Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-197 - BOEING #9-101 - ADC HVAC UPGRADE ALTERATION
BOEING #9-101 ADC HVAC UPGRADE 9725 E MARGINAL WAY S M13-197 iTh City of Tukwila Department of Community Development 2v 6300 Southcenter Boulevard, Suite #100 � Tukwila, Washington 98188 i8 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: 0003400018 MECHANICAL PERMIT 9725 EAST MARGINAL WAY S Project Name: BOEING #9-101 - ADC HVAC UPGRA Permit Number: M13-197 Issue Date: 4/10/2014 Permit Expires On: 10/7/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PROPERTY TAX DEPT PO BOX 3707 M/C 20-00, SEATTLE WA, , 98124 CONNIE HARDIN 4600 S 134 PL , TUKWILA WA, , 98168 HOLADAY PARKS, INC. PO BOX 69208 , SEATTLE, WA, 98188 HOLADP1379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2015 DESCRIPTION OF WORK: SUBTYPE: NRES STATUS: PENDING DESCRIPTION: REPLACE EXISTING AIR HANDLING UNIT AND ASSOCIATED DUCT WORK WITH NEW AIR HANDLING UNIT AND DUCT WORK AND DIFFUSERS. INCLUDES NEW HOT WATER AND CHILLED WATER PIPING. Valuation of Work: $220,000.00 Type of Work: Fuel type: Fees Collected: $2,624.62 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: L1H lb • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws r-:ulating construction or the performance of work. I am authorized to sign and obtain this develop i' ind gre to the conditions attached to this permit. Signature: -- Print Name: �(j c\,(1, e `111. isd c Date:q_t �./� ` This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 3: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any.questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 14: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approyal will be determined by the building inspector based on satisfactory completion of this requirement. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. • M 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 18: ***MECHANICAL PERMIT CONDITIONS*** 19: All mechanical work shall be inspected and approved under Tukwila Permit Center (206/431-3670). 20: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST a separate permit issued by the City of the job site at the time of inspection. CITY OF TUKW` Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** .._. A _.. / n in g ssessor's Tax No.: OQ J `f ( / Site Address: 97(72,S -- f Pa Lin ) /a// ' L,Wee y' c° Co3Suite Number: Floor: Tenant Name: PRO _ 4 -Viet -C__ 0 P E •-- f , . New Tenant: ❑ Yes No Name: Q N E�Oe�. �C,✓r Address;, State: i f Zipco 2 Name:% 1�1�Vll `isIAC i(n Address: 1/67a.) /30/71. City State. Zip:%(/ Phone: te, � G,sn/ Fax: ziev;5, Z , - 7d Email: Company Name: b, _Cr3eXic"-- Address: 46700 600 s 4cti-k City: ft - State: , '7 Zip . Addr• es r l �0 Fax: 7 )% % `( /6,6 Contr Reg POL44- � �4 n-,OExp Date:,_ >/ Tukwila Business License No.: Valuation of project (contractor's bid price): $ Zz D, 0 a 0 Describe the scope of work in detail: .6)05 77,41.- ,4/1 / , , —SSOC, '1 v,,r7e,-ee t- 77i Asf"S✓ 4/-1(/ Dt/C., tv erects/iFv ti77 r % G` ��fJ /051-17 h' / i/ •f CPA, /e7/791',0'6-- Use: e7ir9rs0'6- Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement , Fuel Type: Electric ❑ Gas ❑ Other:1--/or h- — C /z4.6 H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 hh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace (.100k btu Furnace>100k btu / 0 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm / Unit Type Qty Air handling unit >10,000 cfm / 0 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser / 0 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/ 100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI Signature:Date: Print Name: Mailing Address [ S 1?,4 P Q Q_ Oac_ Qi(UV Day Telephone: In Z57) Q'J T 2 H:Wpplications\Forms-Applications On Line 12011 Applications\Mechanical Permit Application Revised 8-9-1l.docx Revised: August 2011 bh City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $292.50 M13-197 Address: 9725 EAST MARGINAL WAY S Apn: 0003400018 $292.50' DEVELOPMENT $292.50 PERMIT REINSPECTION FEE TOTAL FEES PAID BY RECEIPT: R2257 R000.322.800.00.00 0.00 $292.50 $292.50 Date Paid: Tuesday, June 03, 2014 Paid By: HOLADAY PARKS, INC. Pay Method: CREDIT CARD 02213G Printed: Tuesday, June 03, 2014 9:37 AM 1 of 1 CJI1WSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,099.70 M13-197 Address: 9725 EAST MARGINAL WAYS Apn: 0003400018 $2,099.70 Permit Fee Permit Fee TOTAL FEES PAID BY RECEIPT: R1772 R000.322.100.00.00 $2,099.70 $2,099.70 $2,099.70 Date Paid: Thursday, April 10, 2014 Paid By: HOLADAY PARKS FAB INC Pay Method: CREDIT CARD 06588G Printed: Thursday, April 10, 2014 3:22 PM 1 of 1 CSYSTEMS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M13-197 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 10/29/2013 Applicant: BOEING #9-101 Issue Date: Receipt No.: R13-03002 Payment Amount: $524.92 Initials: BLH Payment Date: 10/29/2013 01:12 PM User ID: ADMIN Balance: $2,099.70 Payee: HOLADAY PARKS - CONNIE HARDIN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04046g ACCOUNT ITEM LIST: Description 524.92 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 524.92 Total: $524.92 'Inr• Rcrcin4_r1R Printed: 10-29-2013 J)0 INSPECTION RECORD Retain a copy with permit A7)13-17) INSPECTION NO. PERMIT NO. .. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Projec : oe,n HO, Type of Inspectio ac. NAL,, Addre s: ...-- (17.1 °1 i,4) c \ l 4x6.1 air Date Called: ..—, Special Instructions: r 4' tj J! Date Wanted: j (j)'30 Jf-+ / a`.m�„ p.m. Requester: v 27. Approved per applicable codes. Corrections required prior to approval. COMMENTS: PrM 6-40/(1)( ,4 Inspector: Date: ea 17 r 4 f REINSPECTION FE 'REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0:. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: t - CD(PJC� 10( Type of Inspection: nnzlkP S E Address:0-72-5 Ac.>" . A(CEN1C- d: Special Instructions: Date,Wanted: 617 --- "I — l /-( /aim- Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: A/P/1"/ ' (7 -T-4(4,, ,ai� Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be pad;at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. y', Date: _ //,_ ri INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: , ex c50Q._cnn i-Jqs \ Typp.,of Inspection: N.63 Gid 2ri Address: t, Date Called: Spe ial Instructions: f % I 0,5kiL Alt Date Wanted:5 — (c.3 — q 1 P.m. Requester: Phone No: Approved per applicable codes. LjCorrectlons required prior to approval. COMMENTS: Inspector Date:5 (t) 1<-): 1-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain; a copy with permit INSPECTION_ NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43-3670 Permit Inspection Request Line (206) 431-2451 Prkov&M o e6t: / 7_,0, Type of ins c i n: —._1A1 A ress: ci 7Z ,,, E /s, -s21 /Na Date Called: Special Instructions: Date e --W me • 0 /j / �- '"7 a.m.1 4, p.m.' Requester:. , Phone No: 62`.0 „02-0. O 9 3/ pproved perapplicable codes. Lj Corrections required prior to approval. COMMENTS: Inspector: Date:1/ r n REINSPECTION FEE REQOIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit -nri-I3-147 - - ciS PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:�l iSoe ir) Date: , ,/if / / t( Sprinklers: Type of Inspection: PI-e Address:o Suite #: `o S �,,` y S Contact Person: Special Instructions: Permits: Phone No.: f4pproved per applicable codes. Corrections required prior to approval. COMMENTS: Date: , ,/if / / t( Sprinklers: f& no r S N SfQe i`ib►1/. I1ood &. Duct: Monitor: \ Pre -Fire: Permits: Occupancy Type: — < .--c OAC s (4- ` ov vv. -- 0.,e Needs Shift Inspection: Date: , ,/if / / t( Sprinklers: Fire Alarm: I1ood &. Duct: Monitor: \ Pre -Fire: Permits: Occupancy Type: Inspector: p 5,_ Date: , ,/if / / t( Hrs.: ii m, rJ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 NEUDORFER ENGINEERS INC. TEST, ADJUST & BALANCE BALANCE REPORT Boeing Building 9-101 ADC -3 Seattle, Washington 2014-205 Project Completion Date: 05/29/14 Revision Date: Revision Number: 5516 1" Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 1 19� RECEIVED CITY OF TUKWILA JUN 3 0 2014 PERMIT CENTER 2501 SE Columbia Way, Ste. #230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 PROJECT LOCATION Boeing Building 9-101 / ADC -3 Seattle, WA TABLE OF CONTENTS Cover Report Title 3 Certification 4 Warranty 5 Terms & Abbreviations 6-7 Executive Summary 8 Supply Air 9-10 TAB Drawings 11-13 Instrument Calibration 14 Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Report Title CERTIFIED TEST: BALANCE REPORT Project: Boeing Building 9-101 ADC -3 Seattle, Washington NEI Job#: 2014-205 Engineer: Sazan group Contractor: Holaday Parks TAB Firm: Neudorfer Engineers Inc 5516 1st Avenue South Seattle, WA 98108 Test Engineer: Casey Riggle Architect: -- 5516 1st Ave S Seattle, WA 98108 Phone (206) 621-1810 Fax (206) 343-9820 et Engin WILLIAM C. NEUDORFER CERTIFICATION 2465 \ Etp3 1/15 2501 SE Columbia Way, Ste. #230 Vancouver, WA 98661 Phone (503) 235-8924 Fax (503) 235-8925 Neudorfer Engineers. Inc. Consulting Engineers Soattle Portland CERTIFICATION Boeing Building 9-101 The data presented in this report is a record of system measurements and final adjustments that have been obtained in accordance with the current edition of the NEBB Procedural 'Standards for Testing, Adjusting, and Balancing of Environmental Systems. Any variances from design quantities, which exceed NEBB tolerances, are noted in the Test-Adiust-Balance Report Proiect Summary. Significant / Noteworthy Remarks are noted on the General Remarks and General Field Notes pages. Other remarks are noted on individual test sheets. Noted deficiencies are not Neudorfer Engineers responsibility to repair. Prior to issuance of this report, Deficiency Reports are forwarded to our contracted agent. Warranty is limited to one year from date of this report. Within that time, any discrepancies, ambiguities, or omissions found in this report will be retested, adjusted, or balanced as needed. A written notification will be required. Submitted and Certified by: NEBB TAB Firm: Neudorfer Engineers Inc Certification No: 2465 Expiration Date: March 31, 2015 Certification Date: May 29, 2014 (Date completed) Signed and Sealed by: NEBB Supervisor: William C. Neudorfer WIWAM C. NEUDOAFEA CERTIFICATION \2465 Exp. wav15 , Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Warranty Project: Boeing Building 9-101 Warranty of Services: Neudorfer Engineers, Inc. warrants that the air & hydronic balancing, evaluated during this performance evaluation are operating at the specified levels as documented within this report. At and only this time, and makes no other warranties, stated or implied, concerning the continued performance,operation or safety in the use of this equipment past this time. Neudorfer Engineers warrants the air and hydronic balancing for 1 year from the date of substantial completion. Neudorfer Engineers reserves the right to correct errors or omissions in the collections of data. Warranty,Procedures: For all warranty items, Neudorfer Engineers requires written request. The written request should be specific on the areas of concem, such rooms, or equipment, and the type of issue the occupants are having. Once written notification is received Neudorfer Engineers will schedule a Technician. It is recommended that and Owner or A/E Representative be on site at that time. Voided Warranty and Additional Charges: If a complaint issue is due to a mechanical equipment failure, control or maintenance related, the return trip maybe subject to a service charge, not covered under warranty. Neudorfer Engineers reserves the right to resolve any TAB issue. If a third party or competing Test & Balance/ Commissioning firm test or adjust any equipment, all project warranty is voided. (This is typical standard for the Mechanical industry, as Manufacture, Mechanical and Control Contractor voids all warranty when a competing firm test or manipulates their systems.) Any return trip to the job site are subject to a service charge and a purchase order will be required before returning to the job site. Document Archiving An electric file of all test documents will be kept on file until the end of the Warranty period. During that time and electronic copy of the test data will be provided a no charge. Any additional hard / bound copies requested will be subject to a fee. Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland www NeuoorterEngin fr."`:.co Terms and Abbreviations Project: Boeing Building 9-101 AC or ACU Act. ACCO Address AH or AHU Amps AP APP. Arr AVG BHP BTU BTUH CAV CBV CC CD CFLA CFM CH CHWS CHWR Coeff. CP CR CRAC CRU CT CU CUH CWS CWR DAT DB DD DDC Delta Air Conditioner or Air Conditioning Unit Actual Air Cooled Condensing Unit Equipment designation number given on the Control Program Air Handler or Air Handling Unit Amperage Access Point Application Arrangement Average Brake Horsepower British Thermal Units British Thermal Units per Hour Constant Air Volume Calbirated Balancing Valve (Circuit Setter) Cooling Coil Ceiling Diffuser Correct Full Load Amperage Cubic Feet per Minute Chiller Chilled Water Supply Chilled Water Return Coefficient Circulating Pump Ceiling Register Computer Room Air Conditioner Computer Room Unit Cooling Tower Condenser Unit Cabinet Unit Heater Condenser Water Supply Condenser Water Return Discharge Air Temperature Dry Bulb Direct Drive Direct Digital Controls: EMS Control System for the HVAC Difference, net decrease or increase Des. Dia. Disch. DNL EA EAT Economizer EDC EDH EF EG EMCS ERU E.S.P. Evap. EWT FCU FD FH FLA Flow Hood FPB FPM FR FT FTU GPM HC HD Design Diameter Discharge Data Not Listed Exhaust Air Entering Air Temperature Controls and components that allow an air handler to logically utilize outdoor air for cooling as opposed to the use of mechanical cooling. Electric Duct Coil Electric Duct Heater Exhaust Fan Exhaust Grille Energy Management Control System Energy Recovery Unit External Static Pressure Evaporator Entering Water Temperature Fan Coil Unit Fire Damper Fume Hood Full Load Amperage: Maximum amperage a motor can draw. Instrument that captures air and converts the reading to CFM. Fan Powered Box Feet per Minute Field Report Foot, Feet Fan Terminal Unit Gallons per Minute Heating Coil Pressure Difference across the entering and leaving side of a pump. Heater O.L. Thermal overload protection for motors located at the motor starter (starter heaters) HEPA High Efficiency Particulate Arrestance HOA Hand / Off / Auto Switch HP Horsepower Neudorfer Engineers. Inc. Consulting Engineers Seattle Portland Terms and Abbreviations Project: Boeing Building 9-101 HRC Heat Recovery Coil HUH Hydronic Unit Heater HVAC Heating Ventilation andAirConditioning HWS Heating Water Supply HWR Heating Water Retum HX Heat Exchanger HZ Hertz, cycle per second I.D. Inside Diameter in. inches in.w.g. inches of water gauge Kfactor Correction factor to the free area need to calculate CFM. KW Kilowatts LAT Leaving Air Temperature LWG Low Wall Grille LWR Low Wall Register LWT Leaving Water Temperature MAU Make-up Air Rangling Unit MBH 1,000 BTUH MAX. Maximum Flow Requirements for DDC MBH Mega BTUs per hour (1MBH=1,000BTUH) MIN Minimum Flow Requirements for DDC N/A Not Available N/S Not Shown or Specified OA Outside Air OBD Opposed Blade Damper O.D. Outside Diameter PD Pressure Drop. PH Phase PHC Preheat Coil Prim. Primary PSI Pounds per Square Inch RA Retum Air RAT Retum Air Temperature RF Retum Fan RH Relative Humidity RHC Reheat Coil RPM Revolutions per Minute RTU Roof Top Unit RVA Rotating Vane Anemometer -reads air velocity in feet per minute SA Supply Air SAT Supply Air Temperature S.F. Service Factor Schedule Design data obtained from the (sched) mechanical prints' schedule of equipment. SCR Silcon Controlled Rectifier Speed Controller SF Supply Fan SFD Smoke/Fire Damper SP Static Pressure Spec(s) Specifications sq.ft. square feet Submittals Submitted data on equipment (subs) capabilities. Suct. Suction SWG Sidewall Grille SWR Sidewall Register TAB Test; Adjust; and Balance Tach Tachometer Tech Technician TSP Total Static Pressure: Difference between the entering and leaving static pressure of a fan. TP Traverse or Test Point UH Unit Heater VAV Variable Air Volume; box that contains a motorized damper that modulates airflow. VD Volume Damper VFD Variable Frequency Drive Velgrid Instrument that reads used to read velocity in feet per minute. VP Velocity Pressure VVT Variable Volume Terminal WC Water Column W.G. Water Gauge WB Wet Bulb l Veudor er Engineers. Inc. Consulting Engineers Seattle/ Portland PROJECT Boeing Building 9-101 ADC -3 LOCATION Seattle, WA EXECUTIVE SUMMARY This project has been balanced per plans and specifications, unless otherwise noted. Each system has been balanced using the National Environmental Balancing Bureau (NEBB) standards and procedures. The equipment has been checked for correct operating data which includes: operating amperage, voltage, rotation, RPM, CFM (cubic feet per minute), and operating static pressures, unless otherwise noted in the final Balancing Report. Please see attached TAB drawings for individual inlet and outlet numbering. AIR SYSTEM AH2N13 - Has a design supply airflow of 5,000 CFM and is currently delivering 4,930 CFM, 99% of design airflow. It has a design return airflow of 4,440 CFM and is currently returning 4,125 CFM, 93% of design airflow. The outside airflow station was calibrated with the unit postured in 100% outside air. Once the outside airflow station was calibrated, a minimum outside air damper position was established at 29% delivering 575 CFM of outside air, 103% of design outside airflow. The design schedule minimum outside air is listed at 560 CFM. NATIONAL ENVIRONMENTAL BALANCING BUREAU 