Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-153 - TREK BICYCLES - REPLACE ROOF TOP UNIT
TREK BICYCLES 331 TUKWILA PY M13-153 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 0223000010 331 TUKWILA PY TUKW Project Name: TREK BICYCLES Permit Number: M13-153 Issue Date: 10/03/2013 Permit Expires On: 04/01/2014 Owner: Name: Address: Contact Person: Name: Address: Email: BETA HOLDINGS LTD 18827 BOTHELL WAY NE , BOTHELL WA 98011 NICK HAWKINS 5822 WERNER RD , BRENERTON WA 98312 NICKH.AMS @C OMCAST.NET Contractor: Name: AIR MANAGEMENT SOLUTIONS LLC Address: 5822 WERNER RD , BREMERTON WA 98312 Contractor License No: AIRMAMS952QM Phone: 360-536-3692 Phone: 360-479-6500 Expiration Date: 11/14/2013 DESCRIPTION OF WORK: CHANGE OUT ROOFTOP HVAC UNIT. SEE ATTACHED DETAILED SCOPE. Value of Mechanical: $6,950.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie oNA Fees Collected: $274.13 International Mechanical Code Edition: 2012 Date: ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or the performance of work back of this permit. Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating • am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: `O /1/p This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. RA11 1A•1 Printarl• PERMIT CONDITIONS Permit No. M13-153 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code'or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. dnr.• IMC. -4/1n M13-153 Printed: 10-03-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. V(f 3 ) Project No. Date Application Accepted: B-22%-- 13 Date Application Expires: (21 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 022300-0010 Site Address: 331 Tukwila Pakway Suite Number: Ground New Tenant: Tenant Name: Trek Bikes PROPERTY OWNER Name: Nick Hawkins Name: Beta Commercial Properties City: Bremerton State: WA Zip: 98312 Address: 18827 Bothell Way NE Email: nickh.ams@comcast.net City: Bothell State: wa Zip: 98011 CONTACT PERSON — person receiving all project communication Name: Nick Hawkins Address: 5822 Werner Road City: Bremerton State: WA Zip: 98312 Phone: (360) 536-3692 Fax: (360) 479-6506 Email: nickh.ams@comcast.net Floor: ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: Air Management Solutions Address: 5822 Werner Road City: Bremerton State: WA Zip: 98312 Phone: (360) 479-6500 Fax: (360) 479-6506 Contr Reg No.: AIRMAMS952QM Exp Date: `x/R1I3 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 6,950 Describe the scope of work in detail: Changing out rooftop HVAC unit. See attached detailed scope. Use: Residential: New ❑ Replacement ❑ Commercial: New El Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I .docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN& OR AUTHORIZED AGENT: Signature: v Date: 08/25/2013 Print Name: Nick Hawkins Day Telephone: (360) 536-3692 Mailing Address: 5822 Werner Rd Bremerton WA 98312 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 Lclocx Revised: August 2011 bh Page 2 of 2 1 A City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0223000010 Permit Number: M13-153 Address: 331 TUKWILA PY TUKW Status: PENDING Suite No: Applied Date: 08/27/2013 Applicant: TREK BICYCLES Issue Date: Receipt No.: R13-02482 Initials: User ID: WER 1655 Payment Amount: $274.13 Payment Date: 08/27/2013 11:52 AM Balance: $0.00 Payee: AIR MANAGEMENT SOLUTIONS LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11466 274.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 219.30 000.345.830 54.83 Total: $274.13 a Rcrcint_rIR Printed• OS -27-2013 INSPECTION RECORD Retain a copy with permit C INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it/ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 A4 3 -i s Projezt/~'�/w n STD Typ tS f Insp ction: 1 Address: I � � \� _3I o Date Called: �- ,/ 'a,m.. p.m. _ Special Instructions: i A - Date Wanted:: /,/ i �"l f " /� 'j%�' Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: i)efM, ( MP (e A- nspectpr: Date: / REINSPECTION FEE REQUIRE . Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. air INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 fir3-/S" Project: 6; a Type on: ,O eat r '"'-^'l ri A-) Address:� �U � _,).K G.D ,--42c.„,,,,, L.Ae _'-. ( ,A 7- g)' Date Called: Special Instructions: .0-77 K l 4 Date Wanted: 7 _ 1 ilequester: 0A Phomac0„D s1' -3t0 i 2_ DApproved per applicable codes. EjCorrections required prior to approval. COMMENTS: ,O r J 644— .LN --- c� p f --,,,-- __ _,).K G.D ,--42c.„,,,,, L.Ae _'-. ( ,A 7- g)' %e__,S J (P r' 1 . I I REINSPECTION FEE REQ IPrior to next inspection, fee must be paid at 6300 Southcenter 8tv;., Suite 100. Call to schedule reinspection. 0 9 n C' 01 0 f) �.r • U ft Ltz- D C ,14 [i 0 Ard1 -'vi i.owfir ,F.J+ ,. r fir! (11 Paffilltloo Pier rrliaw approval is subject ®SPS and © aSiORS. •r. of construction documents doss not author 29 ti adopted c' a or ordinance. Raccipt Lr: r oval Field Copy8.11Cd ardar Cis is nc nionflsdged: By Ogg • 43 oil k RECEIVED CITY OF TUKWILA AUG 2 7 209 PERMIT CENTER I TRANE® FILE COPY TAG: PRODUCT MODEL RATED Volts/Ph/Hz Performance (COOLING) O BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating (dB(A) SPECIFICATIONS 4WHC3036A1000A 208-230/1/60 35600 1200 3.24 11 / 13 75 Performance (HEATING) C) (High Temp.) BTUH - C.O.P. Power Input (KW) (Low Temp.) BTUH - C.O.P. Power Input (KW) HSPF (BTU /Watt -Hr.) POWER CONN.—V/Ph/Hz Brch. Cir. Ampacity ® Fuse Size—Max. (amps) Fuse Size—Recmd. (Amps) COMPRESSOR No. Used—No. Speeds Volts/Ph/Hz R.L. Amps—L.R. Amps 36600 - 3.7 2.9 20200 - 2.48 2.39 8 208-230/1/60 22 35 35 RECIP 1-1 208-230/1/60 13.2 - 71.8 OUTDOOR COIL—TYPE Rows/FPI. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control PLATE FIN 2/22 11.2 3/8 TXV-NB INDOOR COIL—TYPE Rows/FPI. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) Duct Connections PLATE FIN 4/12 3.44 3/8 TXV-NB 3/4 FEMALE PVC SEE OUTLINE DRAWING OUTDOOR FAN —TYPE No. Used/Dia. (in.) Type Drive/No. Speeds CFM @ 0.0 in. w.g. No. Motors—HP Motor Speed R.P.M. Volts/Ph/Hz F.L. Amps—L.R. Amps PROPELLER 1/20 DIRECT / 1 2500 1-1/5 850 208-230/1/60 1.0 - 2.2 INDOOR FAN—TYPE Dia x Width (in.) No. Used Drive / Speeds (No.) CFM vs. in. w.g. ® No. Motors—HP Motor Speed R.P.M. Volts/Ph/Hz F.L. Amps CEN fRIFUGAL 10 X 10 1 DIRECT / 2 SEE FAN PERF TABLE 1 - 0.5 1050 208-230/1/60 4.1 FILTER / FURNISHED Type Recommended Min. Face Area ® NO THROWAWAY 4.00 REFRIGERANT Charge (lbs. of R -410A) 9.2 lbs DIMENSIONS Crated (in.) Uncrated HXWXD 36 X 33-3/4 X 48 SEE OUTLINE DRAWING WEIGHT Shipping (lbs.) Net (lbs.) © 2009 Trane 345 298 4WHC3036A-SUB-1 3 Ton Horizontal Packaged Heat Pump 4WHC3036A1000A ®Certified in accordance with the Unitary Air -Conditioner Equipment certification program, which is based on AHRI Standard 210/240. ® Sound Power values are not adjusted for AHRI 270-95 tonal corrections. ® Calculated in accordance with currently prevailing Nall Electrical Code. ® Standard Air — Dry Coil — Outdoor. Standard Air — Wet Coil — Indoor. © Rated in accordance with D.O.E. test procedure. 0 Filters must be installed in return air system. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recom- mendations with clean resistance of 0.05' W.C. teb&) L) + REVIEWED FOR CODE COMPLIANCE APPROVED SEP 17 2013 City of Tukwila BUILDING DIVISION MIL3-153 RECEIVED CITY OF TUKWILA AUG 2 7 2013 PERMIT CENTER Dimensional Data and Weights CONDENSER COIL 33mm C 1.5/16 I DRAIN HOLE —REFRIGERANT GUAGE CONNECTIONS INDOOR BLOWER ACCESS RAIN PAN CONNECTION 19nm C 3/4 'I FEMALE NPT 803mm 1 31-5/8 1 772mm [ 30-3/8 1 III8mm I 44 1 260mm I Imm 110-1/41 (6 3/41 102mm (4 CONDENSER COIL 1.375 DIA. K.O. FOR SUPPLEMENTARY HEATER N.V. POWER ENTRY 0.875 DIA HOLE 0 1.375 DIA K.O. FOR H.V. POWER ENTRY 0.875 DIA HOLE FOR L.V. POWER ENTRY ONTROL BOX ACCESS MODEL APPROX. CORNER WEIGHT - KG(LBS) TOTAL WEIGHT KG(LBS) COIL DIMENSION -mm (in) Wt W2 W3 W4 A B 4WHC 3024 47 (103) 30 (66) 30 (66) 29 (63) 135 (298) 356 (14) 406 (16) 4WHC3030 47 (103) 30 (66) 30 (66) 29 (63) 135 (298) 356 (14) 406 (16) 4WHC3036 47 (103) 30 (66) 30 (66) 29 (63) 135 (298) 356 (14) 406 (16) 4WHC3042 39 (87) 37 (81) 30 (66) 33 (72) 139 (306) 508 (20) 406 (16) 2 Unit Performance Data 4WHC3036 Indoor Blower Performance MOTOR SPEED RATED VOLTAGE EXTERNAL STATIC PRESSURE (IN. WG) 0.2 0.3 0.4 0.5 O LOW WATTS 325 330 340 350 CFM 1205 1160 1115 1075 HIGH WATTS 410 415 410 395 CFM 1325 1275 1215 1150 �I - WET COIL, NO FILTERS - FACTORY SETTING Supplementary Electric Heater Data Supplementary Electric Heaters D675039 HEATER MODEL RATED VOLTAGE PHASE AMPS KW BAYHTRC106A 208/240 1 20.8/24 4.33/5.76 BAYHTRC109A 208/240 1 6.12/8.16 BAYHTRC111A 208/240 1 38.1/44 7.93/10.56 BAYHTRC117A 208/240 1 62.4/72 12.98/17.28 3 Mechanical Specifications General All units are factory assembled, piped, internally wired and fully charged with R -410A. Units are certified to UL Standard 1995. All units are factory run -tested to check cooling and heating operation, defrost operation, fan and blower rotation and control sequence. Units shall be designed to operate at ambient tempera- tures between 5°F and 45°F in cooling mode (as shipped) and between 75°F and -20°F in heating mode. Cooling and heating performances are rated in accordance with AHRI standards. Units are designed for either rooftop or ground level installation. All units shall be dedicated horizontal airflow and are not convertible. Unit Casing All components are mounted in a weather -resistant steel cabi- net with a baked -on enamel finish. Access panels are provided for unit controls, indoor coil and supply air fan. Top covers shall be removable for access or installation of electric heaters and outdoor fan and compressor. Indoor air section is completely insulated with fireproof, permanent, odorless glass fiber mate- rial. Knockouts are provided for utility and control connections. Drain connections are provided to accommodate indoor coil water runoff. Compressor Hermetically sealed, high efficiency Climatuff® compressor de- signed for heat pump duty. Internal over current and over tem- perature protection, low pressure protection. Refrigerant Circuit All units have thermostatic expansion valve refrigerant control for heating and cooling operation. Service pressure tap ports, check valves, solenoid -operated reversing valve, and refrigerant line filter driers are standard. Trane 6300 Troup Hwy. Tyler, TX 75702 www.trane.com Indoor and Outdoor Coil Indoor and outdoor coils are constructed of aluminum plate fins mechanically bonded to 0.375 -inch seamless copper tubing. Outdoor Fan One, direct -drive, statically and dynamically balanced propeller fan is used in a top discharge configuration. Permanently lubricat- ed weatherproof motors have built-in thermal overload protection. Indoor Fan Forward -curved, centrifugal -type fan with multispeed, direct -drive motor. Motor shall be permanently lubricated and has built-in overload protection. Demand Defrost Control Microcomputer logic is used to sense the need for defrost and permits defrost cycles only when coil icing conditions begin to cause serious heat pump capacity reductions. Accessories Supplemental Electric Heater -Heater module shall mount in unit discharge air passage. Each