HomeMy WebLinkAboutPermit M13-170 - MAURICES - LANDLORD WORK - REPLACE ROOF TOP UNITMAURICES
LANDLORD WORK
1071 SO UTH CENTER MALL
M13-170
City o'ukwila
r
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206.431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 9202470010
Address: 1071 SOUTHCENTER MALL TUKW
Project Name: MAURICES - LANDLORD WORK
Permit Number:
Issue Date:
Permit Expires On:
M13-170
09/05/2013
03/04/2014
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
Contractor
ANDY ERVIN
814 S DISHMAN RD , SPOKANE WA 99213
ANDY@GENERALINDUSTRIESINC. C OM
AAA HEATING & AIR
PO BOX 13454 , SPOKANE WA 99213-3454
License No: AAAHEHA872NT
Phone: 509 939-8771
Phone: 509 443-3546
Expiration Date: 08/30/2015
DESCRIPTION OF WORK:
REMOVE ROOFTOP UNIT (1755 LBS) AND REPLACE WITH NEW ROOFTOP UNIT (1058 LBS)
Value of Mechanical: $16,007.25
Type of Fire Protection: SPRINKLERS/AFA
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complied
Fees Collected:
$399.75
International Mechanical Code Edition: 2012
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pres
construction or the performance of work.
back of this permit.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
Date: /-5-
This permit shall become mill and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
a,,... IRA(' nnn
M13.17(1 Printed: Og-05-2013
o
PERMIT CONDITIONS
Permit No. M13-170
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall :be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances
shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms,
bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE
GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that
the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests.
7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall
be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum
distance of 4 -inches shall be maintained above the controls with the strapping.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
Ml L_1 •�n
Pr,nforl• nQ_nF_7n14
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. JA) n 0
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Mom\ce4
Site Address:
Tenant Name: L%2S't-Pic/ c/
/nal/
``// King Co Assessor's Tax No.: l YV ! 4'I - o d
S�4Y�-Itt UQQ,Qfin' Suite Number: y(,S Floor:
PROPERTY OWNER
Name:
ett✓/`,✓
/
Address: 6/4/ S bi SA Incl..) ild
Name: 0e5, J
(1.4 id
EmailaAdv 06-e A ►t40/ S%r,lt.S inC . CO/h
Tukwila Business License No.: moue - aA T
Address: /0 g /
C0,44 -4C4-1,
/-4i) NL6t i
City: (24 ?N'/e
State ,
Zip:cm g
CONTACT PERSON - person receiving all project
communication
Name:
ett✓/`,✓
/
Address: 6/4/ S bi SA Incl..) ild
City:
a State:ZG Zip: 99.2/3
V
Phonerog,,939_62?, Fax: S-09 _ 2 -0/33/
EmailaAdv 06-e A ►t40/ S%r,lt.S inC . CO/h
New Tenant: ❑ Yes ❑ ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: 444 1�t4.l (L i /I / P
Address: 8./ ct
/ct s QrcSA4,44 (/R _/
City: OgaAt State: Ua /
Zip: 43
Phone-09,_?I9_87.7/ Fax:r69- ?).9. . y3.7a
Contr Reg No.: Exp Date:
Tukwila Business License No.: moue - aA T
Valuation of project (contractor's bid price): $ /6/ 007. v25"
Describe the scope of work in detail: Peti-tav(( k 0 d 200II-op %i n r t' Qhs ^s 11-61 i /Le
adoe 10 aft ;
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Fuel Type: Electric ❑
Gas (Q
Other:
H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Page I of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES-
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Date:
Day Telephone: -g77/
Mailing Address: J} 1 /9,5 gel 9920 6 k1 ?7
ty State Zip
H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 Ldoce
Revised: August 2011
bh
Page 2 of 2
City of atkwilar •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site. http./Avww ci Tukwila wa us
SET RECEIPT
RECEIPT NO: R13-02551
Initials: JEM
Payment Date: 09/05/2013
User ID: 1165 Total Payment: 529.05
Payee: PAUL J VELARDI (BY PHONE)
SET ID: 0905 SET NAME: AAA HEATING & AIR
SET TRANSACTIONS:
Set Member Amount
M13-170
M13-171
TOTAL:
319.80
209.25
319.00
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 529.05
TOTAL: 529.05
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.0 529.05
TOTAL: 529.05
INSPECTION RECORD
�.- Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3670
Permit Inspection Request Line (206) 431-2451
Project: Lot;
MINLI R 1 CA.5, - L��c� Lot;
of Inspection:
4--- 1 N A(„,
Address:
101 1 s C.
ril A 1 1.
