Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-198 - OTIS ELEVATOR - REPLACE ROOF TOP UNITS
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M13-198 Otis Elevator th 3315 S 116 St #149 DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers 5 U.S.C. sec. individuals’ privacy pursuant to 5 U.S.C. sec. DR1 Generally – 5 U.S.C. sec. 552(a); RCW 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington 552(a); RCW 42.56.070(1) State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW 59 DR2 Financial Information – account numbers, which are exempt from 42.56.230(5) disclosure pursuant to RCW 42.56.230(5) RCW 42.56.230(4 5) , except when disclosure is expressly required by or governed by other law. OTIS ELEVATOR 3315 S 116 ST M13-198 Parcel No: Address: Project Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0923049068 33155116 ST 149 OTIS ELEVATOR MECHANICAL PERMIT Permit Number: M13-198 Issue Date: 12/12/2013 Permit Expires On: 6/10/2014 Owner: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 SCOTTSDALE AZ, , , 85261 Contact Person: Name: CHRIS WALKER Address: 899 W MAIN ST, AUBURN WA, , 98001 Contractor: Name: Address: License No: Lender: Name: Address: IECS INC. P.O. BOX 19252 , SEATTLE, WA, 98109 IECS***044QL Phone: (253) 939-9495 Phone: (206) 939-9495 Expiration Date: 11/20/2014 DESCRIPTION OF WORK: SUBTYPE: NRES STATUS: PENDING DESCRIPTION: REPLACE (4) EXISTING ROOFTOP HVAC UNITS Valuation of Work: $26,500.00 Type of Work: Fuel type: Fees Collected: $525.38 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: /2-(2-(3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 3: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: ***MECHANICAL PERMIT CONDITIONS*** 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukvvilaWA.goy Mechanical Pent No. Project No. Date Application Accepted: Date Application Expires: MI's' I° 4 10 799 1, 6417A (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans mist be complete in order to be accepted for plan review. Applications will not be accepted through the rmil or by fax. **please pie • SITE LOCATION 31 r J e, r King Co Assessor's Tax No.: Ot2bo'l - l Q i Site Address:, _ 1 Suite Number: j l -F9 Floor: Tenant Name: ()TLL✓ 1 5 b Lova , New Tenant: ❑ Yes 0 ..No PROPERTY OWNER Name: (.%p7 r k \,, d2 n r.. WcC Name: nRes... City: State: r n Zip 9goo 1 /_ ,, Address:/ c `=- C .7g 0 -irootl Op, s . 616 O C lfti v,(. j Xc), Stat a Z Qk l m, do CONTACT PERSON - person receiving allproject communkation Name: (.%p7 r k \,, d2 n r.. WcC Address: b 61 01 ()A&I , City: State: r n Zip 9goo 1 PhoneA53-9. I Ws -E :a i.-q,39-ga60 Email -Chu cc,0,5ea/fl-ernlecAante,f, Pan MECHANICAL CONTRACTOR INFORMATION Company Name: Z ..o . Mall0 hi:(n 'c_X, Address:sci City: a hi1 f State: 03 qZip goal Phoi>ea: t6m 3q- 9595 Fax 939- 9',.9 0 Contr Reg No.: CS * *o'-t4Z L XFExp Date: 0/09-0//1/1 Tukwila Business License No. : Valuation ofproject (contractor's bid price): $ a ( 5ev. ® Describe the scope of work in detail: ROCtel& C1) exist` Use: Residential• New ❑ Replacement 0 Commercial: New D Replacement tgl Fuel Type: Electric 1414 Gas Other: 1Eu4pleFom-AppsnchseuLx\2011AppSntffi lecems.rrcmtAppreatimRniseda-s-11.dncx Revised: Awast 2011 bb RbcYk)p uA-c u.nits Page 1 oft Indicate type ofinechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Thor fiance Suspended/walVfbor mounted heater App fiance vent Repan or addition to heat/refiigtcooling system Air handling unit <10,000 cfin Unit Type Qty Air handling tint >10,000 cfin Evaporator cooler V mtilation fan connected to single duct Ventilation system Hood and dud Incinerator - domestic Incinerator - comm/industrial Unit Type Qty Fie damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical i.p pequlpment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of eonstruedon - in allcases, a value ofconstnucion amount should be entered by the applicant. This figure wallbe reviewed and is subject to posstl} revision by the permit' center to comply with current fee schedules. Expiration of plan review- applications fin which no permit is issued within 180 days following the date of app kation shall expire by limitation. The building ofFeslnlay grant one extension oftime for additionalperiods not to exceed 90 days each. The extension sha Ube requested in writing and jus1ifrable cause demonstrated. Section 1053.2 InternationalBuildiog Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Date: (k -30 — Prart Name: 2,1A ri S f)ikQXSea-i- ay T : a�3— �— cict-91S— Mailing Address: 8 l -7 W l OW An S t i3 Stai City State Zip H: Appk stionaonns-Agplcatiuns On 1.11612011 AppreatisaMtechastialPernit ApgratvnRevised &9-11.doca Reid: Avert 2011 bb Page 2 oft Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $420.30 M13-198 Address: 3315 S 116 ST 149 Apn: 0923049068 $420.30 Permit Fee Permit Fee TOTAL FEES PAID BY RECEIPT: R354 R000.322.100.00.00 $420.30 $420.30 $420.30 Date Paid: Thursday, December 12, 2013 Paid By: IECS INC Pay Method: CHECK 55829 Printed: Thursday, December 12, 2013 1:30 PM 1 of 1 CRWYSTEMS �J��tIA wq� City of Tukwila nl \Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0923049068 Address: 3315 S 116 ST TUKW Suite No: Applicant: OTIS ELEVATOR RECEIPT • Permit Number: M13-198 Status: PENDING Applied Date: 10/30/2013 Issue Date: Receipt No.: R13-03016 Initials: User ID: JEM 1165 Payment Amount: $105.08 Payment Date: 10/30/2013 03:09 PM Balance: $420.30 Payee: IECS INC, DBA SEATTLE MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 55582 105.08 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 105.08 Total: $105.08 orntc,A• 1n_zn_Wn1A INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 • Project: O- ► 5 Type of Inspection: r 1 NJ tgL:— Addre '3-51"5 S It(o i Date Called: Special Instructions: 4 Date 1antted:k - t Cr RequesterRt �� ti � Ph2avr&3s(6f 40 Approved per applicable codes. Corrections required prior to approval. COMMENTS: nrpect• . pa aSECTION FEE RE UIRED. Por to next inspection, fee must be t'6300 Southcenter lvd.. Sui a 100. Call to schedule reinspection. Da,ey3-1 INSPECTION RECORD Retain a copy with`permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Orn<> EL4'vt4TO E Type of Inspection: SAA01,4-E S VI 1, CI bidAP L) Address: 33V0 S 1 l(, Si Date .Called: Special Instructions: Date Wanted: j2 --Z'— (.---c a.m. p.m. Requester: Phone No: ®Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: t7_' 4—L3 n RE PECTION FEE RE UIRED. Priory) next inspection, fee must be pai . :t 6300 Southcenter Blvd., Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,#100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 J r) (i\13 -IS ) Project:IJ OTT 1S r c:Fc -rik Type of Inspection: F. i , 11 L).-- ‘ P14711—/4 Address:Date )5 S + I s1--- tailed: 5 (11 o VE ,c)/21T- D Cf -ht/ kJc o" ,6 0 '1 Special Instructions: Date Wanted 12- l 11311-5 m p.m. Requester: elYfl -/r)€,a ./ Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS:. /fides T dAZ/nJiTS .I,UsWit. > 12617r6/h -,Tn/ — 410Pe e( 5 (11 o VE ,c)/21T- D Cf -ht/ kJc o" ,6 0 '1 e..3--) 1--)-v•-e 1: i Aid 1 - Alcit(et/ 74 f elYfl -/r)€,a ./ .�>;""e-% .--...� A Date: I�. 3//' NSPEC1ION FEE REQ RED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit —-3 /3— - 3"`( i) I') -- 3 L - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 8 206-575-4407 Project: Sprinklers: Fire Alarm: Ty e of I specy / -Y-77.--e___ c ttm L.._ Monitor: Address: 3 jI s Suite #: ) Up/ s // b -- Contact Person: Special Instructions: cv4- i 0 ,4( - D IC__ Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: `.- - • Permits: Occupancy Type: cv4- i 0 ,4( - D IC__ tri-. c c -C-. c, „.,1/4.42. 0K. (-<__ .1,,,_), _ o k~ s...�, j eJ --r-z, k,...,10 , 6,y ,d0,1,., . L16,,‹-‹-. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: `.