Permit M13-181 - DIGITAL FORTRESS - ALTERATION
DIGITAL FORTRESS 12201 TUKWILA INTERNATIONAL BL M13-181 City ol/I'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0923049120 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Project Name: DIGITAL FORTRESS Permit Number: M13-181 Issue Date: 10/09/2013 Permit Expires On: 04/07/2014 Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: KAYLENE LARSON Address: 1221 2 AV N , KENT WA 98032 Email: KLARSON@HERMANSON.COM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AVN , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 206 963-5097 Phone: 206-575-9700 Expiration Date: 08/25/2014 DESCRIPTION OF WORK: PROVIDE AND INSTALL SPLIT A/C UNIT, DISTRIBUTION DUCT WORK AND CONNECTING PIPING. INCLUDES OUTSIDE AIR DAMPER. Value of Mechanical: $4,800.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $249.00 International Mechanical Code Edition: 2012 Date: Ito[oe'AV1) I hereby certify that I have read and exminel1 this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th, w ether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: 4 / / ((//X ((J v \r Date: (Q M kS Print Name: L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. uIIn .r4n RA11_1Al Printari• 1 n_nQ_9fl14 PERMIT CONDITIONS Permit No. M13-181 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-181 Printed: 10-09-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. y%13-leI Project No. Date Application Accepted: Date Application Expires: 0g/d©4 3 0 3/9vy (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 12201 Tukwila International Blvd. Tenant Name: Digital Fortress PROPERTY OWNER Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKWILA INTERNATIONAL BLV City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Kaylene Larson Address: 1221 2nd Ave n City: Kent State: WA Zip: 98032 Phone: (206) 963-5097 Fax: (253) 796-5992 Email: klarson@hermanson.com King Co Assessor's Tax No.: 092304-9120 Suite Number: None Floor: First New Tenant: ❑ Yes 0..No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: (206) 575-9800 Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2014 Tukwila Business License No.: 09-459 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Provide and install split A/C unit, distribution duct work and connecting piping. Includes outside air damper. 4,800 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement 0 Fuel Type: Electric m Gas ❑ Other: H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised K-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system I Air handling unit <10,000 cfrn Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Flood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW EL' "OR � I1j0ZED A�ENT Signature: 1 / , /j/L (i//h�U,S Date: 1 I zo l 3 Print Name: Kaylen(r'L.arson Day Telephone: (206) 963-5097 Mailing Address: 1221 2nd Ave N Kent WA 98032 H:Wpplications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0923049120 Permit Number: M13-181 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 09/20/2013 Applicant: DIGITAL FORTRESS Issue Date: Receipt No.: R13-02687 Initials: User ID: LAW 1632 Payment Amount: $249.00 Payment Date: 09/20/2013 10:54 AM Balance: $0.00 Payee: HERMANSON COMPANY LLP TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 479876 ACCOUNT ITEM LIST: Description 249.00 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 199.20 000.345.830 49.80 Total: $249.00 Printprl n9_7n_9n13 • INSPECTION RECORD Retain