Loading...
HomeMy WebLinkAboutPermit M13-137 - TUKWILA ELEMENTARY SCHOOL - ALTERATIONTUKWILA ELEMENTARY SCHOOL 5939 S 149 ST M13-137 Parcel No.: Address: City ofirukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 3597000120 5939 S 149 ST TUKW MECHANICAL PERMIT Project Name: TUKWILA ELEMENTARY SCHOOL Permit Number: M13-137 Issue Date: 09/04/2013 Permit Expires On: 03/03/2014 Owner: Name: Address: Contact Person: Name: Address: Email: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST , TUKWILA WA 98168 KIRSTEN FAUSKO 1221 SECOND AVN , KENT WA 98032 KFAUSKO @HERMANSON. C OM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AVN , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 253-796-5892 Phone: 206-575-9700 Expiration Date: 08/25/2014 DESCRIPTION OF WORK: INSTALL ONE (1) NEW EXHAUST FAN, TWO (2) LOUVERS, AND ASSOCIATED DUCTWORK Value of Mechanical: $6,100.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signatur Fees Collected: $274.13 International Mechanical Code Edition: 2012 Date: I hereby certify that I have read an• exa fined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli - d wit , whether specified herein or not. The granting of this permit does not pr- ume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: / (� Print Name: G /(/ �n —(/ ` � �i \(Q _ ( V S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: q- • s .1....• 11111!` Alan nAi 2_117 Printeii• f19-Od-9013 PERMIT CONDITIONS Permit No. M13-137 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-137 Printed: 09-04-2013 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. nn IJi ' -1 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION y� King Co Assessor's Tax No.: ' 51 7 0001 2-0 Site Address: 69929 5 . I (c7 cS Suite Number: Floor: 1.. , New Tenant: ❑ Yes No Tenant Name: lift W) 1 i ok- 61-c VVU vt-f -&t 1 PROPERTY OWNER Name: - ``.ct sd oo\ Di f iZf *�Iob Address: 4 b O s. potty, si_ _ City: TA r & r (lo- State: Zip: , 0 t& CONTACT PERSON — person receiving all project communication Name: Kirsten Fausko Address: 1221 2nd Ave n City: Kent State: WA Zip: 98032 Phone: (253) 796-5892 Fax: (253) 796-5992 Email: kfausko@hermanson.com MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: (206) 575-9800 Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2014 Tukwila Business License No.: 09-459 Valuation of project (contractor's bid price): $ 19/ I9 D Describe the scope of work in detail: hit c (( 0 fail, �/ 1 � CZ -)vim- C c -e n,e w X I�a.ct s� a i►vd- a 3 s oot'G Use: Residential: New ❑ Commercial: New Fuel Type: Electric ❑ Gas Replacement Replacement (,lou Veit—% Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 does Revised: August 2011 bh Page 1 of 2 indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater F Appliance vent l Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan F connected to single duct l Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER THORIZED AGENT: Signature: Date: /zit/'0t " ; Print Name: Kirsten Fausko Day Telephone: (253) 796-5892 Mailing Address: 1221 2nd Ave N H:\Applications\Forms-Applications On Line\201 I Applications \ Mechanical Permit Application Revised 8-9-11 docx Revised: August 2011 bh Kent City WA 98032 State Zip Page 2 of 2 r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 3597000120 Address: 5939 S 149 ST TUKW Suite No: Applicant: TUKWILA ELEMENTARY RECEIPT Permit Number: M13-137 Status: PENDING Applied Date: 07/24/2013 Issue Date: Receipt No.: R13-02205 Initials: User ID: TLS 1670 Payment Amount: $274.13 Payment Date: 07/24/2013 03:36 PM Balance: $0.00 Payee: KIRSTEN FAUKSO - HERMANSON CO TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 193305 ACCOUNT ITEM LIST: Description 274.13 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 219.30 000.345.830 54.83 Total: $274.13 dnr• Dnrn in4_AA 171.:..4..d. n7 eA nria INSPECTION RECORD. Retain a copy with permit. INSPECTION NO. PERMIT NO: •-•••.i:±91 0113- 37 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 v-_ Proytct: I. 1-11.4W1LA £LEAfNTAckg Type of Inspection: FII A -L A54s3q S . s•; 11-4c: Date Called: Special Instructions:. Date. Wanted: CI --' l I _ 13 a. P.m Requester: Phone N : - �4G--6L41-'x°550 pproved per applicable codes. Corrections required prior to approval COMMENTS: tor: Date: NSPECTION FEE R UIRED. Prior t, next inspection, fee must be id at 6300.Southcente Blvd.. Suite 100. Call to schedule reinspection. RUSKIN® FILEC'�'P�f Prnita64 Geo. 3900 Dr. Greaves Rd. • Kansas City, MO 64030 • (816) 761-7476 FAX (816) 765-8955 DIBD2 and DIBD23 CURTAIN TYPE DYNAMIC FIRE DAMPERS 11/2 AND 3 HOUR UL555 RATED FOR USE IN DYNAMIC AND STATIC SYSTEMS APPLICATION DIBD2 fire dampers can be installed vertically in walls or horizon- tally in floors with fire resistance ratings of less than 3 hours. The DIBD2 carries a 11/2 hour UL fire damper label and is classified as a dynamic damper for use in HVAC systems that remain in opera- tion during a fire. DIBD23 fire dampers can be installed vertically in walls or horizon- tally in floors with fire resistance ratings of 3 hours or more. The DIBD23 carries a 3 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in opera- tion during a fire. DYNAMIC CLOSURE RATINGS 4000 fpm (20.3 m/s) vertical mount only, up to 24" x 24" (610 x 610). 3000 fpm (15.2 m/s) vertical and horizontal mount, up to 24" x 24" (610x610). 2000 fpm (10.2 m/s) vertical or horizontal mount on all sizes. 