HomeMy WebLinkAboutPermit M13-170 - MAURICES - LANDLORD WORK - REPLACE ROOF TOP UNITMAURICES LANDLORD WORK 1071 SO UTH CENTER MALL M13-170 City o'ukwila r Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206.431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 1071 SOUTHCENTER MALL TUKW Project Name: MAURICES - LANDLORD WORK Permit Number: Issue Date: Permit Expires On: M13-170 09/05/2013 03/04/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor ANDY ERVIN 814 S DISHMAN RD , SPOKANE WA 99213 ANDY@GENERALINDUSTRIESINC. C OM AAA HEATING & AIR PO BOX 13454 , SPOKANE WA 99213-3454 License No: AAAHEHA872NT Phone: 509 939-8771 Phone: 509 443-3546 Expiration Date: 08/30/2015 DESCRIPTION OF WORK: REMOVE ROOFTOP UNIT (1755 LBS) AND REPLACE WITH NEW ROOFTOP UNIT (1058 LBS) Value of Mechanical: $16,007.25 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied Fees Collected: $399.75 International Mechanical Code Edition: 2012 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pres construction or the performance of work. back of this permit. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: /-5- This permit shall become mill and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. a,,... IRA(' nnn M13.17(1 Printed: Og-05-2013 o PERMIT CONDITIONS Permit No. M13-170 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall :be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Ml L_1 •�n Pr,nforl• nQ_nF_7n14 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. JA) n 0 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Mom\ce4 Site Address: Tenant Name: L%2S't-Pic/ c/ /nal/ ``// King Co Assessor's Tax No.: l YV ! 4'I - o d S�4Y�-Itt UQQ,Qfin' Suite Number: y(,S Floor: PROPERTY OWNER Name: ett✓/`,✓ / Address: 6/4/ S bi SA Incl..) ild Name: 0e5, J (1.4 id EmailaAdv 06-e A ►t40/ S%r,lt.S inC . CO/h Tukwila Business License No.: moue - aA T Address: /0 g / C0,44 -4C4-1, /-4i) NL6t i City: (24 ?N'/e State , Zip:cm g CONTACT PERSON - person receiving all project communication Name: ett✓/`,✓ / Address: 6/4/ S bi SA Incl..) ild City: a State:ZG Zip: 99.2/3 V Phonerog,,939_62?, Fax: S-09 _ 2 -0/33/ EmailaAdv 06-e A ►t40/ S%r,lt.S inC . CO/h New Tenant: ❑ Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: 444 1�t4.l (L i /I / P Address: 8./ ct /ct s QrcSA4,44 (/R _/ City: OgaAt State: Ua / Zip: 43 Phone-09,_?I9_87.7/ Fax:r69- ?).9. . y3.7a Contr Reg No.: Exp Date: Tukwila Business License No.: moue - aA T Valuation of project (contractor's bid price): $ /6/ 007. v25" Describe the scope of work in detail: Peti-tav(( k 0 d 200II-op %i n r t' Qhs ^s 11-61 i /Le adoe 10 aft ; Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas (Q Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES- Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Date: Day Telephone: -g77/ Mailing Address: J} 1 /9,5 gel 9920 6 k1 ?7 ty State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 Ldoce Revised: August 2011 bh Page 2 of 2 City of atkwilar • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site. http./Avww ci Tukwila wa us SET RECEIPT RECEIPT NO: R13-02551 Initials: JEM Payment Date: 09/05/2013 User ID: 1165 Total Payment: 529.05 Payee: PAUL J VELARDI (BY PHONE) SET ID: 0905 SET NAME: AAA HEATING & AIR SET TRANSACTIONS: Set Member Amount M13-170 M13-171 TOTAL: 319.80 209.25 319.00 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 529.05 TOTAL: 529.05 ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.0 529.05 TOTAL: 529.05 INSPECTION RECORD �.- Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3670 Permit Inspection Request Line (206) 431-2451 Project: Lot; MINLI R 1 CA.5, - L��c� Lot; of Inspection: 4--- 1 N A(„, Address: 101 1 s C. ril A 1 1. Date Called: Special Instructions: Date Wanted: q- I e._ I3 61...