HomeMy WebLinkAboutPermit M13-189 - JORGENSEN FORGE - ALTERATIONJORGENSEN FORGE 8531 EAST MARGINAL wys M13-189 City ogukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0001600023 Address: 8531 EAST MARGINAL WY S TUKW Project Name: JORGENSEN FORGE Permit Number: M13-189 Issue Date: 10/25/2013 Permit Expires On: 04/23/2014 Owner: Name: JORGENSEN FORGE CORP Address: C/O DOUG JAMES , 8531 E MARGINAL WAY S 98108 Contact Person: Name: DAVID SWEAT Address: 3602 S PINE ST , TACOMA, WA 98409 Email: DAVIDS@ASEI.WS Contractor: Name: AIR SYSTEMS ENGINEERING INC Address: 909 S 28 ST , TACOMA, WA 98409 Contractor License No: AIRSYE*229KN Phone: 253-572-9484 Phone: 206 628-9484 Expiration Date: 02/01/2014 DESCRIPTION OF WORK: INSTALL DUCTLESS SPLIT AIR CONDITIONERIN SERVER ROOM Value of Mechanical: $5,781.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $261.56 International Mechanical Code Edition: 2012 Date: (a/gS�j3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Jed a Ste✓ e 7- 1-1/ Si/ - rf tom - 4L,-<7.=> This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. roan AM" KA1 Z_1 A0 Printar1• is • • PERMIT CONDITIONS Permit No. M13-189 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-189 Printed: 10-25-2013 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. M A 3-1 9 Project No. Date Application Accepted: Date Application Expires: w-.-w—t3 (For o/%ice use only) 1-1 MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Doo f l o A o 2 3 Site Address: e S 3 I ,EAs r iy q ,QG /,,, a c L,jy S Suite Number: Floor: Tenant Name: .Te2 • FPQ� PROPERTY OWNER Name: 3o IL 6-i-cds o -./ %'o 2 it r o Gt p Address: o' C,,?/ £ A-4Z6/.v,¢t i..41.5-. City: State: Zip: SOAT r e. J7 w4_ 5$ to 9 CONTACT PERSON - person receiving all project communication Name: D4 v,o S -4,,e,1( r (Cr'4e Address: ...?Co a s /°/.) ic s .T City:State: T 4Co,-,At A,� Zip: ss yo Phone: Fax: .2S3 S72 - 9 VB Y .0 S3 .762-03 3 7 Email: v, .-/ . < AD 4-. ' .z. w f New Tenant: ❑ Yes [Y.No l'IECIIANICAL CONTRACTOR INFORMATION Company Name: O ft Cy CT s r.t, 4 /-rd eoc2:.cd 6 Address: 2C.o.2 --C tz.i, e Sr City: State: Zip: %Jl'o�4 4/475 rpS Phone: Fax: .P S-3 c 7.2 - 5 vs) y 0.,.§-3 3.6 3 .6" 7 Contr Reg No.:Exp Date. 9TQs, t bac Y K4) o2A/,2 O/ y Tukwila Business License No.: /30 s- 4 cjq y c 8 1 Valuation of project (contractor's bid price): $ S 7 '/ Describe the scope of work in detail: Si4vc eo, / ti SIf / G SIS —C.D I d. T I / £ .e /( /A) Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric g Gas ❑ Other: Page 1 of 2 H:\Applications\Forms-Applications On Lme\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHQRIZED AGENT: Signaturo.— Print Name: .D,4 v fe (4)/2- a..,s z.v, l Mailing Address: ?Co -S- /Di .. Q S'T H:\Applicattons\Forms-Applications On Lme\201 I Apphcations'Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Date: / o /9/ /3 Day Telephone: 2 S3 .5- 7 a- S V 6 j/ 74 A -- City 4/2 516 Yp 5 State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0001600023 Permit Number: M13-189 Address: 8531 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 10/10/2013 Applicant: JORGENSEN FORGE Issue Date: Receipt No.: R13-02969 Initials: LAW User ID: 1632 Payment Amount: $194.17 Payment Date: 10/25/2013 