1r� Neudorfer Engineers. Inc. ,. Consulting Engineers Seattle Portland Air Handling Unit PROJECT: Boeing BLDG 9-101 ADC -3 LOCATION: , WA PROJECT #: 2014-205 DATE: 6/20/2014 CONTACT: Casey Riggle SYSTEM/UNIT: AH -2N13 AREA: Unit Data Unit Manufacturer Energy Labs Unit Model Number C5456-FCH-E Unit Serial Number 1312-7472-AH2N13 Unit Discharge Horizontal Fan Rotation Correct AH -2N13 / SF Filter Bank 'Filter Manufacturer Flanders Filter Type Pleated Filter Quantity - Size 1 4 Filter Dimensions - Size 1 24x24x2 Filter Quantity - Size 2 4 Filter Dimensions - Size 2 24x24x12 Starter Data AH -2N13 / Return Fan Starter Manufacturer Danfoss Starter Model, No. VFD AH -2N13 / Supply Fan Starter Manufacturer Danfoss Starter Model No. VFD Test Data Total Design Flow 5000 CFM Total Actual Flow 4930 CFM OA Design Flow 560 CFM OA Actual Flow 575 CFM RA Design Flow 4440 CFM RA Actual Flow 4125 CFM AH -2N13 / Return Fan Fan RPM Actual 1785 RPM Motor RPM Actual 1785 RPM VFD Setting 60 Hz Motor Volts T1-T2 457.3 Volts Motor Volts T2-T3 457.3 Volts Motor Volts T1-T3 457.3 Volts Motor Amps T1 3.89 Amps Motor Amps T2 3.89 Amps Motor Amps T3 3.89 Amps AH -2N13 / Supply Fan Fan RPM Actual 1793 RPM Motor RPM Actual 1793 RPM VFD Setting 60 Hz Motor Volts T1-T2 455.7 Volts Motor Volts T2-T3 455.7 Volts Motor Volts T1-T3 455.7 Volts Motor Amps T1 4.88 Amps Motor Amps T2 4.88 Amps Motor Amps T3 4.88 Amps Tested By: Casey Riggle Test Date: June 20, 2014 Motor Data AH -2N13 / Return Fan Motor Manufacturer Baldor Drive Type Direct Drive Motor Frame 184T Motor HP 5 HP Motor RPM 1750 RPM Motor Rated Volts 208-230/460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 14 - 13.2 / 6.6 Amps Motor Service Factor 1.15 Motor Efficiency 0.895 % Motor Power Factor 0.79 PF AH -2N13 / Supply Fan Motor Manufacturer Baldor Drive Type Direct Drive Motor Frame 213T Motor HP 7 1/2 HP Motor RPM 1770 RPM Motor Rated Volts 230/460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 19 / 9.5 Amps Motor Service Factor 1.15 Motor Efficiency 0.917 % Motor Power Factor 0.81 PF Test Pressures Pre -Filter Inlet SP -0.14 in. wc Pre -Filter Outlet SP -0.20 in. wc Final Filter Inlet SP -0.20 in. wc Final Filter Outlet SP -0.55 in. wc Clg Coil Inlet SP -0.55 in. wc Clg Coli Outlet SP -0.60 in. wc Htg Coil Inlet SP -0.60 in. wc Htg Coil Outlet SP -0.69 in. wc SF Suction SP -0.69 in. wc SF Discharge SP 0.32 in. wc SF Actual Total SP 1.01 in. we RF Suction SP -0.55 in. wc RF Discharge SP 0.70 in. wc RF Actual Total SP 1.25 in. wc OA Damper Pos 29 % RA Damper Pos 71 % Neudorfer Engineers= Inc. 1 Consulting Enginaors Seattla Poritand voe Air Handling Unit PROJECT: Boeing BLDG 9-101 ADC -3 LOCATION: , WA PROJECT #: 2014-205 DATE: 6/20/2014 CONTACT: Casey Riggle SYSTEM/UNIT: AH -2N13 (Cont.) AREA: AH -2N13 Supply Outlet Summary Tested By: Casey Riggle Test Date: June 20, 2014 System / Unit Type of Reading Outlet Type Size LXW / D AK Design Velocity Design Value Prelim Reading Final Reading Final % Remarks Outlet -01 Flowhood CD -1 12"x12" 1 - 590 430 570 97 (1),(2) Outlet -02 Flowhood CD -1 12"x12" 1 - 590 465 565 96 Outlet -03 * Flowhood CD -1 12"x12" 1 - 590 340 535 91 (1) Outlet -04 Flowhood CD -1 12"x12" 1 - 590 490 565 96 - Outlet -05 Flowhood CD -1 12"x12" 1 - 400 550 410 103' Outlet -06 Flowhood CD -1 12"x12" 1 - 400 285 395 99 Outlet -07 Flowhood CD -1 12"x12" 1 - 400 445 430 108 Outlet -08 Flowhood CD -1 12"x12" 1 - 400 345 400 100 Outlet -09 Flowhood CD -1 12"x12" 1 - 520 80 520 100 Outlet -10 Flowhood CD -1 12"x12" 1 - 520 640 540 104 Totals : - - - -- 5,000 4,070 4,930 99 % - AH -2N13 Return Inlet Summary System / Unit Type of Reading Outlet Type Size LxW / D AK Design Velocit Design Value Prelim Readin Final Reading Final % Remarks Inlet -01 * Flowhood RAG 485(24" 1 - 2200 1375 2035 93 (1),(2) Inlet -02 Flowhood RG=1 18"x18" 1 - 1400 1320 ' 1310 94 Inlet -03 Flowhood RG -1 18"x18" 1 - 840 1390 780 93 Totals : - - - - - 4,440 4,085 4,125 93 % - * Notes AH -2N13 2 -Jun -14 Casey Riggle Operating amps and volts were recorded from the VFD. AH -2N13 2 -Jun -14 Casey Riggle The outside air flow station was calibrated with the unit postured in 100% outside air. AH -2N13 / Inlet -01 29 -May -14 Casey Riggle (1) The volume damper is full open. AH -2N13 / Inlet -01 29 -May -14 Casey Riggle (2) The inlet was read with the flowhood, the inlet was back pressure compensated due to the volume of airflow. AH -2N13 / Outlet -03 29 -May -14 Casey Riggle (1) The volume damper is full open. AIR HANDLING UNITS 51557457 5SA 9Hm {W 8010 015 WOW MSm. M 5706 in F.0 10 lei. Ca Tao SF 11 1420 756 571 /5PN bV W 05 , �1 . •.: 'Iii.. -L 451 :1 1.11. a. •. • 1 a •• -.. •. n W OY 0. k ' 708 05 u'r 4£11 YUl 573 110.53 Yd R. 2� .SM WIjP 2. . kl 1114 iNL191 R MRl @W 41 a 3300. 50 113 IOC (57M 3200 3.5 19 1040 2 1341 403/3 0A 73 SAW W 5 54] 514 2.0 42 50 141 )R 10 111 0 G 58 011 11 100loo 47 21000 45 21.1 154 10 110 IR 2 10.17 5 rue 214 572 795 1.00 54111 IFA 'I 14 t Q00 RE-1102 40 57 r00 M I.1.3AA41pp 5 011) IAC B01£11.0401£11.041/12005120 5.000R5.0004 0 I0 S 1 1012 40/3 u 210 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1.02050 N0TES: • I. 006C7 6M PPM 156 : 5A IaoMWA B! 006 0. MT. Pm O2U00. 2' 9610 a9.0To1 ER RE. 0410333 11072.3 S 511 03000111 La 3021 7. maw. R. 5757F11169.304 M. WW1Ml B u 54015 t 15114 COMM. 0 W6 11601177. 130 IBA CUR MOW 001-10-5 fi 50014401 SILL2! COMM /MEl •• 454 - SRIR 801 15701451 2512 W R 57 580 341115. IF17W815W00 5 01 060857 17511a M170. 50 5023 5215111 MEOW Mat. la Fan Mau. I. 2.71155 5811 0-042.85051 • EQUIPMENT S.UNI POWER LEVEL SCHEDUL ml. 34 m 425r2,341:1113....10 4/14 —....;:,:.c:.■. ,50 �_ ..a 11:1.:1102,a..:. X111.15.....11.4......./041.33,1 4 ®1.11..11111211..11 1.1.11•111511.1131.5. 17tP.:4•.1015 1:11..1111.111.11.11..1�.1B:S�:\B!.':. X14 10250 LEGENQ GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES D% ROM Ip 5017 4 00126 D> MU io 00223 50 657916 4 SAZAN GROUP B/8 82.5181.. .1400 bumf. Waste. 24101 ®T5 0029.17/8 Fa 00281.1151 11.../AP 111110.1011 EMINENT SCHEDULES =gar. — BUILDING 09.101 M1 M AIR DIFFUSER / REGISTER / GRILLE SCHEDULE *,1060 1114 55511 Rpt - PG 5123 nONf3. in F.0 10 47 8¢1821 MEI `01 9.0315 OR. VDMITI 12572 tri. a. 21 1 201.0. 'W *5056 /`/\ On WL 111101 9!2[ 511511 WE1051520® 002 10 1454 45336 • EQUIPMENT S.UNI POWER LEVEL SCHEDUL ml. 34 m 425r2,341:1113....10 4/14 —....;:,:.c:.■. ,50 �_ ..a 11:1.:1102,a..:. X111.15.....11.4......./041.33,1 4 ®1.11..11111211..11 1.1.11•111511.1131.5. 17tP.:4•.1015 1:11..1111.111.11.11..1�.1B:S�:\B!.':. X14 10250 LEGENQ GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES D% ROM Ip 5017 4 00126 D> MU io 00223 50 657916 4 SAZAN GROUP B/8 82.5181.. .1400 bumf. Waste. 24101 ®T5 0029.17/8 Fa 00281.1151 11.../AP 111110.1011 EMINENT SCHEDULES =gar. — BUILDING 09.101 M1 M r) 611 n �P15 LEGEND file ?ri T7 GENERAL NOTES ©MI> moms 1a0 A9 ROAM 0 >i 60 n 105-0.101. 668110 OR USER 013 9157 53090 00 1)0110016 a mom INA N.^1 N1s:��d•71711' K 1pa�mm b NIO� cmr_1moil= eisS•AIlIF AO1 2 O W Um u 51501011 ICAO N NYAb1a OM VAPOR (WON S000J6 1. 0111ANIc A•0n murex vu 9000.0003 0+ 10 N 01010 0 6 511001016 AMOS CCAAb MOO13 SOAOVA 06. 1. 0001010659100-10001110 MOM 5015 0AM STO 0 OE111AU. i mann11¢11410101'"'"'T. KS II C/0 02106 • m 0 551CI601 0510. WKS N CRAP 11 Cr M 11000 IML 011 000601 Al M 11G91 ban 0000 0 S.61 0ON 01 CR 509 11.0C114 0. 5065 ORS 010OWI 10011 CRAW ADO NO 001. MON 01000' M .rmp00 01111 OMTO S 6 MON 106 ( 010605. 000. AWACS 00 0000.161 56106110 .NO]O0L 003 ammucm 00 MSE TAM Al OMR • TIE 5m0c110 5Om1600 Ste OR MMIOf}NIIHORIOSIVIT SO MO YAK 100 ZOO MOffOe9gOS 1. NOS RIM. WO 0100 OK NM MLN[ 000. 0001. RB 0661 60010 000000. 5. mos N=ovum 0sun COMM SRA Na(M 5006 000 1011. 6060116656 NM RACE 11A< nae UA aortm 0e900 OM AAA WAR 0=WC TWO 0816 R6 MCC 0054 A 606S N RNW MO MO 0103 01.100090 NNTM MME 60a 0011. A 60001 6 1100 0 0 RAW 6 M RSA 16[ 030.1.1133). =AM S60G SOL RAM. CO 50000 0066 4591)01000.4101 RASO 10 SOAR 0000 MOOS. ROO 11 11 NN 0-1//10 0 6 la • 9005. 11. 0011E MOOR 5001 OSIa M M 01110 1101 S0R.1. 81061, 0 50l OMAR RSO N OCH MOM M 0111 5500 1)00CO ICA NOIR= 1104[0%1110 ON M PAX 1604001011 A 060 010 00 00 6 110(90: 0//110000 01110 AS MA02 MAW 900.6500011 500611 ti 1106M0 CM 610010500506 111 00006655000. MOM NL00( 0606 006 N6061. 12 0311161103 1109516 005115P00E &0110 10 OWES 6A WIN. OFT01 MOM 10 WAVED MMR 0/LI =MOM 61. 6001000 M0. •' 150 11 ARAM 001[ 051( 10 1 1 08101010 COW 01011c AM MA TO =MC IA MS 900 A9 W. 0FM MCC 01160001 CONSTRUCTION NOTES L 0 86.99 00 00010 9010 (111 1/ ROW 00 RPM .0Mn. M 16� Mil M00•(0OW I >. .POC 1/0 M MAID ACT USA 000 0 RORY 0010001 MOX 1/0 61 014110 0.0 150 55 MAO mr. TS Co OM lorOHAR ARTS SOH ma Rat PARTIAL PLAN VIEW 214004‘0198330 ISSUED FOR CONSTRUCTION 1025.13 SAZAN GROUP mU MWNt1St, 1fd 1500 Soak 0110[00 G001 TY x/.1100 941 900(01.1150 ss 101 101 .011 • • s 0 6gT5251;311 0010 1/r -v- ' OP 1 SART CND 01. al -O3 0009 10111011111110 0 Mt 1100 BOE/ 12 ACC 1111 3131316 BUILDING 09101 REFERENCE DRAWINGS FIR .511010 PO NO0 NOM 0 915 91011 IIF 16, ALAR 1ffi DUCT 00901 Wn1 ¢0. MID CONSTRUCTION NOTES "D'G 0o.41As DA �m1"D&°A°'F� 0160000. M9a 00 )911 1 5010 50 012 4 w�10114u2MW10141:05012 Di> 0404600*0c. 1�m 20006009Q.0005 000 0> 000 041211.19 000 l COM 01. ®0016'1 .010091.1106 ®� vol 41046 f006 MM0 p110A ROM 29 566ri.1000 ®1100 00 400 mac 1MW1ssopa ° °014 1049 65011 1100 0 99 n LEGEND GENERAL NOTES I. 16001411961011100111 0 10 1101 026230 WON 511410 2 NCI 90111 NC OLT 0610ID1 9011 MI 101021010113 1616310*1E1 0 O 00004001 1010(.11 WOE NO 4904101 SPF 40.1 COL 1 06)1011 DCIS AIN 0-0 0 0401 0NW12131 2001 (51I5 121) 130. 0001044. 4 5061911 941411.04 00110112 10 YFEE Ml 60.9014 00101 LOOM N 001102 11. 6 OF 410!1 0)0 020 0961112101 505065 0024PAWS�1MASK KOK 580 04110 4 M 01 O 200 16f DWI 10 0000 006140 0110 MC RV 0910101.04 1 9202100 AA 134014 3 Cr 9900 I¢1. 1 0(11014 1 2. 04 K. 010 806140 40116 u1.=EMIL DICE 006106 1610 11521151912 01 406 0 11E 11101I01AE5 01100 22 101 9.527 5160 01100 3101030014)4 20 NO 0)01 NO .604 macaws. 6 624-6 101145 91010E 9205 IDE 104 100E DOM 044 0210 DDI 1011 eta a 204.051. 1. 12405 1 1619110 01 900104 00001 9011119E 01* 466 f01)110 00601 601001 DE 9906 DE 1101010019 ICE 010140 0010121)0 101219 We O4 91015 00*01004750414016 1 0015 011090 NO Mi 001=100901 02 01400 006 92010 006901 6 0600100 NNE 604 DIES IG 411610. 1.11.1000SLUM A0C ROOEN 05104140 411001. /01150242 129715 040 1e 2110100 L SOU. 0*41139113 92004 90161 401 6 0101 CO 4.3 10a0 0O]6S 4180110 2 M10 2-1/0-101 04.0*. ID 100E 2012222 MICE 1 0100 1 M OG 10 05 0*1.. 29064. O ADAM COMMA 4150 0 001 00101 0.0 AEDE 0101 01404 DPW= ME 0200020 VA 2120192 MOUS MAW AAF 115 Ur 5 IAF 1685026 104 001 41)4 01011 6 RAMC 210605 901 6 00011022 O 003. 11. 00001.101.* 610180 RCN 10 061E 6 IIL 0(1000110 6516. iA 301 01 921 0010136 IOW NO 0161. 12 0113)511014 06049 90 0100001/8 1040106 IOt 0016 MO 631016 0101 9432 0000 NF001101140100.1101401 04 0016 NO 601410 1 00 340 000 00 010601 10 061E 3016 WON 920100101 00 015 POW 10 OG100 RD ASA MC .(01.001 DO No III PS IMO 1,002 •000 10001 RS. 10 101 -1 PARTIAL PLAN VIEW 2019 1NO. -r SAZAN GROUP 00& 06 P00 0106. Pea1f00D 9MM ® T1 010101.1100 EI' 0 Fax 9'6%1.16 1.20. oum 910 1/14-I 10 11. IMO 12 BOE/ 13 CO MO UM. BUILDING 09-101 ..,,' Neudorfer Engineers. Inc. Consulting Eng3noers Seattle Portland Instrument Calibrations Instrument Type Air Data Meter with Flowhood Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M07269 Calibration Due Date 12/23/2014 Instrument Type Tachometer Instrument Manufacturer Shimpo DT -205L Instrument Model Number Type B Instrument Serial # C4AB0095 Calibration Due Date 11/25/2014 Instrument Type Amp Probe Instrument Manufacturer Fluke Instrument Model Number 333 Clamp Meter Instrument Serial # S94210475 Calibration Due Date 12/17/2014 Instrument Type Temperature Probe Instrument Manufacturer Shortridge Instrument Model Number ADM 870 Instrument Serial # M07269 Calibration Due Date 12/23/2014 Instrument Type Air Foil Instrument Manufacturer Shortridge Instrument Model Number ADM 870, Instrument Serial # M07269 Calibration Due Date 12/23/2014 Instrument Type Hydrodata Multimeter Instrument Manufacturer Shortridge Instrument Model Number HDM-250 Instrument Serial # W1007 Calibration Due Date 6/17/2014 globally close to you Product Support STU LZ 12 & 24 Month DRH and DAH Ultrasonic Humidifier Limited Warranty Registration and Start -Up Checklist The 12 Month Precision Limited Warranty applies when the Product Support Network Factory Start -Up is not purchased at the time of order entry. The 24 Month Precision Upgraded Limited Warranty applies only if Factory Start -Up was purchased at the time of Order Entry and Start -Up has been validated by Product Support Installer's Name: Lits Owner's Name: ■ NO Verify the 48 volt DC field wiring size verse length is correct. Refer to Humidifier IOM for wire sizing chart. LTh' S Company Name: . /1ier41-4`1PiitirCompany Name: Q3 A,,,,,,,,,,4______\ ,1, . Street Address: / Street Address: M NO Verify the Factory supplied termination resistor (150 Ohm) is properly installed in the last humidifier on the Modbus loop. City, State, Zip: 544 (j (A! 4 City, State, Zip: Check field wiring for correct termination points. Including field installed humidity sensors, conductivity sensors, etc. Also verify proper installation and mounting of these components. 24s Model Number: 46A q Serial Number: !0'2 `S fer 1 tom2I ies Has the Installation, Operation and Maintenance Manual been supplied with the unit? [PAS ONO If not, when were you told you would receive it? Pre -Start Up Inspection Read The Installation, Operation and Maintenance Manual Before You Do Anything Else! Inspect with humidifier POWER OFF: citt :Oi /®d'2Pito Inspect equipment for damage and inspect the inside of control box and humidifier for any dirt and debris. Lits L2 to Ground: ■ NO Verify the 48 volt DC field wiring size verse length is correct. Refer to Humidifier IOM for wire sizing chart. LTh' S ONO Verify the 48 volt DC field wiring from E -Ultra and Auxiliary Control Boxes to each humidifier is correct per wiring diagrams. Verify the DC voltage polarity is correct. +LYES Q3 • NO Verify field wiring of the Modbus Data Cable connections are correct. Verify connections at every humidifier on the Modbus loop LYES M NO Verify the Factory supplied termination resistor (150 Ohm) is properly installed in the last humidifier on the Modbus loop. ili4S • NO Check field wiring for correct termination points. Including field installed humidity sensors, conductivity sensors, etc. Also verify proper installation and mounting of these components. 24s 1 NO Inspect and tighten all electrical connections ES DNO Inspect drain assembly for proper connections. Drain line diameter should not be reduced in size. FOES iifES ■ NO Inspect water supply connection for leaks. ■ NO Inspect humidifier installation. Humidifiers must be installed in level horizontal position. (ES ■ NO Locate water shut valve on each humidifier. Has the factory supplied strainer been installed? h! r q,,, DYES RIES palo- Purge water lines to humidifier. ■ NO Check and record Incoming main power supply: What is the voltage at maim power terminal block (in volts)? L1 to Ground: 179 L2 to Ground: 7 -7 4 L3 to Ground: Z7 r JO to L2: zg 4 L2 to L3: Q3 L1 to L3:te 1572 Taco Drive, Frederick, MD 21704, U.S.A. • 888.529.1266 ph • 301.620.1396 fx • productsupport@stulz-ats.com www.stulz-ats.com Page 1 of 2 PS -S-027 Rev. C 05/03/12 Product Support STU LZ 111111111111111111111111111111111111111111111111 Tum on main power disconnect ONLY (display will Tight up). u iE . ■ NO Tum on circuit breakers for the primary side of each power supply ONLY. [ ES ■ NO Check and record DC voltage output at each power supply secondary (Vo tage can't exceed 52VDC) ■ U01: 56 _ { UO2: 6-0.. "-e_ UO3: ,TL U04: se , ( U05: *"Completed Warranty Registration/Start Up Form can be submitted to STULZ Alr Technology Systems Inc. for processing either by, Mailing, Faxing or e-mail. Please see bottom of this form for information. U06: U07: U08: U09: U10: ❑ ■ ■ Check and record E -Ultra Series controller software. Version / • 15 Q Date /(/fi4/13 In Service / Humid / Config Menu, assign all humidifiers to a group (A or B) ES ONO Documentation: Was our documentation clear and concise? Address each humidifier and record. Only apply power to the humidifier being addressed. ' (through) ■ Tum on all 48 volt DC circuit breakers and verify the humidifier(s) are communicating to control box. YES ■ NO ■ N/A Check nebulizer temperature inside each. humidifier. If temperature is off more than 2 degrees Celsius, calibrate in service menu. ES • NO Check voltage reading of each humidifier in service menu. If not within 0.2 Volts, calibrate in service menu. [IKS • NO Adjust set point on controller to demand 100% output of each humidifier and record amperages on secondary side of the power sup lies U01: 2-.. UO2: 2,, Si' UO3: 2. g U04: '1, g U05: U08: U07: U08: U09: U10: Site Notes: (i.e. any potential problems�'Ror concerns can be noted for the factoryCto review) ,It .� .— -tires .. /&14 4- C s �,, ►. -.� /ems... , �•�? Qu ty Review: Please ch the num r that you feel best describes how our mpa is pe rming in ea • of the fo owing areas: (On a scale of 0 to 5, where 5 = Excellent, 4 = Very Good, 3 = Good, 2 = Fair, 1 = Poor and 0 = N/A) Start Up Company Information: Technician Name: le,42. f4•'S(" & 1 Qett.� 4/•-• 5 4 3 2 1 0 Product Quality: Do our delivered products meet your order requirements? ■ ■ 0 0 ■ ■ _ QA Date *"Completed Warranty Registration/Start Up Form can be submitted to STULZ Alr Technology Systems Inc. for processing either by, Mailing, Faxing or e-mail. Please see bottom of this form for information. On -Time Delivery: were your products delivered on-time? • ■ ■ ❑ ■ ■ Documentation: Was our documentation clear and concise? 