Loading...
HomeMy WebLinkAboutPermit PG13-0168 - AIRFIELD BUSINESS PARK - ALTERATIONAIRFIELD BUSINESS PARK 9124 E MARGINAL WAY S PG13-0168 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 5422600150 Permit Number: PG13-0168 9124 E MARGINAL WAY S BLDG B Project Name: AIRFIELD BUSINESS PARK Issue Date: 12/30/2013 Permit Expires On: 6/28/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WOOD MEADOWS LLC PO BOX 654 , KIRKLAND, WA, 98083 STEVE CARNEY 8706 S 222 ST, KENT, WA, 98031 STATE MECHANICAL COMPANY 8706 S 222 ST, KENT, WA, 98031 STATEMC141C7 Expiration Date: 9/1/2015 Phone: (206) 575-7527 Phone: (206) 575-7527 1/I DESCRIPTION OF WORK: PLUMB AND INSTALL (1) SINK, (2) LAVS, (1) WATER HEATER, AND (2) WATER CLOSETS Valuation of Work: $6,890.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $244.38 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Date: � 01 • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name:1300W J /Vp yF c Date: /39/fg This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 2: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 3: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 4: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 5: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 6: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 7: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 9: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 10: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 11: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 12: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 15: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. • • 16: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUK41 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Plumbing/Gas Permit No. (7(71;-otO Project No. II Date Application Accepted: l� �� \l3 Date Application Expires: 6Ut t11 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 5422600150 Site Address: 9124 E Marginal Way So Suite Number: Floor: Tenant Name: Airfield Business Park PROPERTY OWNER Name: Steve Carney Address: 8706 S 222nd St Name: Phone: (206) 575-7527 Fax: (206) 575-7529 Email: stevec@statemech.net Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Steve Carney Address: 8706 S 222nd St City: Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Email: stevec@statemech.net New Tenant: El Yes ❑ ..No PLUMBING CONTRACTOR INFORMATION Company Name: State Mechanical Co Address: 8706 S 222nd St City: Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Contr Reg No.: STATEMC141C7 Exp Date: 09/01/2015 Tukwila Business License No.: BUS -0101359 Valuation of Project (contractor's bid price): $ 6,890 Scope of Work (please provide detailed information): To Plumb and insta11 Seater closets,-I-m'in t; 2 lavatories I) Itvii, ( 1) 61 Building Use (per Int'I Building Code): Occupancy (per Int'! Building Code): Utility Purveyor: Water: Sewer H.\Annliratinnc\Fnrrnc_ Annliratinnc /ln 1 in,A 011 Annliratinnc\Plnmhinn Permit Annliratinn Rrvicn,1 R-9-11 rine Indicate type of plumbing fixtures and/o s piping outlets being installed and the quanti e1ow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap 2 Sinks 1 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory 2 Urinal 2 Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 2 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNEjt OR AUTHORIZED AGENT: Signature: /`d�.'*"� Date: 12/17/2013 Print Name: Steve Carney Day Telephone: (206) 575-7527 Mailing Address: 8706 S 222nd St Kent Wa 98031 1-MAnnliratinnc\rnrmFAnnliratinne fln 1 ineV011 Annliratinnc\PI”mhim, Permit Annlientinn Reviced R_0_11 finer City State Zip Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $488.76 PG13-0167 Address: 9112 E MARGINAL WAY S BLDG B Apn: 5422600150 $244.38 PLUMBING $244.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $163.00 PLAN CHECK FEE R000.322.103.00.00 $48.88 PG13-0168 Address: 9124 E MARGINAL WAY S BLDG B Apn: 5422600150 $244.38 PLUMBING $244.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $163.