heater assembly includes automati- cally resetting heat limit switches for thermal protection. A polar- ized plug provides connection to unit low voltage control wiring. Indoor Thermostat -Two-stage heating, one -stage cooling thermostat is available in either manual or automatic changeover. Thermostat provides automatic or continuous fan operation and includes outdoor thermistor, emergency heat switch with indicator light, and auxiliary heat indicator light. Low Ambient Control Kit -Provides low ambient cooling opera- tion to 0°F. 4 Business License Fee Information The license fee is a combination of the business license fee and the revenue generating regulatory license (RGRL) fee. The license fee is based on the number of employee hours on the four quarterly reports submitted to the Washington State Department of Labor and Industries (L&I) from the previous year. The work figure used by L&l is 1,920 hours per year for a full-time employee. In addition to the annual employee hours reported on the L&I report, you must include employee hours for sole proprietors, owners, managers, partners and any officers, agents or personal representatives acting in a fiduciary capacity. It is the responsibility of the employer to determine the number of hours worked within the city. Enter the number of employee hours worked on Line "A". Multiply (Line "A") the total number of employee hours worked in Tukwila by $.034896 to determine the total amount due (Line "B"). The minimum fee for any license is $67.00, which covers 1,920 hours worked in Tukwila. If the amount calculated is less than $67.00 enter $67.00 on Line 3. If the amount calculated is greater than $67.00, enter the greater amount on Line "C". Employers without a full year history would need to estimate the number of employee hours that will be worked in the 12 month period. Outside Contractors or Consultants - Only report those hours worked in Tukwila for the current year, January — December. DLA TRANE' FILLS COPY BTC -SQ -100.00 Packaged Air Conditioners BTCO24-036C D4.I:TA/.,:EUE3MITTAL MODELS: 0 BTCO24C BTC030C O BTC036C VOLTAGES: 0 230/60/1 O 200/230/60/1 0:200/230/660/1 0200/230/60/3 ❑ 460/60/3 Since The Trane Cupparryhasa.policy of continuous product improvement.. it reserves the right to change . ' specifications end n a ithoutnotice. RECEIVED. CITY OF TUKWILA AUG 2 7 2013 PERMIT CENTER 22-1316-1. 1st Printing 1985 Tab 2 The BTCO24-036C units feature: Design Features • ClimatuffTM compressor, hermetically sealed • Compressor crankcase heater • Compressor motor overload protection • Internal pressure relief valve • Copper tube, aluminum plate fin coils • Indoor fan relay • Duct flanges • Top access to supplementary heater and enclosure • Polarized plug for easy field connection of low voltage to supplementary heaters • Heavy -gauge steel cabinet • Weather -resistant baked enamel finish • Quick start kit (BTC030,036C1) • Multispeed, direct -drive blower motor • Low ambient cooling to 55 F as manufactured; to 30 F or 0 F with accessories • Outside pressure taps for refrigerant check • Over (supply) under (return) air configuration • Capillary tube refrigerant control (BTCO24C) • Thermostatic expansion valve control (BTC030,036C) •American Standard. Inc. 1985 Cooling Only Rooftop BTCO24-036C Accessories • Unit mounted electric supplemental heater • Heater enclosure (BTC030,036C) • External electric supplemental heater • Head pressure control for low ambient cooling Ito 0 F (BTC030,036C) • Evaporator defrost control kit for low ambient cooling to 30 F 2 • Thermostats Cooling only with fan switch Heat/Cool with fan switch — horizontal mount Heat/Cool with fan switch — vertical mount Thermostat locking cover Outdoor thermostat 46 