Loading...
HomeMy WebLinkAboutPermit PG13-057 - NORMED - GAS PIPINGNORMED 4320 S 131 PL PG1 3-057 City otikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Project Name: NORMED PLUMBING/GAS PIPING PERMIT Permit Number: PG13-057 Issue Date: 05/06/2013 Permit Expires On: 11/02/2013 Owner: Name: NORMED SHAW PTN Address: PO BOX 3644 , SEATTLE WA 98124 Contact Person: Name: ALEX BURKHART Address: 727 S KENYON ST , SEATTLE WA 98108 Email: ALEXB@EVERGREENHVAC.COM Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 206 763-1744 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF GAS PIPING FOR (4) ROOFTOP UNITS REVISION #1: ADD (2) GAS PIPING OUTLETS Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $2,500.00 Uniform Plumbing Code Edition: 2009 $183.75 International Fuel Gas Code Edition: 2009 Date: '"%9/3-- /3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: A{t& C.uy0-4,A-- Date: 5 (23/l3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. IA IS nn4o nc7 D,;..+n.d. AR_11_')A PERMIT CONDITIONS Permit No. PG 13-057 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. d.,,.• I ID/`_1/111 P(mn57 Printed! 05-23-2013 Parcel No.: Address: City of'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 7349200095 4320 S 131 PL TUKW Project Name: NORMED PLUMBING/GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG 13-057 05/06/2013 11/02/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: NORMED SHAW PTN PO BOX 3644 , SEATTLE WA 98124 ALEX BURKHART 727 S KENYON ST , SEATTLE WA 98108 ALEXB @ EVERGREENH VAC. C OM Phone: 206 763-1744 EVERGREEN REFRIGERATION LLC Phone: 206 763-1744 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF GAS PIPING FOR (4) ROOFTOP UNITS REVISION #1: ADD (2) GAS PIPING OUTLETS Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie $2,500.00 $120.75 x• wit Uniform Plumbing Code Edition: International Fuel Gas Code Edition: 2009 2009 Date: ned this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Ui Print Name: 13vy- Date: 1-' u V3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. nl�An nv7 n_:._l-J. nL INC '1114 .3 • PERMIT CONDITIONS Permit No. PG 13-057 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PG13-057 Printed: 05-06-2013 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. \Gr DC Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: \,1326) S. iV. Tenant Name: No r tGA King Co Assessor's Tax No.: 3412'1)1)431 5 Suite Number: Floor: New Tenant: ❑ Yes ..No PROPERTY OWNER Company Name: rty6A-1 b Name: Aim, Nff-- Name: pooh( j 9, _ _ pr Tukwila Business License No.: Bus _ Da rt 2-$ —77 Address: p D bo . -,,c4,4 Zip: 4 og City: 56060,2_State: , - vi W pc Zip: itq ( ? CONTACT PERSON — person receiving all project communication Company Name: rty6A-1 b Name: Aim, Nff-- City: sceiwtc State: W k Zip: cf, q to -13 Phone: i 6 __-761,_ rig 4 Fax: 7/0c ,--76,-5 — Z) 8 et Address: 7n.,/ $atil [44444/61,‘ 54_ . Tukwila Business License No.: Bus _ Da rt 2-$ —77 City: < 4.t, State: Iv1A Zip: 4 og Phone: ?oto _--76„) — h y 4 yuj�Fax: 74)6_-70 , - vi Email: q,t'ALQNero\rctnkvi-c.tovn PLUMBING CONTRACTOR INFORMATION Company Name: rty6A-1 b Address: 12-1 so til s'. , City: sceiwtc State: W k Zip: cf, q to -13 Phone: i 6 __-761,_ rig 4 Fax: 7/0c ,--76,-5 — Z) 8 et Contr Reg No.: 1)v LA5c4 app Date: 1 /G 44 Tukwila Business License No.: Bus _ Da rt 2-$ —77 Valuation of Project (contractor's bid price): $ 2 5c50.073 Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: H:Wpphcations\Porms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/opiping outlets being installed and the