (dual circuit). Accessory Voltage- 208/230-1-60 V -Ph -Hz Residential Carrier Products Bldr 1.19k Page 4 of 9 Outdoor Unit (dB) Indoor Unit (da DBA Level 75.0 NA 63Hz NA 64.7 125Hz 54.0 60.7 250Hz 63.0 56.7 500Hz 68.5 53.7 Residential Carrier Products Bldr 1.19k Page 4 of 9 Performance Summary For 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent 07/08/2013 Prepared By: 03:20PM 1000Hz 71.5 51.7 2000Hz 68.0 49.7 4000Hz 63.5 45.7 8000Hz 57.0 NA Sound Message Residential Carrier Products Bldr 1.19k Page 5 of 9 Acoustic Summary For 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM Outdoor Unit Parameters: Tag Name. Unit Model• 1.5T SS HP -15.3 Seer 25HCC Unit Size' 1.5 Tons Variations' Standard Octave Band Center Frequency, Hz 63 125 250 500 1 k 2k 4k 8k dBA Sound Power,dB 0.0 54.0 63.0 68.5 71.5 68.0 63.5 57.0 A -Weighted Sound Power, dBA 75.0 Indoor Unit Parameters: Tag Name. Unit Model' .............. Unit Size: Cabinet Insulation. 1.5T SS HP -15.3 Seer FX4D 18,000 Btuh Single -piece cabinet with 1 -in. super thick insulation Octave Band Center Frequency, Hz 6:3 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 64.7 60.7 56.7 53.7 51.7 49.7 45.7 0.0 A -Weighted Sound Power, dBA 0.0 Residential Carrier Products Bldr 1.19k Page 6 of 9 Residential Carrier Products Bldr 1.19k CD m CD CD 0 CO DIMENSIONS - ENGLISH UNIT SERIES ELECTRICAL CHARACTERISTICS A B C D E 31 1/2' X 31 I/2' F 0 K L M N p OPERATING WEIGHT. (bsl SHIPPING WEIGHT abs) SHIPPING DIMENSIONS (L x W x HI 25HCC518 0 k 0 0 0 31 3/16' 28 15/16' 3 3/4' 5/8' 6 9/16' 24 11/I6' 9 1/6' 2 13/16' 1/2' 76' 15' 14' 169 201 32 5/16' k 35 1/2' k 32 9/I6' 75HCC524 0 X 0 0 0 35' 32 5/16' 3 3/4' 5/8' 6 9/16' 28 7116' 9 1/8' 2 13/16' 1/2' 15 3/4" 16 3/4' 16 1/2' 200 233 36 1/8' X 39 1/4' A 35 15/16' 25HCC530 0 X 0 0 0 35' 32 5/16' 3 3/4' 3/4' 6 9/16' 28 7/16' 9 I/O" 7 13/16' 1/2' 16 7/4" 16' 15 1/2' 196 242 36 1/8' X 39 7/4' X 35 15/16' 25HCC536 0 k 0 0 0 35' 35 314' 3 3/4' 3/4' 6 9/16' 28 7/16' 9 I/O' 7 13/16' 1/2' 15 3/4" 16 3/4' II' 215 257 36 1/8' X 39 1/4' k 39 3/8' 25HCC542 0 X 0 0 0 35' 28 15/16' 3 7/8' 1/8' 6 9/16' 28 7/16' 9 1/8' 7 15/16' 5/8" 17' 16 3/4' 14 3/4' 245 290 36 I/8' X 39 1/4' X 32 9/16' 25HCC548 0 X 0 0 0 35' 28 15/16' 3 1/8' NB' 6 9/16' 28 7/16' 9 1/8' 2 15/16' 5/8' 76 3/4" 16 1/4' 14' 260 303 36 1/8' 6 39 174' X 32 9/16' 25HCC560 0 X 0 0 0 35' 39 1/8' 3 7/6' 7/8' 6 9/16' 28 7/16' 9 1/8' 2 15/16' 5/8' 17 1/4" 16 714' 18 1/4' 294 345 36 1/8' X 39 1/4' 5 42 3/4' th X r 1E5 0/ NO A S0. AIR DISCHARGE f / B FIELD CONTROL SUPPLY CONN. 07/e. HOLE FIELD POWER SUPPLY CONN. 0 7/8' MOLE NUR 01 I/8' KNOCKOUT 0)/8" 1/OU/D LINE CONN. C 3 1/2' 11111111111111 111111 111111111 11111111111 III II III I II 00 VAPOR LINE CONN. AIR I1r+ 3 13/16' NOTES: 1, ALLOW 30' CLEARANCE 10 SERVICE SIDE OF UNIT, 48' ABOVE UNIT, 6' ON ONE SIDE. 12. ON REMAINING SIDE. AND 24' BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 551, MAX. 125°F. 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4, CENTER OF GRAVITY ®. 