0 0 ■ ■ ■ • Technical Service: Is technical assistance available and provided when required? 1 • • ❑ ■ ■ Recommendation: Would you recommend SATS products? ■ 1 ■ 1 1 ■ Field Service: Do you feel your Factory Start Up was successful ■ ■ ■ ❑ 1 Ili Start Up Company Information: Technician Name: le,42. f4•'S(" & 1 Qett.� 4/•-• _ Start Up Date: 5/ / / if Company Name: .5'\, ,,,`-- n, PSN LST Yes • No 0 N/A Phone: "Za 4- �-z..7.- f e cc Fax: Company Address: 2-7 3 2-34 , A -/e, .s '� -F4-4,41-1e, lA/ tt 753P/ 4t Start Up Technician Signature �� �� " wt QA Stamp Approved _ QA Date *"Completed Warranty Registration/Start Up Form can be submitted to STULZ Alr Technology Systems Inc. for processing either by, Mailing, Faxing or e-mail. Please see bottom of this form for information. 1572 Tiico Drive, Frederick, MD 21704, U.S.A. • 888.529.1266 ph • 301.620.1396 fx • productsupport®stulz-ats.com vwwv.stulz-ats.corn Page 2 of 2 PS -S-027 Rev. C 05/03/12 C 1'3// 2 X 13 ^, i l7/ -- 7$177-- jiGtA 444;4 AAAJ cff 5A i,.i- 7.11449 RIP r/4 Energy labs kit JOB NUMBER: /312-- 7 fJ JOB NAME:#5 B -(t. CONTRACTOR: START UP PERSON: PHONE NUMBER: DATE COMPLETED: N1 -X44...- ,/4 s%q ra ' �.-. ASR HANDLER UNIT FIELD START UP REPOT. 11111 11 111111141111 11 111 J F0 DATE: SA (1 y UNIT TAG: 4 1,1 1 11/ y A4 -42 -tort" Ce / A ''1-0s'%-,w4,1r - Jam'/Z.l /r Yom' AIR HANDLER HAS AN ENERGY LABS CONDENSER UNIT: YES: NO t./" 1- L ZCHECK FOR ANY FREIGHT OR RIGGING DAMAGES. 2.- 3- 4: 5.- 6- 7.- 8. - THE UNIT FORANY MISSING OR INCOMPLETE WORK. VERIFY THAT THE POWER UNES AND GROUND ARE PROPERLY CONNECTED. THE GROUND MUST BE PROPERLY CONNECTED AT BOTH ENDS �-1 CHECK�TO SEE THAT ALL FUSES ARE INSTALLED AND ARE OF CORRECT VALUE -(CHECK WIRING DIAGRAM FOR FUSE INFORMATION.) SURE THAT ALL INSULATIOATfS FASTENED SECURE F.TO TNE`1(NIT GASING. • • RE THAT ALL THE FANS COMPARTMENTS ARE CLEAN, VACUUM ENTIRE UNI, INCL UCT(ON DEBRIS, SCREWS EIC„ - - TNG DUCT POi OF 6ONNtION TO meUNIT. VE -PRELOAD (NOT LO t VE ANY SHIPPING BLOCK FROM UNITS. MAKE SURE THE SPRINGS ARE IN PLACE AND OPERATION AND MAINTENANCE MANUAL) BLOWER ASSEMBLY TO1NSURE,FREEDOM OF'SHAFT ROTATION AND PROPER BELT TENSION AND BEANG LUBRICATION_ iir 9.- 0 CHECK BLOWER ASSEMBLY TO INSURE THAT PULLEYS ARE ALIGNED AIDSECURE • �} 1 I . 10.- HECK FILTERS FOR CLEANLINESS- IF DIRTY, DAMAGED OF .O4 TE, REPLACE IF RECE S RY "' —.J 11. -IC SURE THAT ALL DAM P.ER'LINKAGESARE FREETOMOIJE AND THAT NO 01UDING WILL OCCURREMOVE ANY SHIPMENT TIE DOWNS. • • i41_ j 12- Or THE AIR SUPPLY -AND RETURN OPENINGS, MAKE SURE THE DUCTS HAV$ NO IS'T'RU,,CTIONS,CH�C THAT THE FIRE DAMPERS ARE OPEN. 13.- RLL EMOVE ATHE CARDBOARDS ORANYPOSSIBLE NR OBSTRUCTION FROM THE COILS BErtmt STARTING THE FANS. it Pl KURANY'LOOSE \ i 14.- CHECK FOR LEAKS IN COILS AND PIPING. MAKE SURE ALL JOINTS WHERE UNIT WAS SPUTARE PROPERLY CAULKED. ROOF CLEATS ARE IN PLACE AND CAULKED AND FLOOR CONNECTIONS ARE �CAULKEDAND PROPERLY CONNECTED. 16.- I�.1 IFY THE DRAINAGE *Fr TRAPS ARE INSTALLED ACCORDING WITH THE ENERGY LABS EQUIPMENT INSTALLATION MANUAL " 17.- P! `ER'FY THAT EVERY DOOR IN THE UNIT HAS EVEN GASKET, IS CLOSED AND FULLY SECURED BEFORE STARTING THE FANS, 18- 0 VERIFY THAT ALL DOOR SAFETY SW Tc IES WORK. 1 19- 0 READ AND FOLLOW THE VFD START UP MANUFACTURER PROCEDURES BEFORE ATTEMPT START THE FANS. 20.- MEASURE THE SUP LY VOLTAGE AND MAKE SURE IT IS THE SAME AS SPECIFIED ON THE UNIT NAMEPLATE. L2-L3 if$13 L1-L2 ;•;: 21.- LJ VERIFY THE PROPER ROTATION OF THE SUPPLY FANS. LJ 22.- VERIFY THE PROPER ROTATION OF THE RETURN FANS. El DOES NOT APPLY El DOES NOT APPLY AIR HANDLER UNIT FIELD START UP REPORT. 111 1 1 IIIIIIIIIIII 11111 21.- EYVERIFY THAT ALL FLOW RINGS AND STATIC TIPS ARE CONNECTED AND WORKING PROPERLY 0 DOES NOT APPLY 22.- IEVCHECK THAT ALL CONDUIT CONNECTIONS TO ELECTRICAL PANELS ARE SEALED. CONFIRM THAT THE PANEL IS CLOSED AND PROPERLY LATCHED 23.- 0 VERIFY THAT ALL RAIN HOODS, FURNANCE FLUES AND ATTACHMENTS ARE INSTALLED AND SEALED. 24.- Er:ECK AU. FLOW GAUGES AND COVERS ARE INSTALLED AND OPERATIONAL 25.- Et;.... -.HECK FOR DAMAGED. BLISTERED OR MISMATCHED PAINT. 26.- FiriREAU. SAFETY AND OPERATIONAL LABELS IN PLACE. ELECTRICMOTORS FIELD STARTUP RECORD --• _ _ - Noltage Runbing - !JI gi...."...-DOES NOT APPLY 0 DOES NOT APPLY -'I 1 I ', ••••/ / / MOTOR • DATA FROM MOTOR NAME PLATE Amps RPOI MEASURE THE AMPS AND RPM I L3 RPM SUPPLY fAN 1 • SUP?LY FAN 2 RETURN -FAN 1 - RETURN FAN 2, EXHAUST FAN 1 EXHAUSTFAN-2 7 6'\6 5-7 I • rz -i45--,t. gi...."...-DOES NOT APPLY 0 DOES NOT APPLY -'I 1 I ', ••••/ / / MOTOR • DATA FROM MOTOR NAME PLATE Amps RPOI MEASURE THE AMPS AND RPM I L3 RPM SUPPLY fAN 1 • SUP?LY FAN 2 RETURN -FAN 1 - RETURN FAN 2, EXHAUST FAN 1 EXHAUSTFAN-2 7 6'\6 5-7 I • AIR HANDLER UNIT FIELD START UP REPORT. 111 11 I1111111FI III II III COMMENTS/: • 2 t %G� ir44A44‘14 '0104r 1240' -47 .4V444 ���'V1*--C41 ' "VjLeat ,<ACY1A-1- sf,6"artva=1":44=1;.4"-.4( .(iti-eA-1_ -4"t/ji/41. • i i 11, .' 1-1 I. t 1.1 r f — ' i • l• i i I iii, • .. — -- - _.�� ll ,'1 ( i ( r i'N .' L,' ACCEPTED BY: COMPANY: ENERGY LABS MANUFACTURERS REPRESENTATIVE DATE: To assure full warranty coverage,this report should be signed and retumed by the manufacturer's representative to the Energy Labs service department. Fax:(619) 671-0158 JOB NUMBER: JOB NAME: 3/2--7t(-71.- R4C- CONTRACTOR: je-Id•re-64.....- /4,-?---.Iip _.- AIR HANDLER UNIT FIELD START UP REPORT. 111 11 II II I I II III II III F041 DATE: sAt 1 [ }F UNIT TAG: A 1/ Z.i!! START UP PERSON: /1.4.10 -0 -1 - PHONE .4. 4 - PHONE NUMBER: C v 7 — 6 -4 6C7 - J DATE COMPLETED: 5/71 / / `r' AIR HANDLER HAS AN ENERGY LABS CONDENSER UNIT: YES: NO ANY FREIGHT OR RIGGING DAMAGES. [ CHEEKTHE UNIT FOR ANY MISSING OR INCOMPLETE WORK VERIFY THAT THE POWER LINES AND GROUND ARE PROPERLY CONNECTED. THE GROUND MUST BE PROPERLY CONNECTED AT BOTH ENDS L --I CHECK P SEE THAT ALL FUSES ARE INSTALLED AND ARE OF CORRECT VALUE.(CHECK WIRING DIAGRAM FOR FUSE INFORMATION.) SURE THAT ALL INSULATION -CS FASTENED -SECURELY-TO THEt NIT CASING. 1. .. :I j- .,-r-- 11 i�- - 6 _ LE SURE THAT ALL THE FANS COMPARTMENTS ARE CLEAN, VACUUM ENTIRE UNIT, INCLU ING DUCT POINT OF (bNNEtO TOl'Iig UNIT- PIC(UPANYLOOSE CO UCTION DEBRIS, SCREWS EIC. - _ fl —/ I I t REI�AAOVE ANY SHIPPING BLOCK FROM UNITS. MAKE SURE THE NGS ARE IN PLACE AND VE -PRELOAD (NOT tO . \ / 7'� -- _— OPERATION AND MAINTENANCE MANUAL) ' ' 8.-�Cfi!`CK.BLOWERASSEMBL%TOIHSURE. FREEDOMOF'SHAF.TROtATTONAND PROPERBELTTENSOdAND BEAiINGLUBRICATKNd- 9.- 0 CHECK BLOWER ASSEMBLY TO INSURE THAT PULLEYS AREALIGNED AN• D>SECURE. a!r 10.- HECK FILTERS. FOR CLEANLINESS. IF DIRTY, DAMAGED Ofd LOE, REPLACE IF NECESS I 4 — J SURE THATALL DAMPER'L(NKAGE RARE FREE7014 ?JDEANTHAT NO BID DING WILL OCCUR -REMOVE ANY SHIPMENT TIE DOWNS. 12- l� CHICK THE AIR SUPPLYYIND RETURN OPENINGS, MAKE SURE THE DUCt I{AVd NO 08iTRf ONS,CHE THAT THE FIRE DAMPERS ARE OPEN. 13.- ERE MOVE ALL THE CARDBOARDS ORANYPOSSIBLE AIR OBSTRUCTION FROM THE COILS BEFORE STARTING THE FANS- 14- CHECK FOR LEAKS IN COILS AND PIPING. 15. LTJCAKE SURAND E ALL.JOIPROPERLYWCNTS HEREONNCAULKED,NIT WAS SPIJTARE PROPERLY CAULKED, ROOF CLEATS ARE IN PLACE AND CAULKED AND FLOOR CONNECTIONS ARE ULKED CTED- 16.- I.E VERIFY THE DRAINAGE "I** TRAPS ARE INSTALLED ACCORDING WITH THE ENERGY LASS EQUIPMENT INSTALLATION MANUAL 17._ CJ ' THAT EVERY DOOR IN THE UNIT HAS EVEN GASKET, !S CLOSED AND FULLY SECURED BEFORE STARTING THE FANS, 19... 0 VERIFY THAT ALL DOOR SAFETY SWITCHES WORK. 19- 0 READ AND FOLLOW THE VFD START UP MANUFACTURER PROCEDURES BEFORE ATTEMPT START THE FANS. 161 20.- MEASURE THE SUPPLY VOLTAGE AND MAKE SURE IT IS THE SAME AS SPECIFIED ON THE UNIT NAMEPLATE. ar(V3 L2-L3 21.- t � iVERIFY THE PROPER ROTATION OF THE SUPPLY FANS. • 22.- VERIFY THE PROPER ROTATION OF THE RETURN FANS. DOES NOT APPLY DOES NOT APPLY blew AIR HANDLER UNIT FIELD START UP REPORT. Lain 111110111111111111111 FN41 21.ElDOES NOT APPLY . VERIFY THAT ALL FLOW RINGS AND STATIC TIPS ARE CONNECTED AND WORKING PROPERLY If 22.- LJ j]]CHECK THAT ALL CONDUIT CONNECTIONS TO ELECTRICAL PANELS ARE SEALED. CONFIRM THAT THE PANEL IS CLOSED AND. PROPERLY LATCHED 23.- 0 VERIFY THAT ALL RAIN HOODS, FURNANCE FLUES AND ATTACHMENTS ARE INSTALLED AND SEALED. 24.- l_7 CHECK ALL FLOW GAUGES AND COVERS ARE INSTALLED AND OPERATIONAL 25.- 191 --HECK FOR DAMAGED, BLISTERED OR MISMATCHED PAINT. 26.- IR ARE ALL SAFETY AND OPERATIONAL LABELS IN PLACE ELECTRIC,MOTORS FIELD STARTUP RECORD • C - .Voltage Running • • DOES NOT APPLY DOES NOT APPLY MOTOR DATA FROM MOTOR NAME PLATE MEASURE ME AMPS AND RPM AMPS RPVI! L3 RPM SUPPLY FAN 1 - SUPPLY FAN 2 RETURN: FAN 1 RETURN FAN 2 .EXHAUST FAN 1 EXHAUST FAN -2 1 J.7 r AIR HANDLER UNIT FIELD START IJP REPORT. 111 1 1 HI 111E11 11 111 COMMENTS: . -4444/1424 444:4 AatAr /41411,1---a -47 el4/4014- t 72: 47,&41,PA .4,tzfiy, -1c- rieh. ,a4 delbouurneteX-444 otkp.4,1-.4_ ..4iireAa._ - •• eV0'14- e • ._.. _ _ _____ - __ . ' TI if .- ' -,. .1 H ." .. r'i / , ,• __• _ __,..,..._ , ' 1 1( ,1 'st ::'—'1.,". I 1 ,,• / . \ . ._,.• ' \ ELLI : • . - / [ -, _ 1 ) / , / ACCEPTED BY: COMPANY: ENERGY LABS MANUFACTURERS REPRESENTATIVE DATE: To assure full warranty coverage,. this report should be signed and retumed by the manufacturers representative to the Energy Labs service department. Fax:(619) 671-0158 Dahlgren Industrial, Inc. Number: 114.0 Date Issued: 04/15/14 RFI 114.0 Project Job: Customer: Issued To: BOEING 9-101 ADC 495 BOEING 9-101 ADC GA BOECOM THE BOEING COMPANY THE BOEING COMPANY PO BOX 3707 MAIL STOP OH -56 SEATTLE, WA 98124-2207 Attention: BILL PRINTY PhonelFax: 206 908-8497 / Coordination copies to: POTENTIAL IMPACTS Cost Impact: Schedule Impact: Yes Item: HVAC UPGRADES: AHU Connection Type: STRUC Reference: M622 Spec. Section: Attachments: Description of Request We are unable to locate a detail showing the attachment of the AHU to the platform. Please provide detail drawing. Respond By: 04/22/14 By: CALE VALENTINE Response Attach the AHU's C8 base to the platform decking using ASTM A307 hot -dipped galvanized bolts located within 3" from each end of each section (unit comes in 3 sections) and at 48" o.c. maximum between. At each bolt location drill 7/16" diameter hole through center of C8 bottom flange and 1/4" steel decking below and fasten snug -tight with tapered washer, lock -washer and nut. Washers and nuts shall be hot -dipped galvanized. Tom Hubbell, Casper, Phillips & Associates 2014-04-16 Signed: Date: Proceed as Indicated: Printed by CXv m of 04115/14 830J9AM Owner Authorized Representative Date: OFF HOURS INSPECTION Reimbursement authorization/approval to conduct inspection activities during off hours. Date: 6/3/14 Permit Number: M13-197 Requested By: Erik Westman Firm/Company: Holaday-Parks, Inc. Inspection Information Project Name: Boeing 9-101 ADC HVAC Upgrade Project Address/Location: 9725 E.Marginal Way S. Bldg 9-101 Requested Date for Inspection: 6/4/14 Contact Name: Erik Westman Special Conditions for Consideration: Requested Time: 4:00 AM AM/PM Phone Number: (206) 650-9831 Inspection Scheduled Confirmation #26738 ** Contractor will be charged a minimum for three (3) hour inspection time for any off -hours inspection work at $97.50 per hour (minimum total of $292.50). This is to be paid at the time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of (3) hours. Signature: Printed Name: Erik J. Westman Date: 6/3/14 City Use Only: Approved: Disapproved: Paid: , ' 0 3 Li Receipt No: 12 ,/� —22-61 Date of Approval/Disapproval: Authorized Reviewer: Remarks: JA1.4-ed 6 C( -!j 13 City of Tukwila Department of Community Development November 14, 2013 CONNIE HARDIN 4600 S 134 PL TUKWILA, WA 98168 RE: Correction Letter # 1 MECHANICAL Permit Application Number M13-197 BOEING #9-101 - 9725 EAST MARGINAL WY S Dear CONNIE HARDIN, Jim Haggerton, Mayor Jack Pace, Director RECEIVED NOV 18 2013 HOLADAY-vAKKS, INC, This letter is to inform you of corrections that must be addressed before your development permit can be approved: All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments. Sazan Response 03.19.14 1. Please provide the minimum outside air required per the International Mechanical Code. Section 403 and table 403.3 for the space served by the new air handler. 1. See 09-101-M1 M AHU Schedule for minimum OA value. 2. A duct smoke detector is required to shut the air handler down upon detection of smoke. This detector should be located on the return air side per section 606 of the IMC. Shutdown may also be activated through an area smoke detection system. Please provide the method of activation and show the location of duct detectors on the plans. 3. Note that a Building Permit is required for the air handler platform. 2. See 09-101-1 M24 for duct smoke detector 4. A separate plumbing permit is required for the installation of the backflow device. Please provide a spec sheet with the specific make and model numbers included. This can be submitted with the plumbing permit application and is not needed with this mechanical permit application. 4. See cut sheets (attached) with response. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, er Marshall t Technician File No. M13-197 CORRECTION LTR# y3'11 mt3-- 1'0 RECEIVED CITY OF TUKWILA MAR 2 8 2014 PERMIT CENTER -$10 City of Tukwila Department of Community Development November 14, 2013 CONNIE HARDIN 4600 S 134 PL TUKWILA, WA 98168 RE: Correction Letter # 1 MECHANICAL Permit Application Number M13-197 BOEING #9-101 - 9725 EAST MARGINAL WY S Dear CONNIE HARDIN, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. 1. Please provide the minimum outside air required per the International Mechanical Code, Section 403 and table 403.3 for the space served by the new air handler. 2. A duct smoke detector is required to shut the air handler down upon detection of smoke. This detector should be located on the return air side per section 606 of the IMC. Shutdown may also be activated through an area smoke detection system. Please provide the method of activation and show the location of duct detectors on the plans. 3. Note that a Building Permit is required for the air handler platform. 4. A separate plumbing permit is required for the installation of the backflow device. Please provide a spec sheet with the specific make and model numbers included. This can be submitted with the plumbing permit application and is not needed with this mechanical permit application. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, Jenni er er Marshall Technician File No. M13-197 PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-197 DATE: 03/28/14 PROJECT NAME: BOEING #9-101 - ADC HVAC UPGRADE SITE ADDRESS: 9725 EAST MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Buil g Division Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator n s PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/01/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) DUE DATE: 04/29/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY a PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-197 DATE: 10-29-13 PROJECT NAME: BOEING #9-101 - ADC HVAC UPGRADE SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPA',TMEN S: islon Public Works ❑ ire Prevention Structural Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-31-13 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 11-28-13 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2-28-02 Bld Fire 0 Ping 0 PW 0 Staff Initials: rr w am,. uu.j.nwwW, 1 URWJ1i7 Wi- .gUV Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ❑ Response to Incomplete Letter # Plan Check/Permit Number: M 13 -197 ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-101 Project Address: 9725 East Marginal Wy S —contact Person: Clis-yr.—LA._ `i-A('tot ��-�. Phone Number: Su a ary of Revision: • 77) PJ36p-„ RECEIVE) CITY OFTUKWILA MAR 2 8 2014 PERMIT CENTER Sheet Number(s): IY 1) a� ' Etz 1 ( Re_ (sv.Q� "Cloud" or highlight all areas of revision including dht revkio, Received at the City of Tukwila Permit Center by: 51 ---Entered in Permits Plus on r(J —\ C:\Uurs\Jennifer-m\lksktoplltevision Submittal Form.da HOLADAY PARKS INC • 0 Washington State Department of Labor & Industries • Page 1 of 4 HOLADAY PARKS INC Owner or tradesperson PARKS, GERALD T JR Principals PARKS, GERALD T JR NAILON, JUNE ANNETTEO'CONNOR, BONNY KBECK, DAVID CLARENCEVAN DER VEEN, ERIC M (End: 08/14/2013)PIZZEY, GRACE KATHERINE (End: 08/14/2013)VAN DER VEEN, JULIE ELIZABETH (End: 08/14/2013) CONNELL, DANIEL AARON (End: 08/14/2013) GIRI, BUIT (End: 08/14/2013)KIEL, RINALD HOWARD (End: 08/14/2013)WHITMYRE, CHRISTIAN (End: 08/14/2013)NELSON, MICHAEL (End: 11/04/2010)PARKS, DAVID L (End: 11/04/2010)TALBOT, PAUL (End: 11/04/2010) Doing business as HOLADAY PARKS INC WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA98168 206-248-9700 KING County Business type Corporation Governing persons License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983 — 09/03/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 httos://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 04/10/2014 v = C HAI I CAL HVAC LEG E \ D ICE\ E�AL SYMBOL DESCRIPTION , R RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN TEMPERATURE TRANSMITTER 24/12 - _1,, 24/12 H f f 24/12 - I>(I DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST 4D RECTANGULAR DUCT, RADIUS VANED ELBOW ROUND DUCT, NUMBER INDICATES DIAMETER DUCT TYPE HEAT DETECTOR b 240 9 STATIC PRESSURE REGULATOR 240 TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED f j 0 OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER ON b 24/120 4 24/120 j f SMOKE DETECTOR SUPPLYRECTANGULAAIR R DUECT,OW SQUARE OR LBFACING TOWARDS X I*- —14/I SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY FLEXIBLE DUCT CONNECTION 1'. .' , X t -11S, 100 c M GRILLESIDEWALL OR REGISTERUPPLYAIR ANDDIFFUSERCFM AIR FLOW EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS RANDAIRHAUSTFLOW AIR GRILLE OR REGSIDWALEISTEL RTURN/EX ____Cl _,- 100 CFM HI)EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY SCREENED OPENING AND; CFM AIR FLOW EXHAUSTRE OR AIR OR SQUA RECTANGULARRETURN , AIRELBOW DUCT, FACING TOWARDS , 100 CFM loo SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (4 TYP) EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY 11 -ii -'v-� 400 CFM I` t_____QI, SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) TRANSITION RECTANGULAR TO RECTANGULAR, ROUND TO ROUND OR OVAL TO OVAL i=====1;1 TRANSITION AT TAKE OFF TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL 0 100 CFM UP DUCT OFFSET UP OR DOWN RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW /,r DOWN OPPOSED BLADE DAMPER 3 / _ [ -J.