quantitikow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER�OR_AUTHORIZED AGENT: Signature:_ II/1/p Date: t-%/ l0 /13 Print Name: AA. 1, Day Telephone: Z" .6 —1 3 1 \-1 4 Mailing Address: 1 2-1 SuNkk 1,<Auf Gin Si- • .S 4 S 1 0.16 H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Suite No: Applicant: NORMED RECEIPT Permit Number: Status: Applied Date: Issue Date: PG13-057 ISSUED 04/19/2013 05/06/2013 Receipt No.: R13-01722 Initials: User ID: WER 1655 Payment Amount: $63.00 Payment Date: 05/23/2013 10:43 AM Balance: $0.00 Payee: EVERGREEN REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. ACCOUNT ITEM LIST: Description 005946 63.00 Account Code Current Pmts GAS - NONRES 000.322.103.00.00 Total: $63.00 63.00 Ann• 1:72GPG1n+-nR Printed: 05-23-2013 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Suite No: Applicant: NORMED RECEIPT Permit Number: PG 13-057 Status: APPROVED Applied Date: 04/19/2013 Issue Date: Receipt No.: R13-01531 Payment Amount: $24.15 Initials: JEM Payment Date: 05/06/2013 12:15 PM User ID: 1165 Balance: $0.00 Payee: EVERGREEN REFRIGERATION, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 005926 24.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 24.15 Total: $24.15 prim.* na_na_)n1z C#, of Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 04-19-2013 at 12:49:33 04/19/2013 RECEIPT NO: R13-01367 Initials: JEM Payment Date: 04/19/2013 User ID: 1165 Total Payment: 899.31 Payee: EVERGREEN REFRIGERATION, LLC SET ID: S000001967 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount EL13-0366 92.40 M13-072 710.31 PG13-057 96.60 TOTAL: 91-T1M TRANSACTION LIST: Type Method Description Amount Payment Check 005901 899.31 TOTAL: 899.31 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.103.00.0 000.322.102.00.0 000.345.830 92.40 96.60 568.25 142.06 TOTAL: 899.31 V(9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type f.lns ° Ad4 3 Zo / 3 (�`'/'L Date _ 111&IA-L G Special Instructions:st l V C/� l , 1 3}� `1 Lr u.313- .1 Date Wanted: -�a�.. / '- 3',.' �3 p.m. Requester: Phone CO 401741 — 3 t 3 7. Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 r Insp ctor: n REINSPECTION FEE REQUIRE . P for to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date 3 t 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 k (206) 431-3670: Permit Inspection Request Line (206) 431-2451 106( 01 3- Project , o r M c TYE. } - of U Inspection: �r tet' Address:� 4 3Special / 3 F [ / L Date Called: Instructions: - Date Wanted:,a.m. _ Qa.m. Requester: Phone No- _ Co/ i-3137 JApproved per applicable codes. D Corrections required prior to approval. COMMENTS: R 1!TSPECTION FEE REQUIRED. Prior next inspection, fee,mu b aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. �ERM1T COORD COP*( -PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-057 PROJECT NAME: NORMED DATE: 05/06/13 SITE ADDRESS: 4320 S 131 PL Original Plan Submittal Response to Correction Letter #_ Response to Incomplete Letter # X Revision # 'I after Permit issued DEPARTMENTS: os'�9- Building Division EN Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 11.7/, Incomplete ❑ DUE DATE: 05/07/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 06/04/13 Approved \RIApproved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PERMIT COORD GOP%� PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-057 DATE: 04/19/13 PROJECT NAME: NORMED SITE ADDRESS: 4320 S 131 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: � U `ii3 BGilding I ISIon 3:1; i' 1a1A Public Works Fire Prevention Structural El Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 17Q, Incomplete ❑ DUE DATE: 