Loading...
HomeMy WebLinkAboutPermit M13-140 - 18200 SEGALE BUILDING - VACANT SPACE ALTERATIONVACANT SPACE 18200 SEGALE PARK DR B M13-140 City oitukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 2061431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3523049119 Address: 18200 SEGALE PARK DR B TUKW Project Name: VACANT SPACE Permit Number: M13-140 Issue Date: 08/15/2013 Permit Expires On: 02/11/2014 Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: JOFFRE SECHIER Address: 3202 C ST NE , AUBURN WA 98002 Email: JOFFRE@COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P-105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 251-9840 Phone: 425-251-9840 Expiration Date: 04/25/2014 DESCRIPTION OF WORK: INSTALL (1) DUCTLESS SPLIT AC SYSTEM WITH (1) INDOOR WALL MOUNT AIR HANDLER TO THE ELEVATOR MECHANICAL ROOM Value of Mechanical: $2,886.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $224.88 International Mechanical Code Edition: 2012 "c/ Date: W6// I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erfo ' • ce of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit I JISSignature: ..1 Date: (/ t. 43 Print Name: irk `L- GLvsza This permit shall become n la d void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. RA1 inn orinro,l• nn_ic_",nig PERMIT CONDITIONS Permit No. M13-140 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. dor.: IMC -4/10 M13-140 - Printed: 08-15-2013 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. • Project No , Date Application Accepte Date Application Expires: (For office use only) • MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: J 'Zd0 �Y Tenant Name: Unenn•b• 1� 2rk Pr i PROPERTY. OWNER•tc.rk---. Name: Pr:. e.512 C. Address: ‘6PZg City: 7''�%ikwIIG' tate: 0A Zip: MS CONTACT PERSON - person receiving all project communication ;; Name: 107T(e, . ecjiK' Address: 320Z. C ✓j . Ne- City: QU L,UGG((i//n State: L^ Zip:OµrytiL Phone: �iU�Z6/ •ft Fax: z63. 3i . /'SgQ' Email: \101;;,e_ �eQyi&/6%'i%I:v I fir% King Co Assessor's Tax No.: 3513616/9 Suite Number: Floor: New Tenant: ❑ Yes ,!..No MECHANICAL CONTRACTOR INFORMATION :':... Company Name: Comp /(GC.��/7 `6 „ lca �' Address: ?Za a 65e/(j4.--- `u/ City4U ff State:: (t /(_ Zip:eiecita, Phone: y26.061. QG // Fax: 7i.3 --z. z 6 78 Contr Reg No.: col F0/41 6LA Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 20g6 Describe the scope of work in detail: 1-n 5'6.0 CI adk_55 ._5; » AC •5)/5-Z,01 Ci) 1Yid oor ()a Moco t Glr herrA r M eilo cc/ 4o M Use: Residential: New Commercial: New ❑ Replacement ., El Replacement ., ❑ Fuel Type: Electric El Gas El Other: H:\Applintious\Forna-Applicatwns On Linc\201 I Applications\Mechatucal Puma Application Revised 1-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfrn . Unit Type _ Qty. Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator —. domestic Incinerator — comm/industrial Unit Type Qty= Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty= 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu • PERMIT APPLICATION NOTES Value of construction-,in,all cases, i value of construction amount should be entered by the applicant. Thikfigure will'be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. .. - tI xpiration of plan review — applications for which no permit is issued within 180 days following the 'date of application shall expire by limitation. .. - 'he building officiafmay grant one extension of time'for additional periods not to exceed 90 days each. The extension shall lbe.requested in• writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY ,THAT HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O jor' ' 111'RIZED AGENT: Signature: Print Na j(474h /S Mailing Address: 3207 C 56/16— Day Telephone: • Date: H:\Applicatious\Forms-Applications On Linc1201 I Applications \Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh City e61:leifx) x,11 ' 9•5602_ State 'Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY I PAID M13-140 Address: 18200 SEGALE PARK DR B Apn: 3523049119 MECHANICAL PERMIT FEE PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1290 R000.322.100.00.00 R000.322.102.00.00 $196.31 $196.31 $196.31 $157.05 $39.26 $196.31 Date Paid: Thursday, February 20, 2014 Paid By: JESSE CHUTICH COMFOPRT MECHANI Pay Method: CREDIT CARD 210203 Printed: Thursday, February 20, 2014 10:30 AM 1 of 1 CRWYSTEMS i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Eov RECEIPT Parcel No.: 3523049119 Permit Number: M13-140 Address: 18200 SEGALE PARK DR B TUKW Status: PENDING Suite No: Applied Date: 08/07/2013 Applicant: VACANT SPACE Issue Date: Receipt No.: R13-02307 Initials: User ID: JEM 1165 Payment Amount: $224.88 Payment Date: 08/07/2013 10:24 AM Balance: $0.00 Payee: COMFORT MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 17618 224.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 179.90 000.345.830 44.98 Total: $224.88 rinr• RCrAlnt-na Printed: 08-07-2013 INSPECTION RECORD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila.. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 w"13-1gC Nsl UR Project: �A Le Type ofns _ection: t- f NM (,__,, Adrgss c it Y i 6 lite atstd: t`a.m p:mSpecial Instructions: Date Want dc‘ 1.-1 ,---7Li — I 4 Requester: Phone No: Approved per applicable codes. C' Corrections required prior to approval. COMMENTS: n pector: REINS//PECTION FEE REUIRED. Prior to , ext inspection, fee must be paid -di 6300 SouthcentetBlvd.. Suite 100 Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila.. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: UJ C A s c9 A C� �~ Type of Inspection: rZt l.1n -- �. N Address: 1932_00 spI' P>tb2 Date Called: B Special Instructions:. Date Wa _ted: "'--I 1 �--( a.ta.. �* -, Requester: t7OA(cP Phone N//o: q ®Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pevqh Inspe o Date: El SPECTION FEE REQUIRED. 'rior to neinspection, fee must be a' at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. RACKS M 1- Mb FILE COPY Permit No. c)0 \ \ P) REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION 36 8808 ElAVIMit R4OtA CA.t, Wow s� A , RECEIVED CITY OF TUKWILA JAN 3 0 2014 PERMIT CENTER 1 Ca? � �' `(P2, kam cJ n tj M r n9-88 ZHOIHH S:\Facilities\Segale Business Park\763\Proposals\Seattle Gourmood\763 Seattle Gourmet Food.dwg,1/21/2014 1:43:10 PM L5'GREENHECK Building Value in Air. Printed Date: 1/22/2014 Job: Comfort Mechanical Mark: G -123 -VG Model: G -123 -VG Direct Drive Centrifugal Roof Exhaust Fan Dimensional Quantity 1 Weight w/o Acc's (Ib) 45 Weight w/ Acc's (Ib) 67 Optional Damper (in.) 12 x 12 Roof Opening (in.) 14.5 x 14.5 Performance Requested Volume (CFM) 1,300 Actual Volume (CFM) 1,300 External SP (in. wg) 0.25 Total SP (in. wg) 0.25 Fan RPM 1203 Operating Power (hp) 0.16 Elevation (ft) 30 Airstream Temp.(F) 70 Air Density (ft3) 0.075 Tip Speed (ft/min) 4,115 Static Eff. (%) 33 Motor Motor Mounted Yes Size (hp) 1/2 V/C/P . 115/60/1 Enclosure ODP Motor RPM 1725 Windings 1 FLA (Amps) 6.2 Sound Power by Octave Band 1.0 0.8 0. a) to ID 0.4 24.38 23 75 4.38 19 Reference assembly view drawings for actual dimensions with mounted accessories 'Overall height may be greater depending on motor 1.75 - 0.0 A U • 0 3 6 Volume Operating Bhp point Operating point at Total SP Operating point at External SP Fan curve - System curve Brake horsepower curve Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Data Inlet 69 73 74 68 61 59 54 53 70 59 9.4 CAPS 4.13.1242 Notes: All dimensions shown are in units of in.. 