Loading...
HomeMy WebLinkAboutPermit PG13-0174 - WOOD RESIDENCE - REPLACE WATER HEATERWOOD RESIDENCE 4904 S 107 ST PG13-0174 • City of Tukwila � Qsti Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: WATER HEATER PERMIT 5476800219 Permit Number: PG13-0174 4904 S 107 ST Project Name: WOOD RESIDENCE Issue Date: 12/31/2013 Permit Expires On: 6/29/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: WOOD DAVID H+CHARLOTTE E RE 4904 S 107TH ST , TUKWILA, WA, 98178 NANCY EVANS 1425 BLAINE AVE NE , RENTON, WA, 98056 WASHINGTON CORROSION SRVC INC 1425 BLAINE AVE NE , RENTON, WA, 98056 Phone: (425) 228-1393 Phone: (425) 228-1392 License No: WASHICS055KC Expiration Date: 5/4/2014 Lender: Name: Address: 111 DESCRIPTION OF WORK: REPLACING ELECTRIC WATER HEATER Valuation of Work: $900.00 Water District: TUKWILA Sewer District: NONE Fees Collected: $46.50 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: W3/ ) r • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: ` Z- 3 (' } 3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL • 8005 ROUGH -IN PLUMBING Receipt Number DESCRIPTIONS I ACCOUNT QUANTITY I PAID PG 13-0174 Address: 4904 5 107 ST Apn: 5476800219 $46.50 PLUMBING PERMIT ISSUANCE BASE FEE WATER HEATER FIXTURE FEE TOTAL FEES PAID BY RECEIPT: R531 R000.322.100.00.00 R000.322.103.00.00 $46.50 $32.50 $14.00 $46.50 Date Paid: Tuesday, December 31, 2013 Paid By: ANGELA H LUDWIG Pay Method: CREDIT CARD 063561 Printed: Tuesday, December 31, 2013 11:56 AM 1 of 1 is i CITY OF TUKAtA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi IaW A. gov Plumbing/Gas Permit No. ?G/3-0/7(77 Project No. Date Application Accepted: /6Y-3/ Date Application Expires: o 4130/1q (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4904 s 107th st Tenant Name: C 14 a r I € 14e PROPERTY OWNER Name: Nancy Evans Address: 1425 Blaine ave ne Name: charlette Wood Phone: (425) 228-1393 Fax: City: Renton State: wa Address: 4904 s 107th st Phone: (425) 228-1393 Fax: City: tukwila State: wa Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Nancy Evans Address: 1425 Blaine ave ne Address: 1425 Blaine ave ne Phone: (425) 228-1393 Fax: City: Renton State: wa Zip: 98056 Phone: (425) 228-1393 Fax: Email: 06evans@comcast.net King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No PLUMBING CONTRACTOR INFORMATION Company Name: Washington Corrosion Service Address: 1425 Blaine ave ne City: renton State: wa Zip: 98056 Phone: (425) 228-1393 Fax: Contr Reg No.:washics055kc Exp Date: 05/14/2013 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 900 Scope of Work (please provide detailed information): Replacing Electric Water Heater Building Use (per Int'l Building Code). Occupancy (per Intl Building Code): Utility Purveyor: Water. Sewer. H:WpplicationsWorms-Applications On Line\201 I ApplicaziansU'lumbmg Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R R AUTHORIZED AGENT: Signature: 1 1 V Print Name: Angela Ludwig Mailing Address: 1425 Blaine ave ne H:\Applications\Forms-Applications On Line \2011 Apphcations\Plumbmg Permit Application Revised 8-9-11.dacx Revised: August 2011 bh Date: Day Telephone: (425) 228-1393 Renton wa 98056 City State Zip Page 2 of 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 PG (3-c)17q Y1 Project:Typerpf c� o�k. Inspection: I ?( lA — I is.,.. — I•- t NA l...-- AdL14 0L S .t O Date Called: Special.lnstructr ns: % 01\C ,/ Date Wanted: r a.m. cn, Requester: kk_vlct-kt Ph20-7z, —Sorz 3 El -Approved per applicable codes. Corrections required prior to approval: COMMENTS: oL� j 11. Date: PEGTION FEE REQUIED. Prior for next inspection, fee must be. t_ at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. WASHINGTON CORROSION SR. INC 40 Washington State Department of Labor & Industries 1 Page 1 of 2 WASHINGTON CORROSION SRVC INC Owner or tradesperson EVANS, NANCY J Principals EVANS, NANCY J ANGELA EVANS (LUDWIG) JOHN EVANS WA UBI No. 601 577 751 1425 BLAINE AVE NE RENTON, WA98056-2774 425-228-1393 KING, County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties APPLIANCES/EQUIPMENT License no. WASHICS055KC Effective — expiration 05/03/1995 — 05/04/2014 Bond CBIC Bond account no. SD6182 Received by L&I 05/02/2002 Insurance Western World Ins Co Policy no. NPP1347707 Received by L&I 05/09/2013 $6,000.00 Effective date 05/02/2002 $500,000.00 Effective date 05/04/2013 Expiration date 05/04/2014 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings during the previous 6 year period. Tax debts No tax debts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601577751 &amp;LIC=WASHICS055KC&amp;S... 12/31/2013