5. ALL DIMENSIONS ARE IN "INCHES' UNLESS NOTED. IR IN AIR xxaxiAksx F L-1 1 1/B'+ 03/8" TIEDOWN KNOCKOUTS 12/ PLACES AIR IN 25HCC5 IR IN 13 "0 (n o. co a) CD CL CO c) —1 (D T O v (D MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 26' X 26' 18 31 1/2' X 31 I/2' 24,30,36.42.48,60 35' X 35" AIR I1r+ 3 13/16' NOTES: 1, ALLOW 30' CLEARANCE 10 SERVICE SIDE OF UNIT, 48' ABOVE UNIT, 6' ON ONE SIDE. 12. ON REMAINING SIDE. AND 24' BETWEEN UNITS FOR PROPER AIRFLOW. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 551, MAX. 125°F. 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4, CENTER OF GRAVITY ®. 5. ALL DIMENSIONS ARE IN "INCHES' UNLESS NOTED. IR IN AIR xxaxiAksx F L-1 1 1/B'+ 03/8" TIEDOWN KNOCKOUTS 12/ PLACES AIR IN 25HCC5 IR IN 13 "0 (n o. co a) CD CL CO c) —1 (D T O v (D Certified Drawing for 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM ROCOMTES: 1. DEN0BTE PAR DRAIN CAPS 201 02022 FOR CLARITY. 2. ALL 010220/002 ARE IN 'INCHES' UNLESS NOTED. 2(2FLOW f -r 2 3/16' TYP 1 12 PLACES/. SECONDARY D2A1 PRIMARY DIA! 1' TTP. l2 PLACES,• 1116' TTP. 14 PLACES/. DOWNFLOW (Fir:D Coi: rreED) PRIMARY D2A1 SECONDARY DIAL 5116' IP.• DIVBVSIONS (cont) I GF'r COD 1 13/16' TTP. 2 /8• 2, 1v/' 22 HORIZ RIGHT (FIE:) CO:7VLR7ED) 1/8' TTP.. SECONDARY DRAT 2 3/16• TTP. l2 PLACES)• UPFLOW (AS ;ItI'PED) PRIIA82 BIAI SECONDARY DRAIr 1 13/16 TTP.. 2 1/1' 1/2' TTP . 1/8' THP. HORIZ. LEFT LAS i)AIPPED) S/16' rrr.. TP..1 1 5/8' 21/8' • 00211007AL MOUNT LOCATIONS - DIMPLES PROVIDED IM TOP PANEL, AND BACH Of 022(2(2. LN C/8IHL1 80:502. PALES PROVIDED .138' DIA. HORIZONTAL RANGING HARDWARE 10 BE FIELD SUPPLIED. AIRFLOW 2 r 1 3/lACES/*• TTP.• PL 1 1 7/6' TIP. F / 3u' '-ap { 6 3 1/16' -ry ILj ECORDARi DRAIN t '0(0281 DCA111—•''' A -00I1 PRIMARY DUI SECONDARY DRA 1 13/16' T1P• 1/2 TIP F Li; TTP. . 1 I2 PLACES)• 1/16' TIP, 11 PLACES). DOWNFLOW (FIELD CONVERTED) 1 1/2' 51/6e /1/8 HORIZ. LEFT (A.. iitI?PED) 5/ • TIP 2 112' 1 11/16' HP. HORIZ. RIGHT (FIELD CONVERTED) Fb 2 - FXI - &pi 5 SLC011A8T ORA: PRIMARY HAI AIRFION 1/16' TTP. (/ PLACES) -1' TTP. 12 PLACES) 2 3/16' TIP. 12 PLACES). 3 I/16' 43/4' UPFLOW (AS SHIPPED) 3. 1/8 2 11/16' A13 0 X LL Residential Carrier Products Bldr 1.19k Page 8 of 9 Certified Drawing for 1.5T SS HP -15.3 Seer Project: Money Tree -Fort Dent Prepared By: 07/08/2013 03:20PM O X LL 1 718' DIMENSIONS 1YT A 9 C D E F G N J E01F TOIL p SHIPPING 9T N01 TIN -COATED SHIPPING 61 TIN -COATED SLOPE 'A' F940NF919 49 5/8' 17 5/8' 15 3/4' IS 5/8' 05 3/8' 23 1/8' 23 5/8' - 17' X - 122 122 FIIDIF025 49 5/8' 1T 5/8' 15 3/4' 15 519" 15 3/8' 23 1/8' 23 5/8' - 17' I - 122 122 F31DNF031 53 7/16' 21 1/8' 19 1/4' 19 1/9' 19 3/16' 26 li/li' 21 1/2' - 19' 2 - 146 146 (11081037 49 576' 21 1/8' 19 1/4' 19 1/8' 15 11/16' 23 7/16' 23 1/8' - - - 2 157 151 FI/DNF043 49 5/8' 21 1/6' 19 1//' I9 1/8' 15 11/16' 23 7/16' 23 1/8' - - - 2 151 152 21408(019 53 7116' 24 11116' 22 3/4' 22 11/16' 19 1/2' 27 1/4' 26 15/16' - - - I 185 185 114062061 59 3/16' 21 11/16' 22 304' 22 11/16' 25 1/4' 32 15/16' 32 5/8' - - - 0 201 201 MOTE: 1. 