Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG13-047 - SUBWAY - ALTERATION
SUBWAY 305 TUKWILA PY PG1 3-047 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 0223000010 Address: 305 TUKWILA PY TUKW Project Name: SUBWAY PLUMBING/GAS PIPING PERMIT Permit Number: PG13-047 Issue Date: 05/01/2013 Permit Expires On: 10/28/2013 Owner: Name: BETA HOLDINGS LTD Address: 18827 BOTHELL WAY NE , BOTHELL WA 98011 Contact Person: Name: PATTY CASILLAS Address: PO BOX 732083 , PUYALLUP WA 98373 Email: Contractor: Name: PINNACLE PLUMBING INC Address: PO BOX 732083 , PUYALLUP WA 98373 Contractor License No: PINNAPI938MJ Phone: 253 691-2101 Phone: 253-820-4146 Expiration Date: 07/11/2013 DESCRIPTION OF WORK: PLUMBING FOR A RESTAURANT IN AN EXISTING TENANT SPACE Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $5,000.00 $326.81 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Date: Print Name: 4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J--. 1 inn 41411 On9 11A7 Drin+ ,1• A fll • • PERMIT CONDITIONS Permit No. PG 13-047 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4110 PG 13-047 Printed: 05-01-2013 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA. gov Plumbing/Gas. Permit No. Project No: Date Application Accepted: Date ;Application Expires (Fo, office use only)" PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3 Tenant Name: King o Assessor's Tax No.: 022 b/ Ob 1 _.PROPERTY OWNER : •(.....: Name:A�,�^^ ^ I (: p 1 ./. %��. „1 al C� w - , Ce 1 �/T A I th Address: I D 3 O ) t ia & VV av NYE 6 City.At/l 1 , State: /A zi1011 CONTACT PERSON - person receivingall, project communication Name: /.1—.y� f tv () I ma) eini h Address: 4 r ' j , _, Q (j City: L N W u 1 / ` State: 11► / ,{' Zip:Q, () V V t Phone: , . Email: / p 11i �l S ( 1.0(.n1q(l ' 41,V). ( U _ Ib Valuation of Project (contractor's bid price): $ ! 0 V 1 Suite Number: Floor: INIf ( New Tenant: 2 Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: 13o I I ) e .) Lt bi :Address: (p ft.)c---7.52t (f ppr Cit : State:\" Zi y �� a�� �.% V\% p�83�: Phone 47 5 4j Fax: Contr Reg No.:1>/. 1O A.JI-r /J 0 Ci7 (7,E�p Date: f j 1 /13 j .t Tukwila Business License No.: 71 Cis► 2-53 leaf. 2/ib p4 0j21tI Scope of Work (please provide detailed information): p/ubi A3 a. Silk itu eciAd in -ft on tcf bvi 1 i/r Building Use (per Int'l Building Code)• Occupancy (per Int'! Building Code): Utility Purveyor: Water: H:Upplications\Forms-Applications On Lme12011 Applicationa\Pluntbing Permit Application Rcviscd 8-9.11.docx Rcviscd: August 2011 blt Sewer Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain J 2 Shower, single head trap 2 - Sinks 24 1 Water heater and/or vent i Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) t Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) J 2 Lavatory 2 - Urinal L. Water heater and/or vent i Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller t Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial J 2 Wash fountain Water closet L. Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain J 2 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices 1 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). 1 HEREBY CERTIFY THAT T HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING �E OR AUTHORIZED AGENT: Signature: 73_i C 1 Print Name: `9I ( t 11,t " C45 ) 1 lets Date: 3 3/ / 1 Day Telephone:Z �3 Lill. -) 01 Mailing Address: 72tls p i� j% 1�� �%'( k 373 J City State Zip H:\Applications\Fornvs-Applications On Lint: \2011 Applications\Ptuntbing Permit Application Revised 8-9-1l docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223000010 Address: 305 TUKWILA PY TUKW Suite No: Applicant: SUBWAY RECEIPT Permit Number: PG13-047 Status: PENDING Applied Date: 04/02/2013 Issue Date: Receipt No.: R13-01194 Payment Amount: $326.81 Initials: JEM Payment Date: 04/02/2013 12:32 PM User ID: 1165 Balance: $0.00 Payee: PINNACLE PLUMBING INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4138 326.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 65.36 000.322.103.00.00 261.45 Total: $326.81 rinr• Rcrcin}-nR Printed: 04-02-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 r (206) 431-3670 Permit Inspection Request Line (206) 431-2451 P03-Og7 Project: SU 16 t)JALI Type of Inspection: *FII•IA ,- Pit Address: '3b TU >c Wit_ A PN Date Called: Special Instructions: Date Wanted:. a rrm_ n- I-7- I. C.m', Requester: Phone No: ..0(r,--7 30 - Scj sb7 JApproved per applicable codes. Corrections required prior to approval. COMMENTS: .1zzvvvk ;,u ( Inspecft ..3/AI4M / (14 1164-4-1 Date: I(EliSPECTION FEE REQ RED. Pryor to Vtd at 6300 Southcenter Suite 100. next inspection. fee must be Call to schedule reinspection. .4I INSPECTION RECORD Retain a copy with permit INSPECTION NO. I�Ca13,0"i 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit, Inspection Request Line (206) 431-2451 �. - Project:.Type -.-Li 6.—.) I) t-' of Inspection: %Rb? Imo—t3O2 1C.. Address: - 30 t 1.,;L3tLq P \ Datg -C�alled: `QC,LtC:,- a_ K.) tructions: Special Instructions: Date Wanted:. r� — 3 - \ " a- .m. p.m. Requester: Phone No: 0 E App oved.per applicable codes. COMMENTS: ElCorrections required prior to approval vr).k* - t42V --- ►gip P AJe 5U1 CPQ c16( e I >ti — 147,n ril J rr `-e:41 Inspector: lliQ� . A1LA/L(I,'l INSPECTIOt. FEE REQUIRE. Date 5 -) ? Prior to next inspection. fee must be id at 6300 Sauthcenter Blvd.. Suite 100. Call to schedule reinspection. To: City of Tukwila Public Works Department PROJECT: Subway 305 Tukwila Parkway Tukwila WA Permit No: D PG !3 -047 Date:3/20/2013 FriLE Copy 1. Subway will use : Schier GB -25 grease trap , see details & location on spec sheet s 2. Subway water line will be connect to an existing building water service. REVIEWED FOR CODE COMPLIANCE APPROVED- --- APR 3-C 2113 City o€ Tukwila BUILDING DIVISION 1'6 (-00147 CORREOTICN LTIS# S i t RECEIVED CITY OF TUKWILA MAR 12 2013 PERMIT CENTER RECEIVED CITY OF TUKWILA MAR 2 2 2013 PERMIT CENTER SPECIFICATIONS (GB -25) 1. 3" inlet/outlets Sch. 40. (No -Hub) 2. Max flow rate: 25 GPM 3. Liquid capacity: 22 Gallons 4. Max grease capacity: 75 lbs. (10.4 Gallons) 5. Max solids/sediment capacity: 2 Gallons 6. Unit weight w/std. covers: 31 lbs. 7. Standard covers handle 450 lbs. when unit is directly buried and a 2,500 lbs. load when buried in SR16 riser. 8. Maximum operating temperature 190'F continuous. OPTIONS ❑ Riser to grade ❑ Male pipe thread connections ❑ 2" inlet/outlet connection ❑ Clamping collar kit Signature of Approval: Company: Date of Approval: ipormk M•LA.N. !Mamba .0 .Oe. dowelled we* lamb q.ro PROPRIETARY AND col4iDer nut THE WON VAT= CONTAINED DI THU DRMNO 19 THE MOLE PROPERTY °RIc, RPRONOTM. ANY REPRODUCTION N PMT OR M A WHOLE WHTNOUT THE NRMEN PERLONON OF MCHER PMODUCTO B PRNMORE6 ieleGfide Riser Order Guide 0"-2" >2-1/8"-16" >16" t See order guide above to determine available dimension range 4-1/4" of plain end Inlet and outlet 10}3/4" OffiAGE112510iiti N/A WA Finished Grade TAG NUMBER: Outlet "B" (Standard) Static water line 9" invert PART NUMBER: GB -25 Engineered inlet and— diffuser SECTION "A A" TOP VIEW 21" END VIEW PERMIT CENTER SUBMITTAL SHEET DESCRIPTION: GREAT BASIN SERIES POLYETHYLENE GREASE INTERCEPTOR 25 GPM, 22 LIQUID GALLONS, 75 GREASE POUNDS CAPACITY DWG BY: TEU DATE: 10/17/11 REV: 1 -1/5/12 MATL: PE Schier Products 9500 Woodend Road Edwardsville, KS 66111 Tel: 800427-7119 Fax: 800-827-9664 www.schlerproducte.com Made In the U.SA SCHIER PRODUCTS Pioneering Drain line Purity SPECIFICATIONS (GB -25) 1. 