HomeMy WebLinkAboutPermit M13-175 - KING COUNTY LIBRARY SYSTEM - ALTERATIONKING COUNTY LIBRARY SYSTEM 1386 SOUTHCENTER MALL M13-175 City ofltukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL, PERMIT Parcel No.: 9202470010 Address: 1386 SOUTHCENTER MALL TUKW Project Name: KING COUNTY LIBRARY SYSTEM Permit Number: M13-175 Issue Date: 09/25/2013 Permit Expires On: 03/24/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: JESSE MONTEZ Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: JESSE.MONTEZ@MACMILLER.COM Contractor: Name: MACDONALD MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE WA 98106 Contractor License No: MACDOMF972BF Phone: 206 768-4178 Phone: 206 763-9400 Expiration Date: 01/06/2015 DESCRIPTION OF WORK: INSTALL (1) 2.5 TON DUCTLESS SPLIT SYSTEM. INSTALL ROOFCURB AS REQUIRED AND REFRIGERANT LINES BETWEEN INDOOR AND OUTDOOR UNIT. Value of Mechanical: $6,750.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $274.13 International Mechanical Code Edition: 2012 Date: ii -)z-- ,- (r)) I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: g7.3 /f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 11 Q e -it: Drinforl• f1Q2,429f l4 PERMIT CONDITIONS Permit No. M13-175 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-175 Printed: 09-25-2013 111 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht tp://www.Tuk wi la W A . gov Mechanical Permit No. Project No. Date Application Accepted: tl 1. I t \'? Date Application Expires: 029\ t t I L{ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 9202470010 Site Address: 1386 Southcenter Mall Tukwila, WA 98188 Suite Number: Backrm Floor: 1 & Roof Tenant Name: Westfield S/C Mall - King County Library System New Tenant: ❑ Yes m ..No PROPERTY OWNER Name: JESSE MONTEZ Name: WESTFIELD CORP. City: SEATTLE State: WA Zip: 98106 Address: 2800 Southcenter Mall Email: jesse.montez@macmiller.com City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: JESSE MONTEZ Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4178 Fax: (206) 768-4179 Email: jesse.montez@macmiller.com MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 12/31/2013 Tukwila Business License No.: BUS -0100868 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: INSTALL (1) 2.5 TON DUCTLESS SPLIT SYSTEM, INSTALL ROOFCURB AS REQUIRED AND REFRIGERANT LINES BETWEEN INDOOR AND OUTDOOR UNIT. 6,750 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric m Gas ❑ Other: H:\Applications\Forms-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI 1 AGENT: Signature: Print Name: DARLA DOLL Mailing Address: 7717 DETROIT AVE SW H:\Applications\Forms-Applications On Line\2011 Apphcat onsUlechamcal Permit Application Revised 8-9-I (.dors Revised: August 2011 bh Date: 09/10/2013 Day Telephone: (206) 768-4278 SEATTLE WA 98106 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Eov RECEIPT Parcel No.: 9202470010 Permit Number: M13-175 Address: 1386 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/11/2013 Applicant: KING COUNTY LIBRARY SYSTEM Issue Date: Receipt No.: R13-02597 Initials: User ID: JEM 1165 Payment Amount: $274.13 Payment Date: 09/11/2013 12:22 PM Balance: $0.00 Payee: MACDONALD-MILLER FACILITY SOLUTIONS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3722 274.