Loading...
HomeMy WebLinkAboutPermit M13-188 - BEST KITCHEN - ALTERATIONBEST KITCHEN 569 STRANDER BLVD M13-188 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 1908 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: Project Name: 0223300010 569 STRANDER BLVD BEST KITCHEN MECHANICAL PERMIT Permit Number: M13-188 Issue Date: 1/2/2014 Permit Expires On: 7/1/2014 Owner: Name: Address: IIT ANDOVER DC LLC C/O INDU 518 17TH ST 17TH FL , DENVER, WA, 80202 Contact Person: Name: MICHAEL ATWOOD Address: Contractor: Name: Address: License No: Lender: Name: Address: 9630 153 AV NE , REDMOND, WA, 98052 MERIT MECHANICAL INC. 9630 153 AV NE , REDMOND, WA, 98052 MERITM1163CM III Phone: (425) 883-9224 Phone: (425) 883-9224 Expiration Date: 6/1/2015 DESCRIPTION OF WORK: SUBTYPE: NRES STATUS: PENDING DESCRIPTION: INSTALL (1) SUPPLY FAN WITH MOTORIZED DAMPER AND (2) RELIEF AIR LOUVERS WITH (2) BAROMETRIC RELIEF DAMPERS Valuation of Work: $9,086.00 Type of Work: Fuel type: Fees Collected: $311.81 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: 14 Date: 3 k )-tet 9 • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per. it and agre to the• • nditions attached to this permit. Signature Date: 311117,,hq Print Name: I IU,E-A-a— ki/—X,jj This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL Parcel No: Address: )Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov • City of Tukwila MECHANICAL PERMIT 0223200042 Permit Number: M13-188 530 STRANDER BLVD Project Name: BEST KITCHEN Issue Date: 1/2/2014 Permit Expires On: 7/1/2014 Owner: Name: Address: POLICH FAMILY TRUST C/O ANDOVER MGMT CO 415 BAKER BLVD #200, TUKWILA, WA, 98188 Contact Person: Name: MICHAEL ATWOOD Address: Contractor: Name: Address: License No: Lender: Name: Address: 9630 153 AV NE , REDMOND, WA, 98052 MERIT MECHANICAL INC. Phone: (425) 883-9224 Phone: (425) 883-9224 9630 153 AV NE , REDMOND, WA, 98052 MERITMI163CM Expiration Date: 6/1/2015 DESCRIPTION OF WORK: SUBTYPE: NRES STATUS: PENDING DESCRIPTION: INSTALL (1) SUPPLY FAN WITH MOTORIZED DAMPER AND (2) RELIEF AIR LOUVERS WITH (2) BAROMETRIC RELIEF DAMPERS Valuation of Work: $9,086.00 Type of Work: Fuel type: Fees Collected: $311.81 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: 0/ /02//47 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 11(1-4i AT'ot�))) Date: 117 17,611 - This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL • $13341 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL Applications and plans must be Applications will not Mechanical Permit No. N ` 88 Project No. Date Application Accepted: Date Application Expires: (For office use only) PERMIT APPLICATION complete in order to be accepted for plan review. be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: a2Z32O '' OOy/ Site Address: 530 Strander BLVD Suite Number: Floor: 1 Best Kitchen New Tenant: ❑ Yes ..No Tenant Name: PROPERTY OWNER Name: Michael Atwood Address: 9630 153rd Ave NE Name: Chen, Bob Phone: (425) 883-9224 Fax: City: Redmond State: WA Address: Phone: (425) 883-9224 Fax: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Michael Atwood Address: 9630 153rd Ave NE Address: 9630 153rd Ave NE Phone: (425) 883-9224 Fax: City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: Email: matwood@meritmechanical.com MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc. Address: 9630 153rd Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: Contr Reg No.: MERITMI 163CM Exp Date: 06/01/2013 Tukwila Business License No.: BUS0992852 Valuation of project (contractor's bid price): $ 9,086 Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement ❑ Fuel Type: Electric E Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 1 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAW OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI OWNS R AU = I RIZED GENT: Signature: Print Name: Michael Atwood Mailing Address: 9630 153rd Ave NE H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised R-9-11 docs Revised: August 2011 bh Date: 10/07/2013 Day Telephone: (425) 883-9224 Redmond WA 98052 City State Zip Page 2 of 2 i nCity of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223200042 Address: 530 STRANDER BL TUKW Suite No: Applicant: BEST KITCHEN RECEIPT Permit Number: M13-188 Status: PENDING Applied Date: 10/07/2013 Issue Date: Receipt No.: R13-02831 Payment Amount: $311.81 Initials: WER Payment Date: 10/07/2013 02:59 PM User ID: 1655 Balance: $0.00 Payee: MERIT MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24911 311.61 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 249.45 000.345.830 62.36 Total: $311.81 a o....,.i..t fla Printed: 10-07-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 14/1(-1(9 ° Pro'' _ et.;, E I ti (.