4 in. w.g. (1kPa) maximum pressure on all sizes. STANDARD CONSTRUCTION FRAME AND BLADES MATERIAL Galvanized steel or stainless steel (in gages required by UL list- ing R-5531). CLOSURE SPRINGS 301 stainless steel constant force or spring clip type. FUSIBLE LINK 165°F (74°C) is standard. 212°F (100°C) and 285°F (141°C) are available. DAMPER SIZES The sizes listed below are for A Style dampers. Refer to pages 2 and 3 for sizes of other style dampers. MINIMUM SIZE Vertical Installation — 4"w x 4"h (102 x 102) Horizontal Installation — 6"w x 6"h (152 x 152) for dampers o larger than 24"w or 24"h (610 or 610). Dampers larger t an 24"w or 24"h (610 or 610) have a minimum size of 10" or 10"h (254 or 254). MAXIMUM SIZE Single Section Vertical Installation — 33"w x 36"h (838 x 914) Horizontal Installation — 24"w x 24"h (610 x 610) Multiple Section Vertical Installation — 72"w x 48"h (1829 x 1219), 48 72"h (1219 x 1829) or 120"w x 24"h (3048 x 610)" "90"w x 241h (2286 x 610) for DIBD23 Horizontal Installation — 36"w x 48"h (914 x 1219) OPTIONS • FM Approvals as Specification Tested Product. • Switch Package to remotely indicate damper blade position. • FAST Angle for one side angle installations. • G Style for grille applications. • GA, Grille Access Type for out of the wall/floor and no angle grille applications. - • OW, Out of Wall Type for out of wall/floor installations. Sleeve of various lengths and gages to insure field compliance with UL installation requirements. • Access Door factory mounted in common sleeve to ensure compliance with UL installation requirements. NOTE: Dimensions shown in parentheses ( ) indicate millimeters. Models DIBD2 and DIBD23 meet the requirements for fire dampers established by: • National Fire Protection Association NFPA Standards 80, 90A and 101 • ICC International Building Codes • CSFM California State Fire Marshal Fire Damper Listing (#3225-245:005 and #3225-245:004) • New York City (BSA Listing #297 -71 -SA and #298 -85 -SA) UL CLASSIFIED UL555 Listing R5531 B Height REVIEWED FO CODE COMPLIANCE (A. A APPROVED Width �f127) RECEIVED AUG 9 9 2013 A STYLE FRAME AND BLADEPITY OF TUKWI FM Approvals Specification Tested Product (Option) City of Tukwila BUILDING DIVISIO Spec DIBD2 & DIBD23-612/Replaces DIBD2 & DIBD23-909 B Height A Width IN AIRSTREAM AUG 192013. PERMIT CENTE CORAECTM LTR# Taped and sealed on verti- cal sizes up to 33"w x 36"h (838 x 914) and horizontal sizes up to 24"w x 24"h (610 x 610). DIBD2 OR 23 STYLE A IN 20 GAGE FACTORY SLEEVE ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITH UT NOTICE OR OBLIGATION. ©Ruskin June 2012 19/ DAMPER STYLES AND SIZES "B" Style - Blades out of airstream for high free area applications MINIMUM SIZE Vertical Installation — 4"w x 4"h (102 x 102) Horizontal Installation — 6"w x 4"h (152 x 102) for dampers no larger than 24"w or 21"h (610 or 533). Dampers larger than 24"w or 21"h (610 or 533) have a minimum size of 10"w or 8"h (254 or 203) MAXIMUM SIZE Single Section Vertical Installation — 33"w x 32"h (838 x 813) Horizontal Installation — 24"w x 21"h (610 x 533) Multiple Section Vertical Installation — 72"w x 45"h (1829 x 1143), 48"w x 69"h (1219 x 1753) or 120"w x 21"h (3048 x 533)- -90"w x 21"h (2286 x 533) for DIBD23 Horizontal Installation — 36"w x 42"h (914 x 1067) A = Duct Width Taped and sealed on vertical sizes up to 33'w x 32'h (838 a 813) and horizontal sizes up to 24'w a 21'h (610 a 533). DIBD2 or 23 STYLE B IN FACTORY SLEEVE B = Duct Height H = Overall Damper Height L = Sleeve Length (38) "BC" Style - Welded "B" style for high pressure, high free area applications MINIMUM SIZE Vertical Installation — 4"w x 4"h (102 x 102) %1 Horizontal Installation — 6"w x 4"h (152 x 102) for dampers no larger than 24"w or 21"h (610 or 533). Dampers larger than 24'w or 21"h (610 or 533) have a minimum size of 10"w or 8"h (254 or 203). MAXIMUM SIZE Single Section Vertical Installation — 33"w x 32"h (838 x 813) Horizontal Installation — 24"w x 21 "h (610 x 533) Multiple Section Vertical Installation — 72'w x 45"h (1829 x 1143), 48"w x 69"h (1219 x 1753) or 120"w x 21"h (3048 x 533)" "90"w x 21"h (2686 x 533) for DIBD23 Horizontal Installation — 36"w x 42"h (914 x 1067) A \ A = Duct Width B = Duct Height H = Overall Damper Height 9" (229) Damper must be ordered with minimum 18 gage (1.2) x 9" (229) factory sleeve. C and WC Style - Sealed (C) or welded (WC) square or rectangular transition for maximum free area applications MINIMUM SIZE Vertical Installation — 4"w x 3"h (102 x 76) Horizontal Installation — 4"w x 3"h (102 x 76) for dampers no larger than 22"w or 20"h (559 or 508). Dampers larger than 22"w or 20"h (559 or 508) have a minimum size of 8"w or 7"h (203 or 178). MAXIMUM SIZE Single Section Vertical Installation — 31'w x 31"h (787 x 787) Horizontal Installation — 22"w x 20"h (559 x 508) Multiple Section Vertical Installation — 70'w x 44'h (1778 x 1118), 46"w x 68"h (1168 x 1727) or 118"w x 20"h (2997 x 508)- -88"w x 20"h (2235 x 508) for DIBD23 Horizontal Installation 34"w x 42"h (864 x 1067) A + 2" ( (A+51) Taped and sealed on sizes up to 31"w x 31"h (787 z 787) for vertical Installation and 22"w x 20"h (559 x 508) for horizontal Installation. 