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 219.30 000.345.830 54.83 Total: $274.13 rinr• Rnrcint_f1C. Printed• 09-11-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION C :. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 • (206) 431-3670 Peripit Inspection: Request Line (206) 431-2451 A41.3-1`7_5 Pr jest:. K, n & coLJ r L 5rn-r Ty of I spection: r Kir, 6,6_r,�-tom &) Address: / 3 m41 f D Called: , g� v6 2......A/ 4. �, �v�-L.._. Special Instructions: Date Wanted: co '.2i a p.m. Requester: Phone No•. -3'1'(1 Approved per applicable codes. C7Corrections required prior to approval. COMMENTS: Inspec r: Date t: n REINSPECTION FEE R'QU R Pri to next inspection; fee must be paid at 6300 Southcenter Blv .. Suite 00. Call to schedule reinspection. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-175 DATE: 09/11/13 PROJECT NAME: KING COUNTY LI BRARY SYSTEM SITE ADDRESS: 1386 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after Permit Issued DEPARTMENTS: R-�3 Building Division Public Works roAn N' 0 of 't3 . Fire Prevention 1111 Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [,K1 DUE DATE: 09/12/13 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route i Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/10/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 0 Contractors or Tradespeople ,Er Friendly Page i Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company MACDONALD MILLER FAC SOL INC 2067639400 Po Box 47983 Seattle WA 98106 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602254260 Active MACDOMF972BF Electrical Contractor 1/6/2003 1/6/2015 General Unused Other Associated Licenses LicenseSpecialty Name Type Specialty 1 2 Effective Date Expiration Date Status ENCOMMS981JP ENCOMPASS MECHANICAL SERVICES Electrical Contractor Hvac/Rfrg Unused 4/17/2002 4/17/2004 Archived ENCOMMS984JP ENCOMPASS MECHANICAL SERVICES Electrical Contractor Maintenance Hvac/Rfrg 4/17/2002 4/17/2004 Archived MACDOMS982BM MACDONALDMILLER SERVICERVICEINC Electrical Contractor Maintenance Unused 1/14/2002 1/14/2004 Archived MACDOMS011R5 MACDONALD MILLER SERVICE INC Electrical Contractor Hvac/Rfrg Unused 12/10/1999 12/10/2003 Archived MACDOMC329B5 MACDONALD MILLER CO INC Electrical Contractor General Unused 1/25/1968 1/31/2003 Archived Electrical Administrator INFORMATION License ADAMSEJ916B2 Name ADAMS, EDWARD J Status Active Business Owner Information Name Role Effective Date Expiration Date CT CORP SYSTEM Agent 02/11/2013 SIMONDS, DERRICK President 02/11/2013 NICHOLES, STEVE Secretary 02/11/2013 TURLEY, DOUGLAS Treasurer 02/11/2013 WEBSTER, MARK Vice President 02/11/2013 HACK, RICHARD R Agent 01 /06/2003 02/11/2013 SIGMUND, FRED J President 01/06/2003 02/11/2013 KOPET, TYLER C Secretary 01/06/2003 02/11/2013 KOPET, TYLER C Treasurer 01/06/2003 02/11/2013 LOVELY, STEVE C Vice President 01/06/2003 02/11/2013 Bond Information Page 1 of 2 Bond 1 Bond Company Name LIBERTY MUTUAL INS CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 023006952 12/11/2002 Until. Cancelled $4,000.00 01/08/2003 httos://fortress.wa.i?ov/lni/bbip/Print.aspx 09/25/2013 RP\00\2 — Engineering\DWG\Shts\7336739TM0_01.dwg a rn 1.1 N 0 E