04/23/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/21/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: r. PROJECT NAME: 1\a - \A SITE ADDRESS: 1-k9J9ro S X31 PL PERMIT NO: PG-t9D-- ORIGINAL ISSUE DATE: O4`'W REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS (G -CU s S- z3y 13 Wk Summary of Revision: hon f 1 Q L) &- O111 Received by: AleAL13w jug" - REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please pant REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print City of Tukwila REVISION SUBNIITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5 l 13 Plan Check/Permit Number: P 1 - os Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: t j 0v-tAtrcl Project Address: 3 2 0 S- 151 53:- p 1. Contact Person: \3w Summary of Revision: Phone Number: 7�v6-7 3 [-NNN e>`i.v1r ?it �, it_ A—�vt. Cs). Sheet Number(s): Z' "Cloud" or highlight all areas of revision including date of revision RECENED nnry 17,E TU (wIL* MAY 0 6 2013 PERMR CENTER Received at the City of Tukwila Permit Center by: Entered in Permits Plus on n( 0 112Q H:\Applications\Forms-Applications On Lme\2010 Applications\7-2010 - Revision SubmMaLdoc Revised: May 2011 Contractors or Tradespeoplefinter Friendly Page General/Specialty Contractor A business registered as a construction contractor with LFII to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING Et ENGY Construction Contractor General Unused 4/20/2009 4/20/2015 Active EVERGI"201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner/Member 12/22/2005 Bond Amount PATTON, DAVID Partner/Member 01/06/2006 WA15097 PATTON, RODGER Partner/Member 01/06/2006 PATTON, MATTHEW Partner/Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/15/2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2013 $1,000,000.00 07/29/2012 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003/23/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns: //fortress.wa. aov/lni/bbin/Print.asnx 05/06/2013 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.3.4.2 AN. OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE DUCTWORK GENERAL NOTES 1.1. ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS. OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. ALL DUCT GAUGES PER SMACNA, IMC 603-4. ALL DUCT SUPPORTS PER SMACNA, IMC 603-10.' 1.7. ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2. INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES: GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND. DIMENSIONS WITH ERL EEFORE FRAMING OPENINGS. GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. . GENERAL C3NTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE.601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. ' 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. BUILDING OWNER PER WSEC SECTION 1416.3.4.1 ALL HVAC SYSTEMS SHALL BE. BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.3.2.1. FOR WAREHOUSES SEMIHEATED SPACES, AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED. AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.3.3. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.3.3. NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.3.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.3.4.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4 AIRFLOW CFM COOLING SEER HEATING WEIGHT TOTAL RTU 3,4 LENNOX KGA060S4D 65,000 FILTER SIZES NO. (LxWxD) 4(16"x20"x2") LENNOX, KGA036S4D 37,500 105,000 84,000 4(16"x20"x2") NOTE; ,1. PACKAGED ROOFTOP UNIT: 2. ALL POWER WIRING (BY E.C.) '.'VIDE 100% 0..' . CONOMIZER & ROOFCURB. MODEL LOCATION NOTES EF 1 BROAN LOCATED ON CEILING BROAN BROAN BROAN BROAN LOCATED ON CEILING L150 130 0.375" 115 1 1.4 A LOCATED ON CEILING L150 130 0.375" 115 1 1.4 A LOCATED ON CEILING L150 130 0.375" 115 1 1.4 A LOCATED ON CEILING L200. 