HomeMy WebLinkAboutPermit M13-158 - WELLS FARGO BANK - ALTERATIONWELLS FARGO BANK 18035 SPERRY DR M13-158 City orl'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3623049095 Address: 18035 SPERRY DR TUKW Project Name: WELLS FARGO BANK Permit Number: M13-158 Issue Date: 09/20/2013 Permit Expires On: 03/19/2014 Owner: Name: FIRST INTERSTATE BANK Address: C/O THOMSON PROPERTY TAX , PO BOX 2609 92018 Contact Person: Name: JOFFRE SECHIER Address: 3202 C ST NE , AUBURN WA 98002 Email: JOFFRE@COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P-105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 251-9840 Phone: 425-251-9840 Expiration Date: 04/25/2014 DESCRIPTION OF WORK: REMOVE EXISTING MECHANICAL SYSTEM AND REPLACE (2) 6 -TON, (2) 4 -TON, (7) 3 -TON, AND (1) 2 -TON GAS PACKAGED ROOFTOP UNITS WITH CURBS ECONOMIZERS. MODIFY EXISTING AIR DISTRIBUTION TO CONNECT TO NEW ROOFTOP UNITS. Value of Mechanical: 110,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $1,469.63 International Mechanical Code Edition: 2012 Permit Center Authorized Signature: Date: 1'3 I hereby certify that I have read and -xam ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • with, whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or theerformance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permi Signature: Print Name: 1�^ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Printari• nQ_9n_9n13 PERMIT CONDITIONS Permit No. M13-158 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***FIRE DEPARTMENT CONDITIONS*** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206) 575-4407. doc: IMC -4/10 M13-158 Printed: 09-20-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila. It',1 98/88 http://www.TukwilaW A.gov Mechanical Permit No. Project No:. Date Application Accepted: Date Application Expires: 0022 I7 (For office use rn►h) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 18035 SPERRY DRIVE WELLS FARGO BANK King Co Assessor's Tax No.: 3623049094 Suite Number: Floor: New Tenant: ❑ Yes ®..No PROPERTY OWNER. Name: JOFFRE SECHIER Name: WELLS FARGO BANK City: AUBURN State: WA Zip: 98002 Address: 18035 SPERRY DRIVE Zip: 98002 City: TUKWILA State: WA Zip: 98188 CONTACT PERSON - person receiving all project communication Name: JOFFRE SECHIER Address: 3202 C ST NE City: AUBURN State: WA Zip: 98002 City: AUBURN State: WA Zip: 98002 Phone: (425) 251-9840 Fax: (253) 736-6598 Email: joffre@comfortmech.com MECHANICAL CONTRACTOR INFORMATION Company Name: COMFORT MECHANICAL Address: 3202 C ST NE City: AUBURN State: WA Zip: 98002 Phone: (425) 251-9840 Fax: (253) 736-6598 Contr Reg No.: COMFOMI0I5LA Exp Date: 04/25/2014 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ 110,000 -� Describe the scope of work in detail: REMOVE EXISTING MECHANICAL SYSTEM AND REPLACE WITH (2) 6 -TON, (2) 4 -TON, (7) 3 -TON, & (1) 2 -TON GAS PACKAGED ROOFTOP UNITS WITH CURBS ECONOMIZERS. MODIFY EXISTING AIR DISTRIBUTION TO CONNECT TO NEW ROOFTOP UNITS. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric ❑ Gas m Other: II: \Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I Ldocx Revised: August 2011 bh !'age I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <IOOk btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/reirig/cooling system Air handling unit <10,000 cfm 12 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100.000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750.000 btu PERIVIIT APP ICIA'TION•NOTES :4,* Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I 1 -HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TI -IE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: (-AUTHORIZED AGENT: Mailing Address: E SECHIER 3202 C ST NE II: \ Applications \Forms -Applications On Line\201 I Applications\Mechanical Permit Application Revised 8.9.1 I.docx Revised: August 2011 bh Date: 08/29/2013 Day Telephone: (425) 251-9840 AUBURN WA 98002 City State Zip Page 2 of 2 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $165.00 M13-158 Address: 18035 SPERRY DR Apn: 3623049095 $165.00 FIRE ALARM 06/24/2014 PMCC $100.00 FIRE ALARM 06/24/2014 PMCC R000.342.400.02.00 0.00 $100.00 MECHANICAL FINAL 06/24/2014 CMAR $65.00 MECHANICAL FINAL 06/24/2014 CMAR TOTAL FEES PAID BY RECEIPT: R2532 R000.322.800.00.00 0.00 $65.00 $165.00 Date Paid: Monday, July 07, 2014 Paid By: JESSE A CHUTICH Pay Method: CREDIT CARD 117041 Printed: Monday, July 07, 2014 9:14 AM 1 of 1 Aee_3 )(2.-/c47 CJRWSYSTEMS r• City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.Tukwila WA.gov RECEIPT Parcel No.: 3623049095 Permit Number: M13-158 Address: 18035 SPERRY DR TUKW Status: APPROVED Suite No: Applied Date: 08/29/2013 Applicant: WELLS FARGO BANK Issue Date: Receipt No.: R13-02690 Initials: User ID: JEM 1165 Payment Amount: $1,175.70 Payment Date: 09/20/2013 11:37 AM Balance: $0.00 Payee: JOFFRE T SECHIER, COMFORT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 310273 ACCOUNT ITEM LIST: Description 1,175.70 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,175.70 Total„ $1,175.70 rinr• Roroin4-fC. Printed: 09-20-2013 I City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 3623049095 Address: 18035 SPERRY DR TUKW Suite No: Applicant: WELLS FARGO BANK RECEIPT Permit Number: M13-158 Status: PENDING Applied Date: 08/29/2013 Issue Date: Receipt No.: R13-02504 Initials: User ID: JEM 1165 Payment Amount: $293.93 Payment Date: 08/29/2013 01:20 PM Balance: $1,175.70 Payee: JOFFRE T SECHIER, COMFORT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 519202 ACCOUNT ITEM LIST: Description 293.93 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 293.93 Total: $293.93 rinr• Raraint-nR Printed: 08-29-2013 4t5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431-3670 Permit Inspection Request Line (206) 431-2451 (141,3 Project:Type L,0 of Inspection: MMner,.'4,J\.AL Address:�,. l 50 ' 5P�rf \I Date Called: `7)r\fr) ►%e _---.� �,'� ,;a T); LA - -.- r.: m: p.m. Special Instructions: T iDate i Wanted: -1— Requester: P(ione No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 014. rT Li 5 i' GoM1Q FIT( P Inspect 'r: \\'`t REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: �7�15-14 INSPECTION RECORD Retain a :copy with permit INSPECTION NO. PERMIT NO, CITY OF TUKWILA -BUILDING DIVISION 6300 Southcenter Blvd.,.#100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 L._ Project: �. / LAI ��S iGli( r,� Type of Inspection: JAI PC.1/1, ll:a(�--. Address: I 5d-35 5P err l Da.te'Called: Special Instructions: r Date Wanted:. j �6 - - .m. P.m. Requester: P one. No: ').V.