()1 e 1-1.11 Type of Inspection: t— NJ A L Addr ss- job'( STRAIJO e Date Called: Special Instructions: Date Wanted: / 3 -24._ / "1 a.m.. p.m. Requester: Phone No:___ �� zD— L'ii4 --- ► 079 `®-Approved per applicable codes. Corrections required prior to approval. CO ME TS: 1J AN31,,Wa6 �-�,� �Date:�Z0 JI rAAJ REINSPECTION FEE REO.UI ED. Prior to nxt inspection, fee must be id at 63 Southcenter Blv.., Suite 100. Call to schedule reinspection. i KIA CO FILE COPY Permit No. 1802 W'Lake Sammamish PKWY SE Bellevue, WA 98008 Phone: 425-644-6400 Cell: 425-351-5999 BEST KITCHEN FAN SUPPORT 569. STRANDER BLVD TUKWILA, WASHINGTON `98188 . FOR ,MERIT MECHANICAL INC. STRUCTURAL: CALCULATIONS' • NIOVEMoER 2;5,,201.3 JOB NO 106-1314: REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 18 2013 PERMIT CENTER EXPIRES ) -/ CORRECTION wt I^ I LTO# L+ a r.l r? �g,3o ,.1 )I'r=I°:,' _'+.r'y 1ItI'-;I1 YcOD 11E1 .01A tI 49q PARTIAL FLOOR PLAN • NOTES:. 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATIONS AT FIELD. 2) CONTRACTOR TO VERIFY ALLEXISTING CONDITIONS PRIOR TO START OF ANY WORK. 3) CONTRACTOR TO VERIFYFAN SIZE, WEIGHT AND LOCATION. PtolecVSubject 141 w..a1w..,....w.�.r... 1, Sheet No. J 3 Date Job No. ) aG—)3l4 Date SheetNo. 3 Job No. ' )1.,/.314 30 )elf L1.✓GL , e'Q►. ›) 0 0 Project/SUbf f-Vev✓/G, i v,/s Date Sheet No. Job No. -e'I )3)* LATERAL DESIGN:(IBC 2012, ASCE 7-10) WIND qz ASIC WIND SPEED EXP. ,'B" Iw = 1.0 Kd= 0.9 Kz = 0.7 Kzf= 1.0 Gf 0.85 110 = 0.00256xKzxKztxKdxV"2xl qz = 19.5 Cf PSF F:= ghxGx:CfxAs G= 0.85 F = 21.56 Af MPH FIG 26.5-1, ASCE 7-10) (TABLE 26.6-1, ASCE 7-10) UP TO 30' (GUST FACTOR) (EQ. 29.3-1) 1.3 (FIG. 29.5-1, ASCE 7-10, FOR:MECHANICAL UNIT) FAN LENGTH (L) = 3.4, FT FAN WIDTH (W) =: .:3.4 . FT FAN DEPTH (D) 3.0 FT SHORT DIRECTION: F wind LONG DIRECTION: F wind = 220 Ibs 220 Ibs EQ. 29.4-1) O' ,a Project/Subject B Date )=) Sheet No., Job No. IA`' -13r best Kitchen, I uKwila, WA MCE . Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = -122.273462 Period MCE Sa (sec) (%g) 0.2 133.7 MCE Value of Ss, Site Class B 1.0 046.0 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS 1, Fv = 1.54 Spectrum for Site Class D Period MCE Sa (sec) (%g) 0.000 053.5 T = 0.0, Sa = 0.4FaSs 0.106 133.7 T = To, Sa = FaSs 0.200 133.7 T = 0.2, Sa = FaSs 0.529 133.7 T = Ts, Sa = FaSs 0.600 118.0 0.700 101.1 0.800 088.5 0.900 078.6 1.000 070.8 T = 1.0, Sa = FvS1 1.100 064.3 1.200 059.0 1.300 054.4 1.400 050.6 1.500 047.2 1.600 044.2 1.700 041.6 1.800 039.3 1.900 037.3 2.000 035.4 SEISMIC :(2012 IBC) ZIP CODE: 98 188 LATITUDE = 47448 LONGITUDE = =422:273 Ss = : 1337 g S1= 0.46g SITE:CLASS: "D' SDCD Fa = 1. •Fv= 1.54. Sms = Fa x Ss 1.337 g S =FvxS1 =: 0.71 g Sds = 2/3 Sms Sd1 =2/3Sm1 = Fp = (0.4 Ap.S.ds.Wp/(Rp/Ip)) / (1 :Apr Ip_ Rp Sds 2.5: 1 6 0.89 0.89 g 0;478 2 Z/H) (EQ. 13.3-1) O• 0 BY Date Job N6. 1 �a6 %3J4 ZJH Wp= 430 lbs Fp = 192 lbs Fp (MAX) = 1.6 Sds.fp.Wp= 613: lbs > Fp O.K. Fp (MIN) = 0.3 Sds.tp.Wp = 115 Ibs:< Fp O.K. (WIND GOVERNS IN BOTH DIRECTIONS) Project/Subject By Sheet No. 03 Dale • Job No. • • )oJ-/3/'Y ✓ ,€)-rU��'aj4'' 441 ofr 0 4 Y Project/Subject e v./14'j By Sheol. 3 Date Job No. " www.hilti.us Profis Anchor 2.4.3 Company:. Specifier: Address: Phone I Fax: E -Mail: Page: 1 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 Specifier's comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 1/2 (3 1/4) Effective embedment depth; het = 3.250 in., No, = 3.625 in. Material: Carbon Steel Evaluation Service Report: ESR -1917 Issued I Valid: 5/1/2013 1 5/1/2015 Proof: design method ACI 318 / AC193 Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plate: I, x ly x t = 3.000 in. x 3.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: Round bars (AISC); (L x W x T) = 0.375 in. x 0.375 in. x 0.000 in. Base material: cracked concrete, 3000, fc' = 3000 psi; h = 6.000 in. Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic Toads (cat. C, D, E, or F) yes (D.3.3.6) Geometry [in.] & Loading [Ib, in.ib] Z Input data and results must be checked for agreement with the existing'cohditiorisand for plausibility! PROFIS Anchor ( c) 2003-2009 HMI AG, FL -9494 Schaan Hits is a registered Trademark of Nilti AG, Schaan www.hilti.us .IlL:1191 Profis Anchor 2.4.3 Company: Specifier: Address: Phone I Fax: E -Mail: Page: 2 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 418 280 0 280 max. concrete compressive strain: - [900] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 418 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] 3 Tension load Load N„a [Ib] Capacity On [Ib] Steel Strength* 418 8029 Pullout Strength* 418 1050 Concrete Breakout Strength** 418 1064 * anchor having the highest loading **anchor group (anchors in tension) 3.1 Steel Strength Nsa = ESR value refer to ICC -ES ESR -1917 + Nsteel z Naa ACI 318-08 Eq. (D-1) Variables n A.e.N [in.1 foci [psi] 1 0.10 106000 Calculations Nsa [Ib] 10705 Results Nsa [Ibl Osumi $ N. [Ibl Nu. [Ib] 10705 0.750 8029 418 3.2 Pullout Strength Npn,t, = Np,2500 Art7500 Npn.i Z Nut) Variables f's [psi] refer to ICC -ES ESR -1917 ACI 318-08 Eq. (D-1) Np.2500 [lb] 3000 4915 Calculations 2500 1.095 Utilization = N18/+Nn Status 6 40 40 Results Npa r [Ib] itconuete 4aeismic .._ . Qnonauc.te 4 Non.l [Ip] N„ a [Ib] 5384 0.650 0.750 0.400 1050 418 OK OK OK Input data and results must be checked for agreement with the existing conditions and for plausib ligiI PROFIS Anchor ( c) 2003.2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan /z3 www.hilti.us 111114®1LOT.i Profis Anchor 2.4.3 Company: Specifier: Address: Phone I Fax: E -Mail: Page: 3 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 3.3 Concrete Breakout Strength Ncb = (ANco) 41.30.1,1 Wc.N Wcp.N Nb 4) Nth Z Nue ANc see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANco = 9 hez r 1 Wec.N=1+2ew)s1.0 3 y/ea N = 0.7 + 0.3 (C.5e.minh) s 1.0 / er Wap N MAX (Ca.min 1.5het) 5 1.0 `` Cac Cac Nb=kcA.4(he Variables ACI 318-08 Eq. (D-4) ACI 318-08 Eq. (D-1) ACI 318-08 Eq. (D-6) ACI 318-08 Eq. (D-9) ACI 318-08 Eq. (D-11) ACI 318-08 Eq. (D-13) ACI 318-08 Eq. (D-7) het [in.] ec1,N [in.] ea2.N [in.] Ca.min 3.250 0.000 0.000 12.000 cee [in.] kc 7.500 Calculations ANc [in.2] 95.06 Results Ncb [Ib].; 5455 17 ANco [in.2] 1 ec1N fc [psi] 3000 rec2,N S(1c.N 95.0 1.000 . . 4concrete 4seismic 0.650 0.750 1.000 4nonductile 0.400 1.000 ed.N c•,N 1.000 1.000 N. [lb] Nab [Ib] Nb [ib] 1064 418 5455 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan www.hilti.us 1■■11`:r1 Profis Anchor 2.4.3 Company: Specifier: Address: Phone I Fax: E -Mail: Page: 4 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 4 Shear load Load Vu, [Ib] Capacity +Vn [Ib] Utilization = Vwf+Vn Status Steel Strength* 280 3572 8 OK Steel failure (with lever arm)* N/A N/A N/A N/A Pryout Strength" 280 2291 13 OK Concrete edge failure in direction W. 280 1325 22 OK * anchor having the highest loading "anchor group (relevant anchors) 4.1 Steel Strength V5eh = ESR value Vsteet Z Vua refer to ICC -ES ESR -1917 ACI 318-08 Eq. (D-2) Variables n A6e,y [in.2) f„„ [psi] 1 0.10 106000 Calculations Vsa [lb] 5495 Results Vsa [lb] 4)steel rp Vee [Ib] 5495 0.650 3572 4.2 Pryout tt1Srengt`)h 1 Vcp — kcp L \ANeo/ Wed.N Wc.N Wcp,N NI] Vcp a VIA AN, see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) Amo = 9 he ylec.N =(:f+1) 5 1.0 3 het Wed,N = 0.7 + 0.3 ( Ca.mtn ) s 1.0 1.5het Wcp.N = MAX(Ca—min 1.5he1) 51.0 Cac Coe Nb =kcX h1i6 Vua [lb] 280 ACI 318-08 Eq. (D-30) ACI 318-08 Eq. (D-2) ACI 318-08 Eq. (D-6) ACI 318-08 Eq. (0-9) ACI 318-08 Eq. (D-11) ACI 318-08 Eq. (D-13) ACI 318-08 Eq. (D-7) Variables ker. hat [in.] ec1.N [in.] ecz.N [in.] ca.min [in.] 2 3.250 0.000 0.000 12.000 Wc,N cac [in.] fc [psi] 1.000 7.500 17 1 3000 Calculations ANc (in•2J ANcO [in.2] Iliac 1,N Wec2.N Wea,N 111cp.N 95.06 95.06 1.000 1.000 1.000 1.000 Results Vcp [lb] 40concrete $seismIc 4nonducate 4 Vcp [lb] Vua [Ib] 10911 0.700 0.750 0.400 2291 280 Nb [Ib] 5455 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 HBO AG, FL -9494 Schoen HMIs a registered Trademark of Hilt AG. Schaan ) 3/ 3 www.hilti.us Profis Anchor 2.4.3 Company: • Specifier: Address: Phone I Fax: E -Mail: Page: 5 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 4.3 Concrete edge failure in direction y+ Ave V`b = (Avco)'I/ed,V wc,V t!/h,V'Yparallel.V Vb ACI 318-08 Eq. (D-21) 4) Vcb 2 Vua ACI 318-08 Eq. (D-2) A. see ACI 318-08, Part D.6.2.1, Fig. RD.6.2.1(b) Avco = 4.5 cet ACI 318-08 Eq. (D-23) 1 Wec,V = 1 + 2e„ 5 1.0 ACI 318-08 Eq. (D-26) 3cat Wed,V = 0.7 + 0.3(1 Scat) <— 1.0 ACI 318-08 Eq. (D-28) 1.5ca.1 lun.v — ha Z 1.0 ACI 318-08 Eq. (D-29) Vb = (7 (tl) 0 i) x l c cess ACI 318-08 Eq. (D-24) a Variables cal [in.] 8.000 Cat [in.] 12.000 ecv [in.] Wc.v ha [in.] 0.000 1.000 6.000 le [in.] da [in.] fc [psi]. 3.250 1.000 0.500 3000 Calculations Ave [in.2] 144.00 Results Vcb [Ib] 6307 Avco [in.2] 288.00 4)conuete 4Iec.V 1.000 yselsmtc. 