HomeMy WebLinkAboutPermit PG13-033 - BOEING #9-101 - FREEZER ADDITION ALTERATIONBOEING #9-101 FREEZER ADDITION 9725 EAST MARGINAL wys PG1 3-033 City ok ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9-101 - FREEZER ADDITION Permit Number: PG13-033 Issue Date: 06/06/2013 Permit Expires On: 12/03/2013 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124 Contact Person: Name: CONNIE HARDIN Address: 4600 S 134 PL , TUKWILA WA 98168 Email: CONNIEH@HOLADAYPARKS.COM Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA 98188 Contractor License No: HOLADPI379NO Phone: 206-250-4530 Phone: 206 248-9700 Expiration Date: 09/03/2013 DESCRIPTION OF WORK: INSTALL (2) FLOOR DRAINS, (1) HUB DRAIN AND TRAP PRIMERS, (1) HOSE BIBB Value of Plumbing/Gas Piping: $20,000.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $154.88 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: Date: 10 ' 4 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio .or the pe ormance • f worly-I•am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of thiss pe 't 1111. � ► moi' Signature:_ Print Name: v -e Date: V(0.-( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. n.:..a..d. nc nc nn4o PERMIT CONDITIONS Permit No. PG 13-033 1: ***PLUMBING .AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG13-033 Printed: 06-06-2013 1 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd , Suite 100 Tukwila. WA 98188 http://www.TukwilaWA.gov q'- bl rtcze-40 °`. C:13 3.3 Plums remit No. - 0 Project No. (For .o;fce use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 4325,4-„ G-_ t ai cb Tenant Named y ����"""�' PROPERTY OWNER - Name: Addres 4 City' 7 to %I"- 20-0b Stater 1 Zip!ri„ 124 ;.CONTACT PERSON - person`receivu g all project communication Name:`OAIIAt'Gc4LA Address:q S vgLikk ei Citye StatU a Zietc(16 k `'1.ar?A e. w Phon) � z 0H.5 Fax: 7 4, Z'i 7 b Email: lWKl{ p:V ' k p IQ r rk .( •vA i/tl King Co Assessor's Tax No.: frX)3tW Ot" Suite Number: Floor: New Tenant: ❑ Yes .P,L JMBING`CONTRACTORTNFFORRMATION Company Name: Wicks ISS Address: s ' i L/� City: State ,'1�J45(2167? Phone,Z c( Fax: z^o6�•Z g- j 7.07) Contr Reg N.t-:©Pt 3 _rXJ Date: et/`3 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ zt, 000 Scope of Work (please provide detailed information): Building Use (per Intl Building Code). Occupancy (per Int'I Building Code): Utility Purveyor: Water H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: Augus12011 bh f- T/L4r- /-,'/07E7 s (/) 1," /3/d Sewer: Page 1 of 2 • Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain -- [/ Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type . Qty Bidet Drinking fountain or water cooler (per head) -- [/ Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial -- [/ Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Floor -- [/ Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0',�1 ;.n . H t RIZED Signature: Print Name:aives‘ 1`e_ iNitxrA t �. Mailing Address: "ttOO S `S1.I— i -e H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: ,� L .— ( 3 Day Telephone: f, Z SZsgr30 City State ctaelk Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 0003400018 Permit Number: PG13-033 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 03/06/2013 Applicant: BOEING #9-101 - FREEZER ADDITION Issue Date: Receipt No.: R13-01834 Payment Amount: $123.90 Initials: WER Payment Date: 06/06/2013 03:06 PM User ID: 1655 Balance: $0.00 Payee: CONNIE HARDIN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05016G ACCOUNT ITEM LIST: Description 123.90 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 123.90 Total: $123.90 Printad• nR-OR-7013 r � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: PG 13-033 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 03/06/2013 Applicant: BOEING #9-101 - FREEZER Issue Date: Receipt No.: R13-00970 Payment Amount: $30.98 Initials: WER Payment Date: 03/06/2013 01:17 PM User ID: 1655 Balance: $123.90 Payee: CONNIE HARDIN TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01134G ACCOUNT ITEM LIST: Description 30.98 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 30.98 Total: $30.98 Prinfad• n'i_na_9n13 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IZ (206) 431-367 Permit Inspection Request Line (206) 431-2451 P6/3-03.3 Proj15 l� TYPE .. Inspection: -_ u Address: I)/ 5 E M> N erAix Date C Ie t -- 4 kL . �`�-�- k'�- F, Special Instructions: Date Wanted-, "-T 43 P AIL. r m. '7 Requester: P neiNc'8_573 R/ zt____ Approved per applicable codes. Corrections required prior to approval. COMMENTS: o �`�-�- k'�- F, perar-,t i r\s AP --S kdue r. so P -e e. T \O!re c-- [ldor . [ rid <Y____. 4%tr4, Dated n REINSPECTION FEE REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - Ins ector: INSPECTIO t NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit 3.- 033 Project: f 7��- n �' - ( i Type of Inspectio�n:Q !') U �)\.c .i.6 r ( l Z_S r- ,t,{ !U G Ade s: r : 1 ` v�ate Called: Special Instructions: e6 -.L �C — IV1� . h f k' �% Date Wanted: i`a rpt. �• L� r(3 p.m. Requester: Phone No: (, .7 o 7 _ 6 Approved per applicable codes. Corrections required prior to approval. COMMENTS: i� S i+ L AV' l Inspe4tor: Date: J' l 3 REINSPECTION FEE REQU RED. Prior o° next inspection. fee must be paid at 6300 Southcenter Blvd,. Suite 1 0. Call to schedule reinspection. April 16, 2013 Connie Hardin Holaday Parks Inc 4600 S 134 P1 Tukwila, WA 98168 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #2 Plumbing/Gas Piping Permit Application Number PG13-033 Boeing #9-101 — 9725 East Marginal Wy S Dear Ms. Hardin, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Dave Larson at 206-431-3678 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431-3670. Sincerely, shall ician File: PGI3-033 kjAdiS W:IPermit CenterlCorrection Letters12013IPG13-033 Correction Letter #2.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo #2 Date: April 15, 2013 Project Name: Boeing #9 -101 -Freezer Addition Permit # PG13-033 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please add pages M1 and MIA for clarification of abbreviations. 2. Please add page C302 for continuation or points of connection of new plumbing systems. 3. Is the scissor lift sump a oil/water or sand interceptor? Per a phone conversation with Derek (Holaday Parks) it is not intended to be part of the scope of this permit. Please add a note stating that a separate permit will be applied for by others. Also note that it will need to connect to the sanitary sewer and this point of connection should be shown on the civil plan sheets. It may also need to be readily accessible and may not be in this location. The application of the scissor lift sump by others will need to be reviewed concurrently with this permit. 4. On page 1M148 a floor drain is labeled as FD -B and appears to be the same floor drain that is labeled FD- A on UGM148. Please make labeling consistent. This drain should have a trap primer. Please correct plans as necessary. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. March 21, 2013 Connie Hardin Holaday Parks Inc 4600 S 134 P1 Tukwila, WA 98168 City• of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Plumbing/Gas Piping Permit Application Number PG13-033 Boeing #9-101 — 9725 East Marginal Wy S Dear Ms. Hardin, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Dave Larson at 206-431-3678 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431-3670. Sincerely, Bill Rambo Permit Technician encl File: PG13-033 W:IPermit CenterlCorrection Letters12013IPG13-033 Correction Letter #!.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 \moi Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: March 20, 2013 Project Name: Boeing #9-101 — Freezer Addition Permit # PG13-033 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide and isometric line drawing of the drain, waste and vent work proposed. Include required cleanouts, pipe sizes, connection points to existing system and vent piping to the roof. 2. The scope mentioned in the application is inconsistent with the plans. The plans include condensate drains and vacuum lines. Please remove these items as they should be included in a mechanical permit instead of a plumbing permit. As an option to removing these things you could cloud the intended scope to match the description of scope in the application. 3. On page 1M143, note #1 states connect 1 inch CW to existing domestic cold water pipe. CW is assumed to be chilled water and a closed system that would need to be isolated from the domestic water via a RPBA backflow device. Please provide an elevation view to show this connection with an approved backflow device, other valves and drains needed. Please provide the make and model number of the backflow device. If a backflow device is not appropriate for this connection, please explain why. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. Page 2 of 2 �y7J■ Yls. 1L� J •_ ` r t l G. �r11 p• CO PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-033 DATE: 05-23-13 PROJECT NAME: BOEING #9-101 - FREEZER ADDITION SITE ADDRESS: 9725 EAST MARGINAL WY S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 2 Revision # After Permit Issued DEPARTMENTS: ,� o if ®(ait'ding ivision Public Works n Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: [xi Incomplete DUE DATE: 05-28-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 06-25-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 06MT Me) C• PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-033 DATE: 04-08-13 PROJECT NAME: BOEING #9-101 - FREEZER ADDITION SITE ADDRESS: 9725 EAST MARGINAL WY S Original Plan Submittal _ Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # DEPARTMENTS: Building Division Public Works 1 Fire Prevention n Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 04-09-13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route X Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05-07-13 Approved Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg tk Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • • PES T GO y x PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-033 DATE: 03-06-13 PROJECT NAME: BOEING #9-101 - FREEZER ADDITION SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT it n ivl ion Fire Prevention Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03-07-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04-04-13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) 11-- Notation: "Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: �"` I Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVTSION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: s'—,- l Plan Check/Permit Number: PG 13 -03 3 ❑ Response to Incomplete Letter # • Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-101 — Freezer Addition Project Address: 9101 East Marginal Wy S Contact Person: 0,0 twe_, Summary of Revision: k:e_cc Phone Number: HtCEI'VED CITY vF !UKWIIA MAY 2 2 2013 PERMIT CENTER G0, G -OA,,& -L, i\Ax .�[� LL&MtL(�� kI<< IVhILI3) Sheet Number(s): 1 L (p JJ � k (ton "Cloud" or highlight alt areas 6f revision ihcludinn date of rev cion Received at the City of Tukwila Permit Center by: Entered in Permits Plus on C:\Users\jennifer-m\Desktop\Revision Submittal Form.doc Revised: May 2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 46'413 Plan Check/Permit Number: PG 13-033 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Boeing #9-101 — Freezer Addition Project Address: 9725 East Marginal Wy S Contact Persona wt. k4A Summary of Revision: tluur 1 4- *i Phone Number: 1.0 •ZS—D•143 D ON OF TUKWIL A APR 0 8 201 PERMIT CENTER Sheet Number(s): V feM‘kifc 1Mlu3t 1 m14(0), 1 Wl 041/1VIA Ie b 1" Vvt4 � W "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications\forms-applications on Iine\revision submittal Created: 8-13-2004 Revised: Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLADAY PARKS INC UBI No. 578004089 Phone 2062489700 Status Active Address 4600 S 134Th Pt License No. HOLADPI379NO Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State WA Expiration Date 9/3/2013 Zip 98168 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADI.00105 HOLADAY PARKS INC Electrical Contractor Hvac/Rfrg Ltd Energy Unused 9/25/2000 4/29/2015 Active HOLADPF376NO HOLADAY PARKS FABRCTRS INC Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR Chief Executive Officer 01/21/1983 Amount VAN DER VEEN, JULIE ELIZABETH Member 08/26/2011 A1CG96431203 CONNELL, DANIEL AARON Member 08/26/2011 GIRI, BUIT Member 08/26/2011 Old Republic Ins Co KIEL, RINALD HOWARD Member 08/26/2011 WHITMYRE, CHRISTIAN Member 08/26/2011 24 BECK, DAVID CLARENCE Vice President 01/21/1983 11/01/2012 OCONNOR, BONNY K Vice President 01/21/1983 10/28/2011 NAILON, JUNE ANNETTE Vice President 01/21/1983 VAN DER VEEN, ERIC M Vice President 11/04/2010 PIZZEY, GRACE KATHERINE Vice President 08/26/2011 NELSON, MICHAEL Secretary 01/01/1980 11/04/2010 PARKS, DAVID L Treasurer 01/01/1980 11/04/2010 TALBOT, PAUL Treasurer 01/01/1980 11/04/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 LIBERTY MUTUAL INS 23000452 CO 09/01/2002 Until Cancelled $12,000.00 08/23/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 Old Republic Ins Co A1CG96431203 11/01/2012 11/01/2013 $1,000,000.00 10/30/2012 25 Old Republic Ins Co A1CG96431102 11/01/2011 11/01/2012 $1,000,000.0010/28/2011 24 Old Republic Ins Co A1CG96431102 11/01/2011 11/01/2012 $1,000,000.00 10/28/2011 httns://fortress.wa. s?ov/lni/bbip/Print.aspx 06/06/2013 VICI \ TTY NAP SITE PROJECT FROM DOWNTOWN SEATTLE o0 0 99 DOT 157 EAST MARGINAL WAY CORPORATE PARK 99 FROM SEATTLE -TACOMA AIRPORT DEVELOPEV FROM KENT & AUBURN 900 ENTAL CE \TER NO SCALE BOEING WORKPLACE SERVICES BUILDING 09-101.1 DC FREEZER ADDITION BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA NAP 3UILDI\G ADDRESS: 9725 EAST VARGINAL WAY SOUTH TU <W I LA, WAS H I \GTO \ 09-06 Mechanical Electrical Plumbing Fa Gas Piping City of Tukwila BUILDING DIVISION 9-78 9-52 9-35 MFC 13-01 6 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review f .01_.. 1 PROJECT SITE 9-101 3UILDI\ G LOCATIO NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of to wila BUILDING DIVISION CODE SUMMARY TYPE OF APPLICATION: NEW ❑ ALTERATION ❑ ADDITION. TENANT IMPROVEMENT ❑ PROJECT DESCRIPTION: PROJECT CONSISTS OF AN APPROX 10,000 SF FREEZER BUILDING ADDITION TO THE EXISTING 9-101 FACTORY BUILDING . CODES: 2009 INTERNATIONAL BUILDING CODE (IBC), AS ADOPTED AND AMENDED BY THE CITY OF TUKWILA 2009 INTERNATIONAL FIRE CODE (IFC) 2009 INTERNATIONAL MECHANICAL CODE (IMC) 2008 NATIONAL ELECTRICAL CODE (NEC) 2009 UNIFORM PLUMBING CODE CONTRACTOR & STATE NUMBER: THE BOEING CO. BOEINC *294ML, EXPIRES 1/21/15 BOEING PROJECT ENGINEER: BOEING CONTACT: JOHN MURDOCH PHONE: 253-657-0868 FAX NUMBER: 253-657-0858 E-MAIL: john.s.murdoch@boeinq.com OCCUPANCY GROUP: GROUP F-1 (HIGH -BAY) & GROUP B (OFFICE), NO WORK PROJECT S1 -INDUSTRIAL THIS AREA CONSTRUCTION TYPE: TYPE II -B (NO CHANGE) ZONING: ALLOWABLE AREA INCREASE: NO CHANGE UNLIMITED OCCUPANT LOAD: (ALLOWABLE) BLDGS SF (TABLE 10-A) TUNNEL (F-1 OCC.) OCC, NO CHANGE 1ST FLOOR F-1 OCC.) OCC. NO CHANGE MEZZANINE (B OCC.) OCC. NO CHANGE 2ND FLOOR (B OCC.) OCC. NO CHANGE TOTAL ALLOWED: OCC. NO CHANGE PROJECT ADDITION OCC. 21 FLOOR AREA: (ACTUAL) BLDG GROSS 1,116, 306 TUNNEL 713,829 1ST FLOOR HIGH -BAY 713,829 MEZZANINE 55,689 2ND FLOOR OFFICE 31,280 FREEZER 10,125 PROJECT AREA SQ FT SQ FT SQ FT SQ FT SQ FT SQ FT BUILDING HEIGHT: (ACTUAL) 111'-0" (NO CHANGE) STORIES: 2 ACTUAL MEZZANINE ? El (YES) • (NO) SQ FT ARE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 ? • (YES) ❑ (NO) SEPARATION NONE REQUIRED (PER IBC TABLE 508.4) EXTERIOR WALL (NON-BEARING) HOUR RATING N/A EXTERIOR WALL (BEARING) HOUR RA11NG N/A INTERIOR WALL (NON-BEARING) HOUR RA11NG N/A INTERIOR WALL (BEARING) HOUR RATING N/A DEMOUNTABLE PARTITIONS HOUR RA11NG N/A STRUCTURAL FRAME HOUR RATING N/A FLOOR/CEIUNGS HOUR RA11NG N/A ROOF CONSTRUCTION HOUR RA11NG N/A SHAFT ENCLOSURES HOUR RATING N/A SEISMIC DESIGN CATEGORY FREEZER (SDC): "D" DESIGN LOADS FREEZER: (CHAPTER 16) ROOF FREEZER: UVE (SNOW) 20 PSF LIVE FLOOR: OFFICE N/A MECH/STOR 25 PSF STAIRS 40 PSF (PSF) 25 PSF MIN SNOW (PSF) (PSF) (PSF) CONCENTRATED: WIND FREEZER: EXPOSURE CATEGORY D BASIC WIND SPEED 85 MPH IMPORTANCE FACTOR 1.0 (FOR OCCUPANCY CATEGORY II) CODES AND PERMITS PROJECT TITLE: 9-101.1 DC FREEZER ADDITION QUANTITY SUBMITTED: ® 4 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT ❑ 4 SETS: TENANT IMPROVEMENT (NON—STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) CIVIL SUBMITTED PREVIOUSLY UNDER SEPARATE PERMIT SUBMITTED FOR PERMIT & REVIEW: BUILDING ❑ PLUMBING ❑ MECHANICAL ® STRUCTURAL JOB NUMBER: 16262 ❑ GRADING ❑ LANDSCAPE ❑ DEMOLITION ❑ ELECTRICAL ❑ FIRE PROTECTION SIE ❑ CANTILEVER RACKS ❑- * TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE -APPROACHES COMPLIANCE OPTION ❑ PRESCRIPTIVE ❑ LPA ❑ ANALYSIS II N/A SPECIAL INSPECTIONS REQUIRED: (PER IBC CH. 17) WELD • CONCRETE ® REBAR • ANCHOR BOLTS III STRUCTURAL BOLTING • STRUCTURAL OBSERVATION ❑ OTHER ❑ GRADING, EXCAVATION, FILLING ▪ DRILLED—IN & GROUTED ANCHORS SEE SHEET S1, S2K, S2L, S2M, S2N, S2P FOR MORE INFO. CALCULATIONS TYPE: ATTACHED (YES) (NO) CODE DESCRIPTION DESCRIPTION: FREEZER ADDITION IS DESIGNATED AS S-1 MODERATE HAZARD STORAGE FOR MATERIALS USED IN FABRICATION FOR VARIOUS AIRCRAFT ASSEMBLIES. (IBC SECTION 311.2); S-1 FREEZER IS ACCESSORY TO THE 9-101 F-1 FACTORY BUILDING, DIRECTLY CONNECTED. GENERAL CONSTRUCTION: FOUNDATION PILE SUPPORTED SLAB, SLAB IS OVER HIGH DENSITY INSULATION OVER SAND BED W/ GLYCOL HEATING SYSTEM. STRUCTURE IS STEEL SUPPORTING INSULATED METAL PANELS FOR FINISH WALLS AND METAL DECK ROOF W/ MEMBRANE ROOFING OVER RIGID INSULATION. OCCUPANCY GROUP: STORAGE GROUP PER IBC 311: S-1 OCCUPANCY, MODERATE HAZARD STORAGE, ACCESSORY TO F-1 FACTORY: ACCESSORY USE IS LESS THAT 10% OF F-1 BUILDING PER IBC 508.2.1; ACTUAL IS 0.9%; ALLOWABLE AREA AND HEIGHT: NOT AFFECTED BY S-1 FREEZER ADDITION PER IBC 508.2.1 CONSTRUCTION TYPE TYPE II -B, NON-COMBUSTIBLE (IBC TABLE 601) INTERIOR SEPARATIONS - PER IBC TABLE 508.4, THERE IS NO SEPARATION REQUIRED BETWEEN F-1 AND S-1. SEPARATION ON SITE MINIMUM SEPARATION (EXISTING): 60 FEET TO PROPERTY LINE ON EAST MARGINAL WAY SOUTH. SEIFILEI CORYBUILDINGS ON THE BOEING DC CAMPUS NOT AFFECTED. �22 `�% ACTUAL FLOOR AREAS: Perml�t No. FLOOR AREAS -EXISTING 9-101 - FIRST FLOOR, SECOND FLOOR AND MEZZANINES: TOTAL: 1,116,306 S.F. Pian review approval Is subject to errors and omissions. FLOOR AREA -FREEZER ADDITION - FIRST FLOOR (INCLUDING 955 S.F. FOR MECH jructlon documents does not authorize TOTAL:10,125 S.F. the violation of any adopted code or ordinance. Receipt TOTAL EXISTING AND NEW: 1,126,431 S.F. of approved t.Is : edges! ALLOWABLE FLOOR AREA: UNLIMITED AREA PER IBC 507.3 FOR F AND S OCCUPANCIESBY MAXIMUM BUILDING HEIGHT ALLOWED -ADDITION: 75 FT (IBC TABLE 503 AND SECTION -504.2){ Date. ( /(37/ ACTUAL HEIGHT OF ADDITION: 33 FEET MAXIMUM ROOF PLANE ELEVATION FOR SINGLE STORY FIRE PROTECTION: FULLY SPRINKLERED THROUGHOUT. SPRINKLER SYSTEM IN 9-101 DC FREEZER ADDITION: DOUBLE INTERLOCK, PRE -ACTION SYSTEM WITH HEAT DETECTION WIRES PER NFPA 13; IN -RACK SPRINKLERS PROVIDED. FOR FUTURE RACKS. OCCUPANT LOAD PER IBC TABLE 1004.1.1. FREEZER ADDITION: S -1 -MODERATE HAZARD STORAGE (WAREHOUSING): 10,125 S.F./500S.F. PER OCC. = 21 OCCUPANTS TOTAL EXITS REQUIRED PER IBC SECTION 1015.1: {. 