a copywith permit !VII I INSPECT/ON NO. PERMIT NO. `' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro'ect: _ i G ri A L 1--o{27-Ft C Type of Inspection: C t tV A (_"_ Address: I -Z-2-0 t TT Date Called: Special Instructions: . Date Wanted: ICS— I u - a.m p.m. Requester: Phone No: 02_OCn-(,►3'C�1-Z Approved per applicable codes. Corrections required prior to approval. COMMENTS: tor: Date: REINSPECTION FEE EQUIRED.Prior to next inspection, fee must be paid at 6300 Southce ter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD(': Retain a copy with permit /79/ 3—tc9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA'98188 (206) 431-3670 Permit Inspection Request Line (206) 431-251 Project: 1)/6/7 4G :f -d i 7 SS Type of leiT /- 1 '',-4-/' ction: �- A; / -7 Address: / 2oL O ! 7-:_r- z Date Called: Special Instructions: Special Date Wanted: Requester: Phone No: c9..0 6 - 7 9— tiZ pproved per applicable codes. COMMENTS: Corrections required prior to approval. C)-) Re q6 -,AJ _ 41((A/,i i Date: 4-7 + et") Cry? REIN ' ECTION FEE REQUIRED Prior to nexq'inspection, fee must be pa' . at 6300 Southcenter Blvd., uite 100. Calt11111 to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit d 1 h3/ 3 -/ 8 / PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter.Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,• D( (7 ?IL, ro✓fs"' Type.-oqf Inspection: i• OrGN -.1-f Address: Date Called: Special Instructions: Q((Ci/eSSG /Zzo/ 1 �- Date Wanted: /0 —/,5 — 3 Ca.rn) p.m. Requester: Phone No: 02,66 -z2_5 -'s / UApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 014- - i v .__Z-ic 5z1L44 i� 67 t7 5 f /'9r & I Rate: J C� 15 l� PECTION FEE REQUIRED. rior to next inspection. fee must be at 6300 Southcenter Blvd.. S ite 100. Call tol schedule reinspection. � PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER:. N_ 11.3-181 PROJECT NAME: DIGITAL FORTRESS DATE: 09/20/13 SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 10.°I.l' Building Division .® Public Works V\- 0'1, 21-1,13 ire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete CI DUE DATE: 09/24/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 10/22/13 Not Approved (attach comments) U DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople P ter Friendly Page General/Specialty Contractor A business registered as a construction contractor with LBJ to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite/Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2014 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner/Member 08/05/2010 Amount BROCK, DANIEL L Partner/Member 08/05/2010 GL0370326110 FOX, DEAN M Partner/Member 08/05/2010 HENGEL, STEPHEN A Partner/Member 08/05/2010 American Zurich Insurance Comp DYCKMAN, KENNETH A Partner/Member 08/05/2010 ROBINETT, PAUL J Partner/Member 08/05/2010 10 HERMANSON, RICHARD L Partner/Member 01/01/1980 08/21/2012 ALMON, KEVIN Partner/Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner/Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 Zurich American Ins Co GL0370326110 08/21/2013 08/21/2014 $1,000,000.0008/16/2013 11 American Zurich Insurance Comp GL0370326109 08/21/2012 08/21/2013 $1,000,000.00 08/14/2012 10 American Zurich Insurance Comp GL0370326108 08/21/2011 08/21/2012 $1,000,000.0008/18/2011 9 American Zurich Ins Co GL0370326107 08/21/2010 08/21/2011 $1,000,000.00 08/18/2010 8 GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08/24/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 