Date Called:
Special Instructions:
Date Wanted:
q- I e._ I3
61...„n.:-
p.m.
Requester:
Phone No:
7`75 1-16 /- &2_6
3
Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
elitr11 i C 45 If k /.i 1 Aiki
kb -IF '1.,
•om- iy r}. 4 o v:,0.0 n O f r1 i.4 A kGtav'
1(k11-1 67‘ikifel..Wil ;S td0--
.1,K.) SO✓Vift' Akig OJ,iI tf°9-(1? a
TQ>v" -Cov- Sp Ao P 1071
InspcyortA 7 �\ CCU
D e:
1-19-1
1-1 INSPECTION FEE REQUIRED. Prior to next inspection, fee must be
id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
TRAM'
Model Number YSC120F3EMA**C000000001000000*0000000000
Customer :
Project :
Name : Y4C 1 1111
3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop
General
Unit function
Airflow
Fresh air selection
Cooling Entering DB
Ambient Temp
Voltage
DX cooling, gas heat
Unit efficiency
Convertible configuration Airflow Application
Econ -dry bulb 0-100% 3hp Tonnage
80.00F Cooling Entering WB
95.00F Heating capacity
208-230/60/3 Major design sequence
Standard efficiency
Downflow
10 Ton
67.00F
Medium gas heat 3ph
F - R -410A With Microchannel
DX Cooling, Gas Heat 3-10 Ton
Unit controls Electro mechanical controls
3ph
Refrigeration controls Frostat 3ph
/0 pelts Md tln
ec A''-'1
RECEIVED
CITY OF TUKWILA
SEP 0 5 2013
PERMIT CENTER
M1»1O .._
MANE
EVAPORATOR
SECTION ACCESS PANEL
CONDENSATE DRAIN (ALT)
3/4"-14 NPT DIA. HOLE
TOP PANEL
CONDENSER FAN
4 114"
1/2" NPT GAS CONNECTION
(80MBH &120MBH)
314" NPT GAS CONNECTION
(150MBH, 200M BH & 250MBH)
r,
THROUGH THE
BASE CONDENSATE
47 718"
4118"
r--
33"
--I
SUPPLY
L
11
1I /
NIT CONTROL WIRE 7B" DIA. HOLE
ERVICE GAUGE PORT ACCESS 1 318" DIA. HOLE
NIT POWER WIRE
ONDENSER COIL
ONTROL AND COMPRESSOR ACCESS PANEL
PACKAGED GAS / ELECTRICAL
ISOMETRIC VIEW
27578"�
RETURN
171/2"
PLAN VIEW UNIT
9 718"
17 1/2"
DIMENSION DRAWING
00
T
3 518"
i
32 1/4"
1.—'19 114"
CONDENSATE
08 518"—
I 4 3/4"
9 318" E -16 314" —� j k-3 7/8"
NOTES:
1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS.
2. VERIFYALL DIMENSIONS WITH INSTALLER DOCUMENTS
BEFORE INSTALLATION.
I
46 718
24 /2" 4
9 518
0
5 518"
0
0
CJ
PACKAGED GAS/ELECTRICAL
4114"-
5 518" --o-
7 58"
DIMENSION DRAWING
.b 53 1/4"
HORIZONTAL
AIR FLOW
Page 2
FRETURN
23718"
L
,
SUPPLY
00
T
3 518"
i
32 1/4"
1.—'19 114"
CONDENSATE
08 518"—
I 4 3/4"
9 318" E -16 314" —� j k-3 7/8"
NOTES:
1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS.
2. VERIFYALL DIMENSIONS WITH INSTALLER DOCUMENTS
BEFORE INSTALLATION.
