Loading...
HomeMy WebLinkAboutPermit PG13-061 - SANSACO - ALTERATIONSANSACO 5920 S 180 ST PG13-061 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Project Name: SANSACO PLUMBING/GAS PIPING PERMIT Permit Number: PG13-061 Issue Date: 05/24/2013 Permit Expires On: 11/20/2013 Owner: Name: BOEING OREGON MASABI TRUST Address: 1325 4TH AVE SUITE 1940 , SEATTLE WA 98101 Contact Person: Name: BUD KLOSTERMAN Address: 8706 S 222 ST , KENT WA 98031 Email: BUD@STATEMECH.NET Contractor: Name: STATE MECHANICAL COMPANY Address: 600 INDUSTRY DR 8 , TUKWILA WA 98188 Contractor License No: STATEMC 141 C7 Phone: 206-575-7527 Phone: (206)575-7527 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: INSTALL 3 WATER CLOSETS, 2 LAVATORIES, 1 URINAL, 2 FLOOR DRAINS, 1 WATER HEATER AND ALL RELATED PIPING, 1 SINK AND 1 DRINKING FOUNTAIN. Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $9,650.00 Uniform Plumbing Code Edition: 2009 $274.31 International Fuel Gas Code Edition: 2009 I hereby certify that I have read and ex governing this work will be complied e h, w J this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. Date: M(4t The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: •gN YVV STO r7 I( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. r t' INC4 Drin4erl• _11 11 • i PERMIT CONDITIONS Permit No. PG 13-061 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG13-061 Printed: 05-24-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukwi I aW A. gov Plumbing/Gas Permit No. P6 6-66 Project No. Date Application Accepted: 0 40 cf f i 3 Date Application Expires: /0 /D-6/43 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 592_0 1.g01 Tenant Name: S A %S S ICO PROPERTY OWNER Name: g 14C\ 0 ka:10 k/ ()/1 {1 I "Te -U5 7 Address: )315' y F In m� CV I h 11 ei o �7w City: State: r Zip ,(0 ( �� CONTACT PERSON — person receiving all project communication Name: *L -) L,13 1(-.C...c) STErZin ( M Address: .--70 Z22-1Jt .S?` City: K_ - v - State:W 4 Zip: q j3 / Phone:` 06, _5--5 ,152,--7 FaxZd6 575- Z5Z9, Email: LilQ. S gfeje- YY\eL ' (ke-4- King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ®. Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: .67....717.6.. MC—c 1/ t‘ (CR c Address: ...-70 co 5 222 pp 5�. City: Iel\i ` State: j 19 Zips 0 3 l Phone:7_00_515_752,1 Fa'tZ1x,,-5`7v_:..7SZ-oi Contr Reg No.:s MC/y/ C'E xp Date: Gv1 sl 3 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 12 5d Scope of Work (please provide detailed information): 5tA Wis ATeL C( Urc-2 LA 0110Z -k. €.S U EL` (..1 Pr / 2 F-cxort- X 12-R(1,LS i I C Ick 1A0.%-}c,rs c9. a /( / I p.rel(J ) 1 s'tV\K- C) vtC (D (\1N~t-P,<v Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer H\Applications\Forms-Applications On Cine\2011 Applications \Plumbing Permit Application Revised g-9-1 I .docs P.A.,P 1 nf'7 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Z Shower, single head trap 2 - Sinks ... Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Z Lavatory 2 - Urinal ... Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Z Wash fountain Water closet ... Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Z Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R AUTH ENT: Signature: �j/ {//V Print Name: E EJVi 6"7-014/14 Mailing Address: ?1O$ .S L2 't H:\Applications\Forms-Applications On Line\201 I Applications\Plumbing Permit Application Revised 8-9-11 .docx Revised: August 2011 Day Telephone: City Date:4/ IS A 9703( State Zip Page 2 of 2 City of Tukwila Department of Commrmity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.esov Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: Applicant: SANSACO RECEIPT Permit Number: PG13-061 Status: PENDING Applied Date: 04/24/2013 Issue Date: Receipt No.: R13-01420 Initials: User ID: LAW 1632 Payment Amount: $274.31 Payment Date: 04/24/2013 04:34 PM Balance: $0.00 Payee: STATE MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 514264 ACCOUNT ITEM LIST: Description 274.31 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 54.86 000.322.103.00.00 219.45 Total: $274.31 Printed: 04-24-2013 i City of Tukwila 1 Department of Cosninunity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: Applicant: SANSACO RECEIPT Permit Number: PG 13-061 Status: PENDING Applied Date: 04/24/2013 Issue Date: Receipt No.: R13-01415 Initials: User ID: LAW 1632 Payment Amount: $-54.86 Payment Date: 04/24/2013 04:34 PM Balance: $0.00 Payee: PAID FULL PERMIT FEE TRANSACTION LIST: Type Method Descriptio Amount Payment Void Authorization No. 514264 ACCOUNT ITEM LIST: Description -54.86 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 -54.86 Total: $-54.86 rinr.