3" inlet/outlets Sch. 40. (No -Hub) 2. Max flow rate: 25 GPM 3. Liquid capacity: 22 Gallons 4. Max grease capacity: 75 lbs. (10.4 Gallons) 5. Max solids/sediment capacity: 2 Gallons 6. Unit weight w/std. covers: 31 lbs. 7. Standard bolted, gasketed, gas/water tight composite covers handle 450 lbs. when unit is directly buried and a 2,500 lbs. load when buried in SR16 riser. 8. Maximum operating temperature 190"F continuous. NOTES 1. Listed by IAPMO to ASME grease interceptor standard #A112.14.3 2. Factory installed Built -In Flow control. 3. For gravity drainage applications only. Do not use for pressure applications. 4. 3/8" thick seamless high density polyethylene walls. 5. Riser is also available for burial. 6. Cover placement allows full access to tank for proper maintenance. 7. Vent not required unless per local code. 8. Engineered inlet and outlet diffusers are removable to InspecUclean piping. 9. For on -the -floor or buried applications. 10. Integral Air Relief / Anti -siphon. 11. Three outlet options for easy rough In. Unit shipped with outlet diffuser in outlet "B". DIFFUSION FLOW TECHNOLOGY i he inlet diffuser splits incoming effluent into two paths that utilize the entire liquid volume of the tank for efficient grease separation. The calibrated openings greatly reduce effluent turbulence. The effluent enters the main chamber without disturbing the existing grease or sediment layers. The integral air relief/anti-siphon in the top of the outlet diffuser allows pressure stabilization within the unit during operation. The bottom of the outlet diffuser allows only effluent which is free of grease to exit the tank. It can easily be attached to any of the three outlets provided to ease jobsite piping layouts. ENGINEER SPECIFICATION GUIDE Schier Great Basin^' grease interceptor model # shall be lifetime guaranteed and made in USA of seamss ei , rotationally - molded High Density Polyethylene with minimum 3/8' uniform wall thickness. Interceptor shag be furnished for above or below grade installation. Interceptor shall be bunt in accordance to ASME A112.14.3 (type C), with field adjustable riser system, built-in flow control, built-in test caps and three outlet options. Interceptor flow rate shall be GPM. Interceptor grease capacity shall be lbs. Cover shall provide water/gas-tight seal and have minimum 2,000 lbs load capacity. OPTIONS: i�egfide field adjustable risers for extending covers to grade • Male pipe thread connections • 2" Plain end pipe or male pipe thread connections • Clamping collar kit Iniumpba ai gads drawl Haug bulb IMMO PROPRIETARY AND CONNDEPTAL THE IN ORMmI OCMUeaO IN no ORRIMIO a re SOLE MOPE/IT/01 MIMI PRODUCTS. MY REPRODUCTORn PMT OR Al A MOW VITIHOUT ME~ EM PER1119630M0i =MR T00Y31e13 27" Outlet "A" (Optional) A A 21" Q of plain end inlet and outlet Outlet "C" (Optional) TOP VIEW 016" Cover --I 6-1/4" Static water line See Note #10 Outlet "B" (Standard) 15" 9" invert Engineered inlet and outlet diffuser (see discription) SECTION "A -A" PART NUMBER: GB -25 Deepstructural reinfrcing columns ISOMETRIC VIEW 21" 1 t END VIEW PERMIT CENTER SPECIFICATION SHEET DESCRIPTION: GREAT BASIN SERIES POLYETHYLENE GREASE INTERCEPTOR 25 GPM, 22 LIQUID GALLONS, 75 GREASE POUNDS CAPACITY DWG BY: TEU DATE: 10/17/11 REV: 0 MATL: PE Schier Products 9500 Woodend Road Edwardsville, KS 66111 Tel: 800-827-7119 Fax: 800-827-9664 www.schierproducts.com Made In the U.SA SCHIER PRODUCTS Pioneering Drain Line Purity April 22, 2013 Patty Casillas PO Box 732083 Puyallup, WA 98373 itio City of Tukwila Jim Haggerton, Mayor Department of COMMunity Development Jack Pace, Director RE: Correction Letter #1 Plumbing/Gas Piping Permit Application Number PG13-047 Subway — 305 Tukwila Py Dear Ms. Casillas, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, u\M e fer Ma hall lerrr�it �ec cian File No. PGI3-047 W:IPermit Center\Correction Letters120/3IPG13-047 Correction Letter #I.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: April 18, 2013 Project Name: Subway Permit #: PG13-047 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. One of the previous memo's requests was to: "Provide on the plan view all new drain waste and supply lines and indicate point of connections." The original architectural floor plan provided is what is expected to show the plan view indicating the plumbing DWV and supply lines layout. The revised plan is somewhat an isometric view however isometric views are typically drawn at a 30 degree angle. Also the revised plan was not clear where the design ran off the left side of the page; where some fixtures could not be identified. One fixture is indicated as a drain however not listed in the list of fixtures. Please clarify the drain; is it a floor drain or indirect floor drain for prep sink fixtures? Show where it is located on the architectural floor plan along with all other fixtures and clarify what fixtures shall drain in to it. Be specific about plumbing to fixtures and where all fixtures are located. (2009 UPC 103.2.3) 2. Show where cleanouts are located. (2009 UPC 707.0) 3. The grease trap (specified in the code as grease interceptor) was not originally indicated on the floor plan and schedule of fixtures. Show where the grease interceptor is located and include it in the schedule of fixtures. Provide manufacturers installation documents or manual and show the sizing of the grease interceptor is sized to facilitate the fixtures served and which fixtures shall drain into the grease interceptor. If the grease interceptor is located under sinks or tables, show it is sized to fit in its proposed location. This typically is done with an elevation view. The grease interceptor shall be located where it can easily be serviced and where drain waste has sufficient slope to the grease interceptor. Typically grease interceptors are vented at both sides of the unit. This also needs to be shown on the plan schematics. (2009 UPC 1014.0, 1014.2 & Table 10-2) Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. April 5, 2013 Patty Casillas PO Box 732083 Puyallup, WA 98373 /0 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Incomplete Letter #1 Plumbing/Gas Piping Permit Application Number PG13-047 Subway — 305 Tukwila Py Dear Ms. Casillas, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 2, 2013 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433-7163 if you have any questions regarding the attached comments. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431-3670. File No. PGI3-047 W:IPermit Center)Incomplete Letters120131PG13-047 Incomplete Letter #I.