„n.:- p.m. Requester: Phone No: 7`75 1-16 /- &2_6 3 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: elitr11 i C 45 If k /.i 1 Aiki kb -IF '1., •om- iy r}. 4 o v:,0.0 n O f r1 i.4 A kGtav' 1(k11-1 67‘ikifel..Wil ;S td0-- .1,K.) SO✓Vift' Akig OJ,iI tf°9-(1? a TQ>v" -Cov- Sp Ao P 1071 InspcyortA 7 �\ CCU D e: 1-19-1 1-1 INSPECTION FEE REQUIRED. Prior to next inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. TRAM' Model Number YSC120F3EMA**C000000001000000*0000000000 Customer : Project : Name : Y4C 1 1111 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop General Unit function Airflow Fresh air selection Cooling Entering DB Ambient Temp Voltage DX cooling, gas heat Unit efficiency Convertible configuration Airflow Application Econ -dry bulb 0-100% 3hp Tonnage 80.00F Cooling Entering WB 95.00F Heating capacity 208-230/60/3 Major design sequence Standard efficiency Downflow 10 Ton 67.00F Medium gas heat 3ph F - R -410A With Microchannel DX Cooling, Gas Heat 3-10 Ton Unit controls Electro mechanical controls 3ph Refrigeration controls Frostat 3ph /0 pelts Md tln ec A''-'1 RECEIVED CITY OF TUKWILA SEP 0 5 2013 PERMIT CENTER M1»1O .._ MANE EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE TOP PANEL CONDENSER FAN 4 114" 1/2" NPT GAS CONNECTION (80MBH &120MBH) 314" NPT GAS CONNECTION (150MBH, 200M BH & 250MBH) r, THROUGH THE BASE CONDENSATE 47 718" 4118" r-- 33" --I SUPPLY L 11 1I / NIT CONTROL WIRE 7B" DIA. HOLE ERVICE GAUGE PORT ACCESS 1 318" DIA. HOLE NIT POWER WIRE ONDENSER COIL ONTROL AND COMPRESSOR ACCESS PANEL PACKAGED GAS / ELECTRICAL ISOMETRIC VIEW 27578"� RETURN 171/2" PLAN VIEW UNIT 9 718" 17 1/2" DIMENSION DRAWING 00 T 3 518" i 32 1/4" 1.—'19 114" CONDENSATE 08 518"— I 4 3/4" 9 318" E -16 314" —� j k-3 7/8" NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFYALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. I 46 718 24 /2" 4 9 518 0 5 518" 0 0 CJ PACKAGED GAS/ELECTRICAL 4114"- 5 518" --o- 7 58" DIMENSION DRAWING .b 53 1/4" HORIZONTAL AIR FLOW Page 2 FRETURN 23718" L , SUPPLY 00 T 3 518" i 32 1/4" 1.—'19 114" CONDENSATE 08 518"— I 4 3/4" 9 318" E -16 314" —� j k-3 7/8" NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFYALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. I 46 718 24 /2" 4 9 518 0 5 518" 0 0 CJ PACKAGED GAS/ELECTRICAL 4114"- 5 518" --o- 7 58" DIMENSION DRAWING .b 53 1/4" HORIZONTAL AIR FLOW Page 2 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" 4 3/4" ISOMETRIC -PACKAGED COOLING Page 3 • TRANS' ELECTRICAL / GENERAL DATA 'GENERAL c2X4xe) HEATING PERFORMANCE Model: YSC120F Oversized Motor HEATING -GENERAL DATA Unit Operating Voltage: 187-253 MCA: N/A Unit Primary Voltage: 208 MFS: NIA Heating Model: Medium Unit Secondary Voltage 230 MCB: N/A Heating Input (BTU): 200,0001140,000 Unit Hertz' 60 Heating Output (BTU): 160,0001112,000 Unit Phase: 3 No. Burners: 4 No. Stages 2 EER 11.3 Standard Motor Field Installed Oversized Motor Gas Inlet Pressure MCA 49.6 MCA N/A Natural Gas(Minrtvlix): 4.5/14 MFS: 60.0 MFS: N/A LP (Min/Max) 10.0/14.0 MCB: 60.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. 1 Number: N/A Number. N/A Horsepower. 3.8 Horsepower N/A Horsepower: NIA Motor Speed (RPM): -- Motor Speed (RPM) N/A Motor Speed (RPM) N/A Phase3 Phase N A Phase N/A Full LoadAmps: 8.5-8.5 Full Load Mrps: N/A Full Load Amps N/A Locked Rotor Amps: - Locked Rotor Amps: NIA Locked Rotor Amps: NIA COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number. 2 Number: 1 Horse power: 4.8/3.7 FI orsepower. 