• Parcint fl Printed: 04-24-2013 01) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 3523049105 Address: 5920 S 180 ST TUKW Suite No: Applicant: SANSACO RECEIPT Permit Number: PG 13-061 Status: PENDING Applied Date: 04/24/2013 Issue Date: Receipt No.: R13-01415 Payment Amount: $54.86 Initials: LAW Payment Date: 04/24/2013 01:47 PM User ID: 1632 Balance: $219.45 Payee: STATE MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 514264 ACCOUNT ITEM LIST: Description 54.86 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 54.86 Total: $54.86 Orin+ .,1• nd_9d_9n14 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Project: i .,�CnV\SCIC 0 Type of Inspection: \v11.1 j i Address: c) 0 s 19)r) --}- Date Called: j_ it -- 1 Special Instructions: Date Wanted:. 1 1,.. 1 t - 1 ,;), a.m. p.m. Requester: `` , ' Phone No: - Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: taviAD i / E Inspector: �./ r,..4,./.., rib) Date: REINSPECTION FEE REQUIRED. Prior to next inspection fee must be paid at 6300 SouthcenterBlvd., Suite 100. Call to schedule reinspection.: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION •6300 Southcenter Blvd., #100, Tukwila. WA 98188 `iL (206) 431-3670 Permit Inspection Request Line (206) 431-2451 V P6 (3-061 Pro'ect: T of sp ctr ijon:.� , J ( Ad`d_,LC55:� � � � '��_,_. Date Called: Special Instructions: Date Wanted= //a.m. —+.�_ + J m. ( p. Requester: �-^�' Phonecc-sig- 0038` \'‘V, A\roved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 76 ( ns• ct'r: Date: 11 -7-- NSPECTION FEE REQUIRED. Prior to next inspection, fee must be aid at 6300 Southcent1Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ". 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 PG(3-0Cof ProjeType Typeof Inspection: r v.�.0 W of Address• lDate S -2'.e) I O ,S`r - Called: Special Instructions: 3 v1/ _ '2, LA-.. I or, elA- L .. 2 F Q IT 1 S'" Date Wanted ' -2 �'"�3 rc.p.m. p.m. Requester: tit/ A -Y 144 - 1 F.P Ja7-4-1 o e No: To _ i _ 4 31 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: A II Ins�ecto�r ���� y Dat - ( � ti ri "—I REINSPECTION FEE REQUIRED. Prier to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. DF FD WC 3"VTR SINK TO 2ND FLOOR 3"V �1I 3"W I UR LIAV LAV 2"W WC WC FD TIE INTO EX 3" WASTE SASCO WASTE AND VENT RISER DIAGRAM *CLEANOUTS PER CODE pG 13O(oI 11410% ps REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2013 City of Tukwila BUILDING DIVISION RECEIVED APR 2 5 201 TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA APR 2 4 2013 PERMIT CENTER 1Y2"CW TIE INTO EX 2 "CW "vEWH SINK I 1y2„ CW II 3/4"HW it FD CW TO(k TRAP ,PRIMER WC SASCO HOT AND COLD RISER DIAGRAM UR LAV DF LAV WC WC FD CW TO TRAP PRIMER RECEIVED CITY OF TUKWILA APR 2 4 2013 PERMIT CENTER May 1, 2013 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Bud Klosterman State Mechanical Company 8706 S 222 St Kent, WA 98031 RE: Correction Letter #1 Plumbing/Gas Piping Permit Application Number PG13-061 Sansaco — 5920 S 180 St Dear Mr. Klosterman, This letter is to inform you of corrections that must be addressed before your plumbing/gas piping permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Public Works Department has no comments. Building Department: Allen Johannessen at 206-433-7163 if you have any questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431-3670. Sincerely, b=tg Bill Rambo Permit Technician encl File: PG13-061 W:IPermit Center\Correction Letters120131PG13-061 Correction Letter #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: April 30, 2013 Project Name: Sansaco Permit #: PG13-061 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the sane size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. The Building permit shall require some changes to the plan to include the number of bathroom fixtures. Show the bathrooms consistent with the changes on the building permit. (See building review memo #6 below) 6. Number of bathroom fixtures for the display and office area shall only require two for each bathroom (200 sq. ft. per occupant = 2 ea.). However the storage area shall require one additional fixture (5000 sq. ft. per occupant = 1 ea.). Therefore