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: April 4, 2013 Project Nanic: Subway Permit #: PG13-047 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide on the plan view all new drain waste and supply lines and indicate point of connections. Identify sizes of each pipe. 2. Provide isometric drawings of each new plumbing system, also indicating points of connection and identify any other plumbing fixtures that share with the new plumbing system. Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. *EMIT COORD COPP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-047 DATE: 04/29/13 PROJECT NAME: SUBWAY SITE ADDRESS: 305 TUKWILA PY Original Plan Submittal _ Response to Correction Letter #_ Response to Incomplete Letter # _ Revision # after Permit lssued DEPARTMENTS: A -v Public Works L. 3Building Division Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ISr Incomplete ❑ DUE DATE: 04/30/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 05/28/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: GO PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-047 PROJECT NAME: SUBWAY SITE ADDRESS: 305 TUKWILA PY Original Plan Submittal Response to Correction Letter # DATE: 04-11-13 X Response to Incomplete Letter # 1 Revision # After Permit Issued TM` E TS: 4 144.9-15 Bu I Ing Divi 4.a Public Works Fire Prevention Structural Planning Division n n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04-16-13 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route ICJStructural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DUE DATE: 05-14-13 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2-28-02 Bldg i Fire 0 Ping 0 PW 0 Staff Initials: ADPERMiT COORD COP. PLAN REVIEW/ROUTING SLIP L. ACTIVITY NUMBER: PG13-047 DATE: 04/02/13 PROJECT NAME: SUBWAY SITE ADDRESS: 305 TUKWILA PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMEN S: & Ottc,3 Li! din (vision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete ❑ DUE DATE: 04/04/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: O t J,1 ? Departments determined incomplete: Bldg LETTER OF COMPLETENESS MAILED: Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route ❑ REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/02/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 410 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /71-2 —21 /_ Plan Check/Permit Number: O Response to Incomplete Letter # PResponse to Correction Letter # I ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: t 1 6 c.13c.t, Project Address: ga Contact Person: Ae:f- utl,-0Ln' Y ► •. 4 lir til P(1Phone Number: ogS �S;>? Q - v__\ Summary of Revision: i Ser,Q p\ovA, ) C�iv�el 4 -f -c4 - Am\ C; rec � Q. -C' Q 1(t .e__) f c\l trace) t- G 0,1.0 \A k1,e_ \Oci.aci1n9\0, vi S h APR 2 9 2013 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including -date of revision Received at the City of Tukwila Permit Ce ter by: )6 v-- " Entered in Permits Plus on Z 1 H:\Applications\Forms-Applications On Line \2010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 11 13 Plan Check/Permit Number: PG13-047 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Subway Project Address: 305 Tukwila Py Contact Person: Summary of Revision: C,45IIq 5 Phone Number: (z5;) c -GV -y l 4(j ovoTUKWILA APR 11113VV acRMIT Fns Sheet Number(s): "Cloud" or highlight all areas of revision including date of rgviion Received at the City of Tukwila Permit Center by: al—Entered in Permits Plus onLk-Al-6 C:\Users\jennifer-m\Desktop\Revision Submittal Form.doc Revised: May 2011 Contractors or Tradespeople Peter Friendly Page • Page 1 of 2 General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PINNACLE PLUMBING INC UBI No. 602719501 Phone 2538204146 Status Active Address Po Box 732083 License No. PINNAPI938MJ Suite/Apt. City Puyallup State WA Zip 983739998 County Pierce Business Type Corporation Parent Company License Type Construction Contractor Effective Date 7/11/2007 Expiration Date 7/11/2013 Suspend Date Specialty 1 Plumbing Specialty 2 Unused iated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PLUMBO*965DB PLUMBING OUTFIT, THE Construction Contractor Plumbing Insulation 3/2/2004 3/2/2008 Inactive ELKPL**942DB ELK PLUMBING Construction Contractor Plumbing Insulation 3/2/2006 3/2/2008 e- ic L Licensed Business Owner Information Name Role Effective Date Expiration Date CASILLAS, ARTURO JAVIER Director 07/07/2011 Bond Amount CASILLAS, PATRICIA TOMIKO President 07/11/2007 YLI246968 CASILLAS, ARTURO Vice President 07/11/2007 07/07/2011 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO YLI246968 07/09/2007 Until Cancelled Date Date $6,000.00 07/11/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information httns://fortress.wa. uov/lni/bbin/Print.asnx 05/01/2013 Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date 6 Hartford 01SBAAM4454 03/01/2012 03/01/2014 $1,000,000.0002/22/2013 Casualty Ins httns://fortress.wa. uov/lni/bbin/Print.asnx 05/01/2013 RECEIVED CITY OF TUKWILA APR 2 9 2013. PERMIT CENTER ti":"‘L 11'-1'16' X 4-5g. ,• �FLOOR AND WALL FINISH PLAN ) SCALE: 1/4" = 1' FORTH 4 4.01 L. 9" LegniiiiMinelIFIllr 0 MR 1 n N /a ELECTRIC AND DIMENSION PLAN �� SCALE: "/L" = 14," NORTH WALL FINISH LEGEND (TUSCANY II DECOR) *SEE TUSCANY II BACK -VP SHEET 1 OF 2 AND 2 OF 2 FOR PROPER INSTALLATION OF WALLFINISHES IN CUSTOMER AND SERVICE AREAS. (SEE TUSCANY SUPPIEMEN2AL TILE BACK --UP SHEEP WHEN APPLICABLE) FLOOR FINISH LEGEND- TUSCANY if DECOR (RANDOM PATTERN) TILE SYMBOL DESCRIPTION MAROFMW22R UPPLY DIEL: ROTES: ' NO. AREA OF STORE MANUFACTURER SUPPLIER TMST. SQ/FT DESCRIPTION QUENTIN WALLCOVERING SUNQO FMCS D.A.I. G.C. VINYL WALLCOVERING SUBWAY MURAL WALL COVERING 9JWLO FABRICS D.A.I. G.C. VINYL WALLCOVERING (WITH UPPER DECORATIVE TRIM MNG As REQUIRED) TUSCAN STUCCO WALLCOVERING RINGO FABRICS D.A.I. G.C. VINYL WALLCOVERING (WITH LOWER CHAIR RAL MOLDING AS REQUIRED) QUENTIN WALLCOVERING WINDOW FRAME TUSCAN STUCCO WALLCOVERING RED WALL COVERING SNNGD FABRICS D.A.I. SUMO FABRICS G.C. D.A.I. G.C. G.C. G.C. SUIK30 FABRICS D.A.I. G.C. VINYL WALLCOVERING PAINT SHERWIN WIWAMS #SW6356 COPPER MOUNTAIN. WITH CITYSCAPE MURAL & UPPER DECORATIVE TRIM MOLDING AS REQUIRED) VINYL WALLCOVERING (WITH LOWER CHAR RML MOLDING AS REQUIRED) VINYL WALLCOVERING CUSTOMER AREA CROSSVILLE G.C. G.c. 570 COLORBLOX STONE SERIES; 1r X 12' A1156 WHEAT COLCRBLOX STONE SERIES: 1r X 12- A1154 GREEN CQDRBLOX STONE SERIES; 1r X 1r A1153 CLAY WHEN INSTAWNG THE RANDOM PATTERN. THE PERCENTAGES OF THE ABOVE COLORS ARE AS FOLLOWS: WHEAT - 80%; GREEN - 121; CLAY.