0.75 Phase: 3 Motor Speed (RPM): 1100 Rated Load Amps: 20.5/16.0 Phase: 1 Locked Rotor Amps: 155.0/91.0 Full Load Amps: 4.0 Locked Rotor Mrpm 9A POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R-410 Phase: NIA Type: Throwaway FadoryCharge Horsepower: N/A Furnished: Yes5.5 lb Circuit#1 Motor Speed (RPM): Full Load Amps: N/A N/A Number Recommended 4 20"x25">:2" Circuit #2 4.2 lb Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker slang is for installations In the United States only. 2.R efrigerant charge is an approximate value. Fora more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not indude Power Exhaust Accessory. 6. EER is rated at AHRI conditions and in accordance vtith DOE test procedures. Page 4 •TRANF c)\, d 0 PACKAGED GAS / ELECTRICAL CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORYWEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY Page 5 ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY/RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURES BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET Ae 345.0 lb CO 258.OIb (E) LENGHT (F)WIDTH 1156.0 lb to1,058,;O,Ib. O 242.0 lb 0 213.0 lb 41" 23" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORYWEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY Page 5 CLEARANCE 36" CLEARANCE 48" DOWN FLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE 46" 46 88 518" CLEARANCE FROM TOP OF UNIT 72" 53 1/4" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING Page 6 T\ 0 CONOMIZER HOOD CONOMIZER HOOD I ( 00 l 7- 00 ACCESSORY- ECONOMIZER HOOD 16 314" 6 716" Page 7 MINE' General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R -410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather -resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil -faced, fire -retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil -faced, closed -cell insulation. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double -hemmed and gasket -sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2 -inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct -drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Crankcase heaters shall be included on 6-10 ton units. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 71/2-10 ton models and allow for efficient cooling utilizing 3 -stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120E, T/YHC092,102, 120E). Plenum fan design shall include a backward -curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3-5 ton units (standard efficiency 3-phase or high efficiency 3-phase with optional motor) are belt driven, FC centrifugal fans with adjustable motor sheaves. 3-5 ton units (1 -phase or high efficiency 3-phase) have multispeed, direct drive motors. All 6-81 ton units (standard efficiency) shall have belt drive motors with an adjustable idler -arm assembly for quick - adjustment to fan belts and motor sheaves. All motors shall be thermally protected. All 10 tons and 71-81/2 (high efficiency) have variable speed direct drive motors. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct -drive, statically and dynamically balanced, draw -through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The microchannel type condenser coil is standard for the T/YSC 10 ton models and 7'/2 ton high efficiency models. The microchannel type condenser coil is not offered on the 71/2 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube -to -fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better compressor reliability. Compact all -aluminum microchannel coils also help to reduce the unit weight. All -aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall Page 8 be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double -sloped condensate drain pan with through the base condensate drain is standard. Controls Unit shall be completely factory -wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice: of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized microprocessor shall provide anti -short cycle timing and time delay between compressors to provide a higher level of machine protection. 