- UNIT HEATER PARALLEL BLADE DAMPER ' i - faSOUND If=7:1;* ATTENUATOR VOLUME DAMPER I!1II• VD VV LINED DUCT WITH AXIAL FLOW FAN DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) -41.DUCT I Ii II (..71 CENTRIFUGAL FAN CENTRIFUGAL FAN W/INLET GUIDE VANES BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) 11. � BDD RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION TIMER SWITCH BLAST GATE DAMPER .f. i PROPELLER FAN AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) MS FD SD FIRE/SMOKE DAMPER (1 HOUR) MEE i FD/SD r f FD2 SD FIRE/SMOKE DAMPER (2 HOUR) IFD2/SDf f ® ELECTRIC MOTOR IN-LINE FAN ROOF CURB MOUNTED EXHAUST FAN (CONTROL SYMBOL) I 1 - - © GES EAL DESCRIPTION SYMBOL DESCRIPTION R W TH ATURN NG VANES SQUARE ELBOW TEMPERATURE TRANSMITTER TT _1,, HUMIDISTAT CEILING H HANDSWITCH HS 4D RECTANGULAR DUCT, RADIUS VANED ELBOW 4H D DUCT TYPE HEAT DETECTOR It STATIC PRESSURE REGULATOR T H TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED am 0 EXTRACTION GRID ON NIGHT THERMOSTAT THERMOSTAT, CEILING SMOKE DETECTOR SD FLEXIBLE DUCT I*- —14/I FLEXIBLE DUCT CONNECTION t -11S, 100 c M GRILLESIDEWALL OR REGISTERUPPLYAIR ANDDIFFUSERCFM AIR FLOW RANDAIRHAUSTFLOW AIR GRILLE OR REGSIDWALEISTEL RTURN/EX _,- 100 CFM SCREENED OPENING AND; CFM AIR FLOW , 100 CFM loo SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (4 TYP) 1,_„1 1 - 11 -ii -'v-� 400 CFM I` SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) gm_ 400 CFM LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) 100 CFM RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW /,r 100 CFM RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED / _ [ -J.- UNIT HEATER LINED DUCT faSOUND ATTENUATOR LINED DUCT WITH ACCESS DOOR AND SMOKE DAMPER I!1II• LINED DUCT WITH AXIAL FLOW FAN I Ii (..71 CENTRIFUGAL FAN CENTRIFUGAL FAN W/INLET GUIDE VANES ::= SUPPLY AIR FLOW DIRECTION RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION TIMER SWITCH PROPELLER FAN MOTOR STARTER MS GE\EAL SYMBOL DESCRIPTION THERMOSTAT, REMOTE, CEILING R TEMPERATURE TRANSMITTER TT HUMIDISTAT CEILING H HANDSWITCH HS 4D DUCT TYPE SMOKE DETECTOR 4H D DUCT TYPE HEAT DETECTOR 2 STATIC PRESSURE REGULATOR T H TEMPERATURE SENSOR, HUMIDITY SENSOR, DUCT MOUNTED am 0 SPACE TEMPERATURE SENSOR ON NIGHT THERMOSTAT THERMOSTAT, CEILING SMOKE DETECTOR SD SEPARATE Do ►T REQUIRE woolliest 14,seettlW Plumbing. Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ReviSigns will require anew plan submittal NOTE review fees. and may include additional plan SUGGESTED A3 3 EVIATI O \ S ABBREVIATION DESCRIPTION A AAV AD ADD AF AFF AHU AP AUD AVG BI BDD BFP BHD BHP BOD BOP BOS BTU BTU H BW C CV Cv °C CAP CC CCW CFM CH CI A CONN CCPU CRU CW CWP DA DB DBD DIA, 0 DIS DIR DN DS DWG dB EA EAG EAT EFF ELL ELEV, EL ESP EVAP EWT EXH EXIST EXT F °F FC FCO FD FH FLR FO FOB FOF FOIC FOT FPM FS FT FUD FV GAL GPM GALV GA HC HD HORIZ HP H PC HR HVAC HPU HTG HW ID IE IGV IWC KW KVA ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR AIR HANDLING UNIT ACCESS PANEL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON CONSTANT VOLUME FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CANOPY HOOD CAST IRON CENTER LINE CONNECTION COUPLING CONDENSATE PUMP UNIT COMPUTER ROOM COOLING UNIT CLOCKWISE ROTATION, COLD WATER(DOMESTIC) CHILLED WATER PUMP DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DEIONIZED WATER SUPPLY DEIONIZED WATER RETURN DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH EXHAUST AIR GRILLE ENTER AIR TEMPERATURE (°F) EFFICIENCY ELBOW ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL FILTER TEMPERATURE - DEGREES FAHRENHEIT FORWARD CURVE WHEEL FLOOR CLEAN OUT FIRE DAMPER FUME HOOD FLOOR FAIL OPEN FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FLOW SWITCH FEET FUNNEL DRAIN FACE VELOCITY (FPM) GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING DOMESTIC HOT WATER INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INCHES INDUSTRIAL WASTE CONTAINMENT KILOWATT KILOVOLT -AMPERE REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City T viiia BUILDIN D VISION SUGGESTED A3 3 EVIATIO\S ABBREVIATION DESCRIPTION LAT LBS, # LWT MA MAX MBH MCC MIN MOV MTD, MTG NC NIC NO NTE NTS NPSH OA OBD OF OS&Y OD PBD PD/LP PDI POS PRESS PRV PS PSIG PSV PDC PDS RA RECT REF RH RM ROT RPM REQD RTN S SA SAG SAR SCFM SD SHC SHF SO SOV SP SQ SRV SS STL SW SUCT SV TT TDH TEMP TH THC THD TH RD TOD TOS TOP TP TPV TS TSP TV TYP UBD UH V VAV VSD VD VP VERT VTA VTR WB WG W/ WCO WHA LEAVING AIR TEMPERATURE (°F) POUNDS LEAVING WATER TEMPERATURE CO MIXED AIR MAXIMUM HEAT CAPACITY (1000 BTUH) MOTOR CONTROL CENTER MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO EXCEED NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE - POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE PRESSURE DIFFERENTIAL CONTROL PRESSURE DIFFERENTIAL SWITCH REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN SPRINKLER SUPPLY AIR, SOUND ATTENUATOR SUPPLY AIR GRILLE SUPPLY AIR REGISTER CUBIC FEET OF AIR, AT STANDARD CONDITIONS SMOKE DETECTOR SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SQUARE SAFETY RELIEF VALVE STAINLESS STEEL STEEL SOCKET WELD SUCTION SAFETY RELIEF VALVE TEMPERATURE TRANSMITTER TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE, TRAP PRIMER TRAP PRIMER VALVE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL UP BLAST DISCHARGE UNIT HEATER VENT VARIABLE AIR VOLUME VARIABLE SPEED DRIVE VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WATER GAUGE (INCHES OF WATER) WITH WALL CLEAN OUT WATER HAMMER ARRESTOR LEGE \J GE\ERAL NOTES DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EQUIPMENT SCHEDULES. DIFFUSERS WITHOUT ARROWS TO INDICATE AIR FLOW DIRECTION ARE FOR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. 3. ALL MATERIALS, EQUIPMENT AND INSTALLATIONS SHALL CONFORM TO PROJECT #12281.00 SPECIFICATIONS 4. HVAC DUCT SHALL BE SEALED PER THE REQUIREMENTS OF THE WSNREC AND SPECIFICATION 15800. 5. DUCT INSULATION SHALL BE PER THE REQUIREMENTS OF THE WSNREC AND SPECIFICATION 15290. 6. AIR BALANCING SHALL MEET THE REQUIREMENTS OF THE WSNREC AND SPECIFICATION 15990. 7. MECHANICAL COMMISSIONING SHALL BE PER THE REQUIREMENTS OF THE WSNREC AND SPECIFICATION 15990. EFE CE AWI \GS CO\ST UCTIO\ COTES FILE COPY Peril* NOrnaift fahrt review a p b aubjact to enom and O on& Approval of commotion dominants does not authorize the violation of any adopted code orerdhiance. Receipt of . 1sa4110wiNted: RECEIVED CITY OF TUKWILA our 2.92013 PERMIT CENTER 1617 mii7UMW 111111111E 4114. , City lialeadat LDINIG DIVISION 21406-W01969369 ISSUED FOR CONSTRUCTION 10 25.13 AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 2 A CAFETERIA - IFP CAFETERIA - IFC ADC HVAC UPGRADE 12254733 12254733 21406-W01969369 HGI HGI SAZAN/FPW SEL SEL 06.04.12 06.18.12 10.25.13 giAKAPAEMAge Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN CHECKED DATE SUBTITLE HVAC LEGENDS & ABBREVIATIONS CURRENT REVISION 21406-W01969369 SYMBOL A DATE 10.25.13 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 DEV. CENTER, WA SHEET MOA JOB NO. 12254733 COMP NO. DWG NO. 09 -101 -MOA A R -ACL\G\ITS EQUIPMENT AREA SERVED FAN COOLING COILS HEATING COILS AIR FILTERS REMARKS CF OA CFM (MIN) TI L S.P. IN 20 FAN SIZE FAN RPM VOLT / PH BHP HP 24x24 ENTERING AIR T LEAVING AIR T WATER °F COIL MAX. FRICTION (RG) ENT. AIR LV. AIR HOT WATER MIN. FACE MAX. FRICTION MAX. FACE VEL: TYPE AIR FRICTION MAKE & MODEL OR APPR. EQUAL CFM DRY BULB WET BULB DRY BULB WET BULB GPM ENT. TEMP. LV. TEMP. MIN. FACE MAX. FINS. MIN. ROWS AIR WATER CFM ' FD.B. ' FD.B. EWT LWT GPM MAX. FINS. ROWS AREA SQ. FT. AIR WATER AH2N13 ADC (SUPPLY) 5,0' 410 '•.25 182 CLASS 2 2341 460/3 6.0 7.5 10 IN H2O FT H2O 6 IN H2O FT H2O 497 FPM MERV 8 MERV 14 0.16 0.41 PRE -PLEAT 40 LPD RIGID AIR 1,2,3,4,5,6,7,8,9 5,000 80 65 54.3 53.9 23.6 42 56 10.1 F1-2 FPI 6 0.81 2.7 5,000 45 91.1 180 160 10.0 FPI 2 10.1 0.15 3.75 AH2N13 ADC (RETURN/EXHAUST) 5,000 - 2.0 182 CLASS 1 1819 460/3 2.6 5.0 - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - 1,2,3,4,5,6 1. DIRECT DRIVE PLENUM FANS 2. VFD PROVIDED BY OTHERS 3. INTERNAL FAN ISOLATION, 2" SPRING DEFLECTION 4 TEFC PREMIUM EFFICIENCY MOTOR 5. DUAL DISCONNECT 6. 25KA SCCR 7. MAGNAHELIC GAGE FOR FLOW MEASUREMENT OF SUPPLY AIR AND RETURN AIR 8. ULTRASONIC HUMIDIFIER, CONTROLS AND DI WATER TREATMENT, 150 LB/H, STULTZ HUMIDIFIER DAH -30-S (4 REQUIRED), STULTZ CONTROL PANEL ULS-4-DAH-30, STULTZ WATER TREATMENT 2©2.2 CU FT MIXED MEDIA BOTTLES. HUMIDIFERS MOUNTED IN AHU DISCHARGE, CONTROL PANEL AND WATER TREATMENT SHIPPED SEPARATELY FOR FIELD INSTALLATION 9. ENERGY LABS MODEL C-042-056-FCH-L AR DIFFUSER / REGISTER / CILLE SCHEDULE MARK NUMBER TYPE MATERIAL FINISH INLET NECK SIZE, INCHES) FACE SIZE (INCHES) MAX. TP INCH WG. MAX. NOISE COEFFICIENT MAXIMUM SET CFM MAKE/MODEL REMARK (CD) SQUARE SUPPLY DIFFUSER STEEL WHITE 12x12 24x24 0.08 25 600 MDS 77 (RG) EGGCRATE RETURN GRILLE ALUMINUM WHITE 18x18 20x20 0.07 19 1450 TI US 86 93 91 87 81 79 77 SUPPLY FAN OUTLET 82 80 93 93 EQUIPMENT SOU\D POWER LEVEL SCHEDULE EQUIP NO MAX SOUND POWER LEVEL dB RE 10-12 W REMARKS OCTAVE BAND CENTER FREQUENCY HZ 63 125 250 500 1000 2000 4000 8000 AHU2N13 80 79 90 84 81 78 77 75 RETURN FAN OUTLET 77 76 89 79 73 72 72 71 RETURN FAN INLET AHU2N13 87 86 93 91 87 81 79 77 SUPPLY FAN OUTLET 82 80 93 93 84 84 82 79 SUPPLY FAN INLET REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION LEGEND GE \EAL NOTES REFERENCE DRAWI \GS CO\ STRUCTION \OTES PROVIDE NEW AH2N13 AS SCHEDULED PROVIDE NEW GRILLES AND DIFFUSERS' SCHEDULED. CORRECTION LTR#_. 13lq7 21406-W01969369 DPD REVIEW 03.17.14 RECEIVED CITY OF TUKWILA MAR 2 8 2014 PERMIT CENTER AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ADC HVAC UPGRADE 21406-W01969369 SAZAN/FPW 10.25.13 A ADC HVAC UPGRADE DPD REVIEW 21406-W01969369 SAZAN/DJ 03.17.14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION 21406-WO1969369 SYMBOL A DATE 03.17.14 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ADC HVAC UPGRADE BUILDING 09-101 MECHANICAL MASTER DEV. CENTER, WA SHEET M1M JOB N0. COMP NO. DWG NO. 09-101-M1M PIPE IDE\TIFICATIOk GENERAL SYMBOL DESCRIPTION ❑ DF NEW WORK WR ELECTRIC WATER COOLER EXISTING WORK FFD iiiiiii EXISTING TO BE REMOVED - - ELECTRIC WATER COOLER FOR HANDICAPPED HIDDEN OR BELOW GRADE FUNNEL DRAIN // INSTRUMENT, PNEUMATIC SIGNAL CONTROL AIR // LAVATORY, ROUND COUNTER MOUNT CROSSING LINES, NO CONNECTION IN LAV CONNECTING LINES I$i ATIO EQUIPMENT MARK NUMBER \ 1 f CLD CENTRIFUGAL PUMP SERVICE SINK, WALL HUNG CPI SERVICE SINK, FLOOR MOUNT AIR OPERATED DOUBLE DIAPHRAGM PUMP F- LATERAL O INSULATED PIPE FLOOR DRAIN WYE AND SHOWN WIT1/8CBEND, CLEANOUT _ O INSULATED PIPE WITH ELECTRIC HEAT TRACING - - >3( -•- POINT OF CONNECTION UR URINAL, WALL HUNG FIXTURES SYMBOL DESCRIPTION ❑ DF DRINKING FOUNTAIN WR ELECTRIC WATER COOLER ARGON GAS FFD EWC O - - ELECTRIC WATER COOLER FOR HANDICAPPED FUD FUNNEL DRAIN EWCH CHEMICAL DRAIN Q LAV LAVATORY, ROUND COUNTER MOUNT C) IN LAV LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT 1 EWF SAFETY EYE WASH FOUNTAIN CLEAN OUT, FLOOR CLD SS SERVICE SINK, WALL HUNG USS SERVICE SINK, FLOOR MOUNT ORD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) LATERAL O FD FLOOR DRAIN WYE AND SHOWN WIT1/8CBEND, CLEANOUT _ O FS FLOOR SINK >3( SHOWER STALL AND FIXTURE CTFS- UR URINAL, WALL HUNG 1:DWC WATER CLOSET, FLUSH VALVE, WALL HUNG C WC WATER CLOSET, FLUSH VALVE, FLOOR MOUNT O CIRCULAR WASH FOUNTAIN Q SEMI -CIRCULAR WASH FOUNTAIN 41 SSEW SAFETY SHOWER AND EYE WASH O SAFETY SHOWER DW DISTILLED WATER WASTE FITTINGS SYMBOL DESCRIPTION A 0 WR WASTE RECEPTOR, ROOF ARGON GAS FFD FUNNEL FLOOR DRAIN O - - C FUD FUNNEL DRAIN O CHEMICAL DRAIN TD TRENCH DRAIN C) - - CO CLEAN OUT, EXPOSED 1 -0 FCO CLEAN OUT, FLOOR CLD CLEAR WATER DRAIN WCO CLEAN OUT, WALL COOLING WATER RETURN - I LATERAL I CRV CO WYE AND SHOWN WIT1/8CBEND, CLEANOUT _ I 1/4 BEND CTFR- COOLING TOWER FILTER RETURN -0 CTFS- COOLING TOWER FILTER SUPPLY + PIPE IDENTIFICATION SYMBOL DESCRIPTION A COMPRESSED AIR, PLANT - AR ARGON GAS - AW ACID WASTE - - C CONDENSATE RETURN (GRAVITY) - CD CHEMICAL DRAIN - - CF CHEMICAL FEED - - CHWR- CHILLED WATER RETURN - CHWS- CHILLED WATER SUPPLY - CLD CLEAR WATER DRAIN PRESSURE REGULATING VALVE CLWR- COOLING WATER RETURN - CLWS- COOLING WATER SUPPLY - CRV CORROSION RESISTANT VENT GC CRS CORROSION RESISTANT WASTE 0 CTFR- COOLING TOWER FILTER RETURN -0 CTFS- COOLING TOWER FILTER SUPPLY + CTWR- COOLING TOWER WATER RETURN PIPE TEE, OUTLET UP OR TOWARD CTWS- COOLING TOWER WATER SUPPLY - CW DOMESTIC COLD WATER BALANCE VALVE W/0 METERING PORTS DI DEIONIZED WATER -I>t<1 DW DISTILLED WATER III F FIRE LINE, AHEAD OF ALARM VALVE PIPE ELBOW, 90° SHORT RADIUS FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY I FOV FUEL OIL VENT FLOAT VALVE G NATURAL GAS PIPE ELBOW, 45° GW GREASE WASTE GN2 GASEOUS NITROGEN D - HWDC - HAZARDOUS WASTE DOUBLE CONTAINMENT HGD- REFRIGERANT HOT GAS DISCHARGE PIPE CAP SCREWED OR SOLDER JOINT HPR- CONDENSATE RETURN (PRESSURE) VALVE IN RISER (TYPE SPECIFIED) HPS - STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) HPW - HOT PROCESS WATER HPWC- HOT PROCESS WATER CIRCULATING II - HW - DOMESTIC HOT WATER SUPPLY HWC- DOMESTIC HOT WATER CIRCULATING KI HWR HEATING WATER RETURN REDUCING PIPE FLANGE HWS- HEATING WATER SUPPLY - HMU- HUMIDIFIER MAKE UP IA INSTRUMENT AIR ID INDIRECT DRAIN X IW INDUSTRIAL WASTE / - IWDC INDUSTRIAL WASTE DOUBLE CONTAINMENT - IWC INDUSTRIAL WASTE CONTAINMENT SPRING HANGER - IWDCV - INDUSTRIAL WASTE DOUBLE CONTAINMENT VENT - IWCV - INDUSTRIAL WASTE CONTAINMENT VENT PIPE GUIDE LN2 LIQUID NITROGEN I - LPC- LOW PRESSURE CONDENSATE - LPS- STEAM SUPPLY (LOW PRESS, 0-15 PSIG) MPS- STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) OFD - OVERFLOW DRAIN - - PUMPED CONDENSATE - PC PCWS- PROCESS COOLING WATER SOURCE - PCWR - PROCESS COOLING WATER RETURN PIPE IDENTIFICATION SYMBOL DESCRIPTION - PR CONDENSATE RETURN (PUMPED) - - PW PROCESS WATER - RD REFRIGERANT DISCHARGE - - RHG- REFRIGERANT HOT GAS - RL REFRIGERANT LIQUID - - RS REFRIGERANT SUCTION (GAS) - - RWL RAIN WATER LEADER SLOPE S SPRINKLER LINE SOLDERED FITTING SAN SANITARY WASTE ABOVE GRADE OR FLOOR PRESSURE REGULATING VALVE SAN SANITARY( WASTE BELOW GRADE OR FLOOR SOL SOLVENT W. STS STORM DRAIN ABOVE GRADE OR FLOOR GC STS - STORM DRAIN BELOW GRADE OR FLOOR 0 TPC -R- TEMPORARY PROTECTIVE COATING - REMOVAL -0 TW - TEMPERED WATER + V VENT PIPE TEE, OUTLET UP OR TOWARD 0I PIPE TEE, OUTLET DOWN OR AWAY 01 PIPING FITTINGS PIPE FITTINGS SYMBOL DESCRIPTION X Y PIPING MATERIAL CHANGE, X TO Y SPRINKLER HEAD, PENDENT, IN LINE, NEW ( UNION, FLANGED -111- SCREWED FITTING OR AS SPECIFIED I I HB GLOBE VALVE, OPEN / CLOSED FLANGED FITTING -II II- BREAK IN PIPE --I T WELDED FITTING BUTTERFLY CONTROL VALVE SLOPE DIRECTION OF SLOPE, DOWN LIFT CHECK VALVE SOLDERED FITTING o o PRESSURE REGULATING VALVE IA BELL & SPIGOT PRESSURE REGULATING VALVE W/EXT. PRESS TAP 1 W. SOLVENT CEMENT Ov GC GROOVED COUPLING p'41 0 FH BUSHING -0 O PIPE TEE, STRAIGHT + -OI ® PIPE TEE, OUTLET UP OR TOWARD 0I PIPE TEE, OUTLET DOWN OR AWAY 01 DRY PIPE VALVE BALANCE VALVE W/0 METERING PORTS PIPE UNION i T -I>t<1 M PIPE CROSS III 2 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR PIPE ELBOW, 90° SHORT RADIUS ISR PETCOCK PIPE ELBOW, 90° LONG RADIUS II_ I -D PIPE ELBOW, REDUCING FLOAT VALVE {WIV PIPE ELBOW, 45° O —� PIPE ELBOW, TURNED UP OR TOWARD IO D PIPE ELBOW, TURNED DOWN OR AWAY I-0 A I- PIPE CAP SCREWED OR SOLDER JOINT 4 WAY EARTHQUAKE BRACING 1 VALVE IN RISER (TYPE SPECIFIED) PIPE CAP, WELDED OR GROOVED D v BLIND FLANGE II i PIPE PLUG I KI VALVE BOX REDUCING PIPE FLANGE Ip PIPE REDUCER CONCENTRIC of PIPE REDUCER ECCENTRIC COOLING COIL CHILLED WATER PIPE ANCHOR X PIPE HANGER / AUTOMATIC AIR VENT (WITH DRAIN) SEISMIC HANGER /S PRESSURE GAUGE WITH VALVE SPRING HANGER 11 THERMOMETER, LINE MOUNT PIPE GUIDE THERMOMETER, SEPARABLE WELL MOUNT I PIPE SUPPORT 1 PIPING FITTINGS SYMBOL DESCRIPTION -D4- / -►�- FLEXIBLE PIPE CONNECTION A EXPANSION JOINT SPRINKLER HEAD, PENDENT, IN LINE, NEW -11- UNION, FLANGED -111- UNION, SCREWED -I0I- / -ICI- HOSE BIBB HB GLOBE VALVE, OPEN / CLOSED NON FREEZE HOSE BIBB NFHB -Z Z- BREAK IN PIPE --I T DIRECTION OF FLOW BUTTERFLY CONTROL VALVE SLOPE DIRECTION OF SLOPE, DOWN LIFT CHECK VALVE PIPING SPECIALTIES SYMBOL DESCRIPTION -D4- / -►�- GATE VALVE, OPEN / CLOSE A GATE VALVE, OUTSIDE SCREW AND YOKE SPRINKLER HEAD, PENDENT, IN LINE, NEW --F1.1{ PETE'S PLUG, WITH BALL VALVE GATE VALVE, WITH HOSE CONNECTION ix] -I0I- / -ICI- BALL VALVE, OPEN / CLOSED /-D<- GLOBE VALVE, OPEN / CLOSED re ANGLE GLOBE VALVE, ELEVATION / PLAN -I;=(F /N XF BUTTERFLY VALVE OPEN / (NC) NORMALLY CLOSED --I T H- BUTTERFLY CONTROL VALVE � -L1- / LIFT