0.700' 0750 5 Combined tension and shear loads aN 0.398 [3NV=ak/ <=1 t(<paraliel.V 1.000 Wed.V . tyh,v 1.000 1.414 4ndnductue 0.400 Vb [1b1 8920 Vcb [Ib] Vua [Ib] 1325 280 RV Utilization pN,v (%] Status 0.211 5/3 30 OK Input data and results must be checked ter 'agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 HIM AG. FL -9494 Schaan Huh is a registered Trademark of Hihi AG, Schaan www.hilti.us Company: Specifier: Address: Phone I Fax: E -Mail: 1■�II�TI Profis Anchor 2.4.3 Page: Project: Sub -Project I Pos. No.: Date: 6 BEST KITCHEN Fan Attachment 11/26/2013 6 Warnings • To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re -distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! • Condition A applies when supplementary reinforcement is used. The factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-08 Appendix D, Part D.3.3.4 that requires the goveming design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, Part D.3.3.5 requires that the attachment that the anchor is connecting to the structure shall be designed so that the attachment will undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. In lieu of D.3.3.4 and D.3.3.5, the minimum design strength of the anchors shall be multiplied by a reduction factor per D.3.3.6. An alternative anchor design approach to ACI 318-08, Part D.3.3 is given in IBC 2009, Section 1908.1.9. This approach contains "Exceptions" that may be applied in lieu of D.3.3 for applications involving "non-structural components" as defined in ASCE 7, Section 13.4.2. An alternative anchor design approach to ACI 318-08, Part D.3.3 is given in IBC 2009, Section 1908.1.9. This approach contains "Exceptions" that may be applied in lieu of D.3.3 for applications involving 'wall out -of -plane forces" as defined in ASCE 7, Equation 12.11-1 or Equation 12.14-10. • It is the responsibility of the user when inputting values for brittle reduction factors (�nonductite) different than those noted in ACI 318-08, Part D.3.3.6 to determine if they are consistent with the design provisions of ACI 318-08, ASCE 7 and the governing building code. Selection of Anonduct!le = 1.0 as a means of satisfying ACI 318-08, Part D.3.3.5 assumes the user has designed the attachment that the anchor is connecting to undergo ductile yielding at a force level <= the design strengths calculated per ACI 318-08, Part D.3.3.3. Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan I -f Iti is a registered Trademark of Hifi AG, Schaan www.hilti.us mar Profis Anchor 2.4.3 Company: Specifier: Address: Phone I Fax: E -Mail: Page: Project: Sub -Project I Pos. No.: Date: 7 BEST KITCHEN Fan Attachment 11/26/2013 7 Installation data Anchor plate, steel: - Profile: Round bars (AISC); 0.375 x 0.375 x 0.000 in. Hole diameter in the fixture: d! = 0.563 in. Plate thickness (input): 0.250 in. Recommended plate thickness: not calculated Cleaning: Manual cleaning of the drilled hole according 1.500 Anchor type and diameter: Kwik Bolt TZ - CS, 1/2 (3 1/4) Installation torque: 480.001 in.lb Hole diameter in the base material: 0.500 in. Hole depth in the base material: 4.000 in. Minimum thickness of the base material: 6.000 in. to instructions for use is required. ♦y 1.500 to 0 0 o. 1.0 1.500' 1.500 Coordinates Anchor in. Anchor. x 1 0.000 0.000 12.000 12.000 12.000 12.000 o -x Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 I -I Itt AG. FL -9494 Schaan Hilti is a registered Trademark of Hilti AG, Schwan G z3 www.hilti.us 110411671191 Profis Anchor 2.4.3 Company: Specifier: Address: Phone I Fax: E -Mail: Page: 8 Project: BEST KITCHEN Sub -Project I Pos. No.: Fan Attachment Date: 11/26/2013 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilli products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of en -ors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data' and results must bechecked for agreement with the existing Conditions and for plausibility! PROFIS Anchor ( c) 2003-2009 Hulti AG, FL -9494 Schaan HMI is a registered Trademark of Hilti AG, Schaan G ee 0)();,� .G'a•✓G, �,✓�GL Aire 2,4" ‘/'/:'61 ). AL!/'1A• s 4'L •dre)✓'fGxo i g Sheet Date. JoD No. )01—.),31zt h r• iP5 r gid, Vic) �. yam"` ;d,7 .� 7A. r z).9 ,»,'- fir y f-// 4t7 ./f - 2'6m w91i f3E/T G '(z)- /,./ 2-'44;f. fVX8, 6 , )G; 0 c) Q SL ProjecUSubject 9e://' v✓J/A ,: v✓ By Date ))�Zj•-I3' Job No. d —)7)4, APPENDIX SUPPLY FAN SCHEDULE SYMBOL LONE a MODEL DESCRIPTION CFM ESP SO190 UM (LLCM& RRI SONES 0 821. HP V/RI/H2 RFY•M NOTES SF -1 ACRE 0006 SUPPLY PROPELLER FIN 17000 0.00 661 33.0 3 206-3-60 395 I. 2. 3 NOTE: . EQUIPMENT WY BE SUBSTITUTED FOR EQUAL OR BEETER MANUFACTURER 2. WML SNITCH. WAIL NOUSNG. 