- - • Permits: Occupancy Type: Inspector: 6`%1..1 S ? Date: /Z (23(/..5 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 C > NOTES: L NO CHANGE TO EXTERIOR OF BUILDING OR &NTE 2. NO CHANGE TO OCa.PANCT OR USE 3. 140 GUNGE TO PARIC139 4. NO CHANGE TO 134.1I10I46 ENVELOPE 5. LESS 11A4 65% OF FIXTURES ARE NSW AND 140 044340E N WATTAGE FI COPY Permitao. P1IS1fB - n review aio mem end I It APProval of cunof constructiond t„ violation of any adopted code or onlinance. it approved Reid and 1, ode, /2-/2-/ City Of 1b BUILDING DIVISION N.T.S. SCOPE OF WORK REMOVE 501E INTERIOR NON BEAR% STUD WALLS, 000IFa1CT 500 NEW NON BEARING SW WALLS, REMOVE PORTION OF EXLen% SUSPENDED CEIL8G, RE WALL 100 SUSPENDED CEUJ40. CHANGE SOME DOORS, ALL PER PLAN TAX ID. • 000480.005 BUILDINS 4 SITE STATISTICS OUILDNG CODE: IBC 2012 ZCNNG M-1 SEISMIC ZONE: ZONE 3 CONSTRUCTION TYPE: V -B SPRIKL.Ef7ED OCOEANCT GROUPS 8 45-1 ALLOWABLE BUILDI4G AREA: 1.6L0'IITED, 60' YARD ON ALL SIDES, AND HILLY SPRIKLERED AREA OF TENANT: 13828 SF AREA 0' REMODEL: 1,114 SF LEGAL SEPARATE PERMITS: PLUMB8NG WAG MODIFICATIONS ELECTRICAL SPRINCLER MODFICATI0N5 POR LEWIS C C DC31 POR OF C C LEWIS DONATION CLAIM NO 31 TOW FOR OF STEPHEN FOSTER D01441104 CLAIM NO 38 M SECTIONS 10, R 14 4 5 TIP 23 RANGE 4 - BMP BEARING 4440-01-05W 920.5F1 FROM A I'IOFIPIENNT AT PT Cr NT544 OF ONRVE ON CIL OF DWIAM04- RENTON »1CT10 4 RD BEM APPROX 1000 FT E 1 20 FT 5 Cr QUARTER CORNER BEIU.EEN SECTIONS 14 4 5 114 N 45-24-00 W 835 FT CNA LIE PLT 4 50 FT KELT aF GL OF DUIUA115l4-RINN104 41401104 F9 TAP BEARING N 81-44.55 E 19971 FT FR PONT Of CURVE ON CIL OF putuansw - Fa3NT0N JUNCTION FD SD PT O- C1R*E BEING APPROX 1200 FT 14 4 440 FT W Of QUARTER CCF3ER 8ETUEEI4 SECTIONS 14 1 5TH 540-36-00 W 20 FT TO NELY MGN OF RAU OF PIIGET Sato ELECTRIC RAILWAY TNN 45-24-00 W 9E025 FT 114 5 45-24-00 E 400 FT TN N 40-36-00 E 350 FT TO POB TNN 40.36-00 E 51270 FT 114 N 45-24-00 W 325 FT 1145 15-5-35 W OBI FT TN 14 45-24-00 W 61 FT 114 540-36-00 W 502J0 FT TAP BEARING N 49-24-00 W 40081 FR POB 114 5 49-24-00 E 400 FT TO POB -- AKA LOT 2 OF CTT Of 14514LA BDRY LIFE ADJ NO 91-4-8LA RECORDING NO 910523362 1 REVISIONS No changes shall be made to the scope of work Without of Tukwila Building Division. Yomr approval 'ice.. 's �_ n'"' VOTE: Revision: will require a new plan end may kic!ude additional plan review tees. 1 C ) ) SEPARATE PERMIT REQUIRED FOft 0 Mectanicat Cr at iffPiumg @Mas Piping tr.. of Tukwila t'I 7-4 .DIVISION U BUILDING PLAN SCALE1. 1"=30' CORRECj10N LTR#, A —REtlIEINED FOR CODE CO MPLIANCE h,ppROVED DEC 10 2013 b�-- \A L I G ty of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 4 2013 e ERMIT CENTER 1� A a 5 0 07 0 0 z CA 000 C) IPn CO ar fm(0 00 OA OA z ox 0. A" 1 is m • SD =1 EX ADA PATE P EX ADA ENTRANCE IID C NIGES INDICATED, THEY DO NOT INDICATE THE MEANS Oft METHOD OF CONSTRUCTION 9. ALL BUILDNG CONSTRUCTION TO BE N COMPLIANCE WITH ALL AM REQUIREMENTS AND NEEETAll BUILDING CODES HAVING JURISDICTION. 4. MODIFYE7OSTNG DEMSNG WALL BETWEEN TENANTS. EXTEND TO THE UNDERSIDE OF TIE DECICABOVE WITH SOUND ATTENUATION NSUATION FROM MP 70 BOTTOM AND CONSTRUCT TOM ET ODDE REQUIREMENT& i MODIFYEXISTIKG SEPARATION WALLS BETWEEN OFFICE SPACES AND WAREHOUSE SPACES EXTEND 70 THE UNE OF ME DECK ABOVE WITH SOUND ATTENUATION INSULATION FROM MP TO BOTTOM AND CONSTRUCT 7O MEET CODE RECUIRE IS 8. PROVIDE AND NSTALL PANIC BAR HARDWIRE ON EXTERIOR WAREHOUSE MIT DOORS. 7. CONTRACTOR 7OVERIFY THAT COSTING ELECTRIC OVERHEAD DOOR OPENERS FUNCTION PROPERLY, REPAL<UAQB/STAS NEEDED. B. WAREiOTSETOBEOPEN 70STRUCTURE ABOVE WITH 18'-0' MNMUOM HEIGHT CLEARANCE REQ A WAREHOUSE FLOOR S EXISTING SEALED CONCRETE FLOOR 7O BE SWEPT CLEAN AND CFOR ANY DEFECTS PRIOR TD OCCUPANCY. GTP BO CAGED OPiiOIYs 399 SF • IAS 21 OCC. I DOT \ALEHOUSE D'h 4,-0. Truck Well 9'-0' I 9'43" 7,-0, /4.40' lW®11 Ca NELMS 11111 COME PALM W,_8. z-_ HEN BOLLARDS, 6' DIA 6TEEL POST 4' Of, 3' BELOW, FLOOR PLAN: NEW SEE SIFT T -N FOR ROOM AND DOOR 804 pEEB CONCRETE RILED, WITH FOOTW, PAIN SAFETT ltrAm v1 , r r NORTH Yaw = -7 a b OG Nye- Grio Os (,rye = 1-Q7°' Os 4- 9.4° 9 9 4 EIDE LEG DOE • MUG MGM 12. PROVIDE AND INSTALLB'SOIANDBATTMINGFELAATION ABOVE NEW DRYWALL CE LA G AT WAREHOUSE LEi10E 19. INSPECT (Ly GAS RHE) MING LAMS REPAIVREPIACE OR ADJUST AS NEEDED. MOOD sITOREe AIE AOEaW1E 1b. RASHPATCH AND REPAIR ALL FLOLYSAND WALLSIWIBRE DAMAGE COSTS N PREPARATION TO RECEIVE NEW FINISHES. 18 REUSE DUS7NG REAV VED DOORS AND DOOR FRAMES WHERE POSSIBLE FOR ALL SINGLE DOORS I F THEY COMPLY WITH TEANTOUTLNESPECFICATIOVREQUIREMENTS OR MATCH BUILDING STANDARDS SUBJECT TO TENANTS APPROVAL OTHERWISE REF7r7SH DOORS AS NECESSARY OR REPLACE WITH NEW DOORS RIA ESANDHARDWARE AS SPECIFIED TO ACHIEVE UNIFORMITY. NEW DOORS SHALL WTCHBlELDIKG STI NMROAND BE FINISHED TO MATCH DOSING SURROUIDNG COMMONS. 17. PROVIDE AND RETAIL ALL APPLICABLE HARDWARE TO DOORS NLMCAT®AS HAVING WOK PROVIDE SEPARATE KEYING FOR THE OFFICE AND WAREHOUSE SPACES 0 N A COMMON MASTER KEY SYSTEM PROVDE 12)SETS OF KEYS TOEACH LOCKTOTENANT. EXISTING LOCK SETS TO BE RE4El'EDASNEEDED T-LOCKNDC47ESPRIVACY SET. 1! PROWDE AND INSTALL NEW VNYL TEE ROOTING N CORRIDOR 165, IMMENE 106` MENS 107, (AD)TE.LPHO E/DATA BOCAI 110. TRAINING ROOM 114 ROOM 117, AND WAREHOUSE OFFICE 118. PROVIDE AND NSTALL GWRETNG FOR ALL OTHER OFFICE AREA SPACES. TEWNT 70SEECTCOLORS NOR NEW NMI -BASE, VCT AND CARPET. WAREHOUSE FLOORINGSHALL RESEALED CONCRETE IWO 20. MODIFY, REPLACE AND SUPPLEMENT COSTINGHVACSYSTEM AS REQUIRED TO ACCOMMODATE NEW SPACE USAGE. ' f:L REDO ATENEPAP4FEPLACEAS ll QUTHLIT. PROVIDE AND NSTALL DOOR FRAME, AND HARDWARE AS SPECIFIED. HARDWARE TV SNITCH BUBD/NO STANDARD AND RAINES. MIN REGIONAL OFFICE 10.9, INTERIOR °FA E PART7TDN TO BE CENTERED ON EXTERIOR MOOR MUUON. mN OPEN OFFICE 101 AND Pim AREA 104A, PROVIDE WALL BLOCKING FOR FLAT SCREEN TV. 07IS TO PROVIDE WALL MOUNTED LCD SCREEN NMHDETAt6/SPECIFICATIONS. SEE SEPARATE GENERIC FLAT PANE. DSPLAY- STANDING MOUNTING DETAIL FOR C IVTERLNEH03IHTAND DIMENSIONS OF WALL BSOOONG. Fj C1 N MEWS ROOM 107, PROVIDE AND NSTALL (5)ADJUSTABLE PLASTIC LAIMNATE SHELVES WTTHA FINISHED EDGE FOR SUPPLIES SHELVING SHALL BE 21 DENY AND IIOIINTID ON METAL BRACKETS AND STANDARDS SPACED AT92'QC. MNNUM N COPY AREA 109, METALL TE W NT PROVIDED MAILBOX SLOTS. DMENSION S 70 BE FE ID VERIFY. TE DATAROOM 110, ASPECT OOSTMGSPLITACROOF LVOT FOR COOLING ONLY SIM WALL MOUNTED THERMOSTAT AT 11 AFF ON WALL REPANREPLACE AS NECESSARY. FROYDE AND NSTALL LOUVERED DOOR WPM MOIL LE AT COOT PILUS REGIONAL OFFIXE 111 AND WAREHOUSE OFRCE 118, PROVDEAND ANTALL 0-0' WIDE WIDOWS, SILL AND HEADER HEIGHTS TO MATCH EXISTING MINOR WIDOWS, M[QREL PRESSED SMEL WINDOW FAMES N WALLS INILSSOTHERWISE INDICATED. CGLAEEWIDOWSTYPICAL. REGIONAL OFFICE 111 AND WAREIDtSE O/E 114 AND INSTALL AEW BENDS ON INTERIOR WIDOWS. NEW BUNDS TO MATCH ENVINGBLOCS. ®N REGCNAL OFFICE 111, PURR OUT WAILS. III IE; ,,, N OPEN OFFICE 119, PROVIDE AND INSTALL NEW CASED OPEN NEL N TRANING ROOM 116, AND CONFERENCE ROOM 116, PROVIDE MOTOR® RECESSES CEILING MOUNTED ELECTRONIC PROJECTION WREN (71r7701LS TO PROVIDE CE7.NO MOUNTED PRQECTORiSAS INDICATED ON PLAN VT1-4W7IHDETA8.SISPECSIC.ATNOM IAIIDLORDAND RAL CONTRACTOR TONSTALLNCEILI GPROECTIONSCREEN AND OTS PROWDED PROJECTOR N TINNING ROOM 114 AND CONE ROOM 110. FROVDEAND INSTALL ACEIAEGMOUNTEDPROJECTION SYSTEM SUSPENDED OVEN TABLE N BREAK ROOM 117, PROVIDE AND INSTALL WATER HOOK UPS FOR CE DISPENSER COFFEE MILER AND WATER COOLER SHUTOFF VALVE MR COFFEE RAKER TO BE ACCESSIBLE ROOM COUNTER TOP. PROVIDE RATED 0008 WITH ASTRAGAL NTO QFFKE SPACES, DOOR FRAEEAND HARDWARE DOORS WILL NEED TO BE TIED NTD THE RREAND SECUIVTY ALARM SYSTEM AND HAVE 127(12' VISION PANEL& OIL E ICT RAI®. DOOR ED? RCMP WAREHOUSE 118/IBOVEEXISTING SLOP MIK RROVDE AND NSTALL WALL SPLASH PANS AND 2 TIERS OF 1411 X SOW SHELVING AIR QUALITY AND ENERGY CODE These plans comply with the 2012 IMC including Amendments Sec 403 Mechanical Ventilation and Washington State Energy Code. NECESSARY. 