8[11(8 1010101011 IS IRE 111/ POSITION OS 10111 210NICT MUM 2. All 01NE111011 191 IN '11)111' DILISS WED. 7/8', 1 3/3 ' 2' DIA, CO.'S FOR HIGH VO TAGE POWER Vi71NG 15/16' 25/8' B C _11177 CCI6NECT_ON SI ZES SUCTION: 018 8 024 - 5/8' I.D. SWEAT 030 6 036 - 3/4' I.D. SWEAT 042 THRU 060 - 7/8' 1.0. SWEAT LIOUID: 3/8' I.D. SWEAT CO'i9ELSAT_: 311' FPT 7/8'01A. K.O. FOR LOW VOLTAGE 0881901 WIRING 3/8' ISCONNECT OR CIRCUIT BREAKER LOCATION 10 7/16' LOWER. CONTROL, 6 ELECTRIC HEATER ACCESS PANEL OIL ACCESS PANEL IOUID LINE CONNECTION SUCTION LINE CONNECTION 6 3/16' 07/622: D IXLET AIB FILTER ACCESS PANEL FRONT VIEW SHOW WITH 'A' COIL DETAILS CONNECTION LOCATIONS FOR UPFIOW OR H0010. APPLICATIONS ALTERNATE 7/8'DI4. X.O. FOR LOW VOLTAGE CONTROL WIRING -l0 3/16' 21/8' 22 1/16' IIOrz: TLN 41102SE121"01C11"E ("1 11 WTLET AIR Y 1 3/16' 1 3/4" 7/8' #LIERIATE 7/8'.I 3/32'.2'DIA. 8.0.'1 FOR HIGH VOLTAGE POWER WIRING OPPOSITE SIDE OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING MOPE COIL UNITS ONLY/ 3//' NOTE: NODULAR UNITS WILL HAVE A 190 -PIECE CABINET - 1 1/2' 19 MAO H FOR NODULAR UNITS 1 1/4' OPENING 19 13/16 RIGHT SIDE VIEW INLET AIR -2 1/2' 1!ILEI AIR SLOPE COIL DETAILS CONNECTION LOCATIONS SHOWN FOR UPFLON OR HMI. LEFT APPLICATIONS Fg 1-FK/D - Eng h 4 ACCESS PANEL C0NF1G. FOR SLOPE COILS DONATION OR ROAR. RIGHT APPLICATIONS AND "A" COILS DOIINFLOW APPLICATIONS A10002 Residential Carrier Products Bldr 1.19k Page 9 of 9 ei s;. 4, lt‘ Perfect $Climate A 4426221st PI NE Redmond Wa 98053 office- 206-977-7353 fax- 425-836-3980 Project Name: Money Tree Permit# M13-133 Aug 5, 2013 SUBJECT: Correction Response Response #1. See sheet. M2 for specs and details of how unit is secured on rooftop Response #2. See sheet M2 for details on roof penetration sealing method Response #3. See sheet M2 stating all work to comply with 2012 mechanical and building codes CORRECTION M'3` 133 LTR# RECEIVED CITY OF TUKWILA AUG 0 6 2013 PERMIT CENTER 4426 221st Place Northeast • Redmond, Washington 98053 • (206) 977-7353 July 25, 2013 Paul Joseph Perfect Climate Inc 4426 221 PI NE Redmond, WA 98053 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Mechanical Permit Application Number M13-133 Moneytree — 5720 Fort Dent Wy Dear Mr. Joseph, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision: Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. M13-133 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: July 23, 2013 Project Name: Money Tree Permit #: M13-133 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. Provide details and specifications to show how the mechanical unit on the roof shall be secured to the roof on sleepers or mounts, sufficient to resist seismic and wind forces. 2. Show details specifying method for sealing roof penetrations. 3. All work shall comply with current 2012 building and mechanical codes and shall be specified on the plans. Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. • r PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-133 PROJECT NAME: MONEYTREE SITE ADDRESS: 5720 FORT DENT WY Original Plan Submittal Response to Incomplete Letter # DATE: 08-06-13 X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: g Bird Building Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator ie DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-08-13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-05-13 Approved ❑ Approved with Conditions Xr Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 �ERMIT CORD COPY el PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-133 DATE: 07/16/13 PROJECT NAME: MONEY TREE SITE ADDRESS: 6720 FORT IDENT WY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: B ilding Division Public Works 111 Alin 44 ---tct-i? Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 07/18/13 Incomplete El Not Applicable El Comments: Perri it Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/15/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) 14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: 14. • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: — f 3 Plan Check/Permit Number: M1 3-13 3 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Moneytree Project Address: 5720 Fort Dent Wy Contact Person: Pq,t JoSe9 1.1 Phone Number: ca -S- G C -S— Summary of Revision: DLS'1Prt LS (3,6- - r j VJ17 fin' t S SE' C' ti.Arre.� 1 s-nLut�l, f C. 9--vo 'pert) /06 3 co» l - wl %1'l r2 j1- C v pa- 6 ni fik RgCENai amornomnik AUG 06 2013 Sheet Number(s): IV Pglimilf OE "Cloud" or highlight all areas of revision including date of revision c Received at the City of Tukwila Permit Center by: A_.- Entered in Permits Plus on O, 6- \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: U Z Author. CLAIRE WIESE Mone tree Phase IIIC Site Plan Scale: NTS FILE COPY Permit No. Plan to errors and ns. min approval is ����,����� ���,. �� of construction documents does not authorize of any adopted code or ordinance. Receipt ni approved t.� s�� , I ted: By City Of Q,la BUILDING DIVISION ittleVvil ERVIC-- alleA614 ENC 3345 t .�..,,.9044.4 13,465ELEVATION 0P 2$ Y SEPARATE PERMIT REQUIRED FOR: 0 Mechanical (Electrical lumbing as Piping Ciy of Tukwila BUIWING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. DOTE: Revisions will require a new plan submittal cnd may include additional plan review fees. AUG 19 2013 City of Tukwila BUILDING DIVISION Sheet List Table Sheet Number 1-0.0 1-0.1 I—CS.1 1-1.1 I-2.1 I-3.1 1-4.1 1-5.1 1-8.1 1-9.1 1-10.1 Sheet Title Cover Sheet & Site Plan General Notes & Symbols Exit Plan And Codes Summary Demolition Plan Dimension Plan Floor Plan Demo Reflected Ceiling Plan Reflected Ceiling ?Ian Interior Elevations Construction Details Door Schedule Elevations Details (Wood) Code Information: PROJECT ADDRESS: 6720 FORT DENT WAY TUKWILA, WA 98188 CONSTRUCTION TYPE: CONST—TYPE IIA FULLY SPRINKLERED (NON QR) OCCUPANCY: B TENANT SQUARE FOOTAGE: (area of work) 2,055 SF Building Code Fire Code 2009 INTERNATIONAL BLDG CODE (IBC), WAC 51-50 2009 