to -10 F (adjustable) Table of Contents Model Nomenclature General Data Performance Data Optional Equipment Field Wiring Wiring Diagrams Dimensional Data Mechanical Specifications 3 4 5 10 11 18 24 26 Packaged: Air Conditioners BTCO24-036C Models Available Mainland Tonnage Po*sr Supply BTCO24C100B 2 230/60/1 BTC030C100B 2.5 200/230/60/1 BTC036C1008 3 200/230/60/1 BTC036C300B 3 200/230/60/3 BTC036C400B 3 460/60/3 Model Nomenclature B T C 0 3 0 C T Always "B" Product Type Cooling, Packaged Cooling Capacity (MBh) 024=24MBh 030=30MBh 036=36MBh Major Development Sequence 0 0 B T Minor Design Sequence Secondary Capacity And/Or Factory -Installed Options 00 = Packaged Stock, No Options Unit Voltage 1 = 230/60/1 3 = 200/230/60/3 4 = 460/60/3 General Data Table 1 General Data Model BTCO24C100B BTC030C100B BTC036C100B BTC036C300B BTC036C400B Rated Votts/Ph/Hz 230/1/60 200/230/1/60 200/230/1/60 200/230/3/60 460/3/60 ARI Rating' Net Cooling Capacity 23000 29200 34000 34000 34000 Indoor Airflow (cfm) 800 1000 1200 1200 1200 Power Input (kw) 2.66 3.61 4.07 4.07 4.07 EER/SEER' 8.65/9.50 8.10/9.15 8.35/9.75 8.35/9.75 8.35/9.75 Noise Rating Number2 7.8 8.2 8.2 8.2 8.2 Outdoor Coil — Type Plate Fin Plate Fin Plate Fin Plate Fin , Plate Fin Rows/FPI 3/15 4/15 4/15 4/15 4/15 Face Area (sq. ft.) 5.73 5.73 5.73 5.73 5.73 Tube -Size (in.) 3/8 3/8 3/8 3/8 3/8 Indoor Coil — Type Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Rows/FPI 4/12 4/12 4/12 4/12 4/12 Face Area (sq. ft.) 3.44 3.44 3.44 3.44 3.44 Tube -Size (in.) 3/8 3/8 3/8 3/8 3/8 Refrigerant Control Capillary Tube Expansion Vailve Expansion Valve Expansion Valve Expansion Valve Drain Conn. Size (in.) 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT Outdoor Fan — Type Propeller Propeller Propeller Propeller Propeller No. Used / Dia. (in.) 1 / 20 1 / 20 1 / 20 1 / 20 1 / 20 Type Drive / No. Speeds Direct / 1 Direct / 1 Direct / 1 Direct / 1 Direct / 1 Cfm @ 0.0 in. w.g 2 1700 2300 2300 2300 2300 No. Motors 1 1 1 1 1 Indoor Fan — Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Dia.xWidth(in.) 9x9 10x9 10x9 10x9 10x9 No. Used 1 1 1 1 1 Drive / Speeds (No.) Direct / 2 Direct / 2 Direct / 2 Direct / 2 Direct / 2 No. Motors 1 1 1 1 1 Filter — Furnished No No No No No Type Recommended Hi Vel. — — — — — (No. / Size / Thk.) 1 / 20x20 / 1 in. 1 / 20x25 / 1 in. 1 / 20x30 / 1 in. 1 / 20x30 / 1 in. 1 / 20x30 / 1 in. Refrigerant Charge 5 Lbs. 2 Oz. 7 Lbs. 0 Oz. 7 Lbs. 3 Oz. 7 Lbs. 3 Oz. 7 Lbs. 3 Oz. Dimensions H/W/D H/W/D H/W/D H/W/D H/W/D Crated (in.) 30%/33%/ 46 30%/33% /416 30%/33%/46 30%/33%/ 46 30%/33%/46 Weight Shipping (lbs.) / Net (lbs.) 286 / 270 306 / 290 354 / 338 354 / 338 354 / 338 NOTES: 1. Rated in accordance with ARI Standard 210. 2. Rated in accordance wtih ARI Standard 270. 3. Standard Air - Dry Coil - Outdoor 4. Rated in accordance with DOE test procedure. 4 TRNVE- OPERAT/ON/MA/ Models: BTCO24C100B BTC030C100B BTC036C100B,C300B,C400B Since The Irene Company has a policy of continuous product improvement, it reserves the right to change specifications and design without notice. The installation and servicing of the equipment referred to in this booklet should be done by qualified, experienced technicians. ©American Standard Inc. 1985 BTC -M-4. 22-5312-1 TENANCE GUIDE Single Package Unit. 2, 2-1/2, 3 Ton Library Product Section Product Model Literature Type Sequence Service Literature Unitary Rooftop Air Conditioning BTC Operation /Maintenance 4 Date File No. S 23rrsedes August 1985 SV -UN -RT -BTC -M-4 885 ALWAYS "8" PRODUCT TYPE MODEL NOMENCLATURE TC 030C 1 00 T _ _ _ _ COOLING, PACKAGED COOLING CAPACITY DESIGN SEQUENCE SERVICE DIGIT MINOR DESIGN SEQUENCE SECONDARY CAPACITY AND/OR FACTORY INSTALLED OPTIONS HEAT 00=PACKED STOCK, NO OPTIONS UNIT VOLTAGE. 