CHECK VALVE --i�-- SWING CHECK VALVE WITH FLOW TRAP SEAL PRIMER VALVE PRESSURE REGULATING VALVE IA PRESSURE REGULATING VALVE W/EXT. PRESS TAP 1 W. PRESSURE REGULATING VALVE (SELF CONTAINED) Ov /P PRESSURE RELIEF VALVE / SAFETY VALVE p'41 MOTOR OPERATED VALVE FH VACUUM CLEANING OUTLET SOLENOID OPERATED VALVE O NITROGEN OUTLET /N\ NEEDLE VALVE ® LIQUID NITROGEN DROP BALANCE VALVE WITH METERING PORTS 01 DRY PIPE VALVE BALANCE VALVE W/0 METERING PORTS ISI �� i T -I>t<1 M 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR MONITOR SWITCH 2 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR FLOW SWITCH ' GC_9C; PETCOCK I PLUG VALVE / STOP COCK I -D POST INDICATOR VALVE, YARD FLOAT VALVE {WIV WALL INDICATOR VALVE, PLAN / ELEVATION O —� QUICK OPENING VALVE D QUICK CLOSING VALVE, FUSIBLE LINK A I- PLUG VALVE/STOP COCK 4 WAY EARTHQUAKE BRACING -KCS-- VALVE IN RISER (TYPE SPECIFIED) UNCLASSIFIED VALVE 11- v --C=1 FLOW METER, VENTURI TYPE i FLOW METER ORIFICE I O VALVE BOX WYE STRAINER (WITH DRAIN VALVE) HEATING COIL QI- COOLING COIL CHILLED WATER - - Q- —A'4" AUTOMATIC AIR VENT (WITH DRAIN) -MAV MANUAL AIR VENT (WITH DRAIN) PRESSURE GAUGE WITH VALVE I I 11 THERMOMETER, LINE MOUNT f THERMOMETER, SEPARABLE WELL MOUNT TEST PLUG II PIPING SPECIALTIES SYMBOL DESCRIPTION A / A AIR DROP, SIMPLEX / DUPLEX 6 / € AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX SPRINKLER HEAD, PENDENT, IN LINE, NEW --F1.1{ PETE'S PLUG, WITH BALL VALVE -RPBPH- BACKFLOW PREVENTER _VI 400 AUTOMATIC FLOW CONTROL VALVE V T TEMPERATURE CONTROL AIR SOURCE TRAP, FLOAT SPRINKLER HEAD, DRY PENDENT -01111-- --I T 1-- STEAM TRAP ,' --i EXISTING SPRINKLER HEADS (REMOVE) TP TRAP SEAL PRIMER VALVE FHC A FIRE DEPARTMENT CONNECTION, WALL TYPE VACUUM DROP (LAB VAC) FDC.. Ov FDC VACUUM OUTLET (LAB VAC) HARD PIPED LJ v FH VACUUM CLEANING OUTLET 4d FH O NITROGEN OUTLET /N\ NITROGEN DROP ® LIQUID NITROGEN DROP WATER HAMMER ARRESTOR 01 DRY PIPE VALVE FILTER ISI �� i T PULSATION DAMPENER M FIRE PROTECTION SYMBOL DESCRIPTION --0 SPRINKLER HEAD, UPRIGHT, NEW AO -4- SPRINKLER HEAD, PENDENT, IN LINE, NEW ENERGY MANAGEMENT AND CONTROL SYSTEM DI SPRINKLER HEAD, PENDENT, OFFSET, NEW I- _____V__. SPRINKLER HEAD, SIDEWALL, PENDENT, NEW V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW TEMPERATURE CONTROL AIR SOURCE - - SPRINKLER HEAD, DRY PENDENT -01111-- SPRINKLER HEAD, OVER AND UNDER X EXISTING SPRINKLER HEADS (TO REMAIN) ,' --i EXISTING SPRINKLER HEADS (REMOVE) FIRE HOSE CABINET FHC FDC Y FIRE DEPARTMENT CONNECTION, WALL TYPE FDC.. FIRE DEPARTMENT CONNECTION, YARD TYPE FDC FIRE DEPARTMENT CONNECTION, FLUSH LJ T -I FH FIRE HYDRANT - 2 HOSE OUTLET 4d FH FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER CONNECTION ® ASR AUTOMATIC SPRINKLER RISER T WMG WATER MOTOR GONG ELECTRIC BELL 01 DRY PIPE VALVE ISI �� ALARM VALVE, WET M MONITOR SWITCH 2 FLOW SWITCH ' GC_9C; GROOVED COUPLING, GROOVED CAP THRUST BLOCK POST INDICATOR VALVE, YARD {WIV WALL INDICATOR VALVE, PLAN / ELEVATION O HALON SYSTEM AUTOMATIC DISCHARGE STATION D HALON SYSTEM, MANUAL DISCHARGE STATION I 2 WAY EARTHQUAKE BRACING X 4 WAY EARTHQUAKE BRACING WELDING SYMBOL DESCRIPTION ROOT OPENING DEPTH OF FILLING FOR PLUG AND SLOT WELDS EFFECTIVE THROAT SIZE OR STRENGTH FOR CERTAIN WELDS FINISH SYMBOL CONTOUR SYMBOL F A \S {OTSIDEHER }L -P BOTH SIDES} ARROW SIDE (N) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED BASIC WELD SYMBOL OR DETAIL REFERENCE TAIL (MAY BE OMITTED WHEN REFERENCE IS NOT USED SPECIFICATIONS, PROCESS OR OTHER REFERENCE GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL ARROW CONNECTING EFERENCE LINE TO ARROW SIDE OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS BACK WELD FILLET WELD PLUG OR SLOT WELD SQUARE WELD 0 SPOT OR PROJECTION WELD EVIEVVED FOR CODE COMP APPR VED APR 032Q14 City of Tum UILDING DIVISION VEMMINNEW CONTROLS SYMBOL DESCRIPTION Al ANALOG INPUT AO ANALOG OUTPUT EMCS ENERGY MANAGEMENT AND CONTROL SYSTEM DI DIGITAL INPUT DO DIGITAL OUTPUT DDC DIRECT DIGITAL CONTROL O TEMPERATURE CONTROL AIR SOURCE kAi') 1 Com/ 7 RECEIVED CITY OF TUKWILA OCT Z 9 2013 PERMIT CENTER 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 I A/AN GROUP 00 Stewart St., Ste 1400 eattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 1 CAFETERIA — IFC 12254733 HGI SEL 06.04.12 2 CAFETERIA — IFC 12254733 HGI SEL 06.18.12 A ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 cii___AnsrAwrivAv Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED EN GINEE R SUBTITLE PIPING LEGEND AND ABBREVIATIONS CURRENT REVISION 21406-W01969369 SYMBOL A DATE 10.25.13 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 RENTON, WA SHEET MOB JOB NO. 12254733 COMP NO. DWG NO. 09 2101 -MOB SECURITY BAR, SEE DWG. 83—BMAC-1 AIR EXTRACTOR (TYP.) 720" NECK DIFFUSER 22/14 1425 CFM, TYPICAL (8) PLACES 26/14 22/14 N CO N N N [19 1M18 4553-M3 10x10 DIFF 321CFM 15x15 RETURN 643CFM It It B VCBC-20 1750 CFM O 10 9x9 DIFF 291CFM 15x15 RETURN 875CFM 9x9 DIFF 291CFM 9x9 DIFF 291CFM E DWG 109-1`01-4553—M5 FOR DUCTWORK FEEDING MEZZANINE OFFICE AR (8) 4x 2 GRILLES ® 1500 CFM EA. SEE DET. 1M18 1 d r L_ 120 1/8 x 50 1/2 ► ILTER SECTION 64/24 ABOVE FROM AHU #11 64/24 BELOW FROM AHU #9 2000CSM, /\ TURNING VANE ff 0'-0 78/24 (2) 36x18 GRILLES 1800 CFM EA. 8� HUMIDIFIER 1M18 M601 Ci 4 EL. 20'-6" ' F B.O. 'DUCT 161-0" 4559-M3 20000 CFM WALL TRANSFER FAN NOM 225 CFM MAN BARRE i 140 12x12 GRILL SOUND BAFFLE ENCLOSURE FOR CONST. DETAILS SEE SKETCH NO. 35D083208 RD CEILING DIFFUSER 180 NECK 1200 CFM (TYP 2) MAN B RAG -1 1020 CFM 42" X 38" 18/12 EXHAUST DUCT ROM EFO1L12A T� ROOF. 180 16/18 140 180 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION SAR-1, 36/12 1250 CFM (4) TYP. 201'0 22 GA GALV. LONGITUDINAL WELDED SEAM DUCTWORK 48x24 RA GRILLE 2200 CFM MAN BARRED AHU #27 (REF ABOVE) 36/18 UP, SEE DWG 109-101-4565—M PARTIAL PLA\ VIEW SCALE: 1/8"=1 36/18 /8"=1 0" 80 t 80 60 20/16 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGE\D GE\PAL OTES FILTERS INSIDE AIR HANDLERS: 2" 3M MERV 12 MINI -PLEAT. NO BAG FILTERS ARE USED; BAG FILTER HOUSINGS ARE ABANDONED IN PLACE. REFEH\CE DAWI \GS ENOVAL \OTES REMOVE (E) SUPPLY AIR DUCT, DIFFUSERS, SUPPORTS, INSULATION AND APPURTENANCES. REMOVE (E) RETURN AIR DUCT, GRILLES, SUPPORTS, INSULATION AND APPURTENANCES. M(3- X97 RECEIVED CITY OF TUKWILA OCT 192013 PERMIT CENTER .AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 \ 11 REMOVAL \IIII„ ■!III 1 T �?- -V T T T T� 1M10 1M11 1M12 1M13 1M14 1M15 1M16 1M17 1 1/1B 1M19 1M20 1M21 1M22 1M23 1M24 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 1M34 1M35 1M36 1M37 1M38 1M39 1M40 1M41 1M42 1M43 1.044 1M45 1M46 KEY P_AN SCALE: NONE 4' 11 19 so 23 16' NM SCALE: 1 /8"=1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE K ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 F G C D E ADD EXHAUST SYSTEM AS BUILD VACATE ESS 74747901 74747901 7180376 SPR SPR HARRAH 7/28/95 2/5/96 5/3/99 H J RELOCATE TEST EQUIPMENT ADD 2 SUPPLY GRILLES COL. K-10.5 RELOCATED HK VAC TO DWG. 1M368 CABINET & CABLE SHOP RELOC. REFURBISH AHU#9 — ADC 400K CLEANROOM 190106-18 57639900 18040606 11305389 KGP HARR S.RUDELL HARR HARR RWS RWS RWS 11/20/00 10/09/07 03.19.08 11/04/08 03/30/11 QiBOE/NG' Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DUARTE CHECKED DATE 2/11/94 SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION 21406401969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE MMEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL J N/6-11 DEV. CENTER, WA SHEET 1M18R JOB NO. REMOVAL7 6/18 DOWN 1 SAR-1 36x12 1250 CFM (TYP 12) ® g%i i ■ V/ 111111111111111111111 1 0 0 D CEILING DIFFU 1'0 NECK 1200 P 2) MAN BAR ■o, SOUND L INSULATE DUCTWOR 1 ED & SUPPLY 12 6 viu 1 ■ J+J #1603 CEILING DIFF 120 NECK 800 CFM OSA CHASE "r m iga 4 ��41A _21 ��. 0 med /641 /:/ 1 Vr r ♦rsjrr,.vr�r� AoreArr iii►iii war A' A4% dmidnui rd11M24 4420- At' 411, 1 100 16 10 2.6" S.P. 18 8 N HECK - TH-212-30 :10 CFM "WC, 2HP MOTOR 11 1M24 4420-M6 24/8 24/8 45/20 1 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila !"3UILDING DIVISION FOR ADD'L HVAC INFORMATION THIS AREA SEE DWGS 1M24A & 1M24B 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGE D GE\PAL NOTES EFE E\CE NAWI\GS FOR EXHAUST PLAN THIS AREA SEE DRAWING 9-101-1M24C 'ENOVAL \OTES REMOVE (E) AIR HANDLING UNIT, SUPPORTS & APPURTENANCES. REMOVE (E) DUCTWORK, GRILLES, DIFFUSERS, SUPPORTS, INSULATION, AND APPURTENANCES. CAP (E) 15X12 DUCT. MI3-ft 1617 RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 8' 4' 0 4' Fax 206.267.1 701 N I. KEY PLAN SCALE: NONE SAZAN #364-1306 16' SCALE: 1/8"= SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN K.BUN C.HARRAH 11.11.97 RELOCATED HK VAC TO DWG. 1M374 S.RUDELL 03.14.08 A CABINET & CABLE SHOP RELOC. 18040606 HARR RWS 11/03/08 B ADC HVAC UPGRADE 21406–W01969369 SAZAN/FPW 10.25.13 Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE CHECKED C.HARRAH SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION 21406-W01969369 SYMBOL 3 DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL.J-N/11-15 DEV. CENTER, WA SHEET 1 M24R JOB NO. COMP NO. DWG NO. 09-101-1 M24R -V T 1M10 1M11 1M12 1M13 1M14 1M15 —H 1M16 1M17 1M18 1M19 1M20 1M21 1M22 1M23 M224/ 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 1M34 1M35 1M36 1M37 1M38 1M39 1M40 1M41 1M42 1M43 1044 1M45 1M46 KEY PLAN SCALE: NONE SAZAN #364-1306 16' SCALE: 1/8"= SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN K.BUN C.HARRAH 11.11.97 RELOCATED HK VAC TO DWG. 1M374 S.RUDELL 03.14.08 A CABINET & CABLE SHOP RELOC. 18040606 HARR RWS 11/03/08 B ADC HVAC UPGRADE 21406–W01969369 SAZAN/FPW 10.25.13 Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE CHECKED C.HARRAH SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION 21406-W01969369 SYMBOL 3 DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL.J-N/11-15 DEV. CENTER, WA SHEET 1 M24R JOB NO. COMP NO. DWG NO. 09-101-1 M24R IT (1) U OC cn U U U 2" PARTIAL PLA\ VIEW SCALE: 1/8"=1' 0" (HWS CHWHWR U U 1/2" 0 0 0 0_42 1 "CHWR&S REMOVAE REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGEND - HPC HPS - STM HWS - HWR CHWR CHWS COND — P COND CLWS - CLWR GE\PAL CONDENSATE STEAM (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STEAM SUPPLY HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE PUMPED CONDENSATE COOLING WATER SUPPLY COOLING WATER RETURN \OTES EFE \CE . AW I \GS REMOVAL \OTES REMOVE (E) CHWS&R PIPING CONNECTED TO ACU -1 AND CAP. REMOVE (E) CONDENSATE DRAIN PIPING FROM ACU -1 COOLING COIL AND DOWN TO THE TERMINATION POINT. 14113-1c/7 RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER 00 00 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 • r 'TSV T T T 1M60 1M61 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 1M20 1M21 1M72 1M73 /1M744 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 1M84 1M85 1M86 1M87 1M88 1M89 1M90 1M91 1M92 1M93 1M94 1M95 1M96 KEY PLAN SCALE: NONE 4 SCALE: 1/8"=1'- SYM /8"=1'- 8' 16' SYM REVISION BY APPROVED DATE SYM REVISION .BY APPROVED DATE REDRAWN KB/CH 9.9.99 A ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE HVAC PIPING PLAN CURRENT REVISION 21406-W01969369 SYMBOL A DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/11-15 DEV. CENTER, WA SHEET 1 M74R JOB NO. COMP NO. DWG NO. 09-101-1M74R DUPL X ACUUM DROP S E 6"VAC U 11 A -SAN T. CONNECT DRAIN UP TO LOW --B.U.CT_ABOVE.- MATCH LINE -SEE DWG 9-101-1M112 11 VAC 1 1/2" Q EL 33-09' VAC arc VAC N Ver. 1/2"A 3/4"W 2" AIR DN. (8) QUICK AIR OUTLETS 3/"DUPLEX Y"A AIR DROP 1 1 2". STORM P -TRAP VAC UTILITY STAND 11 1M118 M605 VAC If (2 1M118 M603 VAC) OVA 1/2" I ' 1 VAr 1 1/2" FOR MEZZ OFFICE, EL 35.17' SEE SHEET 4535-M2 VAC 0, cD L LJ w MATCH LINE - ��f 0 0 0 0 0 SAN DI 1/2" POC 1 1/2" 40 U X U 11 (4) QUICK AIR OUTLETS RPBA, SEE 1M118 x %" PARKER EZ306M-6T (TYP. OF 7 DUPLEX AIR DROPS) 3/4"PWan al - 3/4"CW M603 CU 1, VAC U 34" 3411 Y2" 2 U U 1/2"A Y2"CAP 1-1 /2"PW 1" (E)4"SAN RISER 1-1/2"SAN DN TO AIR GAP FITTING FOR TYPICAL FLUME PENETRATION DETAIL, SEE 1 M1 M605 3/4"A T ROUTER CONTROL PANEL, OR CONNECTION DETAIL, jEE (\\ 1 M11.31 M604 VAC 6 M60'1 3/4"CW 1-1/2"A 1-1/2 1/2"A 11 1/2"A PW SAN SAN FC0 o 1 1M118 M603 A 3 411 v6w DOWN TO PEPSI SYRUPS RACK 3/4"CW CL EL 33-09' VACC DE -IONIZED WATER STATION A 4" SAN 3/4"DN TO MEN RM VAC CW 3/4" DRAIN FROM DRIP PAN ON TOP OF CAP. RUN DOWN INSIDE WALL AND STUB INTO SERVICE SINK BELOW. - 0 0 0 1M118 4535-M2 x A 1M118 4535-M2 >: 0 t' X 3/4" -f{1NNEL DRAIN -© 8 -0" AFF 0 0 1/2" DN IN WALL ALL CA & VAC BRANCES Y2' UNLESS OT-IERWISE VOTED Y"DUPLEX SERVICE SINK VAC 411 4" PVC SCH-40, PEPSI SYRUPS VAC 6"VAC 1/2" THRU WALL W STOP VALVE. EL 34.50' 2'10 STEAM VENT FROM PLATEN PRESS 1/2" P AN U .' 1'T ELBOW ON TOP OF CAP SEE 1M18EXH 11 Y4"DUPLEX 1, 1 ° r/ ,/A�.I"Wv 411P Ord omr gi 1/2" I� BELOW CEILING STUB OUT 18"AFF --T€RMINATE W/ BALL VALVE (4 TYP) Y2"CW DN TO THREE HOLE POLISHER, RELOC. TO ROUGH PREP. STUB OUT W/ VALVE © POLISHED AS PER DETAIL U a 3/4" 1M118 4535-M2 �Y» C 2 Q /" y"DUPLEX 1M118 4535 a 2 1-o 1M118 5 1 /2"CW&HW DN IN WALL TO SINK 4535-M2 MATCH LINE - SEE DWG 9-101-1M124 Y' EL 34.50' AY" VAC ,1 » W C v12 I I -I Y1 )/2" 1-1 VAC A Y2» r 1M113 4535-M2 EL 34.50' EL 34.50' 1M118 4535-M2 EL 34.50' REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGEND GE\E AL OYES COMPRESSED AIR PIPE: TYPE L COPPER, ASTM B88. COMPRESSED AIR FITTINGS: PROPRESS OR SWEAT SOLDER SOCKET. AIR AND VACUUM PIPING ABOVE ROOM ALONG COLUMN LINE "M" DRAWN PER 4420 M2. BRANCHES ARE GENERALLY ABANDONED UNLESS AN AIR OR VACUUM OUTLET SYMBOL IS SHOWN. PROCESS VACUUM PIPING SYSTEMS: INSTALLATION OF PROCESS VACUUM PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH FACILITIES MECHANICAL STANDARD D38106-20 USING THE FOLLOWING DEVELOPMENTAL CENTER SITE-SPECIFIC PREFERENCES: PIPE: ASTM B-88 SEAMLESS COPPER, TYPE L, HARD DRAWN. FITTINGS: 2" AND SMALLER: WROUGHT OR CAST COPPER SOLDERED OR PROPRESS SOCKET FITTINGS. BRAZED JOINTS BELOW GROUND. 2-1/2" OR LARGER: TYPE L COPPER ROLL -GROOVED FITTINGS AND DUCTILE IRON ROLL -GROOVED COUPLINGS WITH EPDM GASKETS, RIGID SYSTEM. VALVES: 2" AND SMALLER: BRONZE TWO-PIECE BALL VALVE, THREADED END. APOLLO 70-100. PROVIDE WITH THREADED ADAPTER FITTINGS. 2-1/2" AND LARGER: ELASTOMER -LINED LUGGED BUTTERFLY VALVE. FURNISH WITH 125# COPPER FLANGE ADAPTERS. DEMCO 211xx TESTING OF NEW PROCESS VACUUM PIPING SHALL USE COMPRESSED AIR OR NITROGEN AT 150 PSIG FOR 1 HOUR. THERE SHALL BE NO LOSS IN PRESSURE. CHECK EACH JOINT WITH SOAPY WATER. BALL VALVE APOLLO 70-100. REFERE\CE DRAWI\GS 109-101-4420 M2 VOVAL NOTES REMOVE (E) SINK, DRAIN, PUMP AND ALL UTILITIES. CAP CW AND HW AT STOP VALVES. REMOVE 3/4" DRAIN DOWN TO PUMP. REMOVE PUMP AND DISCHARGE PIPING OUT TO TERMINATION. REMOVE THE DUPLEX VACUUM AIR DROPS AND PIPING BACK TO THE MAIN ABOVE THE CEILING AND CAP. REMOVE VAC PIPING BACK TO MAIN AND CAP. REMOVE THE DUPLEX COMPRESSED AIR DROPS AND PIPING BACK TO THE MAIN AND CAP. REMOVE (E) LOW POINT DRAIN - SEE DRAWING 1M18 . MIS 197 RECEIVED CITY''` OF TUKWILA 0C 2 9 2013 A D E H J Ja PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 REMOVAL ( / V T T T 1M110 1M111 1M112 1M113 1M114 1M115 1M116 1M117 ',1M11 8" W 1M119 1M120 1M121 1M122 1M123 1M124 1M125 1M126 1M127 -H 1M128 1M129 1M130 1M131 1M132 1M133 1M134 1M135 1M136 1M137 1M138 1M139 1M140 1M140 1M142 1M143 1M144 1M145 1M146 9-101.1 KEY PLAN SCALE: N.T.S. N 4' 0 4 SCALE: 1/8"=1'-0" 11 16' SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB CH E DESIGN 4045 ITERIM SHOP 8681317 M.WONG RWS 03.20.09 A B C D CONSOLIDATE QA LAB DRIP PAN AND DRAIN HFE COND DRAIN FOR RELOC FREEZER CABINET & CABLE SHOP RELOC. J#190106-06 1001293943 14079508 18040606 CH RWS HARR HARR RWS 11.7.00 10.06.04 06/29/05 10/28/08 F DESIGN COMPRESSED AIR DROP G RELOCATE (5) AIR DROPS 9735814 10559452 H J ADC ADC HVAC UPGRADE 21406-W01969369 M.WONG M.WONG WH SAZAN/FPW MW FOR RWS RWS LEG 10.20.09 04.06.10 04.01.13 10.25.13 i___AwAsrEw.e.dew° Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE PLUMBING PLAN CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/6-11 DEV. CENTER, WA SHEET IMII8R JOB NO. 190106-06 COMP NO. DWG NO. SECURITY BAR, SEE DWG. 83-BMAC-1 120 1/8 x 50 1/2 FILTER SECTION 64/24 ABOVE FROM AHU #11 64/24 BELOW FROM AHU #9 1/40 M CO AIR EXTRACTOR (TYP.) 22/14 20" NECK DIFFUSER 1425 CFM, TYPICAL (8) PLACES 22/14 26/14 f N J/ SSE DWG 109-101-4553-M5 FOR DUCTWORK FEEDING MEZZANINE OFFICE AREA 10x10 DIFF 321CFM 80 /9x9 DIFF 291CFM 15x15 RETURN 643CFM 80 35/23 15x15 RETURN 875CFM VCBC-20 1750 CFM 9x9 DIFF 291CFM 80 80 80 SEE DET. 15/12 9x9 DIFF 291CFM x x x /12 BELOW 80 15x15 RETURN 875CFM (8) 24x12 GRILLES ® 1500 CFM EA. 1M18 SPIIEETER 3(7.5' 9x9 DIFF 291CFM 18'-0" 9x9 DIFF 291CFM /9x9 DIFF 291CFM DUCT 8'-0" TURNING VANE 22/14 `(I 78/24 (2) 36x18 GRILLES CO 1800 CFM EA. EL. 20'-6" B.O. DUCT HUMIDIFIER 16'-0" x 1M18 M601 1M 18/12 18 4559—M3 � 1 Aft 20000 CFM IC1 I 18/18 WALL TRANSFER FAN NOM 225 CFM MAN -BARRED 0 0 0 0 \ X 0 0 0 12x12 GRILLE SOUND BAFFLE ENCLOSURE FOR CONST. DETAILS SEE SKETCH NO. 35D0832086 42" X 38" RAG -11020 CFM EXHAUST DUCT/ FROM EFO1 L12A 8/12 1 TO ROOF. 140 CV -19 RA 100 CFN 0 0 0 180 16/18 140 180 SAR-1, 36/12 1250 CFM (4) TYP. x X x UP 0x 0 0 20"0 22 GA GALV. 60 LONGITUDINAL WELDED SEAM DUCT WORK 48x24 RA GRILLE 2200 CFM MAN BARRED AHU #27 (REF ABOVE) 80 80 20/16 REVIEWED FOR CODE COMPLIANCE APPROVED 10 22/16 RA-- 36/18 UP, SEE DWG. 109-101-4565-M1 APR 0 3 2014 City of Tukwila ILDING DIVISION 9 LEGE GE\E \D AL \OTES FILTERS INSIDE AIR HANDLERS: 2" 3M MERV 12 MINI -PLEAT. NO BAG FILTERS ARE USED; BAG FILTER HOUSINGS ARE ABANDONED m• . PERFORM ALL SHEETMETAL WORK IN ACCORDANCE WITH CURRENT SMACNA STANDARDS. DUCT SEALING AND DUCT INSULATION SHALL MEET REQUIREMENTS LISTED IN CHAPTER 6 OF INTERNATIONAL MECHANICAL CODE AND WASHINGTON STATE ENERGY CODE. CONSTRUCT DUCTS WITH G-60 OR BETTER GALVANIZED STEEL (ASTM 527) LFQ, CHEM TREAT. CONSTRUCT RECTANGULAR DUCTWORK TO MEET ALL FUNCTIONAL CRITERIA DEFINED IN CHAPTER 11, OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS (HDCS). PROVIDE DIAGONAL CREASING OR BEADING ON ALL PANELS WIDER THAN 18 -INCHES, AND PANELS LESS THAN 18 GAUGE. CONSTRUCT ROUND AND FLAT OVAL DUCTWORK IN ACCORDANCE WITH CHAPTER 3 OF SMACNA HDCS. DUCTMATE, METZ, OR W.D.C.I. DUCT CONNECTION SYSTEMS ARE ACCEPTABLE. DUCTS CONSTRUCTED USING THESE SYSTEMS WILL REFER TO THE MANUFACTURER'S GUIDELINES FOR SHEET GAUGE, INTERMEDIATE REINFORCEMENT SIZE AND SPACING, AND JOINT REINFORCEMENTS. SPIN -IN FITTINGS SHALL BE CONICAL TYPE WITH VOLUME DAMPER, AND QUADRANT; FLEX MASTER, ELGEN OR EQUIVALENT. ELBOWS IN RECTANGULAR OR SQUARE DUCTWORK SHALL HAVE AN INSIDE RADIUS EQUAL TO DIMENSION OF ELBOW IN THE PLANE OF THE TURN; OTHERWISE USE RADIUSED ELBOWS WITH SPLITTER VANES OR SQUARE THROAT ELBOWS WITH TURNING VANES. 