- SR (THE GREEN AND CLAY SHOULD BE DISTRIBUTED EVENLY. BUT RANDOMLY THROUGHOUT AS NOT TO REPRESENT A NOUCEABL PATTERN) USE DARK GREY OR DARK BROWN GROUT THROUGHOUT ENTIRE CUSTOMER AREA /F \ PDBfiC ACCESSIBLE RIETROOM CROSSVILLE GC. G.C. 80 COLORBLOX STONE SERIES: tr X 12' A1156 WHEAT WITH DARK GREY CR DARK BROWN GROUT. TUSCAN STUCCO WALLCOVERING 5512.0 FAFFE S D.A.I. G.C. VINYL WALLCOVERING (WITH LOWER CHAIR RAIL MOLDING) BUTIERNUT BRICK WALL COVERING SUM FARES D.A.I. G.C. VINYL WALLCOVERING • /F B • M AREA CROSSVILLE G.C. GC. ARMSTRONG G.C. G.C. 450 OPTION 11: COLORBLOX STONE SERIES; 1r X 1r A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. OPTION #2: 51830 COLOR: COTTAGE TAN 12- x 1r VINYL COMPOSITE TILE CONTINUED THROUGHOUT THE BACKROOM. Av CABINET/WALL LAMINATE MOSAIC TILE (RIGHT) WILSONART VACUFORM/ %%LSONART G.C. D.A.I. G.C. G.C. FONT -HILL PEAR (#10745-60) - INSTALL GRAIN HORIZONTALLY GRAPHIC IMAGES (SEE TUSCANY 11 BACK-UP SHEET FOR DETAILS AND OPTIONS) WITH WILSONART 110745-60 FONTHIL PEAR BORDER AND 4' UGHTED PURSE RAL. ACF. VIP MOSAIC TILE (LEFT) VACUFORM/ WILSONART D.A.I. G.C. GRAPHIC IMAGES (SEE TUSCANY N BACK-UP SHEET FOR DETAILS AND OPTIONS) WITH WILSONART /10745-60 FONTHILL PEAR BORDER AND 4' LIGHTED PURSE RAIL PAINTED WALL SHERWIN WILLIAMS G.C. G.C. PAINT (SHERWIN VAWAMS OFF -WRITE SEMI -GLOSS FINISH) ALA F.7 FIBERGLASS REINFORCED POLYESTER PANELS (FRP) MARUTE DAI/GC G.C. FRP PANELS - WATER RESISTANT COVERING. WHITE OR *ALMOND (*ALMOND OPTION ONLY IF PERMITTED BY HEALTH/BUILDING CODE) RESTROOM: TILED WALLS CROSSVILLE G.C. G.C. COLORBLOX STONE FLOOR TILE MOUNTED FLOOR TO CEIUNG. CHOOSE 1 OR MORE OF THE FOLLOWING A1153 CLAY. A1154 GREEN. A1156 WHEAT. NOTE: ALL WOOD INTERIOR DOORS, UPPER & LOWER MOLDING & CROWN MOLDING TO BE STAINED WITH MINWAX #235 CHERRY AND POLYURETHANED W/ MINWAX FAST DRYING CLEAR SATIN. NOTE: INSTALL F.R.P. VERTICALLY IN THE BACKROOM TO A MINIMUM HEIGHT OF 8'-0' ABOVE FINISHED FLOOR. TUSCANY II DECOR CALCULATIONS NOTE THE SUBWAY STORE DESIGN DEPARTMENT WILL NOT ACCEPT RESPONSIBIUTY FOR ANY INACCURACIES. THE CALCULATIONS PROVIDED BELOW MUST BE VERIFIED BY THE G.C. AND FRANCHISE OWNER BEFORE ANY ORDER FOR THESE MATERIALS IS ACCEPTED AND PLACED. QUANTITIES CALCULATION WORKSHEET CUSTOMER AREA 1) 36 YARDS CITYSCAPE MURAL 2) 40 YARDS OF TUSCAN STUCCO WALL COVERING I1'0 FEET OF UPPER DECORATIVE MOLDING 1<8 FEET OF LOWER CHAIR RAIL MOLDING 27 YARDS OF QUENTIN WALL COVERING (NON-1EDLAR) ABOVE CITYSCAPE MURAL AND SOFFIT.' 6) (- ) YARDS OF BUTTERNUT BRICK WALL COVERING ABO7) (-) OPEONACITYSCAPE L)FE HADWDWOODD CRAND OWN MOLDING (AT CORNER WHERE, WALL AND CEIUNG MEET) 8) (-) FEET. OF HARDWOOD CROWN MOLDING (FINISH CAP ON STRIP UGHTNG SHELF) 9) ( 3 ) YARDS Of RED WALL COVERING 10) ( - ) YARDS OF OMEN WMLE OWRWG (U11(1ELAR COATING) (FOR 48 HIGH BANQUETTE WALL ONLY) 1 2 3 4 5 6) 7) 8) 044/TS oR B/M/TS + s/M 0/1.4/1S OR B/M/TS + T/S Q/M/TS OR B/M/TS + S/M 0/AVIS OR B/M/TS + T/S (CEIUNG HEIGHT - 7'-61 X + 5% DIVIDED BY 12 (CEILING 6'X 5%IDEDBY 12 0/M/TS OR 8/M/TS + 5/11 + 1016 DIVIDED BY 3. + R/TS 10% DIVIDED BY 3 + 10% + R/TS 1016 (Q/M/T5 + SCM + (Q/WC CUSTOMER AREA & SOFFIT ONLY)) (B/M/Ts + s/M + (B/T IN CUSTOMER AREA & SOFFIT ONLY)) + R/TS (+ W/TS IF WINDOWS NOT TO CEIUNG) + IDX TOTAL LENGTH OF WALLS WHERE FLUORESCENT STRIP UGHTNG TO BE INSTATED + 1016 9) MGM 656*1 TOP OF TUSCAN STUCCO WALL COVERING TO CEDING (36- AFF.) x R/TS + SX DIVIDED BY 12 10) QT/WC + 109. DIVIDED BY 3. (CUSTOMER AREA ONLY) SERVICE AREA 11 11 - 4' X 12' SHEETS FONT --HILL PEAR LAMINATE* 12 - 12' T -MOLDING STRIPS • 13 33 YARDS CF BUTTERNUT BRICK WAIL. COVERING (WADS OIL 14 - YARDS CF 82618 TILL DAME (KIT OUR =DI (ILIUS OM, 15 1 RIGHT ( 1 )LEFT VEGETABLE MOSAIC OLE 16 ) (OPTIONAL) FEET OF COPPER CORNICE 1RUA 17 (- )) 4' X 12' SHEETS FONT -HILL PEAR LAMINATE (OPTIONAL FOR SOFFIT APPUCAIION) 11) FP/L + 5% DIVIDED BY 12 12) (FP/L ON 36' HIGH WALLS X 2) + (FP/L ON 48' HIGH WALLS X 3) + 5% DIVIDED BY 12 13 CEIUNG HEIGHT X B/T + 516 DIVIDED BY 12 14 CEILING HEIGHT X OT/WC + 5% DIVIDED BY 12 16) TOTAL LENGTH OF CUSTOMER SIDE OF HEADS RWAIL(S) OVER SERVICE AREA + 516. BACK ROOM 18) ( 17 ) MARUTE F.R.P. WHITE (ALMOND OPTIONAL IF PERMITTED BY HEALTH/DOWN CDOE) 19) 16 PVC DIVISION MOLDING 20) 5 PVC INSIDE CORNER 21) 1 PVC OUTSIDE CORNER 22) 6 PVC CAP MOLDING 18) W/ 1 + 5% DIVIDED BY 4 19) PANEL COUNT FROM #18 LESS 1 20) COUNT ALL INSIDE CORNERS WFERE W/R MEET 21) COUNT ALL OUTSIDE CORNERS WHERE W/R MEET 22) COUNT AL. EDGES WHERE W/R BEGINS & ENDS & DOORWAYS * CALCULATIONS ARE FOR FONT -HILL PEAR LAMINATE AND ALUMINUM T -MOLDING APPLIED TO 36' AND 48' HIGH WALLS. LAMINATE AND T -MOLDING. WHEN AFFIXED DIRECTLY TO DUKE FRONT COUNTER. IS SHIPPED READY TO INSTALL BY DUKE MANUFACTURING. NOTE THESE CALCULATIONS DO NOT INCLUDE THE MATERIALS NEEDED TO DECOR THE AREA ABOVE OR BELOW THE WINDOWS. *h- e item Fioor sin't WALL BASE NOTE•WALL BASE OPTION MUST MATCH FLOOR OPTION USTED ABOVE IN ALL AREAS OF STORE ALL AREAS SIINICB/HACLROOM AREA CROSSVIIlE ARMSTRONG G.C. GC. G.C. G.C. 6' X 12' COVE BASE OR 4' X 12' BULLNOSE: COLORBLOX STONE SERIES A1156 WHEAT WRH DARK GREY OR DARK BROWN GROUT. 6' BLACK VINYL COVE BASE. (USED WITH VINYL COMPOSITE FLOOR TAE ONLY) APHION COMMENTS. 1.) FLOORING CONTRACTOR IS RESPONSELE FOR OWN DE1ERMNATICNS ON SUBFLOOR REQUIREMENTS AND TO INSTALL IN ACCORDANCE VAIN CODE REQUIREMENTS AND TO INDUSTRY AND MANUFACTURER SPECIFICATIONS 2.) THE SQUARE FOOTAGE CALCULATIONS CF THE FLOGRNG MUST BE VERIFIED BY ME G.C. AND FRANCHISE OWNER SUBWAY STORE DESIGN DEPARTMENT WILL NOT ACCEPT RESPONSIBILITY FOR ANY INACCURACIES. 3.) BULLNOSE WALL BASE IS TO BE INSTAUED ON TOP OF THE TUSCAN STUCCO WALL COVERING, Y-3' OF TUSCAN STUCCO WALL COVERNG IS RECOMMENDED TO BE COVERED TO PROVIDE A TIGHT FIT. —2.500 Ib. Max. load 16" Max. 1 FLOOR TILE REY SUBMITTAL: PERMIT SUBMITTAL I COLOREILOX SERIFS: 12' X 12' A1154 GREEN COLORBLOX SERIES; 12' X 1r A1153 CLAY W '6 O N w o i RANDOM FLOOR TILE PLACEMENT EXAMPLE REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION ECEIVED CITY OF TUKWILA APR 2 9 2013 PERMIT CENTER GENERAL NOTES: NEW LOCATION SYMBOL LEGEND $ - 120V DUPLEX OUTLET iE - 22OV SINGLE OUTLET D - PHONE JACK 0 - JUNCTION BOX 0 - THERMOSTAT ®- ELECTRIC PANEL F.M.- FLOOR MOUNTED C.M. - CEILING MOUNTED 0 - FLOOR DRAIN E - FLOOR SINK - CEILING HEIGHT IS 6-10' - ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO 85 LOCATED IN CEILING ABOVE EACH WINDOW. - CURIO MODEL SW3-PLUS WATER FLTRATION SYSTEM IS REQUIRED N AU. NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALATICH IS MOUNTED TO SODA SYRUP RACK BY COCA-COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. MORD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE UMITATIONS OCCUR. REQUIRED 1/2' INCOMING WATER LINE FEED WITH 1/2' BALI. VALVE SHUTOFF AND 1/2' FPT CONNECTION. MINIMUM 110 VOLT. 20 AMP ELECTRICAL SERVICE TO SUPPORT TIE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). - SMARTCURVE STAN (MFR DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4' X 13 1/8' BASE. 56' (VA HOUT HEADER) OVERALL HEIGHT - SECONDARY CHP RAC( 15 REQUIRED IN THE CUSTOMER AREA. THE TWO AVAILABLE OPTIONS ARE BASKET STYLE CHP RACK AT THE PONT OF ORDER (PREFERRED RED PLACEMENT) OR PURSE RAL MOUNTED OAP RACK (MOUNTED ON TOP OF THE PURSE RAL) - EXIT UGHTS INSTALLED BY GC. PER LOCAL CODE - EMERGENCY 0014TS INSTALLED BY GC. PER LOCA. 030E.. - EXTINGUISHERS. SMOKE AND FIRE DETECTION SYSTOAS INSTALLED BY C.C. PER LOCAL CODE. - LABOR & MATERIAL SUPPUED BY G.C. UNLESS OTHERWISE NOTED. - AU. DIMENSIONS TO BE VERIFIED BY G.C. ON STE. - DECOR SPECIFICATIONS ARE TO BE SUBWAYS 'TUSCANY 11' SCHEME �G (3O'i � 0) E a) 0 0 E 4-0 .1.0 c a) c. _ foo. a)C as co 1 Q a) d RI 3 8 0 to (in coMi- A2.02 COLORBLOX SERIES; 12' X 1r A1156 WHEAT COLOREILOX SERIFS: 12' X 12' A1154 GREEN COLORBLOX SERIES; 12' X 1r A1153 CLAY RANDOM FLOOR TILE PLACEMENT EXAMPLE REVIEWED FOR CODE COMPLIANCE APPROVED APR 3 0 2013 City of Tukwila BUILDING DIVISION ECEIVED CITY OF TUKWILA APR 2 9 2013 PERMIT CENTER GENERAL NOTES: NEW LOCATION SYMBOL LEGEND $ - 120V DUPLEX OUTLET iE - 22OV SINGLE OUTLET D - PHONE JACK 0 - JUNCTION BOX 0 - THERMOSTAT ®- ELECTRIC PANEL F.M.