HomeMy WebLinkAboutPermit M13-173 - 16000 CHRISTENSEN BUILDING - SUITES 100, 201 & 304 ALTERATIONBUTTES 100, 201 & 304
16000 CHRISTENSEN RD
M13-173
City oilitukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 2523049077
Address: 16000 CHRISTENSEN RD TUKW
Project Name: SUITES 100, 201 & 304
Permit Number: M13-173
Issue Date: 09/18/2013
Permit Expires On: 03/17/2014
Owner:
Name: BRCP RIVERVIEW PLAZA LLC
Address: 248 HOMER AVE , PALO ALTO CA 94301
Contact Person:
Name: MIKE RICHEY
Address: PO BOX 33326 , SHORELINE WA 98133
Email: MIKERICHEY2@COMCAST.NET
Contractor:
Name: MJR MECHANICAL LLC
Address: PO BOX 33326 , SEATTLE WA 98133
Contractor License No: MJRMEML913R8
Phone: 206 714-6374
Phone: 206-714-6374
Expiration Date: 12/28/2013
DESCRIPTION OF WORK:
REPLACE (2) ELECTRIC DUCT HEATERS, REPLACE (1) VAV BOX, ADD 30 LF DUCTWORK, AND
RELOCATE DIFFUSERS AND GRILLES
Value of Mechanical: $5,690.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature: ..
Fees Collected:
$261.56
International Mechanical Code Edition: 2012
7
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name:
Date: 1 t l �/ (3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
n..:-�..J. nn 10 0040
PERMIT CONDITIONS
Permit No. M13-173
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
Jnr.• IMC -4/10
M13-173 Printed: 09-18-2013
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www."l_ukw.ilaaW'A.gov
Mechanical Permit No. Avy n
Project No.
Date Application Accepted:
Date Application Expires:
ollto
Atto
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 2532049078
Site Address: 16000 Christensen Road, Building 2 Suite Number: Floor: 1, 2 & 3
Tenant Name:
Yellow Pages, Suite 100, Suite 201 & Suite 304
PROPERTY OWNER
Name: Unico Properties
Address: 16040 Christensen Road, Suite 100
City: Tukwila State: WA Zip: 98188
CONTACT PERSON — person receiving all project
communication
Name: Mike Richey
Address: PO Box 33326
Address: PO Box 33326
Phone: (206) 714-6374 Fax: (206) 533-0628
City: Shoreline State: WA
Zip: 98133
Phone: (206) 714-6374 Fax: (206)
533-0628
Email: mikerichey2@comcast.net
New Tenant: ® Yes ❑..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: MJR Mechanical
Address: PO Box 33326
City: Shoreline State: WA Zip: 98133
Phone: (206) 714-6374 Fax: (206) 533-0628
Contr Reg No.: MJRMEML913R8 Exp Date: 12/28/2013
Tukwila Business License No.: BUS -0992692
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
Replace 2 electric duct heaters, replace 1 VAV box, @30 LF ductwork, relocate diffusers and grilles.
5,690
Use: Residential: New ❑ Replacement ❑
Commercial: New Replacement ❑
Fuel Type: Electric ® Gas ❑
Other:
H:\Applications\Forms-Applications On Line\2011 Applications \Mechanical Permit Application Revised it -9.1 I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE f OR HORIZED AGENT:
Signature:
Print Name:
Mike Richey
Mailing Address: PO Box 33326
H:\Applications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 0-9-I I.docx
Revised: August 2011
bh
Date: 09/10/2013
Day Telephone: (206) 714-6374
Shoreline WA 98133
City State Zip
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-43 1-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.Qov
Parcel No.: 2523049077
Address: 16000 CHRISTENSEN RD TUKW
Suite No:
Applicant: SUITES 100, 201 & 304
RECEIPT
Permit Number: M13-173
Status: PENDING
Applied Date: 09/10/2013
Issue Date:
Receipt No.: R13-02591
Initials: JEM
User ID: 1165
Payment Amount: $261.56
Payment Date: 09/10/2013 12:13 PM
Balance: $0.00
Payee: MJR MECHANICAL LLC, MICHAEL JAMES RICHE,T
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 121842
ACCOUNT ITEM LIST:
Description
261.56
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 209.25
000.345.830 52.31
Total: $261.56
.r.,,.• oe..ec..� na
Printari- n9.1n-2013
,.- INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
Mt3-,93
-6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project: t ,_- 1 tX t✓ 1 304
5Li (
TAi ype � Ie/s
1 n;
4eA
Address: 1-4
i
Ro 000 (,kt rsi-ens tisi
Date Called:
Special Instructions:
Date Wanted:
�`'�
-13
p.m' P•
'Requester:
ll'Ione No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
I
pectora -rate,: 0 _14 4 13
I I 8 REINSPECTION FEE"REQ RED. Prior to next inspection, fee must be
paid at 6300 Southcenter id.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:Typ
AL1 I+� S 10 0
17_011 ?C)1
of Ins ction:
t i ON GN -1.-Nj
Address:
la to
aped:
Wanted:_
L(! 1 -, P•Cr,.