9. ELBOWS IN ROUND AND FLAT OVAL DUCTWORK SHALL HAVE THE INSIDE RADIUS EQUAL TO DIMENSION OF ELBOW IN THE PLANE OF THE TURN. USE SEGMENTED, SEGMENTED STANDING SEAM, PLEATED, OR STAMPED ELBOWS. ADJUSTABLE ELBOWS ARE NOT ALLOWED. 10. SQUARE CORNER INSERTS (TURNING VANES) SHALL BE SMACNA FIG. 4-3 DOUBLE THICKNESS, RUNNER TYPE 2 WITH 2 -1/8 -INCH SPACING. 11. VOLUME DAMPERS: INCLUDE A DAMPER IN THE DUCT TO EACH SUPPLY, EXHAUST, OR RETURN OPENING; ALSO IN EACH BRANCH DUCT WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH. LOCATE DAMPERS AT A POINT WHERE THE DUCT IS ACCESSIBLE; AS FAR FROM THE OUTLET AS POSSIBLE. DAMPERS SHALL BE RUSKIN MD25 OR MDRS25. 12. THOROUGHLY CLEAN ALL DEBRIS FROM THE INSIDE OF ALL DUCTWORK AND PLENUMS. BLOW FREE ALL SMALL PARTICLES OF RUBBISH AND DUST. 13. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. AFTER SHOP DRAWINGS ARE COMPLETED VERIFY EXACT LOCATION OF GRILLES AND DIFFUSERS IN THE FIELD. ENSURE THAT DIFFUSER AND GRILLE FRAMES MATCH CEILING TYPES AND FINISH PRIOR TO ORDERING. 14. SIZES SHOWN ARE NET, CLEAR INSIDE DUCT DIMENSION. CO \S-RUCTIO\ OYES PROVIDE (N) SUPPLY AIR GRILLES (TYP 4). PROVIDE (N) SUPPLY AIR DUCT. POC OF (N) RETURN AIR DUCT TO (E) RETURN AIR GRILLE. PROVIDE 1/2 AP ARMAFLEX DUCT LINER FOR ALL SUPPLY DUCTWORK. PROVIDE 1/2" AP ARMAFLEX DUCT LINER IN EXHAUST DUCTWO'K FOR FIRST 5' FID OM AHU. ML3 icn 21406-WO1969369 ISSUED FOR CONSTRUCTION 10.25.13 1.7 O ©W 0 ED W Li RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 9Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 4► t! 1M10 1M11 1M12 1M13 1M14 1M15 1M16 1M17 �/�j 1M19 1M20 1M21 —H 1M22 1M23 1M24 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 1M34 1M35 1M36 1M37 1M38 --H ri 1M39 1M40 1M41 1M42 1M43 1044 1M45 1M46 KEY PLAN SCALE: NONE 0 4' 16' SCALE: 1/8"= 1 '-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE K ADC HVAC UPGRADE 21406-W01969369 SAZAN/FPW 10.25.13 F RELOCATE TEST EQUIPMENT 190106-18 KGP 11/20/00 G ADD 2 SUPPLY GRILLES COL. K-10.5 57639900 HARR RWS 10/09/07 C ADD EXHAUST SYSTEM 74747901 SPR 7/28/95 RELOCATED HK VAC TO DWG. 1M368 S.RUDELL 03.19.08 D E AS BUILD VACATE ESS 74747901 7180376 SPR HARRAH 2/5/96 H CABINET & CABLE SHOP RELOC. 18040606 5/3/99 J REFURBISH AHU#9 - ADC 400K CLEANROOM 11305389 HARR HARR RWS RWS 11/04/08 03/30/11 Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DUARTE DATE 2/11/94 CHECKED SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION 21406-W01969369 SYMBOL I / DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/6-11 DEV. CENTER, WA SHEET 1M18 JOB NO. 21406-W01969369 COMP NO. DWG NO. 09-101-1M18 36/18 DOWN OA O 03 66/24 0 -SAR-1 36x12 1250 CFM (TYP 12) N N i EFERE\CE DRAWINGS FOR EXHAUST PLAN THIS AREA SEE DRAWING 9-101-1M24C GENERAL \OTES (co\T.) 13. SIZES SHOWN ARE NET, CLEAR INSIDE DUCT DIMENSION. 1 CD -1 12X12 400 CFM CD -1 12X12 VD 400 CFM 12 6 M24 M622 EnVD 100 RG -1 14008 CF I RG -1 18X18 840 CFM CD -1 Vu 12X12 400 CFM CD -1 12X12 400 CFM 0 N3 16/10 CD -1 12X12 520 CFM CD -1 12X12 520 CF 2 r) 20/10 24/24 8 OSA CHASE 4 48X14 00 1M24 4420-M6 CONTROL PANEL (REF.) PARTIAL PLA\ VIEW SCALE: 1/8"= 1 '-o" D.I. BOTTLE CABINET (REF.) M622 1M24 4420-M6 18/8 24/8 } 45/20 10 CONSTRUCTION NOTES PROVIDE (N) AIR HANDLING UNIT. POC OF (N) OUTSIDE AIR DUCT TO (E) OUTSIDE AIR DROP FROM ROOF. PROVIDE (N) SUPPLY AIR DIFFUSERS (TYP 6). PROVIDE SHEET -METAL BLANK -OFF PANEL OVER (E) 48X24 WALL GRILLE. PAINT TO MATCH WALL COLOR. CAP (E) 15X12 BRANCH DUCT. PROVIDE (N) RETURN AIR DUCT. CONNECT TO AHU 2N13. PROVIDE (N) RETURN AIR GRILLE AND BRANCH DUCT. PROVIDE 1/2" AP ARMAFLEX DUCT LINER. PROVIDE VARIABLE FREQUENCY DRIVES FOR AH2N13 WITH UNISTRUT CHANNEL FRAME MOUNTED TO PLATFORM. SEE ELECTRICAL PLAN FOR VFD. PROVIDE (N) ROOM TEMPERATURE SENSOR CONNECTED TO AH2N13. SEE DRAWING M318, AIR HANDLING UNIT PROVIDE DUCT MOUNTED SMOKE DETECTOR. SEE ELECTRICAL PLANS FOR WIRING TO AHU. REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION FOR ADD'L HVAC INFORMATION THIS AREA SEE DWGS 1M24A & 1M24B 13 21406-W01969369 DPD REVIEW 03.17.14 LEGEND GE\ ERAL NOTES 1. PERFORM ALL SHEETMETAL WORK IN ACCORDANCE WITH CURRENT SMACNA STANDARDS. DUCT SEALING AND DUCT INSULATION SHALL MEET REQUIREMENTS LISTED IN CHAPTER 6 OF INTERNATIONAL MECHANICAL CODE AND WASHINGTON STATE ENERGY CODE. CONSTRUCT DUCTS WITH G-60 OR BETTER GALVANIZED STEEL (ASTM 527) LFQ, CHEM TREAT. CONSTRUCT RECTANGULAR DUCTWORK TO MEET ALL FUNCTIONAL CRITERIA DEFINED IN CHAPTER 11, OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS (HDCS). PROVIDE DIAGONAL CREASING OR BEADING ON ALL PANELS WIDER THAN 18 -INCHES, AND PANELS LESS THAN 18 GAUGE. CONSTRUCT ROUND AND FLAT OVAL DUCTWORK IN ACCORDANCE WITH CHAPTER 3 OF SMACNA HDCS. DUCTMATE, METZ, OR W.D.C.I. DUCT CONNECTION SYSTEMS ARE ACCEPTABLE. DUCTS CONSTRUCTED USING THESE SYSTEMS WILL REFER TO THE MANUFACTURER'S GUIDELINES FOR SHEET GAUGE, INTERMEDIATE REINFORCEMENT SIZE AND SPACING, AND JOINT REINFORCEMENTS. SPIN -IN FITTINGS SHALL BE CONICAL TYPE WITH VOLUME DAMPER, AND QUADRANT; FLEX MASTER, ELGEN OR EQUIVALENT. ELBOWS IN RECTANGULAR OR SQUARE DUCTWORK SHALL HAVE AN INSIDE RADIUS EQUAL TO DIMENSION OF ELBOW IN THE PLANE OF THE TURN; OTHERWISE USE RADIUSED ELBOWS WITH SPLITTER VANES OR SQUARE THROAT ELBOWS WITH TURNING VANES. ELBOWS IN ROUND AND FLAT OVAL DUCTWORK SHALL HAVE THE INSIDE RADIUS EQUAL TO DIMENSION OF ELBOW IN THE PLANE OF THE TURN. USE SEGMENTED, SEGMENTED STANDING SEAM, PLEATED, OR STAMPED ELBOWS. ADJUSTABLE ELBOWS ARE NOT ALLOWED. SQUARE CORNER INSERTS (TURNING VANES) SHALL BE SMACNA FIG. 4-3 DOUBLE THICKNESS, RUNNER TYPE 2 WITH 2 -1/8 -INCH SPACING. 10. VOLUME DAMPERS: INCLUDE A DAMPER IN THE DUCT TO EACH SUPPLY, EXHAUST, OR RETURN OPENING; ALSO IN EACH BRANCH DUCT WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH. LOCATE DAMPERS AT A POINT WHERE THE DUCT IS ACCESSIBLE; AS FAR FROM THE OUTLET AS POSSIBLE. DAMPERS SHALL BE RUSKIN MD25 OR MDRS25. 11. THOROUGHLY CLEAN ALL DEBRIS FROM THE INSIDE OF ALL DUCTWORK AND PLENUMS. BLOW FREE ALL SMALL PARTICLES OF RUBBISH AND DUST. 12. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. AFTER SHOP DRAWINGS ARE COMPLETED VERIFY EXACT LOCATION OF GRILLES AND DIFFUSERS IN THE FIELD. ENSURE THAT DIFFUSER AND GRILLE FRAMES MATCH CEILING TYPES AND FINISH PRIOR TO ORDERING. 197 RECEIVED CITY OF TUKWILA MAR 282014 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 41" Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 r / W T T T T 1M10 1M11 1M12 1M13 1M14 1M15 1M16 1M17 1M18 1M19 1M20 1M21 1M22 1M23 1M24/ ii/ 1M25 1M26 1M27 1M28 1M29 1M30 1M31 1M32 1M33 —1 1M34 1M35 1M36 1M37 1M38 [I 1M39 1M40 1M41 1M42 1M43 44.4 1M45 1M46 _J 8' KEY PLAN SCALE: NONE 4' 4' 8' 11 16' SCALE: 1/8"=1' -0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN K.BUN C.HARRAH 11.11.97 RELOCATED HK VAC TO DWG. 1M374 CABINET & CABLE SHOP RELOC. 18040606 B ADC HVAC UPGRADE 21406-W01969369 C ADC HVAC UPGRADE DPD REVIEW 21406-W01969369 S.RUDELL HARR SAZAN/FPW SAZAN/DJ RWS 03.14.08 11/03/08 10.25.13 03.17.14 Q�BOE/A/O° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE CHECKED C. HARRAH SUBTITLE HVAC DUCTWORK PLAN CURRENT REVISION 21406-W01969369 SYMBOL C DATE 03.17.14 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL.J-N/11-15 DEV. CENTER, WA SHEET 1 M24 JOB NO. COMP NO. DWG NO. 09-101-1M24 0 U x N U 1 1/2" 2" 2" 150# CC U CHILLER HWS CHWS HWR-11 CHWR 0_ ,1 l 65 "OOLI 1 1/2"-- 6665 /2'= 1M68 M601 CHWS 1 -FC I CHWS CHWR CHWR CHWS CHWR CHWS EL 16'—J" AFF EL 18-0" AFF CHWR 1 1/4"--s HUMIDIFIER N U 1M601 " 2" 2" 150# 6" CHWS--- HWR HWS HWR —t 2" HWS fi2" HWR 1 "CHWS&R REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION 0 0 0 0 0 0 0 0 0 " (12L10/ 0 0 0 0 0 0 x x x x (11 L10�� 0 0 0 0 0 CHWS CHWR 0 0 AC -3 ❑ 9 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 HPC - HPS - STM - HWS HWR - CHWR - CHWS COND — P COND CLWS - CLWR LEGE \D CONDENSATE STEAM (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STEAM SUPPLY HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE PUMPED CONDENSATE COOLING WATER SUPPLY COOLING WATER RETURN GE\PAL NOTES INSULATE ALL PIPING AND ASSOCIATED FITTINGS PER WASHINGTON STATE ENERGY CODE. 2. INSULATE ALL HOT AND COLD WATER PIPING WITH GLASS FIBER INSULATION WITH ALL SERVICE JACKET. USE HEAT BONDING TAPE TO CLOSE INSULATION. STAPLES AND PRESSURE TAPE ARE PROHIBITED. CHILLED WATER AND HEATING HOT WATER PIPING SHALL BE BLACK STEEL, ASTM A53, GRADE B ERW, SCHEDULE 40 PIPE WITH CLASS 150 MALLEABLE IRON, THREADED FITTINGS, ASTM A 197, ANSI B16.3 OR TYPE L HARD DRAWN COPPER PIPE, ASTM B88, WITH WROT COPPER SOLDER JOINT FITTINGS AND UNIONS, 95-5 TIN/ANTIMONY SOLDER OR CLASS 125 CAST -BRONZE SOLDER JOINT FLANGES, FLAT FACED, ASTM B584, FULL. FACE GASKETS AND CARBON STEEL HEX HEAD MACHINE BOLTS AND HEX NUTS, ASTM A 307 GRADE B. EFEK \CE DAWI GS TIFF 109-101-4535-M3 FIRST FLOOR PIPING POC OF (N) 1 " HWS/R TO (E) 2" HWS/R MAIN. PROVIDE (N) HWS/R PIPING AND CONNECT TO AH2N13. M13 RECEIVED CITY OF TUKWILA OCT Z 9 2013 PERMIT CENTER SAZAN '97 ' / WT T T T_I 1M60 1M61 1M62 1M63 1M64 1M65 1M66 1M67���/�� 1M69 1M70 1M71 1M72 1M73 1M74 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 1M84 1M85 1M86 1M87 1M88 ri 1M89 1M90 1M91 1M92 1M93 1M94 1M95 1M96 GROUP KEY PLAN 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SCALE: NONE 11 16' MN SCALE: 1/8"=1'- 3 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB/CH A RELOCATE TEST EQUIPMENT J#190106-18 KGP B PUR/INSTALL MODULAR. CLEAN ROOM J#546610-01 C. HARRAH RWS 10.01.04 C REFURBISH AHU #9 — ADC 400K CLEANROOM 11305389 HARR 03/30/11 D ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 Q�BOE/NG° o'— Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED ENCINEER SUBTITLE HVAC PIPING PLAN CURRENT REVISION 21406-W01969369 SYMBOL D DATE 10.25.13 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/6-11 DEV. CENTER, WA SHEET 1 M68 JOB NO. COMP NO. DWG NO. 09-101-1M68 PARTIAL PLA SCALE: 1/8''=1'-0" \ VIEW REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION �113� 197 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGE\D - HPC CONDENSATE STEAM (HIGH PRESSURE) - HPS STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) - STM STEAM SUPPLY HWS HEATING WATER SUPPLY - HWR HEATING WATER RETURN - CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY COND CONDENSATE P COND PUMPED CONDENSATE CLWS COOLING WATER SUPPLY - CLWR COOLING WATER RETURN JE\HAL NOTES INSULATE ALL PIPING AND ASSOCIATED FITTINGS PER WASHINGTON STATE ENERGY CODE. INSULATE ALL HOT AND COLD WATER PIPING WITH GLASS FIBER INSULATION WITH ALL SERVICE JACKET. USE HEAT BONDING TAPE TO CLOSE INSULATION. STAPLES AND PRESSURE TAPE ARE PROHIBITED. CHILLED WATER AND HEATING HOT WATER PIPING: BLACK STEEL, ASTM A53, GRADE B ERW, SCHEDULE 40 PIPE WITH CLASS 150 MALLEABLE IRON, THREADED FITTINGS, ASTM A 197, ANSI B16.3 OR TYPE L HARD DRAWN COPPER PIPE, ASTM B88, WITH WROT COPPER SOLDER JOINT FITTINGS AND UNIONS, 95-5 TIN/ANTIMONY SOLDER OR CLASS 125 CAST -BRONZE SOLDER JOINT FLANGES, FLAT FACED, ASTM 8584, FULL FACE GASKETS AND CARBON STEEL HEX HEAD MACHINE BOLTS AND HEX NUTS, ASTM A 307 GRADE B. 4. D.I. WATER PIPING: 304L STAINLESS STEEL, SCHEDULE 40S, ASTM A312. FITTINGS: FORGED 304L STAINLESS STEEL, CLASS 3000 SOCKET WELD OR SCREWED ASTM A182. ISOLATION VALVE: FULL PORT, STAINLESS STEELBALL VALVE, WATTS S-FBV-1. EFE�E \CE DRAWINGS CO\ST UCTIC OTES POC OF (N) PIPING. PROVIDE (N) AH2N13. 1-1/2" CHWS/R TO (E) 2" CHWS/R HWS/R PIPING AND CONNECT TO PROVIDE HUMIDIFIER CONTROL PANEL. PROVIDE D.I. BOTTLE CABINET. LOCATE UNDER (N) STAIRCASE. CAP (E) CHWS&R. RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 KEY PLAN SCALE: NONE 4' 4' 16' 11111::_—M11----- ------ e SCALE: 1/8"= '-o" SYM REVISION A REDRAWN ADC HVAC UPGRADE 21406—W01969369 BY KB/CH SAZAN/FPW APPROVED DATE SYM REVISION BY APPROVED DATE 9.9.99 10.25.13 BOE/NG° �r- Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE HVAC PIPING PLAN CURRENT REVISION 21406401969369 SYMBOL A DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/11-15 DEV. CENTER, WA SHEET 1M74 JOB NO. COMP NO. DWG NO. 09-101-1 M74 ?- W T 1M60 1M61 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 1M20 1M21 1M72 1M73 j MM774/ A 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 1M84 1M85 1M86 1M87 1M88 [I 1M89 1M90 1M91 1M92 1M93 —� 1 494 1M95 1M96 KEY PLAN SCALE: NONE 4' 4' 16' 11111::_—M11----- ------ e SCALE: 1/8"= '-o" SYM REVISION A REDRAWN ADC HVAC UPGRADE 21406—W01969369 BY KB/CH SAZAN/FPW APPROVED DATE SYM REVISION BY APPROVED DATE 9.9.99 10.25.13 BOE/NG° �r- Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE HVAC PIPING PLAN CURRENT REVISION 21406401969369 SYMBOL A DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/11-15 DEV. CENTER, WA SHEET 1M74 JOB NO. COMP NO. DWG NO. 09-101-1 M74 1/2"A 3/4"W (8) QUICK AIR OUTLETS RPBA, SEE 1M118 M603 2" AIR DN. MATCH LINE /SEE DWG 9-101-1M112 (4) QUICK AIR OUTLETS (E)4"SAN RISER 1 -1/2"SAN DN TO AIR GAP FITTING "DUPLEX Y2"A AIR DROP Q)4® 1 1/2" 2" y,. %" PARKER EZ306M-6T (TYP. OF 7 DUPLEX AIR DROPS) 3/4"PW- a 3/4"CW FOR TYPICAL FLUME PENETRATION DETAIL, SEE 1M1 M605 3/4"A T ROUTER CONTROL PANEL, OR CONNECTION DETAIL, EE 1M118] M604 1 1 2" STORM DUPL X ACUUM DROP S E (TMP) 1M118 M584 VAC 1 1/2" VAC P -TRAP VAC 1M118 M605 VAC 1" 2 1"VAC 3/4"DN 1M11603 VAC CW 1 UTILITY STAND SAN 1-1/2)/AC 112 VAC 1/2"A 1 4" `Tja= VAC tw DOWN TO PEPSI SYRUPS RACK 1M118 M603 A 3 4" 3/4"CW q_ EL 33-09' VAC 6"VAC VAC DE -IONIZED WATER STATION CONNECT DRAIN UP TO LOW POINT OF DUCT ABOVE �--1 /2" FOR MEZZ_� OFFICE, EL 35.1.7, SEE SHEET 4535-M2 1 e4 VAC 6"VAC EL 34.50' 2"0 STEAM VENT FROM PLATEN PRESS VAC--" 1/2" ---VAUc- TO MEN RM 4" PVC SCH-40, PEPSI SYRUPS DRIP PAN UNDER DUCT ELB TOP OF CAP SEE 1M18EXH MATCH LINE - SEE DWG 9-101- 0 1M118 4535-M2 1/2" I N WA ALL BRAN OTHER & VAC ES Y" UNLESS ISE NOTED 0 0 0 1M118 4535-M2 0 0 TYP 7) 1M118 M622 A 3 ft 12L10 A 0 0 0 0 x x x 1 0 BELOW CEILING STUB OUT 18"AFF ' -GERMINATE W/ pme�---- BALL VALVE (4 TYP)3/4", EL 34.50' 1/" A VAC rn CD Cn w w w 1M118 M603 DUPLEX VACUUM DROP, 1M11,8 4535-M2 EL 34.50' 1M1 8535-M2 0 ox x A 3/4" A 0 0 0 N) YAC EAHU-27 ABOVE ONS 4 HARDLID (REF.) 1" 1/2"CW&HW DN I IN WALL TO SINK BELOWCEILING 0 0 1M118 4535-M2 EL 34.50' EL 28.00' NNEL DRAIN -0" AFF 0 1 1M118 4535-M2 EL 34.50' LEGE \D CO\STUCTIO\ COTES CAP (E) CW AND HW AT STOP VALVES ON WALL. POC OF (E) 4" PAN DRAIN TO (N) CONDENSATE PUMP. PROVIDE (N) CONDENSATE PUMP AND ROUTE 1/2" TYPE L COPPER DISCHARGE PIPE TO AC CONDENSATE DRAIN PIPE. 3 POC OF (N) 1/2" DRAIN PIPE TO (E) 1" DRAIN. PROVIDE 1" CHECK VALVE (NIBCO S-413) UPSTREAM OF (N) 1/2" BRANCH CONNECTION. POC OF (N) 1/2"A. EXTEND AND CONNECT TO RELOCATED SHEETER. POC OF (N) 3/4"CW. EXTEND AND CONNECT TO RELOCATED SHEETER. CAP CW PIPE AT ORIGINAL SHEETER LOCATION. POC OF (N) 1/2 "VAC. EXTEND DOWN TO ROOM. TERMINATE WITH DUPLEX QUICK DISCONNECTS. CAP (E) VAC AT MAIN. CAP (E) COMPRESSED AIR AT MAIN. 1> RELOCATE (E) LOW POINT DRAIN FOR THE COMPRESSED AIR TO OUTSIDE THE CLEAN ROOM. TERMINATE AT 60" AFF. RELOCATE (E) LOW POINT DRAIN FOR THE VACUUM AIR PIPING TO OUTSIDE THE CLEAN ROOM." TERMINATE AT 60" AFF. POC OF (N) 1/2 "A BRANCH CONNECTION. PROVIDE (N) DUPLEX COMPRESSED AIR OUTLET ON THE WALL INSIDE THE ROOM. GE \E SAL NCTES COMPRESSED AIR PIPE: TYPE L COPPER, ASTM B88. COMPRESSED AIR FITTINGS: PROPRESS OR SWEAT SOLDER SOCKET. AIR AND VACUUM PIPING ABOVE ROOM ALONG COLUMN LINE "M" DRAWN PER 4420 M2. BRANCHES ARE GENERALLY ABANDONED UNLESS AN AIR OR VACUUM OUTLET SYMBOL IS SHOWN. PROCESS VACUUM PIPING SYSTEMS: INSTALLATION OF PROCESS VACUUM PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH FACILITIES MECHANICAL STANDARD D38106-20 USING THE FOLLOWING DEVELOPMENTAL CENTER SITE-SPECIFIC PREFERENCES: PIPE: ASTM B-88 SEAMLESS COPPER, TYPE L, HARD DRAWN. FITTINGS: 2" AND SMALLER: WROUGHT OR CAST COPPER SOLDERED OR PROPRESS SOCKET FITTINGS. BRAZED JOINTS BELOW GROUND. 2-1/2" OR LARGER: TYPE L COPPER ROLL -GROOVED FITTINGS AND DUCTILE IRON ROLL -GROOVED COUPLINGS WITH EPDM GASKETS, RIGID SYSTEM. VALVES: 2" AND SMALLER: BRONZE TWO-PIECE BALL VALVE, THREADED END. APOLLO 70-100. PROVIDE WITH THREADED ADAPTER FITTINGS. 2-1/2" AND LARGER: ELASTOMER -LINED LUGGED BUTTERFLY VALVE. FURNISH WITH 125# COPPER FLANGE ADAPTERS. DEMCO 211 xx. QUICK DISCONNECT: Cv=1.3, 3/8" BODY, 1/2" MALE NPT CONNECTION WITH DOUBLE ENDED SHUT OFF. SWAGELOCK, B-QC8-D-8PMVT. TESTING OF NEW PROCESS VACUUM PIPING SHALL USE COMPRESSED AIR OR NITROGEN AT 150 PSIG FOR 1 HOUR. THERE SHALL BE NO LOSS IN PRESSURE. CHECK EACH JOINT WITH SOAPY WATER. BALL VALVE APOLLO 70-100. 6 > LITTLE GIANT MODEL: VCMA-15UL, 1/50 HP, 115V/60/1, 50 GPH © 5'. 0. 