- FLOOR MOUNTED C.M. - CEILING MOUNTED 0 - FLOOR DRAIN E - FLOOR SINK - CEILING HEIGHT IS 6-10' - ELECTRICAL OUTLET HEIGHTS MEASURED TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO 85 LOCATED IN CEILING ABOVE EACH WINDOW. - CURIO MODEL SW3-PLUS WATER FLTRATION SYSTEM IS REQUIRED N AU. NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALATICH IS MOUNTED TO SODA SYRUP RACK BY COCA-COLA. SECONDARY PLACEMENT OPTION IS MOUNTED ON THE BACKROOM WALL. MORD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE UMITATIONS OCCUR. REQUIRED 1/2' INCOMING WATER LINE FEED WITH 1/2' BALI. VALVE SHUTOFF AND 1/2' FPT CONNECTION. MINIMUM 110 VOLT. 20 AMP ELECTRICAL SERVICE TO SUPPORT TIE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). - SMARTCURVE STAN (MFR DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4' X 13 1/8' BASE. 56' (VA HOUT HEADER) OVERALL HEIGHT - SECONDARY CHP RAC( 15 REQUIRED IN THE CUSTOMER AREA. THE TWO AVAILABLE OPTIONS ARE BASKET STYLE CHP RACK AT THE PONT OF ORDER (PREFERRED RED PLACEMENT) OR PURSE RAL MOUNTED OAP RACK (MOUNTED ON TOP OF THE PURSE RAL) - EXIT UGHTS INSTALLED BY GC. PER LOCAL CODE - EMERGENCY 0014TS INSTALLED BY GC. PER LOCA. 030E.. - EXTINGUISHERS. SMOKE AND FIRE DETECTION SYSTOAS INSTALLED BY C.C. PER LOCAL CODE. - LABOR & MATERIAL SUPPUED BY G.C. UNLESS OTHERWISE NOTED. - AU. DIMENSIONS TO BE VERIFIED BY G.C. ON STE. - DECOR SPECIFICATIONS ARE TO BE SUBWAYS 'TUSCANY 11' SCHEME �G (3O'i � 0) E a) 0 0 E 4-0 .1.0 c a) c. _ foo. a)C as co 1 Q a) d RI 3 8 0 to (in coMi- A2.02 •irf . t. ,. � trtFd: rL 3r. RESTROOMS TO HAVE DRYWALL CEILINGS WMAIIIN•I } lliiR I ! S I °n I 2111 ?�11 , �, REIWIT 7 v i� M, AI Ifir' s IE Ciel.`} RSI t u tiJ`UI I *.i,F} t MITI'.•I'�.''�vr '�I�-'? �rsa�'fii� i<iz� CEILING &LIGHTING LEGEND 2' X 2' DROP CEILING WITH WHITE SPLINES. OPTIONAL PAINTED CEILING TILE AND SPLINE COLORS (SPLINES MUST BE PAINTED THE SAME COLOR AS TILES):: BLONDE PAINT (SHERWIN WILLIAMS #SW 6128) *CUSTOMER AREA ONLY* WHEAT GRASS PAINT (SHERWIN WILLIAMS #SW 6408) *CUSTOMER AREA ONLY* •YMBOL DESCRIPTION 2'X2' RECESSED. FLUORESCENT FIXTURE.. MANUF. SUPPLY' ORDERED PROM NOTES:. LIGHTOUER 2'X2' RECESSED FLUORESCENT UGHTOLIER FIXTURE:W/PARABOLIC; LENS. _ . • ACOUSTICAL DROP-IN SPECIALTY LIGHTING GROUP DAI 1 SPECIALTY LIGHTING GROUP RECESSED FLUORESCENT FIXTURE (SPS2GSVA2FT120SB). USES: (2) PL-L25W/835 2G11 LIGHT BULBS:' RECESSED FLUORESCENT FIXTURE \/PARABOLIC LENS (DPA2G9LS2FT120SB). USES (2) PL -125W/835 ;2G11 LIGH7 BULBS:. 2': X ' 2' DROP-IN PANEL SEPARATE PERMIT REOUIRED FOR: O Mechanical O Electrical O Plumbing Cl. Gas:Piping City of Tukwila DYLF7 —4 G DIVISION ACOUSTICAL DROP-IN •:. AS. G.0: Rum. 2' X 2' SURFACE MOUNTED. LIGHT FIXTURE WITH SEPARATE EXHAUST FAN LIGHTS, IT W/ 90 Iv11 I. ACKUP WAVE_MCOULAR SO TIT • 36" X52'X5"WI- H RECESSEC LIGHTING @ 8'-6" .F.F WAVE—MODULAR SOFFIT 36 X 52 X 5" .WITH ...:5 • 1fi RECESSED LIGHTING. �f @ 8'-6".A.F.F ILLUMINATED EXIT SIGN W/ BUG EYE EMERGENCY LIGHT IN/ 90 MIN BATTERY BACKUP POWER r.11I%•." f1G$4,r-1.1 EXTERIOR LIGHT W/ EMERGENCY 90 MIN. BATTERY BACKUP . • I"`'» HIGH SPEED DATA LINE & MODEM UNE REQUIRED EXISTING PERIMETER WALLS ===9 r-=- SPECIALTY LIGHTING GROUP ' . X 2' DROP-IN PANEL SUBMITTAL: STANDARD SURFACE MOUNTED. FIXTJRE WITH ENERGY SAVING BALLAST AND 40 WATT COOL WHITE TUBES. SEPERATE EXHAUST FAN WITH A 100 CFM AIR EXCHANGE REQUIRED. LARGE SUSPENDED PENDANT FIXTURE (SW/AST/10-PL). USES (1) 5W FLUO. LAMP (MAXLITE MLS15EA). PENDANT LIGHTS ARE PLACED AROUND THE PERIMETER OF THE RESTAURANT AND SHOULD BE INSTALLED AT A HEIGHT OF 6'-6" (198.1 cm FROM THE FLOOR TO THE BOTTOM OF THE FIXTURE. (A 'PENDANT. STEM KIT' IS AVAILABLE THROUGH SPECIALTY STORE LIGHTING FOR USE WITH HIGH CEILING) *RECOMMEND INSTALLING CUSTOMER SEATING BEFORE PENDANT LIGHTS TO ALLOW FOR PRECISE PLACEMENT OF FIXTURES OVER TABLE .TOPS.. SPECIALTY LIGHTING GROUP DAI CD -445 WITH 5 CHERRY FINISH.. BLADES. CAN BE: INSTALLED AS DROP STYLE (WITH 6" OR;2"..STEM) OR .HUGGER'. (FLUSH) STYLE.' 1 '-i i 1 1 I I.} 1 LS -1t1 -JJ 36" X 52"; X 5" WAVE MODULAR SOFFIT. COLOR FINISH: FONT HILL PEAR LAMINATE (WILSONART #10745-60) LIGHTING: (4)120V PRE -WIRED PLUG IN RECESSED 3 WATT LED LIGHT FIXTURES WITH. CHROME EXTERIOR RINGS. INSTALLATION MOUNTING HARDWARE PRE -ATTACHED AT FACTORY AND CONNECTED T FRAMING STRUCTURE WITH II" THREADED CONNECTING ROD. PerrnitNo.. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. ikVll T E: FoVisi('i s will require a new pian submittal and may include additional plan review fees. Jr r rev :w. approval is: subject to errors and omissions, .of construction documents does not authe Pae IfI '.:,i"�`lor o anya of}:,i ,:l d e or ordinance. Receipt rls 4 prov€d Field C +2. y ., d I Ins is acknowledged: EXISTING .STOREFRONT ,' , , FUR .I T Ul- F` AND - 7 UIFMENT Q LEGEN BUILDING DIVISION APR 3 0 2013 if -'7 - City of Tukwila ITEM MANUFACTURER - ORDERED FROM . QTY _ DESCRIPTION TT C V STOMER AREA 4A 30" X 42" TABLE PLYMOLD - .. DAI 1.30" WIGH. W/ (1) VERTICAL TABLE LEG. AT EACH OF THE :4 CORNERS. FONT HILL PEAR. LAMINATE WITH BLACK DURA 4B 20" X 24" TABLE PLYMOLD DAI :9 .EDGE. 30" HIGH W/ FREESTANDING 22" X 22" CROSS BASE.' FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 42" HIGH W/ FREESTANDING 30" X 30" CROSS BASE. FONT HILL PEAR LAMINATE WITH BLACK DURA EDGE. 5A 30" ROUND BAR HEIGHT TABLE PLYMOLD DAI .. 1 5D 24" ROUND BAR HEIGHT TABLE PLYMOLD ; DAI 2 42" HIGH. W/ FREESTANDING 22" X 22" CROSS BASE. FONT HILL PEAR. LAMINATE WITH BLACK DURA : EDGE: QUEST CHAIR W/ UPHOLSTERED SEAT OR DUR-A-SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK WRINKLE.. 6A CHAIR :: PLYMOLD. ; DAI 22 6B BAR HEIGHT STOOL : PLYMOLD DAI :. 7 QUEST STOOL W/ UPHOLSTERED SEAT OR DUR-A-SEAT TO BE ORDERED IN THE FOLLOWING COLORS: CROCUS, SPICE AND SLATE. FRAME COLOR IS BLACK 8A TRASH RECEPTACLE PLYMOLD DAI . 1 .WRINKLE. ( 1 . )25". X 25" SINGLE HOLE TRASH UNIT: BLACK DURA EDGE TRASH RECEPTICLE W/FONT HILL PEAR LAMINATE FINISH: 9A SODA FOUNTAIN : CORNELIUS DAL 1 DEDICATED 115V, 20 AMP DUPLEX .OUTLET. (NEMA 5-20R) W/IN 3 FEET, 3 INCH OR LARGER FLOOR DRAIN W/IN 3 FEET (EQUIPMENT INSTALLED BY COKE): 9B TEA COFFEE BREWER : BUNN-0-MATIC CORP...: DAI 1 DEDICATED 120V, 15 AMP DUPLEX OUTLET (NEMA 5-15P) W/IN 3 FEET. PLUMBING: 20-90 PSI. MODEL SUPPLIED.. WITH 1 4" MALE FLARE FITTING.: MIN. 1GPM WATER FLOW.. 10 BEVa'AGE DESTINATION CENTER DUKE MANUFACTURING DAI : 1 ( 1 . )72" RH BEVERAGE PLACEMENT:., STAINLESS STEEL TOP. FONT HILL : PEAR LA, ;NATE FINISH. INSTALLED BY G.C. 11 SUBWAY WE." WINDOW SIGN MYSTIGLO DAi . 