1 = 230/60/1 3 = 200-230/60/3. 4 = 460/60/3 Operation Unit -operation is controlled by the remote room ther- mostat. Once the thermostat is placed in the "Cool" posi- tion, unit operation is automatic. A fan switch on the thermostat also provides for continu- ous operation of the evaporator fan if desired. This is the "On" position. With the fan switch in the "Auto" position, the fan will operate with the cooling cycle. COOLING On a call for cooling the compressor contactor and evap- orator fan contactor are energized. The contacts of the compressor contactor close and bring on the compressor and the condenser fan motor. At the same time the evap- orator fan contactor closes its contacts to start the evap- orator fan. When the thermostat determines that further cooling is not required the contactors are de -energized. SHORT DURATION SHUTDOWN To shut down the unit for a brief period of time, turn the thermostat system switch to "Off" and place the fan page 2 switch in the "Auto" position. Leave the system discon- nect switch closed to keep the compressor crankcase heat- er energized.. HEATING Accessory electric heaters installed with this equipment would operate off the heating contact of a heating/cooling thermostat. A call for heat will energize a set of sequencers which are timed to close the electrical circuit to each heater at approximately 18 second intervals. However there is an initial 35 seconds before the first contact of each sequence closes. This circuit will not close unless the indoor blower relay has closed. Each heater is protected both by a tem- perature limiting device and separate fuses in each heater bank. This control system eliminates the possibility of all heaters being energized at the same time and therefore reduces the high initial current draw. Maintenance Perform the following inspection and service routine at the beginning of each COOLING SEASON: 1. Clean the condenser coil by hosing with cold water. Do not use hot water. This could cause excessive coil pres- sures. 2. Remove any accumulation of dust and dirt from the unit casing. 3. Clean or replace the air filters. 4. Inspect the control panel wiring to make sure connec- tions are tight and insulation is intact. 5. Inspect the condensate drain pan and condensate pip- ing to make sure they are clear and will carry away all water. MONTHLY INSPECTIONS It is recommended that the following inspections be per- formed once a month. 1. Clean or replace the air filters. 2. Inspect and clean, if necessary, the condensate drain pan and drain connections. 3. Inspect the condenser coil for foreign material. If dirty, clean with a stream of cold water, an air jet or a vacuum cleaner. DO NOT use hot water or steam which can cause high pressures within the refrigerant system. MAINTENANCE PRECAUTION During certain routine maintenance and unit servicing pro- cedures, it will be necessary to open the unit electrical disconnect switch. When this switch is opened, power to the compressor crankcase heater is interrupted. Before operating the unit on a COOLING CYCLE and if the discon- nect switch HAS BEEN OPEN FOR MORE THAN TWO HOURS, do the following as a safeguard against damaging the compressor bearings: 1. Set the thermostat system switch at "Off." 2. Close the unit disconnect switch. 3. Wait 8 hours before resetting the thermostat system switch to "COOL" and operating the unit. SAFETY CONTROLS Internal overload protectors are provided on the condenser and evaporator motors. All units are fully protected against the following abnormal operating conditions: 1. Locked rotor current draw. 2. Sustained high current draw. 3. Excessive heat buildup. 4. High discharge pressure. 