2" (A (A + 51) A = Duct Width B = Duct Height H = Overall Damper Height L = Sleeve Length A D BD2 OR 23 STYLE C IN FACTORY SLEEVE 1l/z" (38) for C 21/2" (64) for WC -►I L._� 1"(25) CR and WR Style - Sealed (CR) or welded (WR) round transition for 100% free area applications MINIMUM SIZE Vertical Installation — 3" (76) diameter Horizontal Installation — 4" (102) diameter MAXIMUM SIZE Vertical Installation Single Section — 31" (787) diameter. Multiple Sections — 44' (1118) diameter Horizontal Installation Single Section — 20" (508) diameter Multiple Sections — 34" (864) diameter D = Diameter H = Overall Damper Height L = Sleeve Length Taped and sealed on sizes up to 31" (787) in diameter for vertical installation and 20" (508) in diameter for horizontal installation. 0+2" (D+51) ts II \DIBD2 OR Die. 111123 STYLE CR IN FACTORY SLEEVE 1 r/2' (38) for CR 21/2" (84) for WR -.-i r-� I 1"(25) DAMPER STYLES AND SIZES CO and WO Style — Sealed (CO) or welded (WO) oval transition for 100% free area applications MINIMUM SIZE Vertical Installation — 4"w x 3"h (102 x 76) Horizontal Installation — 4"w x 3"h (102 x 76) for dampers no larger than 22"w or 20"h (559 or 508). Dampers larger than 22"w or 20Th (559 or 508) have a minimum size of 8"w or 7"h (203 or 178). MAXIMUM SIZE Vertical Installation Single Section — 31"w x 31"h (787 x 787) Multiple Sections — 70"w x 44"h (1778 x 1118), 46"w x 6811 (1168 x 1727) or 118"w x 20"h (2997 x 508)** "88"w x 20T11 (2235 x 508) for DIBD23 Horizontal Installation Single Section — 22"w x 20"h (559 x 508) Multiple Sections — 34"w x 42"h (864 z 1067) Taped and sealed on sizes up to 31 "w a 31"h (787 x 787) for vertical installation and 22"w a 20"h (559 a 508) for horizontal installation. 1'12 (38) for CO J 2112* (64) for WO . H A = Duct Width B = Duct Height H = Overall Damper Height L = Sleeve Length DIBD2 OR 23 STYLE CO IN FACTORY SLEEVE 1"(25) LO, LR and R Style — Non -sealed oval (LO) or round (LR, R) transitions for low pressure applications. LO and LR transitions offset for 100% free area applications. R transition centered for use when 100% free area not required. MINIMUM SIZE Vertical Installation LR, R Styles — 3" (76) diameter LO Style — 4"w x 3"h (102 x 76) Horizontal Installation LR, R Styles — 4" (102) diameter LO Style — 4"w x 3"h (102 x 76) MAXIMUM SIZE Vertical Installation LR, R Styles — 31" ( 787) diameter LO Style — 31"w x 31"h (787 x 787) Horizontal Installation LR, R Styles — 20" (508) diameter LO Style — 22"w x 20"h (559 x 508) STYLE LO STYLE R STYLE LR 0.2" A = Duct Width B = Duct Height H = Overall Damper Height D = Diameter L = Sleeve Length 11/2" (38) when damper is sleeved 21/2" (64) when damper is not sleeved 21/2'464)- H.._ L • ... 1" (25) ASSEMBLY AND DIMENSIONAL INFORMATION Dampers normally fabricated approximately ,/4" (6) less than given duct dimensions. A (width) and B (height) dimensions shown describe maximum UL Classified sizes. Ruskin recommends the authority having jurisdiction, the engineer and the contractor agree on the installation design prior to installation. DIBD2 and DIBD23 multiple section dampers ordered without sleeves are shipped in individual sections, for field assembly. DIBD2 and DIBD23 multiple section dampers ordered with factory furnished sleeves are normally shipped in complete assemblies. If TDF or other flanged breakaway connections are to be used, order dampers with factory furnished sleeves actual size. A STYLE DAMPERS VERTICAL INSTALLATION Important Note: Dampers larger than 33" x 36" (838 x 914) are multiple section dampers consisting of equal sections no larger than 24° x 24" (610 x 610). Single Section Dampers Multiple Section Dampers Max.A 6 36"(914) Max. 24"(810) Max. x } 9 24' (610) Max. A 90 (2286) Max. A 120'(3048) Mex. h,� s"`�'Blade " _ tD ensio s e (610) 6 (152) 11/2 (38) I24" A 120'(3048) Mex. h,� s"`�'Blade " _ tD ensio s 777.1•I Fl. �. 6 (152) 11/2 (38) 7 (178) 11/2 (38) 8 (203) 13/4 (44) 9 (229) 13/4 (44) 10 (254) 13/4 (44) 11 (279) 2 (51) 12 (305) 2 (51) 13 (330) 23/3 (60) 14 (356) 23/4 (60) 15 (381) 25/e (67) 16 (406) 25/e (67) 17 (432) 25/e (67) 18 (457) 23/4 (70) 19 (483) 23/4 (70) 20 (508) 31/4 (83) 21 (533) 31/4 (83) 22 (559) 31/2 (89) 23 (584) 31/2 (89) 24 (610) 31/2 (89) 25 (635) 3 (76) 26 (660) 3 (76) 27 (686) 31/4 (83) 28 (711) 31/4 (83) 29 (737) 31/2 (89) 30 (762) 31/2 (89) 31 (787) 31/2 (89) 32 (813) 35/9 (92) 33 (838) 35/9 (92) 34 (864) 37/9 (98) 35 (889) 37/e (98) 36 (914) 4 (102) Dimensions shown in parentheses ( ) indicate millimeters. HORIZONTAL INSTALLATION Important Note: Dampers larger than 33" x 36" (838 x 914) are multiple section dampers consisting of equal sections no larger than 24" x 24° (610 x 610). Single Section Dampers Multiple Section Dampers B 24"(610) Max. X A 18" (457) Max. e 48 ( 219) Max. A 39"(914) Max. A 36" (9 4) -- Max. x e 48" ( 219) Max. EI 24"(810) Max. ', '. .) ZBlade s; Dimensions3 6 (152) 11/2 (38) 7 (178) 11/2 (38) 8 (203) 13/4 (44) 9 (229) 13/4 (44) 10 (254) 13/4 (44) 11 (279) 2 (51) 12 (305) 2 (51) 13 (330) 2 (51) 14 (356) 2 (51) 15 (381) 23/s (60) 16 (406) 23/6 (60) 17 (432) 23/6 (60) 18 (457) 25/a (67) 19 (483) 25/a (67) 20 (508) 23/4 (70) 21 (533) 23/4 (70) 22 (559) 3 (76) 23 (584) 3 (76) 24 (610) 3 (76) Dimensions shown in parentheses ( ( indicate millimeters. Important Notes: 1. Dampers larger than 24" x 24" (610 x 610) are multiple sec- tion dampers consisting of equal sections no larger than 18" x 24" (457 x 610). 2. Dampers larger than 24"w or 24"h (610 x 610) have a mini- mum size of 10"w or 10"h (254 x 254). B AND BC STYLE DAMPERS Single Section Dampers 33• A(838) Max. J 32 2 ' (813) A 24M x. VERTICAL INSTALLATION Multiple Section Dampers A 72'(1829) Max. 0 E- .-9 g -E---. B iii -Till H H For dampers lamer than 24" (610) W .4 (102) 536 (146) e " _ i 5 (127) 636 (171) (197) 7 6 (152) 73/4 (197) (203) 103/. 