1 SEE MANUFACTURER FOR SPECS.. 120V.. INSTALLED BY G.C. .. EM WALL ART -VERTICAL SUNGLO FABRICS. DAI . 3 23" X 50" WALL HUNG PRINT(S) ON STYRENE -FACED FOAMBOARD FRAMED IN BLACK METAL. MOUNTING HARDWARE INCLUDED. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. 26" X .26". WALL HUNG . PRINT(S) COLOR PHOTOS DOUBLE MATTED IN. A BLACK W1`ODEN FRAME. MOUNTING HARDWARE INCLUDED.. EIGHT DIFFERENT PRINT IMAGES AVAILABLE. 13B WALL ART- SQUARE . SUNGLO FABRICS DAI 2 14 CHIP RACK FRITO-LAY'' :DAI 1 (1)44 W x 16 3/8 D. x 68"H FLOOR RACK. LOCAL DIST 15 DISPLAY REFRIGERATOR TRUE :. DAI 1 (1)1 DOOR FLOOR MODEL. DEDICATED 115V, 15 AMP DUPLEX OUTLET (NEMA 5-15R) W/IN 6. FEET. 16 WALL PLANT. GRACE DESIGNS DAI 2 . WALL HUNG SILK :PLANT. . MOUNTING BRACKET TO BE HUNG 15" BELOW THE TOP OF THE UPPER DECORATIVE. MOLDING. (REFER TO TUSCANY II BACK-UP 17 INTERIOR DOOR . LOCAL G.C. 3. SHEET #1) SOLID CORE HARDWOOD DOOR (SLAB OR PANEL CONSTRUCTION) STAIN MINWAX #235 CHERRY & POLYURETHANE W/ MINWAX FAST DRYING SATIN. METAL FRAME (PAINT SHERWIN WIWAMS #SW6356 COPPER MOUNTAIN) LEVER HANDLE: INSTALLED BY GC.. .... SERVICE'... AREA 19 FRONT COUNTER DUKE MANUFACTURING DAI : 1 TOTAL LENGTH 17'-2". ( 1 ) 25" -RH-- HOT F000 UNITS .. 2 60°' COLDPAN �) ( ) At\ UNIT(S). (1 ) 61 `. CASH UNIT(S). STALLED BY G.C.G C ULS APPROVED: ELECTRICAL CONNECTIONS AND. WIRING . INSTALLED TO LO::AL AND STATE CODE REQUIREMENTS AS .DE DETERMINED BY G.C. OR ELECTRICIAN.:. 200 SKELETON WALL . DUKE MANUFACTURING DAI, 1 4 . i"D..X 24"W. X 35 3/4"H. WALL S.S. TOP. INSTALLED BY G.C. 21 COOKIE DISPLAY CASE ADVANCED DISPLAYS IN PLASTICS, INC DAI '. 1 DISPLAY CASE ON TOP OF SUB -WRAP AND NAPKIN RISER. MADE OF CLEAR ACRYLIC. 23 SAFE C.S:SJTIDEL DAI 1 (.1)TIME. LOCK. INSTALLED BY G.C. IN SERVICE AREA: 24 SUBSHOP 2000 P.O.S. MICROS SYSTEMS/DELL/IPC-POS MENUMASTER/SHARP DAI . DAI 1 1 PC BASED POINT OF SALE SYSTEM. REQUIRES DEDICATED POWER SOURCE WITH ISOLATED GROUND TO BREAKER. 25 MICROWAVE . *5=20R OUTLET REQUIRED. 1200 WATT, 12OV/60HZ/1PH, 20 AMP CIRCUIT. DEDICATED CIRCUIT REQUIRED. 27 BREAD OVEN DUKE/NU-VU LOCKWOOD/NU-VU LOCKWOOD DAI) DAI DAI. 1 1 1 �� (1 NU -VU. DEDICATED CIRCUIT REQUIRED. DIRECT WIRED. INSTALLED BY G.C. *1 4 WATERLINE IS REQUIRED. (.1.) RH. NU -VU. COMBINATION CABINET. INTEGRATED OPEN AIR COOLING RACK ABOVE WITH ENCLOSED CABINET BELOW. INSTALLED BY G.C. ( 1 ). RH LOCKWOOD. ALUMINUM .CABINET WITH ANGLED GLASS FRONT DISPLAY AND GLASS DOOR. INSTALLED BY G.C. NSF APPROVED. ' 28A COMB! BREAD CABINET 28C 29 FRONTLINE DISPLAY BREAD CABINET MENUBOARD VGS ./ TRANSLITE SONOMA DUKE MANUFACTURING : DAI . DAI 6 1 MENUBOARD:: ( 4 )2' X 4' ( 2 )2' X 2' - LIGHT FIXTURES: ( 2 )2' ( 1 )16'. MOUNT TO TOP OF MENUBOARD. SINGLE OUTLET REQUIRED. INSTALLED BY G C ( 1 )RH 72" LENGTH. STAINLESS STEEL TOP, FONT 31 BACK COUNTER W/ HAND SINK HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 33 REFRIGERATED: BACK COUNTER DUKE MANUFACTURING DAI : ; 1 . ( 1. )60" LENGTH. BACK COUNTER WITH UNDER COUNTER REFRIGERATOR. STAINLESS STEEL. TOP. FONT HILL PEAR LAMINATE FINISH. INSTALLED BY G.C. 34 RAPID COOK OVEN TURBOCHEF/MERRYCHEF DAI 1 ( 1 )MERRYCHEF. MICROWAVE/CONVECTION OVEN. REFER TO EQUIPMENT BACK-UP SHEET #2 FOR FURTHER SPECIFICATIONS ..: BACKROOM AREA ( 1 ) 3 COMPARTMENTS: 2 DRAINBOARDS (18"). INSTALLED BY G.C. ULS APPROVED. 36 SINK DUKE MANUFACTURING. DAI 1 37 MOP SINK . LOCALLY SOURCED .: G.C. 1 FLOOR LEVEL SINK. 2' X 2' (PREFERRED). ACQUIRE LOCALLY. INSTALLED BY G.C. 38 HOT WATER TANK LOCALLY SOURCED G.C. 1 ACQUIRE LOCALLY: INSTALLED BY. G.C. 39 S.S. WORKTABLE DUKE MANUFACTURING DAI 1 ( 1 ) 60" X 30" .. AVAILABLE WITH OR WITHOUT GALVANIZED UNDERSHELF. ORDER WITHOUT UNDERSHELF IF SODA IS STORED BENEATH TABLE. 40 WALL SHELF INTER METRO DAI .: 4 SUPER ERECTA BRITE. EPDXY COATED, WALL MOUNTED SHELVES, AVAILABLE IN . VARIOUS SIZES, INSTALLED BY G.C. 41 VEGETABLE SINK . DUKE MANUFACTURING DAI - 1 ( 1 )1 COMPARTMENTS. 1 DRAINBOARD. INSTALLED BY G.C. ULS APPROVED. 42 HAND SINK : DUKE MANUFACTURING / LOCAL DAI/G.C. 1 WALL MOUNTED; SUBJECT TO HEALTH CODE APPROVAL. OF I U1(WILA 43 CLEANING PRODUCT. RACK SSDC DAI 1 DISPENSING STATION FOR CLEANING PRODUCTS: C1T� 45 NEMCO EASY -SLICER NEMCO, INC. DAI : 1 MANUAL SLICER MOUNTED ON STAINLESS. STEEL TABLE TOP: NSF APPROVED: _0 46 RETARDER .ABINET :; LOCKWOOD : DAI 1 (1 )WALK.. -1N: NSF APPROVED: 47 REFRIGERATOR NORLAKE ., DAI 1 1 . ( 1 )6' X 6' SELF -EVAPORATING. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED. ,.. . 1 )6' . X 6' SELF -EVAPORATING. DIRECT WIRED. INSTALLED BY G.C. NSF APPROVED: PLRMrT�E 48 FREEZER NORLAKE : DAI : 49A STORAGE UNITS INTER METRO DAI 4 ( 2 )12". X 36" ( 1 )14" X 36" ( 1 )24' X 72" SUPER ERECTA BRITE. 49B OFFICE/TRAINING STATION INTER METRO DAI 1 ( 1 )24" X 30" X .74" S.S. WORK SURFACE WITH KEYBOARD DRAWER AND OVERHEAD SHELVING WITH .A LOCKABLE CAGE. SUPER ERECTA BRITE. 50 SODA STORAGE- . COKE . DAI 1 DEDICATED 115V, 20 AMP DUPLEX OUTLET (NEMA 5-20R) W/IN 3 FEET OF BIB RACK, 96 INCHES HIGH/WATER 1/2 INCH BALL VALVE SHUTOFF W/IN 3 FEET OF. BIB RACK, 96 INCHES HIGH (EQUIPMENT INSTALLED BY COKE). 51 STEREO SYSTEM , :� SUBWAY® RADIO/LOCAL DAI/LOCAL . 1 RECEIVER AND AMPLIFIER WITH THREE SPEAKERS MOUNTED AND PROFESSIONALLY WIRED IN OPTIONAL SUBWAY® RADIO SERVICE.: - - ..CEILING. EXISTING .STOREFRONT ,' , , REVIEWED FOR, CODE COMPLIANCE APPROVED APR 3 0 2013 if -'7 - City of Tukwila BUILDING DIVISION EXISTING .STOREFRONT ,' , , 30"X48" CLEAR .-SPACE REQUIRED TP:.s3�".fuIi3F.LI.Y i. G9P `1!Tiy:RM. PostNet-WA 113 assumes no liability or responsibility for plan use. It is the responsibility of the user to verify all dimensions and scale. SYMBOL LEGEND • — 120V DUPLEX OUTLET • - 220V SINGLE OUTLET — PHONE JACK. JUNCT,Oi4 BOX THERMOSTAT — ELECTI:IC PANEL F.M. -. FLOOR MOUNTED C.M. CEILINu MOUNTED -. FLOOR DRAIN - FLOOR SINK CEILING HEIGHT IS 9'-10 ELECTRICAL OUTLET HEIGHTS MEASURED. TO BOTTOM OF BOX. - ONE ELECTRICAL JUNCTION BOX TO BE LOCATED IN CEILING ABOVE EACH WINDOW.. -. CUNO MODEL SW3-PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION. IS MOUNTED TO SODA SYRUP RACK BY COCA-COLA. SECONDARY PLACEMENT, OPTION IS MOUNTED ON . THE BACKROOM WALL. THIRD INSTALLATION OPTION IS MOUNTING INSIDE THE FRONT BEVERAGE COUNTER WHEN SPACE. LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION. MINIMUM 110 VOLT, 20 ' AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE' DEDICATED CIRCUIT). - SMARTCURVE STAND (MFR. DISPLAY -BOX) REQUIRED IN CUSTOMER AREA AT POINT OF ,ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8" BASE, 56" (WITHOUT HEADER)OVERALL HEIGHT. -� . SECONDARY CHIP RACK IS REQUIRED IN THE CUSOMER .AREA. THE TWO AVAILABLE OPTIONS ARE: BASKET STYLE CHIP RACK AT THE. POINT OF ORDER (PREFERRED PLACEMENT) OR PURSE RAIL MOUNTED CHIP RACK. (MOUNTED ON TOP OF THE PURSE RAIL) • - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EMERGENCY LIGHTS INSTALLED BY G.C. PER LOCAL CODE. - EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS INSTALLED BY G.C. PER LOCAL CODE.. - LABOR & MATERIAL SUPPLIED BY G.C. UNLESS. OTHERWISE NOTED. - ALL DIMENSIONS TO BE . VERIFIED BY G.C. ON SITE.. - DECOR SPECIFICATIONS ARE .TO. BE SUBWAY'S "TUSCANY II" SCHEME. r7 t1'-1116.. 