0.125" LOCATED ON CEILING LOCATED ON CEILING 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 • ERL TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 , ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER.. ENERGY CODE COMPLIANCE 5.2 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE APERUTOMATWSEC SICALLY EC . 1412.4WHEN.1. THE SYSTEM IS OFF OR UPON POWER FAILURE, 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COM 'LY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. NOTE: 1. CONTROLLED BY LIGHT SWITCH 2. ERL TO PROVIDE LINE VOLTAGE THERMOSTAT, OTHERS TO INSTALL SYMBOL BDD SYMBOL LEGEND ABBV. MVD BDD MD FD FSD SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical i= Plumbing 0 Gas Piping City of Tukwila UI13 ?NG DIVISION DESCRIPTION DUCT SECTION SUPPLY DUCT. SECTION - RETURN/EXHAUST RECTANGULAR DUCT ROUND DUCT FLEXIBLE DUCT MANUAL VOLUME DAMPER BACKDRAFT DAMPER MOTORIZED DAMPER FIRE DAMPER FIRE/SMOKE DAMPER (120V POWER REQ.) CEILING RADIATION DAMPER SMOKE DETECTOR THERMOSTAT SENSOR REFRIGERANT LINES VA2004#1 REVIEWED FOR CODP COMPLIANCE APPROVED FILE COP Permit No. t -- CI Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize trl:: Lrtofation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: NATURAL GAS LINES MAY 13 2013 n/ J '*1i3. BUILDING DIVISION FAX (206) 763 - 2389 (206) 763 1744 WASHINGTON 98108 NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC-. LIMED OR DISTRIBUTED TO OTHERS, SOLD, PUB •LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE CDNPEN-• SATION.TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE DF ACCEPTANCE OF THESE RESTRICTIONS. • 0 o .o w U N Q �- < M �( -J REVISIONS NO DATE ITEM 4/30/13, GEN. REV: QC Cr DRAWING DATE: j 04/10/13 Lu DWG. BY: %1 ic? CEILING DIFFUSER (SUPPLY) GN CEILING DIFFUSER (RETURN/EXHAUST) EXHAUST FAN (CEILING MOUNT EeiRECEIVED TY OFTimm INLINE FAN PROPELLER FAN REVISIONS No changes shall be made to the scope ofwork without prior approval of Tukwila Building Division. NOTE: flovisians will require a new plan submittal end may include additional plan review fees. P SIDEWALL DIFFUSER DUCT' FITTING MAY n 6 2013 RMIT CENTER JOB NO.: 513196 DWG. FILE 513196M1 SHUT', B.O.J. 12' 2' -! oF3 SHEETS ----r---yT T 1 r-1� �\ ,_ LJ I i „ -'1 .�.. 1 �I i \ I _4: , .< >I / " , I �• (>I i L__ --J NOTES: 1.TO ERL'S BEST JUDGEMENT, WE CALCULATE TWELVE (12) NECESSARY PENETRATIONS THROUGH STRUCTURAL I - BEAMS IN CEILING ABOVE THE OPEN OFFICE ON THE MAIN FLOOR; - 6 PENETRATIONS THROUGH BEAM ON GRID LINEA - 4 PENETRATIONS THROUGH BEAM ON GRID LINE B - 2 PENETRATIONS THROUGH BEAM ON GRID LINE C 2. ALL PENETRATIONS THROUGH STRUCTURAL LBEAMS BE 10"O IN SIZE IN ACCORDANCE WITH ERL PLANS. 3. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE ADDITIONAL AIR CIRCULATION. TEE SPECIFIED DIFFUSERS WILL BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. REST OF OFFICES DIFFUSERS ARE MCD FOR SUPPLY, 50F FOR RETURN. NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY • ARE AND SHALL REMAIN THE PROPERTY.OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERVISE USED WITHOUT THE PRIOR WRITTEN CONSENT DF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS DR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. O F===1 F=== r---- --.�. 