7 (178) 834 (222) (298) 10 8 (203) 936 (248) (279) 133/. 9 (229) 1134 (298) 103/. (273) 10 (254) 1234 (324) 113/. (298) 11 (279) 133/. (349) (451) 16 12 (305) 143/. (375) (432) 193/. 13 (330) 1534 (400) (527) 19 14 (356) 163/. (425) (508) 223/. 15 (381) 1734 (451) (603) 16 (406) 183/. (476) 17 (432) 2034 (527) 1936 (502) 18 (457) 213/. (552) 203/. (527) 19 (483) 2236 (578) 213/. (552) 20 (508) 233/. (603) 223/. (578) 21 (533) 2334 (603) 22 (559) 2534 (654) 23 (584) 263/4 (679) 24 (610) 2734 (705) 25 (635) 2834 (730) 26 (660) 2934 (756) 27 (686) 3034 (781) 28 (711) 313/. (806) 29 (737) 3234 (832) 30 (762) 3334 (857) 31 (787) 3434 (883) 32 (813) 353/. (908) A 72'(1829) Max. 0 E- .-9 g -E---. BIZ gni iii -Till 1 45• ((1143) Max. II _II Iii ') i (. 1 it B H • 1, (533) vel e " _ i (171) t 1 ✓ Important Note: Dampers larger than 33" x 32" (838 x 813) are multiple section dampers consisting of equal sections no larger than 24" x 24" (610 x 610) overall. To determine the overall height (H dimension) of double high and triple high damper assemblies: Add 23/4" (70) to the B dimension. For example, a 24" (610) double high assembly is 263/4" (679) overall height. A 65" (1651) triple high assembly is 673/4" (1721) overall height. The bottom sections on double and triple high assemblies are Style A dampers. Dimensions shown in parentheses ( ) indicate millimeters. A 120'(3048) Max. A 48"(1219) r- Max. � ' i illMIN 77'9 II _II Iii ') i (146) 1 it B H • 1, (533) vel e " 63/. (171) 6 (152) 21^ (197) 7 69' (1753) Max. B (533) I ,.._________,,_--L„-----.,,,------\ (203) 103/. l'....:In447''''''' .)...7.1=-... (229) 113/. Ec=y3.H2- sc_-�i -__��Eva 77'9 4 _II Iii ') i (146) 1 it B H • 1, (533) vel A 90"(2286) Max. Mil Pte;= =_ 77'9 H 4 (102) 53/4 (146) 5 e " 63/. (171) 6 (152) 21^ (197) 7 (178) 83/. (533) I ,.._________,,_--L„-----.,,,------\ (203) 103/. (273) _Li Single Section Dampers A Max. _ f� 80 355 B H 21'(533) Max. HORIZONTAL INSTALLATION Important Notes: 1. Dampers larger than 24" x 21" (610 x 533) are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. 2. Dampers larger than 24"w or 21"h (610 x 533) have a minimum size of 10"w or 8"h (254 x 203). To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to B dimension on dampers over 21" (533) through 24" (610) and 51/2" (140) on all other dampers. For example, a damper with a 28" (711) B dimension has an overall H dimension of 331/2" (851). Dimensions shown in parentheses ( ) indicate millimeters. Multiple Section Dampers F1-8" (d57)� Max 711 J B 42" (1067) Max. _-_ A 38" (914) Max. B 1 H 4 (102) 53/4 (146) 5 (127) 63/. (171) 6 (152) 73/. (197) 7 (178) 83/. (222) 8 (203) 103/. (273) 9 (229) 113/. (298) 10 (254) 123/. (324) 11 (279) 133/. (349) 12 (305) 143/. (375) 13 (330) 153/. (400) 14 (356) 163/. (425) 15 (381) 173/. (451) 16 (406) 183/. (476) 17 (432) 193/. (502) 18 (457) 203/. (527) 19 (483) 213/. (552) 20 (508) 223/. (578) 21 (533) 233/. (603) Important Notes: 1. Dampers larger than 24" x 21" (610 x 533) are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. 2. Dampers larger than 24"w or 21"h (610 x 533) have a minimum size of 10"w or 8"h (254 x 203). To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to B dimension on dampers over 21" (533) through 24" (610) and 51/2" (140) on all other dampers. For example, a damper with a 28" (711) B dimension has an overall H dimension of 331/2" (851). Dimensions shown in parentheses ( ) indicate millimeters. Multiple Section Dampers F1-8" (d57)� Max 711 J B 42" (1067) Max. _-_ A 38" (914) Max. A 38^(914) Max. E ne ca_ TIME 1 71 B 21"T(573) H Max. r- i { A 38^(914) Max. E ne ca_ . 6.3 a B 42 (1067) Max. �a'a�_ d� CSdBtuS- C, CO, WC, WO, LO AND LC STYLE DAMPERS Single Section Dampers Important Note: Dampers larger than 31" x 31" (787 x 787) are multiple sec- tion dampers consisting of equal sec- tions no larger than 24" x 24" (610 x 610) overall. To determine the overall height (H dimension) of double high and triple high damper assemblies: Add 33/4" (95) to the B dimension. For example, a 24" (610) double high assembly is 273/4" (705) overall height. A 64" (1626) triple high assembly is 673/4" (1721) overall height. The bottom sections on double and triple high assemblies are Style A dampers with blades in the air stream. VERTICAL INSTALLATION Multiple Section Dampers A 2' A. (51) A 118" (299:) Max. FM S ReFa�M SER s)gIMo9. as e qs � -P.�J 11111 RPI_ g_ n i il 135t1) H A+2" A (51) A _- � 11/1" (2235) Max. H -P.�J Re—I RPI_ g_ n i B 68" (1 61/a l 5 l B20' H ''S508 Mas) 1 A + 2" (A 51) Max. A 70' (1118) Max. -1 1' (25) M _- _- H 3 1111 \ 1 44" (1118) Max. e B 68" (1 61/a (171) 5 0 iiM II—_ �1 - H A * 2" A+ (51) Max. A 48"(1185) Max. ...,,_:. 1 NH H 3 (76) 51/. (146) iir...____,__ B 68" (1 61/a (171) 5 0 iiM 7114 (197) Dimensions shown in paren- theses ( ) indicate millimeters. Single Section Dampers HORIZONTAL INSTALLATION Multiple Section Dampers Important Notes: 1. Dampers larger than 22" x 20" (559 x 508) are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. 2. Dampers larger than 22"w or 20"h (559 x 508) have a mini- mum size of 8"w or 7"h (203 x 178). To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to B dimension on dampers over 20" (508) through 24" (610) and 51/2" (140) to the B dimen- sion on all other dampers. For example, a 24" (610) double high assembly is 271/2" (699) overall height. A 40" (1616) double high assembly is 451/2" (1156) overall height. A (A . 51)..