1 EXIT CORRECTION MAY 2 3 2013 EXITS PROVIDED: L.TR#, Z )`I FREEZER: 3 PERMIT CENTER MAXIMUM DISTANCE TO EXIT: S-1 OCCUPANCY: 250 FT MAXIMUM W/ SPRINKLER SYSTEM THROUGHO (IBC TABLE 1016.1). ALL AREAS OF FREEZER ADDITION ARE WITHIN 250 FT OF AN EXIT. MAX COMMON PATH OF EGRESS TRAVEL REQUIRED: 100 FT PER 1014.3 EXCEPTION 2 ACTUAL COMMON PATH OF EGRESS TRAVEL IS LESS THAN 100 FT. MINIMUM TOILET FACILITIES. REQUIRED PER WA STATE AMENDMENTS TO IBC TABLE 2902.1: SPACE IS NOT A FULL-TIME STAFFED SPACE, ASSIGNED WORK FORCE IS FROM ADJACENT 9-101 BUILDING. THEREFORE, THERE IS NO CHANGE IN THE TOILET FACILITIES REQUIRED. FOAM PLASTIC PER IBC 2603.3: ALLOWED IN THICKNESS UP TO 10 INCHES WHERE THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1 FREEZER ADDITION COMPLIES FOR ROOF INSULATION AND INSULATED WALL PANELS City Of Thkwila BUILDING DON RECEIVED CITY OF TUKWILA THERMAL RESISTANCE WAREHOUSES: ROOF WALLS SLAB ON GRADE PERIMETER OVERHEAD DOORS REQUIREMENTS PER WA STATE ENERGY CODE (COMATE ZONE 1) & TABLE 13.3 FOR REFRIGERATED FREEZER REQUIRED: R-36 MIN; PROVIDED: R-55, MIN. REQUIRED: R-36 MIN; PROVIDED R-45 W/ THERMAL BREAK R-36 MIN; PROVIDED: CONTINUOUS R-36 UNDERSLAB INSULATION THROUGHOUT. (PRIMARY LARGE FREEZER DOORS): U -VALUE OF 0.60 U -VALUE PROVIDED 0.036 (R-28) ISSUED FOR CONSTRUCTION APRIL 12, 2013 NON -FREEZER REQUIRED: R-30 MIN; PROVIDED: R-30, MIN. REQUIRED: R-13 MIN PLUS R-7.5 MIN CONTINUOUS INSULATION; PROVIDED: R-20 PANEL W/ R-19 BATT. R-39 TOTAL REQUIRED: R-10 MIN; PROVIDED: R-10, EXCEPT VERTICAL R-10 INSULATION ONLY AT FOUNDATIONS OF NON -OCCUPIED MECHANICAL AND ELECTRICAL ROOMS (R-1.6) MIN ?G10 33 DLR Group Architecture Entineering Manning; Interiors SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DC FREEZER ADDITION J#16262 DLR GROUP VW 04.12.13 irAFEAVAW ® REGISTERED ARCHITECT ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DLR GROUP DATE 04.12.13 CHECKED VW 04.12.13 SUBTITLE TITLE SHEET CURRENT REVISION J#16262 SYMBOL DATE 04.12.13 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE PERMIT MASTER DC FREEZER ADDITION BUILDING 09-101.1 COL. Z/21-22.5 DEV. CENTER, WA SHEET GO JOB NO. J#16262 COMP NO. DWG NO. 09 -101 -GO MJANES: 4/8/2013 2:37:24 PM DRAWING INDEX DRAWING NUMBER REV DRAWING TITLE GENERAL 09-101—GO — TITLE SHEET 09-101—GOA — SHEET INDEX 09-101—G1 - SYMBOLS AND ABBREVIATIONS 09-101-1A03 L COMPOSITE FLOOR PLAN SURVEY 09—YD—C22A — SURVEY CIVIL 09—YD—C2A — CIVIL GENERAL NOTES 09—YD—C162 — TEMPORARY EROSION AND SEDIMENTATION CONTROL PLAN 09—YD-C232R — PAVEMENT PLAN (REMOVAL) 09—YD-C235R — PAVEMENT PLAN (REMOVAL) 09—YD—C302R — UTILITIES SITE PLAN (REMOVAL) 09—YD-C305R — UTILITIES SITE PLAN (REMOVAL) 09—YD—C402R — STORMWATER DRAINAGE PLAN (REMOVAL) 09—YD—C405R — STORMWATER DRAINAGE PLAN (REMOVAL) 09—YD—C92 — GRADING PLAN 09—YD—C95 — GRADING PLAN 09—YD—C232 — PAVEMENT PLAN 09—YD—C235 - PAVEMENT PLAN 09 -YD -C302 — UTILITIES SITE PLAN 09-YD—C305 - UTILITIES SITE PLAN 09—YD—C402 - STORMWATER DRAINAGE PLAN 09—YD—C405 — STORMWATER DRAINAGE PLAN 09—YD—0576 — SECTIONS AND DETAILS 09—YD—0577 09-101—A566 SECTIONS AND DETAILS DRAWING INDEX DRAWING INDEX DRAWING NUMBER DRAWING TITLE REV DRAWING TITLE - ARCHITECTURAL - REMOVAL 09-101-1 A43R — E REMOVAL FLOOR PLAN 09-101-1 A46R MECHANICAL EQUIPMENT SCHEDULE—EAST ANNEX D REMOVAL FLOOR PLAN MECHANICAL EQUIPMENT SCHEDULE—EAST ANNEX ARCHITECTURAL 09-101-1 A43 PARTIAL UNDERGROUND PLUMBING PLAN E FLOOR PLAN 09-101-1A46 09-101-1M143 D FLOOR PLAN 09-101-1A48 H — FLOOR PLAN — FREEZER 09-101-1A318 1ST FLOOR PLUMBING PLAN — REFLECTED CEILING PLAN — FREEZER 09-101—RFA207 09-101-1M298 — ROOF PLAN — FREEZER 09-101—A63 — — BUILDING ELEVATIONS — NORTH & SOUTH 09-101—A64 CONTROL DIAGRAMS A BUILDING ELEVATIONS - EAST & WEST 09-101—A65 09-101—M616 — BUILDING ELEVATIONS — ENLARGED 09-101—A215 — SECTIONS 09-101—A216 REFRIGERATION NOTES — SECTIONS 09-101—A361 PS-5830—M3b — SCHEDULES AND DETAILS 09-101—A455 — — ENLARGED PLANS 09-101—A564 UNDERGROUND GLYCOL PIPING — DETAILS 09-101—A565 PS -5830-M612 — NOT USED 09-101—A566 — — DETAILS 09-101—A567 ROOF PLAN — DETAILS 09-101—A568 480Y/277V POWER DISTRIBUTION FLOOR PLAN — DETAILS 480Y/277V POWER DISTRIBUTION FLOOR PLAN STRUCTURAL - GENERAL 09-101—S1 — ABBREVIATIONS/SYMBOLS/DRAWING LIST 09-101—S2K — GENERAL NOTES 09-101-S2L — GENERAL NOTES 09-101—S2M — GENERAL NOTES 09-101—S2N — LOAD MAPS 09-101—S2P — LOAD MAPS M STRUCTURAL - REMOVAL 09-101-1 S43R C — PARTIAL FOUNDATION PLAN — REMOVAL 09-101-1S46R 277V/480Y POWER PLAN — PARTIAL FOUNDATION PLAN — REMOVAL 09-101-1 S93R 09-101-1E448 — PARTIAL FIRST FLOOR PLAN - REMOVAL 09-101-1S96R A — PARTIAL FIRST FLOOR PLAN — REMOVAL — STRUCTURAL 09-101-1S48 — — PARTIAL FOUNDATION PLAN 09-101-1S98 PARTIAL ROOF 480Y/277V POWER PLAN — PARTIAL FIRST FLOOR PLAN 09-101—RFS198 09-101—E4S73 — PARTIAL ROOF FRAMING PLAN 09-101—S237 B — FRAMING ELEVATIONS 09-101—S238 FREEZER ONE—LINE DIAGRAM — FRAMING ELEVATIONS 09-101—S239 09-101-SK—E616 — BRACE ELEVATIONS 09-101—S240 — — BRACE ELEVATIONS 09-101—S296 — SECTIONS AND DETAILS 09-101—S297 — TYPICAL FOUNDATION DETAILS 09-101—S298 — SECTIONS AND DETAILS 09-101—S299 - SECTIONS AND DETAILS 09-101—S300 — SECTIONS AND DETAILS 09-101—S404 — TYPICAL STEEL COLUMN DETAILS AND SCHEDULE 09-101—S405 — TYPICAL STEEL BEAM CONNECTIONS 09-101—S406 — TYPICAL STEEL BEAM CONNECTIONS 09-101—S407 — TYPICAL STEEL DETAILS 09-101—S408 — TYPICAL STEEL JOIST DETAILS 09-101—S409 — TYPICAL BRACED FRAME DETAILS 09-101—S410 — TYPICAL BRACED FRAME DETAILS 09-101—S411 — TYPICAL BRACED FRAME DETAILS 09-101—S412 — TYPICAL COLD FORMED STEEL DETAILS 09-101—S413 — TYPICAL COLD FORMED STEEL DETAILS 09-101—S624 — SECTIONS AND DETAILS DRAWING INDEX DRAWING NUMBER REV DRAWING TITLE MECHANICAL 09-101—M1 - HVAC LEGEND 09-101-M1A — PIPING LEGEND 09-101-M1 E E MECHANICAL EQUIPMENT SCHEDULE—EAST ANNEX 09-101-M1 H M MECHANICAL EQUIPMENT SCHEDULE—EAST ANNEX 09-101—UGM148 — PARTIAL UNDERGROUND PLUMBING PLAN 09-101-1 M48 — 1ST FLOOR HVAC PLAN 09-101-1M143 C 1ST FLOOR PLUMBING PLAN 09-101-1M146 H 1ST FLOOR PIPING PLAN 09-101-1M148 — 1ST FLOOR PLUMBING PLAN 09-101-1 M260 C FIRE PROTECTION FIRST FLOOR PLAN 09-101-1M298 1ST FLOOR FIRE PROTECTION PLAN 09-101—RFM148 — ROOF PLUMBING PLAN 09-101-M317 A CONTROL DIAGRAMS 09-101—M607 A PLUMBING DETAILS AND SECTIONS 09-101—M616 — SPRINKLER RISER DIAGRAM PS-5830—M2c — REFRIGERATION NOTES PS-5830—M1v — EQUIPMENT SCHEDULE PS-5830—M3b — SCHEMATIC PS -5830-1M98 — 1ST FLOOR REFRIGERATOR EQUIPMENT PLAN PS-5830-UGM98 — UNDERGROUND GLYCOL PIPING PS -5830-1 M458 — ENLARGED MECHANICAL ROOM PLAN & DETAILS PS -5830-M612 - STANDARDS PS -5830—M613 — STANDARDS PS-5830—RFM98 — ROOF PLAN ELECTRICAL 09-101-1 E2C A 480Y/277V POWER DISTRIBUTION FLOOR PLAN 09-101-1E2D A 480Y/277V POWER DISTRIBUTION FLOOR PLAN 09-101-1 E43 F PARTIAL 1ST FLOOR LIGHTING PLAN 09-101-1E48 PARTIAL 1ST FLOOR LIGHTING PLAN 09-101-1 E96 U 120V/208Y POWER PLAN 09-101-1E98 — PARTIAL 1ST FLOOR 208Y/120V POWER PLAN 09-101-1E143 M PARTIAL 1ST FLOOR 480Y/277V POWER PLAN 09-101-1 E144 C PARTIAL 1ST FLOOR 480Y/277V POWER PLAN 09-101-1E146 T 277V/480Y POWER PLAN 09-101-1 E148 — PARTIAL 1ST FLOOR 480Y/277V POWER PLAN 09-101-1E448 - PARTIAL 1ST FLOOR COMMUNICATIONS PLAN 09-101-1 E585 A ANNEX GENERATOR ROOM PARTIAL PLAN 09-101—RFE48 — PARTIAL ROOF LIGHTING • PLAN 09-101—RFE98 — PARTIAL ROOF 208Y/120V POWER PLAN 09-101—RFE148 — PARTIAL ROOF 480Y/277V POWER PLAN 09-101-E4S72 A ONE LINE DIAGRAM — SUBSTATION 72 09-101—E4S73 A ONE LINE DIAGRAM — SUBSTATION 73 09-101-E5B B EMERGENCY AND STAND—BY POWER ONE—LINE 09-101—E613 — FREEZER ONE—LINE DIAGRAM 09-101-E615 — FREEZER ELEVATION DETAIL 09-101-SK—E616 — FREEZER SCHEDULE 09—YD—E122 — ELECTRICAL SITE PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION %BO33 ISSUED FOR CONSTRUCTION APRIL 12, 2013 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER DLR Group Architecture Engineering Planning interiors REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DC FREEZER ADDITION J#16262 DLR GROUP VW 04.12.13 Q� BOE/NG' d-- REGISTERED ARCHITECT AW b 0 KRUG ATE OF VASHINGTt ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DLR GROUP CHECKED VW DATE 04.12.13 04.12.13 SUBTITLE SHEET INDEX CURRENT REVISION J#16262 SYMBOL DATE 04.12.13 APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE DC FREEZER ADDITION BUILDING 09-101.1 ARCHITECTURAL MASTER COL. Z/21-22.5 DEV. CENTER, WA SHEET GOA JOB NO. J#16262 COMP NO. DWG NO. 09 -101 -GOA MJANES: 4/8/2013 2:38:36 PM LEGEND SYMBOLS MATERIAL SY 1 BOLS ABBREUTATIO NS GENERAL NOTES & AND IN INCH AB AT INCL INCLUDED(D) (ING) ANCHOR BOLT JT JOINT ACP ACOUSTICAL CEILING PANEL ACT ACOUSTICAL CEILING TILE K KIP(S) ADJ ADJACENT KO KNOCK OUT AFF ABOVE FINISHED FLOOR AGG AGGREGATE L LENGTH AL ALUMINUM LB LAG BOLT LEN LENGTH) ALT ALTERNATE LF LINEAL FEET ALUM ALUMINUM ANCH ANCHOR, ANCHORAGE LL LIVE LOAD APA AMERICAN PLYWOOD ASSOC. LWR LOWER APPD APPROVED MATL MATERIAL APPROX APPROXIMATE MAX MAXIMUM ASTM AMERICAN SOCIETY OF MB MACHINE BOLT TESTING MATERIALS 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF TUKWILA PRIOR TO COMMENCING CONSTRUCTION. 