5. Loss of refrigerant charge. 6. Excessive cycling on safety controls. The compressors are equipped with a combination winding thermostat/current overload. An internal pressure relief is also provided. An internal winding thermostat senses the temperature of the motor windings. If inadequate cooling causes the wind- ing temperature to exceed this thermostat's setting, the compressor motor is stopped. The thermostat will reset automatically after motor winding temperature falls to a safe level. The reset time will vary from 15 to 45 minutes. Operating on an excessively high suction and discharge pressure differential, an internal pressure relief valve will open allowing discharge gas to pass over the winding ther- mostat. The winding thermostat will sense the presence of hot gas and stop the compressor. The pressure relief valve will reset automatically when the pressure differential is again normal. However, the compressor will not restart until the winding thermostat has cooled sufficiently. page 3 HEAD PRESSURE (PS1G) SUCTION PRESSURE (PSIG1 400 350- 300 250 200 150 100 PRESSURE CURVE — BTCO24C-B INDOOR ENTERING WET BULB •F UPPER CURVE IS 71 F LOWER CURVE IS S9• ■..• Mai IIIIIIUIOUNIIIIIIUIII :in II I IIIIIIIhIII IIIA III I I •..J •..:. .J. • .7• •S• t-1 •••�•••... �:.:••_ ._.INEN •.:.._: _ .-■ - .... • •.ii _:::.P.@�41 p. I. S■ OSP CM iii= • i■ ;0 is 65 75 85 95 105 115 OUTDOOR TEMPERATURE (°F) 1 0 0 INDOOR ENTERING WET BULB •F • 9SFROM TOP DOWN •" - CURVES ARE: 71•F ■ 67•F.63•F 59 F • 90 85 80 75 70 65 60 55 50 • • ■ • • • ■ .J• • OVEN* •.— ■■ •Y it ea • • • • • • • .. 65 75 815r 95 105 115 C135393 Rev. 0 OUTDOOR TEMPERATURE (°F) COOLING PERFORMANCE TO BE CHECKED WHEN OUTDOOR TEMPERATURE IS ABOVE 55°F. AFTER OPERATING PRESSURES HAVE STABILIZED: MEASURE INDOOR WET BULB TEMP. — OUTDOOR TEMP. — HEAD AND SUCTION PRESSURES. LOCATE OUTDOOR TEMP. ® LOCATE INDOOR WET BULB ® FIND INTERSECTION OF OD TEMP. & ID W.B. ® READ HEAD OR SUCTION PRESSURE IN LEFT- HAND COLUMN ® (SELECT PROPER INDOOR CFM) ACTUAL HEAD PRESSURE SHOULD BE ± 10 PSIG OF CHART SUCTION PRESSURE SHOULD BE ± 3 PSIG OF CHART EXAMPLE: ® OUTDOOR TEMP. 85°F., ® INDOOR WET BULB 67°F., ® HEAD PRESSURE @ 800 CFM – 230 PSIG ® ® SUCTION PRESSURE @ 800 CFM – 80 PSIG ® page 4 HEAD PRESSURE (PSIG) SUCTION PRESSURE (PS1G) 400 350 300 250 200 150 100 100 95 90 85 80 75 70 65 60 55 50 PRESSURE CURVE — BTC030C-B INDOOR ENTERING WET BULB •F UPPER CURVE IS 71 F LOWER CURVE IS 59• 65 75 85 95 105 II OUTDOOR TEMPERATURE ( °F) INDOOR ENTERING WET BULB •F FRO1.1 TOP GOWN CURVES ARE: 7 F G7•F, 63•F 59 F 65 5 85 95 105 II OUTDOOR TEMPERATURE (°F) COOLING PERFORMANCE TO BE CHECKED WHEN OUTDOOR TEMPERATURE IS ABOVE 55•F. AFTER OPERATING PRESSURES HAVE STABILIZED: MEASURE INDOOR WET BULB TEMP. - OUTDOOR TEMP. - HEAD AND SUCTION PRESSURES. LOCATE OUTDOOR TEMP. O LOCATE INDOOR WET BULB 0 FIND INTERSECTION OF OD TEMP. & ID W.8. ® READ HEAD OR SUCTION PRESSURE IN LEFT- HAND COLUMN O (SELECT PROPER INDOOR CFM) ACTUAL HEAD PRESSURE SHOULD BE ± 10 PSIG OF CHART SUCTION PRESSURE SHOULD BE ± 3 PSIG OF CHART EXAMPLE: OOUTDOOR TEMP. 85•F., m INDOOR WET BULB 67°F., ® HEAD PRESSURE @ 1000 CFM = 220 PSIG 0 0 SUCTION PRESSURE®1000 CFM = 76 PSIG O page 5 HEAD PRESSURE IPSIGI CD a - w CC U) U) w CC a - z L0 0 3 Ln 400 350 300 250 200 150 100 PRESSURE CURVE — BTC036C-B INDOOR ENTERING WET BULB •F UPPER CURVE IS 71•F LOWER CURVE IS 59 100 95- 90 85 • 80 75 65 75 OUTDOOR INDOOR ENTERING WET BULB •F FROM TOP DOWN CURVES ARE: 7 'F 67•F, 63 F 59 F ...r o••• 85 95 105 115 TEMPERATURE (°F . ... • . . .. . .. i 11 r 70 ,...}n.,... 