9 MATCH LINE - SEE DWG 9-101-1M PATTIAL PLA\ SCALE: 1/8"=1'-0" VIEW X11 1M118 4535-M2 RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION .EFE�E\CE DV\WI 109-101-4420 M2 fr113 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 •Tel 206.267.1700 Fax 206.267.1701 "S i97 9SCALE-10S.1 KEY PLAN 4 0 SCALE: 1 /8"= 4' 0" 11 16' SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB CH E DESIGN 4045 ITERIM SHOP 8681317 M.WONG RWS 03.20.09 A B C D CONSOLIDATE QA LAB DRIP PAN AND DRAIN HFE COND DRAIN FOR RELOC FREEZER CABINET & CABLE SHOP RELOC. J#190106-06 1001293943 14079508 18040606 CH RWS HARR HARR RWS 11.7.00 10.06.04 06/29/05 10/28/08 F G H J DESIGN COMPRESSED AIR DROP RELOCATE (5) AIR DROPS ADC ADC HVAC UPGRADE 9735814 10559452 21406-W01969369 M.WONG M.WONG WH SAZAN/FPW MW FOR RWS RWS LEG 10.20.09 04.06.10 04.01.13 10.25.13 Q�BOE/NC° Expires: 06/29/14 ACCEPTABI LITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE PLUMBING PLAN CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/6-11 DEV. CENTER, WA SHEET 1M118 JOB NO. 190106-06 COMP NO. DWG NO. 09-101-1M118 ?- T T T T 1M110 1M111 1M112 1M113 1M114 1M115 —' 1M116 1M117 j/// /1M118/ �//� 1M119 1M120 1M121 1M122 1M123 1M124 1M125 1M126 1M127 -H --1 1M128 1M1291M130 1M131 1M132 1M133 1M134 1M135 1M136 1M137 1M138 1M139 1M140 1M140 1M142 1M143 1M144 1M145 1M146 --� 9SCALE-10S.1 KEY PLAN 4 0 SCALE: 1 /8"= 4' 0" 11 16' SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB CH E DESIGN 4045 ITERIM SHOP 8681317 M.WONG RWS 03.20.09 A B C D CONSOLIDATE QA LAB DRIP PAN AND DRAIN HFE COND DRAIN FOR RELOC FREEZER CABINET & CABLE SHOP RELOC. J#190106-06 1001293943 14079508 18040606 CH RWS HARR HARR RWS 11.7.00 10.06.04 06/29/05 10/28/08 F G H J DESIGN COMPRESSED AIR DROP RELOCATE (5) AIR DROPS ADC ADC HVAC UPGRADE 9735814 10559452 21406-W01969369 M.WONG M.WONG WH SAZAN/FPW MW FOR RWS RWS LEG 10.20.09 04.06.10 04.01.13 10.25.13 Q�BOE/NC° Expires: 06/29/14 ACCEPTABI LITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE PLUMBING PLAN CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/6-11 DEV. CENTER, WA SHEET 1M118 JOB NO. 190106-06 COMP NO. DWG NO. 09-101-1M118 021 \ / 1 /2"A D SEE DETAIL 6, (3 PLACES 1M121 -14525—M2 1/2" 171 1/2" A IT! T1/2" -cc 1 2 A SAN D< BLASTER EYE WAJM CW J I 0 Q J 0 Z B 14'-0" A 1 1/4"A DN TO 8'-1"AFF 3/4 A GROES D SAW ST 16 GAL" PORTABLE EYE WASH " 1-1/2" STERNVDIT ONE COLLECTOR SYSTEM 5 HP 480V3PN_„ U SONVENT ONE COLLECTOR SYSTEM 5x55 HP 1 [L a6ov. 3 QI U 1M124 4546—M1 FD UTILITY SINK 24X36X14 1/2" HW & CW TO FOOT VALVE FOR SINK SINK 1 1/4"CW UNDER FLOOR Z 0 \/ /. HOT WATER HEATER A.O.SMITH MODEL ELJF50, 4500WATTS 1 1/4" 1/2" 1" INTERCEPTOR 15Wx 18Lx 15D 1 1/4"- VAC—J--1-'4" EMERGENCY EYEWASH EL 34.83' SEE DETAIL 1M124 (5 PLACES) n 4525—M3 EL SS EMERGENCY EYEWASH 1/2" 1711 N 1/2" A 171 I_ 3/4"COPPER\, TO 2ND FLOOR f 1 1 NI 1111111111111111" War Z /NIIITUII4M. Arlan, A • 131--1-c -1 U 1/2"A 1/2" 74:1- N) BELOW FLR. EL 33.83 0 �1 1 U a0 SURFACE GRINDER 1 2" U EL 34.33' SURFACE TREE MIL -RUN ALONG THE EXISTING UNISTRUT MAZAK 3 AXIS MACHINE CENTER ALONG FLOC, W/SLOPED R MP N]d OLE PUN COPPER LINE FROM THIS POINT J J A PRESS SEE DETAIL 1M124 4525 M3 0 Z 0 1 /2" PUMPED D.F. DRAIN TO SINK ® COL M/3 10"0 3 4" I Y"cu cI ALL CA & VAC BRANCHES Y" UNLESS OTHERWISE NOTED — Y"CU "DUPLEX Y"C 2 BELOW CEILING %4"CU 1" VAC DN. TO (3) LAS" VAC DROPS / SNAPTITE VEAC8 P-LERS %"CU n U cI I A CAPS Y" DN IN WALL. CONNECT TO AUCET LF 2 1O)ilNO 1Y" 2 (1) DYNAEQUIP DC2 COUPLER "CU T VAC 1 2"Cl' 3/4" 1/2" DN IN WALL TO FILM PROCESSOR THERMOSTAT MIX 2" DRAIN TO SINK ALONG WALL EL 28 3/4" 10' HW VAC 1/2"A I,1 1"- 1' 2"- �U U 1 1/2" 3/4" 1/2" DN IN WALL TO FILM PROCESSOR THERMOSTATIC MIX VALVE SEE DETAIL J 1 /2' 3/4" HWC Le - CW EL 33.09' EMERGENCY EYE WASH CONTROL PANEL (REF.) VFD'S (REF.) U 1M124 4525—M3 FOR CONTINUATION 1/2" SEE DWG 4420-M2 C UNIT 11i IIIA' 3/4" PW D.I. BOTTLE CABINET (REF.) 1 fl U VAC= -411- 1/2"---11,„ 4r c )I 1c� El Q A— EL 33.09' CW 2" 1/2" DRAIN EL 34.50' q EL 34.50' QIP Q A " „ 2" REVIEWED FOR CODE COMPLIANCE APPROVED PR 0 3 2014 M City of Tukwila BUILDING DIVISION 3 T A - cw D - G HW - PW IWP v RWL - SAN - VAC ict7 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEE\D COMPRESSED AIR DOMESTIC COLD WATER DRAIN GAS DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE PROCESS VACUUM GE\HAL \OTES 1. COMPRESSED AIR PIPE: TYPE L COPPER, ASTM B88. COMPRESSED AIR FITTINGS: PROPRESS OR SWEAT SOLDER SOCKET. 2. AIR AND VACUUM PIPING ABOVE ROOM ALONG COLUMN LINE "M" DRAWN PER 4420 M2. BRANCHES ARE GENERALLY ABANDONED UNLESS AN AIR OR VACUUM OUTLET SY BOL IS SHOW CONDENSATE DRAIN PIPING SHALL BE HARD DRAWN COPPER TUBING, ASTM B88, TYPE L ASSEMBLED WITH WROT COPPER SOLDER JOINTS FITTINGS AND 95-5 TIN/ANTIMONY SOLDER PER ASTM B32 GRADE 50A. INSULATE ALL DRAIN PIPING WITH i" THICK GLASS FIBER INSULATION WITH ALL SERVICE JACKET, ASTM C547. USE HEAT BONDING OR PRESSURE TAPE TO CLOSE INSULATION. STAPLES ARE PROHIBITED. CONDENSATE PUMP: LITTLE GIANT VCMA-15UL, 1/50 HP, 115V/60/1, 50 GPH © 5'. 6 > REDUCED PRESSURE ZONE ASSEMBLY: WATTS MODEL 009. BALL VALVE: NIBCO MODEL S-585-70. EFHE \CE NAWI\GS 109-101-4420 M2 CO\JSTUCTIO\ \OTES PROVIDE (N) 1 INSULATED TYPE L COPPER CONDENSATE DRAIN PIPING. TERMINATE AT (N) CONDENSATE PUMP. SLOPE PIPE AT 1/4" PER FOOT MINIMUM. PROVIDE 3/4" DRAIN CONNECTIONS TO HUMIDIFIER AND DRAIN PAN. PROVIDE (N) CONDENSATE PUMP. POC OF (N) 1/2" PUMPED DRAIN PIPE TO (E) 1/2" PUMPED DRAIN PIPING. PROVIDE TWO (N) CHECK VALVES; NIBCO S-413. PROVIDE (N) 3/4" PW TO (N) D.I. BOTTLE CABINET. CONNECT TO (E) CW. PROVIDE (N) REDUCED PRESSURE DEVICE AND ROUTE DRAIN DOWN TO FUNNEL DRAIN ON FIRST FLOOR. RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER (Al (D) (E) (H)(JIJa) SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 l'/- V T T T T 1M110 1M111 1M112 1M113 1M114 1M115 1M116 1M117 1B/1 1M119 1 IXI E11 1111H1 1M122 011111 /1M120 II X II AMU J / 1M128 1M129 1M130 1M132 1M133 M134 1M135 1M136 1M137 3/4" PW D.I. BOTTLE CABINET (REF.) 1 fl U VAC= -411- 1/2"---11,„ 4r c )I 1c� El Q A— EL 33.09' CW 2" 1/2" DRAIN EL 34.50' q EL 34.50' QIP Q A " „ 2" REVIEWED FOR CODE COMPLIANCE APPROVED PR 0 3 2014 M City of Tukwila BUILDING DIVISION 3 T A - cw D - G HW - PW IWP v RWL - SAN - VAC ict7 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEE\D COMPRESSED AIR DOMESTIC COLD WATER DRAIN GAS DOMESTIC HOT WATER SUPPLY PROCESS WATER INDUSTRIAL WASTE PUMPED VENT RAIN WATER LEADER SANITARY WASTE PROCESS VACUUM GE\HAL \OTES 1. COMPRESSED AIR PIPE: TYPE L COPPER, ASTM B88. COMPRESSED AIR FITTINGS: PROPRESS OR SWEAT SOLDER SOCKET. 2. AIR AND VACUUM PIPING ABOVE ROOM ALONG COLUMN LINE "M" DRAWN PER 4420 M2. BRANCHES ARE GENERALLY ABANDONED UNLESS AN AIR OR VACUUM OUTLET SY BOL IS SHOW CONDENSATE DRAIN PIPING SHALL BE HARD DRAWN COPPER TUBING, ASTM B88, TYPE L ASSEMBLED WITH WROT COPPER SOLDER JOINTS FITTINGS AND 95-5 TIN/ANTIMONY SOLDER PER ASTM B32 GRADE 50A. INSULATE ALL DRAIN PIPING WITH i" THICK GLASS FIBER INSULATION WITH ALL SERVICE JACKET, ASTM C547. USE HEAT BONDING OR PRESSURE TAPE TO CLOSE INSULATION. STAPLES ARE PROHIBITED. CONDENSATE PUMP: LITTLE GIANT VCMA-15UL, 1/50 HP, 115V/60/1, 50 GPH © 5'. 6 > REDUCED PRESSURE ZONE ASSEMBLY: WATTS MODEL 009. BALL VALVE: NIBCO MODEL S-585-70. EFHE \CE NAWI\GS 109-101-4420 M2 CO\JSTUCTIO\ \OTES PROVIDE (N) 1 INSULATED TYPE L COPPER CONDENSATE DRAIN PIPING. TERMINATE AT (N) CONDENSATE PUMP. SLOPE PIPE AT 1/4" PER FOOT MINIMUM. PROVIDE 3/4" DRAIN CONNECTIONS TO HUMIDIFIER AND DRAIN PAN. PROVIDE (N) CONDENSATE PUMP. POC OF (N) 1/2" PUMPED DRAIN PIPE TO (E) 1/2" PUMPED DRAIN PIPING. PROVIDE TWO (N) CHECK VALVES; NIBCO S-413. PROVIDE (N) 3/4" PW TO (N) D.I. BOTTLE CABINET. CONNECT TO (E) CW. PROVIDE (N) REDUCED PRESSURE DEVICE AND ROUTE DRAIN DOWN TO FUNNEL DRAIN ON FIRST FLOOR. RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER (Al (D) (E) (H)(JIJa) SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 l'/- V T T T T 1M110 1M111 1M112 1M113 1M114 1M115 1M116 1M117 1M118 1M119 1M120 1M121 1M122 1M123 /1M120 1M125 1M126 1M127 1M128 1M129 1M130 1M131 1M132 1M133 M134 1M135 1M136 1M137 1M138 1M139 1M140 1M140 1M142 1M143 4144 1M145 1M146 KEY PLAN SCALE: NONE 11 16' �- 1111111 - SCALE: SCALE: 1/8"=1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE K CFAC CONSOLIDATION 57822000 HARR RWS 01/25/08 Q INSTALL POWER AND AIR DROPS K-11 W1624326 SAZAN/SS 04.25.13 L M N P CABINET & CABLE SHOP RELOC. ADD DRAIN PUMP TO J-13 SINK EPME DESIGN CEILING AIR DROP & POWER CMM RELOCATION 18040606 9048615 10885518 11622265 HARR HARR M.WONG M.WONG RWS RWS RWS 10/28/08 06/08/09 R 9-101 FREIGHT ELEVATORS S ADC HVAC UPGRADE W1967797 21406-W01969369 SAZAN/GB SAZAN/FPW 09.23.13 10.25.13 07.13.10 03.24.11 J ADD AIR DROP IN ROOM 11N13 6083381 HARR RWS 12/21/07 rAFEZAW ® �r- Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE PLUMBING PLAN CURRENT REVISION 21406—W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J—N/11-15 DEV. CENTER, WA SHEET 1M124 JOB NO. COMP NO. DWG NO. 09-101-1M124 MOST REMOTE AREA FOR RACK STORAGE 3000 SQ.FT 0.18 DENSITY, 45 SPK 1027.3 GPM 138.3# SEE DWG. 109-101-4578—M1 MATCH LINE SEE DWG. 109-101-4578—M1 SEE DRAWING 109-101-4578—M1 EX. TO VALVE SV -904 AT COL. N.5/1 2" FH a. r 2Y" /—W/ 1Y"PLUG v,,, 2" 2 P.O.C. 2" Y 1Y" 4 RAIN VALVE CU x x 0 FREEZER WALK—IN MSS S0031073002 1" DRAIN VALVE SEE DWG. 109-101-4585—M1 R r. 1Y4 1Y" 4 —413 9--r fl 1Y" " 1Y" 4 1Y" 4 71 2. +1 AUX. DRAINS ----EP (5"UP I 0 0 FOR CONT SEE DWG. 109-101-4584—M2 0 0 0 0 w 0 0 0 J 0 0 0 0 0 ° 0 0 0 x x 0 x 0 x 0 x 0 0 0 0 0 9 LEGE\J —•— STANDARD SPRINKLER, PENDANT (165° UNLESS OTHERWISE NOTED) —0 (NEW) STANDARD SPRINKLER, PENDANT (165° UNLESS OTHERWISE NOTED) 6 SPRINKLER PIPING, SIZE AND SLOPE TO LOW POINT DRAIN SPRINKLER RISER (ALARM VALVE OR UPPER FLOORS WATER MOTOR GONG i X PIPE HANGER 2 -WAY EARTHQUAKE BRACING 4 -WAY EARTHQUAKE BRACING Y2" VIKING MODEL M STD ORFICE DRY ADJUSTABLE PENDENT, 8" LONG 155°F WITH DRY SPRINKLER GUARD (TYP. OF 2) SPRINKLER LEGEND SYMBOL DESCRIPTION QUANTITY 1/2" PLAIN UPRIGHT FUSIBLE LINK 165'F TEMPERATURE RATING 18 0 1/2" PLAIN UPRIGHT BULB TYPE 286'F TEMPERATURE RATING 36 1M263 TOTAL 54 GE\EAL \OTES SEE GRINNELL DWG #29 DATED 2-22-57 FOR LOCATIONS OF HOSE CABINETS NOTIFY BOEING FIRE DEPARTMENT 24 HOURS IN ADVANCE OF DOING WORK (206)655-7700. THE SHUT-OFF VALVE SV#904 IS LOCATED AT COL. N.5/1 EFERE\CE DRAWI \GS 109-101-4583-M1 ORIGINAL MYLAR 109-101-4584-M1 ORIGINAL MYLAR 109-101-4585-M1 ORIGINAL MYLAR 109-101-4991-M15 ORIGINAL MYLAR 109-101-4991-M 18 ORIGINAL MYLAR REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 RELOCATE (E) LOW POINT DRAIN TO OUTSIDE THE CLEAN ROOM. City of Tukwila BUILDING DIVISION 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 M13-ia7 RECEIVED CITY OF TUKWILA CCT 292013 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 Z r 1M260 1M261 1M262 1M263 1M264 1M265 1M266 1M267 /1M268i 1M269 1M270 1M271 1M272 1M273 1M274 1M275 1M276 1M277 1M278 1M279 1M280 1M281 1M282 1M283 f M284 1M285 1M286 1M287 1M288 1M289 1M290 1M290 1M292 1M293 1 294 1M295 1M296 8' KEY PLAN SCALE: NONE 4' SCALE: 1/8"=1'- 16' SYM A B' C REVISION D EXTRS: 21-03 RELOC. IMO TOOL STORAGE FIR 25275 DISC#10861 SPK INSTALLATION ADC RECORD SET ADC HVAC UPGRADE J#180371-00 8513444 BY CH/KB M.WONG WH APPROVED DATE SYM REVISION BY APPROVED DATE 8.9.99 RWS 12.02.09 04.01.13 21406—W01969369 SAZAN/FPW 10.25.13 irASFEZAW° Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE FIRE PROTECTION FIRST FLOOR PLAN CURRENT REVISION 21406-W01969369 SYMBOL D DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 9-101.1 COL. J -N/6-11 DEV. CENTER, WA SHEET 1M268 JOB NO. COMP NO. DWG NO. 09-101-1M268 \ / TO SV -9112 O FREEZER WALK—IN BEHC 31-076979 STORAGE 2" BRANCH ,.INE FROM 17' AFF TIED INTO 5 CROSSMAJN IN TRANSPORTATION AISLE SE DWG. #109-101-4950- 1 i 1 1/2" 1" LOW POINT DRAIN WITH A VALVE INSTALLED IN THE VERTICAL 5' AFF WITH PLUG. 2 1/2" 2 1/2" X 2 1/2" X 1 1/2" GROOVED TEE W/ 1 1/2" X 1 1/4" BELL REDUCER PARTIAL PLAN VIEW R EVIEWED FOR E COMPLIANCE APPROVED APR 0 3 2014 ity of Tukwila LDING DIVISION 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 LEGEND —II- (EXIST) STANDARD SPRINKLER, PENDANT (165' UNLESS OTHERWISE NOTED) —o-- (NEW) STANDARD SPRINKLER, PENDANT (165' UNLESS OTHERWISE NOTED) - i— (EXIST) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) —0— (NEW) STANDARD SPRINKLER, UPRIGHT (165' UNLESS OTHERWISE NOTED) 6 SPRINKLER PIPING, SIZE AND SLOPE TO LOW POINT DRAIN ® SPRINKLER RISER (ALARM VALVE OR UPPER) FLOORS WATER MOTOR GONG WATER MOTOR GONG , PIPE HANGER - 2—WAY EARTHQUAKE BRACING 4—WAY EARTHQUAKE BRACING GE \ ERAL \OTES DESIGN IN ACCORDANCE WITH NFPA 13. DESIGN SHALL ALSO COMPLY WITH FM GLOBAL REQUIREMENTS. THE BOEING FIRE DEPARTMENT SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, FLUSHING OF PIPES AND HYDROSTATIC TESTS ON THE FIRE PROTECTION SYSTEM. PERFORM PRESSURE TESTING OF PIPES AND CHECK FOR LEAKS. PROVIDE HANGERS IN ACCORDANCE WITH NFPA 13. 5. THE FIRE PROTECTION CONTRACTOR SHALL BE LICENSED IN THE STATE OF WASHINGTON. PROVIDE FOUR SETS OF STAMPED INSTALLATION DRAWINGS BY A FIRE PROTECTION SPECIALIST WITH A WASHINGTON STATE LEVEL 3 CERTIFICATE SHALL BE PROVIDED TO BOEING FOR PRE - CONSTRUCTION REVIEW AND APPROVAL BY BOEING FIRE PROTECTION ENGINEERING. DRAWINGS ARE TO BE "AS -BUILT" AFTER CONSTRUCTION IS COMPLETE, AND PROVIDED TO BOEING. INCLUDE HYDRAULIC CALCULATIONS AND EQUIPMENT DATA. ALL EQUIPMENT SHALL BE UL LISTED AND FM GLOBAL APPROVED FOR ITS INTENDED USE. .EFHE\ CE DRAWI\GS SEE GRINNELL DWG #29 DATED 2-22-57 FOR LOCATIONS OF HOSE CABINETS UCTIO\ \OTES PROVIDE SPRINKLER COVERAGE BELOW (N) EQUIPMENT PLATFORM. M13 -1R7 RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 om T '/ -V T 1M260 1M261 1M262 1M263 1M264 1M265 1M266 1M267 1M268 1M269 1M270 1M271 __, 1M272 1M273 r , i1M274i 1M275 1M276 1M277 1M278 1M279 1M280 1M281 1M282 1M283 M284 1M285 1M286 1M287 1M288 1M289 1M290 1M290 1M292 1M293 1294 1M295 1M296 KEY PLAN SCALE: NONE 4' IMO 0 11 16' SCALE: 1 /8"=1'- SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A RELOCATE BLUESTREAK J#137050-16 KGP B REMOVE FREEZER W1202204 M.WONG RWS 10.09.12 C ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 rzr,Ava ® o'— Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE FIRE PROTECTION FIRST FLOOR PLAN CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENCINEER CHECKED DOUG. HAN APPROVED 11.15.2008 APPROVED RALPH. SQUIRES 11.21.2008 TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 9-101.1 COL. 11 -15/J -N DEV. CENTER, WA SHEET 1M274 JOB NO. COMP NO. DWG NO. 09 -101 -1 M274 A R -A\DLI\n , /GILLE \ITS EQUIPMENT AREA SERVED FAN COOLING COILS HEATING COILS AIR FILTERS REMARKS CFM TOTAL S.P. IN H2O FAN SIZE FAN RPM VOLT / PH BHP HP WHITE ENTERING AIR °F LEAVING AIR °F WATER °F COIL MAX. FRICTION MCD ENT. AIR LV. AIR HOT WATER MIN. FACE MAX. FRICTION MAX. FACE VEL. RATED CAPACITY TYPE AIR FRICTION MAKE & MODEL OR APPR. EQUAL CFM DRY BULB WET BULB DRY BULB WET BULB GPM ENT. TEMP. LV. TEMP. MIN. FACE MAX. FINS. MIN. ROWS AIR WATER CFM ° FD. B. ° FD. B. EWT LWT GPM MAX. FINS. ROWS AREA SQ. FT. AIR WATER AH2N13 ADC (SUPPLY) 5,000 5.25 182 CLASS 2 2341 460/3 6.0 7.5 10 IN H2O FT H2O 6 IN H2O FT H2O 497 FPM 5,000 MERV 8 MERV 14 0.16 0.41 PRE -PLEAT 40 LPD RIGID AIR 1,2,3,4,5,6,7,8,9 5,000 80 65 54.3 53.9 23.6 42 56 10.1 FT2 FPI 6 0.81 2.7 5,000 45 91.1 180 160 10.0 FPI 2 10.1 0.15 3.75 AH2N13 ADC (RETURN/EXHAUST) 5,000 2.0 182 CLASS 1 1819 460/3 2.6 5.0 - - - - - - - - - _ - - - - - - - - - - _ _ - - - - - - - - - - 1,2,3,4,5,6 NOTES: 1. DIRECT DRIVE PLENUM FANS 2. VFD PROVIDED BY OTHERS 3. INTERNAL FAN ISOLATION, 2" SPRING DEFLECTION 4 TEFC PREMIUM EFFICIENCY MOTOR 5. DUAL DISCONNECT 6. 25KA SCCR 7. MAGNAHELIC GAGE FOR FLOW MEASUREMENT OF SUPPLY AIR AND RETURN 8. ULTRASONIC HUMIDIFIER, CONTROLS AND DI WATER TREATMENT, 150 LB/H, TREATMENT 2@2.2 CU FT MIXED MEDIA BOTTLES. HUMIDIFERS MOUNTED IN 9. ENERGY LABS MODEL C-042-056-FCH-L AIR STULTZ HUMIDIFIER DAH -30-S (4 REQUIRED), STULTZ CONTROL PANEL ULS-4-DAH-30, STULTZ WATER AHU DISCHARGE, CONTROL PANEL AND WATER TREATMENT SHIPPED SEPARATELY FOR FIELD INSTALLATION AIR DIFFUSE / EGISTE /GILLE SCHEDULE MARK NUMBER TYPE MATERIAL FINISH INLET NECK SIZE, �NCHES) FACE SIZE (INCHES) MAX. TP INCH WG. MAX. NOISE COEFFICIENT MAXIMUM SET CFM MAKE MODEL REMARK (CD) SQUARE SUPPLY DIFFUSER STEEL WHITE 12x12 24x24 0.08 25 600 MCD 89 (RG) EGGCRATE RETURN GRILLE ALUMINUM WHITE 18x18 20x20 0.07 19 1450 50FTITUS 91 87 81 79 77 SUPPLY FAN OUTLET 82 80 93 93 84 84 EQUIPS E\T SOU\D POWER LEVEL SCHEDULE EQUIP NO MAX SOUND POWER LEVEL dB RE 10-12 W REMARKS OCTAVE BAND CENTER FREQUENCY HZ 63 125 250 500 1000 2000 4000 8000 AHU2N13 80 79 90 84 81 78 77 75 RETURN FAN OUTLET 77 76 89 79 73 72 72 71 RETURN FAN INLET AHU2N13 87 86 93 91 87 81 79 77 SUPPLY FAN OUTLET 82 80 93 93 84 84 82 79 SUPPLY FAN INLET REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION LEGE \D GE\EAL \OTES EFHE\CE NAWI GS CO\STUCTION \OTES PROVIDE NEW AH2N13 AS SCHEDULED. PROVIDE NEW GRILLES AND DIFFUSERS AS SCHEDULED. Mi3•Ici7 RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ADC HVAC UPGRADE 21406—W01969369 SAZAN/FPW 10.25.13 - �BOE/NG° �r Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE EQUIPMENT SCHEDULES CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 DEV. CENTER, WA SHEET M1M JOB NO. COMP NO. DWG NO. 09-101-M1M SEQUENCES OF OPERATIC\ GENERAL FUNCTIONAL REQUIREMENTS A.CONTROL OF EQUIPMENT AS DESCRIBED IN THE SEQUENCE OF OPERATIONS SHALL INCLUDE: 1. TIME AND HOLIDAY SCHEDULES 2. OPTIMUM START CONTROL AS PER WASHINGTON ENERGY CODE. 3. ALARM LIMITS AND HISTORIES 4. SUMMARY OF DATA FOR EACH ZONE 5. TREND LOGS AND HISTORICAL DATA 6. ALL SETPOINTS B.THE FOLLOWING POINT DESCRIPTIONS AND SEQUENCES OF OPERATION SHALL BE ENHANCED AS NECESSARY AND INCLUDED AS PART OF THE CONTROL DRAWINGS TO EXPAND AND CLARIFY INFORMATION SHOWN ON THE DRAWINGS. 