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUDS ON EACH INFORMATION OR WORKSHEET. IF THERE IS O(WHETHERCLOUD CLOUDEDOR NOA SHEET THE T)REFERRED TORE SHEET IS FROMWITHIN A CLOUD N THE SCOPE OF KIS INCLUDED IN THE SCOPE OF WORK (I.E. - A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE TTI IST -TfITTTI 1TTIEARTH, DIRT, COMPACTED SECTION/DETAIL DESIGNATION BUILDING, WALL SECTIONS #X # X # AND DETAIL REFERENCES ... .�- ' lriSIS .9 STONE, GRAVEL, POROUS FILL �/////////////////,� BRICK, COMMON SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM ELEVATION REFERENCE FMMMM1 CERAMIC TILE INTERIOR / /r ' CONCRETE MBR MEMBER BTWN BETWEEN MTL METAL BLDG BUILDING MFR MANUFACTURE(R) BLKG BLOCKING MIN MINIMUM BO BOTTOM OF MISC MISCELLANEOUS BOT BOTTOM MO MASONRY OPENING MT MOUNT(ED) (ING) C CHANNEL MTL METAL CB CATCH BASIN REVIEWED FOR CODE COMPL APPROVED JUN 0 5 2013 City of Tulwila BUILDING ®MSI® -��.-- . ANG- - JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR TO SUBMITTING ANY REQUESTS FOR INFORMATION (RFIs). 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. MITITITITITITITITITIN INSULATION: BATT, LOOSE FILL, BLANKET SHEET NUMBER WHERE DETAILED >,>,,,>,>,>,,>,>,>,,,>,> `.,`.,`o�`.,�`o�`%�`.,�`o�`o�`o�`o�`•/ EARTH, DIRT, UNDISTURBED SHEET NUMBER REFERENCED FROM �---- REFERENCE TO DETAIL/ENLARGED PLAN INSULATION: RIGID #X # MI X # l \ __ � DETAIL DESIGNATION //�/////�//�i ALUMINUM r%�!%�///���A BRASS, BRONZE, COPPER CC CENTER TO CENTER N NORTH (COORDINATE) CEM CEMENT NF NEAR FACE 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE CF CUBIC FEET NIC NOT IN CONTRACT DRAWINGS. CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED NO. NUMBER 9. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, CG CORNER GUARD NOM NOMINAL METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. CJ CONTROL JOINT NTS NOT TO SCALE CL CENTER LINE 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS CLG CEILING OA OVERALL DIMENSIONED OTHERWISE. CLR CLEARANCE) 0/C ON CENTER 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED COL COLUMN OD OUTSIDE DIAMETER OTHERWISE. COMP COMPRESS(ED) (ION) OF OUTSIDE FACE CONC CONCRETE OFCI OWNER FURNISHED CONTRACTOR INSTALLED 12. PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL CONN CONNECTION OFOI OWNER FURNISHED OWNER INSTALLED DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. CONST CONSTRUCTION OPG OPENING SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT CONT CONTINUOUS, CONTINUE OPP OPPOSITE, OPPOSITE HAND PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. CONTR CONTRACT(OR) PAR PARALLEL CT CERAMIC TILE PCC PRECAST CONCRETE 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL CTSK COUNTERSUNK PCF POUNDS PER CUBIC FOOT AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. CY CUBIC YARD(S) PERF PERFORATE(D) COORDINATE ALL ROUGH -IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 0, DIA DIAMETER PERIM PERIMETER DBL DOUBLE PG PATTERN GLASS 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION DEMOL DEMOLISH, DEMOLITION PL PLATE MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. DEP DEPRESSED PLAM PLASTIC LAMINATE DIA DIAMETER PLYWD PLYWOOD 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER DIAG DIAGONAL PNL PANEL PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. DIM DIMENSION PREST PRESTRESS(ED) DL DEAD LOAD PRF PREFORMED 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING DN DOWN PSF POUNDS PER SQUARE FOOT MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. DS DOWNSPOUT PSI POUNDS PER SQUARE INCH 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR DWG DRAWING PT POINT, PAINT PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO PVC POLYVINYL CHLORIDE MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL E EA EAST (COORDINATE) EACH R RADIUS (CURVATURE) BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. EB EXPANSION BOLT R RISER 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN EF EACH FACE RB RESILIENT BASE REQUIRED FIRE RATING OF THE PARTITION. EJ EXPANSION JOINT REF REFERENCE, REFER TO 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND EL ELEVATION REINF REINFORCE(D) (ING) ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN THE ELEV ELEVATION REQ REQUIRE(D) (ING) CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL EQ EQUAL REV REVERSE, REVISION(S), REVISED COMPONENTS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS. EW EACH WAY RH RIGHT HAND 20. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL EX EXISTING RO S ROUGH OPENING SOUTH (COORDINATE) FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, EXT EXPOSED EXTERIOR CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. SECT SECTION 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND FAS FASTEN(ER)SF SQUARE FEET ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE FE FIRE EXTINGUISHER SHT SHEET LIMITS OF THE ARCHITECTURAL DRAWINGS. FEC FIRE EXTINGUISHER CABINET SIM SIMILAR 22. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.0.. WHERE THEY FF FINISHED CEILING SQ SQUARE CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE FF FACTORY FINISH SS SOLID SURFACING BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT FF FINISHED FLOOR SST STAINLESS STEEL EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE FGR FINISH GRADE ST STRUCTURAL TEE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, FH FIRE HYDRANT STD STANDARD U.N.O. FIN FINISH(ED) STL STEEL 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND FND FOUNDATION STR STRUCTURAL ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS SYM SYMMETRY,SYMMETRICAL MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, FOC FACE OF CONCRETE FOF FACE OF FINISH SYS SYSTEM CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES T&B TOP AND BOTTOM OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO FOIC FURNISHED BY OWNER/ T&G TONGUE AND GROOVE INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. INSTALLED BY CONTRACTOR TEMP TEMPORARY FO FINISHED OPENING 24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE FRO FOR REFERENCE ONLY THK THICK(NESS) WITH ALL SAFETY CODES, REGUALTIONS AND BOEING REQUIREMENTS. FT FOOT TOC TOP OF CURB FTG FOOTING TOC TOP OF CONCRETE 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF TOL TOLERANCE WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE FUT FUTURE TOS TOP OF STEEL AREA OF WORK. SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN FV FIELD VERIFY TS STRUCTURAL TUBE COMPLIANCE W/ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL GA CRFG GAGE GLASS FIBER REINFORCED GYPSUM T(P TYPICAL NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. GALV GALVANIZED 26. THE CONTRACTOR SHALL INSURE THAT THE ELEVATOR CAR, EQUIPMENT ROOM, EQUIPMENT LAYOUT UBC UNIFORM BUILDING CODE AND HYDRAULIC ELECTRICAL ROUTING FULLY MEETS STATE OF WASHINGTON CODES AND GC GENERAL CONTRACTOR UL UNDERWRITERS' LABEL / COMPLIANCE. FULLY COORDINATE WITH ARCHITECT PRIOR TO FABRICATION AND INSTALLATION. UNO UNLESS NOTED OTHERWISE GI GALVANIZED IRON UPR UPPER 27. AT LOCATIONS WHERE STRUCTURE, PIPING, DUCTWORK, CABLETRAY, OR CONDUIT PENETRATES GR GRADE WALLS AND ARE EXPOSED TO VIEW, CONTRACTOR SHALL COPE AS CLOSELY AS POSSIBLE TO THE GT GROUT VB VAPOR BARRIER MEMBER AND INSTALL CONTINUOUS CAULKING AROUND MEMBER AND PAINT OR PROVIDE GWB GYPSUM WALL BOARD VC VINYL COMP. TILE ESCUTCHEONS MATCHING WALL COLOR AT PENETRATIONS. VERT VERTICAL 28. FOR CONSISTENCY ALL CONSTRUCTION NOTES ("FLAG NOTES") FOR EACH GROUP: PLAN AND HDNR HARDENER VIF VERIFY IN FIELD RCP'S, ARE SHOWN IN THEIR ENTIRETY. ALL CONSTRUCTION NOTES MAY NOT BE REFERENCED ON HDWD HARDWOOD W WEST (COORDINATE) EVERY SHEET. HDWR HARDWARE W WIDE FLANGE HG HIGH GRADE W WIDTH, WIDE 29. FRAME TYPES ARE TYPICALLY DRAWN LOOKING FROM THE OUTSIDE OR CORRIDOR SIDE UNO. RECEIVED HM HOLLOW METAL WC WATER CLOSET CITY OF TUKWILA HORZ HORIZONTAL WD WOOD � �,• 1. 0 a3 232013 Mr MBER WHERE DETAILED (IF ESAME ET UAS SHEET REFERENCED FROM) SECTION DETAIL DESIGNATION / Allik %/ ./A METAL, STEEL, IRON . ; , •; :,: _r, _ : , ..::. PLASTER: SAND, CEMENT, GROUT XXXXX XXXXX SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM NORTH ARROW :-..:•••!:` :v• '•''s �` :`I PLASTER: GYPSUM WALL BOARD ) ) J WOOD: FINISH WOOD: ROUGH CONTINUOUS ELEVATION DATUM WOOD: INTERRUPTED BLOCKING OR SPOT ELEVATION CM CEILING HEIGHT A.F.F. // 1/ 4 XXXXXX ROOM NAME PLYWOOD: SMALL SCALE XXXX ROOM NUMBER I PLYWOOD: LARGE SCALE ® DOOR NUMBER - -- GRID/GRID BUBBLE AND CENTERLINE - - ITEMS TO BE REMOVED 1 CONSTRUCTION "FLAG" NOTE FOR SPECIFIC CONSTRUCTION DIRECTIVE GENERAL "BOAT" NOTE FOR / WALL TYPE: CONCRETE MASONRY (CMU) �/��.