09:32 AM Balance: $0.00 Payee: AIR SYSTEMS ENGINEERING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 62499 194.17 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 194.17 Total: $194.17 rtnr• Re int-nf Printed: 10-25-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0001600023 Permit Number: M13-189 Address: 8531 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 10/10/2013 Applicant: JORGENSON FORGE Issue Date: Receipt No.: R13-02856 Payment Amount: $15.08 Initials: WER Payment Date: 10/10/2013 01:30 PM User ID: 1655 Balance: $194.17 Payee: AIR SYSTEMS ENGINEERING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 62407 15.08 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 15.08 Total: $15.08 __ crintpr• 1n_1n_2n1� • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0001600023 Permit Number: M13-189 Address: 8531 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 10/10/2013 Applicant: JORGENSON FORGE Issue Date: Receipt No.: R13-02855 Initials: User ID: WER 1655 Payment Amount: $52.31 Payment Date: 10/10/2013 01:29 PM Balance: $209.25 Payee: AIR SYSTEMS ENGINEERING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 62407 52.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 52.31 Total: $52.31 Printed• 10-10-2013 INSPECTION RECORD. Retain a copywith permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 - Mia -(1 Projjeec_t:. —I ©,2;G e. vseN l 16, F - Type of Inspe tion: -- , kA e.e.- F. AI vs'�---''. Address:Date led .3-1040..c--2-476 Special Instructions: OUaie,Ss VI, - et. ivy`- S:l2 E (;fin-d�f� - i (P f02y` l g` Date Wanted: c5V'T:7: )Irr 1 -1O - Requester: 6A J26K _s --(ie AZ Phoi_s 3_ s'? Z -94S)4 9-t'O)4 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: - MIC- fr, ci-e— -.-;.k•A A -f ;\./r -o J <n( ----r;',/‘ a LC /`(ff,'e .e/ A i , 34 I i C Inspec or: Date: I I .� ,1 ' �3 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - Submittal Data: System 18CL ASU18CL & AOU18CL Job Name: ,j--0&& C.vs-o.,, PD 4 .0 Location: FILE COPY FUJITSU se ox %ZQP...t Purchaser: A Q S7 ST ,.rS r.c. C/.v LC 41 .v /-v C. Engineer: 17, Submitted To: Submitted By: For: 111 Reference ❑ Approval ❑ Construction Capacities: Cooling Min/Max Cooling Outdoor Design Temperature F° DB/WB SEER EER Low Ambient Temp. F° Voltage/Frequency/Phase Indoor Unit: 18,000 BTU/h 5,500/19,000BTU/h 95/75 19.0 10.4 14 208-230/60/1 Noise Level db (A) - H/M/L/Q Weight Outdoor Unit: Noise Level db (A) 44/38/32/25 20 lbs. 50 Recommended Fuse Size 20A Min. Ampacity 16A Running Current (Rated/Max) 7.7/9.0 Weight a OUTLINE AND DIMENSIONS 31_1/8• 31.1!8" 2-9118' Standard Features: 88 lbs. • Six year compressor warranty Refrigerant Piping: Max Ht. Difference Max Total or Combined Length Discharge Vapor Line (O.D.) Suction (O.D.) Note: Figures are based on 230 Volts REVIEWED FOR CODE COMPLIANCE APPROVED - OCT 212013 otes: City of Tukwila BUILDING DIVISION 49 ft. 66 ft. 1/4 in. 1/2 in. • Two year parts warranty • Refrigerant R410A • Auto Mode; Quiet Mode • Auto Louver: Up/Down • Apple Catechin Filter • Auto Changeover • Digital Wireless Remote Control M(3-18? 