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R417 R000.322.103.00.00 $48.88 $488.76 Date Paid: Tuesday, December 17, 2013 Paid By: STATE MECHANICAL CO. Pay Method: CHECK 4203 Printed: Tuesday, December 17, 2013 10:39 AM 1 of 1 CRWSYSTEMS -F3 INSPECTION RECORD Retain a copy with permit °6(3 ` v/4 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 n Permit Inspection Request Line (206) 431-2451 Projegct:p�pf A:f t-,' CA/ 0 8)s4c . f Ty Inspection: y s I ;i' (u (� f NA . A6 Addr�e (�� F; � 9E MA/6.A/41....--- Date Called: Special Instructions: A -f✓\ Date Wanted: — 7I/ — /4 p.m. Requester: Phone No: - Approved per applicable codes. Corrections required prior to approval. COMMENTS: PIMA, A,t 4) A4 1 G Date: 2 4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter.Blvd., Suite 100. Callao schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC-TION NO. PERMIT NO. /3-6/(Yr CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 - Projects .j ^ j f r.1' /'( l/S,-ft '5 Type of Inspection: 2 A c Gt - , Address: 9 ! 2 if *. YN t4 2 fc1 0vi9 / Date Called: Special Instructions: Date Wanted: am. Requester: .Ji =Jf- ?)(AA--- )(AArPhone PhoneNo: 6/2 -/ Cr--. 6/6r Approved per applicable codes. El Corrections required prior to approval. COMMENTS: mss- d dLJ o i F /1740e (ern ter' Allo Pa :'J9-0 )(-/1792rs / Date: 3-31-/y REIN PECTION FEE REQ !RED. Prior to next inspection, fee must be p•'fiat 6300 Southcenter olvd., Suite 100. Call to schedule reinspection. PC) (3.(9rO INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: A-,trgt(An 4-'s, PA -4r Type of Inspection: rotJ..->wJ Address: L,rSpat 12i - A.kA16!&.i AL.-- Date Called: ecial Instructions: Special Date Wanted3: _ 2-4— �} 4 ..v ra.m. p Requester: t 7✓ Phone No: ZS -33 0 - Oto Approved per applicable codes. D Corrections required prior to approval. COMMENTS: (4(J Ung w o rizi. Lijk -re Ins ector: Date _24 r 4 C REINSPECTION F7E REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO.. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF:TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431=2451 Project:l� !�F; f -\i e . {C' �k J & . � Ty a of Inspection: ( 1--l$-0 &..1L,) Address: _ q 1 2-4 :1,11Mt ,, Date Called: d 9 Special Instruction • ,J r `- - Lit: I Date Wa ted: J `o--f-.j L .m.` p. . Requester: Phone No: DApproved per applicable codes. Corrections required priorto approval. COMMENTS: 1 Ell Date: _21 )/z y W s IN PECTION FEE REQUI ED. Prior to n xt inspection, fee must be t 6300 Southcenter Blv ., Suite 100. •all to schedule reinspection. 2"V 1-1/2° V 1-1/2" V WC 3" VTR 2°V WC TIE INTO EXISTING 4" WASTE *CLEAN OUTS PER CODE 3/4" HWS 3/4" CW TIE INTO EXISTING WATER 1 3/4" CW 3/4" CW 3/4" CW I 3/4" HW 1/2" HW 1/2" CW SINK LAV WC WC * HOT WATER TANK TO HAVE EQ STRAP, EXPANSION TANK a DRAIN ._,, P&11Yelt�4 FILE COPY Permit No. DESIGN BY STATE MECHANICAL 8706 S 222ND ST KENT, WA 98031 DECEMBER 16, 2013 AIRFIELD BUSINESS CENTER COLD WATER a WASTE AND VENT RISER NOT TO SCALE P I - _- ----, ...a .I, M:,,..:..,., REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED DEC 19 2013 PUBLIC WOW:: RECEIVED CITY OF TUKWILA DEC 1 7 2013 PERMIT CENTER Ale PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-0168 DATE: 12/17/13 PROJECT NAME: AIRFIELD BUSINESS PARK SITE ADDRESS: 9124 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A Wc- 1e -i3 Building Division ss `�3 Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/19/13 Complete i4rJ Incomplete Not Applicable Comments: Permit Center Use Ontly. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S/INITIALS: DATE: Structural Review Required ❑ No further Review Required n APPROVALS OR CORRECTIONS: DUE DATE: 01/16/14 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only; CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: Joanna Spencer From: Sent: To: Subject: Todd Reedy Monday, December 23, 2013 3:17 PM Joanna Spencer RE: Airfield Business Park PG13-0167 and PG13-0168 Hi Joanna, Airfield Business Park is current on backflow preventer installation and testing. There is a single 4" domestic connection with an RPBA that is current and a 6" fire DCDA that is