1. POINTS INFORMATION SHALL BE DISPLAYED AND ORGANIZED BY SYSTEM IN DYNAMIC GRAPHIC FORM AT THE OPERATOR STATIONS. 2. IT SHALL BE POSSIBLE TO "DISCONNECT" ANY OUTPUT OR SETPOINT FROM THE AUTOMATIC CONTROL LOGIC AND ENTER A MANUAL OR STATE FROM ANY OPERATOR STATION. 3. IT SHALL BE POSSIBLE TO REPLACE ANY INPUT WITH A MANUAL VALUE FROM ANY OPERATOR STATION. 4. ALL CONTROL LOOP PARAMETERS FOR EACH LOOP SHALL BE DISPLAYED ON ONE DISPLAY. C. THE FOLLOWING COMMANDS, DISPLAY AND DATA SHALL BE AVAILABLE AT THE OPERATOR STATION: 1. AIR HANDLING UNIT A. FANS STATUS (FROM VFD) B. OUTSIDE AIR TEMPERATURE C. MIXED AIR TEMPERATURE D. SUPPLY AIR TEMPERATURE E. OUTSIDE AIR DAMPER % OPENING F. RETURN AIR TEMPERATURE G. COLDEST AND WARMEST ZONE, ALL ZONES SAMPLED H. DUCT STATIC PRESSURE I. ALARMS (TEMPERATURE, AIRFLOW, PRESSURE, FILTER) D. THE FOLLOWING POINTS ARE REQUIRED IF NEEDED BY CONTROL STRATEGY: 1. DIRECTLY MEASURED TOTAL OUTSIDE AIRFLOW (CFM) E. THE FOLLOWING POINTS SHALL BE DISPLAYED USING CALCULATED VALUES BASED UPON COMMAND POSITION UNLESS EXACT VALUES, AS INDICATED BY A FEEDBACK SIGNAL, ARE REQUIRED BY CONTROL STRATEGY: 1. FAN SPEED (PERCENT OF FULL SPEED) 2. DAMPER POSITIONS (PERCENT OF FULL OPEN) F. AIR TERMINALS 1. CURRENT SPACE TEMPERATURE 2. OCCUPIED HEATING/COOLING SETPOINT 3. UNOCCUPIED HEATING/COOLING SETPOINTS 4. CURRENT STATUS (HEATING/COOLING) 5. CURRENT MODE (DAY/NIGHT) 6. HIGH/LOW TEMPERATURE ALARM AIR HANDLING UNIT AH2N13 A. START -STOP AND FAN SAFETIES: 1. SAFETY FEATURES: THE FOLLOWING SHALL PREVENT FAN OPERATION UNDER ANY MANUAL, BY-PASS. THESE SAFETIES SHALL BE HARD -WIRED AND SHALL NOT RELY ON EMCS CONTROL. A. DIVISION 26 FIRE ALARM OUTPUT. B. HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1. C. FREEZESTAT (FREEZE PROTECTION). D. RETURN AIR DUCT -MOUNTED SMOKE DETECTORS WILL BE PROVIDED BY DIVISION 28. THE DETECTORS WILL COMMUNICATE WITH THE DIVISION 26 FIRE ALARM SYSTEM. AN OUTPUT MODULE WILL BE PROVIDED UNDER DIVISION 26 (IN THE GENERAL VICINITY OF THE VFD), WHICH WILL PROVIDE FIRE ALARM CONTROL OUTPUT FOR THE AIR HANDLER. EMCS CONTROL SHALL REPORT SMOKE DETECTORS STATUS. 2. ACTION - NORMAL OPERATION: A. IF THE VFD CONTROL SWITCH IS IN "AUTO" AND THE EMCS IS SET TO ALLOW OPERATION OR IF THE VFD CONTROL SWITCH IS IN "ON" POSITION; THEN RETURN AIR DAMPERS AND OUTSIDE AIR DAMPERS SHALL START OPENING; DAMPERS SHALL MODULATE ACCORDING TO SUPPLY AND OUTSIDE AIRFLOW REQUIRED IN THE BUILDING. IF SAFETIES ALLOW OPERATION; THEN START THE SUPPLY & RETURN FAN. THE FANS SHALL RAMP UP TO AND OPERATE AT THE COMMANDED SPEED (SEE BELOW). IF ANY OF THE ABOVE CONDITIONS CHANGE, THEN THE FANS SHALL STOP OPERATING. 3. ACTION - SUPPLY FAN SPEED CONTROL: A. SUPPLY FAN SHALL OPERATE AT THE SPEED COMMANDED BY THE STATIC PRESSURE SENSOR PT2 LOCATED IN THE AIR DISTRIBUTION SYSTEM AT 2/3 OF THE DISTANCE FROM THE LONGEST RUN. 4. ACTION - FAN SHUTDOWN: A. IF THE HIGH PRESSURE CUTOUT PRESSURE SWITCH PT1 ACTIVATES, THE EMCS SHALL COMMAND THE UNIT TO SHUT DOWN UNTIL RESET THROUGH THE EMCS. IF THE SMOKE DETECTORS ARE ENERGIZED THE UNIT SHALL SHUT DOWN. THE FANS SHALL DECREASE IN SPEED AND STOP. ALL DAMPERS SHALL CLOSE. DAMPERS END SWITCHES SHALL CONFIRM THAT THE DAMPERS ARE CLOSED. 5. SPECIAL ALARMS: A. DAMPERS NOT IN FULL CLOSED POSITION WHEN UNIT IS OFF. B. PROVIDE DIRECT READOUTS OF FILTER PRESSURE DROP USING DIFFERENTIAL PRESSURE SENSOR (PS). PROVIDE WARNING ALARM WHEN AT CHANGEOUT PRESSURE. C. DISCHARGE TEMPERATURE CONTROL: 1. DISCHARGE AIR TEMPERATURE SHALL MODULATE TO MAINTAIN ROOM SETPOINT TEMPERATURE. 2. HUMIDIFICATION: HUMIDIFIER SHALL OPERATE TO MAINTAIN A MINIMUM RELATIVE HUMIDITY OF 30% (ADJUSTABLE). 3. DEHUMIDIFICATION: COOLING COIL SHALL OPERATE TO MAINTAIN A MAXIMUM RELATIVE HUMIDITY OF 70% (ADJUSTABLE). HEATING COIL SHALL MODULATE TO MAINTAIN ROOM SETPOINT TEMPERATURE. SPACE RELATIVE HUMIDITY SET POINT (MAXIMUM) = 60%. SPACE TEMPERATURE SET POINT = 72°F±5°. D.I. WATER CHILLED WATER ZONE 1 ZONE 2 ZONE 3 COLUMN COLUMN COLUMN M-13 M-12 M-110 HUMIDIFIER FAN AR HA SCALE: NONE HEATING COIL \DLI\G U\IT COOLING COIL CO\TQC L DIAGA FAN Vl (AH2\13) REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION TO FIRE ALARM & HARDWIRED TO FANS ❑ El D i Rn VFD ❑E a LEGE\D TEMPERATURE TRANSMITTER ROOM TEMPERATURE SENSOR PRESSURE TRANSMITTER AIRFLOW TRANSMITTER FREEZE STAT OVERFLOW DETECTOR HUMIDITY TRANSMITTER DIFFERENTIAL PRESSURE SENSOR MOTOR SMOKE DETECTOR (BY ELECTRICAL) VARIABLE FREQUENCY DRIVE WITH FAN START/STOP, FAN RPM OUTPUT AND FEED BACK FAN ELECTRIC MOTORIZED CONTROL VALVE ELECTRIC MOTORIZED DAMPER WITH END SWITCH AIRFLOW DIRECTION 'E\ HAL \OYES EFEH CE DRAWI \GS CO\ST UCTIO\ \ OTES V1131,37 RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER 21406-W01969369 ISSUED FOR CONSTRUCTION .10.25.13 RAZAN GROUP. 600 Stewart St., Ste 1400 Seattle, Washington 98101 fir) Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 SYM REVISION ADC HVAC UPGRADE 21406—W01969369 BY SAZAN/FPW APPROVED DATE SYM REVISION BY APPROVED DATE 10.25.13 Q� BOE/NG° Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE SEQUENCE OF OPERATIONS CURRENT REVISION 21406401969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 DEV. CENTER, WA SHEET M318 JOB NO. 160530-00 COMP NO. DWG NO. 09-101-M318 RETURN AIR DAMPER OUTSIDE AIR DAMPER RETURN FAN MERV 8 PRE FILTER MERV 14 FINAL FILTER ON COMMON RACK SUPPLY FAN SUPPLY OUTLET 56 ACCESS DOOR (TYP) 48 f' ULTRASONI HUMIDIFIER o.3 ES .3 `oo J Eo0° J ° ° LOAD J. _ o 1 0 41 ° 3 Eo rel ° C Eo •. �- T� .a. M 1 'I / 1 1 .. IIII .. .. I Y I I 1. EXHAUST DAMPER 54 1 1213 12.13—I -12.75—I \\ 1 1 CHILLED WATER COIL PROVIDE '1/2" GALVANIZED HARDWARE CLOTH SCREEN T T T DRAIN PAN HOT WATER COIL LAN VIEW MAGNEHELIC FILTER GAUGES (TYP 2) DRAIN PAN OBSERVATION WINDOW 50 INTERNAL FAN ISOLATION (TYP) 12.75 3575 0j 3 47 I Ir 35.7 9 24 47 46.5 19 47 1 99 46.5 19 or 24 27 47 24 47 3o 36 PL 60 PF 16 PFF 27 36 CC AH2N13 SCALE: 1/2"= 1 '- 0" 304 SIDE VIEW 29 PL 9 HC 29 PL 53 PF 30 36 PL 1M24 ,E'�IEwED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City . . i of 'Tukwila BUILDING DIVISION LEGE\D GE \HAL \OTES EFE E\CE DAWI\CS CO ST UCTI \OTES RECEIVED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER 21406—W01969369 ISSUED FOR CONSTRUCTION 10.25.13 SAZA.N GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN #364-1306 SYM REVISION ADC HVAC UPGRADE 21406—W01969369 BY SAZAN/FPW APPROVED DATE 10.25.13 SYM REVISION BY APPROVED DATE Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE AHU DETAILS CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 DEV. CENTER, WA SHEET M621 JOB NO. COMP NO. DWG NO. 09-101-M621 CONTROL PANEL VFD (TYP 2) 24X24 VAC CW 18X36 HWS&R i zi PLATFORM 10'-0" BRANCH DUCT �l I SQUARE CEILING DIFFUSER 1/ \ SUPPLY DUCT VOLUME DAMPER (TYP) CEILING CEILI\G DIFFUSES DETAIL (� SCALE: NTS 1M24 M622 MAIN C/A OR VAC. HEADER (BMI PIPE) DICKSON OR MACRO -TECHNOLOGIES HOSE HOSE, 1/2" MPT X 1/2" HOSE BARB (TYP 2) BAND -IT #CP -311 HOSE CLAMP (TYP 4) BOSTON PERFORMER OR MACRO -TECHNOLOGIES 1/2" HOSE RATED TO 250 PSIG OR 29" HG KELLEMS GRIPS USE IRON PIPE & MALLEABLE IRON FITTINGS BELOW S.O.V. KELLEMS SAFETY SPRING 1/2"BALL VALVE HOSE DROP SCALE: NTS MOUNTING HEIGHT: 7'-0" ABOVE FLOOR (4 1M118 M622 SECTIO \ Y„_1, -O„ 4 1/2' FPT LOCKING 150# BALL VALVE WATTS OR EQUALL/#B-6000LH 3/8"x 3/8"x 1/2" IPS REDUCING TEE PITCH DOWN TOWARD DRAIN CLEAN OUT 1M24 M622 DRAIN LINE SHALL BE AT LEAST THE SAME SIZE AS THE NIPPLE ON THE DRAIN PAN (3/4") MIN. OPEN VENT TO CONDENSATE PUMP DRAIN PAN UNIT TYPE A B BLOW THRU 1" MIN. FAN OUTLET PRESSURE ("WC) + 1" MINIMUM DRAW THRU 1” MIN. FAN INLET PRESSURE ("WC +1") / 2 AIS HA\DLI\G U\IT D SCALE: NTS CEJN 10-310-1454 3/8" MPT x 1/4" SOCKET QUICK DIS- CONNECT (2 PLACES) SYMBOL: SCALE: NONE T SAP ETAIL IL(2Th KINDORF C-105 PIPE CLAMP 1/2" IPS x 4" OR EQUAL LONG NIPPLE 3/8" IPS STREET ELBOW (2 PLACES) STD DUPLEX AR DROP — WALL 1/2" 3�A\CH WITH 1/4" SOC SCALE: NONE v 1M124 M622 1 8 > CONTROL VALVE Lim CIRCUIT SETTER THERMOMETER (TYP) CHWR MV (TYP) 6 > BALL VALVE (TYP) CHWS t--�-I PUMPED CONDENSATE UP TO HARDLID 4'-6" FROM FLOOR NOTES 1. MSS ASSY: STDP09 2. ALL FIGS MALL IRON OU <EIS TED 1M118 M622 CONDENSATE PUMP HOT WATE COCLI\ SCALE: NTS WALL OR STRUCTURE (REF) WALL BOARD ANCHOR SCREW AND WASHER MOLLY BOLT OR EXPANDING TYPE ANCHOR (2 PLACES) B -LINE B-22 CHANNEL OR EQUAL HEATI G COIL CO 1/ x CONTROL VALVE CIRCUIT SETTER 1 THERMOMETER (TYP) • P -TRAP • STRAINER I ► 10 HWR PRESSURE GAUGE (TYP) III cI 10 HWS 1" CONDENSATE DRAIN SLOPE 1/4" PER FT G &CHILLED WATE \ECTIO\ DETAIL 2"CW, SEE FLOOR PLAN MIN. 24" AFF HARD LIDMAX. 60" AFF REDUCED PRESURE BACKFLOW PREVENTER ASSEMBLY I � 1 1M74 M622 (PF -H AIR GAP FITTING --� EDUCED PHSSU 3AC<FLOW PEEVE SCALE: NONE \TE 3/4"CW DETAIL (6 1M124 M622 SYM REVISION BY APPROVED ADC HVAC UPGRADE 21406-W01969369 SAZAN/FPW DATE 10.25.13 SYM REVISION BY APPROVED DATE pirAv BOEG° Expires: 06/29/14 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE LEGE\D GE EAL \OTES AUTOMATIC AIR VENT (AAV): BRASS VENT RATED TO 150 PSIG, 4" NPT, TACO MODEL 409. PRESSURE GAUGE: 4-1/2", DIAL - WHITE ALUMINUM WITH BLACK MARKINGS, WINDOW - GLASS, POINTER BLACK ALUMINUM, SOCKET - BRASS, BOURDON TUBE PHOSPHOR BRONZE C TUBE, ACCURACY - 1.0% ASME B40.1 GRADE 1A, RANGE: 0-100 PSI, CONNECTION i"NPT, WEISS MODEL 4PG-1. SNUBBER: MODEL PSN -S-50. NEEDLE VALVE: MODEL 5ONVBR. THERMOMETER: 6" CASE, GLASS WINDOW, BRASS CONSTRUCTION, ANGLE FORM, THERMOWELL, WEISS MODEL 5AS2-240 (HOT WATER), MODEL 5AS2-120 (CHILLED WATER). WYE STRAINER: CAST BRONZE, SCREWED, CLASS 250, 20 MESH, 304 SS SCREEN, MUELLER MODEL 352M. BALANCE VALVE: VICTAULIC TA SERIES 787. 6 > BALL VALVES: TWO PIECE, FULL PORT, BRONZE TRIM, 600 PSI CWP, MSS -SP -110, NIBCO T-585-70. HOT WATER CONTROL VALVE: TWO WAY, CHROME PLATED BALL, BRASS STEM, CHARACTERIZED BALL TYPE, BELIMO MODEL B207(B), i", CV=0.3, NON -SPRING RETURN. 1 8 > CHILLED WATER CONTROL VALVE: TWO WAY, CHROME PLATED BALL, BRASS STEM, CHARACTERIZED BALL TYPE, BELIMO MODEL B214(B), i", CV=7.4, NON -SPRING RETURN. 9 > FLEXIBLE CONNECTOR: BRAIDED FLEXIBLE METAL FLANGED CONNECTOR, 321 SS HOSE, 304 SS OUTER BRAID, 150# CS FLAT FACED FLANGES, KINFLEX MODEL BFMC-FFF. EFHE \CE DV\WI\GS CO\STUCTIO orfs M13i97 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 3 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 292013 PERMIT CENTER 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 CHECKED ENCINEER SUBTITLE SECTIONS & DETAILS CURRENT REVISION 21406-W01969369 SYMBOL DATE 10.25.13 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 DEV. CENTER, WA SHEET M622 JOB NO. COMP NO. DWG NO. 09-101-M622 3 30 3/4"C, 6#10 TO LTG BELOW MEZZ. SEE 1E18 & 1E24 #124 5 KVA 277V-240/120 SEE 1E12 30 KVA 3P 480/120-208V Al2C O30 2 30 #126 19 LIU #123 1 #10 #1� 3#10 DEA FOR CONTINUATION SEE DWG 09-101-1 E118 7 1/2 HP TO 480V BUS, PI -20 60A FUSED TO MOTORS EF12-EF13 ON ROOF AT M/9. SEE DWG. 9-101-1E118 r #16 1 1/4"c, 4#2 3/4"C, 3/4"C, 3#8--1 UP TO 2ND FLR 30 KVA 480-120/208 3#10 DEAD #156 #160 1-431in 30 30 #166 leave empty conduit BD 32F3-15 #18 n#184 Q EF - F-- off, toggle om ol. N-P/p-10 P #8 ABV CAPPED CLG 6#1 0 0 /// /// C� GE\EAL \OTES 1.) ALL CONDUIT TO BE 1/2 EMT UNLESS OTHERWISE NOTED. 2.) ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3.) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4.) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5.) AL • SED CONDUIT AND WIRE TO BE REMOVED BACK TO __,/r- INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAY. 6.) FE ' ` TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. tABOL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETA ' WTi-I CIRCUIT IDENTIFICATION. 8.) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. BD 33F2-27 STATE DISC SANDER #163 #1811 CLAUSING TWO SPEED DRILL PRESS #10 BALDOR PED. GRINDE 3/4"C, 12#12 TO LIGHTING (2) FUME HOODS SEE SHT. 1E74 SEE E197 FOR CONTROLS XSP13/25a CO2 ALARM CIRCUIT IBMARIA DRILL PRESS 3/4"c, 3#8 CABLE FESTOON Pr) N LU MAX SPINDLE SANDER rn /1/ O// DUST COLLECTOR INTERLOCK ENCLOSURE SEE DRAWINGS 1E504 AND E100 DO -ALL BANDSAW GROB BANDSA 1 1/2"- 3#2 3/4" 3#19 1E503 To Dust Collector Control Circuit M-' 1/2"R, 3#1 DUST COLLECTOR INTERLOCK ENCLOSURE, SEE DWG. 1E503 CINCINNATI MACHINE 31-049101 Plug—In Unit #10 30 KVA WITH 100A C.B. w w 0 i1 1/2"- 3#2 TO 2ND NEL 2N12 DUST COLLECTOR UP TO 2ND FLR. 75KVA, XFMR PNL 2M I-- T 0 U 0 DUST--COLLECTO BD -33F3 -287-400N 71#92 _BD 13F5-16 LSI#93 # #8 8/4 'SO' CRANE DISG�� CRANE CONNECTON IN FREEZER 1 "3#4-b, 2"-4#2/ PNL 1J1 CINCINNATI MILICRON 2.6 FLA SUNNEN HONING MAC 480/120 3208vW 1 1/4"-4#2 3/4"-3#8 45 KVA, 30 4W 480/120-208v Ws 1E74 MILL 200 OL #8 WALK-IN FREEZER BEHC 31-073002 Dead -End 30A -480V 45 48 2 3208v 0/10 �1"C,17#12 L MONARC LATHE 3/4"C, 4#12 TO LIGHTING TRANSPI RTATION AISLE 1 PEDEST'AIN WALKWAY BD 13F1-17 #10 #150 #154 •3r1 --%r 0 0 #50 #52 15 1 1/4"c, 4#2 TO PNL 1N13 PNL. IN13-1 2"C, 4#3/0 TO P , 1N13.2 31A 277V 10 SPOT COOLER 480-208/120,30,4W FILTER UNIT 1 "C #6 ABOVE CEILING u7 w 0 rn 0E3-- 0 o CONTINUATION SEE CC RaoireolmE TO UNKNOWN LOAD #107 #109 #115 MAZAK VERTICAL MILL 9MPS62 71A 1 /// 1 1/2-3#1/0 LJ LJ #23 #24 3/4"C, 3#10 1/2" 310 30/25 5KV71PIH - WATER HEATER 48024 V #101 1/2" 3#14 DUST COLLECTOR INTERLOCK 1/2" 6#14 a,1.Z#.12_ 30/NF 3/4" 3#10, 6#14 TO EF -3 STARTER AT RESIN RM SEE 1E130 #10 1/2"C, 3#10 TO 30A RECEPT. .., SEE 1E130 CONNECTION TO CINN-MILLICRON BEHC 30-0176676 crUP TO LTG PNL 2LK-15 PARTIAL PLA\ VIEW SCALE: 1 /8"=1'-0" 30KVA, 3PH 480-120/208V UP, SEE ¶130 (SERVICE TO PNL 1M15 AND 120/208V BUSWAYS) 1"C, 17#12 �TO AHU #31 SEE 1E130 FOR CONTINUATION SEE DWG 09-10 3/4"C, 3#10 DEAD END IN J -BOX COL. N-15 SEE 1E130 AND 1E131 1E130 CONSTUCT10 LEGE D @ 480 VOLT DROP -3 -WIRE, 4 -POLE CROUSE HINDS TYPE APR, XX APMERES. h9 480 VOLT RECEPT., 3 -WIRE, 4 -POLE, CROUSE HINDS, TYPE ARE, XX AMPERES. J -BOX 480/277V DISTRIBUTION PANEL A TRANSFORMER, CAPACITY, PHASE & VOLTAGE AS SHOWN GROUND O 480V 3 PHASE MOTOR ® MOTOR STARTER, MAGNETIC MOTOR STARTER, MAGNETIC W/ DISCONNECT SWITCH MOTOR STARTER, MANUAL DISCONNECT SWITCH, NON-FUSED, XX AMPERES MACHINE/EQUIPMENT NUMBER X, Y HORSEPOWER 480V 3 PHASE FAN MOTOR,WITH HEATING COIL MOMENTORY PUSHBUTTON SWITCH W/ PILOT LIGHT EQUIPMENT SCHEDULE ITEM DESCRIPTION PROPERTY NO. HP KW REMARKS 1 DUST COLLECTOR - 5 1E115 SERVE EQUIP. # 8,15,16 2 DUST COLLECTOR - 5 1E120 SERVE EQUIP. # 6,12,13,14 3 CM LODESTAR HOIST - - 1E125 2.2 FLA 4 GROB BANDSAW 31-070502 3 1E130 5A 5 SIP JIG BORE 10-538623 1E134 8.5A 6 GROB BANDSAW 31-070489 3 ij 1E139 1E140 7 CINCINNATI MIUCRON 31-070510 - 23 1E144 8 TREE MILLING MACHINE 39-013452 11 KVA ® 240V VIA MACH. XFMR 9 MAZAK LATHE/MILL 39-010796 60 73A 10 K & T ROTARY HEAD MILL BC 560639 460V, 12 FLA 11 BRIDGEPORT TRACER MILL 39-013556 - 4A 12 BRIDGEPORT TRACER MILL 39-013600 - 7.8A 13 BALDOR PED. GRINDER 31-070392 3/4 14 STATE DISC SANDER 31-075802 2 15 MAX 24" DISK SANDER 31-2006174 2 3.2A 16 ROCKWELL BELT SANDER 31-070381 1.5 2.7A 17 WATER HEATER - - 4500W 18 DRILL PRESS 10-544673 3 19 IBMARIA DRILL PRESS K039921 100 20 DO -ALL BANDSAW #31-076256 4.75 21 MAX SPINDLE SANDER 30-026730 1/3 22 MAX DISC SANDER 31-072111 5 23 - - 24 HAAS MILL 38KVA 30 208V 3 PH VIA 45KVA XFMR. 25 MAZAK VERTICAL MILL 39-013562 59 71 AMPS 26 MONARC LATHE 31-049185 15 AMP 27 SUNNEN HONING MACHINE 31-077230 2.6 FLA 28 CINCINNATI MACHINE 31-049101 29 - - - - 30 CLAUSING TWO SPEED DRILL PRESS 30-261135 2.1 FLA 15A FUSES IN COMBO -STARTER \ \OTES CC\T' PROVIDE SAFETY DISCONNECT SWITCH: GE THN3361 OR APPROVED EQUAL. CONNECT DUCT SMOKE DETECTOR TO AHU CONTROL PANEL TO SHUT DOWN AHU, IF SMOKE IS DETECTED. COORDINATE WITH MECHANICAL SUPPLIER FOR EXACT POINT OF CONNECTION. 21406-W01969369 ECN #1 AND DPD 03.18.14 13's i617 21406-W01969369 ISSUED FOR CONSTRUCTION 10.25.13 REFE�E\ CE DRAWI\SS 9-101-2E124 0\S UC 10 NST S DISCONNECT AND REMOVE POWER CONNECTION TO AHU-29, FAN, HEATER AND CIRCULATION PUMP. REMOVE DISCONNECT SWITCHES, CONDUIT AND CONDUCTORS BACK TO SOURCE. CONNECT DAH -1 THE BUS PLUG AS SHOWN. REPLACE EXISTING (1)3P15A CIRCUIT BREAKER WITH (1)3P30A CIRCUIT BREAKER IN EXISTING BUS PLUG. PROVIDE CONDUIT AND CONDUCTORS AS SHOWN. COORDINATE EXACT POINT OF CONNECTION WITH AHU SUPPLIER PRIOR TO ROUGH -IN. RECEIVED CITY OF TUKWILA MAR 2 8 2014 PERMIT CENTER SAZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.17 5 .:: RRENT REV I • N SYMBOL 40. '.9 I S V T T T I _, 1E110 1E111 1E112 1E113 1E114 1E115 1E116 1E117 1E118 1E119 1E120 1E121 1E122 1E123 W /��E124 1E125 1E126 1E127 1E128 1E129 1E130 1E131 1E132 1E133 1E134 1E135 1E136 1E137 1E138 ij 1E139 1E140 1E141 1E142 1E143 1E144 1E145 1E146 KEY PSN SCALE: NONE SYM REVISION V ADC HVAC UPGRADE - ECN #1 AND DPD M N 0 REMOVE MAT'L HANDLING EQUIP. SURPLUS/INSTALL DRILL PRESS HMS VERTICAL MILL SURPLUS CLAUSING MILL 21406-W01969 1792432 2386085 56800901 568009-02 BY SAZAN/SL VAVREK VAVREK L. MAY L. MAY APPROVED DATE SYM REVISION VAVREK VAVREK VAVREK VAVREK 03.18.14 02.03.06 04.19.06 Q R S 06.15.07 07.26.07 T U CPAC M&T CONSOLIDATION CABINET SHOP BUILD OUT INSTALL ROLL -UP DOOR L-13 REDLINES CD01 OS NC ADC HVAC UPGRADE 578220-00 180406-06 11305348 21406-W01969369 BY SANTOS MOBERG ESBROOK WH SAZAN/SL APPROVED VAVREK VAVREK VAVREK LEG DATE 2/5/08 11.26.08 08.27.12 01.01.12 10.25.13 BOE/HG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R. RIVERA CHECKED DATE 01/14/97 SUBTITLE 480Y1277V POWER PLAN APPROVED BY DEPT. DATE ENGINEER CHECKED JOHN J. VAVREK APPROVED 01/15/97 APPROVED NAREN METHA 01/15/97 TITLE ELECTRICAL MASTER ADC HVAC UPGRADE BUILDING 09-101 COL. J -N/11-15 DEV. CENTER, WA SHEET V DATE 1E124 JOB NO. 180406-06 COMP NO. DWG NO. 09-101-1 E124