Special Instructions:
Df;'" 2 6S �
�
� Sus ;�,,rN'
0-C.
� .
egretbeS
Date
Requesstellr:
�Phone N �'�1� -C,37�
proved per applicable codes.
Corrections required prior to approval.
COMMENTS:
n RE NSP CTION FEE REQUIRE Prior to n xt inspection. fee must be
pail at 6 00 Southcenter Blvd., uite 100. *=11 to schedule reinspection.
VAV TERMINAL BOX SCHEDULE
UNIT
NO.
VAV BOX
MODEL NO.
INLET
SIZE
COOL
CFM
MIN
CFM
HEATER
NOTES
KW
AT
CFM
VOLTS/PH
E106
VAV Reheat
10 Inch
620
10.9
45
380
Ex zone & Heater. Disable 1 stage of heat.
E107
VAV Reheat
8 Inch
700
6.2
45
435
New zone & Heater, See Note #1
E108
VAV Reheat
8 Inch
540
4.4
45
310
Ex zone & Heater
E110
VAV Reheat
12 Inch
654
6.4
45
450
Ex zone & Heater
W205
VAV Reheat
8 Inch
701
3.6
45
253
Ex zone & Heater
W206
VAV Reheat
8 Inch
800
3.5
45
253
Ex zone / New Heater, See Note#2
W207
VAV Reheat
???
NA
NA
Ex Zone Unused, No work Serves adjacent space.
W210
VAV Reheat
???
460
Verify
Ex Zone in adjacent space
305
VAV Reheat
8 Inch
3.6
45
253
Ex zone & Heater
306
VAV Reheat
8 Inch
3.5
45
253
Ex zone & Heater
???
VAV Reheat
Verify
Ex Zone in adjacent space
Note:
1, New Titus DESV Cooling Only VAV box. New Duct Heater. "Warren CBK" 6.4 KW ® 480V-3 Ph. 2 Stage 24V controls, Duct size: 12"w x 10" high.
2, Duct Heater. "Warren CBK" 5.8 KW 0 277V-3 Ph.
REVISIONS
No changes shalt be made to the scope
cf 1°ror€t without prior approval of
Tz °'ca'='i;a Building Division.
V vns will require a new plan submittal
;; ac udt; du'jitionai plan reviewfes
DR VIFIGIrstiDEX-
M-0
TM -1
TM -2
TM -3
2 Stage 24V controls, Duct size: 14"w x 10" high.
COVER SHEET, SCHEDULES, LEGEND, NOTES
Yellow Pages TI HVAC Plan
Suite 201 Market Ready (No Tenant)
Suite 304 Market Ready (No Tenant)
FILE COP■
Permit No.
plef review approval is subject
to errors and omissions.
1, of construction documents does not author:. 3
adopted•
codeor ordinance. Recti:tit
04:04: ckri�
Field + +I and
., is ed9 d
I Wadi
1111111111
E
CONSTRUCTION NOTE,
TO EXISTING THERMOSTAT LOCATION.
RO
T
RELOCATED THERMOSTAT LOCATION.
'D' INDICATES DEMO EXISTING DIFFUSER/GRILLES.
'E' INDICATES EXISTING S/A DIFFUSER & R/A GRILLE.
'R' INDICATES RELOCATED DIFFUSER AND GRILLE W/ARROW SHOWS
'N' NEW LOCATION. DASHED LINE SHOWS EXISTING DIFFSER/GRILLE
LOCATION.
/e DEMO DUCT WORK.
City Of TukwlIa
BUILDING DIVISION
!SEPARATE PERMIT
liEQUIRED FOR:
0 Mechanical
R' r7ectrical
inumbing
Etas Piping
i .i -y of Tukwila
rt., - DIVISION
PROJECT DATA
STREET ADDRESS
16000 Christensenm Road
Tukwila WA 98188
PROPERTY MANAGEMENT INFO
Unico Properties
16040 Christensen Road, Suite 100
Tukwila WA 98188
ASSESSORS PARCEL NUMBER
2523049078
LEGAL DISCRIPTION
( See Arch Drawings Sheet 0.0.0)
MECHANICAL CONTRACTOR
MJR MECHANICAL, LLC
PO BOX 33326
SHORELINE, WA 98133
CONTACT: MIKE RICHEY, 206-714-6374
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 17 2013
c; �
ty of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 1 0 2013
PERMIT CENTER
Project Lccanons
N'?'