'FLA - based on tables 150 or 148 of National Electrical Code 2002 Actual motor FLA may vary, for sizing thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI SI.4 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per Octave band at 5.0 ft - dBA levels are not licensed by AMCA International Sones - calculated using AMCA 301 at 5.0 ft 9 100 12 15 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION Z:\Matt\wincaps\Jobs\Comfort Mechanical.gfcj 7 • mca CERTIFIED RRTlncf %sounn v rrvocm c R mn fm[nr °b n n°Cnnmoi mmcmnnn martnnnonm. Inc Page 1 of 5 GREENHECK Building Value in Air. Printed Date: 1/22/2014 Job: Comfort Mechanical Mark: G -123 -VG Model: G -123 -VG Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined wheel - Aluminum curb cap with - prepunched mounting holes - Birdscreen - Ball bearing motors (sizes 100-180), sleeve bearing motors (sizes 60-95) - Motor isolated on shock mounts - Corrosion resistant fasteners. Options & Accessories: Motor - Vari-Green EC motor w/Mounted Potentiometer Dial UUcUL 705 Listed -"Power Ventilators" Switch, NEMA -1, Toggle, Junction Box Mounted & Wired Roof Curb-Galv., GPI -19-G12, Under Sized 1.5 in. Total Damper, WD -100 -PB -12X12, Gravity Operated (Loose), Not Coated Unit Warranty: 1 Yr (Standard) CAPS 4.13.1242 Z:\Matt\wincaps\Jobs\Comfort Mechanicat.gfcj REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION Page 2of5 GREENHECK Building Value in Air. Printed Date: 1/22/2014 Job: Comfort Mechanical Mark: G -123 -VG Vari-Green Motor & Control Options An EC motor that uses AC input power and internally converts it to DC power. Potentiometer (dial) mounted on the motor enclosure adjusts the speed (RPM) down 80%. Motor Type: Dial on Motor Wiring Diagram I I SPEED CONTROL O - v + 0 VARI ��a^REMEEN. I I CAPS 4.13.1242 Z:\Matt\wincaps\Jobs\Comfort Mechanical.gfcj POWER INPUT BLACK 115 VAC WHITE NEUTRAL GREEN GROUND REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 • City of Tukwila BUILDING DIVISION Page 3 of 5 GREENHECK Building Value in Air. Printed Date: 1/22/2014 Job: Comfort Mechanical Mark: G -123 -VG Horizontal Mount Exhaust Damper Model: WD -100 Standard Construction Features: - Model WD -100 is a horizontal mount exhaust damper (air flow up) and is constructed of 18 ga galvanized steel with pre - punched mounting holes - Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening - Steel axles are 0.188 in. diameter zinc plated mounted in acetal bushings - Synthetic axle bearings 12 i 12 • DAMPER L�SPfPPP�s TYP. SECTION VIEW Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.125 in. undersize CAPS 4.13.1242 Z:\Matt\wincaps\Jobs\Comfort Mechanical.gfcj REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION Page 4 of 5 GREENHECK Building Value in Air. Printed Date: 1/22/2014 Job: Comfort Mechanical 1.75 Actual L Ac ual W GPI Roof Curb STANIDARD CONSTRUCTION FEATURES • Welded Aluminum (0.064 in.) or galvanized (18 ga) construction • Straight sided • 2 in. roof mounting flange • 1 in. 3# density insulation • Wood nailer. Roof Opening - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. With dampers, e.ght the Minimum roof opening dimension should be at least 2.5 in. more than the damper dimension. NOTES: * The Roof Opening Dimension may NOT be the Structural Opening Dimension. * Maximum single piece shipping length is 76". * Security Bars are optional and must be specified. Frames and gridwork are all 10 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. To prevent corrosion, they are coated with Greenheck's high performance Permatector coating. • Flange W e NOTES: All dimensions shown are in units of inches Mark Qty. Cap WxL Actual WxL Flange WxL Height Damper Tray • WxL G -123 -VG 1 19 x 19 17.5 x 17.5 21.5 x 21.5 12 CAPS 4.13.1242 Z:\Matt\wincaps\Jobs\Comfort Mechanical.gfcj REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION Page 5 of 5 • anasonic ])r. f Split System Submittal Data Indoor: CS-E12NKUAW Outdoor: CU-E12NKUA