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B&C Energy Code 2009 WASHINGTON STATE ENERGY CODE (WSEC), WAC 51-11 2009 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51-52 JUNE 22, 2009 WA CITIES ELECTRICAL CODE, PARTS 1 & 3 AS PUBLISHED BY WA ASSOC. OF BLDG OFFICIALS 2009 UNIFORM PLUMBING CODE (UPC), WAC 51-56 & 51-57 INCL. APPENDIX CHAPTERS H & L — EXCL. SECTIONS L5—L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6-4 OF APPENDIX L Zoning Code CITY OF TUKWILA Accessibility 2003 ACCESSIBLE & USABLE BUILDINGS & Code FACILITIES (ICC/ANSI A117.1) WAC 51-50-005 Mechanical Code Electrical Code Plumbing Code Legal Description: TAX PARCEL . #295490-0455 BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE HIGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GliNDAKER'S INTERURBAN ADDITION TO SEATTLE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE LANDS CONVEYED TO KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING NO. 7507300471 AND NORTH 30'04'58" EAST 334.53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOUTH 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF TUKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08'00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 7708040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON. Vicinity Map: PROJECT SITE Project Team: Property Owner J.0 RADOVICH 2000 124TH AVE. NE., E3103 BELLEVUE, WA 98005 425-454-6060 Tenant: MON EYTREE 6720 FORT DENY WAY TUKWILA, WA 98188 206-246-3500 MEAGAN HENDERSON meagan.henderson®moneytreeinc.com Architect: CITY OF TUKWI JPC 909 ARCHITECTS, SLLC AVE NEJUL 1 6 2013 SUITE 206 BELLEVUE, WA 98004 (425) 641-9200 PERMIT CENTE MARK PETERSON — EXT. 340 markp©jpcarchitects.com CLAIRE WIESE — EXT. 351 clairew©jpca rchitects.com General Contractor: BAKER CONSTRUCTION 2711 E. SPAGUE AVENUE SPOKANE, WA 99202 509-535-3668 LIC. NO. #BAKERCD066CZ con Imanma 111 FREmm (00) zo MoneyTree Phase IIIC Floor 2 6720 Fort Dent Way Tukwila, WA 98188 A DESIGN DRAWN CHECKED NO. CCW MP 12-0803 06/17/13 PERMIT SUBMITTAL Cover Sheet & Site Plan 1-0.0 © 2012, JPC Architects, PLLC Dwg: V012 \12-0803 \DWG\WP Author: CLAIRE WIESE Pen Table: JPC STD.CTB Date/Time: 6117/2013 9: A SCOPE OF WORK Ilk OFFICE I 208 1 4i) EXEC CONF ROOM 222 1-4,6606,66,6, OFFICE 204 I OFFICE 202 OFFICE 201 BREAK ROOM 225 F.E.C. OFFICE 207 14 SHIPPINGMAILROOM/UPS CTR WORK ROOM 411 1 MIT Mill=1=11=MilF, 224 226 SERVER ROOM 228 HALLWAY 200B F.E.0 414A11 STORA 230 PANTRY IMP! OFFICE 211 OFFICE 212 It OHM OFFICE I I 219 OFFICE 213 Iif OFFICE 1 250 SCOPE OF WORK., a$ OFFICE 218 EXEC ENTRY STORAGE L232 I 232 N OFFICE 217 OFFICE 1 215 1 0 r- 'price.- to 216 0 0 3 MoneyTree Phase IIIC Floor 2 6720 Fort Dent Way Tukwila, WA 98188 IC= 4111 OTYP CONFERENCE ROOM TYP 1 220 I RECEPTION 200A Floor Plan General Notes: Floor Plan Key Notes: REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2013 City of Tukwila BUILDING DIVISION Symbols Legend: 03 I v I \ PN Floor Plan Scale: 1/8"=1 '-0" Partition Legend: 1. FLOORING TO BE CARPET (Cl) DIRECT GLUE DOWN UNLESS OTHERWISE NOTED. FOLLOW CRI GUIDELINES FOR INSTALLATION. 