��I WALL TYPE: STEEL STUD I-- '� WALL TYPE: WOOD STUD SPECIFIC OR EXISTING HISTORICAL WALL TYPE: EXISTING INFORMATION. © WINDOW FRAME TYPE TYPE: WALL REMOVAL 8EXP © PARTITION/WALL TYPE 7 END WALL GUARD 3 WALL TYPE PARTITION (7'-0" HIGH) ii ii WALL TYPE: GLASS CORNER GUARD I I ( CPT -1) FINISH DESIGNATION VCT REVISION CLOUD WITH REVISION LETTER "BEAK" f -j CPT FLOOR MAT'L TRANSITION .. FEO EEC FIRE EXTINGUISHER FIRE EXTINGUISHER & CABINET 0 o SUPPLY AIR DIFFUSER RETURN AIR GRILLE LIGHT FIXTURE. (PENDANT MOUNTED) ( � FLOURESCENT t FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL)CIRCUIT O RECESSED OR PENDANT LIGHTING FIXTURE o RECESSED OR PENDANT LIGHTING FIXTURE FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT i WALL SCONCE 1 a WALL SCONCE 2 ® EXIT SIGN (CEILING UNIT) I-0 EXIT SIGN (WALL MOUNT) 1-01 EXIT SIGN W/ DIRECTIONAL ARROW IF REQ'D HS HIGH STRENGTH W%WITH HT HEIGHT 0 WITHOUT WWF WELDED WIRE FABRIC IBC INTERNATIONAL BLDG. CODE NOTE REFER TO THE COLOR AND ID INSIDE DIAMETER MATERIAL SCHEDULE FOR ADDITIONAL ID INSIDE DIMENSION FINISH AND ISSUED FOR C APRIL 12, 20 13 MAY , .ww PERMIT CENTER „., DLR Group: Architecture Engineering Nanning I tWriors DESIGNATIONS/ABBREVIATIONS SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ?..___AirAtillEZA// ® 1;EOi8TID AL i� TE F ARCHITECT ` 0 I I SI AVM= I . ACCEPTABILITY THIS DESIGN AND/OR IS APPROVED DRAWN DLR GROUP DATE 04.12.13 SUBTITLE KEY SHEET CURRENT REVISION J#16262 SYMBOL - DATE 04.12.13 CHECKEDSPECIFICATION V. WIGEN 04.12.13 - DC FREEZER ADDITION J#16262 DLR GROUP VW 04.12.13 SHEET G 1 ENGINEER TITLE DC FREEZER ADDITION BUILDING 09-101.1 ARCHITECTURAL MASTER DEV. CENTER, WA APPROVED BY DEPT. DATE CHECKED JOB NO. 6262 COMP NO. APPROVEDJ#1 DWG No. 09-101-G1 APPROVED C4 M CNI CO w -101 SSM Ni 6.6± E 1, x,075.8± RIM = 14.2± IE8"=867(S) IE 10" 8.7± (SW, NE) EXI 9-101 CONN TO EXIST W OIL WATER SEPARATOR 27 GPM N 190,914.81 E 1,279,11 IE 4" = 12.67 (N, S N 190,971± E 1,279,035.9± (1) 90° BEND W/ HTB CONN TO EXIST FW' N 190,968*.. E 1279,033: .,(1) 90° BEND W/ (1)19" GY. N 190,910.54 E 1,279,112.09 N 190,910.54 UTILITY CROSSING IE SS' .....TO.P...W TOP: EL SSMH:::' N 190,933.93 = 11.33 8.47 EC DUCT BANK E 1,279,112.09 IE 6"=11.43 N 190,891.85 CO CONN TO BLDG SS IE6"= 11.67 SEE MECH FOR CONT CONN TO BLDG, SEE MECH FOR CONT 10.E ;CONN TO BLDG SS VENT, SEE MECH FOR CONT CONN TO BLDG SS, SEE MECH FOR CONT E 1,279,109.81 N 190,888.22 (1) 11.25° BEND W/ HTB E 1,279,130.20 (1) 10"x8" TEE W/ HTB FDC AT FACE OF BLDG, ! SEE MECH FOR CONT—•-<•:::: MAGNUSSON KLEMENCIC SYM ORIG ASSOCIATES REVISION Structural + Civil Engineers 1301 Fifth Avenue, Suite 3200 Seattle Washington 98101-2699 T: 206 292 1200 F: 206 292 1201 BY APPROVED DATE SYM REVISION E 1,279,137.22 RIM '= 14.49 IE 41 9.94 (S), SEE N IE 6"i = 11.00 (SW) IE8"9.72 (N) 190,899.04 1,279,145.84 11.25 BEND W/ N E (1) BOLLARD N 190,912.30 E 1,279,175.34 PIV N 190,908.57 U TILITY CROSSING OTE 8 H IE SSFM = UNKNOWN TOP ELEC DUCT BAN UTILITY CROSSING TOP W = 8.54 TOP ELEC DUCT BAN 190,910.42 1,279,173.26 90° BEND W/ HTB E 1,279 174.02 BY 11.22 11.12 REVIEWED FOR CODEAPPROVED CE JUN 0 5 2013 City of Tukwila BUILDING DIVISION APPROVED UTILITIES SITE PLA SCALE 1'=30'- DATE FREEZER BUILDING - EARLY UTILITIES 16262 MKA 01.28.13 (NOTE: SEE 13 YARD DRAWINGS FOR THIS AREA) ?)LAOE/NG' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN C. MCCARTNEY CHECKED DATE SUBTITLE F LEGE\D cw SAN SSFM G3O33 FIRE WATER COLD WATER SANITARY SEWER SANITARY SEWER FORCE MAIN SANITARY SEWER MANHOLE (SSMH) CLEAN OUT (CO) GATE VALE (GV) HORIZONTAL THRUST BLOCK (HTB) PER CITY OF TUKWILA TYPICAL DETAIL WS -12A BOLLARD CAP GE\PAL \OTES 1. SEE SHEET C2A FOR UTILITY AND GENERAL NOTES. 2. UTILITY TRENCH PER CITY OF TUKWILA TYPICAL DETAIL DS -14A. BELOW TYPICAL TRENCH SECTION, INSTALL FILTER FABRIC AND 6" OF ROCK AS REQUIRED BY THE GEOTECH REPORT. 3. 10 INCH WATER LINE IS BOEING PRIVATE FIRE LOOP THAT IS CONNECTED TO, AND ISOLATED FROM, CITY OF TUKWILA WATER MAIN BY MEANS OF THREE DOUBLE DETECTOR CHECK VALVES ALONG EAST MARGINAL WAY. REFERENCE DRAWI\GS CO\S-RUCTION \OTES INSTALL NEW SANITARY SEWER PIPE. INSTALL NEW COLD WATER PIPE. INSTALL NEW FIRE WATER PIPE. INSTALL BOLLARD PER CITY OF TUKWILA TYPICAL DETAIL WS -14. INSTALL NEW SANITARY SEWER FORCE MAIN PIPE. INSTALL SANITARY SEWER MANHOLE PER CITY OF TUKWILA TYPICAL DETAIL SS -05. INSTALL SANITARY SEWER CLEAN OUT PER CITY OF TUKWILA TYPICAL DETAIL SS -03. EXISTING SANITARY SEWER FORCE MAIN INVERT UNKNOWN. INSTALL ASCENDING AT CONSTANT SLOPE FROM CONNECTION LOCATION, NORTH TO MANHOLE. MANHOLE CONNECTING INVERT SHALL BE NO HIGHER THAN 9.94' UNLESS APPROVED BY BOEING. INSTALL 27 GPM COALESCING PLATE TYPE OIL WATER SEPARATOR. INSTALL 2" VENT BETWEEN OIL WATER SEPARATOR AND BUILDING. ISSUED FOR CONSTRUCTION JANUARY 28, 2013 UTILITIES SITE PLAN C91 <:..:: C290 292 C293 C294. 9-99 9-911 C29 9-101 MAY 232013 PERMIT CENTER SITE KEY PLAN CURRENT REVISION 16262 SYMBOL° SIG DATE 01.28.13 ENGINEER A. J. VANDERMUSS CHECKED R. M. GREENE APPROVED TITLE CIVIL MASTER 9-101 DC FREEZER ADDITION SITE -09 -YD SHEET C302 JOB NO. 16262 COMP NO. DEV. CENTER, WA DWG ND. 09 -YD -C302 VAC JA\ CAL VAC LFCF\D GENERAL SYMBOL DESCRIPTION 0 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN k 24x12 - 24x12 I 1 24x12 i>„1 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST HUMIDITY SENSOR ROUND DUCT, NUMBER INDICATES DIAMETER I) 240 4 240 OCCUPANCY SENSOR 4S o OVAL DUCT, FIRST NUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER 0 24x120 4 24x12 i PRESSURE SENSOR HIGH/LOW LIMIT SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY i 'ice\ EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING TOWARDS $ ro,,, MIIIIL% FF-Zji:)_ EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND, ELBOW FACING AWAY EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY 1 1 TRANSITION RECTANGULAR TO RECTANGULAR HEEL TAP OR LOW LOSS TRANSITION AT TAKE OFF FROM OVAL TO ROUND OR ROUND TO ROUND ,y I TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL a, CONICAL SPIN -IN W/ VOLUME DAMPER (NOT SHOWN) NALf UP DUCT OFFSET UP OR DOWN 1 �-- t DN CVOPPOSED BLADE DAMPER -IC. PARALLEL BLADE DAMPER +-1----+ VOLUME DAMPER t—r+ DUCT DAMPER, MOTOR OPERATED (ELECTRIC) BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) BDD AD OR AP ACCESS DOOR ACCESS PANEL (AD(AP)) OR IN RECTATURNNG NGULAR DVANES SQUARE ELBOW WITH RECTANGULAR DUCT, LONG RADIUS ELBOW ----=1-1) El —� SIDEWALL SUPPLY AIR GRILLE OR REGISTER N CEILING DIFFUSER FLEXIBLE DUCT GENERAL SYMBOL DESCRIPTION SUPPLY AIR FLOW DIRECTION, POSITIVE PRESSURE RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION, NEGATIVE PRESSURE GENERAL SYMBOL DESCRIPTION 0 TEMPERATURE SENSOR, WALL THERMOSTAT, WALL T 0 HUMIDITY SENSOR 0 CARBON DIOXIDE SENSOR, WALL 0 OCCUPANCY SENSOR 4S o DUCT TYPE SMOKE DETECTOR 0 PRESSURE SENSOR OH/L PRESSURE SENSOR HIGH/LOW LIMIT DIFFUSER AND GRILLE CALLOUTS SUPPLY GRILLE, MARK SG SG -200 \ DESIGN CFM, SEE SCHEDULE FOR DIFFUSER AND GRILLE NECK SIZE, TYPICAL CD -CFM = CEILING SUPPLY DIFFUSER FSD-CFM = FLOOR SUPPLY DIFFUSER SG -CFM = SUPPLY GRILLE ABBREVIATIONS ABBREVIATION DESCRIPTION A MV AD ADD AF AFF AMS AP APPROX ARCH AUD AVG BI BDD BFP BHD BHP BLDG BOD BOP BOS BTU BTU H BW C Cv 'C CAP CC CCW CFM CI CO COMB CONN CONT COTG CPLG CRU CRAC CW DA DB DBD DEG ' DI DIA 0 DIM DL DN DS DWG dB DP (E) EA EAT EDC EFF ELL ELEC ELEV, EL ENT ESP ETP EVAP EWT EXH EXIST EXT 'F F FC FD FLR FCO FOB FOF FOIC FOT FPM FPWH FS FT FV FW GAL GPM GALV GA GCO ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR AIR MEASURING STATION ACCESS PANEL APPROXIMATELY ARCHITECTURAL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACKFLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE - DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CLEANOUT COMBUSTION CONNECTION CONTINUED/CONTINUATION CLEAN OUT TO GRADE COUPLING COMPUTER ROOM UNITS COMPUTER ROOM AIR CONDITIONING UNITS DOMESTIC COLD WATER DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DEGREES DUCTILE IRON DIAMETER DIMENSION DELUGE DOWN DOWNSPOUT DRAWING DECIBELS DRY PIPE EXISTING EXHAUST AIR / EACH ENTER AIR TEMPERATURE ('F) EVERETT DELIVERY CENTER EFFICIENCY ELBOW ELECTRICAL ELEVATION ENTERING EXTERNAL STATIC PRESSURE ELECTRONIC TRAP PRIMER EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE - DEGREES FAHRENHEIT FREEZE STAT FORWARD CURVE WHEEL FIRE DAMPER, FLOOR DRAIN FLOOR FLOOR CLEAN OUT FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FREEZE PROOF WALL HYDRANT FLOW SWITCH, FIRE SPRINKLER (WET PIPE) FEET FACE VELOCITY FPM FIRE WATER GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE GRADE CLEANOUT ABBREVIATIONS ABBREVIATION DESCRIPTION HC HD HORIZ HP HPC HR HVAC HPU HTG HW Hz D GV NSUL N NSTAN NT KW KVA LAT LBS, # LVG LWT MA MAX MBH MCC MECH MIN MOV MTD, MTG NC NEC NIC NO NTS NPSH OA OBD OCC OF OS&Y OD OVHD PBD PCD PD/oP PDI PIV P LS POC POS PRESS PRV PS PSIG PSV RA RECT REF REV RH RM ROT RPM RPBP RQD RTN SA SAN SCFM SG SHC SHF SHT SO SOV SP SPEC SQ SS STL STRUC SW SUCT HEATING COIL HEAD - FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING HEAT PUMP UNIT HEATING DOMESTIC HOT WATER HERTZ NSIDE DIMENSIONS NLET GUIDE VANE NSULATION NCHES NSTANTANEOUS NTERMEDIATE KILOWATT KILOVOLT -AMPERE LEAVING AIR TEMPERATURE (T) POUNDS LEAVING LEAVING WATER TEMPERATURE (T) MIXED AIR MAXIMUM BTU PER HOUR X 1000 MOTOR CONTROL CENTER MECHANICAL MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NORMALLY CLOSED NATIONAL ELECTRIC CODE NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OCCUPANCY SENSOR OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER OVERHEAD PARALLEL BLADE DAMPER PUMPED CONDENSATE DRAIN PRESSURE DROP OR DIFFERENTIAL PRESSURE PLBG. & DRAINAGE INSTITUTE POST INDICATOR VALVE DUCT PRESSURE LIMIT SWITCH POINT OF CONNECTION POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE- POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE REVISED RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER REQUIRED RETURN SUPPLY AIR SANITARY SEWER CUBIC FEET OF AIR, AT STANDARD CONDITIONS SUPPLY GRILLE SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SHEET SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SPECIFICATION SQUARE STAINLESS STEEL STEEL STRUCTURAL SOCKET WELD, SITE WATER SUCTION ABBREVIATIONS ABBREVIATION DESCRIPTION TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP V VAV VD VP VERT VTA VTR ID IE W WB WG WCO WS WSEC WH WHA TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE, TRAP PRIMER TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL VENT VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF INSIDE DIAMETER INVERT ELEVATION WASTE WET BULB TEMPERATURE WATER GAUGE WALL CLEAN OUT WET STAND PIPE WASHINGTON STATE ENERGY CODE 2009 WATER HEATER WATER HAMMER ARRESTOR V' G t3 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION U33 ISSUED FOR CONSTRUCTION APRIL 12, 2013 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER Wood iiiHarbinqer 3009 with Ave NE, Suite too Bellevue WA 98004 425.628.6000 — woodharbinger.com SYM REVISION BY APPROVED DATE SYM REVISION APPROVED DATE DC FREEZER ADDITION J# 16262 WH GV 04.12.13 ,�BOE/NG' D� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G. VERSEGI DATE 04.12.13 CHECKED E. LARSON 04.12.13 SUBTITLE ENGINEER G. VERSEGI 04.12.13 CHECKED E. LARSON APPROVED 04.12.13 APPROVED TITLE MECHANICAL MASTER HVAC LEGEND DC FREEZER ADDITION CURRENT REVISION SYMBOL J# 16262 DATE 04.12.13 BUILDING 9-101 D.C. SHEET M1 JOB N0. 16262 COMP N0. DWG N0. 9-101-M1 KHON: 02/13/13 VFCHA\ CAL DI \G LI -GI -\D GENERAL SYMBOL DESCRIPTION O BREAK IN PIPE 1-,- I CROSSING LINES, NO CONNECTION DF 11 Co DIRECTION OF FLOW ELECTRIC WATER COOLER SLOPE I. DIRECTION OF SLOPE, DOWN CLEAN OUT, WALL WP EQUIPMENT MARK NUMBER Q ,-EXIST EXISTING WORK O LAV EXISTING TO BE REMOVED /////// FUNNEL DRAIN HIDDEN OR BELOW GRADE COwc —o0' IN-LINE RECIRCULATING PUMP COOLING WATER RETURN INSULATED PIPE $ g- WASTE RECEPTOR, ROOF CRV INSULATED PIPE WITH ELECTRIC HEAT TRACING jI co SITE WATER SW FD NEW WORK 0 4FOC POINT OF CONNECTION CONDENSER WATER RETURN PUMP —.o FIXTURES SYMBOL DESCRIPTION O CIRCULAR WASHFOUNTAIN 1/4 BEND DRINKING FOUNTAIN ARGON GAS DF 11 Co 112 EWC ELECTRIC WATER COOLER 03 EWCH ELECTRIC WATER COOLER FOR HANDICAPPED CLEAN OUT, WALL FD FLOOR DRAIN Q Q LAv LAVATORY, ROUND COUNTER MOUNT O LAV LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT WI FUNNEL DRAIN O COwc WATER CLOSET, FLUSH VALVE, WALL HUNG —CLWR— COOLING WATER RETURN TRENCH DRAIN IIIL•iI jI O WR WASTE RECEPTOR, ROOF CRV WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT jI co SITE WATER SW FD FLOOR DRAIN 0 nil FD FLOOR DRAIN ABOVE CONDENSER WATER RETURN —CDWS— CONDENSER WATER SUPPLY _10 DOMESTIC COLD WATER CW PIPE ELBOW, TURNED DOWN OR AWAY DRAIN WASTE FITTINGS SYMBOL DESCRIPTION ) COMPRESSED AIR, PLANT 1/4 BEND t ARGON GAS CLEAN OUT, EXPOSED 11 Co FCO CLEAN OUT, FLOOR UNION, SCREWED CONDENSATE RETURN (GRAVITY) CLEAN OUT, WALL WCO CONDENSATE DRAIN CD FFD FUNNEL FLOOR DRAIN O -CHWR- CHILLED WATER RETURN FUD FUNNEL DRAIN O CLEAR WATER DRAIN LATERAL —CLWR— COOLING WATER RETURN TRENCH DRAIN IIIL•iI jI O WR WASTE RECEPTOR, ROOF CRV WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT jI co SITE WATER SW FD FLOOR DRAIN 0 nil FD FLOOR DRAIN ABOVE PIPE IDENTIFICATION SYMBOL DESCRIPTION ) COMPRESSED AIR, PLANT A RD ARGON GAS AR BUSHING ACID WASTE AW UNION, SCREWED CONDENSATE RETURN (GRAVITY) C X111- CONDENSATE DRAIN CD FLEXIBLE PIPE CONNECTION CHEMICAL FEED CF -CHWR- CHILLED WATER RETURN —CHWS— CHILLED WATER SUPPLY CLD CLEAR WATER DRAIN BFP —CLWR— COOLING WATER RETURN —CLWS— COOLING WATER SUPPLY PCD CORROSION RESISTANT VENT CRV CRW CORROSION RESISTANT WASTE SITE WATER SW COOLING TOWER FILTER RETURN — CTFR — — CTFS — COOLING TOWER FILTER SUPPLY —CDWR- CONDENSER WATER RETURN —CDWS— CONDENSER WATER SUPPLY _10 DOMESTIC COLD WATER CW PIPE ELBOW, TURNED DOWN OR AWAY DRAIN D PIPE GUIDE DEIONIZED WATER DI PIPE HANGER DISTILLED WATER DW Y FIRE LINE, AHEAD OF ALARM VALVE F I FIRE HOSE CABINET PIPING FH a FUEL OIL RETURN FOR - FUEL OIL SUPPLY FOS -MAV FUEL OIL VENT FOV MOTOR OPERATED VALVE FILTERED WATER FW G NATURAL GAS PIPE TEE, UP OR TOWARD NITROGEN DROP CONDENSATE, STEAM (HIGH PRESSURE) HPC —I*— CONDENSATE RETURN (HIGH PRESSURE) HPR PETE'S PLUG, WITH BALL VALVE STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) HPS —HPWS— HEAT PUMP WATER SUPPLY -HPWR- HEAT PUMP WATER RETURN SOLDERED FITTING HEAT RECOVERY SUPPLY HRS HEAT RECOVERY RETURN HRR PRESSURE REGULATING VALVE (SELF CONTAINED) DOMESTIC HOT WATER SUPPLY HW PRESSURE RELIEF VALVE / SAFETY VALVE DOMESTIC HOT WATER CIRCULATING HWC HWR HEATING WATER RETURN QUICK CLOSING VALVE, FUSIBLE LINK - HEATING WATER SUPPLY HWS INSTRUMENT AIR IA ii INDIRECT DRAIN ID SWING CHECK VALVE WITH FLOW INDUSTRIAL WASTE IW A LIQUID NITROGEN LN2 CONDENSATE, STEAM (LOW PRESSURE) LPC LIQUID PETROLEUM GAS LPG STEAM SUPPLY (LOW PRESS, 0-15 PSIG) LPS CONDENSATE, STEAM (MEDIUM PRESSURE) MPC STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) MPS OILY WASTE OW —PCWS— PROCESS COOLING WATER SOURCE —PCWR— PROCESS COOLING WATER RETURN CONDENSATE RETURN (PUMPED) PR PIPE IDENTIFICATION SYMBOL DESCRIPTION ) PROCESS WATER PW RD ROOF DRAIN THERMOMETER, LINE MOUNT BUSHING REFRIGERANT DISCHARGE RDS UNION, SCREWED REFRIGERANT HOT GAS RHG X111- REFRIGERANT LIQUID RL FLEXIBLE PIPE CONNECTION REFRIGERANT SUCTION (GAS) RS B RAIN WATER LEADER RWL HOSE BIBB - NON FREEZE SPRINKLER LINE S BFP SANITARY WASTE ABOVE GRADE OR FLOOR SAN BALANCE VALVE WITH METERING PORTS PUMPED CONDENSATE DRAIN PCD STM STEAM SUPPLY 1$ 1 _11 SR SITE WATER SW - TP TRAP PRIMER COOLING COIL CHILLED WATER VENT V row! PROCESS VACUUM VAC _10 VACUUM PUMP DISCHARGE VPD PIPE FITTINGS SYMBOL DESCRIPTION ) BELL & SPIGOT ) �I BLIND FLANGE THERMOMETER, LINE MOUNT BUSHING ► e / e UNION, SCREWED EXPANSION JOINT ANGLE GLOBE VALVE, ELEVATION / PLAN X111- FLANGED FITTING WELD SYMBOL OR REFERENCE (MAY BE OMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE FLEXIBLE PIPE CONNECTION :::•: MA" B HOSE BIBB SHB HOSE BIBB - NON FREEZE —X— PIPE ANCHOR BFP PIPE CAP SCREWED OR SOLDER JOINT ] BALANCE VALVE WITH METERING PORTS PIPE CAP, WELDED OR GROOVED mo-- BALANCE VALVE W/0 METERING PORTS PIPE CROSS 1$ 1 _11 SR PIPE ELBOW, 90' SHORT RADIUS . } PIPE ELBOW, 90' LONG RADIUS COOLING COIL CHILLED WATER —'' PIPE ELBOW, REDUCING row! PIPE ELBOW, 45' —I -N _10 PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW, TURNED DOWN OR AWAY I D PIPE GUIDE - /-►♦ PIPE HANGER _IA_ X Y PIPING MATERIAL CHANGE, X TO Y -1:01-/-tal-GLOBE I PIPE PLUG a PIPE REDUCER CONCENTRIC ► • PIPE REDUCER ECCENTRIC -MAV i— PIPE SUPPORT MOTOR OPERATED VALVE PIPE TEE, STRAIGHT NEEDLE VALVE PIPE TEE, UP OR TOWARD NITROGEN DROP ON PIPE TEE, DOWN OR AWAY —I*— PETCOCK SCREWED FITTING OR AS SPECIFIED PETE'S PLUG, WITH BALL VALVE wi- SEISMIC HANGER S -X---"A� SEISMIC LOOP PRESSURE GAUGE WITH VALVE SOLDERED FITTING PIPE FITTINGS SYMBOL DESCRIPTION Ai SOLVENT CEMENT F' SPRING HANGER 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR THERMOMETER, LINE MOUNT UNION, FLANGED AIR DROP - HOSE, SIMPLEX / DUPLEX e / e UNION, SCREWED Imo— ANGLE GLOBE VALVE, ELEVATION / PLAN WELDED FITTING AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) WELD SYMBOL OR REFERENCE (MAY BE OMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE HOSE KIT TRAP SEAL PRIMER VALVE MA" AUTOMATIC AIR VENT (WITH DRAIN) PIPING SPECIALTIES SYMBOL DESCRIPTION Ai 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR TEST PLUG OPENING OF PLUG WELDS OR 77/1; 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR THERMOMETER, LINE MOUNT b. / , AIR DROP - HOSE, SIMPLEX / DUPLEX e / e AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX CE1 ANGLE GLOBE VALVE, ELEVATION / PLAN 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) WELD SYMBOL OR REFERENCE (MAY BE OMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE G.. TRAP SEAL PRIMER VALVE MA" AUTOMATIC AIR VENT (WITH DRAIN) FILLET WELD BACKFLOW PREVENTER UNCLASSIFIED VALVE BFP 4 BALANCE VALVE WITH METERING PORTS Qv mo-- BALANCE VALVE W/0 METERING PORTS -141-/-1f 1- BALL VALVE, OPEN / CLOSED VACUUM CLEANING OUTLET BUTTERFLY VALVE . VALVE BOX COOLING COIL CHILLED WATER -1.