-.7. E Approved per applicable codes. Corrections required prior to approval - COMMENTS: V: Inspect r: 1* -r 1/4AA--*. REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD [An Retain a copy with permit V 1 1 "t 5 <� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: \N F. tt S -c' kG 0 l Type of Inspection: , M Q e., .) F 1 itPs L. A r s: ddo3.5 S0eCr� Date Called: t /14 , f„.../Y---- Special Instructions: ( - 2(96-1 — 1L /2(96-1‘3— '2A Date Wanted: tt a...01... Requester: 5 !�f'-e_ //�< i t 7'L' p_ P1t N 4-) r, /1l,'" 14-. ' (D Approved per applicable codes. ,Corrections required prior to approval. COMMENTS: i) (47 , 71--- - .3 /14 , f„.../Y---- •,`7 o . �� / --c_r _ /-e-07 %/) (M r -7 ,/ 5 !�f'-e_ //�< i t 7'L' p_ ;: c - -L- e 6-67 AI H cPr ,l`',--/ 4-) r, /1l,'" 14-. ,<-. S/ -e" 1.--4--, 3 tep !Ie -2-Q -Id / .1.51 L, « �t r /�I�+ iii_ r h , Inspector: Date:5 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4v-3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Al CITY. OF TUKWILA.BUILDING DIVISION C� 6300 Southcenter: Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request. Line (206) 431-2451 Pro'ec : C --11S fA1 C20 -A^k T_ yp� f kkispe tion: rt rtv c I ..LAS. Address: 180 3 5 S efj ' Date Called: . Special Instructions: G-eeoi e Date Wanted: z La LA a.m. Requester: J'4MeS Phone No: . 20. Co -I f 3`- 3. -N: o I Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: c t &ID OK- Pou60- Inspector: n REINSPECTION FEE REQUIRED. Prior to nextinspection, fee must be paid at 6300 Southcenter Blvd.,-Suite.100..Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 4:31-2451 Project:Type 03eA_ I i Lo o I spection: .--- , >6_ cLEQ;. Jr-kr—J3--t Address: 1,33- SF:L't2Y Da. a Called: Speciaflnstructions:. �� /--1 ( 7 2 0.e°'I 7 ,Oco () tiY 3 S~ Date Wanted: ��jj 1 .... �'l — 1 L' a.m. p.m. ueste . i A � es 3E-33 -3 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6K 1-D errP i`nso ,r f -'D A-, 4 7 ,s - A -1-47:1M Inspector: n REINSPECTION FEE REQUIRED. dor to next inspection, fee must be.. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit E T NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t�c11S {- (R6p Type of Inspection: gime11A-ri\J Address: 1 CSO3S SefQI � DR Date Called: ;itc-1 -ItJcii Special Instructions: Date Wanted:,/ 1 —7" 1 tet m. : T: Requester: �Pr1M5C Phone No: a.6(- (3 -36e= C.) JApproved per applicable codes. :1 Corrections required prior to approval. COMMENTS: 9, a '.k::k ;r� - ;Z(t, h -i til 4-rp pid42d, 11 bhp e -a- Qt. t[ d.k R-1kK (110,4 aA s`co ,....... `coC N vT fZ A t cr+J S At €Je k�i A t,Je s-1 -,;t6-(10 ise CG,i AP) L1S.)1 ' o'tes "1e ' Date` REINSPECTION FEE RE UIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: W':,�IC 1Ale) 0 Type of Inspection: :i,A,AA .Af1, Address: - Date Called: Special Instructions: : / . C % * ,, CI (03 ,54S9 4S9 Date Wanted:,4,. ? r-7 - %/ — � . a.m. p.m. Requester: ri :,:. 'av ()A Phone NO: r. ` , Approved per applicable codes. [1 Corrections required prior to approval. COMMENTS: 0 K `1`Y fry A't :'`- ()A fe,,, 7--Dp II r -- t\ -t Inspector: Date: -t n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ffi INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT ti 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Ai / da my 0 Type of Inspection: Fire Alarm: Address: Suite #: /80575- 5�/� Contact Person: <, , Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /IC 5./e,(7/4a/r) Y S Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /c-3''511-- Date: 7//s-hv Hrs.: / c $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 1j4/ 5 o Type of Inspection: 4 -- Address: Suite #: /V0`; S S N t Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: N-0 10 Mt 15 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: j( /2.1, S •— Date:�'/� y�/// Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 18 2013 City of Tukwila BUILDING DIVISION \J\Im- sc3./t4 •O � .o WAsy,-. O i - ► \Q 18959 p ,' ", �c� � %/o C' NA L E EXPIRES STRUCTURAL CALCULATIONS WFB RTUs 18035 Sperry Drive Tukwila, Washington AUGUST 26, 2013 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington Moore Engineering Group GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT RTU -1, RTU -5 -1,013 POUNDS RTU -2, 4, 6 - 9, 11, 12 - 680 POUNDS RTU -3, RTU -10 - 774 POUNDS EARTHQUAKE SDS = 0.903 SITE CLASS D to E WIND 85 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDIDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIEI) OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (2x MEMBERS) JOISTS: (3x MEMBERS) HEM -FIR NO.2 HEM -FIR NO.2 Fb = 850 PSI, Fv = 150 PSI Fb = 850 PSI, FA/ =150 PSI 8. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-2011. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 10. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. 11. CONNECT THE METAL CURB TO THE EXISTING ROOF DECK WITH A MINIMUM OF (3) #10 x 2" LONG WOOD SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT AND THE THIRD SCREW AT APPROXIMATELY THE MIDDLE OF THE UNIT ON EACH SIDE. 12. CONNECT THE NEW UNITS TO THE METAL CURB WITH A MINIMUM OF (2) #10 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT. PROTECT DESCRIPTION: The project consists of 12 new rooftop mechanical units LOADS: LIVE 25 PSF DEAD DEAD + LIVE WIND SEISMIC EQUIPMENT Roofing and re -roof 4.0 Plywood sheathing 3.4 4x14 @ 4' o.c. 3.0 Insulation 1.0 MEP 2.0 Ceiling & Lights 2.0 Total Dead 15.4 85 mph, Exposure B Latitude 47.441 Longitude -122.248 Site Class D to E SDS (D) = 0.951 SDS (E) = 0.855 SDs = 0.903 Units 1 and 5 1013 Dimensions 88"x60"x53" Units 2,4,6,7,8,9,11,12 Dimensions 680 74"x47"x45" Units 3 and 10 774 Dimensions 74"x47"x53" 40.4 PSF Moore Engineering Group PROJECT: ENGR: DATE: $ 5 SCALE: 6,4 SHEET Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mi... USGS Design Maps Summary Report User -Specified Input Report Title WFB - Rooftop Units Mon August 26, 2013 16:15:30 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.441°N, 122.248°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III 55mi. ;> ;5000m East Renton; Highlands.: Vashon mapquest? USGS-Provided Output S5 = 1.426 g S1 = 0.531 g SMs = 1.283 g SM. = 1.275 g Sos = 0.855 g Sol = 0.850 g @ MapQuest For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.43 1.30 1.17 1.04 0.91 01 0.78 fp 0.65 0.52 0.39 0.26 0.13 0.00 MCER Response Spectrum 0.99 0.90 0.81 0.72 0.63 C 0.54 to 0.45 0.36 0.27 0.19 0.09 0.00 Design Response Spectrum 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 