2. WALLS TO RECEIVE 4" HIGH RUBBER BASE RB1, THROUGHOUT UNLESS NOTED OTHERWISE. 3, WALLS TO RECEIVE P1 THROUGHOUT UNLESS NOTED OTHERWISE. 4. FOLLOW MANUFACTURER PROVIDED DETAILED INSTALLATION GUIDELINES & USING MFG. RECOMMENDED ADHESIVE PRODUCT OR TOOLS AS REQUIRED. PROVIDE TENANT WITH MANUFACTURER RECOMMENDED CARE AND MAINTENANCE INSTRUCTIONS. 5, BUILDING STANDARD DOORS THROUGHOUT UNLESS NOTED OTHERWISE. 6, SUBMIT SAMPLES TO DESIGN ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. NO WORK THIS AREA, UNLESS OTHERWISE INDICATED. POWER/COMMUNICATIONS PACKAGE (WALL) WITH (1) SINGLE GANG MUD RING (WITH PULL STRING) AND (1) 110V DUPLEX. VERIFY EACH SPECIFIC PACKAGE FOR SPECIAL REQUIREMENT DESIGNATION. D = DEDICATED CIRCUIT; IG = ISOLATED GROUND WITH FULL-SIZE NEUTRAL; DIG = DEDICATED CIRCUIT WITH ISOLATED GROUND AND FULL-SIZE NEUTRAL. ALL HORIZONTAL DATA/COMMUNICATIONS PATHWAYS IN INSULATED WALLS SHALL BE RUN IN CONDUIT OF APPROPRIATE SIZE. CONFIGURATION TO MATCH EXISTING BUILDING STANDARD. REUSE AND REINSTALL EXISTING SALVAGED ELECTRICAL AND LOW VOLTAGE SYSTEMS (CABLING, DEVICES AND EQUIPMENT) WHERE OR WHENEVER PRACTICAL (AS APPROVED BY TENANT). REFER TO GENERAL NOTES AND ELECTRICAL DESIGN -BUILD DOCUMENTS FOR ADDITIONAL INFORMATION. ANCILLARY FURNITURE FIXTURES AND EQUIPMENT. TENANT FURNISHED AND INSTALLED. INCLUDING BUT NOT LIMITED TO CHAIRS, TABLES, DESKS, AND FILE CABINETS. WHERE WALLS HAVE BEEN DEMOLISHED PATCH AND REPAIR WALL PAINT FINISH TO MATCH EXISTING ADJACENT SURFACE NEW COLUMNS. TENANT TO PROVIDE DESIGN. BUILDING STANDARD FIRE EXTINGUISHER CABINET (OR SPEC) DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE GFI DUPLEX RECEPTACLE FOURPLEX RECEPTACLE DEDICATED FOURPLEX RECEPTACLE SPECIAL RECEPTACLE CORE DRILL J -BOX FOR TENANT PROVIDED SYSTEMS FURNITURE. POWER POLE VOICE/DATA RECEPTACLE. CONTRACTOR TO PROVIDE MUD RING AND PULL STRING PROXIMITY CARD READER WALL TAG NO DESIGNATION = EXISTING N = NEW &/OR RELOCATED (COORDINATE RELOCATED ITEMS W/ARCHITECT) D = DEMOLISH EXISTING PARTITION TO BE REMOVED EXISTING PARTITION/CONSTRUCTION TO REMAIN amimmi GRID HEIGHT PARTITION. REFER TO DETAIL 3/1-9.1. RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER NOTE: AT LOCATIONS AS NECESSITATED BY POCKET DOOR SYSTEMS, "IN -WALL" ELECTRICAL AND/OR MECHANICAL SYSTEMS PROVIDE APPROPRIATE METAL STUD WIDTH TO ACCOMMODATE SIZING REQUIREMENT. CONFORM TO SPECIFIED METAL GAUGE AND SPACING AS INDICATED BY WALL TYPE. REFER TO CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. 1113--133 DESIGN ccw DRAWN CHECKED MP NO. 12-0803 06/17/13 PERMIT SUBMITTAL Floor Plan 1-3.1 © 2012, JPC Architects, PLLC va.00F. sc.mts Nr,s, ecto ?tiveligN ARA, r41).P...N4 4.135?-9,A4c- .move-4 I4C-C !I 6 Ns - , N) vItt-Nbe\-c)4t#41 ZAZCZ ao -2-10" iffte,pvz.4 vvv1,-.