11-13118" • Sleep timer; 24 hour timer • Built in Low Ambient • Auto Restart/ Reset • Dry Mode; Coil Dry Mode • Cold Prevention • Ion Deodorizing Filter • Optional Wired Remote Control RECEIVED CITY OF TUKWILA OCT IU2013 PERMIT CENTER EVE . Egamosia i----1 1®111NIIitiMa_MI® Standard Features: 88 lbs. • Six year compressor warranty Refrigerant Piping: Max Ht. Difference Max Total or Combined Length Discharge Vapor Line (O.D.) Suction (O.D.) Note: Figures are based on 230 Volts REVIEWED FOR CODE COMPLIANCE APPROVED - OCT 212013 otes: City of Tukwila BUILDING DIVISION 49 ft. 66 ft. 1/4 in. 1/2 in. • Two year parts warranty • Refrigerant R410A • Auto Mode; Quiet Mode • Auto Louver: Up/Down • Apple Catechin Filter • Auto Changeover • Digital Wireless Remote Control M(3-18? 11-13118" • Sleep timer; 24 hour timer • Built in Low Ambient • Auto Restart/ Reset • Dry Mode; Coil Dry Mode • Cold Prevention • Ion Deodorizing Filter • Optional Wired Remote Control RECEIVED CITY OF TUKWILA OCT IU2013 PERMIT CENTER Air System Sizing Summary for 2nd Floor Project Name: jorgenson forge minisplit Prepared by: Dave Sweet 10/09/2013 01:42PM Air System Information Air System Name 2nd Floor Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Central Cooling Coil Sizing Data Total coil load Total coil load Sensible coil load Coil CFM at Aug 1500 Max block CFM ... . Sum of peak zone CFM Sensible heat ratio ft2/Ton BTU/(hr-ft2) Water flow @ 10.0 °F rise 0.7 Tons 9.0 MBH 9.0 MBH 431 CFM 431 CFM 431 CFM 1.000 106.8 112.4 1.80 gpm 5.2 MBH 431 CFM 431 CFM 0.52 gpm 431 CFM 424 CFM 5.39 CFM/ft2 5 CFM 0.06 CFM/ft2 Central Heating Coil Sizing Data Max coil load Coil CFM at Des Htg Max coil CFM Water flow @ 20.0 °F drop Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2 FILE COPY Number of zones Floor Area 80.0 ft2 Location Seattle IAP, Washington 1 Calculation Months Jan to Dec Sizing Data Calculated Load occurs at Aug 1500 OA DB/WB 82.0/66.0 °F Entering DB / WB 80.0 / 65.4 °F Leaving DB / WB 60.4 / 58.6 °F Coil ADP 58.2 °F Bypass Factor 0.100 Resulting RH 46 % Design supply temp. 58.0 °F Zone T -stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Load occurs at BTU/(hr-ft2) Ent. DB / Lvg DB 68.3/79.7 °F Des Htg 65.3 Fan motor BHP Fan motor kW Fan static 0.00 BHP 0.00 kW 0.00 in wg CFM/person 0.00 CFM/person REVIEWED FOR :BODE COMPLIANCE APPROVED OCT 21 2013 • City of Tukwila BUILDING DIVISION 89 RECEIVED CITY OF TUKWILA OCT 1 U 2013 PERMIT CENTER Hourly Analysis Program v4.61 Page 1 of 6 • Zone Sizing Summary for 2nd Floor Project Name: jorgenson forge minisplit Prepared by: Dave Sweet 10/09/2013 01:42PM Air System Information Air System Name 2nd Floor Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Zone Sizing Data Number of zones 1 Floor Area 80.0 ft2 Location Seattle IAP, Washington Calculation Months Jan to Dec Sizing Data Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Zone 1 9.2 431 431 Jul 1500 5.2 80.0 5.39 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 2nd Floor 1 9.2 Jul 1500 431 5.2 80.0 5.39 Hourly Analysis Program v4.61 Page 2 of 6 Air System Design Load Summary for 2nd Floor Project Name: jorgenson forge minisplit Prepared by: Dave Sweet 10/09/2013 01:42PM Hourly Analysis Program v4.61 Page 3 of 6 DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB I WB 82.0 °F 166.0 °F HEATING DATA AT DES HTG HEATING OA DB I WB 24.