one additional toilet and sink fixture shall be required for the two bathrooms. Show the additional fixtures per bathroom. (IBC Chapter 29 Washington State Amendments) Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. Page 2 of 2 TOC OOH NN PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-0$1 DATE: 05/23/13 PROJECT NAME: SANSACO SITE ADDRESS: 5920 S 180 ST Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: FrAi uiilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05/28/13 Complete 1Z Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route ❑ Structural Review Required ❑ No further Review Required I REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/25/13 Approved ❑ Approved with Conditions tYS Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: ;:E!4iT COM CG.•\ PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-061 DATE: 04-24-13 PROJECT NAME: SANSACO SITE ADDRESS: 5920 S 180 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued EPATMENT, : IIQVA Building Division Worlts 3 Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: Complete Comments: Incomplete 04-25-13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route 'KtStructural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-23-13 Not Approved (attach comments) M DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: May 23, 2013 Plan Check/Permit Number: PG 13-061 ❑ Response to Incomplete Letter # ® Response to Correction Letter # C ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Sansaco Project Address: 5920 S 180 St " C IVED ,Kwrla MAY 232013 PERMIT cENTra Steve Carney (206) 575-7527 Contact Person: Phone Number: Summary of Revision: As per conversation with Allen Johannessen the issue has been resolved. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit ente by: rKEntered in Permits Plus on 25 1 3 \applications\fonns-applications on line\revision submittal Created: 8-13-2004 Revised: 1-2009 Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company STATE MECHANICAL COMPANY 2065757527 8706 S 222Nd St Kent WA 98031 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600611697 Active STATEMC141C7 Construction Contractor 2/27/1986 9/1/2013 Plumbing Unused License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DESIGM•110NQDESIGN MECHANICAL Construction Contractor Boiler/Steam Fit/Proc Piping Plumbing 8/18/1989 8/17/1993 Archived RXHCO"121NARXH COMPANY Construction Contractor plumbin g Boiler/Steam Fit/Proc Piping 8/1/1988 7/27/1999 Archived GERRICI163B3 GERRIK COMPANY INC Construction Contractor General Unused 1/23/1984 1/9/1991 Archived Business Owner Information Name Role Effective Date Expiration Date PLATZ, GERRICK D Chief Executive Officer 01/01/1980 Amount LYNCH, JOHN MICHAEL Chief Executive Officer 12/18/2012 GL166026 DEWITT, RALPH E 06/02/2013 01/01/1980 12/18/2012 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS Et SURETY CO 200686359 07/27/2001 Until Cancelled $6,000.00 08/14/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 23 Colony National Ins Co GL166026 06/02/2012 06/02/2013 $1,000,000.0006/01/2012 22 Colony Ins Co GL1650262 06/02/2011 06/02/2012 $2,000,000.00 06/02/2011 21 COLONY INS CO GL1650262 06/02/2010 06/02/2011 $1,000,000.0009/16/2010 20 COLONY INS CO GL1650261 06/02/2008 06/02/2011 $1,000,000.00 05/06/2010 19 FIRST MERCURY INS CO FMFL001801 06/02/2006 06/02/2008 $1,000,000.00 05/09/2007 18 NORTH AMERICAN CAPACITY PNG100046600 06/02/2006 06/02/2007 $1,000,000.00 05/25/2006 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httnc. //fortress _wa_ gov/1 ni/bbin/Print.asnx 05/24/2013 4/22/2013 La a 1- 1. ALL MAI tet 1ALJ ANL) WUKKMANSHIt' GUM UKM IU WASHING I UN SLATE WAC 51-50 ACCESSIBILITY REGULATIONS, THE 2009 INTERNATIONAL BUILDING, CODE (IBC) MECHANICAL, AND ELECTRICAL CODES AND LOCAL CODES OR MOST RECENTLY ADOPTED EDITION OR ADOPTED AMENDMENTS TO THE WASHINGTON STATE ENERGY CODE. 2. THE CONTRACTOR SHALL OBTAIN DESIGN/BUILD PERMITS AND REQUIRED APPROVALS. 3. TYPICAL DETAILS SHALL APPLY WHERE NO SPECIFIC DETAILS ARE GIVEN. 4. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS PRIOR TO CONSTRUCTION. 5. ALL DIMENSIONS ARE TO TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, ELEVATIONS, SECTIONS, AND DETAILS. 6. ALL EXIT DOORS TO BE OPERABLE FROM INSIDE BUILDING WITHOUT KEYS OR SPECIAL KNOWLEDGE. 7. OWNER AND CONTRACTOR TO DETERMINE EXTENT OF TENANT IMPROVEMENT WORK AS RELATED TO SHELL CONSTRUCTION WHERE NOT SPECIFICALLY DEFINED ON THE DRAWINGS. 