4' 51" Mir 0 M 1- F - A4.01 03 �:a �:T► Tiog Aa® �D iW Wr• > ftz.. km s ' 3!2 13r az-731k,`r. I 1 �giur Wir 1C112®©:3 IlwMaittiMENE F. Av NOP •T" R f'1 4D 4©0 it 0 FLOOR AND WALL FINISH PLAN SCALE: 1/4" ,t 32' • NORTH 24'-7" 111111r' 1111111 1111111.1111111 I. 3' 1 1.96 NiJ 11111P J g:1rr.L^:nffiu"ae111741-�7�., +106" • 1111111 1111111 .4111111 • MEM M:IMUM unnr1111111 11111th. (111111 Irk: 1%x—K17—all 1111=111 ®am u,E 444' 7 w. t.s 7'7" !°" 3 0. X 6 :. .1' ,,{{,pp.. r Tir II t� ..F9pEVI �/r 111111g0241114, 1)./ 2Br5. e�. I j�nt ' .�7 L54•!3!:i£it'k'.i 7 tallai t I 31. • II ZiY;v A4.01 1c+_I I1I 11F 1107=' 19' -3" I!) 41 LUL. 1 1S It ELECTRIC AND DIMENSION PLAN r• -7- SCALE: NORTH. WALL FINISHFINISH.. 'L EG NDTUSCA N y IDECOR) *SEE TUSCANY II BACK—UP SHEET 1 OF 2 AND :2 OF 2 FOR PROPER INSTALLATION OF WALLFINISHES IN CUSTOMER AND (SEE TUSCANY SUPPLEMENTAL TILE . BACK—UP SHEET WHEN APPLICABLE) SERVICE AREAS. FLOOR.: FINISH LEGEND - TILE TUSCANY . II :DECOR (RANDOM PATTERN SYMBOL DESCRIPTION MANUFACTURER SUPPLY INST. NOTES: NO.. AREA or .SWORE MANUFACTURER ,Q. M TS QUENTIN WALLCOVERING SUBWAY MURAL WALL COVERING TUSCAN STUCCO WALLCOVERING QUENTIN: WALLCOVERING SUNGLO FABRICS SUNGLO FABRICS SUNGLO.FABRICS SUNGLO FABRICS WINDOW FRAME TUSCAN STUCCO WALLCOVERING RED,: WALL COVERING TUSCAN STUCCO WALLCOVERING BUTTERNUT BRICK WALL COVERING SUNGLO FABRICS SUNGLO FABRICS SUNGLO FABRICS SUNGLO FABRICS D.A.I. D.A.I. D.A.I. D.A.I. G.C. DA.I. D.A.I. D.A.I.. D.A.I. G..C.. G.C. G.C. G. C. G.C. G,C, G.C. G.C. G.C. VINYL WALLCOVERING VINYL: WALLCOVERING (WITH UPPER DECORATIVE TRIM MOLDING AS REQUIREDL VINYL WALLCOVERING.-(WITH LOWER .CHAIR RAIL MOLDING AS REQUIRED) VINYLL.WALLCOVERING. , PAINT SHERWIN .WILLIAMS #SW6356 .COPPER MOUNTAIN. (WITH CITYSCAPE MURAL •& UPPER DECORATIVE TRIM MOLDING .AS. REQUIREDZ VINYL WfiLLCOVERING..REQUIRED) WITH LOWER.CHAIR RAIL MOLDING (AS Q ) : VINYL • WALLCOVERING CUSTOMER AREA CROSSVILLE SUPPLIER G.C. INST. G.C. SQ/FT 570 DESCRIPTION COLORBLOX STONE SERIES; 12".X 12" A1156 WHEAT COLORBLOX STONE SERIES; 12" X 12" ` A1154 GREEN COLORBLOX STONE SERIES; 12" X 12" A1153 CLAY WHEN INSTALLING THE RANDOM PATTERN, THE PERCENTAGES OF THE ABOVE COLORS ARE AS FOLLOWS WHEAT ._ 80%; GREEN 12%;CLAY 8%. (THE GREEN AND CLAY SHOULD BE DISTRIBUTED EVENLY, : BUT RANDOMLY THROUGHOUT AS NOT TO REPRESENT A NOTICEABLE PATTERN) USE DARK GREY OR DARK BROWN GROUT THROUGHOUT ENTIRE CUSTOMER AREA PUBLIC ACCESSIBLE RESTROOM CROSSVILLE G.C. G.C. 80 COLORBLOX STONE SERIES; T E1 2 X 12" A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT VINYL WALLCOVERING LOWER CHAIR RAIL MOLDING) VINYL:WALLCOVER G IN SERVICE/ BACKROOM AREA CROSSVILLE G.C. G. ARMSTRONG G.C. G.C. 450 OPTION #1:COLORBLOX STONE. SERIES; 12" X 12" A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. RUT.. OPTION2. 51830 COLOR: COTTAGE ,T N # A 12"X 12 VINYL COMPOSITETILE CONTINUED THROUGHOUT THE BACKROOM. CABINET/WALL: LAMINATE WILSONART G. G.C. FONT -HILL PEAR 10745-60. INSTALL GRAIN. HORIZONTALLY MOSAIC TILE ' ARIGHT VACUFORM / WILSONART D.A. G. MOSAIC, TILE .. (LEFT) VACUFORM/ WILSONART D.A.I. G. GRAPHIC IMAGES (SEE TUSCANYII BACK-UP SHEETFOR DETAILS AND OPTIONS) WITH WILSONART #10745-60 FONTHILL PEAR BORDER AND 4" LIGHTED PURSE RAIL GRAPHIC I1. AGES (SEE TUSCANY 11 BACK—UP SHEET FOR DETAILS AND OPTIONS) WITH :WILSCNART;#10745-60 FONTHILL PEAR BORDER AND 4" LIGHTED PURSE. RAIL. WALL ; BASE NOTE: WALL BASE OPTION MUST MATCH FLOOR OPTION LISTED ABOVE IN ALL AREAS OF STORE ALL AREAS CROSSVILLE L E G.C. G.C. SERVICE/BACIfR00M AREA ARMSTRONG G. G.C. PAINTED WALL. FIBERGLASS. REINFORCED POLYESTER. PANELS (FRP SHERWIN WILLIAMS M ARLITE .C: PAINT( $HERWIN WiL I S OFF- ` TE SEMI -GLOSS S AM WHI FIN( H L ) DAI/GC G. FRP: PANELS :;= WATERY..RESISTANT COVERING: WHITE , OR *ALMOND (*ALMOND OPTION ONLY IF PERMITTED BY HEALTH/BUILDING 'CODE). (T: 117 RESTROOM: ; TILED WALLS CROSSVILLE G.C. G.G. COLORBLOX STONE FLOOR TILE MOUNTED FLOOR TO CEILING CHOOSE1OR MORE OF. THE FOLLOWING: .A1153 .CLAY, A1154 GREEN, A1156 WHEAT 6" X 12" COVE BASE OR. 4" X 12" BULLNOSE: COLORBLOX STONE. SERIES A1156 WHEAT WITH DARK GREY OR DARK BROWN GROUT. 6” BLACK VINYL COVE BASE. USED WITH VINYL COMPOSITE. ( , .FLOOR TILE ONLY) ADDITIONAL COMMENTS: 1.) FLOORING CONTRACTOR IS RESPONSIBLE F0 R OWN DET R MINATIONS ON SU F LO R REQUIREMENTS ENTS AND TO INSTALL IN ACCORDANCE WITH CODE REQUIREMENTS AND TO INDUSTRY AND MANUFACTURER SPECIFICATIONS: 2.) THE SQUARE FOOTAGE CALCULATIONS OF THE FLOORING. MUST; BE VERIFIED BY 'G.C. AND THE FRANCHISE OWNER. SUBWAY STORE DESIGN DEPARTMENT WILL NOT ACCEPT RESPONSIBILITY CFOR ANY INACCURACIES. 3) BULLNOSE WALL BASE IS TO BE INSTALLED ON TOP OF THE. TUSCAN STUCCO WALL COVERING. 1"--3 OF TUSCAN STUCCO WALL COVERING IS N-. RECOMME DED TO BE COVERED , TO. PROVIDE A TIGHT FIT. NOTE: ALL WOOD.: • �.` INTERIOR DOORS, ;UPPER & LOWER MOLDING & CROWN MOLDING TO BE STAINED WITH MINWAX#235:: CHERRY AND POLYURETHANED MINWAFAST::DRYING CLEAR :SATIN; NOTE: INSTALL F.R.P. VERTICALLY IN THE BACKROOM TO A MINIMUM HEIGHT OF S'=. ABOVE FINISHED FLOOR. TUSCANY II D'COR CALL ULA TIONS NOTE: THE :SUBWAY STORE DESIGN DEPARTMENT WILL NOT ACCEPT 'RESPONSIBILITY FOR ANY INACCURACIES. THE CALCULATIONS PROVIDED BELOW MUST BE VERIFIED BY. THE G.C. AND FRANCHISE OWNER BEFORE ANY ORDER FOR THESE MATERIALS IS ACCEPTED AND PLACED: QUANTITIES CALCULATION WORKSHEET. CUSTOMER AREA. 1) (36YARDS CITYSCAPE MURAL 2) ( 40 ) YARDS OF TUSCAN STUCCO WALL COVERING 3 (110 FEET OF UPPER DECORATIVE MOLDING.. 41.18 FEET OF LOWER CHAIR RAIL MOLDING 5 ,( 27 YARDS OF QUENTIN WALL COVERING (NON—TEDLAR) ABOVE CITYSCAPE MURAL AND SOFFIT. 6) (- ) YARDS OF BUTTERNUT BRICK WALL COVERING ABOVE CITYSCAPE MURAL AND SOFFIT. 7)' (-) (OPTIONAL)FEET OF HARDWOOD CROWN MOLDING (AT CORNER: WHERE WALL AND .CEILING MEET) 8) . ( ) FEET. OF HARDWOOD CROWN MOLDING 9) ( 3.) (ARDS OF RED WFINH CAP ON ALLPCOVER NG LIGHTING SHELF), 10) (- . ) YARDS OF. QUENTIN WALLCOVERING (WITH TEDLAR COATING) (FOR 48" HIGH BANQUETTE. WALL ONLY) 2' 3 4 5) 6). 7) 8) 9) 10) Q/M/TS 'OR B/M/TS + S/M Q/M/TS OR B/M/TS + T/S Q/M/TS OR B/M/TS + S/M' Q/M/TS OR B/M/TS + 1'/S (CEILING HEIGHT — 7'-6") X + 5% DIVIDED BY 12 (CEILING HEIGHT - 7'-6") X + 5%`DIVIDED 'BY 1.2 Q/M/TS OR B/M/TS + S/M + :10% DIVIDED BY 3. + R/TS 10% DIVIDED BY 3 + 10%. + R/TS: 10% .. (Q/M/TS + S/M + (Q/WC CUSTOMER AREA & SOFFIT ONLY)) (B/M/TS + S/M + (B/T IN CUSTOMER AREA & SOFFIT ONLY)) + R/TS (+ W/TS IF WINDOWS NOT TO CEILING) + 10%. TOTAL LENGTH OF WALLS WHERE FLUORESCENT STRIP LIGHTING TO BE INSTALLED + 10% HEIGHT FROM TOP OF 'TUSCAN STUCCO. WALL COVERING TO CEILING (36" A.F.F.) X R/TS + 5% DIVIDED BY 12 QT/WC + 10% DIVIDED BY 3, (CUSTOMER AREA ONLY) 9 RANDOM FLOOR TILE PLACEMENT EXAMPLE FLOOR TILE KEY SERVICE AREA 11) ( — ) 4' X.12' 'SHEETS. FONT -HILL PEAR LAMINATE* 12) ( ) 12' T -MOLDING STRIPS *. 