=:C 1 row! WYE STRAINER (WITH DRAIN VALVE) FLOAT VALVE 1>Q1 FLOWMETER, VENTURI TYPE -- FLOWMETER ORIFICE - /-►♦ ISOLATION VALVE, OPEN / CLOSE _IA_ GATE VALVE, OUTSIDE SCREW AND YOKE —Dmil GATE VALVE, WITH HOSE CONNECTION -1:01-/-tal-GLOBE VALVE, OPEN / CLOSED HEATING COIL Com! / $ LIFT CHECK VALVE -MAV MANUAL AIR VENT (WITH DRAIN) A MOTOR OPERATED VALVE NEEDLE VALVE A NITROGEN DROP ON NITROGEN OUTLET —I*— PETCOCK t -H41{ PETE'S PLUG, WITH BALL VALVE wi- PLUG VALVE/STOP COCK 410 PRESSURE GAUGE WITH VALVE PRESSURE REGULATING VALVE W/EXT PRESS TAP. 1 PRESSURE REGULATING VALVE (SELF CONTAINED) ii -' PRESSURE RELIEF VALVE / SAFETY VALVE -Dzi QUICK OPENING VALVE QUICK CLOSING VALVE, FUSIBLE LINK -A4 A SOLENOID OPERATED VALVE STEAM TRAP ii — SWING CHECK VALVE WITH FLOW A GAS PRESSURE REGULATOR PIPING SPECIALTIES SYMBOL DESCRIPTION DESCRIPTION TEST PLUG OPENING OF PLUG WELDS OR 77/1; 21 THERMOMETER, LINE MOUNT CONTOUR SYMBOL FINISH SYMBOL 1 �1 THERMOMETER, SEPARABLE WELL MOUNT GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL CONNECTING REFERENCE LINE TO ARROW SIDE ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS f-1 R S E{ o o N} L- T 3tOR �� 8%(7) CN) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED TRAP, FLOAT WELD SYMBOL OR REFERENCE (MAY BE OMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE G.. TRAP SEAL PRIMER VALVE TP FILLET WELD UNCLASSIFIED VALVE V -I A VACUUM DROP (LAB VAC) Qv VACUUM OUTLET (LAB VAC) HARD PIPED v SPOT OR PROJECTION WELD VACUUM CLEANING OUTLET O VALVE BOX VALVE IN RISER (TYPE SPECIFIED) -1.=:C 1 WATER HAMMER ARRESTOR WYE STRAINER (WITH DRAIN VALVE) ' REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION WELDING SYMBOL DESCRIPTION ROOT DEPTH FOR SLOT EFFECTIVE THROAT SIZE STRENGTH CERTAIN OPENING OF PLUG WELDS OR 77/1; FILLING AND FOR WELDS TARROW CONTOUR SYMBOL FINISH SYMBOL 1 P GROOVE ANGLE, INCLUDED ANGLE OF COUNTERSINK FOR PLUGWELD LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL CONNECTING REFERENCE LINE TO ARROW SIDE ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE LINE NUMBER OF SPOT OR PROJECTION WELDS f-1 R S E{ o o N} L- BASIC DETAIL TAIL REFERENCE SPECIFICATIONS, OR 3tOR �� 8%(7) CN) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED WELD SYMBOL OR REFERENCE (MAY BE OMITTED WHEN IS NOT USED PROCESS OTHER REFERENCE G.. BACK WELD L FILLET WELD PLUG OR SLOT WELD • 11 SQUARE WELD O SPOT OR PROJECTION WELD x(,13—U33 ISSUED FOR CONSTRUCTION APRIL 12, 2013 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER Wood Harbinger 3009 urth Ave NE, Suite too Bellevue WA 98004 425.628.6000 - woodharbinger.com SYM REVISION BY APPROVED DATE SYM REVISION APPROVED DATE DC FREEZER ADDITION J# 16262 WH GV 04.12.13 ep1O7dV"' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT4 DATE DRAWN G. VERSEGI DATE 04.12.13 CHECKED E. LARSON 04.12.13 SUBTITLE ENCINEER G. VERSEGI CHECKED E. LARSON APPROVED APPROVED 04.12.13 04.12.13 TITLE PIPING LEGEND DC FREEZER ADDITION CURRENT REVISION J# 16262 SYMBOL DATE 04.12.13 BUILDING 9-101 MFCHANICAI MASTER 1.0 SHEET M1A JOB NO. 16262 COMP NO. DWG NO. A-1 n1-M1A KHON: 02/13 AA./5 3"SAN UP TO FD -A .5 DELETED FINISHED FLOOR ELEVATION IS 15'-6" - 3"SANinkc, ov\ Sefr &V\ SEGMENTED FLEXIBLE LEAK PROOF SLEEVE 4"OW FOR CONTINUATION SEE CIVIL DRAWING C302 Oil/Water Separator is under separate permit w cn w w 0 0 U 0 LL 3"SAN UP TO FD -A 2"V UP .r, FCO — 4"V UP 6"SAN UP TO 8" STANDPIPE, FOR. DETAIL SEE UGM148 M607 6"SAN 8"F, SEE CIVIL F CONTINUATION 22.5 6"SAN FOR CONT SEE CIVIL DRAWING C IE 11.67' 302 8# Fire pipe is under separate permit LEGEND SAN SANITARY SEWER OW OILY WASTE V VENT IE INVERT ELEVATION GENERAL NOTES 1. FOR LEGEND AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1A. 2. FOR SANITARY SEWER RISER DIAGRAM, SEE SHEETS AND M607 UGM148 M607 CONSTRUCTION NOTES TT( UGM110 UGM111 COORDINATE LOCATION OF THE FLOOR DRAIN WITH THE UNDERFLOOR HEATING SYSTEM MANIFOLD ASSEMBLY. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION UGM112 UGM113 UGM114 UGM115 UGM116 UGM117 UGM118 UGM119 UGM120 UGM121 UGM122 UGM123 UGM124 UGM125 UGM126 UGM127 UGM128 1>W-.033 UGM129 UGM134 UGM130 UGM135 UGM131 UGM136 UGM132 UGM137 UGM133 UGM138 UGM139 UGM140 UGM141 UGM142 UGM143 UGM144 UGM145 UGM146 UGM148 9-101.1 KEY PLAN RECEIVED SCALE: N.T.S. CITY OF TUKWII.. A MAY 232013 PERMIT CENTER ISSUED FOR CONSTRUCTION APRIL 12, 2013 8 4 0 4 8 16 SCALE: 1/8" = 1'-0" �Wood Harbinur wog iizth Ave NE, Suite too Bellevue WA 98004 425.628.6000 - woodharbinger.com REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DC FREEZER ADDITION J# 16262 WH GV 04.12.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN G.VERSEGI DATE 04.12.13 CHECKED SUBTITLE PARTIAL UNDERGROUND PLUMBING PLAN CURRENT REVISION J# 16262 SYMBOL DATE 04.12.13 APPROVED BY DEPT. DATE ENGINEER G.VERSEGI CHECKED 04.12.13 APPROVED APPROVED TITLE MECHANICAL MASTER DC FREEZER ADDITION BUILDING 9-101.1 COL. W -Z/21-22 D.0 SHEET UGM148 JOB NO. DWG NO. 16262 9-101.1-UGM148 COMP NO. 3 2:58:35 PM N W (-) SEE SHEET 1M42 FOR CONTINUATION -T I_..._.... w. FOR CONTINUATION SEE SHEET 1M38 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION UTILITY HATCH FOR 1" AIR OUTLET IN TRENCH, SEE 9\ 1M1,1 M605 UTILITY HATCH FOR 1" AIR OUTLET IN TRENCH, SEE / g 1M143 M605 0 • UTILITY HATCH UTILITY HATCH (TYP) 1M143 TNM 502 FOR CONTINUATION SEE SHEET 1M46 4"A, 4"VAC I & 6"VAC II DOWN TO THE TRENCH, FOR CONT. SEE DWG. TNM 143 & DWG. C ► M147 FOR TRUSS LOCATION 4"A TO MFC, SEE M553 1"A WITH L E 1"CW DN, PROVIDE 1" BALL VALVE 48" AFF SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RELOCATED CA, VAC I&II TO DWG. CWM147 S.RUDELL 02.12.08 RELOCATE SEALAUNCH 11670978 M.WONG RWS 03.29.11 B UTILITY RELOCATION FOR DC FREEZER - IFC WH GV 11.08.12 C DC FREEZER ADDITION J#16262 WH GV 02.13.13 rITv rnPP CTInM I FTITP 19 .I$1 R7R9 WH (,V n4:n1.1 3 BOE/NG' rr- ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M.WONG FOR CONTINUATION DATE 11.13.07 .5 LEGE A VAC CW COMPRESSED AIR PROCESS VACUUM COLD WATER GENEAL \OTES COMPRESSED AIR AND PROCESS VACUUM PIPING SYSTEMS: INSTALLATION OF COMPRESSED AIR AND PROCESS VACUUM PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH FACILITIES MECHANICAL STANDARD D38106-20 USING THE FOLLOWING DEVELOPMENTAL CENTER SITE—SPECIFIC PREFERENCES: PIPE: ASTM B-88 SEAMLESS COPPER, TYPE L, HARD DRAWN. FITTINGS: 2" AND SMALLER: WROUGHT OR CAST COPPER SOLDERED OR PROPRESS SOCKET FITTINGS. BRAZED JOINTS BELOW GROUND. 2-1/2" OR LARGER: TYPE L COPPER ROLL—GROOVED FITTINGS AND DUCTILE IRON ROLL—GROOVED COUPLINGS WITH EPDM GASKETS, RIGID SYSTEM. VALVES: 2" AND SMALLER: BRONZE TWO—PIECE BALL VALVE, THREADED END. APOLLO 70-100. PROVIDE WITH THREADED ADAPTER FITTINGS. 2-1/2" AND LARGER: ELASTOMER—LINED LUGGED BUTTERFLY VALVE. FURNISH WITH 125# COPPER FLANGE ADAPTERS. DEMCO 211xx TESTING OF NEW COMPRESSED AIR AND PROCESS VACUUM PIPING SHALL USE COMPRESSED AIR OR NITROGEN AT 150 PSIG FOR 1 HOUR. THERE SHALL BE NO LOSS IN PRESSURE. CHECK EACH JOINT WITH SOAPY WATER. 3. FOR LEGEND AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1A. EFEH\ CE DAWI\GS 9-101-CWM147 9-101-TNM143 EAST ANNEX CATWALK PLUMBING PLAN PLUMBING TUNNEL #14 PLAN CO\STRUCTIO\ \ ETES CONNECT 1 "CW TO EXISTING DOMESTIC COLD WATER PIPE LOCATED IN PROXIMITY OF Z21 COLUMN. A ,E CONNECT TO EXISTING 4"VAC RISER LOCATED AT COLUMN Z21. 1M110 1M116 1M122 1M128 ?(,r 033 1M111 1M117 1M123 1M134 1M129 1M139 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER PERMIT SET APRIL 1 201 1M112 1M113 1M114 1M115 0 1M118 1M119 1M120 1M121 1M124 1M125 1M126 1M127 1M130 1M135 1M140 1M131 1M136 1M141 114144 1M132 1M137 1M142 1M145 1M133 1M138 1M146 1M148 9-101.1 KEY PLAN SCALE: N.T.S. 8 4 0 8 16 SCALE: 1/8" = 1 '-0" wood Harbinger 3o€)9 :xxxlh: Ave NE, % xou Bellevue WA 9ll CHECKED SUBTITLE 1ST FLOOR PLUMBING PLAN CURRENT REVISION J#16262 SYMBOL D DATE 04.01.13 1 '•FR•r17 DAA APPROVED BY DEPT. DATE ENGINEER M.WONG 11.13.07 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER DC FREEZER ADDITION BUILDING 9-101.1 COL. W-7 /21-22 SHEET 1M143 JOB NO. J546111-00 COMP NO. DWG NO. I�_C_ g -101.1-1M143 !'DFrl!• A /1 /'(1 FOR CONTINUATION SEE SHEET 1 M45 TRENCH BELOW (TYPICAL) FOR CONTINUATION SEE SHEET 1M43 UTILITY . HATCH UTILITY I- F ATCH (TYP) 1M146 XXXX ATCH ATCH FIST FLOO SCALE: 1/8"=1 —0" DLA A vjv / VAC VAC UTILITY HATCH TRENCH BELOW (TYPICAL) UTILITY HATCH UTILITY HATCH UTILITY HATCH SEE DWG 1M143 FOR CONTINUATION 2 2"VAC DN, FOR CONT SEE 1M148 1"A DN, FOR CONT SEE 1M148 If 1 C 6 2"VA 2"A 1"CW UP, FOR CONT SEE RFM148 UI 2"VAC—�„ 2"A DUPLEX VACUUM DROP 1M146 M534 - 21/AC C.0 rlo REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ADD POWER, AIR Sc VACUUM J#546111-00 C. HARRAH RWS 06.13.04 F REDLINES CD01 11047.006 NC WH LEG 04.04.12 ADD UTILITIES AND LIGHTS J#546775-00 M.WONG RWS 12.06.04 G UTILITY RELOCATION FOR DC FREEZER - IFC WH GV 11.08.12 RELOCATE SEALAUNCH 11670978 M.WONG RWS 03.29.11 H DC FREEZER ADDITION J# 16262 WH GV 02.13.13 RELOCATE DEV—TEST — 90% SUBMITTAL WH_11047.006 WH JDM 06.14.11 CITY CORRECTION LETTER #2 J#16262 WH GV 04.01.13 DCI (IrsATC TIC /_TCCT _ IC!` WI -I 1 1 M7 nnF W-1 nA 11 giBOE/A/G'- ACCEPTABILITY THS DESIGN AND/OR SPECIFICATION IS APPROVED REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION DUPLEX AIR DROP OUTLET 6 DRAWN C. HARRAH (TYP) 1M146 M534 DATE 6.9.04 'EFRE \CE ��AWI \GS 9-101—TNM146 TUNNEL PARTIAL PIPING/PLUMBING PLAN 9-101 —1 M396 DUST COLLECTION FIRST FLOOR PLAN X6 13' 033 LEGE\D A VAC CO GE\ COMPREESED AIR PROCESS VACUUM DUPLEX PROCESS VACUUM OUTLET DUPLEX COMPRESSED AIR OUTLET EAL NOTES FOR HOUSE KEEPING VAC. & DUST COLLECTION SEE FIRST FLOOR PLAN, 9-101-1M396 1. FOR HOUSE KEEPING VAC. & DUST COLLECTION SEE FIRST FLOOR PLAN, 9-101-1M396 2. COMPRESSED AIR AND PROCESS VACUUM PIPING SYSTEMS: INSTALLATION OF COMPRESSED AIR AND PROCESS VACUUM PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH FACILITIES MECHANICAL STANDARD D38106-20 USING THE FOLLOWING DEVELOPMENTAL CENTER SITE—SPECIFIC PREFERENCES: PIPE: ASTM B-88 SEAMLESS COPPER, TYPE L, HARD DRAWN. FITTINGS: 2" AND SMALLER: WROUGHT OR CAST COPPER SOLDERED OR PROPRESS SOCKET FITTINGS. BRAZED JOINTS BELOW GROUND. 2-1/2" OR LARGER: TYPE L COPPER ROLL—GROOVED FITTINGS AND DUCTILE IRON ROLL—GROOVED COUPLINGS WITH EPDM GASKETS, RIGID SYSTEM. VALVES: 2" AND SMALLER: BRONZE TWO—PIECE BALL VALVE, THREADED END. APOLLO 70-100. PROVIDE WITH THREADED ADAPTER FITTINGS. 2-1/2" AND LARGER: ELASTOMER—LINED LUGGED BUTTERFLY VALVE. FURNISH WITH 125# COPPER FLANGE ADAPTERS. DEMCO 211xx 3. TESTING OF NEW COMPRESSED AIR AND PROCESS VACUUM PIPING SHALL USE COMPRESSED AIR OR NITROGEN AT 150 PSIG FOR 1 HOUR. THERE SHALL BE NO LOSS IN PRESSURE. CHECK EACH JOINT WITH SOAPY WATER. FOR LEGEND AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1A. CO\ST JCTIO\ \OTES POINT OF CONNECTION TO EXISTING COMPRESSED .. P PROVIDE DOMESTIC COLD WATER, AIR AND VACUUM PIPES. PROVIDE SEISMIC LOOPS. 0 0 0 0 OMPRESSED 1M10 1M11 1M12 1M13 1M14 1M15 1M16 1M17 1M18 1M19 1M20 1M21 1M22 1M23 1 M24 1M25 1 M26 1M27 0 0 11 1M 28 1M29 —11M34 1 M39 1M30 1 M35 1 M40 1M31 1 M36 1M 41 1M32 1 M37 1 M42 1M 33 1M38 1 M43 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER PERMIT SET APRIL 1, 2013 1M44 1 M45 /M46////// 1 M 48 9-101.1 SCALE: N.T.S. 8 4 KEY PLAN 0 4 8 SCALE: 1/8" = 1'-0" 16 Wood Harbinger 3009 u2th Ave NE, Suite ioo Bellevue WA 98004 425.628.6000 woodharbinger.com CHECKED SUBTITLE 1ST FLOOR PIPING PLAN CURRENT REVISION SYMBOL J# 16262 DATE 04.01.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE DC FREEZER ADDITION BUILDING 9-191.1 MFrIANIC.A1 MASTFR 1'.(11 W-7 /99-7.-i nr. SHEET 1M146 JOB NO. J#546111 COMP NO. DWG NO. A-1(11-1KA14F rvrru• A /1 /91111 9.c7•10 VACUUM PRV STATION FOR DETAIL, SEE 1M148 M607 2"VAC UP, FOR CONTINUATION SEE 1 M146 1"A UP, FOR CONTINUATION SEE 1M146 FOR CONTINUTATION SEE SHEET 1M143 { 1 : r2 EVAPORATOR, TYP 2"CO 1"CD FOR CONTINUATION SEE SHEET 1M147 F 1"CD 2"CD 1"CD 1"CD_\ 1"CD 1"CD 2"C D77\ /-1 ""C D 1"CD EYE WN5H 3A1T::RY GI1,$d"t( R BAIrERY CHARGER 1-1/2"CD FOR [- CONTINUATION SEE 1M146 Liu 2"VAC TO VACUUM ASSISTED LIFT 2"CD X X AIR I..... IA EA 1 2A 21 AL THAW • I\l.. i1'v{ �rJ. M • 1 3Y22 _ET RACK PALLET RACK 0 123 OD >13Vi I.311Vd V .x,11 { IC) EI...ECT R GAL. ZOOM 13A 221 4,1 2"CD C` 0,, CONT SEE RFM148 -ELECTRONIC TRAP PRIMER FOR J 7.0 t.7.7=7:=11, : Co, CA 8" STANDPIPE, FOR DETAIL SEE t•� MECHANICAL 1 M148 M607 [1 `JV\2t.-.... �A,�t.!. . -74 C) PLA\ SCALE: 1/8" = 1'- .r s. € {-µ • REVIEWED +FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION o LEGE I J A COMPRESSED AIR VAC PROCESS VACUUM CD CONDENSATE DRAIN DUPLEX COMPRESS/VACUUM DROP GE\PAL \OTES 1. FOR LEGEND AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1A. 2. HEAT TRACE CONDENSATE DRAIN PIPES. 3. FOR WALL MOUNTED VACUUM QD OUTLETS, SEE ( 6� 1M14 I\.1607 4. FOR WALL MOUNTED COMPRESSED AIR QD OUTLETS, SEE 1M148 M607 5. MAINTAIN ALL CONDENSATE DRAIN PIPING AT MAXIMUM POSSIBLE ELEVATION. BOTTOM OF CONDENSATE PIPE INSULATION SHALL NOT BE BELOW 26' ABOVE THE FINISHED FLOOR. C FOR SANITARY SEWER RISER DIAGRAM, SEE SHEETS (a-) AND I 1 1M148 M 607 1M148 M607 \ST UCTIO\ \OTES PROVIDE P -TRAP ON THE CONDENSATE DRAIN PIPING. PROVIDE SEISMIC LOOP SIZED TO PROVIDE MINIMUM 3" MOVEMENT IN ALL DIRECTIONS. FOR CONDENSATE DRAIN SEISMIC LOOP DETAIL, SEE 1M148 M607 ?- ,V T T T T 0 1 14110 1M111 1M112 1M113 1M114 1M115 1M116 1M117 1M118 1M119 1M120 1M121 1M122 1M123 1M124 1M125 1M126 1M127 I 1M128 1M129 1M130 1M131 1M132 1M133 1M134 1M135 1M136 1M137 1M138 1M139 1M140 1M141 1M142 1M143 r148� j// 114144 1M145 1M146 RECEIVED CITY OF TUKWILA MAY 232013 PERMIT CENTER ISSUED FOR CONSTRUCTION APRIL 12, 2013 9-101.1 KEY PLAN SCALE: N.T.S. 8 4 0 8 16 SCALE: 1/8" = 1'-0" Wood ili Hdrbiner 3009 urth Ave NE, Suite 100 Bellevue WA 98004 425.628.6000 woodharbinger.com SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DC FREEZER ADDITION J# 16262 WH GV 04.12.13 BOE/NG` ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN G. VERSEGI DATE 04.12.13 CHECKED E. LARSON 04.12.13 SUBTITLE 1ST FLOOR PLUMBING PLAN CURRENT REVISION J# 16262 SYMBOL DATE 04.12.13 APPROVED BY DEPT. DATE ENGINEER G. VERSEGI 04.12.13 CHECKED E. LARSON 04.12.13 APPROVED APPROVED TITLE DC FREEZER ADDITION BUILDING 9-101.1 MFCHANICAI MASTFR no' W-7/21-77 SHEET 1M148 JOB NO. J# 16262 COMP NO. DWG NO. nr. q-11.1-1M14R CPECK: 4/1/2013 2:52:13 PM FOR CONTINUTATION SEE SHEET RFM143 j}1 rr l.. -... Fl 1"CW DN, FOR CONT, SEE 1M146 SEISMIC LOOP, MINIMUM 12" OF MOVEMENT IN ALL DIRECTIONS FOR CONTINUATION SEE SHEET RFM147 FOR CONTINUTATION SEE SHEET L 1"CW DN, FOR CONT, SEE 1M148 4"VTR SEISMIC LOOP, MINIMUM 3" OF MOVEMENT IN ALL DIRECTIONS, SEE RFM148 607 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION 4, LEGEND CW COLD WATER GENERAL NOTES 1. FOR LEGEND AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1A. 2. HEAT TRACE CW PIPES. 3. FOR SANITARY SEWER RISER DIAGRAM, SEE DETAILS 8 AND RFM148 M607 RFM148IM607 CONSTRUCTIO\ \OTES 1 )"( RFM110 ROUTE 1 "CW PIPE ADJACENT TO ELECTRICAL CONDUITS. RFM111 RFM112 RFM113 RFM114 RFM115 RFM116 RFM117 RFM118 RFM119 RFM120 RFM121 RFM122 RFM123 RFM124 RFM128 RFM126 RFM127 RFM128 G(3O33 RFM129 RFM13 RFM130 4 RFM135 RFM139 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER ISSUED FOR CONSTRUCTION APRIL 12, 2013 RFM140 RFM13' RFM136 RFM14' RFM144 RFM132 RFM137 RFM142 RFM145 RFM133 RFM138 RFM143 RFM146 9-101.1 KEY PLAN SCALE: N.T.S. 8 4 0 4 8 16 SCALE: 1/8" = 1'-0" Wood Ail Harbinger 3009 n2th Ave NE, Suite 100 Bellevue WA 98004 425.628.6000 - woodharbinger.com REVISION BY APPROVED DATE SYM REVISION APPROVED DATE DC FREEZER ADDITION J# 16262 WH GV 04.12.13 rzs,ifv�' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED D N G. VERSEGI DAT 04.12.13 CHECKED E. LARSON 04.12.13 SUBTITLE APPROVED BY DEPT. DATE ENGINEER G. VERSEGI 04.12.13 CHECKED E. LARSON 04.12.13 APPROVED APPROVED TITLE MECHANICAL MASTER ROOF PLUMBING PLAN DC FREEZER ADDITION BUILDING 9-101.1 COL. W -Z /21-22 CURRENT REVISION J# 16262 SYMBOL DATE 04.12.13 D.C. 5N� RFM148 JOB NO. J# 16262 COMP NO. DWG NO. 9-101.1—RFM148 KHON: 02/13/13 14:45 RIGIDLY ATTACHED PIPE TO THE FREEZER BUILDING STRUCTURE ti PROVIDE OVERSIZED HOLE IN THE WALL WITH 3" CLEARANCE ALL AROUND THE PIPE THE DETAIL APPLIES TO FIRE SPRINKLER AND COLD WATER PIPES. PIPE SEIS PLA\ VIEW V11C LOOP DETAIL SEISMIC LOOP SCALE: NONE GALVANIZED WIRE MESH BASKET 1/2"x1/2" OPENIN 1/2" TRAP > TP > PRIMER 4 4 6" 24" 4 . DRAIN FROM FIRE SPRINKLER SYSTEMS AND EVAPORATOR CONDENSATE DRAINS PROVIDE STANDPIPE WITH SHEETMETAL SPLASH HOOD 1 " AIR GAP 8" STANDPIPE FLOOR RFM148, M616 M607 1 /2"VAC` FOR WALL ASSEMBLY DETAIL REFER TO ARCHITECTURAL DRAWINGS RIGIDLY ATTACHED PIPE TO THE FREEZER BUILDING STRUCTURE CONDENSATE DRAIN FROM EVAPORATOR (S) RIGIDLY ATTACHED PIPE TO THE THAW ROOM/MECHANICAL ROOM/AIR LOCK BUILDING STRUCTURE CONDENSATE DRAIN TO STAND PIPE SEISMIC LOOP PROVIDE OVERSIZED HOLE IN THE WALL WITH 3" CLEARANCE ALL AROUND THE PIPE CO\H\SATE PRE SEISv SCALE: NONE PIPE CLAMP (TYP) CHANNEL SUPPORT MOUNTED ON WALL (TYP) 1/2" ADAPTER, FEMALE SOLDER SOCKET x MNPT 1/2" BALL VALVE, APOLLO, 70-100 1/2" BLK STL NIPPLE 1/2 BLK MI TEE 1/2"x3/8" BUSHING (TYP) 3/8" 90° STREET ELBOW BLK MI (TYP) 3/8" PROCESS VACUUM QD COUPLING SWAGELOK MODEL SS-QC6-D-6PM (TYP) 8"x6" REDUCER 3"V Q 6"SAN 6" P -TRA DETAIL SCALE: NONE (5� UGM148, 1M1481M607 FINISHED FLOOR 3 FLEX VAC, UV SCALE: NONE 3 IC LCOP DETAIL(2� Oil/Water Separator is submitted under separate permit 0D OUTLET DETAIL (-6- 1M148 M607 1M148 M607 1/2"A-- PIPE CLAMP (TYP) CHANNEL SUPPORT MOUNTED ON WALL (TYP) 1/2" ADAPTER, FEMALE SOLDER SOCKET x MNPT 1/2" BALL VALVE, APOLLO, 70-100 1/2" BLK STL NIPPLE 1/2" BLK MI TEE REDUCING BUSHING (TYP) 3/8" STREET ELBOW BLK MI (TYP) FINISHED FLOOR DUPLEX AR 3'OP PARKER EZ-371-8FP 3/8" MPT QUICK DISCONNECT COUPLING (TYP) OUTLET 3ETAIL SCALE: NONE t� l Trey � rivvn hec cci �NtC�S G9hC�UnCa� Wash is GQI\ktNADus. 4fSL %31 1 M1 ,t.E 1‘ 607 •3er A AG \D v VENT P PI \G SCALE: NTS (8 UGM148,1 M148,RFM148 M607 2"VAC 1/2" TO DUPLEX VACUUM OUTLET VAC L L, V VACUUM IN = 27 IN HG VACUUM OUT = 18 IN HG FLOOR Pkv STATIO\ SCALE: NONE (/-7) iM148 M607 SA\ITAY A\ �ISE� -IAGV\ 3 v LEGE\ 3 GE\HAL \OTES EFRE\CE \GS CC \ STR U CTI O \ \OTES REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION V&flO33 6" VE\T PIP \G SAN 6"SAN, SEE CIVIL DWG C302 FOR CONTINUATION 9 SCALE: NTS UGM 148,1 M 148,RFM 148 •M607 ISSUED FOR CONSTRUCTION APRIL 12, 2013 RECEIVED CITY OF TUKWILA MAY 2 3 2013 PERMIT CENTER �Wood Harbiner 3009 oath Ave NE, Suite io0 Bellevue WA 98004 425.628.600o woodharbinger.com e=SYM — REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DC FREEZER ADDITION J#16262 WH GV 04.12.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN C. PECK DATE 04.12.13 CHECKED G. VERSEGI 04.12.13 SUBTITLE PLUMBING DETAILS AND SECTIONS CURRENT REVISION J# 16262 SYMBOL DATE 04.12.13 APPROVED BY DEPT. DATE ENGINEER G. VERSEGI CHECKED C. LARSON 04.12.13 04.12.13 APPROVED APPROVED TITLE MECHANICAL MASTER DC FREEZER ADDITION BUILDING 9-101.1 D.0 SHEET M607 JOB NO. J# 16262 COMP NO. DWG NO. 9-101.1-M607 KHON: 02/13/13