HomeMy WebLinkAboutPermit M13-173 - 16000 CHRISTENSEN BUILDING - SUITES 100, 201 & 304 ALTERATIONBUTTES 100, 201 & 304 16000 CHRISTENSEN RD M13-173 City oilitukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049077 Address: 16000 CHRISTENSEN RD TUKW Project Name: SUITES 100, 201 & 304 Permit Number: M13-173 Issue Date: 09/18/2013 Permit Expires On: 03/17/2014 Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE , PALO ALTO CA 94301 Contact Person: Name: MIKE RICHEY Address: PO BOX 33326 , SHORELINE WA 98133 Email: MIKERICHEY2@COMCAST.NET Contractor: Name: MJR MECHANICAL LLC Address: PO BOX 33326 , SEATTLE WA 98133 Contractor License No: MJRMEML913R8 Phone: 206 714-6374 Phone: 206-714-6374 Expiration Date: 12/28/2013 DESCRIPTION OF WORK: REPLACE (2) ELECTRIC DUCT HEATERS, REPLACE (1) VAV BOX, ADD 30 LF DUCTWORK, AND RELOCATE DIFFUSERS AND GRILLES Value of Mechanical: $5,690.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: .. Fees Collected: $261.56 International Mechanical Code Edition: 2012 7 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: 1 t l �/ (3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. n..:-�..J. nn 10 0040 PERMIT CONDITIONS Permit No. M13-173 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. Jnr.• IMC -4/10 M13-173 Printed: 09-18-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www."l_ukw.ilaaW'A.gov Mechanical Permit No. Avy n Project No. Date Application Accepted: Date Application Expires: ollto Atto (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 2532049078 Site Address: 16000 Christensen Road, Building 2 Suite Number: Floor: 1, 2 & 3 Tenant Name: Yellow Pages, Suite 100, Suite 201 & Suite 304 PROPERTY OWNER Name: Unico Properties Address: 16040 Christensen Road, Suite 100 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Mike Richey Address: PO Box 33326 Address: PO Box 33326 Phone: (206) 714-6374 Fax: (206) 533-0628 City: Shoreline State: WA Zip: 98133 Phone: (206) 714-6374 Fax: (206) 533-0628 Email: mikerichey2@comcast.net New Tenant: ® Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: MJR Mechanical Address: PO Box 33326 City: Shoreline State: WA Zip: 98133 Phone: (206) 714-6374 Fax: (206) 533-0628 Contr Reg No.: MJRMEML913R8 Exp Date: 12/28/2013 Tukwila Business License No.: BUS -0992692 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Replace 2 electric duct heaters, replace 1 VAV box, @30 LF ductwork, relocate diffusers and grilles. 5,690 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ® Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications \Mechanical Permit Application Revised it -9.1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE f OR HORIZED AGENT: Signature: Print Name: Mike Richey Mailing Address: PO Box 33326 H:\Applications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 0-9-I I.docx Revised: August 2011 bh Date: 09/10/2013 Day Telephone: (206) 714-6374 Shoreline WA 98133 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Qov Parcel No.: 2523049077 Address: 16000 CHRISTENSEN RD TUKW Suite No: Applicant: SUITES 100, 201 & 304 RECEIPT Permit Number: M13-173 Status: PENDING Applied Date: 09/10/2013 Issue Date: Receipt No.: R13-02591 Initials: JEM User ID: 1165 Payment Amount: $261.56 Payment Date: 09/10/2013 12:13 PM Balance: $0.00 Payee: MJR MECHANICAL LLC, MICHAEL JAMES RICHE,T TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 121842 ACCOUNT ITEM LIST: Description 261.56 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 209.25 000.345.830 52.31 Total: $261.56 .r.,,.