Wall Mounted Heat Pump Job Name: Location: Engineer: Submitted to: Submitted by: Reference: Power Circuit Ampacity Fuse Size, Max. Compressor No. used Output Power Outdoor Unit Fan type Motor Type Output Power Airflow Coil Type Fin Type - Pipe Type Rows - F.P.I Face Area Indoor Unit Fan type No. Speeds V/PH/Hz (A) (A) CFM (sq.ft) RPM (High) Motor Output (VV) CFM (QIo,Lo,Me,Hi,Shi) Indoor Sound Rating (Hi) (dB -A) Coil Type Fin Type - Pipe Type Rows - F.P.I Face Area Drain Connection Size (sq.ft) (in.) 230/208/1/60 15 15 DC Rotary Inverter 1 700 Propeller DC Motor ( 8 poles ) 40 1095 Aluminum ( Blue Coated ) Corrugated Fin 2-17 2.8 Cross Flow 5 1300 40 187/246/335/425/472 40 Aluminum Fin & Copper Tube Slit Plate - Inner Rifled 2-19 2 5/8" Features Wireless Remote Controller Standard Wired Remote Controller ( CZ-RD516C ) Optional Controls Remote Controller Temperature Control Air Louver (Horizontal) (Vertical) Power Failure Automatic Restart Self -Diagnosis Air Filter LCD Wireless Type, Microprocessor Temp, Sensor Built In IC Thermostat Manual Automatic Built -In Built -In Washable, Anti -Mold ."4-111.2 cort Approval: Date: Construction: Unit #: Drawing #: Refrigerant Lbs. - R410a (o Control Connection Line Length, Max (ft.) Lift Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) Flare 66 49 1/4" 1/2" Dimensions (in.) Height Width Depth Indoor Unit (Uncrated) 11-7/16" 34-9/32" 8-1/16" (Crated) Outdoor Unit (Uncrated) 21-9/32" 30-23/32" 11-13/32" (Crated) Weight Net Shipping (lbs.) (lbs.) Indoor Outdoor 20 82 Performance Data © ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (Wj Outdoor Sound Rating (dB -A) Heating Total Capacity HSPF Amps Power Inputs Outdoor Sound Rating Operating Range (BTU/H) (A) (dB -A) Indoor Air Intake Temp. Cooling Maximum 90F DB/74F WB Minimum 60F DB/52F WB Heating Maximum 86F DB/ -F WB Minimum 60F DB/ -F WB 10200 21 2.5 3.5 650 47 14100 10.5 6.1 1150 46 Outdoor Air Intake Temp. 115F DB OF DB 75F DB/ 64F WB 5F DB/ -F WB RECEIVED CITY OF TUKWILA AUG 0 7 2013 M\ PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 ` 2013 utdoorunQt.ILDING City of Tukwila DIVISION . R410A 2.16 Flare 66 49 1/4" 1/2" Dimensions (in.) Height Width Depth Indoor Unit (Uncrated) 11-7/16" 34-9/32" 8-1/16" (Crated) Outdoor Unit (Uncrated) 21-9/32" 30-23/32" 11-13/32" (Crated) Weight Net Shipping (lbs.) (lbs.) Indoor Outdoor 20 82 Performance Data © ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (Wj Outdoor Sound Rating (dB -A) Heating Total Capacity HSPF Amps Power Inputs Outdoor Sound Rating Operating Range (BTU/H) (A) (dB -A) Indoor Air Intake Temp. Cooling Maximum 90F DB/74F WB Minimum 60F DB/52F WB Heating Maximum 86F DB/ -F WB Minimum 60F DB/ -F WB 10200 21 2.5 3.5 650 47 14100 10.5 6.1 1150 46 Outdoor Air Intake Temp. 115F DB OF DB 75F DB/ 64F WB 5F DB/ -F WB RECEIVED CITY OF TUKWILA AUG 0 7 2013 M\ PERMIT CENTER Indoor Dimensions <Too Views <From View. Bottom View', 2-318T1 4-7/8 (1-5/8 '-'2:3/8) Rear Vies/. ts-in3 4-112 _ ...,_,.., •,...... . . ---......2iumaia.•...- PO ___________ ii irr: till II l""lilli"Irillridr- - .- nemommismn. 11=2:=1rr,"........."„„„ ,,,... , , ...•.....•...... .......•.• Gas side Uquid side <SIMI Vies.. <Remote Conoco. 1-7/8 ng Outdoor Dimensions Space necessary for Installation 0,f,1 r 3-718 3-7/8 •?:?,1 38-3/8 Anchor Boll Pitch 12-518 x 22-1/2 <Side View EBB rn cpm mum Es oar oo man. mop I Unit. inch] <Top View> 2 -way valve's! Liquid 'side (High Pressure) 3 -way valve at Gas side (Low Pressure) <Sido View. 11-13/32 1/2/2014 • • City of Tukwila Department of Community Development JOFFRE SECHIER 3202 C ST NE AUBURN, WA 98002 RE: Permit No. M13-140 VACANT SPACE 18200 SEGALE PARK DR B Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the.above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/11/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the.inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/11/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, v1 Jenn fer Marshall Per it Technician File too: M13-140 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT CORD COPY• PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-140 PROJECT NAME: VACANT SPACE DATE: 01/30/2014 SITE ADDRESS: 18200 SEGALE PARK DR B Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: �S ?4Otk1 Building Division Fire Prevention Public Works n Structural. Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable Ti (no approval/review required) DATE: 02/04/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/04/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 AO PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-140 DATE: 08/07/13 PROJECT NAME: VACANT SPACE SITE ADDRESS: 18200 SEGALE PARK DR B X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: pt, c 4-01. 3 Building Division Public Works Att4 &I/A— Oil3 Fire Prevention Planning Division Structural E ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 08/08/13 Not Applicable ❑ Comments: Permits Center Use Only INCOMPLETE LETTER MAILED: LEiTTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg El Fire 0 Ping El PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/05/13 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: PROJECT NAME: \I • eoc.Q,, PERMIT NO:• ' l i �j — 9 0 SITE ADDRESS: V3 )-0 6 S-ec4,14 a -t€ 3 ORIGINAL ISSUE DATE: g REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS I l-30 LJ E g—)-0-1-14 vA2 Summary of Revision: a %,,,,t..,V.01,4_0'f-- Ste b-11-oov � _ Azd-- `tL►A Avtt A4A saeint (air-- jvt+ f -c) Yo -o11' \ re Li --1-019 wtc Received by: Jacc e C A ,41i -t- f REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • I City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 01/30/2014 Plan Check/Permit Number: M13440 Response to Incomplete Letter # Response to Correction Letter # Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Vacant Space Project Address: 18200 Segale Park Dr B Contact Person: Joffre Sechier Phone Number: (425) 251-9840 Summary of Revision: INSTALL (I) 1200 CFM ROOF MOUNTED BATHROOM EXHAUST FAN WITH DUCTING TO (2) NEW BATHROOMS. INSTALL (2) SUPPLY AIR DUCT RUNS INTO NEW BATHROOMS FROM EXISTING HVAC UNIT. ""r`/ Or 'IAN 3 0 2014 PEAMIrcENTEil Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on II \Applications\Forms-Applications On Line \2010 Applications \7-2010 - Revision Submittal.doc Revised: May 2011 Contractors or Tradespeople Per Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL UBI No. 601954041 INC Phone 4252519840 Status Active Address 3202 C St Ne License No. COMFOMI015LA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 6/1/1999 State WA Expiration 4/25/2014 Date Zip 98002 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM"010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/1999 5/1/2014 Active COMFOP*064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/20065/24/2008 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Bond Amount JACKSON, HERB J Vice President 01/01/1980 9815017 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Lexon Ins Co 9815017 06/01/2012 Until Cancelled $6,000.00 06/04/2012 2 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/2002 Until Cancelled 06/01/2012 $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Federated Mutual Ins Co 9849307 06/01/2010 06/01/2014 $1,000,000.00 05/20/2013 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/15/2013 PARCEL Parcel Number Name Site Address Legal 352304-9119 SEGALE PROPERTIES LLC 18125 ANDOVER PARK W PAR A OF TUKWILA BLA #L02-029 REC #20021007900001 D PAR LOCATED E 1/2 & SW 1/4 OF SD SEC BUILDI Year Built 1979 Building Net Square Footage 