I
46 718
24 /2" 4
9 518
0
5 518"
0
0
CJ
PACKAGED GAS/ELECTRICAL
4114"-
5 518" --o-
7 58"
DIMENSION DRAWING
.b 53 1/4"
HORIZONTAL
AIR FLOW
Page 2
3/4"-14 DIA HOLE
CONDENSATE DRAIN
27 5/8"
4 3/4"
ISOMETRIC -PACKAGED COOLING
Page 3
• TRANS'
ELECTRICAL / GENERAL DATA
'GENERAL c2X4xe)
HEATING PERFORMANCE
Model:
YSC120F
Oversized Motor
HEATING -GENERAL DATA
Unit Operating Voltage:
187-253
MCA: N/A
Unit Primary Voltage:
208
MFS: NIA
Heating Model: Medium
Unit Secondary Voltage
230
MCB: N/A
Heating Input (BTU): 200,0001140,000
Unit Hertz'
60
Heating Output (BTU): 160,0001112,000
Unit Phase:
3
No. Burners: 4
No. Stages 2
EER
11.3
Standard Motor
Field Installed Oversized Motor
Gas Inlet Pressure
MCA
49.6
MCA N/A
Natural Gas(Minrtvlix): 4.5/14
MFS:
60.0
MFS: N/A
LP (Min/Max) 10.0/14.0
MCB:
60.0
MCB: N/A
Gas Pipe Connection Size: 3/4"
INDOOR MOTOR
Standard Motor
Oversized Motor
Field Installed Oversized Motor
Number.
1
Number:
N/A
Number. N/A
Horsepower.
3.8
Horsepower
N/A
Horsepower: NIA
Motor Speed (RPM):
--
Motor Speed (RPM)
N/A
Motor Speed (RPM) N/A
Phase3
Phase
N A
Phase N/A
Full LoadAmps:
8.5-8.5
Full Load Mrps:
N/A
Full Load Amps N/A
Locked Rotor Amps:
-
Locked Rotor Amps:
NIA
Locked Rotor Amps: NIA
COMPRESSOR
Circuit 1/2
OUTDOOR MOTOR
Number.
2
Number: 1
Horse power:
4.8/3.7
FI orsepower. 0.75
Phase:
3
Motor Speed (RPM): 1100
Rated Load Amps:
20.5/16.0
Phase: 1
Locked Rotor Amps:
155.0/91.0
Full Load Amps: 4.0
Locked Rotor Mrpm 9A
POWER EXHAUST ACCESSORY (3)
FILTERS
REFRIGERANT (2)
(Field Installed Power Exhaust)
Type R-410
Phase:
NIA
Type:
Throwaway
FadoryCharge
Horsepower:
N/A
Furnished:
Yes5.5
lb
Circuit#1
Motor Speed (RPM):
Full Load Amps:
N/A
N/A
Number
Recommended
4
20"x25">:2"
Circuit #2 4.2 lb
Locked Rotor Amps:
N/A
NOTES:
1. Maximum (HACR) Circuit Breaker slang is for installations In the United States only.
2.R efrigerant charge is an approximate value. Fora more precise value, see unit nameplate and service instructions.
3. Value does not include Power Exhaust Accessory.
4. Value includes oversized motor.
5. Value does not indude Power Exhaust Accessory.
6. EER is rated at AHRI conditions and in accordance vtith DOE test procedures.
Page 4
•TRANF
c)\,
d
0
PACKAGED GAS / ELECTRICAL
CORNER WEIGHT
INSTALLED ACCESSORIES NET WEIGHT DATA
NOTE:
1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY.
2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT.
3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORYWEIGHT. TO OBTAIN TOTAL
WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT.
4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS.
PACKAGED GAS / ELECTRICAL
RIGGING AND CENTER OF GRAVITY
Page 5
ACCESSORY
WEIGHTS
ECONOMIZER
36.0 lb
MOTORIZED OUTSIDE AIR DAMPER
MANUAL OUTSIDE AIR DAMPER
BAROMETRIC RELIEF
OVERSIZED MOTOR
BELT DRIVE MOTOR
POWER EXHAUST
THROUGHT THE BASE ELECTRICAL/GAS(FIOPS)
UNIT MOUNTED CIRCUIT BREAKER (FIOPS)
UNIT MOUNTED DISCONNECT (FIOPS)
POWERED CONVENIENCE OUTLET (FIOPS)
HINGED DOORS (FIOPS)
HAIL GUARD
SMOKE DETECTOR, SUPPLY/RETURN
NOVAR CONTROL
STAINLESS STEEL HEAT EXCHANGER
REHEAT
ROOF CURES
BASIC UNIT WEIGHTS
CORNER WEIGHTS
CENTER OF GRAVITIY
SHIPPING
NET
Ae
345.0 lb
CO
258.OIb
(E) LENGHT
(F)WIDTH
1156.0 lb
to1,058,;O,Ib.