---.. A 34"(884) Max. 1 B 42" (1057) Max. B H 3 (76) 51/. (146) 4 (102) 61/a (171) 5 (127) 7114 (197) 6 (152) 81!. (222) 7 (178) 91/. (248) 8 (203) 1114 (298) 9 (229) 1214 (324) 10 (254) 131/. (349) 11 (279) 141/4 (375) 12 (305) 151/4 (400) 13 (330) 161/4 (425) 14 (356) 171!4 (451) 15 (381) 18114 (476) 18 (406) 201/4 (527) 17 (432) 211!4 (552) 18 (457) 221/. (578) 19 (483) 231!4 (603) 20 (508) 231/4 (603) 21 (533) 255/4 (654) 22 (559) 2614 (679) 23 (584) 271/4 (705) 24 (610) 281/. (730) 25 (635) 291/4 (756) 28 (660) 301/. (781) 27 (686) 311!4 (806) 28 (711) 321/. (832) 29 (737) 331/4 (857) 30 (762) 341/. (883) 31 (787) 351!4 (908) Dimensions shown in paren- theses ( ) indicate millimeters. Single Section Dampers HORIZONTAL INSTALLATION Multiple Section Dampers Important Notes: 1. Dampers larger than 22" x 20" (559 x 508) are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. 2. Dampers larger than 22"w or 20"h (559 x 508) have a mini- mum size of 8"w or 7"h (203 x 178). To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to B dimension on dampers over 20" (508) through 24" (610) and 51/2" (140) to the B dimen- sion on all other dampers. For example, a 24" (610) double high assembly is 271/2" (699) overall height. A 40" (1616) double high assembly is 451/2" (1156) overall height. A (A . 51)..---.. A 34"(884) Max. 1 B 42" (1057) Max. Dimensions shown in paren- theses ( ) indicate millimeters. B H 3 (78) 51/4 (146) 4 (102) 61!4 (171) 5 (127) 71/. (197) 6 (152) 81/4 (222) 7 (178) 101/. (273) 8 (203) 1114 (298) 9 (229) 121/4 (324) 10 (254) 131/. (349) 11 (279) 141/4 (375) 12 (305) 151/4 (400) 13 (330) 181/4 (425) 14 (356) 171/. (451) 15 (381) 181/4 (476) 16 (406) 191/4 (502) 17 (432) 201!4 (527) 18 (457) 2114 (552) 19 (483) 221/4 (578) 20 (508) 231/4 (603) Dimensions shown in paren- theses ( ) indicate millimeters. CR, WR AND LR STYLE DAMPERS Single Section Dampers 0.51 (D+51) i D 31" H 1" (25) VERTICAL INSTALLATION Multiple Section Dampers Important Note: Dampers larger than 31" (787) diameter are multiple section dampers consisting of equal section:; no larger than 24" x 24" (610 x 610) overall. To determine the overall height (H dimension) of double high damper assemblies: Add 33/4" (95) to D dimen- sion on dampers. For example, a 40" (1016) double high assembly is 433/4" (1111) overall height. The bottom sec- tions on double high assemblies are Style A dampers with blades in the air stream. 1' (25) Dimensions shown in paren- heses ( ( indicate millimeters. Single Section Dampers D.2" (0 . 51) HORIZONTAL INSTALLATION Multiple Section Dampers Important Note: Dampers larger than 20" (508) diameter are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to D dimen- sion on dampers over 20" (508) through 25" (635) and 51/2" (140) on all other sizes. For example, a 24" (610) double high assembly is 271/2" (699) overall height. Nol B H 3 (76) 53/4 (146) 4 (102) 61/, (171) 5 (127) 71/4 (197) 6 (152) 811. (222) 7 (178) 9./4 (248) 8 (203) 113/. (298) 9 (229) 121/4 (324) 10 (254) 131/. (349) 11 (279) 141/. (375) 12 (305) 151/4 (400) 13 (330) 1631. (425) 14 (356) 1711. (451) 15 (381) 181/. (476) 18 (406) 203/4 (527) 17 (432) 213/4 (552) 18 (457) 223/4 (578) 19 (483) 233/4 (603) 20 (508) 233/. (603) 21 (533) 25./4 (654) 22 (559) 261/, (679) 23 (584) 271/. (705) 24 (610) 283/4 (730) 25 (635) 291/. (756) 26 (660) 303/4 (781) 27 (686) 31114 (806) 28 (711) 323/, (832) 29 (737) 333/. (857) 30 (762) 341/. (883) 31 (787) 353/4 (908) Dimensions shown in paren- heses ( ( indicate millimeters. Single Section Dampers D.2" (0 . 51) HORIZONTAL INSTALLATION Multiple Section Dampers Important Note: Dampers larger than 20" (508) diameter are multiple section dampers consisting of equal sections no larger than 18" x 24" (457 x 610) overall. To determine the overall height (H dimension) of double high damper assemblies: Add 31/2" (89) to D dimen- sion on dampers over 20" (508) through 25" (635) and 51/2" (140) on all other sizes. For example, a 24" (610) double high assembly is 271/2" (699) overall height. Nol Dimensions shown in paren- theses ( ) indicate millimeters. B H 3 (76) 51/4 (146) 4 (102) 63/4 (171) 5 (127) 73/4 (197) 6 (152) 8./4 (222) 7 (178) 10./4 (273) 8 (203) 113/. (298) 9 (229) 123/. (324) 10 (254) 133/4 (349) 11 (279) 143/4 (375) 12 (305) 153/. (400) 13 (330) 163/4 (425) 14 (356) 17./4 (451) 15 (381) 183/. (476) 16 (406) 193/. (502) 17 (432) 203/. (527) 18 (457) 213/4 (552) 19 (483) 223/. (578) 20 (508) 233/. (603) Dimensions shown in paren- theses ( ) indicate millimeters. LABOR SAVER OPTIONS TDF OR DUCTMATE BREAKAWAY CONNECTIONS Meet UL breakaway connection requirements without chang- ing connectors. Ruskin fire dampers can be installed using non -matched flange connections for the breakaway require- ment. Any flange connection can mate to a different type or model on Ruskin fire dampers. FAST MOUNTING ANGLE FAST mounting angles are used in lieu of conventional, eight piece mounting angles and are installed on only one side of the wall when used with Ruskin DIBD2 fire dampers. The FAST angle can be fastened directly to the metal stud underneath the fire rated gypsum wallboard. LEED 2009 Information VOC Content (WI) - 0 Manufacturing Locations (MR Credit 5.1) Mira Loma, CA 91752 Parsons, KS 67357 Lexington, KY 40509 Fairmont, WV 26554 Recycled Content (MR Credit 4.1 & 4.2) 7.5% Post Consumer 7.5% Pre -Consumer Post Industrial Approximate Damper Assembly Weight 6 lbs. per sq. ft. without sleeves 10 lbs. per sq. ft. with 12" 20 ga. sleeves