8. WALLS ARE TO BE FIRESTOPPED PER IBC SECTION 717. 9. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 1110. PROVIDE (1) 2A:10B:C FIRE EXTINGUISHER PER 3,000 S.F. OR 75' TRAVEL DISTANCE. EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 POUNDS SHALL BE INSTALLED SO THAT THE TOP OF THE EXTINGUISHER IS NOT MORE THAN 54" ABOVE THE FLOOR, PER IBC 1109.13 & 2002 NFPA #10, 1.5.10. 10. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR SHALL BE TREATED TO BE FIRE RESISTIVE, TO MEET IBC CHAPTER 6 REQUIREMENTS. DELIVER CERTIFICATE TO THE LOCAL FIRE DEPARTMENT. 11. ALL INTERIOR WALLS ATTACHED TO SUSPENDED CEILING SYSTEMS TO MEET THE REQUIREMENTS OF IBC SECTION 1604 & 1607. 12. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDINGS WHERE APPLICABLE. 13. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS ARE TO BE FIRE STOPPED PER IBC SECTION 712. 14. PENETRATIONS IN FLOORS AND CEILINGS REQUIRING PROTECTED OPENINGS ARE TO BE FIRESTOPPED PER IBC SECTION 712. 15. WOOD USED IN PERMANENT PARTITIONS OF NONCOMBUSTIE3LE CONSTRUCTION SHALL HAVE FIRE RETARDANT TREATMENT PER IBC SECTION 603.1. 16. ALL EQUALS TO BE SUBMITTED TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. 17. BID DESIGN WORK TO BE REVIEWED BY ARCHITECT PRIOR TO CONSTRUCTION. 18. SUI3MIT AS -BUILT DRAWINGS FOR GENERAL CONSTRUCTION, PLUMBING, MECHANICAL, ELECTRICAL AND SPRINKLER TO ARCHITECT AT PROJECT CLOSE-OUT. 19. EXIT CORRIDORS TO BE MAINTAINED DURING CONSTRUCTION OF EACH PHASE. 20. INSTALL SPRINKLERS ACCORDING TO DRAWINGS APPROVED BY LOCAL FIRE MARSHAL. 21. EXITS SHALL BE ILLUMINATED ANY TIME THE BUILDING IS OCCUPIED, WITH LIGHT HAVING INTENSITY OF NOT LESS THAN 1 FOOT --CANDLE AT FLOOR LEVEL. FIXTURES REQUIRED FOR EXIT ILLUMINATION SHALL BE SUPPLIED FROM SEPARATE SOURCES OF POWER AND BE PROVIDED WITH AN EMERGENCY SYSTEM PER IBC SECTION 1006. EMERGENCY SYSTEMS SHALL BE SUPPLIED FROM STORAGE BATTERIES OR AN ON SITE GENERATOR IN ACCORDANCE WITH IBC SECTION 2702. 22. ELECTRIC RESISTANCE HEAT IS NOT ALLOWED. 23. DIMENSIONS TO AND OF ELECTRICAL AND TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 24. DIMENSIONS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE *DIMENSIONS OF NEW WORK TO FACE OF STUD *DIMENSIONS OF EXISTING WORK TO FACE OF FINISH *DIMENSIONS OF DEMO WORK TO FACE OF FINISH GENERAL NOTES 10 STAINLESS STEEL E 0 0> z CI1 ict oar X42" CD <1 44 ,13 2' X 4' LIGHT FIXTURE 2' X 2' LIGHT FIXTURE TRACK LIGHTING RECESSED DOWNLIGHT RECESSED DIRECTIONAL DOWNLIGHT PENDANT LIGHT STRIP LIGHTING CEILING DIFFUSER EXHAUST REGISTER fa EF EXHAUST FAN SPRINKLER (HEAD EXIT SIGN DUPLEX OUTLET AT 15" A.F.F FOURPLEX OUTLET AT 15" A.F.F DEDICATED DUPLEX OUTLET AT 15" A.F.F DEDICATED FOURPLEX OUTLET AT 15" A.F.F FLOOR MOUNTED OUTLET DUPLEX OUTLET AT 42" A.F.F COMPUTER\DATA OUTLET AT 15" A.F.F FLOOR MOUNTED COMPUTER\DATA OUTLET DATA/PHONE OUTLET DATA OUTLET TELEPHONE AT 15" A.F.F FLOOR MOUNTED TELEPHONE LIGHT TOGGLE SWITCH AT 42" A.F.F 3 -WAY LIGHT TOGGLE SWITCH TYPICAL SPACING FOR ADJ. WALL OUTLETS R RELOCATED N NEW E EXISTING NOTE: THE ABOVE SYMBOLS ARE USED ON 'T' SHEETS, REF. CONSULTANTS SYMBOLS FOR THEIR RESPECTIVE DWGS. THE FOLLOWING BID DESIGNS ARE REQUIRED FOR PERMITS AND APPROVALS FROM THE BUILDING OFFICIAL OR THE AUTHORITY HAVING JURISDICTION. NO WORK SHALL BE STARTED PRIOR TO THE APPROVAL OF THE BUILDING OFFICIAL OR THE AUTHORITY HAVING JURISDICTION. COPIES SHALL BE FORWARDED TO THE ARCHITECT AND COORDINATION OF THE DISCIPLINES SHALL BE THROUGH THE GENERAL CONTRACTOR. FLOOR SEPARATE PERMIT .aalNFR,ZpHONE= 1. ELECTRICAL WORK & LIGHTING DESIGN 2. HEATING VENTILATING & AIR CONDITIONING DESIGN 3. PLUMI3ING DESIGN 4. FIRE WATER SPRINKLER SYSTEM DESIGN 5. FIRE ALARM SYSTEM DESIGN TO BE SELECTED O 0 101 SECTION OR DETAIL NUMBERS DETAIL - SECTION OR TARGET DRAWING WHERE SECTION OR DETAIL IS DRAWN PARTIAL OR FULL SECTION WALL OR DETAIL SECTIONS INTERIOR FINISHED WALL- ELEVATIONS S DOTE DOOR NUMBER e“1111••10 EXISTING DOOR .EXISTING RELITE GRID„ LIMES - COLUMN ROOM NUMBER ME EXISTING WALL TO REMAIN 7 = = C EXISTING WALL TO B REMOVED S 180TH ST STUD & DRYIALLat SOUND BAIT INSULATION 362S125-18 © 2'-O" O.C. WITH 3 1/2" SOUND BLANKET INSULATION & 5/8" GWB EACH SIDE UP TO HEIGHTS NOTED ON PLANS STUD& Dom' SOUNDBATTINSULATION 600S125-18 '© 2'-O" O.C. WITH 5 1/2" SOUND BLANKET INSULATION & 5/8" GWB EACH SIDE UP TO HEIGHTS NOTED ON PLANS PROJECT SYMBOLS A.C.T. A.F.F. ALUM. ASPH. BD. BLDG. BLK'G BM. B.U.R. CLG. CLSR. COL CONC. CONST. CONT. ACOUSTICAL CEILING TILE ABOVE FINISHED FLOOR ALUMINUM ASPHALT ANOD. ANODIZED BOARD BUILDING BLOCKING BEAM BUILT UP ROOFING CENTER LINE CEILING CLOSER COLUMN CONCRETE CONSTRUCTION CONTINUOUS D/F. DRINKING FOUNTAIN D1A.