O
242.0 lb
0
213.0 lb
41"
23"
NOTE:
1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY.
2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT.
3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORYWEIGHT. TO OBTAIN TOTAL
WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT.
4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS.
PACKAGED GAS / ELECTRICAL
RIGGING AND CENTER OF GRAVITY
Page 5
CLEARANCE 36"
CLEARANCE 48"
DOWN FLOW CLEARANCE 36"
HORIZONTAL CLEARANCE 18"
ROOF OPENING
UNIT OUTLINE
CLEARANCE 36"
PACKAGED GAS/ELECTRIC
CLEARANCE
46"
46
88 518"
CLEARANCE FROM TOP OF UNIT 72"
53 1/4"
PACKAGED GAS / ELECTRIC
DOWNFLOW TYPICAL ROOF OPENING
Page 6
T\
0
CONOMIZER HOOD
CONOMIZER HOOD
I ( 00 l
7-
00
ACCESSORY- ECONOMIZER HOOD
16 314"
6 716"
Page 7
MINE'
General
The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with
microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall
be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100
percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit
shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air
Conditioners.
Casing
Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with
a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet
construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by
removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be
insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch,
foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the
perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the
condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the
unit.
Unit Top
The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra
strength and enhances water removal from unit top.
Filters
Throwaway filters shall be standard on all units. Optional 2 -inch MERV 8 and MERV 13 filters shall also be available.
Compressors
All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall
have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll
compressors.
Crankcase heaters shall be included on 6-10 ton units.
Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are
available on 71/2-10 ton models and allow for efficient cooling utilizing 3 -stages of compressor operation for all high efficiency models.
Indoor Fan
The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092,102, 120E). Plenum fan design shall include a
backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable
speed adjustment potentiometer located in the control box. 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional
motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1 -phase or high efficiency 3-phase) have multispeed,
direct drive motors. All 6-81 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick -
adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 71-81/2 (high efficiency) have variable speed
direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT).
Outdoor Fans
The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be
permanently lubricated and shall have built-in thermal overload protection.
Evaporator and Condenser Coils
Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser
coil is standard for the T/YSC 10 ton models and 7'/2 ton high efficiency models. The microchannel type condenser coil is not offered on the 71/2
ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat
transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which
leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. All -aluminum construction
improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better
fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested
at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall
Page 8
be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A
removable, reversible, double -sloped condensate drain pan with through the base condensate drain is standard.
Controls
Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide
an external location for mounting a fused disconnect device. A choice: of microprocessor or electromechanical controls shall be available.
Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating
decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate
temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti -short
cycle timing and time delay between compressors to provide a higher level of machine protection. 24 -volt electromechanical control circuit shall
include control transformer and contactor
High Pressure Control
All units include High Pressure Cutout as standard.
Phase monitor
Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase
reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will
automatically reset from a fault condition.
Refrigerant Circuits
Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as
standard. An area shall be provided for replacement suction line driers.
Gas Heating Section
The heating section shall have a progressive tubular heat exchanger design using stainless steel burners
and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing
tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for
20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the
thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California
requirement for low NOx emissions (Gas/Electric Only).
Economizer
This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers,
minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall
provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle.
Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping
position and shall be moved to the operating position by the installing contractor.
Frostat
This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will
need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.)
Page 9
ADAPTER CURB FOR TRANE
TSC/YSC072-120E & THC/Y'HC048-072E & WSC060-092E
ADAPTER CURB
INSTRUCTIONS;
1. REMOVE OLD A/C UNIT.
2. APPLY 1/4" x 1 1/4" GASKETING.
3. INSTALL & SECURE ADAPTER CURB
ON EXISTING CURB AS REQUIRED BY
LOCAL BUILDING CODE.
4. APPLY 1/4" x 1 1/4" GASKETING ON ADAPTER CURB.
5. INSTALL & SECURE NEW NC UNIT ON ADAPTER CURB AS
REQUIRED BY LOCAL BUILDING CODE.