• oe..ec..� na Printari- n9.1n-2013 ,.- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Mt3-,93 -6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t ,_- 1 tX t✓ 1 304 5Li ( TAi ype � Ie/s 1 n; 4eA Address: 1-4 i Ro 000 (,kt rsi-ens tisi Date Called: Special Instructions: Date Wanted: �`'� -13 p.m' P• 'Requester: ll'Ione No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: I pectora -rate,: 0 _14 4 13 I I 8 REINSPECTION FEE"REQ RED. Prior to next inspection, fee must be paid at 6300 Southcenter id.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Typ AL1 I+� S 10 0 17_011 ?C)1 of Ins ction: t i ON GN -1.-Nj Address: la to aped: Wanted:_ L(! 1 -, P•Cr,. Special Instructions: Df;'" 2 6S � � � Sus ;�,,rN' 0-C. � . egretbeS Date Requesstellr: �Phone N �'�1� -C,37� proved per applicable codes. Corrections required prior to approval. COMMENTS: n RE NSP CTION FEE REQUIRE Prior to n xt inspection. fee must be pail at 6 00 Southcenter Blvd., uite 100. *=11 to schedule reinspection. VAV TERMINAL BOX SCHEDULE UNIT NO. VAV BOX MODEL NO. INLET SIZE COOL CFM MIN CFM HEATER NOTES KW AT CFM VOLTS/PH E106 VAV Reheat 10 Inch 620 10.9 45 380 Ex zone & Heater. Disable 1 stage of heat. E107 VAV Reheat 8 Inch 700 6.2 45 435 New zone & Heater, See Note #1 E108 VAV Reheat 8 Inch 540 4.4 45 310 Ex zone & Heater E110 VAV Reheat 12 Inch 654 6.4 45 450 Ex zone & Heater W205 VAV Reheat 8 Inch 701 3.6 45 253 Ex zone & Heater W206 VAV Reheat 8 Inch 800 3.5 45 253 Ex zone / New Heater, See Note#2 W207 VAV Reheat ??? NA NA Ex Zone Unused, No work Serves adjacent space. W210 VAV Reheat ??? 460 Verify Ex Zone in adjacent space 305 VAV Reheat 8 Inch 3.6 45 253 Ex zone & Heater 306 VAV Reheat 8 Inch 3.5 45 253 Ex zone & Heater ??? VAV Reheat Verify Ex Zone in adjacent space Note: 1, New Titus DESV Cooling Only VAV box. New Duct Heater. "Warren CBK" 6.4 KW ® 480V-3 Ph. 2 Stage 24V controls, Duct size: 12"w x 10" high. 2, Duct Heater. "Warren CBK" 5.8 KW 0 277V-3 Ph. REVISIONS No changes shalt be made to the scope cf 1°ror€t without prior approval of Tz °'ca'='i;a Building Division. V vns will require a new plan submittal ;; ac udt; du'jitionai plan reviewfes DR VIFIGIrstiDEX- M-0 TM -1 TM -2 TM -3 2 Stage 24V controls, Duct size: 14"w x 10" high. COVER SHEET, SCHEDULES, LEGEND, NOTES Yellow Pages TI HVAC Plan Suite 201 Market Ready (No Tenant) Suite 304 Market Ready (No Tenant) FILE COP■ Permit No. plef review approval is subject to errors and omissions. 1, of construction documents does not author:. 3 adopted• codeor ordinance. Recti:tit 04:04: ckri� Field + +I and ., is ed9 d I Wadi 1111111111 E CONSTRUCTION NOTE, TO EXISTING THERMOSTAT LOCATION. RO T RELOCATED THERMOSTAT LOCATION. 'D' INDICATES DEMO EXISTING DIFFUSER/GRILLES. 'E' INDICATES EXISTING S/A DIFFUSER & R/A GRILLE. 'R' INDICATES RELOCATED DIFFUSER AND GRILLE W/ARROW SHOWS 'N' NEW LOCATION. DASHED LINE SHOWS EXISTING DIFFSER/GRILLE LOCATION. /e DEMO DUCT WORK. City Of TukwlIa BUILDING DIVISION !SEPARATE PERMIT liEQUIRED FOR: 0 Mechanical R' r7ectrical inumbing Etas Piping i .i -y of Tukwila rt., - DIVISION PROJECT DATA STREET ADDRESS 16000 Christensenm Road Tukwila WA 98188 PROPERTY MANAGEMENT INFO Unico Properties 16040 Christensen Road, Suite 100 Tukwila WA 98188 ASSESSORS PARCEL NUMBER 2523049078 LEGAL DISCRIPTION ( See Arch Drawings Sheet 0.0.0) MECHANICAL CONTRACTOR MJR MECHANICAL, LLC PO BOX 33326 SHORELINE, WA 98133 CONTACT: MIKE RICHEY, 206-714-6374 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 17 2013 c; � ty of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 0 2013 PERMIT CENTER Project Lccanons N'?' E) CD cc M M x 0 a] 0 0 OD N CD O Cl) C') CO O CO x M CD Co O N co ('7 rn J w 2 it 7 ate) to a) J CA 0 C.) C 0 o. U 0 IV tZ a) a 0 0 a.) rn a) C/) U CD CD co CO OO CO G) 0 H- M-0 •• J •_• 4111 or r i 195 �I CFM D I ®N • 1E1071 I! AIM N 350 m 0 10 CFM N 1 1. 