(41) DIAMETER DIM. DIMENSION DR DOOR DET. DETAIL D.S. DOWNSPOUT DTI:. DRAWING EXIH FH EXHAUST FAN E.IF.S. EXT. INSUL. FINISH SYSTEM ELEC. ELECTRICAL ELEV. ELEVATION ENG. ENGINEER EQ EQUAL EQUIP. EQUIPMENT E.W.C. ELECTRIC WATER COOLER EXIST. EXISTING EXP. EXPANSION EXT. EXTERIOR F4F. FACTORY FINISH F.AiR, FLOOR AREA RATIO F.D. FLOOR DRAIN F.P.C. FIRE DEPARTMENT CONNECTION FON. FOUNDATION F.P. FIRE EXTINGUISHER F.A.C. FIRE EXTINGUISHER CABINET F.B, FINISHED FLOOR FA. FIRE HYDRANT FIN. FINISH FL. FLASHING FLR. FLOOR F,d.C., FACE OF CONCRETE F.D.F. FACE OF FRAMING F.R.P. FIBER REINFORCED PLASTIC FT. j FEET FTG. FOOTING GA. GAUGE GALV. GALVANIZED G.F;,C.,I. CROUND FAULT CIRCUIT INTERRUPTER GL GLASS GLU-LAMINATED BEAM G.W.B. GYPSUM WALL BOARD GYP. GYPSUM H.B. HOSE BIB HCP. HANDICAPED HDWR, HARDWARE HORIZ. HORIZONTAL H.P. HIGH POINT H.P.S. HIGH PRESSURE SODIUM HR.' HOUR HT. HEIGHT MIER AGENT TO BE SELECTED TO BE SELECTED TO BE SELECTED TO BE SELECTED BOEING AEROSPACE COMPANY S 212TH ST DRINKING FOUNTAINS 11 SEPARATE SUBMITTAL P FIIIIIMMIN aliMMIR MIONNIN cs4 ▪ 1111.111.1 MI 111•MIIMIN. MI 11.1 10111•11111111 NM MN co MO ON WI 111110,1•0 11111 1 Ili 27 1 111,. re)a to 0N to O ▪ 1- CO 0= CL w Z©E E J , 1 Q= " 1 _ .'j i 0 I i i EXIT EXIT FILE COPY Pernik Na PC1I19_ 1 Plan review appwoval Is subject to farors and = Approval of construction documents does not authorize the, violation of any adopted code or ordinance. Receipt /py City OfTukwila BUILDING DIVISION 80152'23'W 554.62' • • • N M N O O W J ✓ 1-- W EXIT -_- O 0 SI - - -1 a w iJ AREA OF WORK SEPARATE PERMIT REQUIRED FOR: IIMechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION ri EXIT II HWILILIIII III II ILII H 11 11 II 11111111 II II MI ILII II III III II ILII 11 11 11 11 11111111 II II 1111 ILII II III 111 II 1111 II II -------- - 11•1•1111“ - 111111.1 - - --� - - - - - - - - - - - -h--- - - MMIIMINIMI - - N0151'39'E 553.89' 10 - - '---- 9 9 9 c 10( c c •• 1•1111111=11 IN I= =Milli MI I•1 1•11•11141111111111 •1111111111111 • 1 1 imod 1 1 10 C c 0, C SITE PLAN NORTH CODE REFERENCE JURISDICTION LAND USE ZONE SEISMIC ZONE CONSTRUCTION TYPE OCCUPANCY TYPE OCCUPANCY LOAD NUMBER OF FLOORS SITE AREA GROSS BUILDING AREA • FIRST FLOOR • MEZZANINE PARKING SUMMARY (EXISTING) • STANDARD (EXISTING) • COMPACT (EXISTING) = • ACCESSIBLE (EXISTING) = NORTH VICINITY MAP r6 2009 INTERNATIONAL BUILDING ZONE (IBC) WITH WASHINGTON STATE AMENDMENTS CHAPTER 51-50 WAC TUKWILA, WASHINGTON (TUC) TUKWILA, URBAN CENTER CLASS D III -B SPRINKLERED 51 WAREHOUSE, M SHOWROOM, B OFFICE 635 1 + MEZZANINE ±138,473 S.F. 3.18 ACRES ±57,432 S.F. ± 2,909 S.F. BULK RETAIL, OFFICE, WAREHOUSE USE DESCRIPTION OF WORK: IMPROVE EXISTING MEZZANINE FOR OFFICE DISPLAY USE, ADD BREAKROOM, OFFICE, 2 STAIRS AND GUARD RAILS AND INSTALL RESTROOMS AT 1ST FLOOR. ADD GWB © PERIMETER WALLS AND INSULATE FOR FUTURE OFFICE. INSULATE WALLS AND CEILINGS AT CONDITIONED SPACES. CONDITIONED SPACES © RESTROOM, BREAKROOM, AND OFFICE. 109 STALLS 74 STALLS 30 STALLS 5 STALLS PLUS DELIVERY/PICKUP AREAS INSUL. INSULATION INT. INTERIOR JT. JOINT JST. JOIST LAV. LAVATORY MAIL. MATERIAL MAX. MAXIMUM MECH. MECHANICAL MFR. MANUFACTURER MIN. MINIMUM MIX. MIXTURE MTL. METAL N.I.C. NOT IN CONTRACT NO (#) NUMBER N.T.S. NOT TO SCALE 0.C. ON CENTER OFF. OFFICE 0,V.L. OVERFLOW LEADER 0.P. OPERABLE OPEN. OPENING PLATE P.L. PROPERTY LINE P'LAM PLASTIC LAMINATE PLYWD. PLYWOOD PNL. PANEL P&P PATCH AND PAINT PTN, PARTITION R.B. RUBBER BASE R.D. ROOF DRAIN REC. RECESSED REPT. RECEPTACLE REP. REFLECTED REINF. REINFORCING R.L. RAIN LEADER RM. ROOM SDG. SIDING SHT. SHEET S.F. SQUARE FEET S.O.G. SLAB ON GRADE SPEC. SPECIFICATION STD, STANDARD STL. STEEL STRUCT. STRUCTURAL ST&VN STAIN AND VARNISH T. TELE. TEMP. T.I. T.O.P. T.W.C. TYP. U.O.N. V.C.T. VENT. VERT. V.W.C. W.C. W.COV. WD. WDW. W.H. W.R. TOILET TELEPHONE TEMPERED TENANT IMPROVEMANT TOP OF PARAPET TACKABLE WALL COVERING TYPICAL UNLESS OTHERWISE NOTED VINYL, COMPOSITION TILE VENTILATE VERTICAL VINYL WALL COVERING WATER CLOSET WALL COVERING WOOD WINDOW WATER