10/09/2013 S 100 (!) A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTU H CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP EWT EXIST EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ IBC ICW ID MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL CEILING TILE ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/DEGREES DIAMETER DAMPER DOWN DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ INTERNATIONAL BUILDING CODE INDUSTRIAL COLD WATER INSIDE DIAMETER/DIMENSION E EER MC N N WG PLV KW LAT LB/LBS LF/LIN FT LPG LPS LVG LWA LWG LWT MAX MAU MBH MCA MD MFR MISC MIN MPS MT MTD MUW NA NC NG/NGAS NIC NO NPW N -R OA/OSA OBD OD PCF PD PH POC P/PRESS PSI PSIG QTY R RA RD/RND REF REQ RESID RF RG RL RPM RS S SA SAT SD S/D S_C SEER SENS SL SM SPEC SO SOG SP SF SS STRUC TA TEMP TBD TOD TOS TOT TSP TSTAT TYP UH UNO V VD VEL VERT VFD VOL W WB WG W W/O W/SF WSEC NVERT ELEVATION NTEGRATED ENERGY EFFICIENCY RATIO NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND/POUNDS LINEAL FOOT/FEET LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MOUNTED MAKE-UP WATER NOT APPLICABLE NORMALLY CLOSED/NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REQUIRED RESIDENTIAL RELIEF REFRIGERANT DISCHARGE GAS REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION/SUPPLY AIR TEMPERATURE SMOKE DETECTOR SLIP & DRIVE CONNECTION SEATTLE _ CODE SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SOUND LINED SHEETMETAL SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET STAINLESS STEEL STRUCTURAL TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: l evlsicns will require a new plan submittal anJ rany include additional plan review fees. MECHANICAL LEGEND 1oxio E4 ioxio 10X10 =1OX10 :10X10 1F 10X10 a10X10❑i 6 100 ion � 100 0 bl2Xl000r 12X100; RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY 100 5.2 I- DUCT OVERLAP 100 1, 1001 R/D I t D (S) IBDDI BOOT TAP 45° TAP VOLUME DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) L Iva _16X16SL MEM& z cDA ##X## lo CD1-100 80 T T'STAT/TEMP SENSOR H HUMIDITY SENSOR 101 SMOKE DETECTOR sP STATIC PRESSURE SENSOR COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT (SL) FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE @CARBON DIOXIDE SENSOR 0 CARBON MONOXIDE SENSOR EXISTING DUCTWORK MOla DEMO DUCTWORK WALL -MOUNTED GRILLE z o PIPE ELBOW UP PIPE ELBOW DN z z DIRECTION OF FLOW z z DIRECTION OF SLOPE DOWN z 7 PLUG OR CAP z ® z PRESS REDUCING ASSEMBLY z ��a z SOLENOID VALVE z ® z PUMP z-CHWS /CHWR-s CHILLED WATER SUPPLY/RETURN RL/RS-s REFRIGERANT LIQUID/SUCTION NG -s NATURAL GAS z- LPG s LIQUID PROPANE GAS 2-CDWS /CDWR-s CONDENSER WATER SUPPLY/RETURN z---HWS/HWR-5 HEATING WATER SUPPLY/RETURN COND -5 CONDENSATE z- FOV -s FUEL OIL VENT 2-FOS/FOR-5 FUEL OIL SUPPLY/RETURN RDG -i REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2012 S 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 2012 & 2012 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN C403.2.4) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5°F (10°F FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE SEATTLE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE SEATTLE ENERGY CODE C4080. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD /-2-- WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION RESID INSULATION R -VALUE REMARKS M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC R-7 M2.01 PARTIAL 1ST FLOOR PLAN & EQUIPMENT SCHEDULES - HVAC OUTSIDE AIR WITHIN CONDITIONED SPACE VARIES R-8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY AIR <55' OR >105' WITHI ON ONED SPACE R-3.3 APN NUMBER 0923049120 LEGAL DESCRIPTION BEGIN NW CORNER OF NE 1/4 OF SE 1/4 TH S 89-16-35 E 100 FT TH S 24-13-53 E 969.61 FT TO POINT OF BEGINNING TH N 65-46-07 E 58.17 FT TH N 63-32-48 E 62.13 FT TH S 22-47-01 E 21.44 FT TH N 65-30-25 E 199.33 FT TO POINT ON WLY R/W LINE OF PRIMARY STATE HIGHWAY NO 1 (SR 99) SOUTH 118TH ST TO JCT SSH NO 1-K APPROVED JULY 23, 1957 TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2805 FOOT RADIUS NON TANGENT CURVE TO RIGHT, CENTER BEARING S 65-44-51 W, THRU C/A OF 1-16-30 DISTANCE OF 62.42 FT TH FOLLOWING SAID WLY R/W LINE N 67-01-21 E 10 FT TH FOLLOWING SAID WLY R/W LINE ALONG ARC OF 2815 FOOET RADIUS NON TANGENT CURVE TO RIGHT CENTER BEARING S 67-01-21 W THRU C/A OF 6-31-21 DISTANCE OF 320.45 FT TH S 73-32-42 W 16.58 FT TH S 71-35-51 W 61.96 FT TH N 78-38-58 W 7.83 FT TH S 75-53-44 W 106.07 FT TH N 05-01-10 W 18.41 FT TH S 82-22-27 W 64.93 FT TH S 63-55-24 W 58.16 FT TH N 24-13-53 W 334.22 FT TO POINT OF BEGINNING - LOT B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L98-0033 RECORDING NO 9810059013 REVIEWED FOR CODE COMPLIAN1 APPROVED OCT 00 4 2013 nW3 City of T ila BUILDING ISION 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE - USE PENETRATIONS ECTI NT909.50OFTTHES2012 CONSTRUCTION ALLOWABLE ,LECAOKAGETAREA,NFOLLOWINGA THEE BE SEALED ON BOTH STAIR SHAFT CONSTRUCTION. -ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER R403. 26. ELECTRICAL SUBMETERING OF SYSTEMS AS REQUIRED BY NERGY CODE CHAPTER 12 IS BY ELECTRICAL THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURN N HE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION. A PERMANENT AND VISIBLE DISPLAY IS TO BE PROVIDED FOR EACH BUILDING, READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL 27. THE PROJECT TEAM IS COLLECTIVELY RESPONSIBLE FOR COMPLIANCE WITH SEC CHAPTER , "ON-SITE RENEWABLE ENERGY SYSTEMS." MINIMUM DUCT INSULATION LAST UPDATED 10/05/12 DUCT TYPE DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM N -R INSULATION R -VALUE RESID INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R-7 R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE VARIES R-8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY AIR <55' OR >105' WITHI ON ONED SPACE R-3.3 NOT REQ 1,2 1 REFER TO ENERGY CODE SECTIO, 2 FOR FURTHER REQUIREMENTS 2 INSULATED COOLED DUCTS REQUIRED A POR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-7 FOR REST OF INSTALLATION) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM MINIMUM PIPE INSULATION LAST UPDATED: 01/09/13 FLUID DESIGN OPERATING TEMP 'F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING T RUN OUTS* <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER) >350 0.32-0.34 250 4.5 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 1.5 2.0 2.0 2.0 105-140 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER 40-60 0.22-0.28 100 0.5 0.5 0.5 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 <40 0.22-0.28 100 1.0 1.0 1.5 1.5 1.5 2.0 * NOT REQUIRED FOR <1-1/4" HEATING PIPE BETWEEN CONTROL VALVE & COIL, IF <4 FEET FROM COIL ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION $_12 12201 Tuk 98168'; Direction* Si S 120th'Pt: ila ntern'af on al Blvd, Seattle,aVVA'. Ur�(ee Group HeaHh C4-00 L quer, S..120th S[, :S,2Bth st VICINITY MAP NO SCALE SEPARATE PERMIT REQUIRED FOR: .0 Mechanical Electrical Plumbing as