O a 0 N 0 0 HVAC "ABBREVIATION. ABBV A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS FULL NAME COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ABBV ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM FULL NAME EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL ABBV FULL NAME OSA OUTSIDE AIR OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS Tv TWG TWR TYP UNO VD VFD 0 OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER EQUIP. UNIT # I RATED SOUND POWER (Dba) ACOUSTICAL # OF ADD'N PER ARI REFLECTIVE 275-97 SURFACES EQUIP. LOCATION FACTOR BARRIER SHIELDING FACTOR SOUND PATH FACTOR DISTANCE TO CLOSEST ADJACENT PROPERTY (FT.) DISTANCE REDUCTION FACTOR SOUND LEVEL @ ADJ. PROP. (dBA) ZONING OF SENDING PROP. ZONING OF REC'G PROP. HOURS OF EQUIP. OPERATION MAX. ALLOWABLE SOUND LEVEL (dBA)* CU -1 i 56 0 0 0 0 453 50 7 COMM. COMM 9:00 a.m. - 9:00 p.m. 60 * PER MUNICIPAL NOISE ORDINANCE & ARI -275 UNIT NO. DAC-1/CU-1 MANUFACTURER INDOOR UNIT OUTDOOR UNIT MODEL FUJITSU ASU3OCLX1 NOM. TONS 2.5 CFM SEER ELECTRICAL VOLT/PH MCA WT LBS MODEL CFM ELECTRICAL WT VOLT/PH MCA LBS NOTES 1000 16.50 208/230/1 31 I AOU3OCLX1 1000 208/1 22.0 150 NEW,1-8 NOTES: 1. PROVIDE POWER WIRING AND DISCONNECT AS REQUIRED. 2. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 3. WITH FACTORY CONDENSATE PUMP. PROVIDE 3/4" TYPE L COPPER CONDENSATE DRAIN TO BUILDING JANITOR SINK. 4. INDOOR UNITS FACTORY WIRED AND CIRCUIT PROTECTED FOR SINGLE POINT ELECTRICAL CONNECTION. 5. CONFIRM EQUIPMENT VOLTAGES ON SITE, CONFIRM SINGLE PHASE PRIOR TO EQUIPMENT ORDER. 6. WITH WIRELESS REMOTE DIGITAL THERMOSTAT. 7. WITH R410A REFRIGERANT. 8. WITH BUILT-IN LOW AMBIENT. CTLEGEc DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 1 4x1 2 ROUND SHEETMETAL WRAPPED W/ INSULATION (2") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x 12C SHEETMETAL WRAPPED W/ INSULATION (2") 1 4x1 2W BARE FLAT OVAL SHEETMETAL 1 4x 120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 14x120W EXPOSED QUALITY SHEETMETAL 1 4x1 2Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 1 4x1 2 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR VICINITY MAP NO SCALE SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical Plumbing Gas Piping City of Tukwila Bill D F G DIVISION AC: GENERAL:.NOTE 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-6 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-6 MIN.). DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R6 MIN.). AIR DUCT (R6 MIN) SUPPLY DUCT WHICH CONVEY SUPPLY AIR AT TEMPERATURES LESS THAN 55 DEG F OR GREATER THAN 105 DEG F SHALL BE INSULATED WITH A MINIMUM OF R-3.3, WHEN LOCATED IN CONDITIONED SPACE. 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BEESLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 1' 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2012 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC), COMMERCIAL PROVISIONS, SECTION C408 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ("MONOCOAT") IS NOT ACCEPTABLE (BY GC). ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. USE SECTION 909.5 OF THE 2012 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTIONi' ROOM/SHAFT PRESSURE. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013 City of u vila BUILDING ISION 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500D): MOTORIZED DAMPERS: 4 CF GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC, COMMERCIAL PROVISIONS, SECTION C402.4.5.2 AND C403.2.4.4. EXCEPT AS ALLOWED BY WSEC. 21. RETURN AIR SHAFTS TO BE CONSTRUCTED BY THE G.C. TO WITHSTAND A MINIMUM 20 PSF DIFFERENTIAL PRESSURE ACROSS THE WALL. DIFFERENTIAL PRESSURE IS BASED UPON THE MAXIMUM STATIC PRESSURE CAPABILITY OF FAN SYSTEMS SUBJECT TO AUTOMATIC DAMPER CLOSURE. . PRESSURIZATION SHAFTS SHALL BE CONSTRUCTED BY THE G.C. AS FOLLOWS: - SHAFTS SERVED BY PRESSURIZATION FANS RATED UP TO 1" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 10 PSF DIFFERENTIAL PRESSURE. - SHAFTS SERVED BY PRESSURIZATION FANS RATED BETWEEN 1-2.5" STATIC PRESSURE TO BE CONSTRUCTED TO WITHSTAND 20 PSF DIFFERENTIAL PRESSURE. - FOR SHAFTS SERVED BY PRESSURIZATION FANS RATED ABOVE 2.5" STATIC PRESSURE, CONTACT MECHANICAL ENGINEER. TITLE PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL FOREMAN AIR BALANCE FOREMAN REFRIGERATION FOREMAN LOW VOLT ELECTRICAL FOREMAN LINE VOLT ELECTRICAL FOREMAN PLUMBING SUPERINTENDENT PLUMBING FOREMAN COMMISSIONING FOREMAN DDC CONTROLS COORDINATOR FACILITIES DIRECTOR FACILITIES DIRECTOR NAME JESSE MONTEZ ROB PAINTER TIM FELTON STEVE BAKER DEAN GRASSER DAVE GOFF ED ADAMS KELLY KING PAUL MONSEN BRIAN WHEELER BRIAN WHEELER ARON MOON JIM WORSDALE COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206-768-4178 206-768-4122 206-407-2692 206-768-3824 206-768-4270 206-407-2638 206-396-9321 206-768-3962 206-255-6444 206-571-2659 206-571-2659 206-255-4409 206-255-4421 EMAIL JESSE.MONTEZ@MACMILLER.COM ROB.PAINTER@MACMILLER.COM TIM. FELTON@MACMI LLER.COM STEVE.BAKER@MACMILLER.COM DEAN.GRASS ER@MACM ILLER.COM DAVE.GOFF@MACMILLER.COM EDADAMS@MACMILLER.COM KELLY.KING@MACMILLER.COM PAUL.MONSEN@MACM I LLER.COM BRIAN.WHEELER@MACMILLER.COM BRIAN.WHEELER@MACMILLER.COM PROVIDE AND INSTALL STAND ALONE 2.5 TON DUCTLESS SPLIT SYSTEM. ROUTE CONDENSATE TO NEAREST JANITOR SINK. PROVIDE NEW ELECTRICAL RUN FROM EXISTING DISTRIBUTION PANEL TO CONDENSING UNIT. PROVIDE LOW VOLTAGE AND LINE VOLTAGE POWER FROM CONDENSING UNIT TO INDOOR UNIT AS REQUIRED. PROVIDE AND INSTALL ROOF CURB AS REQUIRED. PROVIDE AND INSTALL REFRIGERANT LINES BETWEEN INDOOR AND OUTDOOR UNIT AS REQUIRED. NOTE: EXISTING COOLING VAV TO REMAIN. NAME TITLE NAME TITLE TM0.01 TM0.01S TM2.01 TM2.03 SCHEDULES - HVAC SITE PLAN FIRST FLOOR - HVAC ROOF PLAN - HVAC APN# 920247-0010 ADDRESS: KING COUNTY LIBRARY SYSTEM - SOUTHCENTER 1386 SOUTHCENTER MALL #1115 TUKWILA, WA. 98188 LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) REVISIONS No chances shall be made to the scope q of work without prior approval of I Tukwila Building Division. INOTE.: Revisions will require a new plan submittal I uld may include additional plan review fees. E FILE COPY Permit No. J` ' «� Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt rf approved Field Copy and #;; III is acknowledged: By ^{` 0 Date: 5/.2 t 3 City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 1 2013 PERMIT CENTER 1 /8" = 1'-0" 0 0 cu E 0 0 aL .E0 C'41 E WA Lic No: MACDOFS980RU I I I I I I I I I I I I I I