HEATER WATER RESISTANT ABBREVIATIONS SANSACO 5950 S 180TH STREET, TUKWILA, WASHINGTON 98188 (206) 575-0811 BOEING OREGON MASABI TRUST' 1325 4TH AVE, SUITE 1940 SEATLE, WASHINGTON 98101 FRANK AGOSTINO CORPORATE REAL ESTATE (206) 447-0444 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 3 2013 City of u iia BUILDING ISION LPN ARCHITECTURE AND PLANNING 3011 80TH AVE. S.E. 7-0 MERCER ISLAND, WASHINGTON 98040 (206) 230-6648 FAX (206) 230-6647 ROYCE BERG CONTRACTOR GATEWAY CONSTRUCTION SERVICES, INC. 5602 2ND AVE. S. SEATTLE, WASHINGTON 98108 (206) 621-9111 FAX (206) 621-9113 BILL FOSTER CONSULTANTS 2 REVISIONS -t No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. CODE DATA TAX ACCOUNT NO. 3523049105 W 250 FT MEAS AT R f A TO W LN OF FOLG DESC TR POR NW 1/4 OF NE 1/4 BEG NE COR SD SUBD TH S 1-51-39 W 1003.75 FT TH N 87-55-02 W 30 FT TO W MGN ANDOVER PARK WEST & TPOB TH CONTG N 87-55-02 W 270 FT TH N 1-51-39 E 272.50 FT TH N 87-55-02 W 440.70 FT TH S 1-51-39 W 553.89 FT TO A LN 36 FT N OF C/L OF S 180TH ST TH S 87-50-09 E 685.17 FT TH ALG CURVE TO LFT CENTER OF WCH BEARS W 27-26-23 W RAD 50 FT DISC 52.97 FT THRU C/A OF 60-41-58 TO W MGN OF ANDOVER PARK WEST TH N 1--51-39 E 238.66 FT TO TPOB RECEIVED APR 2 5 2013 TUKVV1Lr, PUBLIC WORKS LEGAL DESCRIPTION aI T-1 T-2 T-4 PROJECT DATA, VICINITY MAP, CODE DATA & SITE PLAN --- OVERALL PLAN & EXITING, 1ST FLOOR & MEZZANINE FLOOR PLANS & CEILING PLANS DETAILS, SECTIONS i3L ELEVATIONS - DETAILS, SECTIONS & ELEVATIONS RECEIVED CITY OF TUKWILA APR 2.4 2013 PERMIT CENTER oil SHEET INDEX O Li. 1 CC CC) Cs LiJ F- LU 0 CC z CO loct imw _ 4C0 :112j CM he CD ME - ROYCE A MEG, PRMVOIPAL 3011 80TH AVE SOUTHEAST MERCER ISLAND, WA. 98040 (206)2300.6648 FAX 2304447 DATE 4-12-13 4-18-13 4-19-13 4-22-13 "DATA CONTAINED ON THESE PLANS OR ELECTRONIC FILES ARE PART OF THE CONSULTANT'S INSTRUMENTS OF SERMICE AND SHALL REMAIN THE PROPERTY OF THE CONSULTANT. SUCH DATA SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSTRUCTION OF THE REFERENCED PROJECT. ANY OTHER USE, REUSE OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR. WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT.' File: 13009/T-1.dwg CHECK: RAB 4/22/2013 4114 PM ci H --IM1111111•111111111 EXISTING 4x8 SMOKE VENT - •--I-- _ ®I 110 I 1 EXISTINGEXPOSED_ ROOF STRUCTURE SII II II II1I 11 lid iiII.II' (tr nu' 1 mini C�) r. I F Ins B I .tai I .. I ... 1 1. G1) !IU I.. I 1•r I INS_ 1 -NU 1 op' tl mai 11 r. 11 no SUSPENDED CEILING,+— SEE DETAILS -11-,-1-2,i -- 13 15 &i Z11111 - I I _ I o I e I Mil .. I Inn I I I. I -- -IFI•—.Fi 1.-1111M-1-1-1•11. 1 = -=- 24__ •B11 II II 1 I MI I I MI I I r. 1 Ws i. 11111111 SCHEMATIC LIGHTING CONTROLS REQUIRED PER SECTION 1513 OF THE NREC., DAYLIGHT ZONES 1 AND 2 TO BE SWITCHED SEPARATELY FROM GENERAL LIGHTING. OCCUPANCY SENSORS REQUIRED IN ALL OFFICES, CLASSROOMS, CONFERENCE ROOMS, WAREHOUSES AND STORAGE RC OMS. AUTOMATIC SHUT-OFF -CONTROLS ARE REQUIRED FOR ALL LIGHTING INCLUDING TASK LIGHTING ON DEMOUNTABLE PARTITIONS. EITHER OCCUPANCY SENSORS OR TIME SWITCHES ARE REQUIRED. EXISTING LIGHTING, RELOCATED LIGHTS SCHEMATIC PLAN, SEE: BID DESIGN ELECTRICAL ELECTRICAL BID DESIGN WITH SEPARATE PERMIT. * OC = OCCUPANCY SENSORS AT NEW OFFICE AND CONFERENCE E EXIST NG R RELOCATED N NEW NORTH FIELD VERIFY DIMENSIONS WITH SPRINKLER RISER LOCATION—r- 5'-2" FULL HIGH WALL STAIR SEE----' DETAIL. 8/T-3 /_� 4 pe —r, oF 7 Q— 11i II II II �J -12!_11 4� >-ALIGN 11111 il■i II II MI • -10' HIGH WALLS -1 .fi WALL ±42" r.m] LI) 3'x4" WINDOW © 36" AFF — CENTERED IN WALL In •li■II II III i OPEN OFFICE ±2,9C)9 S.F.. NET AREA SEALED PLYWOOD FLOORING IRE —FLUSH MOUNT 4-P LEX TYP. (4 LOCATIONS) 1 4'-6" 7.= GFlC G , BREAKROOM C20] VCT RS 0.5)— --- JL.417.= -1L-i 1c HIGH WALL RS -- 10' HIGH WALLS 6� T- jsity ALIGN FULL HIGH WALLS ----- STAIR SEE DETAIL 8/T--3 SIM DN UP 12 T-3 T13� SIM [�I ALIGN--7 OPEN OFFICE E?oz VCT FULL HIGH WALL--\ 12'-8" 4 3 SIM IA■ NORTIH moromommmmummosummusimmummimorommionsaromremummummomarammanimmormormminumusimmommommormarommummormommilim ittiii -�----�--i- t1-+++ I normilmilmoineloismilmamoomi I ..IIB I .. I I N I I I. 1 1 1 1 I I 11 M1 1 ®1 1 1 — 1 1 IMMII 1 r. 1 1 n 1 1 w 1 1 r. 1 1r• I Ir. 21111 11 EXISTING EXPOSED STRUCTURE I I i 11..11 e 11 ..I Ir. 1..11..11..1 NMI SCHEMATIC LIGHTING CONTROLS REQLIRED PER SECTION 1513 OF THE NREC. DAYLIGHT ZONES 1 AND 2 TO BE SWITCHED SEPARATELY FROM GENERAL LIGHTING. OCCUPANCY