6 5 -�• 60 55 50 . x ■ .. .y} ■■ . ■ i• A 65 75 85 95 105 0 E o. 115 OUTDOOR TEMPERATURE 1°F) COOLING PERFORMANCE TO BE CHECKED WHEN OUTDOOR TEMPERATURE IS ABOVE 55'F. AFTER OPERATING PRESSURES HAVE STABIUZED:.MEASURE INDOOR WET BULB TEMP. — OUTDOOR TEMP. — HEAD AND SUCTION PRESSURES. LOCATE OUTDOOR TEMP. O LOCATE INDOOR WET BULB ® FIND INTERSECTION OF OD TEMP. & ID W.B. ® READ HEAD OR SUCTION PRESSURE IN LEFT- HAND COLUMN ® (SELECT PROPER INDOOR CFM) ACTUAL HEAD PRESSURE SHOULD BE ± 10 PSIG OF CHART SUCTION PRESSURE SHOULD BE ± 3 PSIG OF CHART EXAMPLE: O OUTDOOR TEMP. 85•F., ® INDOOR WET BULB 67°F.; ® HEAD PRESSURE ®1200 CFM - 230 PSIG m SUCTION PRESSURE ® 1200 CFM = 75 PSIG O page 6 TROUBLESHOOTING CHART — WHAT TO CHECK \'A SYSTEM FAULTS s` `� � y'. vn stonpet� n '9�$ ����y`����a t` '9 ri, Q REFRIGERANT CIRCUIT Liquid Pressure Too High P S P S S Liquid Pressure Too Low . S P S S S Suction Pressure Too High S P P S P Suction Pressure Too Low S S P S Liquid Retrig. Floodback TXV System S S Liquid Retrig. Floodback Capillary Tube System P S S S P I.D. Coil Frosting P P S Compressor Runs Inadequate or No Cooling S P P S S P S ELECTRICAL Compressor & 0.0. Fan Do Not Start P P SPPP Compressor Will Not Start But 0.D. Fan Runs P S P P P S 0.0. Fan Won't Start P P Compressor Hums But Won't Start P PPPS S Compressor Cydes on 101 PSPPPS PSPSS S S S 1.0. Blower Won't Start P S S P P page 7 The Trane Company Light Commercial Unitary Division Guthrie Highway Clarksville, TN 37040 Dwg. No. 21A722524 P01 P.I. 'PERMIT COORD COPY PLAN REVIEIM/ROUTING SLIP ACTIVITY NUMBER: M13-153 PROJECT NAME: TREK BICYCLES SITE ADDRESS: 331 TUKWILA PY X Original Plan Submittal Response to Correction Letter # DATE: 08-27-13 Response to Incomplete Letter # Revision # After Permit Issued DE`PARTMMENTS: B ding uivision Public Works n Fire Prevention Structural U Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 1:XJ Incomplete n DUE DATE: 08-29-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n DUE DATE: 09-26-13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Peter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company AIR MANAGEMENT SOLUTIONS LLC 3604796500 5822 Werner Rd Bremerton WA 98312 Kitsap Limited Liability Company UB1 No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602548114 Active AIRMAMS952QM Construction Contractor 11/14/2005 11/14/2013 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status POWELML950NE POWELL MECHANICAL LLC Construction Contractor Heating/Vent/Air -Conditioning And Ref rig (Hvac/R) Unused 8/5/2005 8/15/2009 Expired POWELSM972JJ POWELL SHEET METAL Construction Contractor Metal Fabrication Air Heat,Ventilation,Evaporat 4/ t 1 /2003 4/ 11 /2007 Out Of Business Business Owner Information Name Role Effective Date Expiration Date POWELL, TIMOTHY S Partner/Member 11/14/2005 Bond Amount MURPHY JR, ROBERT C Partner/Member 11/14/20(15 32s209776 POWELL, TRACY Partner/Member 11/14/2005 MURPHY, PATTY J Partner/Member 11/14/2005 American States Insurance Co Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 American States Insurance Co 32s209776 04/20/2012 Until Cancelled $12,000.00 05/11/2012 2 American States Insurance Co 6542468 12/17/2007 04/2(1/2012 $12,000.00 12/20/2007 1 AMERICAN STATES INS CO 6384369 10/26/2005 Until Cancelled 12/21/2007 $6,000.00 11 /14/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Nationwide Mutual Ins Co ACPGL07515469401 03/28/2013 03/28/2014 $1,000,000.00 03/21/2013 5 Allied Property Et Cas Ins Co ACP7505469401 03/28/2012 03/28/2013 $1,000,000.00 03/23/2012 4 Continental Western Ins Co CWP274465224 03/28/2011 03/28/2012 $1,000,000.00 03/10/2011 3 Continental Western Ins Co CWP274465223 03/28/2010 03/28/2011 $1,000,000.0003/18/2010 2 Continental Western Ins Co CNP2744652 03/28/2008 03/28/2010 $1,000,000.00 03/26/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 10/03/2013