25. REPLACE ANY AGED ORDAMAGED CEDING TILES AS NECESSARY CEILING TILE F I TO BE CONSISTENT THROUGHOUT. 29. RELOCATE AND ADD HVAC DIRGSFRSRETURN GRILLS, SPRNI¢ER HEADS ETC. FOR COMPLETE AND COORDS ATED NSTALLA7DNL ALL WORK SHALL ATEETOUTLNE PI MNCESPECFTGITO/ISANDALLAPPLICABLECODE& 2Z EXISTING LIGHT FIXTURES THROUGH OUT ',TENOR BUILDING AND LOADING DOCK AREAS MBE N GOOD WURI(I COMMON. ADLIRIPALRMEPLACERELOCATE OR ADJUST AS NEEDED TO ACCOMMODATE NEW LAYOUT AND MEET ALL APPLICABLE CODE REQUIREMENTS AS WELL AS SPECIFICATIONS. RELAMPALL FDRURESAND REPLACE FAULTY BALLASTS WHERE REQUIRED. 28. ALL ELECTRICAL, YEOMMICAL, PLUMING, AND SPRINKLER SYSTEMS TO BE CODE COMPLMNT AND N GOOD WORMS ORDER PRIOR TO OCCUPANCY. ?er aQvc,41& ECC ` Ad UM( IBE E FOR COMPLIAN �E APPROVED Na" ,,.. • ,, . ,2 ..•. 1 23 noncerfirstaiuT City of Tukwila BUILDING DIVISION ALL. ELEGTWICAL, MECHANICAL PLU'l384 AND SPRIRLER STSTEI6, TO 8E CODE CO1PLL8 AND 14 GOOD SMOG ORDER PRIOR TO COOPNCT. MOW( ROOF ? ®'ERNE AHD FLASNRIG FAR PEW HVAC WI18, ROOF STRICTURE TO REMAIL RECEIVED CITY OF TUKWILA DEC 0 4 2013 PERMIT CENTER i a 1 V2 0 0 Reg Oils Elevator Company ny 33E11S Oman alleA TunkuYia,, Mao sffiIlso GaJz e earth feet meters 77'7)) =•Mil %.JVub'1G 1viapa Goggle Hayward `-7' Baker S I l 2th St ' Q, 5 112th St Riverside Iiesidences N S115thSt 5 1131h51 `) Duwamish Hill Preserve 4Dth-r S 114th S 115th lP Careen rliy t[ed Blue Sky Integrated •,o "Techs Green I; we, 11n4 Legacy Fl. Group \\,,7 all's , , Camera & BPI Jackson Dean Construction S 1 16th St n co 5 117th St Sears Home ■; Improvement Products 5 117th PI S' o o'�.Sahale ,•-- vSnacks ft) Volt Workforce .. a, Solutions 5 120th Pt King County Petro t South Base m ©2213 Google - Map data 02013 Googl fl 33.15'iS •1161h Sf;;T`ukwila, WF, 98168',,�OSA 0 1' ` D 1, Google :ea r,th Google earth feet meters https://maps.google.com/?t=h&ie=UTF8&11=47.498575,-122.289612&spn=0.006292,0.011147&z=17&vpsrc=6&ei=Mm5hUpebEIGfiAKIoIHYCw&pw=2 1000 300 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 10 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 3 0 2013 PERMIT CENTER 10/18/2013 2012 Washin•ton State Ener. Code Com.11ance Forms for Commercial Grou. R1 and > 3 sto R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Farms for Convnercial, Group R1, and > 3 story R2 & R3 Revised June 2013 Project Info FILE COPY ..�. m I s Proiec Address 0 . 5 -4,. UT'— Date /0 .,;is,.... l �'� ° S ° ` For Building Dept. Use / qq f tL'1" 1 I u't�► i i .� Applicant Name: �C-rtxr(. +4_,1 e m, I. heLtl.i 0, .2.(luta Applicant Address: get q l t , ( ("r `•t, .A ) , I,� F(i Applicant Phone: /j 573 -��. 3(., "" 7 'f7_S qt d ._ Project Description Briefly descrbe mechanical system type and features. Includes Plans _ .� (��( ` ] Rof-{-,-10 ' J'epl ttu +( Le )ev t s l+VA-c Include documentation requiring compliance wdh commissioning provisions per Section C408. Compliance Option mple System Oomplex System Oystems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model Na' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception° Heat Recovery Y/N / R 1h 4l . rc o) t 5 _ri 1 ''')-r� ntita144a-A 3 f kTiit I,( RICA An -7/ -13A -{,e) Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSAcfm or Econo? Input Btuh Output Btuh Efficiency' Heat Recovery Y/N I RIUe (1[.1 Jo & 4 -re D CI ° 5 (aatr« 2A 1-rt,1 t r `I -t; rC D> 4 t:, .3 tNciA c i ti -n NAM -AG i Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location d Service A- . Service Water Heating Equipment Schedule Equip. Equip ID Type Brand Nam& Model Na' Input Capacity Sub - Category EF' Location of Service /vr +If availabl • Systems (b....,6' 1�f�applicable. 97-24:14°‘'s.'7 tCE APPROVED DEC 1 Q 2013 City of Tukwila BUILDING DIVISION .2.3(1)Athru C403.2.3(8). 3 If required. 4 COP, HSPF, Combustion Efficiency, e (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception 7 Efficiency Factor per Table C404.2. AFIVED P NJKWILA OCT 302013 PERMIT CENTER 1 Mechanical Permit Plans Checklist - Page 1 of 3 201 Washington State Kb, CodeConpiance orris or ►,rrrnerdal,Group-1,and> -stay-&-c MECH-CHK -- isedJune -,1 p ProjedAddress 33 JS //4tr c f- '�vk La"IA . f, ja • G1 ti it`s V Date JO, -A,3-.' / en prier M The following information is necessary to check a mechanical permit application for commeraal provision compliance with the 2012 WSEC. / %;i NOTE: Define print area In Excel prior to printing MECH-CHK pages.) "[. j.j 1]` 1 C t, eial Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes, e GENERAL PROVISIONS Equipment Sizing 8 Performance U/ni C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 040322 Equipment and system siting Output capadry of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC 1 C403.2.3 & C403.2.32 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment ✓ C4032.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except 1 C4032.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) i ' V C403.2.10.3 & C403.2.13 Fractional h fan motors p Indicate fan motors 1/12 to 1 hpare ECM t ype or meet minimum efficiency req. C403.2.3 Maximum air cooled chiller capacity Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N 4- 0403.2.1 Non-standard water-cooled chilers Full -load and NPLV valuesfor water-cooled centrifugal chiller adjusted for non - standard operational conditions N///�� A_ -7A 0403.2.12.1.2 Centrifugal fan cooling towers Large capadty cooling towers with centrfugal fans) meet efficiency requirements for a>oal fan open dreuit cooling towers 111 - / 0403.23 Forced air furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss N J^ hList C403.2.3.3 Packaged electric heating/cooling equipment Listequipment required to be heat pumps on schedule //(/ 04032.3.4 Humidification method of humidification (note requirements for systems with economizer HVAC System Controls 8 Criteria C4032.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter ))�systems i / //)r rv,li C403.2.4.1.1 heat Heat pump supplementary Indicate staged heating (compression/supplemental) & outdoor lock -out temp vAutomatic C4032.4.2 Setpointoverlap(deadband) Indicate 5°F deadband minimum for systems controlling both heating &cooling ,v,---"- C403.2.4.3 setback and shutdown Indicate zone t -stat controls with required automatic setback & manual override C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions �` 0402.4.52 & 04032.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions taken) /V C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls 1 C4032.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions / 41/ 04032 A.6 Combustion heating Indicate modulating or staged control NC4032.4.7 a Group R1 hoteVmotel systems Indicate method for guest room automatic setback & set-up of 5°F minimum 1 0403.2.4.8 /gGroup R21123 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Aff/ C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV , /t// �V C4032.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; orrn alternate means provided to automatically reduce OSAwhen partially occupied C403.2.5.3 Enclosed loading dock/parlang garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method //' tv (conditioning C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and method NIndicate 0403.2.5.42 Laboratoryexhaustsystems lab exhaust systems requiring heat recovery, method & efficiency, or alternative method taken (VAV, semi -conditioned makeup, or CERM calculation) I r +a .C4032.6.4, ^,s sy• Energy recovery - ventilation s ,t_ems Indicate ventilationsystems requiring ER, method &efficiency; W 9 note exceptions , 7 d -; of ' ' r,t ° h`:y.J�U\ ,'1,b.; C403.2.6.2 systemsEnergyrecovery - condensate Indicate on-site steam heating systems requiring energy recovery d l'-').:', p iFi;tb`t< 4if: 1J Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012Wa "n.on ate erg odeConyfance")oms orC�omrner•al, roup -1,and> story- & - ° sed une:i13 ! /y a Project Address '�3 16 S • ! l(; 7^3 1 : �vV L i It, )) t&) A. IOate ft'� /A ---i The following information is necessary to check a mechanical permit application for cdmmeraal provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes 1 . rnii: .iilin a 'l HVAC System Controls & Criteria, Continued '!I "( 04032.12 finable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) / U%/ 0403.2.12.1 Variabl+v flow control -cooling towers towers Indicate Indicate cooling tower fans requiring variable flow control and method /! r N 0403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken j C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N/A C403.2.4.10 DDC systemcapablities Identify all DDC system input/output control points and indicate capability for trending and demand response setpointadjustment Ducting Systems / y C403.2.7.1& C4032.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements C403.2.7.3.1-3 Duct pressure dassifications Identify location of low, medium and high pressure ductwork on plans J0403.2.7.33 High pressure dud leakage test Indicate high jpressure duct leakage testing requirements on plans; provide test results to urisdiction when completed V� C403.2.7.1 /2 Duct insulation Indicate R -value of insulation on ductwork Piping Systems 64, C403.2.8 Piping insulation Indicate R -value of insulation on piping 4//4 04032.8.1 weatherPiping insular on exposed to Indicate method of protection from damage/degredation 701,I;1IIili: Qualifying Systems 4' % J 0403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heatinglcooling C403.3 Qualifying 2 -pipe heating systems Verify 2 -pipe heating -only system does not exceed capacity limits Aft., C403.32 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception 0403.3.1.13 Air etrconomizerols high hind con Indicate high limit shut-off control method per Table 0403.3.1.1.3(2) C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems wall capacity > 65,000 btuh f I4 4,f/4 f 7 C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to complywith exception(s) =;tilt-uiii 110 Complex4,System Economizers Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. ivC403.4.1 /� C403A.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation /r'I %rt r 0403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems //� N Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db145°F wb OSA i840403.4.1.2 Water economizer maximum pressure drop Indicate precooking coils and heat exchangers do not exceed pressure drop limit /� J�/}- C403.3.1 Air economizer exceptions Indicate eligible exceptions) taken and provisions to complywith exceptions) Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK 2012 Washington State Enecoy C ode Compliance Forma br Commercial, Group R1, and 3 story R241 R3 Revised June 2013 Project Address '!� i $ /j(,77^ Q- U k �i I W /4 .- Date i 3 5 i �� I ��., z�-13 The following information is necessary to check a mechanical permit application for comneraal provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHKpages. APPloabitity (yes,to,na) Code Section Code Provision Information Required Location on Plans Building Department Notes _❑ , n i t ei,i i l l i. ❑,�, J',i-J=Sj Specific System Requirements 471 C403.42 & C4032.12 Variable fbw control - fans Indicate fans requiring variable flow control and method 1 A/% C403.42.1 VAVfan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major dud Mantic i/4— �� C403.4 2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure /l/ N//T t((((zones C403.4.5 VAV systems serving multi- Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken C403.45.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads Ay/� I 0403.4 Large cepadtycooling systems Indicate method of multi -stage or variable control for building cooling system capacity> 300 tons 44C403.4.7 Hot gas bypass limitation Indicate cooling equipment unbading or capacity modulation method A/74.--. C403.4.3 Large capacity boier systems Indicate multi -stage or modulating burner for single boilers > 500,000 btuh IV4— C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers Afi� 0403.4.3.5 Chiller / boiler plant pump isolation Indicate capabfity to automatically reduce overall plant flow and shut-off flow through chilers & boilers when not i1 use i `+ it,/ C403.4.3.6 42 & C403. Variable fbw control - pumps Indicate pumps requiring variable flow control & method / / j^/J� 1V 0&4032.12.10403.44 Vtowariableers fbw control - cooling Indicate cooling tower fans requiring variable flow control and method 41/7 0403.4.3.4 Hydromcsystem part load controls Indicate heatng&chilled water systems have the capabidytoautomatically reset supply water temp AND reduce flow by 1350% for systems > 300,000 btuh A f 7 C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling node scheduling and changeover temperature range 0403.4.3.3.1 Water bop heat pump - deadband Indicate capabiityofcentral equipment toprwidemn.20'Fwater supply temp deadband between heat rejection and heat addiion modes �� 0403.43.3 pump - Water bop heat pump - heat rejection Provide heat exchanger that separates cooingtower and heat pump loop in ClimateZone5 �/ 0403.4.3 3.3 Water bop heat pump - isolation Indicate 2 -way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp VC403.4.6art water heat Indicate system provided to pre -heat service water and efficiency 0403.5 Cooler/freezer-anti-sweat heaters Indicate ovist &control method for walk in cooler/freezer door anti.sweat heaters PA C403.5 ! 6 Cooler /freezer - evaporator end condenser fans Indicate motor type for evaporator and condenser fans < 1 hp =EDE ui 11 ,uM=0 Service Water Systems W/ !� C4042 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) 1/4_ C404.3 Temperature controls Indicate temperature controls have required setpoint capability 00404.4 Neat traps Indicate piping connected to equipment have heat traps on supply & discharge C404.5 Insulation under water heater Indicate R-10 insulation under tank RLJ / 04046 Service water piping insulation Indicate R -value of insulation on piping; note exceptions taken �/ C404.7 / 8 systems and heat trCiace arlationshut-0ti indicate shut-off cepabiity based on occupancy and periods of limited demand 0404 9 Group R-2 service hot water meters indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas A/1 1111 C404.10.1 Pool heatng equip min. ethciency Provide equipment schedule or complete MECHSUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters a 4 COP �- 0404.10.1 12 Pool heater on !off controls Indicate automatic on/off control based on scheduling & accessble on/off switch on heater that operates independent of thermostat setting; or exception taken 1 0404.10.3 Pool covers Indicete vapor retardant ewer and insulation rating as required 1 / 0404.10.3 Pool asserh�y insulation Indicate ratng ()frets. f insulat on on sides and bosom of pools heated W > 90°F v/ C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use CT ENGINEERING INC. FILE COPY Permit No. — STRUCTURAL CALCULATIONS Replacement of 4 RTU 3315 S. 116 Tukwila, WA Contractor: Precision Builders, INC. 180 Nickerson St. Suite 302 Seattle, WA 98109 (206)285-4512(V) (206) 285-0618(F) Scope of Work: Replace 4 roof top mechanical units. The new units are the same size and will re -use the existing curbs. Make a site visit to verify that existing framing for the unit supports has been installed. Code: Loads: IBC Snow Units Seismic REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 0 2013 City of Tukwila BUILDING DIVISION Structural Engineers 2012 Edition 25 PSF 3 -Ton =543#; 4 -Ton = 597#; 5- Ton = 629#; 6 -Ton = 710# SDS= 1.00 ECEIVED Y OF TUKWILA 10/29/2013 DEC 0 4 2013 PERMIT CENTER CORRECTION Mf2ri1LTR#0 C T ENGINEERING project n.Tv — o 114- 1' Date: 4Diz`il�3 Client: Rage Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285.4512 RAX: (206) 285-0618 EPL4 c. �'' V S. n rt int 1 Lt_ ., t cw..0 u`n 47S l tii>4 11,a !b: stT'G- \Ma 14.1-1Z Nlotcl 15 �S tN •ikooe- rho itu ;rt ti, . i rz s: +� t3 x..etey :Li. stiff s'T��^e1: d' A- - uKir .. 1yu.l,11 on./x. Wit, a►v� "�bt t`W j 'a tou � r 1044.E.. k b , ` . ;cant Toe; . Puruakt. Ati.r "C td a7t,.6 tm i; -a41 f= 2b ok 1 : 4x (.SM • tem c bC) -FRE. .3Nit-Te4 TIVE 'Avv1E Loft - 1.4•1_1) -roc ‘",teetkr7• ►S btrAncY2 Z1. •51z timer t9N;17 S'p c�c�1.:111q L) 1411,S; RTS. I 1.-Tokt 517. gro* Z . 5 . raµ 629 RI -014' 3 . Cs,- TOK1 "1.12'14' izeu ' 24, 3-701J StatAtc- S%= rl:41 . Sr V ,S. . .41 %.b To Se 1 L b Sat Igo SDk.: S14- ,:5 \NI p ., �sI Ac. Pis -0 tip_Tarv:. Structural Engineers ga,: , 2 h. • FP = 2 S_' a -Soca 6N%c CLtPt• TWe. T IEAc!ii- 6_4P Tri Uru.Ii . �. c 2S 'soar a -e = 2'51:%c1°-- T� tai' _ b •o i L TN-€. L0411 • C T ENGINEERING 1 N C. Project'. -9•.-9•47L)- ' 'b1'S So , MDT' .`C.vVAt11ub Date: 01211 -6 Client Page Number: 180 Nickerson St. Suite :102 Seattle, WA 981(19 (206) 285-4512 PAX: (206) 285-0618 1�btM1ti1 C.. 4-0 -71; C L.l ' •l IVB 154. Nc:,Lo 1kRak..tc urui'� Tc . atP SI} 62'• • SZ.CD Tota. 901— I01'Z1 eb*-- •C.A. LPL %. M • • .0(DJ o ). gquuw•, -LLP T(, Cut213 LInQ0 Q o 024 .1, co R lug CZE z� %. .� Inl.usscvi�,>..CL,pc. Ih+. rot -4- oui (?a,t; = ��� ii 2SO ' . OIC-. cAtawn-9•�.tny' 0 M -?..so (60 1l-0 5:SZ5 (Z— 1l2 C l 15 tab+ u PSIPT C. -+1.LL N.c-i l.P c ) elbt1094A Structural Engineers C T ENGINEERING 1NC, Project: 1270 — v ‘1, L7" TO L-V^LAL14 Client: Date' V J Zg) 13 Page Number: ` 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: (206) 285-0618 CUP (2. ate- Low, %% ti . To-fbt-e • ► t�t� CLAP• - Structural Engineers REVIEWED FOR CODE COMPLIANCE APPROVED DEC 1 o 2013 City of Tukwila BUILDING DIVISION FILE COPY United Technologies SUBMITTAL Project -Untitled 18 Date Wednesday, October 23, 2013 RECEIVED CITY OF TUKWILA DEC 0 4 2013 PERMIT CENTER CORRECTION I_TR# Project:-Untitledl8 Prepared By: Table Of Contents 10/23/2013 04:30PM 01 3 Unit Report 4 Certified Drawing 5 Performance Summary 7 02 10 Unit Report 11 Certified Drawing 12 Performance Summary 14 03 17 Unit Report 18 Certified Drawing.... _ 19 Performance Summary 21 02A. 24 Unit Report- 25 Certified Drawing. 26 Performance Summary 27 Packaged Rooftop Builder 1.39a Page 2 of 29 Project:-Untitledl8 Prepared By: 01 10/23/2013 04:30PM 01 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39a Page 3 of 29 Project:-Untitledl8 Prepared By: Unit Report For 01 10/23/2013 04:30PM Unit Parameters Unit Model. 48TCDA05A2A6-0A0A0 Unit Size. 05 (4 Tons) Volts -Phase -Hertz. 460-3-60 Heating Type* Gas Duct Cfg. Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size. 112 Condensate Drain Line Size. 3/4 Return Air Filter Type' Throwaway Return Air Filter Quantity. 2 Return Air Filter Size* 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length. 6' 2375" Unit Width 3' 8" Unit Height: 2' 9.375" Total Operating Weight. 547 Ib *`* Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA05A2A6-0A0A0 Rooftop Unit 1 Packaged Rooftop Builder 1.39a Page 4 of 29 Project:—Untitledl8 Prepared By: Certified Drawing for 01 10/23/2013 04:30PM 151(0: 1. 1111N510080A(1 YILl1YE1EI5!(0(1510R5 2. S CENTER Of GRAVITY UNIT 4611 -AOA 33 Le 18411 14121 4.Tc-ADI 33 5/8 18411 14111 1111 41 .406 33 316 (8411 14 ue 11111 4510 -AOT i330 tem 11 118 11111 1518 1111 LECTRICAI 0(5C0NNEC1 LocATIoN 1I 111111 022)0X31 FACTOR! INSTALLED CONVENIENCE OUTLET 1.1/5 14841 6.5/6 1661 3-314 1151 46 3/4 men LEFT `4-- 12 1/4 18181 0 *8(155 2.8. eN 1111 T(ll/800011E5 1184131. 4N 533/8 18181 .7 ECONOMIZER X000 101110NAL1 11 14011 l 16-I lie I 1 1 11511 !11-11' 14-61' 2.611 . 14111 Upl 111 SEONSEACHART 16311 -- 23.5/5 — RETURN RIA I 10.1/e1 (211 4411 21.311 (0 -I/O 11131 E1 11 SUPPI! 8 • [ ALT. CONDENSATE DRAIN OPENIND IN DASEP(5AN 1.3/4 14511 54P10! 11 RETURN AIR 105 x005 TOP 1.611 1 1-3/8511 1115 1'-112 roc 1 OPTIONAL FAC ALLED DISCONNECT 1011101 001 ACCESS PANEL � . �gIR1 tli� INDOOR ROPER ACCESS �XARDLE j00 CONOUl1 SIZE I 00 4. HANKS Hp 0-3/5 30 1/8 1213) 17641 II I FRONT CONNECTION SIZES 1 3/1. 1351 DIA FIELD PONE' 5UPPLI HOLE 0' 1501 DIA 208(8 SUPPLY ANOC(041 1 SIA' 1011 DIA GAUGE ACCESS PLUG 2/5' 1221 DIA FIELD 10x1500 mom HOLE 3/4•.14 NPT CONDENSATE DRAIN 612'.14 NIT GAL CONNECTION 1 lli ' 1141 DIA POND SUPPLY 011001.0111 1x50.1NDIASE CNAR1 THESE HOLES 1[4818[5 f0R USE 18e1028000(001, 00(401 25-i/e 1101/0 ,Ip } THREADED 818E 8(0'0 HOLE rO CONOUl1 SIZE DSE SIZES 1145.1 • Hp ACC. 7/6' (55.21 8 1/5• Iry 1/e4 122.2) I • 3/4. 1101.0031 PORI 1 lie. 126.41 (*8 10031 1/2• FPI GAS 1 1/16. 130.10 (0R •I885-IUE-IAIE5AN• PAf10R! 0111011. 01111845 FOR ONLY 1.1, 5 I ARE PR001000 ' SELECT EITHER 3/4. 01 212• FOR 108(8. DEPENDING OP 818E SPIE (8811 PROTI010 314. 0511 x88 CURB " RANGE & 1113X0. 0 SID. CONDENSATE DRAIN 25-i/e 1101/0 ,Ip } ti 1/-111 —� n1111'411I/l!11 11415 rO ti `i 58808(12(0 REIIEf FLOP MCI tat 11-24-08 WAKENS 09-29-08 48TC 04-01 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 4819500993 5.0 Packaged Rooftop Builder 1.39a Page 5 of 29 Project:—Untitledl8 Prepared By: Certified Drawing for 01 10/23/2013 04:30PM UNIT 535. UNIT WEIGHT CORNEA 0EIGRI 761 C00NE6 9E101 181 CORNEA WEIGHT ICI CORNEA WEIGHT 101 C G. NE IGHI LBS. NG. LBS. 116. LBS. 36. LBS. 3G. IBS. A6. N 2 2 4311.804 483 211 III 50 125 57 131 51 111 53 31 13111 23 15841 11 3/8 (4111 4113105 531 244 124 5/ 131 13 145 11 121 51 31 16911 23 (5011 13 14321 411(.406 561 258 131 51 147 67 154 10 131 62 31 11911 23 (5841 11 1/4 (4381 1614.461 112 211 151 68 161 16 116 80 151 71 31 11911 23 (5841 20 1/8 15111 CORNER A TOP FRONT 0 UNITED T104I0L0G1(5 4 3IAp4. 0031I(0 15551 EIMIREWEEmo CORNER B CORNER C SAM 2 0E 2 UTE 11-24-08 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 4814500993 5.0 Packaged Rooftop Builder 1.39a Page 6 of 29 Project:—Untitledl8 Prepared By: Performance Summary For 01 10/23/2013 04:30PM Part Num ber:48TCDA05A2A6-0A0A0 ARI SEER. 13.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width. 44.0 in Unit Height. 33.4 in Operating Weight Base Unit Weight. 537 Ib Medium Static Option. 10 Ib Total Operating Weight 547 Ib Unit Unit Voltage -Phase -Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type. Belt Actual Airflow. 1600 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB- 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB. 60.2 F Evaporator Leaving Air WB. 57.7 F Evaporator Leaving Air Enthalpy 24.83 BTU/Ib Gross Cooling Capacity 47.60 MBH Gross Sensible Capacity. 34.22 MBH Compressor Power Input. 3.31 kW Coil Bypass Factor 0.246 Heating Performance Heating Airflow. 1600 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 104.1 F Gas Input Capacity. 72.0 MBH Gas Heating Capacity 59.00 MBH Temperature Rise. 34.1 F Supply Fan External Static Pressure. 1.00 in wg Options / Accessories Static Pressure Economizer 0.07 in wg Total External Static. 1.07 in wg Fan RPM. 1164 Fan Power 1.13 BHP NOTE. Selected IFM RPM Range: 770 -1175 Electrical Data (Before July 30, 2012) Minimum Voltage. 414 Maximum Voltage- 506 Compressor RLA. 6.2 Compressor LRA. 41 Outdoor Fan Motor Qty• 1 Outdoor Fan FLA (ea). 08 Indoor Fan Motor Type. MED Indoor Fan Motor FLA 2.1 Packaged Rooftop Builder 1.39a Page 7 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 01 10/23/2013 04:30PM Combustion Fan Motor FLA (ea). 0.24 Power Supply MCA. 10.7 Power Supply MOCP (Fuse or HACR). 15 Min. Unit Disconnect FLA. 10 49 None Min. Unit Disconnect LRA. Electrical Convenience Outlet.. Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA. 2.6 Power Supply MCA:. 12 Power Supply MOCP. 15 Disconnect Size FLA. 11 Disconnect Size LRA' 52 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 88.1 88.0 90.9 125 Hz 82.7 79.8 84.6 250 Hz 74.7 66.4 79.5 500 Hz 70.4 64.0 77.9 1000 Hz 66.9 63.2 76.5 2000 Hz 61.5 57.2 71.1 4000 Hz 63.2 52.8 66.9 8000 Hz 58.6 45.6 62.5 A -Weighted 74.0 69.4 81.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground' 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction' 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.39a Page 8 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 01 10/23/2013 04:30PM Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 90.9 84.6 79.5 77.9 76.5 71.1 66.9 62.5 92.4 Lw B 64.7 68.5 70.9 74.7 76.5 72.3 67.9 61.4 80.8 LwA C 58.5 52.2 47.1 45.5 44.1 38.7 34.5 30.1 60.0 Lp D 32.3 36.1 38.5 42.3 44.1 39.9 35.5 29.0 48.4 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 20 18 16 04 cr co co FanCurve -1103;PM 1 ` �K13x1RFM - 900RPM \\ \ N. - \ \.N - 70oMM \`, ,\\ \\ N. ,O.SOBFP" J a3 as 09 12 15 18 Airtlow(CFM-thousands) RPM=1164 BHP=1.13 Maximum RPM=1175 Maximum BHP=2.40 Note: Pleasecontactapplicationengineeringforselectionsoutsidetlheshadedregion. SC -System Curve RP -Rated Point 21 24 Packaged Rooftop Builder 1.39a Page 9 of 29 Project: -Untitledl8 Prepared By: 02 10/23/2013 04:30PM 02 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39a Page 10 of 29 Project:—Untitledl8 Prepared By: Unit Report For 02 10/23/2013 04:30PM Unit Parameters Unit Model. 48TCDA06A2A6-0A0A0 Unit Size: 06 (5 Tons) Volts -Phase -Hertz. 460-3-60 Heating Type. Gas Duct Cfg. Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 2 Return Air Filter Size. 16 x 25 x 2 Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length. 6' 2.375" Unit Width: 3' 8" Unit Height. 2' 9375" *** Total Operating Weight. 579 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA06A2A6-0A0A0 Rooftop Unit 1 Packaged Rooftop Builder 1.39a Page 11 of 29 Project:—Untitledl6 Prepared By: Certified Drawing for 02 10/23/2013 04:30PM NOM: 0. 111"11101; 1IL1IYE1[*SDIMLNSIg15 2. B CENTER Cf 0843017 5. DI8001[0N Or AIR FLOW UNIT 481E -A04 15 5/m1 10 1e 5/8 14121 4810.405 31 300 [8411 74 008 13111 48Tc.A06 11 98 10411 14 008 [3171 4010-401 41 3/8 (10011 14 1/e 13111 `7-- 32 I/4 14181 1 4-5/8 11181 LEC101CRL DISCONNECT LOCAl10N OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET It /2 14041 341/4 1000 46 3/4 LEFT SEE 1HRU TNEJ 0000/401 31 313 [8481 0 UNITED cECHN0.06110 004[041.0 comp gun ECONOMIZER H002 [OPTIONAL, -- 25 5151106 110191111 AIR 10111/8 41 12 C AIT. — CONDENSATE DRAIN OPENING IN BASEPAN 14 TOP 17315 14511 SUPPLY R 44- RETURN RIR 12.1/1"-.47--.— 14/I [851 13471 •� 1411/1 -� 14101 OPTIONAL FACTORY INiONN[CTr Al lfD DI SC 008100' 501 ACCESS PANEL Iii:S. THREADED ' • 5. [NOOOR BLOWER ACCESS 480L( goo 0000011 511E is : OO HANDLE 84/e 30 lie 12131 11141 74 la 116441 FRONT CONNECTION SIZES 1 113' 1551 DIA FIELD POWER SUPPLY HOLE 2. 1001 DEA POPEA SUPPLY KNOCKOUT 1 3/4' 1511 GIA GAUGE ACCESS PLUG 101' [211 01A FIELD CONTROL MIRING HOLE 3/4..14 0P1 CONDENSATE DRAIN 1/2'-14 NPr 6A5 CONNECTION 1 111 ' 1441 DIA POWER SUPPL1 25008.051 7NRU-101-BA E CHAR THESE HOLES REQUIRED f0R USE CR0INPWR00IA01, 603401 THREADED WIRE RE0'0 NOLL 0000011 511E USE 51103 1851.1 1/0' Acc, 718' 122.21 l 111' 241 lie- 122.21 I . 1/4' 1001.6611 POWER 1 1/8. 100.41 Z.. 10011 112' EFT 6A5 1 1/11' 110.01 F00 •0080-114E.5ASE AN. FACTOR, OPTION. FITTINGS 701 ONLY 0.1, A 1 ARE P80410ED ' SELECT EITHER 314. OR 1/2' FOR P0315. DEFENDING OP WIRE SIZE .. 40011 PROVIDES 3/4• PPT 1x16 CURB FLANGE 1 FITTING. 1041/2 11111 [321 ILTER 126114/0 11 [1011 21 314 11411 31 004 11131 SUPPLY AIR RETY80 RIGHT AIA BAR0IETRIC RELIEF FLOP 10F2 Uri 11-24-08 WKWINS 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.39a Page 12 of 29 Project:-Untitledl8 Prepared By: Certified Drawing for 02 10/23/2013 04:30PM 0111 SAO. OMIT WEIGHT CORNER 60)641 161 COAXER 6016x1 10) CORNER KIM ICI COAXER 11(16117 10) C G, xF IGx1 LBS. AG. LBS. AG. LES. AG. L85. H. LBS. 46. 6 5 I 1650-101 183 219 111 50 125 51 131 59 111 53 38 19111 23 15861 16 3/8 11161 131[•405 531 211 121 36 139 63 115 66 121 5/ 39 (081) 23 (5811 11 11321 1810-106 368 251 131 59 111 61 151 10 131 62 38 (1011 23 (5813 17 1/1 11381 1850-101 653 301 150 68 169 76 116 00 151 11 31 (991) 23 (5841 20 I/O 15111 CORNER A TOP W00 I •i i'7 : 00 0 GMITED ases TECHNOLOGIES 0431 ¢.NV CARRIER tuts CORNER B CORNER C FRONT 2002 11-24-08 WKKOU 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 51.80 Packaged Rooftop Builder 1.39a Page 13 of 29 Project:—Untitledl8 Prepared By: Performance Summary For 02 10/23/2013 04:30PM Part Number:48TCDA06A2A6-0A0A0 ARI SEER. 13.00 Base Unit Dimensions Unit Length. 74.4 in Unit Width. 44.0 in Unit Height* 33.4 in Operating Weight Base Unit Weight 569 Ib Medium Static Option. 10 Ib Total Operating Weight 579 Ib Unit Unit Voltage -Phase -Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type• Belt Actual Airflow 2000 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy. 31.44 BTU/Ib Evaporator Leaving Air DB• 57.9 F Evaporator Leaving Air WB. 57.3 F Evaporator Leaving Air Enthalpy 24.56 BTU/Ib Gross Cooling Capacity 61.90 MBH Gross Sensible Capacity. 47.70 MBH Compressor Power Input 4.43 kW Coil Bypass Factor 0.055 Heating Performance Heating Airflow 2000 CFM Entering Air Temp. 70.0 F Leaving Air Temp• 97.3 F Gas Input Capacity. 72.0 MBH Gas Heating Capacity' 59.00 MBH Temperature Rise. 27.3 F Supply Fan External Static Pressure. 1.00 in wg Options / Accessories Static Pressure Economizer 0.12 in wg Total External Static. 1.12 in wg Fan RPM• 1442 Fan Power 1.64 BHP NOTE• Selected IFM RPM Range: 1035 -1466 Electrical Data (Before July 30, 2012) Minimum Voltage 414 Maximum Voltage 506 Compressor RLA. 7.7 Compressor LRA• 52 Outdoor Fan Motor Qty 1 Outdoor Fan FLA (ea)• 0.8 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 2.6 Packaged Rooftop Builder 1.39a Page 14 of 29 Project:-Untitled18 Prepared By: Performance Summary For 02 10/23/2013 04:30PM Combustion Fan Motor FLA (ea). 024 Power Supply MCA• 13 Power Supply MOCP (Fuse or HACR). 20 Min. Unit Disconnect FLA. 13 Min. Unit Disconnect LRA. 69 Electrical Convenience Outlet. None Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA. 3.4 Power Supply MCA. 14 Power Supply MOCP. 20 Disconnect Size FLA. 14 Disconnect Size LRA. 82 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 89.6 88.5 84.0 125 Hz 84.6 81.9 82.2 250 Hz 78.1 69.3 76.3 500 Hz 73.6 65.9 74.8 1000 Hz 69.9 65.0 72.5 2000 Hz 64.7 59.5 68.8 4000 Hz 66.5 55.2 65.6 8000 Hz 62.2 48.7 61.8 A -Weighted 77.0 71.3 78.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.39a Page 15 of 29 Project: -Untitledl8 Prepared By: Performance Summary For 02 10/23/2013 04:30PM Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 87.2 Lw B 57.8 66.1 67.7 71.6 72.5 70.0 66.6 60.7 77.7 LwA C 51.6 49.8 43.9 42.4 40.1 36.4 33.2 29.4 54.8 Lp D 25.4 33.7 35.3 39.2 40.1 37.6 34.2 28.3 45.3 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 20 18 16 04 02 CO CO 03 06 09 12 15 18 Airiiow(CFM-thousands) RPM=1442BHP=1.64 MaximumRPM=1466 MaximumBHP=2.90 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC -System Curve RP -Rated Point FanCurve \ 1 \ Ne153CRPM `\ ,'°awn" \ \ • ` \ \/ \ N \\ \ - \ \ 3.00B1P \\ ><.. 70C7PM \ \ / �, \\,� / N. N. 075813 `-, r1.00B1P •,203131-P; ,,1.5081-P NN \ \ _ SD3iPM - �� 1150131•P -I- \� \ 21 24 27 Packaged Rooftop Builder 1.39a Page 16 of 29 Project:-Untitled18 Prepared By: 03 10/23/2013 04:30PM 03 Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39a Page 17 of 29 Project:—Untitled18 Prepared By: Unit Report For 03 10/23/2013 04:30PM Unit Parameters Unit Moder 48TCDA07A2A6-0A0A0 Unit Size* 07 (6 Tons) Volts -Phase -Hertz. 460-3-60 Heating Type. Gas Duct Cfg. Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size* 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 16 x 2 Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length' 6' 2.375" Unit Width. 3' 8" Unit Height. 3' 5.375" *** Total Operating Weight. 662 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA07A2A6-0A0A0 Rooftop Unit 1 Packaged Rooftop Builder 1.39a Page 18 of 29 Project:—Untitled18 Prepared By: Certified Drawing for 03 10/23/2013 04:30PM NOTES: 1, 1X51!31 105 RIX i1L 110511111130511(33 2. S CENTER OF GRAv11! 3. 00, D11131/05 0f AIR FLOW UNIT 4810.04 1341111 ve 4310.405 13 1/0 10411 14 1/0 ❑111 4.TC.AD6 33 3/5 13411 1.um1/8 4310.401 41 3/3 110311 /4 v9 13111 FILTER ACCESS PANEL _ • I131-LE531 ' CON, CC[43 CO/DENSER COIL USE SIZES 1141.1 INDOOR COIL 1/1. 01/0 ACCESS PANEL 30 In 16131 11641 1/4- 144 O 1 4 4 0 1 1 1 E UES: BACK 1-011/91 TIP Cute 1 DTH 1E I/ 23111! 1 33 Ile 1.481 UNITED 4 /134513133 MUM.. CARRIER INRI R 4150 a4faiFug • EC04(31ZER141/000 01010.x 4.5/6 11111 LECT31CAl DISCONNECT LUCAl1ON *man FACT0R1 INSTAL CONVENIENCE 041100 11.1/6 14341 6.1/8 11493 3.3/4 115 463/4 111011 LEFT Vis 1 1 I 14511 1 114114;1/31 a v4 Iblll [1631 1!161 I SEE 1x94 THE_ 045E C41RT 14361 --- 15-5/3 16561 REIURM RIR 0 F AIT. — CONDENSATE DRAIN OPENING IN 346EPAN 11.3/4 14511 SUPPLI G- 1r �I511 11/940. 12111 RETURN AIR 34 �I I6 61-110 16131 11411 SUM! —63 Iblll 11001 440 TOP 164/8 � 1.51 14111 usl 161111 +• 14101 41114111 FAC1aI1 I Nft AllEO DISCONNECT _ CONTROL 001 PANEL _ o - C . • INDOOR 300'"ACCESS ACCESS _HANDLE CONDUIT SIZE USE SIZES 1141.1 x1NUE 1/1. 01/0 131• /00.21 30 In 16131 11641 11/1381 FRONT CONNECTION SIZES A 1 ll5• 1151 DIA FIELD POWER SUPPLY HOLE 1. 1301 DIA Pale SUPPI! 3x«5001 1 314. 1513 DIA GAUGE ACCESS PLUG lir 1661 DIA 3IC1D 0(31301 1119136 ROLE 3/4'14 MPT CONDENSATE DRAIN 111'14 APT GAS CONNECTION 1 1/6 ' 1441 DIA AMER SUPPLY 30013.051 1353-1HE-04 E CHAR INCCR0SE 15P5R001431 ES NE 003401 USE THREADED DIRE 1E01 NOTE CONDUIT SIZE USE SIZES 1141.1 1/1. ACC. 131• /00.21 4 1/4- 144 1/8. 166.11 1 4 3(4. 1001.0031 POKER 1 1le• 168.43 Z•• 10031 lll• FIT GAS 1 3115. 130.01 FOR • 1335-TUE-3ASEPAN• 1401331 413101. 3/111566 10R 05/! I.Y. 4 3 ARE PROVIDED • SELECT EITHER 1/4. 01 lip FOR P0111. DEPENDING ON WIRE 511E •• 01011 PROVIDES 314` FP1 INRU CURD FLANGE 1 FITTING. 8ARa1TRIC 11415E SKIT 1042 11-24-08 09-2908 48TC 04-01 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.39a Page 19 of 29 Project:-Untitledl 8 Prepared By: Certified Drawing for 03 10/23/2013 04:30PM 9011 S30. 9E10111 UNIT CORNER 11E1011 141 CORNER 9)16X1 111 CORNE5 95(5X1 ICI CORNEA 9)16X8 101 C.G. NF IGNt 185. O. LBS. H. LDS. 113. L05. NG. L85. 86. 8 1 I 4810-404 48) 211 111 50 125 51 131 58 111 53 35 11011 23 15841 11 3(8 (4111 4010405 551 244 154 56 139 8) 143 66 121 59 31 11911 23 15641 11 14521 4813-408 541 258 131 59 141 67 154 10 151 62 39 19911 23 15841 11 1/4 14301 4810-401 652 216 150 68 169 11 116 80 151 11 31 19911 23 15041 20 118 15111 CORNER A TOP FRONT ti lam' : 000 0 081150 1.0. 55[ 0101 i2CNN0(00135 Nn1[16[, n ei30 I1[ [185 4[0 11 1 i[ 01181(8 14441 [3055[1118 4 rilli[104485(81. a u 1x8 en 1 CORNER 8 CORNER C 2 Of 2 11-24-08 SVIKIKS 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.39a Page 20 of 29 Project:—Untitledl8 Prepared By: Performance Summary For 03 10/23/2013 04:30PM Part N um ber:48TC DA07A2A6-0A0A0 ARI EER. IEER• 11.00 11.2 Base Unit Dimensions Unit Length. 74.4 in Unit Width. 44.0 in Unit Height 41.4 in Operating Weight Base Unit Weight 652 Ib ..................... Medium Static Option 10 Ib Total Operating Weight 662 Ib Unit Unit Voltage -Phase -Hertz. 460-3-60 Air Discharge. Vertical Fan Drive Type Belt Actual Airflow. 2400 CFM Site Altitude 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB' 80.0 F Evaporator Entering Air WB' 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB' 57.6 F Evaporator Leaving Air WB. 57.1 F Evaporator Leaving Air Enthalpy 24.47 BTU/Ib Gross Cooling Capacity. 75.21 MBH Gross Sensible Capacity 58.11 MBH Compressor Power Input 5.11 kW Coil Bypass Factor 0.084 ............... Heating Performance Heating Airflow 2400 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 92.8 F Gas Input Capacity 72.0 MBH Gas Heating Capacity 59.00 MBH Temperature Rise. 22.8 F Supply Fan External Static Pressure. 0.75 in wg Options / Accessories Static Pressure Economizer 0.17 in wg Total External Static. 0.92 in wg Fan RPM:.. 1507 Fan Power 2.13 BHP NOTE. Selected IFM RPM Range: 1173 -1518 Electrical Data (Before July 30, 2012) Minimum Voltage:.... 414 Maximum Voltage' 506 Compressor #1 RLA. 9.7 Compressor #1 LRA. 62 Outdoor Fan Motor Qty 1 Outdoor Fan FLA (ea)' 0.8 Indoor Fan Motor Type MED Packaged Rooftop Builder 1.39a Page 21 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 03 10/23/2013 04:30PM Indoor Fan Motor FLA. 3.4 Combustion Fan Motor FLA (ea). 0.25 Power Supply MCA. 17 Power Supply MOCP (Fuse or HACK). 25 Min. Unit Disconnect FLA' .16 Min. Unit Disconnect LRA' 92 Electrical Convenience Outlet None Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA. Power Supply MCA. Power Supply MOCP. Disconnect Size FLA. 17 Disconnect Size LRA• .100 4.2 18 25 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 90.4 88.9 88.8 125 Hz 86.0 83.1 81.8 250 Hz 80.7 71.3 76.9 500 Hz 76.1 67.3 74.4 1000 Hz 72.4 66.5 73.3 2000 Hz 67.0 61.2 69.8 4000 Hz 68.8 57.1 66.3 8000 Hz 64.9 50.8 62.7 A -Weighted 79.2 72.6 78.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.39a Page 22 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 03 10/23/2013 04:30PM Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 90.1 Lw B 62.6 65.7 68.3 71.2 73.3 71.0 67.3 61.6 78.2 LwA C 56.4 49.4 44.5 42.0 40.9 37.4 33.9 30.3 57.7 Lp D 30.2 33.3 35.9 38.8 40.9 38.6 34.9 29.2 45.8 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 20 18 16 3 04 02 CO � 03 C6 09 12 15 18 21 Airflaw(CFM-thousands) RPM=1507 BHP=2.13 MaximumRPM=1585 MaximumBHP=3.70 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-SystemCurve RP-RatedPoint FanCurve 24 27 3fl 33 Packaged Rooftop Builder 1.39a Page 23 of 29 303RPM ` \ \\ 1500FiPM v� `\. 1 . 1 -.- , <1 9370A \ 210Cf3�Fu1 - _'is \ \ \`-- V1100RPM \\ 900RPIN , \ \ `\ \� \ \ ` \ \ art y \\ \ \ 70 1111 \ N \/ y ; f f \ •. \ \ \ 370E \ . '7-. \3.008 i•i: / 'N -0001 \ 0.758FP\-' 1.50BHP \ ., .• \'\ \\ \ \ 24 27 3fl 33 Packaged Rooftop Builder 1.39a Page 23 of 29 Project:-Untitledl8 Prepared By: 02A 10/23/2013 04:30PM 02A Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.39a Page 24 of 29 Project:-Untitledl8 Prepared By: Unit Report For 02A 10/23/2013 04:30PM Unit Parameters Unit Model. 48ES-A360606 Unit Size. 36 (3 Tons) Dimensions (ft. in.) & Weight (1b.)*** Unit Length. 4' 0.1875" Unit Width. 2' 8.625" Volts -Phase -Hertz. 460-3-60 Unit Height 3' 10" Heating Type. Gas "' Weights and Dimensions are approximate Weight does not include roof Duct Cfg. Vertical Supply / Vertical Return curbs, unit packaging, field installed accessories or factory 60,000 Btuh installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate Standard Unit product data catalog. Total Operating Weight 326 Ib Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48ES-A360606 Rooftop Unit 1 Accessories CPECOMZR007A00 Economizer 1 CPCRKHTR009A00 460V Crankcase Heater 1 Packaged Rooftop Builder 1.39a Page 25 of 29 Project:-Untitiedl8 Prepared By: Certified Drawing for 02A 10/23/2013 04:30PM 11 1116 1198.51 15-15/16 1104 •1 OUTDOOR COIL e 7/81 122.01 DEEP L 32 5/8 182e. 1 12-1]116 oau LEFT SIDE VIEW 3-1/16 187.31 125 4] M 9-15116 1252 11 RETURN 21 9116 - 9�t 5116 1511 11 1252 11 SUPPLY ,JUI11111/lllraST• n11�1 UMI/ 0 rzcHxola¢s srsrzss.404 CARRIER 11821 UNIT CNAAECTRICAILI<S UNIT WT. UNIT HEIGHT 11/MM CEN1ER 0E GRAVITY IM/NM 0 0G A Y 48E61-/NIA241040/060110 208/2301-60 301 131,8 40-1/ 1019 22-13/16 519.4 15-5/16 388.9 15411/16 398.5 448151,814301040/060113/510 208/230.1, 208/130-3-60 309 140 0 (('I/O 1010 2213/16 519 4 15-5/16 388 9 1513/16 401 6 40ES/-/016361060/090113/510 208/230-1, 208/230-3-60 319 111.6 16-1/8 1112 22-13/16 519.4 15-5/16 388.9 16-5/8 422.3 1BE51./N1A361060/090160 460-3-60 333 150.9 46.1/8 1172 2213/16 519.4 15-5/16 388.9 16-5/8 422.3 UNITS VOLTAGE CORNER WEIGHT /0104 '1' .5. 48E51 -/M IA241040/060130 2081230 45.6 20.1 60.8 24.6 41.4 106.3 48.3 48/ S1-/0 M01040/060113/ 301040/060113/ 5/0 19101 'IR 143610601090113/ 530 18[51/x IA16 060/090160 TOP VIEW PDOOR COIL liwiuiuui11 4-1 1111231 r/8 1 11:i3. e1 CG T Mir 1 .51 MEI o o: COM SSOA-, ANEL 8 6 11221311 01 PANa •10909 FRONT VIEW i.01421 PAN[/ 200100 208/230 460 46.3 11.8 41.0 21.0 21.1 61.8 63 B 63.8 28,0 28 9 28.9 92.6 95 6 104.E 12.1 43 4 41.5 6011 41. 14011 0411 IIEVINI 100 411 ',TO 4 INSTALLED 00110X5 /00/71 3020361X9 'I/OI. 128 61 014. 8 0 POWER ENTRY [22.21 DIA. NOL CONTROL [X TR 108.1 116.6 0 1146/01 4125.(141141".'''• 21/163116- 152.41 11.81 1 un6- 11ii 21 RIGHT ME VIEW 49.1 50 6 52.9 GEOID. 1]EVINKI3 TO C0635RHE 0003 TOP Or UNIT 0001 SID[ OF UxIT. .. .,. .. 310[ 001011 iE OU[i3 FLUE PANEL 1Q MUM 6FMD4ES. 1 1355.61 0 l0 01 16 1911 11 NCI! 02 001 BETWEEN UNITS. POWER ENTRY SIDE 2 2 1066.51 UNI1 AND UNGROUNDED SURFACES, POWER ENTRY SIDE 36/914.01 UNIT AND BLOCK OR CONCRETE WALLS MOTHER GROUNDED SURFACES, POWER DORY SIDE .... ... .... 42 11066 81 RIMED [9FMAP42 PM OPERATION NO 6FA6 t INCHES 1661 Elgi10 (010 ACCESS 510[ 36 1914.01 /1204 [NI AY SIO[ 12 11086.8] [1(201 104 NEC REOUIR[MENTSI UNIT 101 48 11219.21 SIDE OPPOSITE DUCTS... . . .. . ]6 [911 O] ._. 12 01.614 "19'0 0IS140200,11 4NI1 IS 8142[0 L200 1x68 12 [301.05 /AOM 0411 SYS/EO.TNE0 5151[6 P0020013024 0070E CO6PRO615ED. 151/8 1101.21 6-9/16 1166.11 l-I/16- IB7.31 DI61051200 IN 11 ARE 11 VN 111111111111111111111 •1/0 - 21-518 1250.81 1549.11 REARVIEW 9-118 mo.BI DATE 01/24/09 SUPEADEDIS S ENGLE 109E ELECTRIC COCLINC WITH CAS Hp;EAM (SMI 48E3500214 RED 3.0 Packaged Rooftop Builder 1.39a Page 26 of 29 Project: -Untitledl8 Prepared By: Performance Summary For 02A 10/23/2013 04:30PM Part Number:48ES-A360606 ARI SEER. Base Unit Dimensions Unit Length. Unit Width. Unit Height Total Operating Weight 13.00 48.2 in 32.6 in 46.0 in 326 Ib Unit Unit Voltage -Phase -Hertz 460-3-60 Air Discharge Vertical Fan Drive Type ..............Direct Actual Airflow- 1318 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB. ..60.9 F Evaporator Leaving Air WB. 58.8 F Evaporator Leaving Air Enthalpy 25.57 BTU/lb Net Cooling Capacity. 34.79 MBH Net Sensible Capacity. 27.18 MBH Total Unit Power Input 3.17 kW Coil Bypass Factor 0.048 Heating Performance Heating Airflow- 1318 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 103.7 F Gas Input Capacity. 60.0 MBH Gas Heating Capacity. 48.00 MBH Temperature Rise. 33.7 F Supply Fan External Static Pressure. 0.40 in wg Options / Accessories Static Pressure Economiser 0.24 in wg Wet Coil. 0.10 in wg Total External Static. 0.73 in wg Fan RPM' 1000 Fan Power 0.66 BHP Fan Motor Size, hp. 3/4 NOTE. Med-High Motor Speed, Vert Electrical Data Minimum Voltage- 414 Maximum Voltage- 506 Compressor RLA• 5.8 Compressor LRA. 38 Outdoor Fan FLA (ea)' 0.5 Indoor Fan Motor FLA' 3 Power Supply MCA. 107 Power Supply MOCP (Fuse or HACR). 15 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Packaged Rooftop Builder 1.39a Page 27 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 02A 10/23/2013 04:30PM Acoustics Sound Rating. 75.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 64.0 250 Hz NA NA 63.5 500 Hz NA NA 68.0 1000 Hz NA NA 70.5 2000 Hz NA NA 64.5 4000 Hz NA NA 61.0 8000 Hz NA NA 61.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver. 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 64.0 63.5 68.0 70.5 64.5 61.0 61.0 74.4 Lw B - 26.2 47.9 54.9 64.8 70.5 65.7 62.0 59.9 73.2 LwA C 0.0 31.6 31.1 35.6 38.1 32.1 28.6 28.6 42.0 Lp D - 26.2 15.5 22.5 32.4 38.1 33.3 29.6 27.5 40.8 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed Packaged Rooftop Builder 1.39a Page 28 of 29 Project:-Untitledl8 Prepared By: Performance Summary For 02A 10/23/2013 04:30PM that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39a Page 29 of 29 / qd\-sui,44 -010 City of Tukwila Department of Community Development November 22, 2013 CHRIS WALKER 899 MAIN ST AUBURN WA, 98001 RE: Correction Letter # 1 MECHANICAL Permit Application Number M13-198 OTIS ELEVATOR - 3315 S 116 ST Dear CHRIS WALKER, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. • PLAN SUBMITTALS: Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted. (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide the minimum fresh air settings for each unit per the calculations required in section 403 of the International Mechanical Code. 2. Units supplying more than 2000 cfm supply air are required to have duct smoke detectors to shut the unit down upon detection of smoke. Please show a duct detector on the return side of such units. When more than one unit serves the same area and the cfm for all units serving that area exceeds 2000 cfm, a duct detector is required for those units. 3. Please provide a floor plan to show the zone coverage of each unit. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-433-7165. Sincerely, tr, M.),LAR ki A146024 Jenniker l�larsha`�1 ermi Te File M13-198 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-198 DATE: 12/04/13 PROJECT NAME: OTIS ELEVATOR SITE ADDRESS: 3315 S 116 ST Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS! AJC, 1P -4P-(3 Building Division in Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/05/13 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/02/14 Approved ❑ Approved with ConditionsIN/ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center -Use Only" CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PERMIT COORD COPYS PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-198 DATE: 10/30/13 PROJECT NAME: OTIS ELEVATOR SITE ADDRESS: 3315 S 116 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: pry r1.0S•13 uil"ding Division Public Works Awl AWG ■ Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete T1 Incomplete DUE DATE: 10/31/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please RouteT. REVIEWER'S INITIALS: DATE: Structural Review Required n No further Review Required n APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 11/28/13 Not Approved (attach comments) DATE: Permit Center Use Only 1 i CORRECTION LETTER MAILED: 11'n 2 " 1� Departments issued corrections: Bldg Fire 0 Ping ❑ PW 0 Staff Initials:.. ,4t ' ID REVISION City of Tukwila SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / - J Plan Check/Permit Number: M1 3- 19 8 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Otis Elevator Project Address: //3315 S 116 Street Contact Person: �/(/►� ( 4) O(, l 1S el' Summary of Revision: RECEIVED CITY OF TUKWILA DEC 0 4 2013 PERMIT CENTER Phone Number: /5. -/31q -`/,941s- 1, 5 -/3q -`/,941s" 1, �,��sc,_ �-.�. C41-CrAlcAd loch s doAL p&r •11(0;‘ 4o3 *low = `7 % (7iiceel: 3. r7D 13b,e : q / 11-01L: 1 /a L f<rU w*iI he. p,d€4 a 6, 14.P ,C/c,o rf /)ioorF d 4. 4/1 5 1;-t5% torts Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Cee ter by: Entered in Permits Plus on 1` O? I C:\Users\jennifer-m\Desktop\Revision Submittal Form.doc Revised: May 2011 IECS INC 0 Washington State Department of Labor & Industries • Page 1 of 3 IECS INC Owner or tradesperson HUMPHREY, GEORGE Principals HUMPHREY, GEORGE Doing business as IECS INC WA UBI No. 601 639 846 PO Box 19252 SEATTLE, WA98109-1252 206-939-9495 KING, County Business type Corporation Governing persons GEORGEHUMPHREY License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. IECS***044QL Effective — expiration 11/13/1996 —11 /20/2014 Bond No bonds during the previous 6 year period. Insurance Nationwide Mutual Ins Co Policy no. ACPACTO7515636456 Received by L&I 07/26/2013 Savings (in lieu of bond) Received by L&I 11/20/2001 Savings account ID Active. Meets current requirements. $1,000,000.00 Effective date 08/01/2013 Expiration date 08/01/2014 $6,000.00 Effective date 11/20/2001 httns•//secure.lni.wa.gov/verifv/Detail.asnx?UBI=601639846&LIC=IECS* * *044QL&SA... 12/12/2013