SENSORS REQUIRED IN ALL OF=ICES, CLASSROOMS, CONFERENCE ROOMS, WAREHOUSES AND STORAGE ROOMS. AUTOMATIC SHUT --OFF CONTROLS ARE REQUIRED =01R ALL LIGHTING INCLUDING TASK LIGHTING ON DEMOUNTABLE PARTITIONS.. EITHER OCCUPANCY SENSORS OR TIME SWITCHES ARE REQUIRED. EXISTING LIGHTING, RELOCATED LIGHTS SCHEMATIC PLAN' SEE BID DESIGN ELECTRICAL ELECTRICAL BID DESIGN WITH SEPARATE PERMIT. * OC = OCCUPANCY SENSORS AT NEW OFFICE AND CONFERENCE E EXISTING R RELOCATED N NEW %1 NORTH - ---I_ (E) STAIR SEE -- DETAIL 8/T-3 EXIST NG WAREHOUSE ETD (0) (0)— (0) =======47Z LINE OF -----•-I MEZZANINE AE3OVE FULL - HT. WALL ---- ALIGN WITH ��� MEZZANINE AE3OVE MEN, 1�C�2 \ SV (1.-477 RS -7 b • ALIGN tarrusurommorrailittioJ -ADD 5/8" GWB & INSULATION--' UP TO UNDERSIDE OF JOISTS --EXISTING SHEAR j WALL EXISTING COLUMN LOBBY/ SHOWROOM [10() SEALED CONCRETE FLOORING COLUMN! 91 3" TYP. INSULATED 6" WALLS -----� WITH GWB TO UNDERSIDE CF JOISTS, EVEN TOP EDGE •— 10' HIGH WALL ALIGN -`� FULL HT. WALL -- ALIGN Wf-H MEZZANINE ABOVE STAIR SEE DETAIL---• 8/T--3 SIM � 17 T>5 cJ <A 16 WOMEN EZ / SVjC2)L --RS DRINKING FOUNTAINS, >®�ti SEE DETAIL 11/T--1 (7---70 uS STAIRpT 4 k2 FINISHE COLORS SEE CORPORATE REAL ESTATE DESCRIPTION MEZZANINE CEILING PLAN (83' 5 MEZZANINE FLOOR PLAN 1/8• 4 CB)I • FOJR-PLEX OUTLET TOP © 18" AFF ;INTERIOR NORTH SIDE OF COLUMNS FOJR-PLEX OUTLET TOP © 18" AFF C� N 1 414 4N E. 7, 1 1.1 1 1 CC) 1 1 i i r \I 4411 PERM ETER NORTH SIDE OF PILASTERS 192' - STORAGE 22,500 S.F. 1/500 = 45 OCC. N1 Nj N ** N#1/ N N E 4 N • L) N ► NI N 311 Cd) PARTIAL 1ST FLOOR CEILING PLAN 1/8• 3 r"./5) impeammioroamasesinoramaTjariorneLlampLiec— N41 N N1� 147' N* N 3011 N i11 DISPLV - 31,967 S.F. 1/60 •- 532 OCC. EAT mi EXIT .R :I.P'_f•FE — - - - RiVET N-44 114--- Z 7 $ EXI ......L'IL.•.....-----=- .rrgh..........LL.,...........nso............m....mu.•LL.....................roh.........n.m........ aseummonommaninamarnalllimmionsimm REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232013 City of Tukwila BUILDING DIVISION EXIT PATHWAY N esc aniana myna. Now at LO N 211W N 3#11 L E 6' SHOWROOM 1/60 49 OCC. Erft E.A.T.D.: S.D.: 4 'LV SIM EXISTING WAREHOUSE [105 PARTIAL 1ST FLOOR PLANJ1 MINI MN -r 11111111::10=11111111 11...c111 rillIll_:1171MiseT_:l1_17mTIIII7mIIIIII71111f OFFICE 2,909 S.F. 1/100 = 29 OCC. Qvicv -7,71 EXIT ACCESS TRAVEL DISTANCE -- COMMON PATH EGRESS TRAVEL DIAGONAL , D [STANCE SEPARATION DISTANCE 635 OCCUPANTS - EX IT REQUIRED 5 PROVIDED L. no Imo RECEIVED CITY OF TUKWILA PERMIT CENTER MAXIMUM 250FT SPRINKLERED - M PG (3 Oto EXISTING PATHWAY EMERGENCY LIGHTING, MODFICATIONS PER SIEPARATE BID DESIGN ELECTRICAL SUBMITTAL NORTH OVERALL PLAN & EXITING (-1/12) ;:k :31., LLD ra (595) cc top co x: 2 44;: cm It: CD n ROYCE A. BERG, PRECIPAL 301 11 30TH AVE SOU1HEAST MERCER MOND, WA, 93040 (2)6)2M-6643 FAX 23046647 prommummormossommomosonimmormisto NO DESCRIPTION DATE PERMIT SUBMITTAL 4-22-5 on= smommommomommosioustammirmo *DATA CONTAINED ON THESE PLANS OR ILI.ECTRONIC FIU3 ARE PART OF THE CONSULTANTS INSTRUMBITS OF SERVICE: AND SHALL MANN THE PROFERTY OF THE CONSULTANT. SUCH DATA SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSTRUCTION OF THE REFERENCED PROJECT. ANY OTHER USE. REUSE: OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT." OVERALL PLAN & EXITING, FLOOR PLANS & CEILING PLANS File: 13009/T-2.dwg JOB NO.: 13009 DATE: SAM CHECK: RAB MI SHEET NO: _ ACT .L I-= -- -IFI•—.Fi 1.-1111M-1-1-1•11. 1 = -=- 24__ •B11 II II 1 I MI I I MI I I r. 1 Ws i. 11111111 SCHEMATIC LIGHTING CONTROLS REQUIRED PER SECTION 1513 OF THE NREC., DAYLIGHT ZONES 1 AND 2 TO BE SWITCHED SEPARATELY FROM GENERAL LIGHTING. OCCUPANCY SENSORS REQUIRED IN ALL OFFICES, CLASSROOMS, CONFERENCE ROOMS, WAREHOUSES AND STORAGE RC OMS. AUTOMATIC SHUT-OFF -CONTROLS ARE REQUIRED FOR ALL LIGHTING INCLUDING TASK LIGHTING ON DEMOUNTABLE PARTITIONS. EITHER OCCUPANCY SENSORS OR TIME SWITCHES ARE REQUIRED. EXISTING LIGHTING, RELOCATED LIGHTS SCHEMATIC PLAN, SEE: BID DESIGN ELECTRICAL ELECTRICAL BID DESIGN WITH SEPARATE PERMIT. * OC = OCCUPANCY SENSORS AT NEW OFFICE AND CONFERENCE E EXIST NG R RELOCATED N NEW NORTH FIELD VERIFY DIMENSIONS WITH SPRINKLER RISER LOCATION—r- 5'-2" FULL HIGH WALL STAIR SEE----' DETAIL. 8/T-3 /_� 4 pe —r, oF 7 Q— 11i II II II �J -12!