13) ( 33 YARDS OF BUTTERNUT BRICK WALL COVERING (WALLS ONLY) 14) ( ) YARDS OF QUENDN WAIT COVERING (WITH TEDLAR COATING) (WALLS ONLY) 15) iRIGHT ( 1 )LEFT VEGETABLE MOSAIC TILE. 16)) .(OPTIONAL) FEET OF COPPER CORNICE TRIM 17 -) 4'.:X 12' SHEETS FONT -HILL PEAR LAMINATE (OPTIONAL:. FOR SOFFIT APPLICATION) 11) FP/L + 5% DIVIDED BY 12 12) (FP/L ON 36" HIGH WALLS X 2) + (FP/L: ON 48" HIGH WALLS X 3) .+ 5% DIVIDED BY 12 13) CEILING HEIGHT X B/T + 5% DIVIDED BY 12 14) CEILING HEIGHT X QT/WC' + . 5% DIVIDED BY 12 16) TOTAL LENGTH OF CUSTOMER SIDE OF HEADERWALL(S) OVER SERVICE AREA + 5% BACK ROOM 18) (17) MARLITE: F.R.P. .WHITE (ALMOND OPTIONAL IF PERMITTED BY HEALTH/BUILDING CODE) 19) (16 PVC DIVISION MOLDING 20) 5 PVC INSIDE CORNER 21) 1 PVC OUTSIDE CORNER 22) : 6 PVC CAP MOLDING 18) W/R + 5% DIVIDED .BY 4 19 PANEL COUNT FROM #18 LESS 1 20) COUNT ALL INSIDE CORNERSE E W R MEET WH R 21) COUNT ALL OUTSIDE CORNERS ; WHERE W/R MEET 22) COUNT ALL EDGES WHERE W/R BEGINS & ENDS & DOORWAYS. * CALCULATIONS ARE FOR FONT -HILL PEAR LAMINATE AND ALUMINUM .T -MOLDING APPLIED TO 36" AND: 48" HIGH WALLS. WHEN AFFIXED DIRECTLY TO DUKE FRONT COUNTER, IS SHIPPED . READY TO INSTALL. BY DUKE MANUFACTURING. LAMINATE. AND T—MOLDING, NOTE: THESE CALCULATIONS DO NOT INCLUDE THE MATERIALS NEEDED TO DECOR THE AREA ABOVE OR BELOW THE WINDOWS: PostNet WA 113 assumes no liability or responsibility for plan use, it is the responsibility of the user to verify all dimensions and scale. N OCATION REVIEWED FOR CODE COMPLIANCE APPROVED. APR 30 2013 City of Tukwila BUILDING DIVISION RECEIVED APR 16 2013 TUKWlu-k PUBLIC WORKS RECEIVED CITY OF T.UKWILA APR 022013 PERMIT CENTER ?G1' 0L41 SYMBOL LEGEND - 120V DUPLEX OUTLET • 220V SINGLE OUTLET - PHONE JACK JU - JUNCTION BOX OT - THERMOST.VT. - ELECTRIC PANEL F.M. - FLOOR MOUNTED C.M. -. CEILING MOUNTED ® - FLOOR DRAIN • FLOOR SINK '1'', - CEILING HEIGHT IS 9'-10" - ELECTRICAL OUTLET HEIGHTS MEASURED. TO BOTTOM OF BOX. ONE ELECTRICAL JUNCTION BOX TO BE: LOCATED. IN CEILING ABOVE EACH WINDOW. - CUNO MODEL SW3-PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED :TO SODA SYRUP RACK BY COCA-COLA. SECONDARY PLACEMENT OPTION IS . MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION . IS MOUNTING INSIDE THE. FRONT BEVERAGE COUNTER WHEN SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION.' MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). — SMARTCURVE STAND (MFR. DISPLAY -BOX). REQUIRED IN CUSTOMER AREA AT. POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8 BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT: — SECONDARY CHIP RACK IS REQUIRED IN THE CUSTOMER AREA. THE TWO AVAILABLE OPTIONS ARE: BASKET STYLE CHIP. RACK AT THE POINT OF ORDER (PREFERRED PLACEMENT) OR PURSE RAIL MOUNTED CHIP RACK. (MOUNTED ON TOP OF THE PURSE RAIL.) - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. — EMERGENCY. LIGHTS INSTALLED BY G.C. PER LOCAL CODE.. - EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS . INSTALLED BY G.C. PER LOCAL CODE LABOR & MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. - ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE:: DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. SUBMITTAL PERMIT SUBMITTAL w 1- 0 ce w 0 z ott COLORBLOX SERIES; 12" X 12" A1156 WHEAT COLORBLOX. SERIES; 12" X 12" A1154 GREEN COLORBLOX SERIES; 12" X ..12" A1153 CLAY SERVICE AREA 11) ( — ) 4' X.12' 'SHEETS. FONT -HILL PEAR LAMINATE* 12) ( ) 12' T -MOLDING STRIPS *. 13) ( 33 YARDS OF BUTTERNUT BRICK WALL COVERING (WALLS ONLY) 14) ( ) YARDS OF QUENDN WAIT COVERING (WITH TEDLAR COATING) (WALLS ONLY) 15) iRIGHT ( 1 )LEFT VEGETABLE MOSAIC TILE. 16)) .(OPTIONAL) FEET OF COPPER CORNICE TRIM 17 -) 4'.:X 12' SHEETS FONT -HILL PEAR LAMINATE (OPTIONAL:. FOR SOFFIT APPLICATION) 11) FP/L + 5% DIVIDED BY 12 12) (FP/L ON 36" HIGH WALLS X 2) + (FP/L: ON 48" HIGH WALLS X 3) .+ 5% DIVIDED BY 12 13) CEILING HEIGHT X B/T + 5% DIVIDED BY 12 14) CEILING HEIGHT X QT/WC' + . 5% DIVIDED BY 12 16) TOTAL LENGTH OF CUSTOMER SIDE OF HEADERWALL(S) OVER SERVICE AREA + 5% BACK ROOM 18) (17) MARLITE: F.R.P. .WHITE (ALMOND OPTIONAL IF PERMITTED BY HEALTH/BUILDING CODE) 19) (16 PVC DIVISION MOLDING 20) 5 PVC INSIDE CORNER 21) 1 PVC OUTSIDE CORNER 22) : 6 PVC CAP MOLDING 18) W/R + 5% DIVIDED .BY 4 19 PANEL COUNT FROM #18 LESS 1 20) COUNT ALL INSIDE CORNERSE E W R MEET WH R 21) COUNT ALL OUTSIDE CORNERS ; WHERE W/R MEET 22) COUNT ALL EDGES WHERE W/R BEGINS & ENDS & DOORWAYS. * CALCULATIONS ARE FOR FONT -HILL PEAR LAMINATE AND ALUMINUM .T -MOLDING APPLIED TO 36" AND: 48" HIGH WALLS. WHEN AFFIXED DIRECTLY TO DUKE FRONT COUNTER, IS SHIPPED . READY TO INSTALL. BY DUKE MANUFACTURING. LAMINATE. AND T—MOLDING, NOTE: THESE CALCULATIONS DO NOT INCLUDE THE MATERIALS NEEDED TO DECOR THE AREA ABOVE OR BELOW THE WINDOWS: PostNet WA 113 assumes no liability or responsibility for plan use, it is the responsibility of the user to verify all dimensions and scale. N OCATION REVIEWED FOR CODE COMPLIANCE APPROVED. APR 30 2013 City of Tukwila BUILDING DIVISION RECEIVED APR 16 2013 TUKWlu-k PUBLIC WORKS RECEIVED CITY OF T.UKWILA APR 022013 PERMIT CENTER ?G1' 0L41 SYMBOL LEGEND - 120V DUPLEX OUTLET • 220V SINGLE OUTLET - PHONE JACK JU - JUNCTION BOX OT - THERMOST.VT. - ELECTRIC PANEL F.M. - FLOOR MOUNTED C.M. -. CEILING MOUNTED ® - FLOOR DRAIN • FLOOR SINK '1'', - CEILING HEIGHT IS 9'-10" - ELECTRICAL OUTLET HEIGHTS MEASURED. TO BOTTOM OF BOX. ONE ELECTRICAL JUNCTION BOX TO BE: LOCATED. IN CEILING ABOVE EACH WINDOW. - CUNO MODEL SW3-PLUS WATER FILTRATION SYSTEM IS REQUIRED IN ALL NEW STORES THAT DISPENSE BEVERAGES. THE RECOMMENDED PLACEMENT FOR INSTALLATION IS MOUNTED :TO SODA SYRUP RACK BY COCA-COLA. SECONDARY PLACEMENT OPTION IS . MOUNTED ON THE BACKROOM WALL. THIRD INSTALLATION OPTION . IS MOUNTING INSIDE THE. FRONT BEVERAGE COUNTER WHEN SPACE LIMITATIONS OCCUR. REQUIRED: 1/2" INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF AND 1/2" FPT CONNECTION.' MINIMUM 110 VOLT, 20 AMP ELECTRICAL SERVICE TO SUPPORT THE CARBONATOR AND WATER BOOSTER (MUST BE DEDICATED CIRCUIT). — SMARTCURVE STAND (MFR. DISPLAY -BOX). REQUIRED IN CUSTOMER AREA AT. POINT OF ORDER (PREFERRED PLACEMENT). 21 3/4" X 13 1/8 BASE, 56" (WITHOUT HEADER) OVERALL HEIGHT: — SECONDARY CHIP RACK IS REQUIRED IN THE CUSTOMER AREA. THE TWO AVAILABLE OPTIONS ARE: BASKET STYLE CHIP. RACK AT THE POINT OF ORDER (PREFERRED PLACEMENT) OR PURSE RAIL MOUNTED CHIP RACK. (MOUNTED ON TOP OF THE PURSE RAIL.) - EXIT LIGHTS INSTALLED BY G.C. PER LOCAL CODE. — EMERGENCY. LIGHTS INSTALLED BY G.C. PER LOCAL CODE.. - EXTINGUISHERS, SMOKE AND FIRE DETECTION SYSTEMS . INSTALLED BY G.C. PER LOCAL CODE LABOR & MATERIAL SUPPLIED BY G.C. UNLESS OTHERWISE NOTED. - ALL DIMENSIONS TO BE VERIFIED BY G.C. ON SITE:: DECOR SPECIFICATIONS ARE TO BE SUBWAY'S "TUSCANY II" SCHEME. SUBMITTAL PERMIT SUBMITTAL w 1- 0 ce w 0 z ott