current. Hope you have a great holiday, Todd From: Joanna Spencer Sent: Monday, December 23, 2013 2:40 PM To: Todd Reedy Cc: Han Kirkland; David McPherson; Michael Cusick; Joanna Spencer Subject: Airfield Business Park PG13-0167 and PG13-0168 I have two addresses: a) 9112 EMWS and b) 9124 EMWS. Are their backflows current? Thanks, Joanna 1 PERMANENT FILE COPY P 0168 STATE MECHANICAL COMPAN: AWashington State Department of �,� Labor & Industries • Page 1 of 2 STATE MECHANICAL COMPANY Owner or tradesperson PLATZ, GERRICK D Principals PLATZ, GERRICK D JOHN LYNCH RALPH DEWITT Doing business as STATE MECHANICAL COMPANY WA UBI No. 600 611 697 8706 S 222nd St KENT, WA98031 206-575-7527 KING, County Business type Corporation Governing persons GERRIKPLATZ License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. STATEMC141 C7 Effective — expiration 02/27/1986 — 09/01/2015 Bond TRAVELERS CAS & SURETY CO Bond account no. 200686359 $6,000.00 Received by L&I Effective date 08/14/2001 07/27/2001 Insurance James River Ins Co $1,000,000.00 Policy no. 000590200 Received by L&I Effective date 08/22/2013 08/23/2013 Expiration date 08/23/2014 Savings No savings accounts during the previous 6 year period. httns://secure.lni.wa. aov/verify/Detail.aspx?UBI=600611697&amp;LIC=STATEMC 141 C7&amp;S... 12/30/2013 6.0 FLOOR FL4N: EMO NORTH SCALE: 1/8•• , 11_0" 303'-8" 250'-0" 23'-5" 22'-8" 23'-5" 24'-2" 23'-5" 23'-5" NEUJ OFFICE 884 SF E E RECEP. FUTURE OFFICE E PANSION OFFICE RR OPEN OFFICE 12'x12' ROUGH IN FOR FUTURE COFFEE BAR WAREHOUSE RR SEPARATE PERMIT R.U1RED FOR: 7.517 SQ.FT. 0 OGAS UNIT HEAT (SUSP. FROM CEIL.) WAREHOUSE 02 OPEN TO \ STRUCTUREI ABOVE � Steahanical electrical 0 Plumbing Cilres Piping c ` 1 of Tukwila .. • DIVISION WAREHOUSE 01 OPEN TO \ STRUCTURE \ ABOVE / 0oQ BLDG. SPRINK: RISER REVISIONS No changes shall be made to the scope of work without prior approval of Building Division. 177. "t^}riill require a new plan submittal additional �._ Wan rev;ew f':' ..,. FX.W COPY Permit No r&13—DI(v8 Plan review approval is subjel to errors and omissions. Lit, -;;-;-.7...1.!a! of construction documents does not authorize etc ::o`w`siorF of any adopted code or ordinance. Receipt n 4pproved Field Cop and 011: 4 13 ;4.1 4 rd. 6 16'x12' REC'V DR By Date: , 30 City Of TiJkwifa BUILDING DIVISION 7' 22'-8" 22'-8" 24'-2" 22'-8" 303'-8" FLOOR FLAN : NEW NORTH SCALE: 1/8" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED DEC 192013 TUKVvi PUBLIC WORKS RECEIVED CITY OF TUKWILA DEC 17 2013 PERMIT CENTER P1713- Res 303'-8" 250'-0" 23'-5" 23'-5" 23'-5" / 22'-8" 24'-2" 23'-5" / / (' GAS UNIT HEAT 0 (SusP. FROM CEIL.) ° oQ BLDG. SPRINK. RISER --,( WAREHOUSE 01 OPEN TO STRUCTURE ABOVE 3( -4 7.517 SQ.PT. o GAS UNIT HEAT (susp. FROM CEIL.) o r WAREHOUSE . 1. SUB. PANEL 1 1 r -' 02 REC'V / OPEN TO \ STRUCTURE \ ABOVE / 16'x12' DR. 22'-8" 24'-2" it 22,-8" FLOOR FL4N: EMO NORTH SCALE: 1/8•• , 11_0" 303'-8" 250'-0" 23'-5" 22'-8" 23'-5" 24'-2" 23'-5" 23'-5" NEUJ OFFICE 884 SF E E RECEP. FUTURE OFFICE E PANSION OFFICE RR OPEN OFFICE 12'x12' ROUGH IN FOR FUTURE COFFEE BAR WAREHOUSE RR SEPARATE PERMIT R.U1RED FOR: 7.517 SQ.FT. 0 OGAS UNIT HEAT (SUSP. FROM CEIL.) WAREHOUSE 02 OPEN TO \ STRUCTUREI ABOVE � Steahanical electrical 0 Plumbing Cilres Piping c ` 1 of Tukwila .. • DIVISION WAREHOUSE 01 OPEN TO \ STRUCTURE \ ABOVE / 0oQ BLDG. SPRINK: RISER REVISIONS No changes shall be made to the scope of work without prior approval of Building Division. 177. "t^}riill require a new plan submittal additional �._ Wan rev;ew f':' ..,. FX.W COPY Permit No r&13—DI(v8 Plan review approval is subjel to errors and omissions. Lit, -;;-;-.7...1.!a! of construction documents does not authorize etc ::o`w`siorF of any adopted code or ordinance. Receipt n 4pproved Field Cop and 011: 4 13 ;4.1 4 rd. 6 16'x12' REC'V DR By Date: , 30 City Of TiJkwifa BUILDING DIVISION 7' 22'-8" 22'-8" 24'-2" 22'-8" 303'-8" FLOOR FLAN : NEW NORTH SCALE: 1/8" = 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED DEC 192013 TUKVvi PUBLIC WORKS RECEIVED CITY OF TUKWILA DEC 17 2013 PERMIT CENTER P1713- Res