% 12,4 Sreg. I 5,S) ert Li‘s ThMCL 4-43-1`-t-47.2.44S)-.40Dcf-oni Coomat.0-4 k24o6y TTAA_S, 11‘.. -taokeri-fL •'" - • • • . ) • • • 44' • •)' 144—.4 • ') • 4; i , OUTDOOR AIR CALCULATOR 2012 IMC (TABLE 403.3) FOR MONEY TREE Vbz = RpPz + RaAz Room Name SF Rp (CFM/person) #/1000. sf Pz Rp x Pz Ra. Az Ra x Az Vbz (CFM) OFFICE RM. 215 456 5 5 3 15 0.06 456 27.4 42.4 42 4-, TOTAL MIN. OSA Uu3 E1) 13" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 9 2013 City of Tukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER 24 X SO CIXARPOINTO REVISIONS BY I— .Dat• 7, Scale )//ei Drawn i:75 Job Sheet Ml Of Sheets 22=4m.co. 5.1.4.1'51?)4 IN* HVAC' GENERAL NOTES 1. VERIFY site conditions. 2. THERMOSTAT LOCATIONS: Verify all wall mounted control locations with architect. 3. CODES: Comply with all local & state governing codes. 4. COORDINATE ductwork and grille locations with lighting and other related trades with architect approval. Verify clearances & ceiling elevations before installation. 5. DRAWINGS are schematic in some areas and may not show exact routing or every offset which may be required. Provide a complete & properly working system with all necessary items 6. SEISMIC BRACING: Provide to meet local code requirements. Refer to the ASHRAE standards "Practical Guide to Seismic Restraint", 1999. 7. EXHAUST FAN TERMINATION: Shall not be less than 3 feet from a property line or openings into a building, e.g., operable windows and doors. 2009 IMC, sec. 501.2.1, item #3. 8. CONDENSATE DRAINS: Run 3/4" PVC pipe from cooling coil to nearby open site drain or to outside planting bed on ground. Elevate coil to allow for proper gravity drain operation. Provide approved "P" trap at coil outlet. 2009 IMC, sec. 307. 9. SUBMITTALS: Provide equipment submittals (before ordering & installation) on all major equipment items, controls, grilles, and louvers. Submit 4 copies to architect in a single notebook with items tagged according to drawing call outs. 10. TEST, ADJUST, & BALANCE: Provide proper system testing, adjusting, and balancing on both air and water according to NEBB & ASHRAE standards, including written reports. Use only technicians qualified & trained in TAB work. Include System Commissioning: Functional testing of sequences of operation to ensure they operate in accordance with the mechanical plans (2009 WSEC, Sec 1416). Work by NEBB certified firm. 11. OPERATION & MAINTENANCE BOOKLET: Provide 0 & M manual to owner. Include cut sheets on main equipment and controls, maintenance instructions, and marked up as built drawing (record drawings per 2009 WSEC, Sec 1416). 12. WALK-THRU instruction: Provide on site walk-thru for customer to demonstrate operation of system and answer questions. 13. GUARANTEE: Contractor shall warrant the completed system from defects for one year from date of final start up. 14. ELECTRICAL: All equipment to have a positive means of disconnect adjacent to and in sight from equipment served. Provide a 120 volt receptacle located within 25 feet of equipment for service & maintenance purposes (2009 IMC sec. 306). Line voltage work by others. Cu C ovewNeq S e'er Ler.) Df DUCT NOTES 1. DUCT CONSTRUCTION and installation per latest SMACNA Standards and the 2009 • IMC as required by the local code. Provide metal duct, except as noted. Underground duct shall be "Spunstrand" factory insulated fiberglass construction. 