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 120 ft2 14 - 120 ft2 219 - Roof Transmission 120 ft2 159 - 120 ft2 374 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 80 W 220 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 2110 W 7199 - 0 0 - People 0 0 0 0 0 0 Infiltration - 340 1 - 3910 0 Miscellaneous - 0 0 - 0 0 Safety Factor 15% / 0% 1190 0 15% 675 0 » Total Zone Loads - 9122 1 - 5179 0 Zone Conditioning - 8982 1 - 4995 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 431 CFM 0 - 431 CFM 0 - Ventilation Load 5 CFM 10 0 5 CFM 228 0 Supply Fan Load 431 CFM 0 - 431 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 8992 1 - 5223 0 Central Cooling Coil - 8992 0 - 0 0 Central Heating Coil - 0 - - 5223 - » Total Conditioning - 8992 0 - 5223 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.61 Page 3 of 6 Project Name: Jorgenson forge minisplit Prepared by: Dave Sweet System Psychrometrics for 2nd Floor 10/09/2013 01:42PM August DESIGN COOLING DAY, 1500 TABLE 1: SYSTEM DATA Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTU/hr) Latent Heat (BTU/hr) Ventilation Air Inlet 82.0 0.01021 5 400 10 0 Vent - Return Mixing Outlet 80.0 0.01021 431 445 - - Central Cooling Coil Outlet 60.4 0.01021 431 445 8992 0 Central Heating Coil Outlet 60.4 0.01021 431 445 0 - Supply Fan Outlet 60.4 0.01021 431 445 0 - Cold Supply Duct Outlet 60.4 0.01021 431 445 - - Zone Air - 80.0 0.01021 431 446 8982 1 Return Plenum Outlet 80.0 0.01021 431 446 0 - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 9122 Cooling 8982 80.0 431 446 0 0 Hourly Analysis Program v4.61 Page 4 of 6 Project Name: jorgenson forge minisplit Prepared by: Dave Sweet System Psychrometrics for 2nd Floor 10/09/2013 01:42PM WINTER DESIGN HEATING TABLE 1: SYSTEM DATA Component Location Dry -Bulb Temp (°F) Specific Humidity (Ib/Ib) Airflow (CFM) CO2 Level (ppm) Sensible Heat (BTU/hr) Latent Heat (BTU/hr) Ventilation Air Inlet 24.0 0.00103 5 400 -228 0 Vent - Return Mixing Outlet 68.3 0.00103 431 796 - - Central Cooling Coil Outlet 68.3 0.00103 431 796 0 0 Central Heating Coil Outlet 79.7 0.00103 431 796 5223 - Supply Fan Outlet 79.7 0.00103 431 796 0 - Cold Supply Duct Outlet 79.7 0.00103 431 796 - - Zone Air - 68.8 0.00103 431 800 -4995 0 Return Plenum Outlet 68.8 0.00103 431 800 0 - Air Density x Heat Capacity x Conversion Factor: At sea level = 1.080; At site altitude = 1.063 BTU/(hr-CFM-F) Air Density x Heat of Vaporization x Conversion Factor: At sea level = 4746.6; At site altitude = 4670.1 BTU/(hr-CFM) Site Altitude = 449.0 ft TABLE 2: ZONE DATA Zone Name Zone Sensible Load (BTU/hr) T -stat Mode Zone Cond (BTU/hr) Zone Temp (°F) Zone Airflow (CFM) CO2 Level (ppm) Terminal. Heating Coil (BTU/hr) Zone Heating Unit (BTU/hr) Zone 1 -5179 Heating -4995 68.8 431 800 0 0 Hourly Analysis Program v4.61 Page 5 of 6 Psychrometric Analysis for 2nd Floor Project Name: jorgenson forge minisplit Prepared by: Dave Sweet 10/09/2013 01:42PM Location: Seattle IAP, Washington Altitude: 449.0 ft. Data for: August DESIGN COOLING DAY, 1500 1: OUtdQorr.Air 5tOiral ooii COutlet . ooVA an Ut1 leYoil 30 1 40 50 60 70 Temperature ( °F ) 80 90 100 0.020 0.018 0.016 0.014-2 C) 0.012 n c 0.010 5. a 0.008 Er 0.006 0.004 0.002 0.000 