EXISTING TRANE UNCI
SACA/SFCA - 100
SACC/SFCB - C10/11
BTC/BYC130G
STANDARDJ,EA.TU.RES;
• HEAVY GA. GALV. STEEL CONSTRUCTION
• FULLY INSULATED WITH 1" -1.5 LB.
DENSITY INSULATION
1/4" x 1 1/4' GASKETING
SHIPPED FULLY ASSEMBLED
SUPPLY AND RETURN DUCT
CHAMBERS INCLUDED
•
PRODUCT SUBMITTAL
QUOTE #
signature required prior to production.
Sign here:
Plenums Inc. Model TC43ACACA100
Manufacturers Equip
Approved
Date
0 CHANGE WITHOUT NOTICE
FORM: TC43ACACA I00.1ndd.03/0312011
• Te 15 TONS
reN
U
'risme In#SFc-a
0
..
1
i
3gi
gr. 1s
17 12
i la
i IS
ism
6 ghs
RN I51
1115't
I IQ
I le
IQo
1c31
.:R I:
I I !M
I Irz
1 Ir=
1$0
gdi
RR IS
RaVa
:88
SS88
RSSi
M111
W
CR IS
NR9a
R7Sa
.aa
sag
ggf
RR is
NSS:
RAS
vas
5387
in
82:x
Saris
8S§
88g
s gg
g 21n3
225_,N
53aaN
2:53
SNSS
Rsn
Evi7m8t
StI
NI
7e3ga:
wr,a
Rea
�R
3li
853$8
88522
8Rg
iCRg
5SF1§
R d 3W
sesta
AS.oN
822
SNSS
785SEC
1S
:AIM
Sraf:aa
NgtE
QRZ
�{r
O^ mtiz
_7'
22kt
�ll
FiR7e3
2P2
OR
7a
LLS
N73
3s lty
lest
gldg
11
F
I IR29I I7J%
.4/
L1.tt
y
SS2 I I ISSi I lb.
V
3$A
I I�87R I I I I I
53NR
R9R
128Sagittil
Sag
Y
SRC
y mRRSSSt I I I I I
87A
11
RARStaRASaa
SCR
V
0g§§9NN§f'l
ass
708:
ill
1a797a8Nn38138
;i432
RRR
161
RBR9RN872gR
xcs
161
IC8888a8888
Rag
ffi9'a
11111
5
Ili
ggQQ gg yi
III
111
gldg
SCR
SCR
SCR
8:8
«87
?RR
53NR
R9R
$779
Sag
gdr
SRC
R797C
87A
ns*
222
SCR
8RN
2779
ass
708:
ill
2'....-
;i432
RRR
SCR
7--SS3
xcs
cRiO
8798
Rag
ffi9'a
11111
Ili
/II
III
111
i i
111
Ili
111111
1
§i§
glg
I pi
8x3
ggi
I
§z1E
ggg
8�8
ggg
33P?
ggg
1 I
StI
NI
OP3.7a
IR
FES
iglu
RitXS
lugui
assn
tifi
0
r
Contractors or Tradespeople Prin.-Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with Lal to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name AAA HEATING Et AIR
Phone 5094433546
Address Po Box 13454
Suite/Apt.
City Spokane
State WA
Zip 992133454
County Spokane
Business Type Corporation
Parent GENERAL INDUSTRIES
Company INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration
Date
Suspend Date
Specialty 1
600622321
Active
AAAHEHA872NT
Construction Contractor
8/30/2013
8/30/2015
Heating/Vent/Air-Conditioning And Refrig
(Hvac/R)
Specialty 2 Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
GENERII147MTGENERAL
INDUSTRIES INC
Construction
Contractor
General
Unused
7/30/1986
12/14/2013
Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
VELARDI, PAUL JOSEPH
President
08/30/2013
BACHELLER, DOUGLAS ORVIN
Vice President
08/30/2013
Bond Information
Page 1 of 1
Bond Bond Company Name Bond Account Number
Suretec Insurance
Company
1
5166978
Effective Date Expiration Date
08/28/2013 Until Cancelled
Cancel Date
Impaired Date
Bond Amount
Received Date
$6,000.00
08/30/2013
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date Cancel Date Impaired Date
Amount
Received Date
1
American Fire
a Casualty Co
BKA1354292612
12/04/2012
12/04/2013
$1,000,000.00
08/30/2013
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx 09/05/2013