0000 QED OWPER WEATHER ICOR 3. TRODADSTAT. FAN TO SKIT COIN AT 43'F. 44AT RCM ANGLE BRACKET ALL N SIDES (6).1/444' SOIPSON SOS SCREWS EACH SIDE 29.513• OSECTION A — A SURE: NONE Cita w, =5 MBK 1F11.1 fB/ 0:51 -WARN Ci el, \ FRUIT PROi(cm.% 090050ROC AOXF GtltPER— MANG 17.30 \_MAL, OP CS PCCf BMOMEOBC.RELAY NMPTR--:T \ _PEES/ A'+' DAY �3 UNCON0IIONEO 6900IOUSC SPACE CABISR MATERIALS, COUNTERTOPS 8 MINES STOTMGE n HVAC FLOOR PLAN �V SU& 1/B• - T - 01 IREEEms. `: E15111SG X122 TZITET Al CALSW ise 1. —t [50i400 30.50 Pia tC3I o HVAC ROOF PLAN Sour: l/6• = 1' - 0' COPYRIGHT 90OCE IRIS LAYOUT/FCDOR is AN WH15H NORM. AND HERR uECMAMCAI 9ERE00 RESERVES 53 =DION L. MGM. PURSUANT TO 0811.E 17 SECODN 2 OF THE USA CODE TO PREVENT ANT UNAUTHORIZED COPYING, PUBUCA110N OR USE OF MK 0(904. 4440 TO DUNN OAMAGES THEREFORE. BEST KITCHEN �s s Ra MERIT 6EpUNCAL INC. 9630 19300 AVENUE NE RE50.��7J 02 083-9224 (429) 667-0952 LICENSE: M(RRM1163C4 PZIR6gN6 A. RAO 1.1.= I. role wmAMI 08-01913 HSI 052101550 VIP RN DATE 10-02-2013 AON MOM. 613301 ITTLI HVAC PLAN EOQT M1N91171 0 Coast Products Inc MOTORIZING KIT (OPTIONAL) GUARD 'r0 �' we4G5• Acme Engineering and Manufacturing Corporation P.O. Box 978, Muskogee, OK 74402 Print Date: 8/27/2013 5:09:20 PM DISCONNECT (OPTIONAL) Elevation View A e C 43.25 35.67 40.75 DIMENSIONS (inches) .441ZIY l .1 • D VEP LD, E' Front View A D E 43.25 35.91 43.25 Rough Opening: 41.25 X 41.25 Project:Best Kitchen Location: Customer:Coast Products Inc Architect: Engineer: Contractor: Submitted by.Pat O'Donnell DCK-RWBP Belt Drive Propeller Wall Box Supply Fan Standard Construction Features Adjustable Mounting Angles Aluminum bladed propeller non -overloading design Corrosion resistant fastners Galvanized Wall Box Heavy gauge charcoal baked enamel with UV inhibitors coaled steel frame/orifice base Motor beatings are permanently lubricated unless special motor requirements are specified Motorized Backdraft damper OSHA Approved Motor Side Guard, Galy Pre -lubricated bearings in duplex split pillow block housing rated at L-50 life of 200,000 hours - 5 -year limited warranty Static resistant belts Two-year limited fan/motor warranty W/ Variable pitch drives designed for 1.5 Service Factor Options & Accessories Damper Motor 230/1/60 AWH - AWH - for Motorized Damper Less Disconnect and Wiring W HP36DC/DCK Weather Hood DCK-R36W8P 3 Hp 200/Three Phase/60 Hz/ODP 1 Speed Energy Efficient - Table 12-11 Motor RPM: 1750 Damper Motor 230/1/60 AWH -AWH - for Motorized Damper Less Disconnect and Wiring PERFORMANCE (Altitude = 0 ft, Temperature = 68 Degrees F, Density = 0.075 Ib/R3) Includes Belt Drive Loss Qty Model Size 1 DCK-R36WBP Volume (cfm) SP (In wg) Power (bhp) Speed (rpm) TS (fpm) OV (fpm) Weight (lbs) 17000 0.000 2.375 775 '7304 2335 202.00 SOUND ('In free space @ 5 feet / 1.5 Meters) Motor Info. Fan Rating: CSA HP Volts Phase Hz End RPM SpfWdg 3 200 3 60 ODP 1750 1SPD Octave 1 2 3 4 5 6 7 8 LwA dBA" Sones' Static c Eff Total Eff Sound 92.6 93.4 91.5 87.5 83.5 80.3 76.5 69.2 89.9 78.4 26 0.00 40.20 Power 0 mn MOVEMENT RUES (ONTAOL AssoomTo4 INIERNAtt0NR1, IN Static Pressure (in wg) 1.80 - - I .� I ... I . _. 1.60-- I I i l ); 1.40- " _ .. i ,::.. 1.20.I. .``...__.L. - t 1.00 1 - -- r . _ I _ - - ! 1` .-T...&�r_-,., 0.80- I �_ .. t I. ..�......4 i.... 0.60 __..... - . �. _. I •1 ... ...... .- I 0.40 r - I 0.20-....._ - -I- -• - - . 1'. 1 I1.' I 0.00 -'ti --r- .4. . ,, -- r-- --r- - t The sound ratings shown are oudness values In spherical sones et 1.5 m (59) In a spherical free field calculated per Annex B of AMCA 311. Values shown are far Installation Type A: free Inlet spherical sone levels. The AMCA certified ratings seal applies to sone ratings only. -5.0 -4.5 -4.0 3.5 - 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 4000 8000 12000 • 16000 2000 6000 10000 14000 Flow (cfm) - Performance -•-• System • Operating Point Power Min. Performance • Operating Power Manufacturer reserves the right to change specifications without notice. These are typical drawings for dimensional purpose only and are Correct within limits for normal installation requirements. They do not necessarily show actual construction 8/27/2013 5:09:20 PM Coast Products Inc Acme Engineering and Manufacturing Corporation P.O. Box 978, Muskogee, OK 74402 Print Date: 8/2712013 5:09:20 PM Project:Best Kitchen Location: Customer:Coast Products Inc Architect: Engineer. Contractor: Submitted by.Pat O'Donnell End View G H J 38.25 40.00 38.25 40.00 DIMENSIONS (inches) , WHP36DC/DCK Weather Hood Qty Model Size 1 WHP36DC/DCK