HomeMy WebLinkAboutPermit M13-191 - COSCO FIRE PROTECTION - ALTERATIONCOSCO FIRE PROTECTION 4310 S 131 PL M13-191 City oiirukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7349200135 Address: 4310 S 131 PL TUKW Project Name: COSCO FIRE PROTECTION Permit Number: M13-191 Issue Date: 10/29/2013 Permit Expires On: 04/27/2014 Owner: Name: NORMED SHAW PTN Address: PO BOX 3644 , SEATTLE WA 98124 Contact Person: Name: ALEX BURIKHART Address: 727 KENYON ST , SEATTLE WA 98108 Email: Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE, WA 98108 Contractor License No: EVERGRL954R2 Phone: 206-763-1744 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: Value of Mechanical: $4,045.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $249.00 International Mechanical Code Edition: 2012 (,) Date: [0- 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: tSvv'1.J-- Date: La This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. RA11_101 Printers• 1n -79-7n11 • • PERMIT CONDITIONS Permit No. M13-191 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rInn• IMC -4/10 M13-191 Printed: 10-29-2013 CITY OF TUKWI• Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 13q 61160 13 S Site Address: 14 31 t 5, Tenant Name: CDSLa Fire- Prefe-cri-a>h Suite Number: Floor: New Tenant: ❑ Yes PROPERTY OWNER Name: prit'. ti of Name: ND�fr,,,,a 5hmt, pp 1 1� City: ,610./(k1/4. State: vb. Zip: Ill o Address!: 12_0 4 x 36‘,14 Email: au:13 e e.,,,,,rivet, 6,0,,c_,1401 City: Se, iw State: Zip: c� $ Zy CONTACT PERSON - person receiving all project communication Name: prit'. ti of Address: -i /L i s0,A.4„.1 v ,t,h s1t.--. City: ,610./(k1/4. State: vb. Zip: Ill o Phone: • t6— 7(3— 1- q j Fax: --/DG- 1L3— V5 s,1 Email: au:13 e e.,,,,,rivet, 6,0,,c_,1401 ..No MECHANICAL CONTRACTORINFORMATION Company Name: a vere rc¢,h I4 ,y.„4 L- L -i Address: 71.-1 50,441I,ceit©t't s --_ City: 5 tuktit State: 1W p Zip: etV08 Phone: 1 6 - .x 3 - i...N i Fax: 2A G _143 - 73 rd et Contr Reg No.: etz. ' Lq S4ttlxp Date: I 1 6 `0 Tukwila Business License No.: t.vs _Octet 21.7.-1 Valuation of project (contractor's bid price): $ �1 o�s.61) Describe the scope of work in detail: 1v)ti.1 't 1 c a� (c”) d kg1+-45 5p (A- s tS%m A/L Use: Residential: New ❑ Commercial: New Replacement Replacement Fuel Type: Electric Er Gas ❑ CI CI (Jig k Other: H:Wpplications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 1 / kc, ! 3 Print Name: 4. Bw14,11'ar*- Mailing Address: ?>( ✓ A't tov1 $`\SedAkle- /Aft Day Telephone: E — 1114 14 H:\Applications\Forms-Applications On Line 1201 I Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh City State Zip Page 2 of 2 wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200135 Address: 4310 S 131 PL TUKW Suite No: Applicant: COSCO FIRE PROTECTION RECEIPT Permit Number: M13-191 Status: PENDING Applied Date: 10/16/2013 Issue Date: Receipt No.: R13-02894 Initials: User ID: JEM 1165 Payment Amount: $249.00 Payment Date: 10/16/2013 01:00 PM Balance: $0.00 Payee: EVERGREEN REFRIGERATION, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 006155 249.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 199.20 000.345.830 49.80 Total: $249.00 orinrorl• 1n_1 a_9n1'2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit. Inspection Request Line (206) 431-2451 � t 13 -►4 l Pr ect: ` Type Inspection: Address: 1-13 l D l s' 9( Date Called: Special Instructions: Date Wanted: I I I i_-. (I a.m.. :m: Requester: Phone 2c)(o-(ei-7c(11 e-r(Pyevri; lir-kJ — 4-Pfa ilo t.AApproved per applicable codes. Corrections required prior to approval. COMMENTS: -1)%0t._ I_NAuI. -ApP/iik/Pc R..7116114 --/N/ - rl * IA✓P(1 e-r(Pyevri; lir-kJ — 4-Pfa ilo r *ILL? if % , t -i.— / „.---../ --,,,_ . _ Date: /t„ 3 GiAZA-Al n EI SPECTION FEE RE UIRED. Prior to next inspection. fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM nerCode Comliance Forms for Commercial, Group R1, and > 3 story R2 and R3 gy p Revised June 2013 Project Info Project Address 4130 S 131st Pl. Date 6/3/2013 Tukwila, WA 98168 For Building Dept. Use Applicant Name: Alex Burkhart Applicant Address: 727 South Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Briefly describe system type Description mechanical and features. Plans Installation of one (1) ductless split system AC unit. FILE COPY Drawings must corpertes'?enir g comptimeesivitfretTIMMelffrIlrprovisions per Section C408 si Includes Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception' Heat Recovery Y/N AHG -1 / 03-1 Mitsubishi MSY-G809NA-8 / MGT - 6S09NA 9000 N/A 21 N/A C403.3.1. N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM Sp' HP/BHP Flow Controls Location of Service Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Input Capacity Sub- Category EF' CC �� LocEi9Rbfr@rvie.:e'-' en Y OF TUKVVILA REVIEWED FOR CODE COMPLIANCE OCT 1 5 2013 APPROVED „�,, ,. .. .. 