Period, T (sec) Period. T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 1 of 1 8/26/2013 9:15 AM Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mi... 4JSG$ Design Maps Summary Report User -Specified Input Report Title WFB - Rooftop Units Mon August 26, 2013 16:15:10 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.441°N, 122.248°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output SS = 1.426 g S1 = 0.531 g S = 1.426 g S = 0.797 g SDS = 0.951 g S01 = 0.531 g For Information on how the SS and Si. values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 • 0.90 0.75 0.60 0.45 0.20 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 1.10 1.00 0.90 0.80 0.70 C 0.60 {A 0.50 0.40 0.20 0.20 0.10 0.00 0.00 0.20 0.40 0.50 Design Response Spectrum 0.80 1.00 1.20 1.40 1.50 1.80 Period, T (sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 1 of 1 8/26/2013 9:15 AM Moore Engineering Group (A (B C D E F . e — — Ca •d I MIIIIIMERMINIM=MEs' • • Y/ w 'm FCD' r a•IaQ!'•d DG awma'•d AC. !•ua6 a'.0 OC, . • e t a.11pa'•. OC. !•»O.'d QC.` ♦•itO !'-O.O C, b J Ql Tr• .e• I Kae. xx. a . .DI •II 7 nor ..-- ' MOIL P ° _ ' •L 1 tam... ar NCR ; Y w/ - NOON m :. 9 OM +t N @ •`�ry d AP WWI. NWT T I VTR N I Q y A TI( nrRmo it LW ' L �, , l©©, `_. o A „ %ow, , • v ^ , , NT, ICU/A co.T 00031 I of moo Pow WTI Ii rr. 9a01l -..1 Ili ink i b c FNM 1• r� Air %�i . "1r -m 0 / .Sp 0rm da CINOrts NAUR TYPO MI DAAWNO 0.4 - O w a•» of 17 a6 . 416 6. w3 0 ROOF FRAMING PLAN NORTH GENERAL NOTES I. NO0 SUPPORTS 'ION TOXIN TAM AT ROOM SHALL Nu APPROHID BY CNOINItS PRION TO, ?ANIMATION ON INSTALLATION. wt'Oc�, •Ot ti • r�rnuI ! ma Coot VIM AT NIDSMN NCOHNN R0131 or 0111I SRR, Trot 0.10 CONPCNTI, Oat, 00 01011 Of Asc ?AMC. sorrow Pomp 0101 TAPS AT ii 00. 0 sr0Kr00M CDNCRITI WRR 4a -y( 14100 ARCH 4.1141•cowt .WRM fj'•a' •01ON• COP• 0001 IT (A. IND N 11'40. NAY. Tr, a•C , I tomato 0 �! CCNT. NdNt.i!'.0'OC. »w. A••3 VINL•o,cro . IN OR001(D CILLO 1 CORNtS DOW0I. TO MATCH VINT. 0000 001'.0 at. IRIfurl count( CONT Do4 Unit Report For RTU -115 Project WFB Lockbox Prepared By: 06/04/2013 10:38AM Unit Parameters Dimensions (ft. In.) & Weight (lb.) "' Unit Model:..__.____ ...... __.._..._._48HCEA07A2A6-0A0A0 Unit Length:.._..._............. .......................... ......_7' 4.125" Unit Size' ______ 07 (6 Tons) Unit Width:..._..__ 4' 11.5" Volts -Phase -Hertz:_.__.__ _-------.._....._.__._460.3.80 Unit Height:._. -----........._.._.__......_._......_.._......._..3' 5.25" Heating Type:..._........._......_..._. __ _..._....__....._..._......._.Gas *- Total Operating Weight ....._......._............ 1013 lb Duct Cfg:_....... __.___Vertical Supply / Vertical Return Medium Heat "' Weights and Dimensions are approximate. Weight does Single stage cooling models not include unit packaging. Approximate r mensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size* 1/2 Condensate Drain Line Size' 3/4 Return Air Filter Type* Throwaway Return Air Filter Quantity:._.. .... ._._._.._._....__............. _...4 Return Air Filter Size:..._...__...._......._...__...........18 x 20 x 2 Unit Configuration Medium Static Option - Belt Drive Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts 5 -Year compressor parts 10 -Year heat exchanger - Aluminized No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48HCEA07A2A6-0A0A0 Rooftop Unit 2 Accessories CRECOMZR021A03 Vertical EconoMi$er IV with solid-state controller 2 CRRFCURB003A01 14 -inch Tall Roof Curb 2 Packaged Rooftop Builder 1.36 • Page 3 of 28 4 Project: WFB Lockbox Prepared By: Certified Drawing for RTU -115 06/04/2013 10:38AM 401(5:( NILLI I. IMMEYSl0A1[AI33 „1I N(1183D1NEN510M5 2. S CENTER OF BRAUN I. 11.00, DIRECTION Of All FLO' BVIT J A N 44K-401 171 11048) 11041) 11 34 (0511 15 /4 3443) IONC•DID 41 3/1 (17531 30 370 11751 13 7/0 (*011 "144" 111 (12531 112571 5f 3)0 (1251 (5 2/0 1413) IILIER ACCESS PA4E1 C100. .1E551 CONTROL 001 ACCESS PANEL OPTIONAL fKTORT INSTALLED - 0250170WEC1 = — 145000 1101(0 ACCESS ROLE • 1161006 COIL ACCESS PANEL '=. . : ooN CONDENSER COIL ((I f ( 3.3,4 1151 RACK 4-5/1 Jr 4031 110241 UNITED PA. m IW 11C414000115 40,000. rt CARRIER .0) 3„Itta W 0Y10�1i� Y1101' L Ylfil l� LII. di it1i0a1 KfLO t ll to 1 rt!= q OOIW1A1 20.3/4 15211 17.54 13211 E AT. 0010[15*TE RAIN 0006)4) IN BAS(/AN I4411 II!!! 14 .. I `Aml 12151 L1C1R(CAI 018005NEC7 10[,1106 0Pn00AL TACt03T 181TAL1(5 CONVENIENCE ONSET 21.7/5 5132 115101 1ELL 2-$I 040) TIP CURB 0101 �--•� 21 515 (1511 L' 11001 IQP EE 1000 WE OAS( CNART t (LUC 100D 4401 0ETuIN AIN N.5/8 4.3a mipo 11551 110211 SUPPLY JA00 � -+ 3.1/4 14 ,.... (03) 11511 25.1/2 (841) 12230) FRONT ` 4.34 (1511 CONNECTION SIZES A 1 3/0' 1351 DIA FIELD POWER SUPPLI MOL( 7 1/2' 1141 DIA POWER SUPPLY 41004001 13/4' 1511 DIA GAUGE ACCESS PLUG 170. 1221 IIA fIELD CONTROL WIRING 40LL )14'•14 101 CONDENSATE MAIM 112'•10 1P1 DAS 0015ECTIOA 314'.14 IPI GAS CONNECTION 2 ' (S11 DIA POWER SUPPL) 10,004-081 THRU THE -BASE CHART (FIELD INET) CONTROL 001 ACCESS PANEL OPTIONAL fKTORT INSTALLED - 0250170WEC1 = — 145000 1101(0 ACCESS ROLE • 416E '=. . : ooN 1 -" c 0 1-311 1:1 21 31 14405 u 31 12230) FRONT ` 4.34 (1511 CONNECTION SIZES A 1 3/0' 1351 DIA FIELD POWER SUPPLI MOL( 7 1/2' 1141 DIA POWER SUPPLY 41004001 13/4' 1511 DIA GAUGE ACCESS PLUG 170. 1221 IIA fIELD CONTROL WIRING 40LL )14'•14 101 CONDENSATE MAIM 112'•10 1P1 DAS 0015ECTIOA 314'.14 IPI GAS CONNECTION 2 ' (S11 DIA POWER SUPPL) 10,004-081 THRU THE -BASE CHART (FIELD INET) TRIER VOLES 0054(00 FOR SE 017 ACCT 0175: ODTtlm11A01: 07 - OAS 1410 Cu 0 OR 45TTIIIPm15A13A01: 0011' OSGASGAOU lA CN Ct0TNPIR104A01: 05,01 - GAS 7060 OAOFPAN 100(00(0 416E 61011 ROLE CONDUIT SIZE USE SIZES 1080.) O 1/2' ACC. EIS' 122.21 I I/O' 242 711' 122.21 7 3/4' (001,0011 I 1/4' 1002.0041 POR- 1 14' 120.6) 1 3/4' 144.41 10031 1/2' OPT„„,1 1/0' 125.11 2 ' 10041 3/4' OPT 7 3/4' 144.41 (011 L 1021 PROVIDES 3/4' 021 1660 C015 ' 7LAM51 t 0111150. ROLE SIIE: 2' (30.01 THRU-THE-BASE CHART IFIOP) 301 '0Nt0-101-BASEPAN' /ACTON. 0P11011. 01/71161 000 ORLI' R. T• t 2 ARE PROVIDED. 44 000 BELOW LISTED N00(L5. A FIELD 50/PLIED 1/2' ADAPTER I5 0)003010 (EN BASE PAI 0177110 AND GAS VALVE: /M ” 40400.[,0.6.07 41400,1.00 45900,5-0 ' 1.34 12-5/1 1321 17211 AIRSUPPLY Jr (10151 RIGHT tRETURN AIR BARSNINIC RELIEF FLOW 100(1 1212 (8t/ 10.05.10 4801(4505 10-16-09 48HC 01-09 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48114502708 00 A Packaged Rooftop Builder 1.36 Page 4 of 28 Project: WFB Lockbox Prepared By: Certified Drawing for RTU -1)5 06/04/2013 10:36AM B A 8 7 2 ROCECLIO AOCESSORYI A p66CU1BO07101 NOIR • 1 1NSUA . 