Elevation View F G H 29.48 38.25 40.00 WHP Weather Hood Package Standard Construction Features Galvanized steel construction Shipped knocked down for field assembly Two-year limited fan/motor warranty With field mounted guard Weight (lbs) 145.00 Manufacturer reserves the right to change specifications without notice. These are typical drawings for dimensional purpose only and are correct within limits for normal Installation requirements. They do not necessarity stow actual construction 8/27/2013 5:09:20 PM , ��lILA I.I, ,r,J qs yi Tukwila City of October 18, 2013 Michael Atwood Merit Mechanical 9630 153 Av NE Redmond, WA 98052 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Mechanical Permit Application Number M13-188 Best Kitchen — 530 Strander BI Dear Mr. Atwood, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. M13-188 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • . Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: October 15, 2013 Project Name: Best Kitchen Permit #: M13-188 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. The plan shows ventilation fan installed with two exhaust vents at the opposite end of the building for apparently ventilation of that space. The plans do not specify if this is a conditioned space or how the ventilation shall comply with Washington State Energy code (WSEC). Since this apparently a conditioned space, by this installation, all conditioned air would be exhausted to the exterior. Specify what the purpose the ventilation serves. Provide information about the buildings envelope and the conditioning of the different spaces most particularly this space. Specify what this space is used for. Since this is an alteration of a conditioned space, an analysis of the space shall be required to show compliance with Washington State Energy codes. Proved a 2012 WSEC building envelope compliance form or a Building performance analysis to show how the new ventilation system shall comply with WSEC. (2012 WSEC C401, C402, C407, C408...) 2. Where the new vents are to be installed in the exterior walls, provide construction details with specifications for the alteration of the wall framing for the new openings. An engineer's analysis with details shall be required for openings affecting any load bearing or sheer walls i.e. the two south -end side wall panels. Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. °PERM9T COORD COPY 411 PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-188 DATE: 12/18/13 PROJECT NAME: BEST KITCHEN SITE ADDRESS: 530 STRANDER BLVD Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: k L 6 -kc, Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS:. (Tues., Thurs.) DUE DATE: 12/19/13 Complete 1% Incomplete 111 Not Applicable 111 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions[X( Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 01/16/14 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: • PERMIT COORD COPD PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-188 PROJECT NAME: BEST KITCHEN SITE ADDRESS: 530 STRANDER BL X Original Plan Submittal Response to Correction Letter # DATE: 10-07-13 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building&15,14 1C4(0-4) A)//1-- 'vision Fire Prevention 1111111 Planning Division Public Works Structural n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-08-13 Complete Comments: Incomplete Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg D Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11-05-13 Not Approved (attach comments) IX DATE: Permit CenteriUse Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 03/12/2014 Response to Incomplete Letter # Response to Correction Letter # ✓ Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: M13-188 Project Name: Best Kitchen Project Address: 530 Strander BLVE (to be changed) Contact Person: Michael Atwood Summary of Revision: Revise site address from 530 Strander BLVD to 569 Strander BLVD Phone Number: (425) 883-9224 RECEIVED erry OF TUK1Anuk MAR 12 MN PERMIT OBITEP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: ® ---Entered in Permits Plus on ( H:\Applications\Forms-Applications On Line \2010 Applications\7-2010 - Revision Submittal.doc Revised: May 2011 City of Tuk*ila, ofC6fidlity•Dolielopment 6300`SOuilicenter Boulevard, Suite #100 Tukwila, Washington. 98188 Phone: 206-43 I-3670 Fax :206431,-3665 REVISION SUBMITTAL Rgvision submittals must lie submitted In personal thePermit Center. Revisions will no be accepted through 'the mail; fax, etc; Date: Plan Cheekfilm-mit Number IVI13-188 El Response to Incomplete Letter # • Response to Correction Letter ii 1 El Revision.