4, ocDvrr ('rnI-rrl ' If avaTat61e. sLest�ed acco r.i ng to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. ^ COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 6 Flow control types: ariable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per City of Tukwila BUILDING DIVISION Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 4130 S 131st PI. Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance YesChapter C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per 3 M1 Yessizing C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M 1 Yesventilation C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical is capable of being reduced to minimum requirement per IMC . M1 Yes C403.2.3 & C403.2.3.2 &capacity, C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, efficiency, test standard (or other efficiency source) for all mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. N/A 0403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/Achillers C403.2.1 Non-standard water-cooled Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A 0403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss N/A C403.2.3.3 heatinq/coolinq equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria Yesperimeter C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including systems M1 Yes 0403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp M1 Yescooling C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & M1 Yes 0403.2.4.3 Automatic setback and shutdown Indicate zone t -stat controls with required automatic setback & manual override M1 Yesconditions C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load M1 Yes C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M 1 Yes C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M1 N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating i equpment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Yes 0403.2.5.1 ventilation Demand controlled Indicate high -occupancy spaces and systems requiring DCV M1 Yesalternate C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or means provided to automatically reduce OSA when partially M 1 Yes C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method M1 N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) N/A 0403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on-site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy recovery - condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH;-CHK Revised June 2013 Project Address 4130 S 131st Pl. Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHI( pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) C403.2.12.1 VarN/A cooling towers flow control - cooling Indicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N A / C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adiustment Ducting Systems Yes C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements 1 N/A 403.2.7.3.1 ; Duct pressure Identify location of low, medium and high pressure ductwork on plans N/A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R -value of insulation on ductwork M l Piping Systems N/A C403.2.8 Piping insulation Indicate R -value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems Yes C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling Ml N/A C403.3 Qualifying 2 -pipe heating systems Verify 2 -pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M l Yes C403.3.1.1.3 controls Air economizer high limit Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M l Yes C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh 1 Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) M 1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. 1 Yes C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation Ml Yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems �1 N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) Mechanical Permit Plans Checklist - Pa,a e 3 of 3 MECH-CHK Revised June 2013 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Project Address 4130 S 131st PI. Date 6/3/2013 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A 0403.4.2 & c403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A 0403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/Asetpoint C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving mufti- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N A /loads C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to N/A 0403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 systems Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/Aisolation C403.4.3.5 Chiller / boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method N/A 0404 & C403.4.4 Variable flow control - cooling towers Indicate cooling tower fans requiring variable flow control and method N/A 