8A7T OFCUCTRESTCNCUE6 7, OF e sFoae wav WAammm 14W 8248 r Wl 431W 01W 1.8 !Mint -- pn.1J SUPKYPIE 81 EN. pgiaz 151319 [1981 GREW 161.1 F1ELOS1AR®1 vE"W a OORNEW TAL 0e90214,BcrnM616 CRSTIARAFOXECR THRU1NICU01 aSTIPIAmowat T1avn®mrw 1w/raper 1Q1127p,T 1W 44 SECTIONTNEUESDE SEE VIEW'S" CERBREDDRAMG pYNN01ECCGl1d rraCuctrN "1 ma 111 6�m Mom AG A. A. A- 7 w lSiiaGIWGTp -AG.' 6@S 109TA TaolTom MOM 5 AOOEOW61515/9j9281 VINs 18C 106. REY IEUSDNIC0113 Si airs AWD WAGPUNCH WSME l t87ffiEEL WIC 121I606 - 6Jgi, NoiMUM AG D CURBASY,RIXF 1ro60141 0101001.016 50HH06IIJ2 aQiT76 mei B t N M sumo. Packaged Rooftop Builder 1.36 Page 6 of 28 Unit Report For RTU -2,,41617,8%9,1112 Project WFB Lockbox Prepared By: 06/04/2013 10:38AM Unit Parameters Dimensions (ft. in.) & Weight (1b.)**" Unit Model- 48HCDAO4A2A6-0AOAO Unit Length. _-6' 2.376" Unit Size:___._..__..___ 04 (3 Tons) Unit Width:..._.._.._......__.._ _..____3' 10.75" Volts -Phase -Hertz..__ _....__...__460-3.60 Unit Height._____ __..._ 2' 9.376" Heating Type:..._..._.._ _...._ _Gas m Total Operating Weight_ .___.___.._.....__..:.880 lb Duct Cfg:_ ___...-_.__.Vertical Supply / Vertical Return Low Heat "' Weights end Dimensions are approximate. Weight does Single stage cooling models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size:_.. --- ....................._..-_.._._...------------___-----112 Condensate Drain Line Size• 3/4 Return Air Filter Type• Throwaway Return Air Filter Quantity. 2 • Return Air Filter Size: .... _..._........ ._ ..... _........ ...__._76 x 25 x 2 Unit Configuration Medium Static Option - Belt Drive Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts 5 -Year compressor parts 10 -Year heat exchanger - Aluminized No optional warranties were selected. NOTE: Please see Warranty Catalog 600-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48HCDA04A2A6-0AOA0 Rooftop Unit 8 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 8 CRRFCURB001A01 14 -inch Tall Roof Curb 8 Packaged Rooftop Builder 1.36 Page 12 of 28 Project WFB Lockbox Prepared By: Certified Drawing for RTU -21416171819)11112 06/04/2013 10:38AM NOTES: 1.QMRENSf08Ayl RLp R5 A8 INENSIONS 2. Si CENTER OF GRAVITY S DIRECTION OF AIR FLOW 1017 48710-404 13 IN 11471 II Ill 14711 4000.405 41 310 110311 14 718 1!111 4800.106 47 1/0 110111 143777100 FILTER ACCESS PANEL (TOOL -LOW • • COMP. ACCESS • PANEL 0 CONDENSER COIL 1 INDOOR COIL ACCESS PANIL 8 BACK 2'3/1 1111 TIP CURB WIDTH 44 11181 LECTR IC AL DISCONNECT 1004TI08 0 ONIIED r.o 4a 44 TECRR0L00111 41M:Y11, 41 CARRIER %41t wrouna•1 a n N C4Nu I1Y1111- a .44 ORa11w N lartrn oat-tNariirtr`1i (A.4a nii'4L 10-T/0 11111 41TL'RN [ ALT. CONDENSATE DRAIN OPEN1116 Y 60E44 16311 07110MAL TACT0R1 INSTALLED CONVENIENCE OUTLET 10-1/2 1441 3-3/4 1351 46 344 111011 LEFT OPTIONAL 1401007 INS TAILED DISCO/111C! 118011 FRONT 113/6 12411 6.1/0 11551 1018-T111.64)1 CUR THESE HOLES REWIRED 707 OSE CR8T1016001AO1. 003401 CONNECTION SIMS A 13/6' 7351 DIA FIELD POUR SUPPLI ROLE 8 2' 1501 DIA P0111 SOFIA 411001081 C 13/1. 7511 01A 0400E ACCESS PLO 0 1/8. 1221 DIA FIELD COMM 118110 ROLE E 311•-14 NPT 0081047 74 DOAIN F 1/2.14 OPT GAS CONNECTION 1 2 112 • 1641 DIA PORED SUM/ I100-011 1018-T111.64)1 CUR THESE HOLES REWIRED 707 OSE CR8T1016001AO1. 003401 111 RETURN I AIA I THREADED WIRE 010.0 HOLE 11-3/4 SUPPLY IA IR I 11 C010811 5120 USE 611E1 1144.1 W Ill' ACC. I/8. 112.31 7 1/7• 74v 1/0. 102.21 1 1 3/4. 1011,1031 IP0770 1170. 128.41 241 1003) 1/0. 771 1 GAS 1 3116. 130.01 TOR • 1Uu- TNE-101(08N• (ACTON( 01110X. FITTINGS FOR ONLY 0.1. 6 3 ARE PROVIDED SELECT E11HCR 7/4. OR 1/2• ' FOR POWER, DEPENDING Oh WIRE SIZE •• 10011 PROVIDES 371• PPT THN COIR FL4404 1 /111170. —+ 10-I12 10731 E 710. CONDENSATE MIN 111 RETURN I AIA I 11-3/4 SUPPLY IA IR I 11 1-114 1121 1110 6 11481 11771 72771 11!21 1-5/8 24 3/4 11811 71 I/4 11931 SUPPLE AIR ♦ 11111.001RIGHT AIR 48HC 04-06 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 1 OP 2 01/14/10 10/12/09 All OUTSIDE 4. 21-714 15301 BAROMETRIC RELIEF 7100 48TM502588 Packaged Rooftop Builder 1.36 Page 13 of 28 Unit Report For RTU -3%10 Project WFB Lockbox Prepared By: 06/04/2013 10:38AM Unit Parameters Unit Model_—..__..__.._..._..__.48HCEA06A2A6-0A0A0 Unit Size ------_----- _-------_.._05 (4 Tons) Volts -Phase -Hertz _...._..__.._ 460-3-60 Heating Type:..__._— Gas Duct Cfg:.__ Vertical Supply ! Vertical Return Medium Heat Single stage cooling models Lines and Filters Gas Line Size* 1/2 Condensate Drain Line Size _.._.._._....._..3/4 Return Air Filter Type- Throwaway Return Air Filter Quantity:_..____..._...._._ 4 Return Air Fitter Size __._...__._._._..16 sills 2 Unit Configuration Medium Static Option - Belt Drive Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts 5 -Year compressor parts 10 -Year heat exchanger - Aluminized No optional warranties were selected. Dimensions (ft. in.) & Weight (lb.) Unit Length:—___. _. 6' 2.376" Unit Width:-_------- _._....._....-----...._..3' 10.75" Unit Height_ _3' 6.376" '~ Total Operating Weight:_..__.__._.._____..._..774 lb •» Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 600-088 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48HCEA05A2A6-0A0A0 Rooftop Unit 2 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 2 CRRFCURB001A01 14 -inch Tall Roof Curb 2 Packaged Rooftop Builder 1.36 Page 21 of 28 Project: WFB Lockbox Prepared By: Certified Drawing for RTU -3110 06/04/2013 10:38AM 1/11"111E'll gLiIngtR1C.4""1"S 2 EFe (EATER Of GROOT 3 .1110. 0I6ECI104 Of AIR FLOW 484(.04 4014C.05 1484(.01 11 316 16 Oa (04)1 1021 It 176 14 10 10511 13111 21 310I 14 7/4 0 001 13711 • 32 Ill -1 10101 33 3/1 (8[61 17 ow 1ED 6. 111 wt. TEDWOOSILS (two/. 11. COR1E1 ual 13.,row Egaluipi thrtr.°11,thc.."` 112PFME11:16411m MI? 4411 RETON OR ITP COM 0070 11,40 1041 3.323 1351 LEF1 i 18.116 I 1011 I 11(ljl 174114 'all / E 41.1. • COhDERSAIE DRApt 00414 3ASTPAm N311 ----'- 1100 FLUE 2000 TOP -3.3/I --.- 12.14 (3111 11-1/2 14701 01101141. 0CIORT 11STALLED (1000NRECT 0035101104 11200 08. 051 DIA 01136 POOR SUPPLY OLE 2. 001 DIA POWER 02211 KOCKOUT 1 IIA' 1111 DIA 0400 ACCESS PLUG (Jr 1221 DTA 0IE10 COMO= 4141110 MOLE 344.-0 0.1 (0014541( oRmtm 1/?..14 317 OAS 0001101 104 G 2 lIZ• 1641 DIA POIER SUPPLY 4111101.001 140.111E.41 L C011 TOSE MOUS REWIRED FOR USE CUT402001401. 0039D1 , TOLADEO WIRE REO'D NMI 25.116 1430 , 4E020 Ali CORM( 0100 USE 4120 (MA1.1 4 1.2. ACC. 1/6. 122.21 X 1/2. /40 PO. 122.21 4 3.4. 