25962 Construction Class MASONRY Building Quality AVERAGE/GOOD Lot Size 1490290 Present Use Warehouse Views N Waterfront CU -1 ASSESSOR DATA 13 SITE PUN BUILDING 763 NORTH LEASE SPACE. NEW ELEVATOR AND RESTROOMS. SEE ENLARGED PLANS FOR ALL WORK. SITE PLAN VICINITY MAP 02013 MapQuest - Portions 02013 N*VTEQ j e s PROJECT DESCRIPTION: 1.INSTALL (1) DUCTLESS SPLIT AC SYSTEM, WITH (1) INDOOR WALL MOUNT AIR HANDLER TO THE ELEVATOR MECHANICAL ROOM GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 & R3.3 Revised June 2013 Project Info Project Address VACANT SPACE Date 8/6/2013 18200 SEGALE PARK DR B TUKWILA, WA 98188 Applicant Name: JOFFRE SECHIER Applicant Address: 3202 C ST NE, AUBURN, WA 98002 Applicant Phone: 426-261-9840 For Building Dept. Use Project Description Briefly describe mechanical system type and features. ❑ Includes Plans INSTALL (1) 1 -TON DUCTLESS SPLIT AC SYSTEM, WITH (1) INDOOR WALL MOUNT AIR HANDLER TO THE ELEVATOR MECHANICAL ROOM. Induce documentation requiring compliance with commissioning requirements, Section C408 Compliance Option QQ 'Simple System 0 Complex System Q System Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipmen schedules on the plans. For projects without plans, fill in the required information below 3.7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 4. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 5. INSTALL RETURN AIR DUCT SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM. 6. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 7. PROVIDE AIR BALANCE AND COMMISIONING REPORT, 8. PROVIDE O&M MANUALS WITH STAFF TRAINING. 9. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 10. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 11. INSULATE ALL DUCT PER WSEC TABLE 14-5. 12. SEAL ALL DUCT PER WSEC. HVAC Equipment Schedule REVIEWED FOR CODE COMPLIANCE APPROVED AUG 12 2013 tL /1/- City of BUILDING ,' VISION Ductless Split System Label Brand Model Ton CFM OSA CFM Econo. SP Cap. Cool SEER Btuh-In Btuh-Out HSPF Weight CU -1 PANASONIC CU-E12NKUA 1 0 0 N/A 0.5 10,200 21 0 0 10.5 82 AH -1 PANASONIC CS-E12NKUAW 1 350 0 N/A 0.5 . 10,200 N/A 0 0 0 20 SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping ►`1 r ►1 City of Tukwila BUILD?NG DIVISION (N) CU -1 INSTALL ONTO ROOFTOP REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PARTIAL ROOF PLAN MEZZANINE OFFICE AREA rn V.V • 1 • -. Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h PANASONIC CU-Si2NKUA 10200 AH -1 PANASONIC CS -E .2NK[JAN 10200 OSA CFM or Econo? N/A N/A SEER or EER Econmizer IPLV3 Option or Exception N/A N/A 21 N/A N/A Heat Recovery Y/N N Heating Equipment Schedule Equip. Equip ID Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency's Heat Recovery Y/N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP1 HP/BHP Flow Controls Location of Service Service Water Heating Equi-,ment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub - Category EFr Location of Service ' If available. 2 As tested according to Table C403'2.3(1)A thru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). Economizer exception number per Simple Systems C403.3.1 or Complex Systems 0403.4.1. 7 Efficiency Factor per Table C404.2 [ �F»E COPY permitj � 0 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize th ,lo!ation of any adopted code or ordinance. Receipt of approved ' Id Copy and cam Isacknowledged:. By Date V PCZ.--1S-i3 city Of Tukwila BUILDING DIVISION ELEVATOR MECH. ROOM L. PARTIAL FLOOR PLAN • LI EXIT • WARFHnUSE MEN m WAREHOUSE WOMEN CMIZI.. t (N) AH -1 INSTALL ONTO WALL - I RECEIVED CITY OF TUKWILA AUG 072013 PERMIT CENTER HVAC SERVICE AND coNSiWJCT10N 3202CSTNE AUBURN, WA 98002 425.251.9840 F. 253.736.6598 SEGALE PROPERITES VACANT SPACE 18200 SEGALE PARK DR B TUKWILA, WA 98188 rssin...A DATE; SCALE, DRAWN: CHECKED, M l 00-000 NI 1