2. BALANCING DAMPERS: Provide on all supply grille run out ducts up stream of grille. 3. DUCT INSULATION: Manville fiberglass duct wrap, type 75, FSK aluminum foil facing or equal. Supply and return ducts: Within conditioned space = R-3.3; outside bldg insulation envelope (attic) = R-7; in ground or in concrete = R-5.3; exposed in same cond. space served = none. Outside air duct in conditioned space: R-7 with vapor barrier. Exhaust duct inside build = none, in attic = R-4. 2009 WSEC, Table 14-5. 4. DUCT SEALING -GENERAL: 0 to 2" static pressure - seal all transverse joints on all ducts. Above 2"- seal seams & joints. Inside build: DuroDyne "DDS -181 "gray or approved equal per UL 181 A -M, 181B -M listed. Outside: Polyurethane, Mameco Vulkem 116. OR approved equal. 5. TURN VANES: Provide single thickness turn vanes (see detail) in all major square duct elbows, tees, or turns with inside radius less than 3/4 duct width. Square branch duct taps shall be 45 degree type per SMACNA standard. 6. FLEX DUCT (Insulated): For grille run outs up to 6 ft. long, except as noted. Provide adjustable metal elbows on all turns, unless a smooth full radius turn is made, Secure core with approved nylon or metal worm drive clamps. NO duct tape joints & screws allowed. 7. SOUND LINER: Provide sound lined metal supply & return ducts as shown on plans. Johns Manville Linacoustic RC flexible fiberglass liner with Permacote acrylic surface treatment or equal. Fabricate and install per duct liner standard of North American Insulation Manufacturer's Assoc. 8. FLEX CONNECTORS: Provide on all duct hook-ups to isolate air handling equipment (Neoprene coated fiberglass fabric type). • 9. DUCT SIZE CHANGES: Round galvanized ducts may be substituted for rectangular ducts that are NOT LINED. Provide circular equivalent of rectangular duct. Other equivalent rectangular duct sizes may be substituted to better fit space. 10. TEMPORARY DUCT CLOSURE: Seal off ductwork during construction to keep out construction dust, especially floor boots and low wall openings. NOTE !, ALL WorY-- SA -L- CotNAQI-Ng 'TO 2o1-2._ gut t -v11.463 ,-P4-•• mer:-.orAto\c,00-:. ) 1/3 'Vs" \Pe CE1Z- DIENL Va 4A. s. , cuksyrs,„,,x, Txt7 2 14 x‘.1 Grme'rereC) ‘...40 0 51.lietelLAI (AN.> \-r- SG -7\ SYv0, s, r, (g) aV16 Scre wS• Pelt - to 1 22. 6..A., s-s-s-Loe (7“, 4) 2>(1. Pri•sse,0E- se.c,v r :.-'5': -1-0 (z.:), Vt.,* t ' ' C -c -e• -1.-.-A' " 9-8--p..,;Ar4.164.4 _,..„Lat.cpacr,rot? CORRECTION LTR#A___ REVIEWED FOR ODE COMPLIANCE APPROVED AUG 1 9 2013 City of Tukwila BUILDING DIVISION t'U3 133 RECEIVED CITY OF TUKWILA AUG 0 6 2013 PERMIT CENTER 24 X16 CLEARPRINT• REVISIONS • BY 4 ,n ,... cs- ktil 0 .A, 4 X-1, 3 L ..0 4,--- 4 .......''. ..,. I.,••,,,r,,,,, .1, ,,,,,,,,T," Date Scale Drawn Job A 0 ) IA Sheet M Of Sheets