Hourly Analysis Program v4.61 Paae 6 of 6 • PLAN FiNiC/9�'`MING SLIP ACTIVITY NUMBER: M13-189 DATE: 10-10-13 PROJECT NAME: JORGENSEN FORGE SITE ADDRESS: 8531 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter# Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: au,Si (3 ulldin Divlslon Public Works A/if Fire Prey ytion Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-15-13 Complete Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11-12-13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prier Friendly Page so General/Specialty Contractor A business registered as a construction contractor with Llil to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AIR SYSTEMS ENGINEERING INC UBI No. 600099211 Phone 2535729484 Status Active Address 3602 S Pine St License No. AIRSYE'229KN Suite/Apt. License Type Construction Contractor City Tacoma Effective Date 5/15/1978 State WA Expiration Date 2/1/2014 Zip 984098197 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date CRAWFORD, KANDI K President 01 /07/2010 Bond Amount COLYER, SANDRA K Secretary 01/07/2010 08358752 GEORGE, WILLIAM Vice President 01 /27/2010 CRAWFORD, DOUGLAS D Vice President 01 /07/2010 VIGILANT INS CO ANDERSON, CURTIS M 02/01/2008 01/01/1980 01 /07/2010 ANDERSON, LORINE $12,000.00 01/01/1980 01/07/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 FIDELITY Et DEPOSIT CO OF MD 08358752 02/01/2010 Until Cancelled $12,000.0001/27/2010 10/23/2012 7 VIGILANT INS CO 82138376 02/01/2008 Until Cancelled $12,000.00 02/04/2008 6 TRAVELERS CAS & SURETY CO 081S10353581BCN 02/01/2002 02/01/2008 $12,000.00 01/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 32 Travelers Property Cas Ins Co VTC2JC0828K6148TIL12 11/01/2012 11/01/2013 $2,000,000.00 10/23/2012 31 Travelers Property Cas Co of A VCT2JCO8K648YIL11 11/01/2011 11/01/2012 $2,000,000.00 10/25/2011 30 CO INGTONINS 014180670 11/01/2010 11/01/2011 $2,000,000.00 10/25/2010 28 COLEINGTON INS 049159165 11/01/2009 11/01/2010 $2,000,000.00 11/02/2009 LE27 CO INGTON INS 004052434 11/01/2008 11/01/2009 $2,000,000.00 11/06/2008 26 ACE AMERICAN INS CO 1i00G23734941 11/01/2007 11/01/2009 $2,000,000.00 10/15/2008 25 CONTINENTAL CASUALTY CO 2048527545 02/01/2007 02/01/2008 $1,000,000.00 01/16/2007 24 TRANSPORTATION INS CO TCP2048527545 02/01/2004 02/01/2008 $1,000,000.00 01/10/2007 httos://fortress.wa.gov/lni/bbip/Print.aspx • 10/25/2013 Submittal Data: System 18CL AS1118CL & AOU18CL FUJITSU Job Name: y Location: .%,r, $e .. v,r. ,e_ .Q ¢. 0: Purchaser; A t tg 'C,e t.0 r ingineer: Submitted To: For. Ail. Reference ❑I Approval D Construction Submitted By: iCnp.aeitiGS::_...... Cooling 18,000 BTU/h Min/Max Cooling 5, 500119,000BTU/h Outdoor Design Temperature PO DE/WB . 95/75 SEER 19.0 EER Low Ambient Temp. P 10.4 14 Voltage/Frequency/Phase 208-230/60/1 Indoor Unit: Noise Level db (A) - H/All U Q 44/38/32/25 Weight 20 lbs. Outdoor Unit: Noise Level db (A) 50 Recommended Fuse Size 20A Min. Ampacity 16A Running Current (Rated/Max) 7.7/9.0 Weight OUTLINE AND 'DIMENSIONS 31-W Standard Features: 88 lbs. • Six year compressor warranty Refrigerant Piping: Max Ht Difference 49 ft. Max Total or Combined Length 66 ft. Discharge Vapor Line (0.D.) 1/4 in. Suction (0.0) 1/2 in. Note: Figures are based on 230 Volts Notes: • Two year parts warranty • Refrigerant R4I0A + Auto Mode; Quiet Mode • Auto Louver: Up/Down • Apple Catechin Filter • Auto Changeover + Digital Wireless Remote Control • Sleep timet, 24 hour timer • Built in Low Ambient • Auto Restart/ Reset • Dry Mode; Coil Dry Mode • Cold Prevention • Ion Deodorizing Filter • Optional Wired Remote Control Demo Existing Air Conditioning Units. Patch With Sheet Metal Run Refrigerant Lines Exposed On Side of Building and Penetrate Into Server Room ACO -1 h Elevatio 1/8" = 1'-0" Refer Pipe 1/4" Liquid, 1/2" Suction Existing Mechanical Equipment to Remain as Found (Typical) Vie Demo Existing Wall Mounted Air Conditioning Units. Install New Ductless Split Outdoor Unit on Concrete Pad on Sidewalk Next to Existing Condensing Units With 12" • AGI -I Minimum Clearance to Wall. Run Refrigerant Piping Exposed Over Approx. 10' and Up Approx. l6' to Penetrate into Server Room. Condensate to be Routed to Adjacent Bathroom Drain. Economizer Not Required Per WEC C403.3.1 Exception I: Use of High Efficiency Cooling Equipment With SEER Values More Than 15% Higher Than Minimum Efficiencies Listedf in Tables C403.2.3. Table C403.2.3(I)A: Air Conditioners, Air Cooled <65,000 BTUH Split System Min Eff. = 13 SEER Fujitsu SEER = IQ SEER > 15% i' "gin.4 ==1 61 == Standard Features: 88 lbs. • Six year compressor warranty Refrigerant Piping: Max Ht Difference 49 ft. Max Total or Combined Length 66 ft. Discharge Vapor Line (0.D.) 1/4 in. Suction (0.0) 1/2 in. Note: Figures are based on 230 Volts Notes: • Two year parts warranty • Refrigerant R4I0A + Auto Mode; Quiet Mode • Auto Louver: Up/Down • Apple Catechin Filter • Auto Changeover + Digital Wireless Remote Control • Sleep timet, 24 hour timer • Built in Low Ambient • Auto Restart/ Reset • Dry Mode; Coil Dry Mode • Cold Prevention • Ion Deodorizing Filter • Optional Wired Remote Control Demo Existing Air Conditioning Units. Patch With Sheet Metal Run Refrigerant Lines Exposed On Side of Building and Penetrate Into Server Room ACO -1 h Elevatio 1/8" = 1'-0" Refer Pipe 1/4" Liquid, 1/2" Suction Existing Mechanical Equipment to Remain as Found (Typical) Vie 1/4" = 1'-0' Parcel Number: 000160-00 No Work in Other Buildings, Typical GENERAL NOTES 1. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.2.4.3 to Owner within 90 days of system acceptance. O&M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 1416.2.4.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air as specified in WSEC 1416.2.1 to Owner. Systems Commissioning 1. 2. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ftiO 1 E: Revisions will require a new plan submittal i and may include additional plan review fees. HVAC control system shall be tested in accordance with WSEC 1416.2.3.2. For HVAC unit, verify that thermostat activates heating mode, cooling mode, for all available stages, and verify that fan is set to run during all occupied hours. Verify initial programming of thermostat. Verify unit operation per ASEI Start and Test Report. 3. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.2.5.1 and provided to owner. 