Piping lu City of Tukwila ,BUILDING DIVISION, AREA OF WORK SITE MAP NO SCALE ISSUE FOR PERMIT RECEIVED CITY OF TUKV4 SEP 2 0 201 PERMIT CEN Hermanson Hermanson Company LIP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ DIGITAL FORTRESS SABEY DATA CENTER 12201 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 FILE COPY Plan review approval Is subject to errors and omissio Approval of construction documents does not auth^: the violation of any adopted code or ordinance. Pc:x of approved Field Copy and conditions is acknowiedg BY City Of lbkwila r r _ r Revisions ION _ 09/19/13 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0410-02825 Project Number 11-13-02825 Issue Date 09/19/13 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX - HVAC LA M0.00 AM13-Ii(141 s. EXIST MECHANICAL ENCLOSURE/SCREENING 11 1 140 160 T � T I SWR -6 333 CFM (TYP 6) 56x24 RELIEF LOUVER ON TOP 56X24 OSA INTAKE LOUVER ON THE BOTTOM 1 180 T AHU-1 30X12 SCREENED RETURN AIR PARTIAL 1ST FLOOR PLAN - HVAC SCALE: 1/4" = CU -1 EXIST CONC PAD 1F r.0.6E COMPLIANCE APPROVED OCA 04 2013 City of Tukwila BUILDING DIVISION KEY, PLAN SCALE: NONE AREA OF WORK SPLIT SYSTEM AC UNIT SCHEDULE T UPDATED: 09/18/13 OUTDOOR AC UNIT INDOOR AIR HANDLING UNIT UNIT TAG LOCATION SERVES BASIS OF DESIGN COOLING CAP IN BTUH HEATING CAPACITY ELECTRICAL SOUND dBA WEIGHT LBS . UNIT TAG LOCATION SERVES BASIS OF DESIGN SUPPLY CFM OSA CFM ESP IN WG ELEC. HEATER ELECTRICAL WEIGHT LBS REMARKS TOTAL SENS. SEER BTUH HSPF/COP MCA MOCP V/PH WATTS FAN HP FAN FLA V/PH CU -1 PARKING LOT AHU-1 TRANE 4TTA3060 60,000 45,000 1.3.00 N/A N/A 10.0 20 460/3 80 226 AHU-1 UPS ROOM UPS RM TRANE TWE061D400 1,950 NA 4.50 NA 0.75 2.5 460/3 232 1-8 1 FULL AIR ECONOMIZER PROVIDED PER 2012 WA ENERGY CODE SECTION C403.4.1. 2 DUCT MOUNTED SMOKE DETECTOR PROVIDED AND INSTALLED BY THE ELECTRICAL 3 PROVIDE SINGLE POINT POWER CONNECTION. ELECTRICAL WIRING AND DISCONNECT BY ELECTRICAL CO. 4 REFRIGERANT: R -410A. PROVIDE ADDITIO IAL CHARGING OF LINES AS REQUIRED FOR LONG LINE LENGTH APPLICATIONS 5 TERMINATE CONDENSATE AT INDIRECT DRAIN, PROVIDE CONDENSATE PUMP IF NEEDED. 6 PROVIDE ONE INCH THICK THROWAWAY AIR FILTER 7 INSTALL ACCORDING TO MANUFACTURERS INSTALLATION INSTRUCTIONS 8 FOR TRADE COORDINATION REFER TO APPROVED SUBMITTALS 9 UNIT PROVIDED WITH LOW TEMP COOLING OPTION SIDE WALL SUPPLY REGISTER SCHEDULE LAST UPDATED: 09/18/13 UNIT TAG BASIS OF DESIGN MIN. MAIN DUCT SIZE MAX CFM CORE SIZE FACE SIZE MOUNTING MATERIAL REMARKS SRI SHOEMAKER RS34-0 10 120 12 X 4 14 X 6 SURFACE STEEUALUMINUM 1,2 SR2 SHOEMAKER RS34-0 12 160 10 X 6 12 X 8 SURFACE STEEUALUMINUM 1,2 SR3 SHOEMAKER RS34-0 12 200 12 X 6 14 X 8 SURFACE STEEUALUMINUM 1,2 SR4 SHOEMAKER RS34-0 12 230 14 X 6 16 X 8 SURFACE STEEUALUMINUM 1,2 SR5 SHOEMAKER RS34-0 12 250 16 X 6 18 X 8 - SURFACE STEEUALUMINUM 1,2 SR6 SHOEMAKER RS34-0 14 300 14 X 8 16 X 10 SURFACE STEEUALUMINUM 1,2 1 PROVIDE WITH RECESSED SCREWDRIVER OPERATED OPPOSED BLADE DAMPER 2 PROVIDE ALL GALVANIZED FINISH 3 PROVIDE DESIGNER COLOR, VERIFY WITH OWNER PRIOR TO ORDERING t'U3'1 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ISSUE FOR PERMIT Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ DIGITAL FORTRESS SABEY DATA CENTER 12201 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 Revisions _ 09/19/13 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0410-02825 Project Number 1 1-1 3-02825 Issue Date 09/19/13 PARTIAL 1ST FLOOR PLAN & EQUIPMENT SCHEDULES - HVAC M2.R1