I I REVISIONS: 1 11 '2I 0 0 O O N rz W a. I I I 1< F- J 0 (!) (!) C!) W J F- U 0 0 o2 Q W U(1) I W � zm LI -I-1 ZHQ HZ 2 D D FW- T O O i �U=. U) 0 ~ _!. OJ 0Z; REVISIONS: z 0 F- (/) - ( ) z 0 U 0 0 W Co (J) F- 0 z ENGINEER: LAST REVISED: J MONTEZ 09-04-13 CHECKED BY: B GEZON CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: D-3458-7336739-00 SHEET NUMBER: DATE PLOTTED: TM0.01 STRANDER BLVD BAKER BLVD REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013 City of Tukwila BUILDING DIVISION • .. . RECEIVED CITY OF TUKWILA SEP 1.t 2013 PERMIT CENTER .macmiller.com WA Lic No: MACDOFS980RU PERMIT SET F- 0 Ui 0 0 0 Etw C41/2 <u co) >- oCct zoo w-1 0>- IF - 1—z D D 00 CO 0 U) 0 0 Z ENGINEER: —J 2 I I 0 (/) co co co co <t - J M 0 NTEZ CHECKED BY: B GEZON ED 1/8" = 1'-0" CAD: D LAMBERT CD I•••• LU cc LU UJ 0 REVISIONS: REVISIONS: z 0 F - z0 0 0 LU D 0 z LAST REVISED: 09-04-13 DATE PLOTTED: ISSUE DATE: DRAWING NUMBER: D-3458-7336739-00 SHEET NUMBER: TM0.01 S Engineering\DWG\Shts\7336739TM2_01.dwg 0 0 Back Room Ductless Split 0_ 0 71: 0 0 0 E 0 0 co0 0 DIGITAL WIRELESS REMOTE THERMOSTAT REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013 City of Tukwila BUILDING DIVISION ROUTE 3/4" CONDENSATE LINE TO I SINK TAIL PIECE OR APPROVED DRAIN 0 ric , i DAC -1 • . : . . . . . . . . . ;.. „ . ....LIQUID AND -(JCTION LINES SHOWN .. . . ----.-------ASL-S[iNGLE-LINE---FOR CLARITY - I N: , FIELD ROUE REFRIGERANT LINES TO CONDENSING UNIT ON ROOF. 11113%. 17 LA\ AREA OF WORK 0 CO 0 N- .:- N- CO Cr? N- (7) a5* o 0 as o , > < co (c't -45 (NI 0 • • a) 0 r•-• 0_ E E E co oo u_ 0 0 z 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NDI 0 0 0, 1— LLI co co co 61TyROECFETIuVKEwD ILA PERMIT CENTER__ CHECKED BY: ENGINEER: J MONTEZ B GEZON SEP 1 1 2013 ct 1/8" = 1'_O" U) uJ uJ IJJ 0 REVISIONS: Lu 0 REVISIONS: z 0 F- 0 0 0 w (1) 0 z LAST REVISED: 09-04-13 DATE PLOTTED: CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: D-3458-7336739-00 SHEET NUMBER: TM2.01 Engineering\DWG\Shts\7336739TM2_03.dwg Back Room Ductless Split — RP\00\2 J:\733\6739 KCLS Southcenter ADJACENT TENANT . a til i [ I.) [ o csi I HALL WAY CU -1 REFRIGERANT LINES DOWN TO DAC -1 SHOWN AS SINGLE LINE FOR CLARITY. EAST MALL ENTRANCE SHEET NOTES: 0 SLEEPERS PROVIDED AND INSTALLED BY M.C. 0 ROOF PATCH AND REPAIR BY M.C. r,*.m REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013 City of Tukwila BUILDING DIVISION 22 GAUGE GALV SLEEPER CAP BY M.C. LAG BOLT/ ANCHOR BOLT BY G.C. ROOFING MOPPED UP (4) SIDES OF SLEEPER BY G.C. 4x4 PRESSURE TREATED WOOD SLEEPER, BY G.C. LOCATION LAYOUT BY M.C. CANT STRIP AND ROOFING BY G.C. ROOF N./ ROOFTOP EQUIPMENT SLEEPER SUPPORT DETAIL N.T.S. /<EvL_A\ • RECEIVED CITY OF TUKWILA SEP 1 1 2013 PERMIT CENTER AREA OF WORK /8" = 1'-0" E r,f. • E E WA Lic No: MACDOFS980RU I I I I I I I I 11111111 Ins_ I 0 cis> 0 PERMIT SET 0 (i) 0 0 0 w O) < w I -m w -J • >- I 1- Z D D O 0 U) 0 o zU) 0 _J ENGINEER: 2 rY w co z oo WO) 0< F0 - CO CO Cr) J MONTEZ CHECKED BY: B GEZON CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: D-3458-7336739-00 Lii a 1)))))))))4)adaalla REVISIONS: 1 REVISIONS: CO UI ci UI z 0 F- 0 F- (/) z0 0 0 LI] (/) F0 z LAST REVISED: 09-04-13 DATE PLOTTED: SHEET NUMBER: TM2.03