1 1 F= -- 44"x8" r- JBLM Ha cn h===i L== -J .6===J L===A 04/16/13 4/30/13 GEN. REV. GEN. REV. DRAWING DATE: 04/10/13 DWG.: FILE: 513196M1 RECEIVED CITY OF TUKWILA MAY 0 6 2013 PERMIT CENTER SHEETS Nt1T. PUBLISHED. AU. RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED AND SHALL REMAIN l PRIPRYOF EVE- RGREEN REFRIGERATIOi INC. FM PART THERED' SHALL BE REPRODUCED, CIPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLE, PUB- WRITTEN CONSENT OF AND OR OTHERWISE D APPR ED WITHOUT TO EVERGREEN REFRIG_RATION•INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. NOTES: 1. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE ADDITIONAL AIR CIRCULATION. THE SPECIFIED DIFFUSERS WILL BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. REST OF OFFICES DIFFUSERS ARE. MCD FOR SUPPLY, 50F FOR RETURN. a0 1-- TT T I I I r �I 1 LJI -\ � I I,. 1 v >1 .1 <\ >I\ v L ---J RETURN GRILLE TO BE WALL MOUNTED (VERSUS TYPICAL CEILING MOUNTED GRILLES) GRILLE TO BE LOCATED PER ERL DESIGN, HIGH ON WALL NEXT TO CEILING.' -u L. -L -I LJ LJ .J L-, LJ L -J • f===.9 F===9. t 1 -1, I r 1 1 1 . 1 1 1 4, 1 SERVE RTU -3 1'VALL pRILLE 20"x2 I T!-IERM. SERVE RTU -4 I I I L _J . L 1111111111 -THEKM.St REVISIONS — JQ 4117171 IP mimmum maw aulammewirtwastinisw7 nom/ anis 41mum, Te,��li►,tea 0111.11 1� 00 ' "tire rawmpapa 04/16/13 GEN. REV. PR( VIDE BYERL INSTALL BY OTHERS) DRAWING DATE: 04/1 0/1 3 DWG. FILE: RECEIVED CITY OF TUKWI MAY 0 6 2013 PERMIT CENTE NOTES 1.TO ERL'S BEST, JUDGEMENT, WE CALCULATE TWELVE (12).. NECESSARY PENETRATIONS THROUGH STRUCTURAL Z- BEAMS IN CEILING. ABOVE THE OPEN OFFICE ON THE MAIN FLOOR; • - 6 PENETRATIONS THROUGH BEAM ON GRID LINE A - 4 PENETRATIONS THROUGH BEAM ON GRID LINE B 2 PENETRATIONS THROUGH BEAM ON GRID LINE C 2, ALL PENETRATIONS THROUGH STRUCTURALT--BEAMS BE 10"0 IN SIZE IN ACCORDANCE WITH ERL PLANS. • 3. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION ..' OF. LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS M11ILL PROVIDE ADDITIONAL AIR CIRCULATION. THE SPEC)PIED DIFFUSERS WILLBE TITUS HIGH PERFORMANCE TMS CEILING.. DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIRDISPERSION. REST OF OFFICES DIFFUSERS ARE MCD FOR. SUPPLY, 59F FOR RETURN. • NOT In/BUSIED. ALL. RIGHTS RESERVED. THE • DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS' AND ARRANGEMENTS REPRESENTED T EREBY_ .. ARE AND SHALL REMAIN THE PROPERTY OF•EVE RGREEN REFRIGERATION INC. NO. PART THEREIN. SHALL BE REPRODUCED, CDPIED, ADAPTED,.DISC- LOSED OR DISTRIBUTED .10 OTHERS, SOLD, PUB LISFB D OR OTHERVISE USED WITHOUT THE PRIOR VRITTEN CONSENT OF AND•APPRDPRIATE CUID'EN- SATION TO EVERGREEN REFRIGERATMNN INC. VISUAL CONTACT WITH INC ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CCNJCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS 00 . •ON L 13"~it6i.CE , APPROVED .MAY 02 2013 ��—!gym• —��� ®al 1%IBai/uE a IMEMMIIII1dItF� 1d 1 111 �-��� _ !' 1 1'1 : u31� r r 1 REVISIONS 0 1N JOB SHEET::' NOT PUBLISHED. ALL RIGHTS RI SERVED..mE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS: AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC LOSED 13R DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT.THE PRIOR' WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. KEY; NOTES: ®RETURN':GRILLE TO BE WALL MOUNTED (VERSUS TIPIpAL CEILING MOUNTED GRILLES) GRILLE TOE:LOCATED PER ERL DESIGN,;. HIGH ON WALL NEXT TO CEILING. NOTES: 1. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE . ADDITIONAL AIR CIRCULATION. THE SPECIFIED DIFFUSERS WILL BE TITUS. HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. - REST OF OFFICES DIFFUSERS ARE MCD FOR SUPPLY, 50F FOR RETURN. yr ! ...„ IlrIrm't���-_i I I % c3)iii 1 iRVE RTU -3 VE RTU - T11.041111.1111. aINT)mirril 'AI NI Ir.- � ®1111111 m ® Ems 0= 011111=I AI 00 !Wi alts`l r-=-TwIwwI.