E)
CD
cc
M
M
x
0
a]
0
0
OD
N
CD
O
Cl)
C')
CO
O
CO
x
M
CD
Co
O
N
co
('7
rn
J
w
2
it
7
ate)
to
a)
J
CA
0
C.)
C
0
o. U
0
IV
tZ
a)
a
0
0
a.)
rn
a)
C/)
U
CD
CD
co
CO
OO
CO
G)
0
H-
M-0
••
J
•_•
4111
or
r
i
195 �I
CFM
D
I
®N
•
1E1071
I!
AIM
N 350
m
0
10 CFM
N
1
1. 0
•
TroInn Room
a
REVI WED FOR
.,ODE OMPLIANCE
PROVED
PARTIAL MECHANICAL PLAN
SCALE: 1/8" =
SHEET NOTES:
OReplace Existing VAV Box & Duct Heater. Reconnect controls for
2 stage operation.
Q2 Remove Existing unused ductwork.
SEP 17 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 1 0 2013
PERMIT CENTER
V
°°
J
cC)
w cn s -
S
03/+ co 2
illiii Li/ ,..,c): W
03
V CO M C
2 2-11
r y
ao
M ti t
co O^O
X c U
O c)
CL CO nU
CD
0
0
a) 0
'> O
O C
H
TM -1
• •VIII m j./
VIII■ r ,�. 4
cIa I.
■
•w_
ummu mu
• r a
Win
•
•
R
•
•
•
•
•
260
rFU
I
•
•
R
9
190
\j
CRA
930
R— —
10'■
10
23
CFN
C
DN
X
of
0
MIS
•
410
CFM
4
•
-
•
r
n
PARTIAL IV EC HAN I CAL PLAN
SCALE: 1 /8" = 1'-0"
0
SHEET NOTES:
r
Replace Existing Duct Heater. Reconnect
operation.
Field Verify sizes and model numbers for
RECEIVED
CITY OF TUKWILA
SEP 1 0 2013
PERMIT CENTER
controls for 2 stage
existing VAV zones..
ca
N 2
cD
CN
N
4J
V /
o
� N
0
0
_Y
C0
0
a:
TM -2
i
PARTIAL MECHANICAL PLAN
SCALE: 1/8" = 1'-0"
SHEET NOTES:
RECEIVED
CITY OF TUKWILA
SEP 1 0 2013
PERMIT CENTER
O1 Field Verify sizes and model numbers for existing VAV zones.
OStrap & properly support existing flex ductwork.
V
JCO
—I oo
M Ch
r
in cmJ
cc 2
V Nw
.0
x -)
i Cr) mr 4t„,
co� CUO)tD
r y
C') Cl) 0
X C p U
0 TD N N
m `
2 Ost o
d co n U
O 0
TM -3
HERMIT COORD CON.
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-173 DATE: 09/10/13
PROJECT NAME: SUITES 100, 201 & 304
SITE ADDRESS: 16000 CHRISTENSEN RD
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
\ L
4-1Agi
Building Division
Public Works
n
3 \\-/\
Fire Prevention
Structural
Planning Division
n
❑ Permit Coordinator U
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ly.")1
DUE DATE: 09/12/13
Incomplete ❑ Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route 3 Structural Review Required No further Review Required n
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 10/10/13
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople P jEter Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with Lfxl to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MJR MECHANICAL LLC UBI No. 602976399
Phone 2067146374 Status Active
Address Pobox 33326 License No. MJRMEML913R8
Suite/Apt. License Type Construction Contractor
City Seattle Effective Date 12/28/2009
State WA Expiration 12/28/2013
Date
Zip 98133 Suspend Date
County King Specialty 1 Heating/Vent/Air-Conditioning And Ref rig
(Hvac/R)
Business Type Limited Liability Specialty 2 Unused
Company
Parent
Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
RICHEY, MICHAEL JAMES
Partner/Member
12/28/2009
DAVIS, GRETCHEN SUZANNE
Partner/Member
12/28/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
1
WESTERN SURETY CO
70847425
12/16/2009
Expiration Date
Until Cancelled
Cancel Date
Impaired Date
Bond Amount
$6,000.00
Received Date
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
1
Company Name
FARMERS INS
EXCHANGE
Policy Number
Effective Date
604786007
12/28/2009
Expiration Date
12/28/2013
Cancel Date
Impaired Date
Amount
Received Date
$1,000,000.00
12/07/2012
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx 09/18/2013