0 • TroInn Room a REVI WED FOR .,ODE OMPLIANCE PROVED PARTIAL MECHANICAL PLAN SCALE: 1/8" = SHEET NOTES: OReplace Existing VAV Box & Duct Heater. Reconnect controls for 2 stage operation. Q2 Remove Existing unused ductwork. SEP 17 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 0 2013 PERMIT CENTER V °° J cC) w cn s - S 03/+ co 2 illiii Li/ ,..,c): W 03 V CO M C 2 2-11 r y ao M ti t co O^O X c U O c) CL CO nU CD 0 0 a) 0 '> O O C H TM -1 • •VIII m j./ VIII■ r ,�. 4 cIa I. ■ •w_ ummu mu • r a Win • • R • • • • • 260 rFU I • • R 9 190 \j CRA 930 R— — 10'■ 10 23 CFN C DN X of 0 MIS • 410 CFM 4 • - • r n PARTIAL IV EC HAN I CAL PLAN SCALE: 1 /8" = 1'-0" 0 SHEET NOTES: r Replace Existing Duct Heater. Reconnect operation. Field Verify sizes and model numbers for RECEIVED CITY OF TUKWILA SEP 1 0 2013 PERMIT CENTER controls for 2 stage existing VAV zones.. ca N 2 cD CN N 4J V / o � N 0 0 _Y C0 0 a: TM -2 i PARTIAL MECHANICAL PLAN SCALE: 1/8" = 1'-0" SHEET NOTES: RECEIVED CITY OF TUKWILA SEP 1 0 2013 PERMIT CENTER O1 Field Verify sizes and model numbers for existing VAV zones. OStrap & properly support existing flex ductwork. V JCO —I oo M Ch r in cmJ cc 2 V Nw .0 x -) i Cr) mr 4t„, co� CUO)tD r y C') Cl) 0 X C p U 0 TD N N m ` 2 Ost o d co n U O 0 TM -3 HERMIT COORD CON. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-173 DATE: 09/10/13 PROJECT NAME: SUITES 100, 201 & 304 SITE ADDRESS: 16000 CHRISTENSEN RD X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: \ L 4-1Agi Building Division Public Works n 3 \\-/\ Fire Prevention Structural Planning Division n ❑ Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ly.")1 DUE DATE: 09/12/13 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 3 Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/10/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople P jEter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lfxl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MJR MECHANICAL LLC UBI No. 602976399 Phone 2067146374 Status Active Address Pobox 33326 License No. MJRMEML913R8 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 12/28/2009 State WA Expiration 12/28/2013 Date Zip 98133 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Ref rig (Hvac/R) Business Type Limited Liability Specialty 2 Unused Company Parent Company Business Owner Information Name Role Effective Date Expiration Date RICHEY, MICHAEL JAMES Partner/Member 12/28/2009 DAVIS, GRETCHEN SUZANNE Partner/Member 12/28/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date 1 WESTERN SURETY CO 70847425 12/16/2009 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $6,000.00 Received Date 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance 1 Company Name FARMERS INS EXCHANGE Policy Number Effective Date 604786007 12/28/2009 Expiration Date 12/28/2013 Cancel Date Impaired Date Amount Received Date $1,000,000.00 12/07/2012 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/18/2013