# after Permitis Issued. ▪ Revision tequdsted by a City Building Inspector or -Plans Examiner Reognie,,, Irry ni.-4:741A DEC 1 8 2013 °5E1411r CENTER Project Name: Best Kitchen PrOjeet' Add kei§: 53aStrander BI. ContaitPoziOni, 01 I efigL.... At-LoiA7b Phone,Namber is") sc63 -61 2.-z_y Summary of Revision; Plans are revised toshowcorrectedaddress and site l„ The. 2,SideVirall relief air louvers are deleted. Building has 2, existing. relief hoods on roof. Structural calculations is provided for supply fan, Sheet Number(s): _. . "Cloud" or highlight all areas of revision including 4004 revision: i, Received at the City of Tukwila Pemiitt nter by: Or Entered' in.Perinits:PhiSbn 1applicatipnAlonns-applications on lindrevision'spbrrOtO Created: 841:2604 Revised: MERIT MECHANICAL INC ll Washington State Department of Labor & Industries Page 1 of 3 MERIT MECHANICAL INC Owner or tradesperson KIRKWOOD, RODERICK V Principals KIRKWOOD, RODERICK V JOAN KIRKWOOD WILLIAM FRICKBERG Doing business as MERIT MECHANICAL INC WA UBI No. 600 517 946 9630 153rd Avenue NE REDMOND, WA98052 425-883-9224 KING, County Business type Corporation Governing persons JOANKIRKWOOD License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. .............................. Meets current requirements. License specialties GENERAL License no. MERITMI163CM Effective — expiration 02/14/1984 — 06/01/2015 Bond FIDELITY & DEPOSIT CO OF MD Bond account no. 08358695 Received by L&I 01/20/2010 Insurance Travelers Indemnity Co of Ame Policy no. VTC2JCO828K6148TIL13 Received by L&I 09/26/2013 Savings No savings accounts during the previous 6 year period. $12,000.00 Effective date 02/01/2010 $2,000,000.00 Effective date 11/01/2013 Expiration date 11/01/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600517946&LIC=MERITMI163CM&SAW= 01/02/2014 GENERAL NOTES 1. COORDINATE ALL NEW WORK WITH STRUCTURE AND OTHER TRADES. 2. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 3. ALL LINE VOLTAGE WORK SHALL BE BY ELECTRICIAN. 4. A 120 -VOLT SERVICE RECEPTACLE SHALL BE LOCATED WITHIN 25OF EACH PIECE OF EQUIPMENT. DISCONNECT SHALL BE BY ELECTRICAL CONTRACTOR. 5. HVAC SYSTEMS HAVE BEEN DESIGNED PER THE REQUIREMENTS OF 2012 WSEC, IBC AND IMC. CODE COMPLIANCE NOTES MOTORIZED AND GRAVITY DAMPERS SHALL BE PROVIDED AS REQUIRED BY 2012 WSEC SECTION C403.2.4.4, INCLUDING MAXIMUM LEAKAGE RATES IN ACCORDANCE WITH 2012 WSEC C402.4.5.2. 2. MAINTAIN 10'-O" MINIMUM • DISTANCE BETWEEN OSA INTAKES AND PLUMBING VENTS, EXHAUST AND COMBUSTION AIR OUTLETS. 3. PROVIDE SEISMIC BRACING. AND SUPPORTS IN ACCORDANCE WITH 2012 IBC FOR SEISMIC DESIGN CATEGORY D AND BASED ON AN IMPORTANCE FACTOR OF 1.0 FOR ALL SYSTEMS, EXCEPTING • THE GAS PIPING SHALL HAVE AN IMPORTANCE FACTOR OF 1.5. HVAC - LEGEND m 0 0 N RG - 100 CD - 100 EG - 100 SLSM FC SFD FD SD VD MD 1!1!1!1!1! AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP, ROUND OR RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP, ROUND OR RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN, ROUND OR RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN, ROUND OR RECTANGULAR RETURN AIR GRILLE, NUMBER INDICATES CFM QUANTITY SUPPLY AIR DIFFUSER, NUMBER INDICATES CFM QUANTITY EXHAUST AIR GRILLE, NUMBER INDICATES CFM QUANTITY EXISTING DUCTWORK SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION COMBINATION FIRE AND SMOKE DAMPER FIRE DAMPER SMOKE DAMPER VOLUME DAMPER MOTORIZED DAMPER GENERAL LEGEND NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES 11111111111111111 FLEX DUCT --0—EQUIPMENT TAG TYPE EQUIPMENT TAG NUMBER --44—DETAIL OR DIAGRAM NUMBER -ml--SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN --�SECTION LE.IIER ------SHEET NUMBER WHERE SECTION IS SHOWN D / ' REVISION CLOUD AND CHRONOLOGICAL NUMBER 1 DETAIL REFERENCE OUTLINE POINT OF CONNECTION . TO EXISTING OR TO OTHERS' WORK COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF FINAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY PER 2012 WASHINGTON STATE ENERGY CODE (WSEC) SECTION C408.1.3.1. AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WTIH 2012 WSEC SECTION C408.1.3.2. ABBREVIATIONS 0 ABV AD AFF AHU AP BF BFC BOT CD CFM CG CIP CLG CONC CONN. CTG CW CWSFU DB DFU. DIAMETER ABOVE ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ACCESS PANEL BELOW FLOOR BELOW FINISHED CEILING BOTTOM CEILING DIFFUSER CUBIC FEET PER MINUTE CEILING GRILLE CAST IN PLACE CEILING CONCRETE CONNECTION CEILING TRANSFER GRILLE COLD WATER COLD WATER SUPPLY FIXTURE