4001,0031 POOR I 1/6. 126.41 tt. 10031 1/2. 01 OAS I 3/14' 130.01 filiiIn'il4E4NT7: 13"11 41411t0 ' SELECT 011004 PC 02 02. 203 POOR. DEP:ADM Om wit( 1120 I (000 1R00100 144. 40 7419 cot) „ FLAOE 61111163. 10.1/2 12611 l'311' 03(0. COROASAIE 0104 , ; m ' 25.116 1430 , 4E020 Ali k ; 14,9 5,3/4- ) 1011 3 . SUPRA AIR FRONI 11771 26.341 - 16111 )1 1/4 11831 AIR SOW 4 RIGHT I min I WI 32261113631 1 486C 04-06 SINGLE ZONE ELECTRICAL 2 1 01/14/10 10/12/09 COOLING WITH GAS HEAT .11 REIM 144 1ARIDOIRIC 1(L1EF 1209 d8TM502588 .11 A Packaged Rooftop Builder 1.36 Page 22 of 28 S-PAJ 4 (i;e1,4) 14; 1,6 cLorAl 11 t r: e w t= "at'rn,ONF L--2• Z t, l (irr 2SJ to u' cr �..- I Moore Engineering Group PROJECT: ENGR: J DATE: 7 / V' /�.3 SCALE: // ig SHEET id) 1 ' \A, — r (7.(0)(--.)//ct lS{vtiL �j-f .T ,okfJ: n1 = qGz m .(3) co �cz`i 0.0L- SiEcJj 174,4- a 4 74,4 1349 o (2-14,-(0 7143 Moore Engineering Group PROJECT: ENGR: DATE: SCALE: F SHEET 6/2/2014 City of Tukwila Department of Community Development JOFFRE SECHIER 3202 C ST NE AUBURN, WA 98002 RE: Permit No. M13-158 WELLS FARGO BANK 18035 SPERRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/29/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/29/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Marshall Technician M13-158 6300 Southcenter Boulevard Suite #100 • Tulnvila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-158 DATE: 08/29/13 PROJECT NAME: WELLS FARGO BANK SITE ADDRESS: 18035 SPERRY DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after Permit Issued DEPARTMENTS: •()C. Building Division IN Public Works Pc:\14 Cita' Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09/03/13 Complete 1p Incomplete Not Applicable 0 Comments: •c;), ;:r"," • : „: . ' '" ''47:4; A - ''`A• INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please RoutelStructural Review Required 0 No further Review Required 0 REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/01/13 Approved 0 Approved with Conditions Notation: REVIEWER'S INITIALS: Not Approved (attach comments) 0 DATE: Permit Center Use, Illy , CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW Staff Initials: Contractors or Tradespeople Pter Friendly Page Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company COMFORT MECHANICAL INC 4252519840 3202 C Street Ne Auburn WA 98002 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601954041 Active COMFOMI004DA Electrical Contractor 3/1/2000 3/1/2014 Hvac/Rfrg Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date • Status COMFOMI965MT COMFORT MECHANICAL INC Electrical Contractor Maintenance Unused 7/30/2004 7/30/2006 Expired Electrical Administrator INFORMATION License JACKSH'941 PW Name JACKSON, HERB Status Active Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A Violation Amount 01/01/1980 5/23/2013 JACKSON, HERB ELECTRICAL CITATION 01/01/1980 $250.00 LPSL CORPORATE SERVICES INC Agent 05/13/1999 ELECTRICAL CITATION Bond Information Bond Company Name CBIC Bond 1 Page 1 of 1 Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date SC6013 02/18/2000 Until Cancelled $4,000.00 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons/Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions/Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ESLOD00560 5/23/2013 WAC 296 -46B -901(1)(b)&(7) ELECTRICAL CITATION Satisfied $250.00 ESLOD00561 5/23/2013 19.28.041 RCW ELECTRICAL CITATION Satisfied $500.00 EBERA00381 3/5/2012 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 httns://fortress.wa.aov/lni/bbin/Print.asnx 09/20/2013 WELLS FARG+ BANK LOCKBOX SYSTEM .UPGRADES SYMBOL LIST SYMBOL ABBV. DESCRIPTION SYMBOL ABBV. DESCRIPTION G C Ell 1 ao 20x12 12"0 20x12 —0 —4I G C VD MD BDD SFD FD RAD SD BALL VALVE GAS CONDENSATE DUCT SECTION - SUPPLY DUCT SECTION RETURN RECTANGULAR DUCT (INSIDE DIMENSION) ROUND DUCT SOUND LINED DUCT (INSIDE DIMENSION) FLEXIBLE DUCT ADJUSTABLE AIR EXTRACTOR TURNING VANE VOLUME DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER COMBINATION SMOKE/FIRE DAMPER FIRE DAMPER CEILING RADIATION DAMPER DUCT SMOKE DETECTOR RELIEF AIR RELIEF AIR SHALL BE PROVIDED BY THE FOLLOWING METHOD(S): RELIEF PROVIDED BY ROOF -TOP UNITS. CONDENSATE DRAINAGE CONDENSATE DRAINAGE SHALL BE SIZED PER THE FOLLOWING TABLE 307.2.2 FROM THE INTERNATIONAL MECHANICAL CODE. PER MANUFACTURERS REQUIREMENT CONDENSATE DRAINAGE SHALL HAVE A P -TRAP WITH A VENT: AUXILIARY DRAIN SYSTEMS FOR ANY CONDENSATE PRODUCING EQUIPMENT IN A CONFIGURATION THAT MAY CAUSE DAMAGE TO THE BUILDING IN THE EVENT OF A PRIMARY CONDENSATE DRAINAGE FAILURE SHALL BE PROVIDED WITH AUXILIARY PROTECTION PER THE INTERNATIONAL MECHANICAL CODE SECTION 307.2.3 OPTION 4. ALL CONDENSATE PRODUCING EQUIPMENT SHALL HAVE A P -TRAP AND VENT PER THE DETAIL BELOW. PROVIDE CONDENSATE PIPING TERMINATING AT NEAREST APPROVED FIXTURE ON ALL CONDENSATE PRODUCING EQUIPMENT. TABLE 307.2.2 CONDENSATE DRAIN SIZING EQUIPMENT CAPACITY MINIMUM CONDENSATE PIPE DIAMETER UP TO 20 TONS OF REFRIGERATION 3/4" OVER 20 TONS TO 40 TONS OF REFRIGERATION 1" OVER 40 TONS TO 90 TONS OF REFRIGERATION 1-1/4" OVER 90 TONS TO 125 TONS OF REFRIGERATION 1-1(2" OVER 125 TONS TO 250 TONS OF REFRIGERATION 2 AIR BALANCE CALCULATIONS RTU -1 RTU -2 RTU -3 RTU -4 RTU -5 RTU -6 RTU -7 RTU -8 RTU -9 RTU -10 RTU -11 RTU -12 EF -1 EF -1 EF -2 EXHAUST 600 300 400 300 600 300 300 300 300 400 300 300 10"0 CDL 300 CFM `\ T'STAT S AFF ARCH. CDS CDL CGS CGL COP X DWG E, EXIST. ELECT. EC EER EFF FR GC HSPF HWR HWG I.E. IPLV LWR LING MC MECH. OFCI POC TYP. U.O.N. THERMOSTAT SWITCH ABOVE FINISHED FLOOR ARCHITECT/ARCHITECTURAL CEILING DIFFUSER -SURFACE MOUNTED CEILING DIFFUSER -LAY IN CEILING GRILLE -SURFACE MOUNTED CEILING GRILLE -LAY IN COEFFICIENT OF PERFORMANCE DEMOLISH DRAWING EXISTING ITEMS ELECTRICAL ELECTRICAL CONTRACTOR ENERGY EFFICIENCY RATING EFFICIENCY/EFFICIENT FLOOR REGISTER GENERAL CONTRACTOR HEATING SEASONAL PERFORMANCE FACTOR HIGH WALL REGISTER HIGH WALL GRILLE INVERT ELEVATION INTEGRATED PART LOAD VALUE LOW WALL REGISTER LOW WALL GRILLE MECHANICAL CONTRACTOR MECHANICAL OWNER FURNISHED, CONTRACTOR INSTALLED POINT OF CONNECTION TYPICAL UNLESS OTHERWISE NOTED PLUMBING FIXTURE TAG (125) 640 300 500 TOTAL POSITIVE PRESSURE 4,400 1,440 SEF'AR. ATE PERMIT REQUIRED FOR: O Plachanical 4Electrical Plumbing Gas Piping C;;► of Tukwila Ell I i "h,r:4 DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT:: Revisions will require a new plan submittal and may include additional plan review fees. EQUIPMENT TAG FLAG NOTE CONNECTION (NECK) SIZE TYPE (CEILING