_11 4� >-ALIGN 11111 il■i II II MI • -10' HIGH WALLS -1 .fi WALL ±42" r.m] LI) 3'x4" WINDOW © 36" AFF — CENTERED IN WALL In •li■II II III i OPEN OFFICE ±2,9C)9 S.F.. NET AREA SEALED PLYWOOD FLOORING IRE —FLUSH MOUNT 4-P LEX TYP. (4 LOCATIONS) 1 4'-6" 7.= GFlC G , BREAKROOM C20] VCT RS 0.5)— --- JL.417.= -1L-i 1c HIGH WALL RS -- 10' HIGH WALLS 6� T- jsity ALIGN FULL HIGH WALLS ----- STAIR SEE DETAIL 8/T--3 SIM DN UP 12 T-3 T13� SIM [�I ALIGN--7 OPEN OFFICE E?oz VCT FULL HIGH WALL--\ 12'-8" 4 3 SIM IA■ NORTIH moromommmmummosummusimmummimorommionsaromremummummomarammanimmormormminumusimmommommormarommummormommilim ittiii -�----�--i- t1-+++ I normilmilmoineloismilmamoomi I ..IIB I .. I I N I I I. 1 1 1 1 I I 11 M1 1 ®1 1 1 — 1 1 IMMII 1 r. 1 1 n 1 1 w 1 1 r. 1 1r• I Ir. 21111 11 EXISTING EXPOSED STRUCTURE I I i 11..11 e 11 ..I Ir. 1..11..11..1 NMI SCHEMATIC LIGHTING CONTROLS REQLIRED PER SECTION 1513 OF THE NREC. DAYLIGHT ZONES 1 AND 2 TO BE SWITCHED SEPARATELY FROM GENERAL LIGHTING. OCCUPANCY SENSORS REQUIRED IN ALL OF=ICES, CLASSROOMS, CONFERENCE ROOMS, WAREHOUSES AND STORAGE ROOMS. AUTOMATIC SHUT --OFF CONTROLS ARE REQUIRED =01R ALL LIGHTING INCLUDING TASK LIGHTING ON DEMOUNTABLE PARTITIONS.. EITHER OCCUPANCY SENSORS OR TIME SWITCHES ARE REQUIRED. EXISTING LIGHTING, RELOCATED LIGHTS SCHEMATIC PLAN' SEE BID DESIGN ELECTRICAL ELECTRICAL BID DESIGN WITH SEPARATE PERMIT. * OC = OCCUPANCY SENSORS AT NEW OFFICE AND CONFERENCE E EXISTING R RELOCATED N NEW %1 NORTH - ---I_ (E) STAIR SEE -- DETAIL 8/T-3 EXIST NG WAREHOUSE ETD (0) (0)— (0) =======47Z LINE OF -----•-I MEZZANINE AE3OVE FULL - HT. WALL ---- ALIGN WITH ��� MEZZANINE AE3OVE MEN, 1�C�2 \ SV (1.-477 RS -7 b • ALIGN tarrusurommorrailittioJ -ADD 5/8" GWB & INSULATION--' UP TO UNDERSIDE OF JOISTS --EXISTING SHEAR j WALL EXISTING COLUMN LOBBY/ SHOWROOM [10() SEALED CONCRETE FLOORING COLUMN! 91 3" TYP. INSULATED 6" WALLS -----� WITH GWB TO UNDERSIDE CF JOISTS, EVEN TOP EDGE •— 10' HIGH WALL ALIGN -`� FULL HT. WALL -- ALIGN Wf-H MEZZANINE ABOVE STAIR SEE DETAIL---• 8/T--3 SIM � 17 T>5 cJ <A 16 WOMEN EZ / SVjC2)L --RS DRINKING FOUNTAINS, >®�ti SEE DETAIL 11/T--1 (7---70 uS STAIRpT 4 k2 FINISHE COLORS SEE CORPORATE REAL ESTATE DESCRIPTION MEZZANINE CEILING PLAN (83' 5 MEZZANINE FLOOR PLAN 1/8• 4 CB)I • FOJR-PLEX OUTLET TOP © 18" AFF ;INTERIOR NORTH SIDE OF COLUMNS FOJR-PLEX OUTLET TOP © 18" AFF C� N 1 414 4N E. 7, 1 1.1 1 1 CC) 1 1 i i r \I 4411 PERM ETER NORTH SIDE OF PILASTERS 192' - STORAGE 22,500 S.F. 1/500 = 45 OCC. N1 Nj N ** N#1/ N N E 4 N • L) N ► NI N 311 Cd) PARTIAL 1ST FLOOR CEILING PLAN 1/8• 3 r"./5) impeammioroamasesinoramaTjariorneLlampLiec— N41 N N1� 147' N* N 3011 N i11 DISPLV - 31,967 S.F. 1/60 •- 532 OCC. EAT mi EXIT .R :I.P'_f•FE — - - - RiVET N-44 114--- Z 7 $ EXI ......L'IL.•.....-----=- .rrgh..........LL.,...........nso............m....mu.•LL.....................roh.........n.m........ aseummonommaninamarnalllimmionsimm REVIEWED FOR CODE COMPLIANCE APPROVED MAY 232013 City of Tukwila BUILDING DIVISION EXIT PATHWAY N esc aniana myna. Now at LO N 211W N 3#11 L E 6' SHOWROOM 1/60 49 OCC. Erft E.A.T.D.: S.D.: 4 'LV SIM EXISTING WAREHOUSE [105 PARTIAL 1ST FLOOR PLANJ1 MINI MN -r 11111111::10=11111111 11...c111 rillIll_:1171MiseT_:l1_17mTIIII7mIIIIII71111f OFFICE 2,909 S.F. 1/100 = 29 OCC. Qvicv -7,71 EXIT ACCESS TRAVEL DISTANCE -- COMMON PATH EGRESS TRAVEL DIAGONAL , D [STANCE SEPARATION DISTANCE 635 OCCUPANTS - EX IT REQUIRED 5 PROVIDED L. no Imo RECEIVED CITY OF TUKWILA PERMIT CENTER MAXIMUM 250FT SPRINKLERED - M PG (3 Oto EXISTING PATHWAY EMERGENCY LIGHTING, MODFICATIONS PER SIEPARATE BID DESIGN ELECTRICAL SUBMITTAL NORTH OVERALL PLAN & EXITING (-1/12) ;:k :31., LLD ra (595) cc top co x: 2 44;: cm It: CD n ROYCE A. BERG, PRECIPAL 301 11 30TH AVE SOU1HEAST MERCER MOND, WA, 93040 (2)6)2M-6643 FAX 23046647 prommummormossommomosonimmormisto NO DESCRIPTION DATE PERMIT SUBMITTAL 4-22-5 on= smommommomommosioustammirmo *DATA CONTAINED ON THESE PLANS OR ILI.ECTRONIC FIU3 ARE PART OF THE CONSULTANTS INSTRUMBITS OF SERVICE: AND SHALL MANN THE PROFERTY OF THE CONSULTANT. SUCH DATA SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN FOR THE CONSTRUCTION OF THE REFERENCED PROJECT. ANY OTHER USE. REUSE: OR MODIFICATION OF THE FILES WITHOUT THE CONSULTANT'S PRIOR WRITTEN CONSENT, WILL BE AT THE RECIPIENT'S SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO THE CONSULTANT." OVERALL PLAN & EXITING, FLOOR PLANS & CEILING PLANS File: 13009/T-2.dwg JOB NO.: 13009 DATE: SAM CHECK: RAB MI SHEET NO: