Loading...
HomeMy WebLinkAboutPermit PG13-0149 - DOT - OPERATIONS BUILDING - GAS METERS / GAS LINEDOT OPERATIONS BUILDING 12100 EAST MARGINAL WY S PG13-0149 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 7340600421 12100 E MARGINAL WAY S Project Name: DOT - OPERATIONS BUILDING Permit Number: PG13-0149 Issue Date: 11/14/2013 Permit Expires On: 5/13/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KING COUNTY -TRANSIT 500 4TH AVE , SEATTLE, WA, 98004 PAUL YOUNG 7717 DETROIT AV SW , SEATTLE, WA, 98106 MACDONALD/MILLER FAC SOL INC PO BOX 47983 , SEATTLE, WA, 98106 MACDOFS980RU Phone: (206) 768-4230 Phone: (206) 768-4180 Expiration Date: 1/3/2015 DESCRIPTION OF WORK: INSTALL (2) GAS METERS: (1) ON THE MAIN GAS LINE AND (1) ON THE GAS LINES TO THE AHU'S Valuation of Work: $8,250.00 Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Fees Collected: $121.88 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: Date: 2012 2012 2012 u -i3 • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: _ Date: / / f { / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING CITY OF TUKWIli Community DevelopmWDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TtikwilaWA.gov Plumbing/Glermit No. -V613- 1461 Project No. Date Application Accepted: Date Application Expires: 1 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 7 3 `i 0%OU 9 2 Site Address: t oZ too e 1.0‘i S 9s 1 bite Number: Floor: Tenant Name: T(oT'- R se MOT opeve4.0,1s cS(cQ New Tenant: ❑ Yes PROPERTY OWNER , Name: Address: 121 ex, E YYla✓cltnc..1 wi 5 City:.-.A.x.t.J ; vA Sfate: W Fk Zip:gat (.,* CONTACT PERSON - person receiving all project communication Company Name: Address: .-/ ,, , -1 tje+vo;i- Prue Name: pc\ yoKn, Phone: Zo (D 768 .4.4,1:78 Fax: Zolo 74,42-Linci Contr Reg No.: Exp Date: RL D of s �o e N ► Z731 12613 _77 Address: .-1-I 1 1 (e-hro i 4- IA-ve- S") City: ew,ifl.e State: W p Zip: l (0.12 Phone: 'LOb "1 (1:2 -'c(2 30 Fax:.Z -7 G5- 4I 2-3 Email: PLUMBING CONTRACTOR INFORMATION Company Name: Address: .-/ ,, , -1 tje+vo;i- Prue City: a4 Le_ State: W r) Zip40 Oh Phone: Zo (D 768 .4.4,1:78 Fax: Zolo 74,42-Linci Contr Reg No.: Exp Date: RL D of s �o e N ► Z731 12613 _77 Tukwila Business License No.: C5u S - b 1 op S(oS Valuation of Project (contractor's bid price): $ ea/9- So Scope of Work (please provide detailed information): I -' 5 u- C2-) s (I) ' Z iM Pki n C�1 AS ( t) bvi 11'4g. 60--5 Vines -(r Al -U5 Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/t piping outlets being installed and the quant. low: Fixture Type Qty Bathtub or combination . bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL t h OWNER 0 AUT Signature. Print Name: ZED AGENT: Mailing Address: ' ) \ A),S-3 Date: \ l 01 2 013 Day Telephone: 20(0 6.3— 1" 7 S H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Se,,Iftpc w (A- cr SSI o City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 - Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.2,ov RECEIPT Parcel No.: 7340600421 Permit Number: PG13-149 Address: 12100 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 11/01/2013 Applicant: DOT Issue Date: Receipt No.: R13-03038 Initials: WER User ID: 1655 Payment Amount: $121.88 Payment Date: 11/01/2013 01:28 PM Balance: $0.00 Payee: MACDONAL MILLER FACILITY SOLUTIONS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3770 121.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES 000.322.103.00.00 97.50 000.345.830 24.38 Total: $121.88 Printarl• 11_n1_9n1'� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 13-U t ciC/ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-245 Project: 1)(T C PPR. -ti Cj Type of Inspection: I' tCk—;,...1 Address: _ ‘2_1 0 U enSY 0A -4,,,Q4( Date Called: .. . Special Instructions: Date Wanted: • - 17. _ i (a.m., p:m. Requester: - L_/ i Phone G C�b - 7.Z6 I Approved per applicable codes. • Corrections required prior to approval.. COMMENTS: pc f n^, - L` / Date: • - \Z—L!. ri REINSPECTION FEE REQUI ED. Prior td next inspection. fee must be id a't 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SllhiE 11111111G. 111C. Sage Integral Prime Insertion Style, 24 VDC Power NG/s11-(y 95-0100A Specifications Wetted Parts: 316L SS Wetted Parts, C267 Hastelloy Options Available Outputs: 4-20mA (Flow), 24VDC Pulse (Total) Process Temperature: Standard -40° to 200°F, Optional to 300° F and 450° F Digital Communication: Modbus RS485/RTU Pressure Rating: 500psig, 1000psig Optional User Supplied Power: 24VDC (18-28VDC) Accuracy: +/- y/% of Full Scale +/- 1% of Reading Power Consumption: 2.4 Watts Maximum Repeatability: 0.2% Approvals: CSA C22.2, UL1604, Class I Div 2 Groups B,C,D Enclosure: Nema 4, Powder Coated Aluminum Electronics Temp Rating: -40° to 150° F (-40° to 66° C) Probe Lengths SIP - Code U Code U 1/2" Diameter 3/4" Diameter 05-06 6" (152 mm) 07-06 6" (152mm) 05-12 12" (305 mm) 07-12 12" (305mm) 05-15 15" (381 mm) 07-15 15" (381mm) 05-18 18" (457 mm) 07-18 18" (457mm) 05-24 24" (610 mm) 07-24 24" (610mm) 05-30 30" (762 mm) 07-30 30" (762mm) 05-36 36" (914 mm) 07-36 36" (914mm) 07-48 48" (121.9mm) 4 - 5/8" Model Number ( Example: SIP -!05j- 06J-DC24- (CO2)) - -DC24- J L J 1/2- NPT Entry for Wiring 2 PLC 4 - 3/8" (110mm) REVIEWED FOR CODE COMPLIANCE APPROVED NOV 08 2013 City of Tukwila Gas I BUILDING DIVISION Code Code AIR AIR CL2 CHLORINE N2 NITROGEN CO CARBON MONOXIDE NG NATURAL GAS HE HELIUM CH4 METHANE H2 HYDROGEN PROPANE PROPANE DIG GAS DIGESTER GAS BUTANE BUTANE BIOGAS BIOGAS NH3 AMMONIA LFG LANDFILL GAS CO2 CARBON DIOXIDE FLARE GAS FLARE GAS AR ARGON FLUEGAS FLUEGAS 02 OXYGEN MIX MIXTURE 03 OZONE !1 Basic Wiring Diagram 1 amp, 24 VOC Powe, Sop,I . 24V DC 24V DC A B C • • • L 0 0 ( 2 0 0 0 3 0 0 0 4 0(0 0 5 066 6000 Ground 81.1 A)-) 24 WC Pulse ammo) 4.20mO Output 1.1 Common Ground) -1 PSNS PTO IInternale Powered «neon Sage Metering, Inc. /8 Harris Court/ Building D-1/ Monterey, CA 93940/ t: 866-677-7243/f: 831-655-4965/www.sagemetering.com SIIGE • 1111I p 1, 1R 1. Sage Remote Prime Insertion Style, 24 VDC Power 95-0103A Specifications Wetted Parts: 316L SS Wetted Parts, C267 Hastelloy Options Available Process Temperature: Standard -40° to 200°F, Optional to 300° F and 450° F Pressure Rating: 500psig, 1000psig Optional Accuracy: +/- %2 % of Full Scale +/- 1% of Reading Repeatability: 0.2% Enclosure: Nema 4, Powder Coated Aluminum Electronics Temp Rating: -40° to 150° F (-40° to 66° C) SRP Probe Lengths Code © Code 1/2" Diameter 3/4" Diameter 05-06 6" (152 mm) 07-06 6" (152mm) 05-12 12" (305 mm) 07-12 12" (305mm) 05-15 15" (381 mm) 07-15 15" (381mm) 05-18 18" (457 mm) 07-18 18" (457mm) 05-24 24" (610 mm) 07-24 24" (610mm) 05-30 30" (762 mm) 07-30 30" (762mm) 05-36 36" (914 mm) 07-36 36" (914mm) 07-48 48" (1219mm) Outputs: Digital Communication: User Supplied Power: Power Consumption: Approvals: Model Number (Example: SRP- OS] - [061-DC24- jC621) -DC24- 4-20mA (Flow), 24VDC Pulse (Total) Modbus R5485/RTU 24VDC (18-28VDC) 2.4 Watts Maximum CSA C22.2, UL1604, Class I Div 2 Groups B,C,D Gas Code Code AIR AIR CL2 CHLORINE N2 NITROGEN CO CARBON MONOXIDE NG NATURAL GAS HE HELIUM CH4 METHANE H2 HYDROGEN PROPANE PROPANE DIG GAS DIGESTER GAS BUTANE BUTANE BIOGAS BIOGAS NH3 AMMONIA LFG LANDFILL GAS CO2 CARBON DIOXIDE FLARE GAS FLARE GAS AR ARGON FLUEGAS FLUEGAS 02 OXYGEN MIX MIXTURE 03 OZONE , I Amp, 24 VDC Powe, Supply 1 ` Basic Wiring Diagram A B C • • • 1 o o 6 2 006 3 0 0 0 4 Ground l•1 Id 24 VDC Ruh. Output (01 420,40 Ootp I (0) RS4/5 RN IInternally Powered anpda Sage Metering, Inc. /8 Harris Court/ Building D-1/ Monterey, CA 93940/ t: 866-677-7243/f: 831-655-4965/www.sagemetering.com r PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-149 DATE: 11-01-13 PROJECT NAME: DOT - OPERATIONS BUILDING SITE ADDRESS: 12100 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: C: 141.6 B'uTfdin Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-05-13 Complete Comments: Incomplete u Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S IF\ Structural Review Required n No further Review Required ITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 12-03-13 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Pri r Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD/MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite/Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 1/3/2015 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI*988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2014 Active LINFOAR980QG LINFORD AIR @ REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVCOI*031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760PMACDONALDMILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDONALD MILLER MACDOM'248J9 CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 TURLEY, DOUGLAS Chief Executive Officer 02/13/2008 01/04/2011 TURLEY, DOUGLAS Chief Operating Officer 02/13/2008 01/04/2011 SIGMUND, FREDRIC President 12/31/2002 01/04/2011 HACK, RICHARD Secretary 02/13/2008 01/04/2011 KOPET, TYLER Treasurer 12/31/2002 01/04/2011 LOVELY, STEVE C Vice President 12/31/2002 01/04/2011 Bond Information Page 1 of 2 Bond 1 Bond Company Name LIBERTY MUTUAL INS CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Assignment of Savings Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 11/14/2013 7045 TF0_01.dwg =7 J:\733\7045 KC Metro — South Bose NG Submeters — JD\00\2 — Engineering\DWG\Shts\733 '1NG GENERAL NGT PIPING MATERIAL SCHEDULE: PIPING SIZE MATERIAL JOINT NATURAL GAS 1/7 - 2" 2-1/2" -10" SCH 40 BLK STL ASTM A53 A OR B SCH 40 BLK STL ASTM A53 A OR B THREADED, FLANGED, SOCKET WELDED BUTT WELDED FLANGED, 12"+ STD WT BLK STL ASTM A53 A OR B BUTT WELDED FLANGED - PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES, WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. - AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 IBC, IMC, AND UPC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2012 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 5. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 6. PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 7. PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 8. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. APN# 734060-0421 LEGAL DESCRIPTION: RIVERSIDE INTERURBAN TRS TRACTS 17 THRU 20 LY SWLY OF SWLY MGN OF PSH NO 1 TGW POR OF LOTS 21 & 22 LY NLY OF A LN 789.91 FT N AS MEAS ON ELY MGN OF CO RD FR SW COR OF LOT 31 LESS ST HWY TGW POR OF GOV LOT 15 IN SW 1/4 OF SEC 10-23-04 LY ELY OF E MGN OF MARGINAL WAY TGW POR OF LOT 1 OF RIVERTON ADD LY ELY OF ELY MGN OF MARGINAL WAY TGW STRIP OF LAND LY NLY OF SAID LOT 1 OF RIVERTON ADD & SLY OF LOT 19 OF RIVERSIDE INTERURBAN TRACTS & LY BTW POR GOV LOT 15 AS DAF ABOVE & A 40 FT VAC ST ADJ RIVERSIDE STONE QUARRY TGW SD 40 FT STRIP ADJ RIVERSIDE STONE QUARRY. OPERATION BUILDING: INSTALL (2) NEW GAS METERS: (1) ON MAIN GAS LINE, (1) ON GAS LINE TO AHUS. WGAS MT NAME TITLE TF0.01 SCHEDULES & SITE MAP TF2.01 OPERATION BUILDING FLOOR 1 - FITTING TF3.01 DETAILS - FITTING NAME TITLE SYMBOL 03.4 DESCRIPTION GATE VALVE GLOBE VALVE BALL VALVE - FULL PORTED ING_:LEGE ABBREVIATION GV GLV BV SYMBOL DESCRIPTION A SOLENOID VALVE GAS COCK TAT CIRCUIT SETTER VALVE ABBREVIATION_ SV GC CS SILENT CHECK VALVE BUTTERFLY VALVE BUTTERFLY VALVE W/ MEMORY STOP FLEXIBLE CONNECTION CV BFV BFVM Q© HORIZONTAL EXPANSION TANK G I>= VERTICAL EXPANSION TANK 1:1, I= AIR SEPARATOR 1-6-11=1 AIR PURGER HET VET AIR SEP AP ® REDUCED PRESSURE BACKFLOW PREVENTER RPBP END SUCTION CENTRIFUGAL PUMP ES PUMP UNION STRAINER PI PRESSURE RELIEF VALVE e" PRESSURE REDUCING VALVE PRESSURE / TEMPERATURE TAP BULB WELL MANUAL AIR VENT AUTOMATIC AIR VENT UNION STRN RV --------- PRV P&T BW MAV AV q�+ VERTICAL IN-LINE CENTRIFUGAL PUMP SUCTION DIFFUSER TEMERATURE GAUGE — A — COMPRESSED AIR VI PUMP SUC DIFF TG C CONDENSATE PIPING — CHWS — CHILLED WATER SUPPLY PIPING — CHWR — CHILLED WATER RETURN PIPING — CWS— CONDENSER WATER SUPPPLY PIPING PRESSURE GAUGE PG THERMOMETER THERM BALL VALVE W/ 3/4" HOSE ADAPTOR BV W/ HA CONCENTRIC REDUCER CR — CWR— CONDENSER WATER RETURN PIPING — G — GAS PIPING — L — REFRIGERANT LIQUID LINE — S — REFRIGERANT SUCTION LINE ECCENTRIC REDUCER ER — HWS — HEATING WATER SUPPLY PIPING L1 TWO-WAY CONTROL VAVLE THREE-WAY CONTROL VALVE 2WAY 3WAY — HWR — HEATING WATER RETURN PIPING REVISIONS No changes shall be to the scope of work without prapproval of Tukwila Build f NOTE: Revisions will 0. new plan submitt-1 and may include additic: l elan review fees. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing 0 Gas Piping City of Tukwila BUILDING DIVISION \\ 1 I 1 • ♦♦ ♦♦ • • • ♦♦ ♦ N OPERATION BUILDING • ♦♦ ( • • - • SOUTH BASE MAINTENANCE BUILDINGS 1 • • • • • • • • •• • •• • •• • C COMPONENT SUPPLY CENTER tt 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Lfp It 1 1 1 01 1 O 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2013 City of u Ila BUILDING ISION FIL.OPY rmlt No. 1,h Plan re . w approval is subject to errors and omission Approval of construction documents does not authoriz the violat +n of any adopted code or ordinance. Recei of approve Field Copy and Is BY City Of 1Ukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 0 1 2013 PERMIT CENTER VG13 �y 9 a)" as O 0 U oti coo N. a)o � N al U) LL (/) O N O Co) (D o ) N 0 co. 0 tid E U t]) 0 fi3 E 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 �1 0 0 ENGINEER: P YOUNG E75 cr.) -% • ETEMEMIA -773 zta • ELTIMIMMA co 0 0 LLI 0 0 0 CZ 0 0 EXPIRES: 07-06-14 REVISIONS: LAST REVISED: 10-30-13 CHECKED BY: DATE PLOTTED: B GEZON 10-30-13 CAD: ISSUE DATE: D LAMBERT 10-30-13 DRAWING NUMBER: SHEET NUMBER: TF0.01 NEW SRP GAS METER. WIRING BY OTHERS. EXISTING SHUT-OFF VALVE. EXISTING VENT TO OUTSIDE. EXISTING WALL SLEEVE. NEW SIP GAS METER. WIRING BY OTHERS. EXTERIOR WALL EXISTING GAS COCK GRADE TO AIR HANDLING UNITS. 3" GAS GAS PRESSURE REDUCING VALVE. TO STEAM CLEANER ROOM 2 1/2" GAS 1 1/2" GAS GAS FLOOR TO BOILER TO DOMESTIC HOT WATER HEATER SOUTH OPERATING BASE GAS PIPING DIAGRAM NO SCALE 2� TF3.01 NEW SRP GAS METER. - WIRING BY OTHERS. EXISTING SHUT-OFF VALVE. EXISTING VENT TO OUTSIDE. EXISTING WALL SLEEVE. NEW SIP GAS METER. WIRING BY OTHERS. EXTERIOR WALL EXISTING GAS COCK GRADE 2" GAS 3" GAS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 8 2013 City of Tukwila BUILDING DIVISION TO AIR HANDLING UNITS. 3" GAS GAS PRESSURE REDUCING VALVE. TO STEAM CLEANER ROOM AND RADIANT HEATING SYSTEM 2 1/2" GAS TO HOT WATER GENERATOR AND IMMERSION CLEANERS 3" GAS TO BOILER FLOOR COMPONENT SUPPLY CENTER GAS PIPING DIAGRAM NO SCALE ?GI3 i'vi RECEIVED CITY OF TUKWILA NOV 0 1 2013 PERMIT CENTER W Z 0 0 o r` rnCO m a) 0 E N A• LL • . d Q - ti E 8 < Q r 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Irl 0 I 0 I I I I I I l< Z 0 o0 �Z c� Z W Z u- Q QUO � Q Z W� Wcf)a <coo Q. D W QO ♦♦^^O VJ co co 5 J_ F - ENGINEER: P YOUNG CHECKED BY: B GEZON CAD: D LAMBERT DRAWING NUMBER: EXPIRES: 07-06-14 0 REVISIONS: w 0 REVISIONS: LAST REVISED: 10-30-13 DATE PLOTTED: 10-30-13 ISSUE DATE: 10-30-13 0-2055-7337045-00 SHEET NUMBER: TF3.01