DIFF. LAY -IN) FLOW RATE (CUBIC FEET PER MINUTE) FIXTURE UNITS or BTUH PIPE SIZE DETAIL NUMBER SHEET ON WHICH DETAIL IS DRAWN SECTION INDICATOR SHEET ON WHICH SECTION IS DRAWN REVISION TAG GENERAL NOTES INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER I.B.C. REQUIREMENTS. MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY REFLECT EVERY REQUIRED OFF -SET, FITTING OR ACCESSORY. COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE AND ALL OTHER TRADES. THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BEGINNING WORK ORDER TO OBSERVE EXISTING CONDITIONS. VERIFY EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, PIPES, UTILITIES AND BUILDING STRUCTURE. VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. IN 2012 IECC WASHINGTON STATE ENERGY CODE NOTES REVIEWED FOR CODE COMPLIANCE APPROVED * MOTOR INTERLOCK BY MC ; FIRE ALARM CONNECTION BY EC. GAS PRESSURE CONTRACTOR SHALL COORDINATE GAS PRESSURE DELIVER WITH PUGET PROVIDE 2 PSI GAS. PROVIDE GAS PRESSURE REGULATOR AS REQUIRED BY EQUIPMENT TO FROM 2 PSI OR 5 PSI TO REQUIREMENT ON EQUIPMENT. USE OF A GAS PRESSURE REGULATOR THAT REQUIRES VENTING SHALL SECTION 410.3 OF THE INTERNATIONAL FUEL GAS CODE. ENERGY TO DROP PRESSURE CONFORM WITH DRAWING INDEX MECHANICAL ELECTRICAL COORD. i:. Brun. M-1.0 UNLESS OTHERWISE INDICATED, ALL MECHANICAL EQUIPMENT MOTORS AND CONTROLS SHALL BE FURNISHED, SET IN PLACE AND WIRED IN ACCORDANCE WITH DIVISION 15 OR 16 PER THE FOLLOWING SCHEDULE. ITEM FURNISHED BY SET BY POWER WIRING CONTROL WIRING EQUIPMENT MOTORS CONTROL RELAYS AND TRANSFORMERS LINE VOLTAGE T'STATS AND. - NITCHES LOW OLTAGE T'STATS TEMPORARY HEATING CONNECTION DUCT MOUNTED SMOKE DETECTORS 15 15 15 15 15 16 15 15 15 15 15 15 16 15 15 15 16 16 15 15 -- 15 15 15/16* * MOTOR INTERLOCK BY MC ; FIRE ALARM CONNECTION BY EC. GAS PRESSURE CONTRACTOR SHALL COORDINATE GAS PRESSURE DELIVER WITH PUGET PROVIDE 2 PSI GAS. PROVIDE GAS PRESSURE REGULATOR AS REQUIRED BY EQUIPMENT TO FROM 2 PSI OR 5 PSI TO REQUIREMENT ON EQUIPMENT. USE OF A GAS PRESSURE REGULATOR THAT REQUIRES VENTING SHALL SECTION 410.3 OF THE INTERNATIONAL FUEL GAS CODE. ENERGY TO DROP PRESSURE CONFORM WITH DRAWING INDEX SHEET DESCRIPTION M-1.0 COVER SHEET M-1.1 SCHEDULES M-2.0 FIRST FLOOR PLAN HVAC - DEMO M-3.0 FIRST FLOOR PLAN HVAC - NEW M-3.1 ROOF PLAN HVAC - NEW M-4.0 DETAILS FILE COPY Permit No.M Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fi b and melons is acknowledged: B City O?ltskwila BUILDING DIVISION EP 182013 o kwila IN i _VISION C403.1 GENERAL. MECHANICAL SYSTEMS AND EQUIPMENT SERVING HEATING, COOLING, VENTILATING, AND OTHER NEEDS SHALL COMPLY WIVE SECTIONS C403.2 & C403.4 (COMPLEX SYSTEMS). C403.2 PROVISIONS APPLICABLE TO ALL MECHANICAL SYSTEMS (MANDATORY). MECHANICAL SYSTEMS AND EQUIPMENT SERVING THE BUILDING HEATING, COOLING OR VENTILATING NEEDS SHALL COMPLY WITH SECTIONS C403.2.1 THROUGH C403.2.11. C403.2.1 CALCULATION OF HEATING AND COOLING LOADS. DESIGN LOADS SHALL BE DETERMINED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED IN ANSI/ASHRAE/ACCA STANDARD 183. THE DESIGN LOADS SHALL ACCOUNT 7OR THE BUILDING ENVELOPE, LIGHTING, VENTILATION AND OCCUPANCY LOADS BASED ON THE PROJECT DESIGN. HEATING AND COOLING LOADS SHALL BE ADJUSTED TO ACCOUNT FOR LOAD REDUCTIONS THAT ARE ACHIEVED +NHERE ENERGY RECOVERY SYSTEMS ARE UTILIZED IN THE HVAC SYSTEM IN ACCORDANCE WITH THE ASHRAE HVAC SYSTEMS AND EQUIPMENT HANDBOOK. ALTERNATIVELY, DESIGN LOADS SHALL BE DETERMINED BY AN APPROVED QUIVALENT COMPUTATION PROCEDURE. 403.2.2 EQUIPMENT AND SYSTEM SIZING. THE OUTPUT CAPACITY OF HEATING AND COOLING EQUIPMENT AND SYSTEMS SHALL NOT EXCEED THE LOADS CALCULATED IN ACCORDANCE WITH SECTION C403.2.1. A SINGLE PIECE OF EQUIPMENT PROVIDING BOTH HEATING AND COOLING SHALL SATISFY THIS PROVISION FOR ONE FUNCTION WITH THE CAPACITY FOR THE OTHER FUNCTION AS SMALL AS POSSIBLE, WITHIN AVAILABLE EQUIPMENT OPTIONS. C403.2.4 HVAC SYSTEM CONTROLS. EACH HEATING AND COOLING SYSTEM SHALL BE PROVIDED WITH THERMOSTATIC CONTROLS AS SPECIFIED IN SECTION C403.2.4.1, C403.2.4.2, C403.2.4,3, C403.2.4.4, C403.4.1, C403.4.2, C403.4.3, C403.4.4, C403.4.5, C403.4.6, C403.4.7, C403.4.8, C403.4.9, OR C403.4.10. C403.2.3 HVAC EQUIPMENT PERFORMANCE REQUIREMENTS. EQUIPMENT SHALL MEET THE MINIMUM EFFICIENCY REQUIREMENTS OF TABLES C403.2.3(1), C403.2.3(2), C403.2.3(3), C403.2.3(4), C403.2.3(5), C403.2.3(6), C403.2.3(7) AND C403.2.3(8)WHEN TESTED AND RATED IN ACCORDANCE WITH THE APPLICABLE TEST PROCEDURE. THE EFFICIENCY SHALL BE VERIFIED THROUGH CERTIFICATION AND LISTED UNDER AN APPROVED CERTIFICATION PROGRAM OR, IF NO CERTIFICATION PROGRAM EXISTS, THE EQUIPMENT EFFICIENCY RATINGS SHALL BE SUPPORTED BY DATA FURNISHED BY THE MANUFACTURER. WHERE MULTIPLE RATING CONDITIONS OR PERFORMANCE REQUIREMENTS ARE PROVIDED, THE EQUIPMENT SHALL SATISFY ALL STATED REQUIREMENTS. C403.2.4.1 THERMOSTATIC CONTROLS. THE SUPPLY OF HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN THE ZONE. AT A MINIMUM, EACH FLOOR OF A BUILDING SHALL BE CONSIDERED AS A SEPARATE ZONE. CONTROLS ON SYSTEMS REQUIRED TO HAVE ECONOMIZERS AND SERVING SINGLE ZONES SHALL HAVE MULTIPLE COOLING STAGE CAPABILITY AND ACTIVATE THE ECONOMIZER WHEN APPROPRIATE AS THE FIRST STAGE OF COOLING. SEE SECTION C403.3.1 OR C403.4.1 FOR FURTHER ECONOMIZER REQUIREMENTS. C403.2.4.2 SETPOINT OVERLAP RESTRICTION. WHERE USED TO CONTROL BOTH HEATING AND COOLING, ZONE THERMOSTATIC CONTROLS SHALL PROVIDE A TEMPERATURE RANGE OR DEADBAND OF AT LEAST 5F (2.8'C) WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY TO THE ZONE IS CAPABLE OF BEING SHUT OFF OR REDUCED TO A MINIMUM. C403.2.4.3 OFF -HOUR CONTROLS. FOR ALL OCCUPANCIES OTHER THAN GROUP R, EACH ZONE SHALL BE PROVIDED WITH THERMOSTATIC SETBACK CONTROLS THAT ARE CONTROLLED BY EITHER AN AUTOMATIC TIME CLOCK OR PROGRAMMABLE CONTROL SYSTEM. EXCEPTIONS: 1. ZONES THAT WILL BE OPERATED. CONTINUOUSLY. 2. ZONES WITH A FULL !VAC LOAD DEMAND NOT EXCEEDING 6,800 BTU/H (2 KW) AND HAVING A READILY ACCESSIBLE MANUAL SHUTOFF SWITCH. C403.2.4.3.1 THERMOSTAT;•C SETBACK CAPABILITIES. THERMOSTATIC SETBACK CONTROLS SHALL HAVE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55T (13'C) OR UP TO 85T (29'C). C403.2.4.3.2 AUTOMATIC SETBACK AND SHUTDOWN CAPABILITIES. AUTOMATIC TIME CLOCK OR PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK AND RETAINING THEIR,: PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST 10 HOURS. ADDITIONALLY, THE CONTROLS SHALL HAVE A MANUAL OVERRIDE THAT ALLOWS TEMPORARY OPERATION OF THE SYSTEM FOR UP TO 2 HOURS; A MANUALLY OPERATED TIMER CAPABLE OF BEING ADJUSTED TO OPERATE THE SYSTEM FOR UP TO 2 HOURS; OR AN OCCUPANCY SENSOR. C403.2.4.3.3 AUTOMATIC START CAPABILITIES. AUTOMATIC START CONTROLS SHALL BE PROVIDED FOR EACH HVAC SYSTEM. THE CONTROLS SHALL BE CAPABLE OF AUTOMATICALLY ADJUSTING THE DAILY START TIME OF THE HVAC SYSTEM IN ORDER TO BRING EACH SPACE TO THE DESIRED OCCUPIED TEMPERATURE IMMEDIATELY PRIOR TO SCHEDULED OCCUPANCY. C403.2.4.4 SHUTOFF DAMPER CONTROLS. BOTH OUTDOOR AIR SUPPLY AND EXHAUST DUCTS SHALL BE EQUIPPED WITH MOTORIZED DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE SYSTEMS OR SPACES SERVED ARE NOT IN USE OR DURING BUILDING WARM-UP, COOLDOWN, AND SETBACK. EXCEPTIONS: 1. GRAVITY RELIEF DAMPERS SERVING SYSTEMS LESS THAN 5,000 CFM TOTAL SUPPLY SHALL BE PERMITTED IN BUILDINGS LESS THAN THREE STORIES IN HEIGHT. 0403.2.4.10 DIRECT DIGITAL CONTROL SYSTEM CAPABILITIES. ALL COMPLEX SYSTEMS EQUIPPED WITH DIRECT DIGITAL CONTROL (DDC) SYS1EMS AND ALL BUILDINGS WITH TOTAL COOLING CAPACITY EXCEEDING 780,000 BTU/H (2,662 KW) SHALL HAVE THE FOLLOWING CAPABILITY: 1. TRENDING: ALL CONTROL SYSTEM INPUT AND OUTPUT POINTS SHALL BE ACCESSIBLE AND PROGRAMMED FOR TRENDING, AND A GRAPHIC TRENDING PACKAGE SHALL BE PROVIDED WITH THE CONTROL SYSTEM. 2. DEMAND RESPONSE SETPOINT ADJUSTMENT: CONTROL LOGIC SHALL INCREASE THE COOLING ZONE SET POINTS BY AT LEAST 2'F (VC) AND REDUCE THE HEATING ZONE SET POINTS BY AT LEAST 2'F (VC) WHEN ACTIVATED BY A DEMAND RESPONSE SIGNAL. THE DEMAND RESPONSE SIGNAL SHALL BE A BINARY INPUT TO THE CONTROL SYSTEM OR OTHER INTERFACE APPROVED BY THE SERVING ELECTRIC UTILITY. C403.2.5 VENTILATION. VENTILATION, EITHER NATURAL OR MECHANICAL, SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL PROVIDE THE CAPABILITY TO REDUCE THE OUTDOOR AIR SUPPLY TO THE MINIMUM REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE. C403.2.7.2 ALL OTHER SUPPLY AND RETURN AIR DUCTS AND PLENUMS SHALL BE INSULATED WITH A MINIMUM OF R-6 INSULATION WHERE LOCATED IN UNCONDITIONED SPACES AND A MINIMUM OF R-8 INSULATION WHERE LOCATED OUTSIDE THE BUILDING. WHERE LOCATED WITHIN A BUILDING ENVELOPE ASSEMBLY, THE DUCT OR PLENUM SHALL BE SEPARATED FROM THE BUILDING EXTERIOR OR UNCONDITIONED OR EXEMPT SPACES BY MINIMUM INSULATION VALUE AS REQUIRED FOR EXTERIOR WALLS BY SECTION C402.2.3. EXCEPTIONS: 1. WHERE LOCATED WITHIN EQUIPMENT. 2. WHERE THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15'F (8'C). C403.2.7.3.1 LOW-PRESSURE DUCT SYSTEMS. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES WATER GAUGE (W.G.) (500 PA) SHALL BE SECURELY FASTENED AND SEALED WITH WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC -PLUS EMBEDDED -FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY INDICATED ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE. EXCEPTION: CONTINUOUSLY WELDED AND LOCKING -TYPE LONGITUDINAL JOINTS AND SEAMS ON DUCTS OPERATING AT STATIC PRESSURES LESS THAN 2 INCHES WATER GAUGE (W.G.) (500 PA) PRESSURE CLASSIFICATION. RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER REVISIONS U n n ry 0 672-2084 FAX ° o Lc) CO N d- a.) (I)— 00 C. ui .5y Co LJ0 V.)° CP 0N N 0 cO co az c Lc) CN:' c N 00° 0 N W LU O DATE: SCALE: DRAWN: CHECKED: 03101/13 NTS SR RH M-1.0 12.028 AIR TERMI AL 'UNIT SCHEDULE I TIEM ri4ARK MANLYFACTIURER 1 1OtEL, MATERIL MOUNTI N a: FINISH. F�.Ehifi,RKS: CEILING GRILLE CGS TIlu'S. 50F AL1 MINUM SURFACE. E11;11LECI: 6[DRCER TYPE 1' CEILING DIFFUSER CDL Tints STEEL LAY It>I:' ENAF' 1LED CEILING GRILLE CGL TITUS 50F ALIflt1.INUM LAY-Ihk! E,tFAr 1LE[ ' 6.3RDER TYPE` �;' :.9C3RpER TYPE 3> NTE: NECKCU. NNECTIONSIZEANDTERMINALSIZE .S.NOTED.UI'r!FLOORPIAI GAS FIRED PACKAGED ROOFTOP UNIT SCHEDULE EQUIP: TAG h#.6'1 MODEL AREA SERVED DISCHARGE P L31ai IIr'AL TONS SUPPLY FAN DATA AIRFLOW CFM ESP in W.G. H. P. M O TO R DRIVE OUTSIDE AIR CFM' ECON. CYCLE COOLING DATA HEATING DATA ELECTRICAL DATA TOTAL MBH SENS. MBH SEER CODE SEER INPUT MB Ft OUTPUT MBH, AFUE %6 MCA VOLTS . ISH! WEI HT (LBS)' MUSE DB, P 1AR .:• . RTU;'1 RTU2 RTLI-3� RTU -4 R11.1-5. RTU CARRIER / EOHCQA07 CARRIER 48.XL-A3505003 CARRIER/ 48HCFAO5 CARRIE R � 48,�L.-. ;0503 CARRIER 1 50HCQA07 CARRIER I 48.X..-AMI0803. ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 :ZONE 5. Ru -r RTu$ CARRIER 48D443&0303. CARRIER/ 48)&-A35''0503,.: ZONE 7 ZONE 8 RTU -9 RTU -10 RIU-1:1 . RTU -1, 2 CARRIER 1 487A3e9603 CARRIER 1 481-CFA005 CARRIER i' 48NL-A350803 CARRIER ! 48>L -A'. t9603 ZONE 9 ZONE 10 ZONE 11:; ZONE 12' DOWN DO`I#'' DOWN DOWN''. DOWN DOW N DOW N DOWN 3 4' 2.400 3 2400iIMO' 1.0 0.7 0.7 0.7 1.0 0.e8 2 HP a'4 14P 1 HP 3'4HP 2 HP 3'4 HP BELT DIRECT BELT DIRECT BELT DIRECT 600 350 1000 20 0' YES YES YES YES 300 YES YES 752 55.9 12:13 EER+IEEER 33.8 48.7 33.8 75.2 30.2 44.1 30,2 53.9 33.8 30.24 15. 15.6: 15 1.213 EERIIEEE:R 5 11111.2 EERIEER 13 13 13 .1111 1.2 EER.+'IEER 13` '.. .120 OE 120 eo 120 to. 9!8 49' 9 '41 98 82% 82% 82% 82% 82%: 17 28.5 10.8 17 4 208, 4t0 208 3, 950. 3' COO 49' 82% 28.5: 2118 1 950 trio' 82 71. 1, 3, 4, 5, --= 1, 3 4, 5, 1, 3, 4, 5 1:,3,4, 5, 1,3,4, 5 :1, 3, 4; DOWN DOW I DOW N DOW N 3 3 3` 1 X70 1200 10 1600 12001 1200, 11.e& 0 £8 • 07 0: 7` 1'4 HP 3'4 HP: 2, 4 HP` • 1 HP DIRECT' DIRECT D IRECT BELT' DIRECT D IREC T 300 00 300 400 300 YES YES YES YES YES YES 33.8 2.3,.8 33..8 4B.'i 33.8 33.8 30.24 30.24 30.2 44.1 30 ? 30.2 15 15 15. 13.'.. 13 •13 • 13 13. 60 49.. 43 49 82% 82% 82% 82%. 820 82 28.5 28,5 28.5 10.8': 28.5: 28.5 3' 1 too` T1 3, 4, 5, 1,345, .... 1, 3, 4, ` 5,, 1,3,4, 5, 1. 3. 4, 5' 1, 3, 4, , 5, NOTES: 1. PROVIDE UNIT WITH 100%: FULLY MODULATING ECONOMIZER AND ALL REQUIRED CONTROLS 2. PROVIDE WITH POWER E)4-#AUST; 208V/1PH, '1/3I•iP 3. COOLING CAPACITY RATINGS ATS5F GUTDOOR, $ODB. e. 