0403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by t 50% for systems > 300,000 N/A 0403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/Adeadband C403 4 3 3 1 Water loop heat pump - Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat resection and heat addition modes N/A 0403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A 0403.4.3.3.3 Water loop heat pump - isolation Indicate 2 -way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A 0403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A 0403.5 / 6 Cooler / freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Wa er Systems N/A 0404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N A /discharge C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & N/A 0404.5 water Insuheater Indicateunder Indicate R-10 insulation under tank N/A 0404.6 Service water piping insulation Indicate R -value of insulation on piping; note exceptions taken N/A 0404.7 / g Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters >_ 4 COP N/A 0404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A 0404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-191 DATE: 10-16-13 PROJECT NAME: COSCO FIRE PROTECTION SITE ADDRESS: 4310 S 131 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: uirding ivislon Public Works WW1 OK lig" Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-17-13 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: 1)4 REVIEWER'S INITIALS: DATE: DUE DATE: 11-14-13 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prier Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LW to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING Et ENGY Construction Contractor General Unused 4/20/2009 4/20/2015 Active EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Archived Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner/Member 12/22/2005 Bond Amount PATTON, DAVID Partner/Member 01/06/2006 WA15097 PATTON, RODGER Partner/Member 01 /06/2006 PATTON, MATTHEW Partner/Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/15/2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2014 $1,000,000.00 07/30/2013 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.00 03/23/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa. aov/lni/bbip/Print.aspx 10/29/2013 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 252013 r City of Tukwila BUILDING DIVISION VICINITY MAP SCALE : NONE COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION C408.1.3 AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION C408.1.3.2 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION C408.1.3.3 MECHANICAL EQUIPMENT AND CONTROLS SHALL COMPLY WITH WSEC SEC. C408.2 FOR ALL SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION C408.2.3 A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION C408.1.2 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION C408.1 SPLIT SYSTEM EQUIPMENT SCHEDULE MARK MANF. MODEL COOLING ELECTRICAL WEIGHT NOTES MIN CAPACITY SEER TOTAL INPUT VOLTS PHASE M.C.A. BTUH W (V) (A) LBS AHU -1 MITSUBISHI ELECTRIC MSY-GEO9NA-8 --- 115 10 1 22 STAT @ AHU CU -1 MITSUBISHI ELECTRIC MUY-GEO9NA 9,000 21.0 660 208-230 10 12 66 144' GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH .. . DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS. THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. . 3.9. GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INS?"ALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL: CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 . ERL TO PRCVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL. CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT. OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC ;;EC. C402.4.5.2 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY,CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. C403.3.1 MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2013 60' HVAC SECOND FLOOR PLAN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT r. QUIRED FOR: 0 MdchanIcal ErElectrical Iumbing as Piping City of Tukwila BUILDING DIVISION FILE COPY Permit Na. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize thE. violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: fir' Data: 1A I City Of 1Ukwlla BUILDING DIVISION i RECEIVED CITY OF TUKWILA OCT 152313 PERMIT CENTER 1;•--1 1, I EVERGRL954R2 NOT PUBLISHED. ALL. RIGHTS RESERVED. THE . DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE-' RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS CR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS, . • DESIGN DEVELOPMENT DATE: 10/10/13 • ISSUED FOR CONSTRUCTION DATE: 10/14/13 ❑ AS BUILT DRAWINGS DATE: COSCO FIRE PROTECTION HVAC COVER SHEET 4310 S 131ST PLACE TUKWILA, WA 98168 REVISIONS NO DATE ITEM DWG. BY: .GN CHK. BY: CS/MG JOB NO.: 513465 SHEET: M 1