SUGGESTED SPECIFICATION FOR DIBD2 Furnish and install, at locations shown on the plans, dynamic fire dampers tested, constructed and labeled in accordance with the latest edition of UL Standard 555. Dampers shall have a fire rating of 11/2 hours and shall meet the requirements of the latest edition of NFPA90A. Each damper shall include a 165°F (74°C) or 212°F (100°C) fusible link (specifier select) and shall be labeled for use in dynamic systems. Dampers labeled for use in static systems only are not permitted. The damper shall be rated for dynamic closure at 2000 fpm (10.16 m/s) and 4 inches w.g. (1 kPa) static pressure SUGGESTED SPECIFICATION FOR DIBD23 and shall be rated to close with airflow in either direction. Each dynamic fire damper shall include a steel sleeve and mount- ing angles furnished by the damper manufacturer to ensure appropriate installation. Submittal information shall include the fire protection rating, maximum velocity/pressure ratings and the manu- facturer's UL installation instructions. The dampers shall be installed in accordance with the manufacturer's UL installation instructions. Dynamic fire dampers shall be curtain type Ruskin model DIBD2. Furnish and install, at locations shown on the plans, dynamic fire dampers tested, constructed and labeled in accordance with the latest edition of UL Standard 555. Dampers shall have a fire rating of 3 hours and shall meet the requirements of the latest edition of NFPA90A. Each damper shall include a 165°F (74°C) or 212°F (100°C) fusible link (specifier select) and shall be labeled for use in dynamic systems. Dampers labeled for use in static systems only are not permitted. The damper shall be rated for dynamic closure to a minimum 2000 fpm (10.16 m/s) and 4 inches w.g. (1 kPa) RUSKIN® 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 www.ruskin.com static pressure and shall be rated to close with airflow in either direction. Each dynamic fire damper shall include a steel sleeve and mount- ing angles furnished by the damper manufacturer to ensure appropriate installation. Submittal information shall include the fire protection rating, maximum velocity/pressure ratings and the manu- facturer's UL installation instructions. The dampers shall be installed in accordance with the manufacturer's UL installation instructions. Dynamic fire dampers shall be curtain type Ruskin model DIBD23. Printed on recycled paper using vegetable based inks •"1/44 M •PERMIT COORD COPY IP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-137 DATE: 08/19/13 PROJECT NAME: TUKWILA ELEMENTARY SCHOOL SITE ADDRESS: 5939 S 149 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: 1)1- Building Division Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete k Incomplete n Corn ments: DUE DATE: 08/20/13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route '1Xf Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/17/13 Approved n Approved with Conditions el Not Approved (attach comments) Ti Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-137 DATE: 07-24-13 PROJECT NAME: TUKWILA ELEMENTARY SCHOOL SITE ADDRESS: 5939 S 149 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: )tbl_.PIA AK ill— Public b ilding Division Works it Ni4- 7-i:3 Fire Prevention III Structural Planning Division Permit Coordinator I DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: DUE DATE: 07-30-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required u REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-27-13 Approved ❑ Approved with Conditions Not Approved (attach comments) ig Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 8-'1-A - I� Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 i • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIVED AUG 19 2013 • COW/JUNI r DEVELOPMENT REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 8/19/2013 • • Plan Check/Permit Number: M 13-137 ❑ Response to Incomplete Letter # El Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ . Revision requested by a City Building Inspector or Plans Examiner Project Name: Tukwila Elementary School Project Address: 5939 S 149 St Contact Person: Lukas Paulsen Phone Number: (206) 641-4550 Summary of Revision: To avoid a penetration into the corridor, we found there was an existing exhaust duct that serves the janitors closet and the restroom. The exhaust duct that goes through to the roof is sized to adequately handle the additional 300 cfm from the exhaust fan. We will demo the exhaust in the janitors closet, then install the new exhaust fan and associated ductwork. The makeup air will come from the gap underneath the closet door, supplemented by a transfer between the classroom next to it. A fire damper will be installed in the wall penetration of the ductwork (fire damper submittal attached). Sheet Number(s): M0.00, M2.01 "Cloud" or highlight all areas of revision including date Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ev s rn \applications\forms-applications on Zine\revision submittal Created: 8-13-2004 Revised: J q� � - • City of Tukwila Jim Haggerton, Mayor r � Department of Community Development Jack Pace, Director August 7, 2013 Kirsten Fausko 1221 Second Av N Kent, WA 98032 RE: Correction Letter #1 Mechanical Permit Application Number M13-137 Tukwila Elementary School — 5939 S 149 St Dear Ms. Fausko, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, 7e0j2 Bill Rambo Permit Technician File No. M13-137 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: July 30, 2013 Project Name: Tukwila Elementary Permit # M13-137 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. The transfer opening from the Storeroom C115 to the corridor shows a fire damper on the plan. Since this opening penetrates into a corridor a combination fire -smoke damper would be required. Please revise the plan to show this change. Also provide a spec sheet on the specific fire -smoke damper proposed and the method of smoke activation for the smoke portion of the damper. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. Contractors or Tradespeople Printer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LW to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite/Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2014 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat, Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role . Effective Date Expiration Date NICOLAISEN, KNUT H Partner/Member 08/05/2010 Amount BROCK, DANIEL L Partner/Member 08/05/2010 GL0370326110 FOX, DEAN M Partner/Member 08/05/2010 HENGEL, STEPHEN A Partner/Member 08/05/2010 American Zurich Insurance Comp DYCKMAN, KENNETH A Partner/Member 08/05/2010 ROBINETT, PAUL J Partner/Member 08/05/2010 10 HERMANSON, RICHARD L Partner/Member 01/01/1980 ALMON, KEVIN Partner/Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner/Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date 4 WESTERN SURETY CO 929381801 01/01/2006 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount Received Date $12,000.00 12/01/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 Zurich American Ins Co GL0370326110 08/21/2013 08/21/2014 $1,000,000.0008/16/2013 11 American Zurich Insurance Comp GL0370326109 08/21/2012 08/21/2013 $1,000,000.0008/14/2012 10 American Zurich Insurance Comp GL0370326108 08/21/2011 .08/21/2012 $1,000,000.00 08/18/2011 9 American Zurich Ins Co GL0370326107 08/21/2010 08/21/2011 $1,000,000.00 08/18/2010 8 GL0370326106 08/21/2008 08/21/2010 $1,000,000.0008/24/2009 httns://fortress.wa. aov/lni/bbip/Print.aspx 09/04/2013 100 C�) 512X1001 A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP EWT EXIST EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ IBC ICW ID MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL CEILING TILE ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/DEGREES DIAMETER DAMPER DOWN DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED FURNISHED AND INSTALLED FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ INTERNATIONAL BUILDING CODE INDUSTRIAL COLD WATER INSIDE DIAMETER/DIMENSION SYSTEM BY CONTRACTOR BY OWNER E EER MC N N WG PLV KW LAT LB/LBS LF/LIN FT LPG LPS LVG LWA LWG LWT MAX MAU MBH MCA MD MFR MISC MIN MPS MT MTD MUW NA NC NG/NGAS NIC NO NPW N -R OA/OSA OBD OD PCF PD PH POC P/PRESS PSI PSIG QTY R RA RD/RND REF REQ RESID RF RG RL RPM RS S SA SAT SD S/D S_C SEER SENS SL SM SPEC SO SOG SP SF SS STRUC TA TEMP TBD TOD TOS TOT TSP TSTAT TYP UH UNO V VD VEL VERT VFD VOL W WB WG WI W/SF WSEC NVERT ELEVATION NTEGRATED ENERGY EFFICIENCY RATIO NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND/POUNDS LINEAL FOOT/FEET LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MOUNTED MAKE-UP WATER NOT APPLICABLE NORMALLY CLOSED/NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REQUIRED RESIDENTIAL RELIEF REFRIGERANT DISCHARGE GAS REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION/SUPPLY AIR TEMPERATURE SMOKE DETECTOR SLIP & DRIVE CONNECTION SEATTLE ___ CODE SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SOUND LINED SHEETMETAL SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET STAINLESS STEEL STRUCTURAL TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE FACTOR FILE COPY ..rmftNa t4A1:5 - I3� Pnn review approval is subjed to errors and of construction documents not authorize t, :rs :ion of any adopted tole or ordinance. Receipt Ly311'oved Fi id Copy ;.tint a>l : ►T By Date: (.t CityOrrukwila ..f .T. 1r%1 I" Mit/IMAM MECHANICAL LEGEND flaw 1.1Q,Kazi t10X10( ,10X1oa i-10)(10 Lel ,10X10® 10X10;,' ,10X10© RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY _ 1p1 �, ROUND DUCT - UP/TOWARD ��W ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY DUCT OVERLAP BOOT TAP 45' TAP VOLUME DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) 16X16SL FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE @CARBON DIOXIDE SENSOR Co CARBON MONOXIDE SENSOR SENSOR COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT (SL) MO CD1-100 80 TSTAT/TEMP SENSOR HUMIDITY SENSOR SMOKE DETECTOR sP STATIC PRESSURE a EXISTING DUCTWORK DEMO DUCTWORK 0 D a a ] a a a (® a a-CHWS /CHWR-5 a- RL/RS-5 NG -S LPG -5 a-CDWS /CDWR-s a- HWS /HWR-S a-- COND -5 a- FOV -3 a- FOS /FOR -5 a-- RDG -5 WALL -MOUNTED GRILLE PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP PRESS REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY/RETURN REFRIGERANT LIQUID/SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY/RETURN HEATING WATER SUPPLY/RETURN CONDENSATE FUEL OIL VENT FUEL OIL SUPPLY/RETURN REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 IBC, 2012 WSEC, 2012 IMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5'F (10'F FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE C4080. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS (Sc CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED. (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -USE SECTIONT909.5S 0OFTTHES2012 IBCN FOR MAX ALDLOWABLLEKLEAKKAGE (AREA, FO'LLOWINGATHEBGU DELINESOFOROTIGHT STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING. SEE ENERGY CODE CHAPTER R403. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal i end may include additional plan review fees. g_VTAPATE,- PERMIT d . OUIRED FOR: 0 Mechanical Ei°Electrical Numbing Ceres Piping City of Tukwila tpciti.DING DIVISION MINIMUM DUCT J: SULATION LAST UPDATED 10/05/12 DUCT TYPE DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM N -R INSULATION R -VALUE RESID INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R-7 R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE VARIES R-8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY AIR <55' OR >105' WITHIN CONDITIONED SPACE R-3.3 NOT REQ 1,2 1 REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-7 FOR REST OF INSTALLATION) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM * NOT REQUIRED FOR <1-1/4HEATING PIPE BETWEEN CONTROL VALVE & COIL, IF <4 FEET FROM COIL ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION DRAWING INDEX MINIMUM PIPE INSULATION LAST UPDATED: 01/09/13 FLUID DESIGN OPERATING TEMP 'F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING 'F RUN OUTS* <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER) >350 0.32-0.34 250 3.0 3.0 3.5 3.5 4.5 4.5 251-350 0.29-0.32 200 2.0 2.0 3.0 3.5 3.5 3.5 201-250 0.27-0.30 150 2.0 2.0 2.0 2.5 2.5 2.5 141-200 0.25-0.29 125 1.5 1.5 1.5 1.5 2.0 2.0 105-140 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER 40-60 0.22-0.28 100 0.5 0.5 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 <40 0.22-0.28 100 1.0 1.0 1.5 1.5 1.5 2.0 * NOT REQUIRED FOR <1-1/4HEATING PIPE BETWEEN CONTROL VALVE & COIL, IF <4 FEET FROM COIL ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg fi: HERMACL0058J M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M2.01 1ST FLOOR PLAN, ELEVATION & EQUIPMENT SCHEDULE - HVAC Revisions 08/16/13 MG REVISED PERMIT 07/25/13 MG ISSUE FOR PERMIT No. Date By Description APN NUMBER 3597000120 LEGAL DESCRIPTION NTERURBAN ADD TO SEATTLE TRACT 6 OF INTERURBAN ADDITION TO SEATTLE LESS N 20 FT LESS E 150 FT AND UNPLATTED STRIP LY W OF TRACT 6 & E OF W LINE OF 59TH AVE S SOUTH OF S 149TH ST AND N OF EXTENDED N LINE OF TRACT 40 BROOKVALE GARDEN TRACTS & UNPLATTED STRIP LY W OF W LINE OF TRACTS 6 AND 7 AND EAST OF EXTENDED C/L OF 59TH AVE SOUTH LY BETWEEN EXTENDED N AND S LINE OF TRACT 40 BROOKVALE GARDEN TRACTS TGW TRACT 7 INTERURBAN ADDITION TO SEATTLE LY W OF LINE EXTENDED FROM POINT ON N LINE OF TRACT 155.64 FT E OF NW CORNER OF E 1/2 OF SAID TRACT TO POINT ON S LINE OF SAID TRACT 156.52 FT E OF SW CORNER OF E 1/2 OF SAID TRACT TGW E 202 FT OF TRACT 39 OF BROOKVALE GARDEN TRACTS AND UNPLATTED STRIP LY E OF TRACT 39 & W OF INTERURBAN ADDITION TO SEATTLE & BETWEEN ELY PRODUCTION OF N & S LINES OF SAID TRACT TGW TRACT 40 LY E OF LINE WHICH IS 25 FT E OF AND PLW SLY PRODUCTION OF C/L OF 58TH AVE SOUTH IN TRI VISTA TERRACE AND UNPLATTED STRIP LY E OF TRACT 40 & W OF EXTENDED C/L OF 59TH AVE S & BETWEEN ELY PRODUCTION OF N & S LINES OF SAID TRACT - PARCEL 1 OF CITY OF TUKWILA LOT CONDOLIDATION NO L99-0031 RECORDING NO 9906239004 ._S 149th:St-d i 150th_St� sr. 'SUMSt ,S:152ndSt ~' l (_S_152nd_PID A7acau Casino 5outhcente rm SavtCen. Y fu Snsutst1151st St', H C--S751s[PI7 'ft '41 whitetrorse. Tavern e Q. . 5154th 5tD a153rd st,S 153rd St_`7 VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 992013 City of Tukwila BUILDING DIVISION AREA OF WORK ISSUE FOR PERMIT CORRECTKIIN LTR# 1 Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg fi: HERMACL0058J TUKWILA ELEMENTARY EXHAUST INSTALLATION 5939 S. 149TH ST. TUKWILA, WA 98168 Revisions 08/16/13 MG REVISED PERMIT 07/25/13 MG ISSUE FOR PERMIT No. Date By Description Design Team Design MG Drawn FP Checked ON Scale AS NOTED Drawing Number C-0400-02599 Project Number 1 1-1 3-02599 Issue Date 07/25/13 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX - HVAC RECEIVED e AUG 192013 PERMIT CENTER MO a 00 AREA OF WORK KEY PLAN SCALE: NONE 12:— D1MXIST 24x10 1 CAP 24x10 UP TO o EXIST EXH DUCT. Mt3 137 EXHAUST FAN SCHEDULE LAST UPDATED: 07/22/13 UNIT TUKWILA ELEMENTARY EXHAUST INSTALLATION 5939 S. 149TH ST. TUKWILA, WA 98168 BASIS OF E.S.P. MAX WEIGHT No. Date By Description TAG SERVICE/LOCATION MAKE DESIGN TYPE CONTROLS CFM IN. W.G. RPM HP V/PH SONES IN POUNDS REMARKS EF -1 IDF RM / CEILING BROAN L-500 IN-LINE THERMOSTAT 420 0.50 810 ` 232 Watts 120/1ph 4.4 36 1-6 HKKS: 1 ELECTRICAL DISCONNECT AND MOTOR STARTER (AS REQUIRED) BY ELECTRICAL CONTRACTOR 2 6 -AMP ELECTRONIC VARIABLE SPEED CONTROL, PROVIDED BY MECHANICAL, INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR 3 THERMOSTAT PROVIDED BY MECHANICAL TO BE INSTALLED BY ELECTRICAL 4 FOR TRADE COORDINATION REFER TO APPROVED EQUIPMENT SUBMITTALS 5 INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS 6 FIELD COORDINATE EXACT LOCATION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 992013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 19 2013 PERMIT CENTER ISSUE FOR PERMIT ermanson Hermanson 1221 2nd Kent, Washington Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor ,, xf Company LLP Avenue North 98032 Reg #: HERMACLOO5BJ TUKWILA ELEMENTARY EXHAUST INSTALLATION 5939 S. 149TH ST. TUKWILA, WA 98168 Revisions 08/16/13 MG REVISED PERMIT 07/25/13 MG ISSUE FOR PERMIT No. Date By Description Design Team Design MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0400-02599 Project Number 11-13-02599 Issue Date 07/25/13 1ST FLOOR PLAN, ELEVATION & EQUIPMENT SCHEDULE - HVAC M2.O1