'ti'VB ENTERING AIR F 4. PROVIDE WITH FACTORY ROOF CURB 5. PROVIDE NEW TCS BASYS CONTROL SYSTEM. TCS BASYS CONTROLS SCHEDULE DAT - TS1002 DISCHARGE AIR TEMPERATURE SENSOR. DP -1 - PD1000 PRESSURE DIFFERENTIAL SWITCH. RS -1 - TS3010 REMOTE SENSOR. OSA - TS3003 OUTSIDE AIR SENSOR. CP -1 - QD2040 CONTROL PANEL WITH 1WL3.0 PACKAGE. PROVIDE SZ1031 THERMOSTAT FOR EACH UNIT IN IN CP -1, PROVIDE PK3100 UPS IN CP -1. R V E't h0� CODE C�OVf�I� CE APP SEP 18 2013 CONTROL SEQUENCE OF OPERATIONS RTU SEQUENCE OF OPERATIONS: SUPPLY FAN START/STOP: THE SUPPLY FAN WILL BE STARTEDACCORDING TO THE SCHEDULE. AFTER THE SUPPLY FAN HAS BEEN STARTED, THE CONTROL SEQUENCE WILL BE ENABLED. ZONE CONTROL: THE MIXED AIR DAMPERS, GAS HEATING STAGES, AND THE DX COOLING STAGES WILL MODULATE/CYCLE IN SEQUENCE TO MAINTAIN THE ZONE TEMPERATURE AT SETPOINT. ECONOMIZER DRY BULB SWITCHOVER: WHEN THE SHARED OUTSIDE AIR TEMPERATURE IS BELOW THE SWITCHOVER SETPOINT, THE ECONOMIZER WILL BE ENABLED. WHEN THE SHARED OUTSIDE AIR TEMPERATURE RISES ABOVE THE SWITCHOVER SETPOINT PLUS A DIFFERENTIAL, THE ECONOMIZER WILL BE DISABLED, NIGHT SETBACK/NIGHT SETUP: WHEN IN 'UNOCCUPIED" MODE, THE UNIT WILL CYCLE AS NECESSARY TO MAINTAIN THE NIGHT SETBACK ZONE TEMPERATURE AT SETPOINT. A DIFFERENTIAL PREVENTS THE UNIT FROM CYCLING EXCESSIVELY. SHUTDOWN: WHEN THE UNIT IS SHUTDOWN BY EITHER A STOP COMMAND OR SYSTEM SAFETY THE UNIT WILL BE SET AS FOLLOWS: SUPPLY FAN WILL BE OFF OUTSIDE AIR DAMPER WILL CLOSE RETURN AIR DAMPER WILL OPEN DX COOLING WILL BE OFF GAS HEAT WILL BE OFF City of Tukwila BUILDING DIVISION • RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER REV I S I ONS : onsulting Engineers ? 0201 Cedar Valley Road >u ite 120 .ynnwood, WA 98036 425) 774-3829 (425) 672-2084 FAX WELLS FARGO BANK -LOCKBOX TUKWILIA, WA SCHEDULES DATE : 03101113 SCALE: NTS DRAWN: SR CHECKED: RH pF WABti. 't fl.‘9-- -4192840 -11 ■ 12.028 t L 1.x8 LLj4x12 r 6x1 ... ,. x i; is Tat _1_- 24x20 -- NOTE: REMOVE ENTIRE EXISTING SYSTEM INCLUDING AIR HANDLER, ROOF TOP CONDENSING UNIT, VAV BOXES, DIFFUSERS, RETURN PLENUM GRILLES, EXISTING THERMOSTATS AND ANY OTHER ANCILLARY PARTS TO THIS SYSTEM. CONTRACTOR SHALL NOT ABANDON ANY EQUIPMENT IN PLACE, LEAVE RELIEF EXHAUST FAN AND CORRESPONDING DUCTWORK TO LOUVER IN PLACE. OWNER TO PROVIDE AND INSTALL CONTROL OF RELIEF EXHAUST FAN. ALL EXHAUST FAN SYSTEMS TO REMAIN. x--- - 1 6x �x x "1 -x- 20"0 X- X X:.1 f C) FIRST FLOOR PLAN HVAC DEMO 1/8=1-0 PLAN NORTH REVIEWED FOR CODE COMPLIANCE APPROVED SEP 18 2013 City of Tukwila BUILDING DIVISION 5g RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER RICE c0 Inc 7 Consulting Engineers 20201 Cedar Valley Road �iiitP 19n X CO 0 M •� j = c) O JWP ■ . � CO (.!) n .... ced J L.L. u - to <es .I J F- U) [e DATE : 03101113 SCALE : 114"•1'.0" DRAWN: SR CHECKED: RH �v r� WA f7f C' pF �5rr,�G '' 41928 M2.O 12.028 t s 8"0 CDL 200 CFM 8"0 CDL 200 CFM 8"0 CDL 200 CFM 8"0 CD 100 CF 8" O CDL 200 CFM 14x12 24x12_ (i 0 1 y 1_.._ 3) CIC 8'0 CDL 175 CFM 8"0 CDL 175 CFM 8"O CDL 200 CFM 8" CDL 200 CFM 175 CFM 8"0 CDL 175 CFM 12x12 1 8"0 CDL 200 CFIv 8"0 CDL 200, CFM 18x14 8"0 CDL 200 CFM 24x12 CGL I.. TRANSFER GRILLE (TYP. 4) \--TCS BASYS CONTROL PANEL 24x24` -CGL 1400 CFM 8"0 CDL 200 CFM 24x24 CGL 200 CFM 8"0 CDL 1 8„0 CDL 200 CFM , ij 200 CFM 24x24 CGL 1400,C M ! B 16X12j 8"$ CDL 200 CFM 8"0 CDL 1..:±713"0. 200 CFM 10"$ CDL 300 CFM 10"0 CDL 300 CFM 8"0 CDL 200 GEM . 1 16x12 !;` -24x12 CGL 100 CFM 8"0 CDL 200" CFM 8"0 CDL 200 CFM 8"0 CDL 200 CFM 8"0 CDL 200 CFM 8'0 CDL 200 CFM 8"0 CDL 200 CFM 8"0 CDL 150 CFIv 8"$ CDL 200 CFM 8"0 CDL 200 CFv1 18x114 8"0 CDL 200 CFM 8"0 CDL 200 CFIy1 111x10 24x24 CGL 1400 CFIv :. . REVIEWED FOR CODE COMPLIANCE APPROVED SEP 182013 City of Tukwila BUILDING DIVISION 20x18 UP I I ii.. TRANSITION AS NECESSARY TO CONNECT TO RTU -5 �. ( I I L. 112x12 1 • N,Nr.)t V 2424 CGL 1200 CFM )20117X 0 8"0 CDL 100 CFM 24x12 CGS 125 CFM 7_8 0 8"0 CDL 200 CFM 8"0 CDL 150 CFM 8"0 CDL:__'.. 200, CFM 8'0 CDL 150 CFM 8' N CDL 100 CFM 24x12 -CGS 100 CFM 8"0 CIL 200 CFM 8"0 CDL 200 CFM 14x12 NOTE: EXISTING EXHAUST FAN IN GARAGE TO REMAIN. FIRST FLOOR PLAN HVAC - NEW PLAN NORTH RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER ;onsulting Engineers ?0201 Cedar Valley Road suite 120 _ynn wood, WA 98036 425) 774-3829 (425) 672-2084 FAX WELLS FARGO BANK. LOCKBOX TUKWILIA, WA FIRST FLOOR PLAN HVAC -NEW DATE : 03101/13 SCALE : 118"=1'•0" DRAWN: SR CHECKED: RH At x 41928 0,s ■ 12.028 1-1/2" (1,020 MBH) PIPING DOWN TO GAS METER. (E)ET TO REMAIN.-._-.... 1I.:)LF 10 REMAIN. - 3/4" (120 MB 3/4" (180 MBH) MPG 3/4" (60 MBH) PAINT ALL GAS PIPING WITH WEATHER RESISTANT PAINT TO PROTECT BLACK STEEL GAS PIPING. 3/4" (60 MBH) 3/4" (60 MBH) REVIEWED FOR CODE COMPLIANCE APPROVED SEP 182013 City of Tukwila BUILDING DIVISION -PAINT ALL GAS PIPING WITH WEATHER RESISTANT PAINT TO PRQTECT BLACK STEEL GAS PIPING. " (120 MBH) 3/4" (240 MBH) 1" (360 MBH) MPG 3/4" (120 MBH) PLAN NORTH ROOF PLAN HVAC - NEW 1 /8"=1'-0" RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER r 1 REVISIONS 0 C� CC W V X L • N C O W 0 - I C0 U ( 0 N W 011)c CN'_' N LI00 N (n _1 ROOF PLAN HVAC - NEW DATE: SCALE: DRAWN: CHECKED: 03/01113 118"=1'-0" SR RH M-3.1 12-028 GAS PRESSURE REGULATOR INSULATING UNION GAS COCK (TYP.) PIPING RISER MUST NOT BE EMBEDED IN CONCRETE OR ASPHAULT M-4.0 SHUT—OFF VALVE GAS PIPE SUPPORT ROOF DECK GAS VALVE PRESSURE REDUCING VALVE SET FROM 2 PSI TO 7" W.C. PROVIDE GAS PIPE SUPPORT, SEE DETAIL 2/M-4 DRIP LEG ASSEMBLY SIZE LOW PRESSURE GAS LINE PER MANUFACTURER'S RECOMMENDATION. UNION REDUCER AS REQUIRED ROOF TOP EQUIPMENT GAS PIPING DETAIL M-4.0 SCALE: NTS KOSO EARTHQUAKE VALVE FINISHED GRADE N itl I1r rIr iTr u� T1=rl��ili�tj1llttll�hltll� TO BUILDING SUPPLY METER Lr 1ri l l 1J= II_i ,,lil,,;;ill 111-_ Ih :1-rr. 7 \GAS METER DETAIL I'Illi., oO NOTE: HORIZONTAL PIPING WITH EARTHQUAKE VALVE SHALL BE LEVEL AND SUBSTANTIALLY BRACED TO OUTSIDE WALL. EARTHQUAKE VALVE SHALL BE SPACED FROM THE OUTSIDE FACE OF THE WALL 4". WALL BRACING, SUPPORTS AND FASTENERS SHALL BE HOT DIPPED GALVANIZED STEEL. M-4:0/NTS SECURE PIPING TO SUPPORT WITH PIPE CLAMP C—PORT PIPE SUPPORT BY B—LINE GAS PIPE SUPPORT DETAIL _ SCALE: NTS PRE FABRICATED ROOF CURB SUPPLIED BY AC UNIT MANUFACTURER ROOF TOP AH UNIT SECURE DUCT TO CURB NAILER GASKET SUPPLIED WITH AH UNIT PRE FABRICATED CURB AC UNIT RAIL RIGID INSULATION FILLER TO SUIT INSULATED DUCTWORK— CEILING 14 GAUGE x 2" WIDE STRAP SHEET METAL SECURED TO ROOF TOP UNIT AND CURB FOR SEISMIC BRACING 2x ROOFING, EACH SIDE CANT STRIP, RIGID INSULATION AND FLASHING RTU CURB DETAIL METAL ROOF DECK ROOF DECK SEE STRUCTURAL DRAWINGS FOR ROOF SUPPORT AT CURB M-4.01 NTS REVIEWED FOR CODE COMPLIANCE APPRO. D SEP 18 2013 CiW of Tukwila tUILD1NG DIVISION FLEX DUCT, SAME SIZE AS DIFFUSER INLET (ROUND EQUIVALENT) SPIN -IN FITTING WITH VOLUME DAMPER— SUPPLY DIFFUSER 1 CEILING DIFFUSER DETAIL M-4.0 SCALE: NTS EZ—TRAP EXT -226 FLOAT SWITCH SLOPE ROOF 12x12x1 DRIP PAN ROOFTOP UNIT ((5CONDENSATE TRAP DETAIL vi -4.0 NTS N RECEIVED CITY OF TUKWILA AUG 2 9 2013 PERMIT CENTER REVISIONS :onsulting Engineers ?0201 Cedar Valley Road suite 120 _ynnwood, WA 98036 425) 774-3829 (425) 672-2084 FAX WELLS FARGO BANK -LOCKBOX TUKWILIA, WA DETAILS DATE : 03101113 SCALE: NTS DRAWN: SR CHECKED: RH c' p� WAsyr xf 41928 M -4.O 12.028