24 -volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory -installed as standard. An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane (field -installed kit) and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Frostat This option is to be utilized as a safety device. The Frostat opens when temperatures on the evaporator coil fall below 10°F. The temperature will need to rise to 50°F before closing. This option should be utilized in low airflow or high outside air applications. (Cooling with Electric Heat Only.) Page 9 ADAPTER CURB FOR TRANE TSC/YSC072-120E & THC/Y'HC048-072E & WSC060-092E ADAPTER CURB INSTRUCTIONS; 1. REMOVE OLD A/C UNIT. 2. APPLY 1/4" x 1 1/4" GASKETING. 3. INSTALL & SECURE ADAPTER CURB ON EXISTING CURB AS REQUIRED BY LOCAL BUILDING CODE. 4. APPLY 1/4" x 1 1/4" GASKETING ON ADAPTER CURB. 5. INSTALL & SECURE NEW NC UNIT ON ADAPTER CURB AS REQUIRED BY LOCAL BUILDING CODE. EXISTING TRANE UNCI SACA/SFCA - 100 SACC/SFCB - C10/11 BTC/BYC130G STANDARDJ,EA.TU.RES; • HEAVY GA. GALV. STEEL CONSTRUCTION • FULLY INSULATED WITH 1" -1.5 LB. DENSITY INSULATION 1/4" x 1 1/4' GASKETING SHIPPED FULLY ASSEMBLED SUPPLY AND RETURN DUCT CHAMBERS INCLUDED • PRODUCT SUBMITTAL QUOTE # signature required prior to production. Sign here: Plenums Inc. Model TC43ACACA100 Manufacturers Equip Approved Date 0 CHANGE WITHOUT NOTICE FORM: TC43ACACA I00.1ndd.03/0312011 • Te 15 TONS reN U 'risme In#SFc-a 0 .. 1 i 3gi gr. 1s 17 12 i la i IS ism 6 ghs RN I51 1115't I IQ I le IQo 1c31 .:R I: I I !M I Irz 1 Ir= 1$0 gdi RR IS RaVa :88 SS88 RSSi M111 W CR IS NR9a R7Sa .aa sag ggf RR is NSS: RAS vas 5387 in 82:x Saris 8S§ 88g s gg g 21n3 225_,N 53aaN 2:53 SNSS Rsn Evi7m8t StI NI 7e3ga: wr,a Rea �R 3li 853$8 88522 8Rg iCRg 5SF1§ R d 3W sesta AS.oN 822 SNSS 785SEC 1S :AIM Sraf:aa NgtE QRZ �{r O^ mtiz _7' 22kt �ll FiR7e3 2P2 OR 7a LLS N73 3s lty lest gldg 11 F I IR29I I7J% .4/ L1.tt y SS2 I I ISSi I lb. V 3$A I I�87R I I I I I 53NR R9R 128Sagittil Sag Y SRC y mRRSSSt I I I I I 87A 11 RARStaRASaa SCR V 0g§§9NN§f'l ass 708: ill 1a797a8Nn38138 ;i432 RRR 161 RBR9RN872gR xcs 161 IC8888a8888 Rag ffi9'a 11111 5 Ili ggQQ gg yi III 111 gldg SCR SCR SCR 8:8 «87 ?RR 53NR R9R $779 Sag gdr SRC R797C 87A ns* 222 SCR 8RN 2779 ass 708: ill 2'....- ;i432 RRR SCR 7--SS3 xcs cRiO 8798 Rag ffi9'a 11111 Ili /II III 111 i i 111 Ili 111111 1 §i§ glg I pi 8x3 ggi I §z1E ggg 8�8 ggg 33P? ggg 1 I StI NI OP3.7a IR FES iglu RitXS lugui assn tifi 0 r Contractors or Tradespeople Prin.-Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AAA HEATING Et AIR Phone 5094433546 Address Po Box 13454 Suite/Apt. City Spokane State WA Zip 992133454 County Spokane Business Type Corporation Parent GENERAL INDUSTRIES Company INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 600622321 Active AAAHEHA872NT Construction Contractor 8/30/2013 8/30/2015 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status GENERII147MTGENERAL INDUSTRIES INC Construction Contractor General Unused 7/30/1986 12/14/2013 Active Business Owner Information Name Role Effective Date Expiration Date VELARDI, PAUL JOSEPH President 08/30/2013 BACHELLER, DOUGLAS ORVIN Vice President 08/30/2013 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Suretec Insurance Company 1 5166978 Effective Date Expiration Date 08/28/2013 Until Cancelled Cancel Date Impaired Date Bond Amount Received Date $6,000.00 08/30/2013 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 American Fire a Casualty Co BKA1354292612 12/04/2012 12/04/2013 $1,000,000.00 08/30/2013 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/05/2013