4. A Final Commissioning Report per WSEC 1416.2.5.2 shall be prepared and filed with the Owner. FILE COPY ` Permit No. Platt review approval is subject to errors and omissions. :c41. of construction documents does not orize at any adopted code or ordinance. Reipt nt approved Field Copy and is acknowledged: City Of lbkwita BUILDING DIVISI Area of Work Si� N.T.S. SEPARATE PERMIT REQUIRED FOR: � chanlcal lectrical lumbing Moe& Piping CU: -1 of Tukwila _BVI,r`NNG DIVISION e • 1an Vicon Ma \ \ \ REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1 U 2013 PERMIT CENTER MI3 1813 REVISIONS APPROVED 4L Cn rcien U) U (1) a) nob (24 ceD Tukwila, WA ti oZ U Lb AIR CONDITIONING/SHEET METAL/REFRIGERATION/PROFESSIONAL ENGINEERS/SERVICE & MAINTENANCE SHEET NO. O Demo Existing Wall Mounted Air Conditioning Units. Install New Ductless Split Outdoor Unit on Concrete Pad on Sidewalk Next to Existing Condensing Units With 12" • AGI -I Minimum Clearance to Wall. Run Refrigerant Piping Exposed Over Approx. 10' and Up Approx. l6' to Penetrate into Server Room. Condensate to be Routed to Adjacent Bathroom Drain. Economizer Not Required Per WEC C403.3.1 Exception I: Use of High Efficiency Cooling Equipment With SEER Values More Than 15% Higher Than Minimum Efficiencies Listedf in Tables C403.2.3. Table C403.2.3(I)A: Air Conditioners, Air Cooled <65,000 BTUH Split System Min Eff. = 13 SEER Fujitsu SEER = IQ SEER > 15% 1/4" = 1'-0' Parcel Number: 000160-00 No Work in Other Buildings, Typical GENERAL NOTES 1. COMPLETION As -Built Record Drawings 1. Provide record drawings with minimum information specified in WSEC 1416.2.4.3 to Owner within 90 days of system acceptance. O&M Manuals 1. Provide Operating and Maintenance Manuals with minimum information specified in WSEC 1416.2.4.2 to Owner. Systems Balancing 1. Provide a written balancing report documenting testing and balancing of air as specified in WSEC 1416.2.1 to Owner. Systems Commissioning 1. 2. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ftiO 1 E: Revisions will require a new plan submittal i and may include additional plan review fees. HVAC control system shall be tested in accordance with WSEC 1416.2.3.2. For HVAC unit, verify that thermostat activates heating mode, cooling mode, for all available stages, and verify that fan is set to run during all occupied hours. Verify initial programming of thermostat. Verify unit operation per ASEI Start and Test Report. 3. A Preliminary Commissioning Report shall be prepared, with minimum information specified in WSEC 1416.2.5.1 and provided to owner. 4. A Final Commissioning Report per WSEC 1416.2.5.2 shall be prepared and filed with the Owner. FILE COPY ` Permit No. Platt review approval is subject to errors and omissions. :c41. of construction documents does not orize at any adopted code or ordinance. Reipt nt approved Field Copy and is acknowledged: City Of lbkwita BUILDING DIVISI Area of Work Si� N.T.S. SEPARATE PERMIT REQUIRED FOR: � chanlcal lectrical lumbing Moe& Piping CU: -1 of Tukwila _BVI,r`NNG DIVISION e • 1an Vicon Ma \ \ \ REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1 U 2013 PERMIT CENTER MI3 1813 REVISIONS APPROVED 4L Cn rcien U) U (1) a) nob (24 ceD Tukwila, WA ti oZ U Lb AIR CONDITIONING/SHEET METAL/REFRIGERATION/PROFESSIONAL ENGINEERS/SERVICE & MAINTENANCE SHEET NO. O