UNITS DRY BULB DRAINAGE FIXTURE UNITS DIA DN DWG EA EAT EQUIP ESP EWT EXH FCO FF FLR FPM FT FUT GAL GALV, GR HP HT HVAC DIAMETER DOWN DRAWING EACH ENTERING AIR TEMPERATURE EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST FLOOR CLEANOUT FINISHED FLOOR FLOOR FEET PER MINUTE FOOT OR FEET FUTURE GALLON GALVANIZED GRILLE HORSEPOWER HEIGHT HEATING, VENTILATION AND AIR-CONDITIONING HW HWG HWR HWRR HWS HWSFU HWTG IBC ID IE IMC IN IN WG LBS LIN FT LWG LWR MAX MBH MD MIN HOT WATER HIGH WALL GRILLE HEATING WATER RETURN HEATING WATER REVERSE RETURN HEATING WATER SUPPLY HOT WATER SUPPLY FIXTURE UNITS HIGH WALL TRANSFER GRILLE INTERNATIONAL BUILDING CODE INSIDE DIAMTER INVERT ELEVATION INTERNATIONAL MECHANICAL CODE INCHES INCHES WATER GAUGE POUNDS LINEAR FOOT OR FEET LOW WALL GRILE LOW WALL REGISTER MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MOTORIZED DAMPER MINIMUM MOCP MTD N/A NC NO OBD OD OSA PCF PH POC PSI PSIG RA REG REQ'D RFA RPBP RPM SA SBC MAX OVER CURRENT PROTECTION MOUNTED NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN OR NUMBER OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION OUTSIDE AIR POUNDS PER CUBIC FOOT PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE RETURN AIR REGISTER REQUIRED RELIEF AIR REDUCED PRESSURE BACKFLOW.PREVENTER REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE BUILDING CODE SEC SOG SMC SL SEATTLE ENERGY CODE SLAB ON GRADE SEATTLE MECHANICAL. CODE SOUND LINED SMACNA SHEET METAL AND AIR-CONDITIONING CONTRACTOR'S NATIONAL ASSOCIATION SQUARE. FOOT OR FEET STAINLESS. STEEL TOTAL DYNAMIC HEAD TRANSFER GRILLE TYPICAL UNLESS NOTED OTHERWISE UNIFORM PLUMBING CODE VENT THROUGH ROOF WATTS OR WIDTH WITH WITHOUT WET BULB WALL CLEANOUT WATER GAUGE WASHINGTON STATE ENERGY CODE WATER SUPPLY FIXTURE UNITS SQ FT SS TDH TG TYP UNO UPC VTR W W/ W/O WB WCO WG WSEC WSFU LEGAL DESCRIPTION TAX PARCEL NUMBER: 022330-0010 ANDOVER INDUSTRIAL PARK #4 LESS UP RR OPER R/W Plat Lot: TR 1 BUILDING INFORMATION ZONING: CONSTRUCTION TYPE: OCCUPANCY TYPE: TUC MASONRY, SPRINKLER WAREHOUSE BUILDING OWNER IIT ANDOVER DC LLC C/O INDU REVISIONS No chongoa shell be made to the scope of work without prior approval of Tukwila Building Division. NOT : Revisions will require a new plan submittal ond may include additional plan review fees. ' SEPARATE PERMIT REQUIRED FOR: ❑ MethanIcal Irtlectdoal lumbing 1� as Piping City of Tukwila BtOLDING DIVISION VICINITY MAP MECHANICAL SCOPE INSTALL 1 SUPPLY FAN WITH MOTORIZED DAMPER. FILE COPY Permit NO.US**"..185 Plan review approval Is to ns. A,. ; al of construction documents does not authorize or, , _ation of any adopted or ordinance. Receipt S)1 approved Fielopy BY Dato:i ZZ -"J o City Of BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2Q13 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 18 2013 PERMIT CENTER 3ORRECfON COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. BEST KITCHEN 569 STRANDER BOULEVARD TUKWILA, WA 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND, WA 98073 24 FAX (42 8 5)867 -0962 LICENSE: MERITMI163CM REVISIONS 0. FOR PERMIT 10-03-2013 1. PERMIT CORRECTION 11-01-2013 VW DESIGNED VTD CHECKED RK DATE 10-02-2013 JOB NUMBER 813341 SHEET TITLE COVER. SHEET SHEET NUMBER M�Q,�QO A1-0F-3 COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 0 -J 2 0 000. z g D MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND, WA 98073 (425) 883-9224 FAX (425) 867-0962 LICENSE: MERITMI163CM REVISIONS 0. FOR PERMIT 1. PERMIT CORRECTION 10-03-2013 11-01-2013 WD DESIGNED VTD REVIEWED FOR CODE COMPLIANCE APPROVED SCALE: 1/64' RECEIVED CITY OF TUKWILA DEC 18 2013 PERMIT CENTER JOB NUMBER 813341 SHEET, TITLE SITE PLAN ELECTRICAL SYMBOL MAKE & MODEL ACME DCK36 DESCRIPTION ® DIST. WEIGHT SUPPLY PROPELLER FAN NOTE: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER : MANUFACTURER. 2. WALL. SWITCH, WALL HOUSING, MOTORIZED DAMPER, WEATHER HOOD. 3. ' THERMOSTAT, FAN TO SHUT DOWN AT 45°F. COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA. CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. EXISTING 75 NBH INPUT UNIT HEATER FOR FREEZE PROTECTION Z . LU C.) LU CD STRANDER BOULEVARD rn (0 CO 03 03 o) BAROMETRIC RELIEF DAMPER BAROMETRIC RELIEF DAMPER UNCONDITIONED WAREHOUSE SPACE CABINET MATERIALS, COUNTERTOPS & GRANITES STORAGE MERIT MECHANICAL INC... 9630 153RD AVENUE NE REDMOND, WA 98073 24 FAX (425) 92 86 0962 LICENSE: MERITMI163CM UNCONDITIONED SPACE REVISIONS 0. FOR PERMIT 10-03-2013 1: PERMIT CORRECTION 11-01-2013 VTD EXISTING 30x30 RELIEF AIR ON ROOF JOB NUMBER 813341 SHEET TITLE HVAC PLAN