Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG13-071 - SAHALE SNACKS - GAS PIPING
SAHALE SNACKS 3411 S 120 PL PG13-071 City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: htto://www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3411 S 120 PL TUKW Project Name: SAHALE SNACKS PLUMBING/GAS PIPING PERMIT Permit Number: PG13-071 Issue Date: 05/20/2013 Permit Expires On: 11/16/2013 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Contact Person: Name: BRYAN GALVIN Address: 4102 B PL NW , AUBURN WA 98001 Email: bryang@universalrefrig.com Contractor: Name: UNIVERSAL REFRIGERATION INC Address: PO BOX 614 , AUBURN WA 98071-0614 Contractor License No: UNIVERI159RF Phone: 253-939-5501 Phone: 253 939-5501 Expiration Date: 04/01/2014 DESCRIPTION OF WORK: INSTALL 45 ADDITIONAL FEET OF GAS PIPING ONTO EXISTING SYSTEM TO SUPPORT (2) OWNER SUPPLIED WATER HEATERS. Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: $1,400.00 $120.75 I hereby certify that I have read and e governing this work will be complied anu vith, Uniform Plumbing Code Edition: International Fuel Gas Code Edition: 2009 2009 Date: ped this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: J' 7 * f 3 AC 'IA ,1114 PERMIT CONDITIONS Permit No. PG 13-071 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. rine IPrA/1 n PG 13-071 Printed: 05-20-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. T`=' 1 x--0 71 Project No. Date Application Accepted: 7— ( 3 (For office use only) Date Application Expires: 6 PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: /0230 Y7GY Site Address: 176// a /Z071.4 Tenant Name: Jai kc I SA.n e...kS PROPERTY OWNER Ha'r'e' Bryan , Heath Shane Chuck Address: 4102 B P1 NW Name: 5--,4 cert. Phone: (253) 939-5501 Fax: (253) 735-3432 Address: / Z 2_611,‘( -u (c,,,/1. /474(//;(v-,7/. City:Seo State: `/� P: 98/6A? CONTACT PERSON — person receiving all project communication Ha'r'e' Bryan , Heath Shane Chuck Address: 4102 B P1 NW Address: 4102 B PIM,/ City: Auburn State: WA D Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: 461.y el @universalrefrg.com Suite Number: Floor: New Tenant: ❑ Yes Lo PLUMBING CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B P1 NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNNERI 159RF Exp Date: 04/01/2014 Tukwila Business License No.: BUS -0993124 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): (7 yS(aea (fe 1 d f c(5/7e— Building Use (per Int'I Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer H:\Apphcahons\Fomis-Applications On Line\2011 Applications\Plumbmg Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: AUTHO JL4' erry eschlimann Mailing Address: 4102 B P1 NW H: Applicanons\Forms-Apphcattons On Line N.2011 Applicatans\Plumbing Pertntt Application Revised 8-9-11.docx Revised: August 2011 bh Date: S/1�7Z01/ Day Telephone: (253) 9139-5501 Auburn WA 98001 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 1023049069 Address: 3411 S 120 PL TUKW Suite No: Applicant: SAKALE SNACKS RECEIPT Permit Number: PG13-071 Status: PENDING Applied Date: 05/07/2013 Issue Date: Receipt No.: R13-01543 Payment Amount: $120.75 Initials: WER Payment Date: 05/07/2013 03:13 PM User ID: 1655 Balance: $0.00 Payee: UNIVERSAL REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 46721 120.75 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES 000.322.103.00.00 96.60 000.345.830 24.15 Total: $120.75 Prinforl• (15_(17_9f113 INSPECTION RECORD Retain a copy with permit .,GI?, -071 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: HALE._ G W A KS, Type of Inspection: '- Address: LI 11 5 •IaoP1 Date Called: Special Instructions: Date Wanted:. (O ... -, -. � �j a.m. m. 1p. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval.. COMMENTS: r •, I 16A -DIF b /a /AJ Inspec r: Date: REINSPECTION FEE REQUIRED. F'rior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call toschedule reinspection., INSPECTION NO. INSPECTION RECORD Retain a copy with permit P613-D-7� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: S A NAL -.F StJACi`S Type of Inspection: IRau6t-I-.1 N GA Address:Date 3y11 S�- IaO?L Called: Special Instructions: Date Wanted:. 5- 2 1- 13 a.ml p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 EINSPECTION FEE REQ IRED. Prior to next inspection. fee must be aid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. Date:. S-zt— i Ye• PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-071 PROJECT NAME: SAHALE SNACKS SITE ADDRESS: 3411 S 120 PL X Original Plan Submittal Response to Correction Letter # , DATE: 05-07-13 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMEN TS: ti 171 � I1Tding Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator 1111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1741 Incomplete DUE DATE: 05-09-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW. 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06-06-13 Approved ❑ Approved with ConditionsNI' Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use; Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople P ter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with List to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company UNIVERSAL REFRIGERATION INC 2539395501 Po Box 614 Auburn WA 980710614 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600599723 Active UNIVERI159RF Construction Contractor 12/6/1985 4/1/2014 Commercial/Industrial/Refrig Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVERIOOOBO UNIVERSAL REFRIGERATION INC Electrical Contractor Hvac/Rfrg Ltd Energy Unused 1/20/2000 1/20/2014 Active Business Owner Information Name Role Effective Date Expiration Date GATES, CHRISTOPHER A President 03/29/2012 Amount GALVIN, BRYAN S Vice President 03/29/2012 01CG749762-9 RAEDER, STEVEN C President 01/01/1980 03/29/2012 VERNON, GUY E 03/18/2013 01/01/1980 01/01/1980 JACKSON, SHELDON G 04/01/2012 01/01/1980 01/01/1980 OSENBAUGH, CHARLES R $1,000,000.00 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 AMERICAN STATES INS CO EX903622 12/06/2001 Until Cancelled $6,000.00 03/18/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 27 American States Insurance Co 01CG749762-9 04/01/2013 04/01/2014 $1,000,000.00 03/18/2013 26 American States Insurance Co 01CG749762-8 04/01/2012 04/01/2013 $1,000,000.00 03/20/2012 25 American States Insurance Co 01CG7497627 04/01/2010 04/01/2012 $1,000,000.00 03/07/2011 24 AMERICAN STATES INS CO 01CG7497625 04/01/2009 04/01/2010 $1,000,000.00 03/09/2009 23 AMERICAN STATES INS CO 01CG7497624 04/01/2008 04/01/2009 $1,000,000.00 03/11/2008 22 FIRST NATL CO OF AMERICA 01CG7497623 04/01/2007 04/01/2008 $1,000,000.00 03/01/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period httns.//fnrtress_wa. rry/lni/bbin/Print.asnx 05/20/2013 1 409.4 MP REGULATOR VALVES VALVESHALL BEINSTALLED IMMEDIATELYAHEAD OF EACH MP REGULATOR A LISTED SHUTOFF 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1, 409.5.0, OR 409.5.3 3 VENT LIMITERS ARE DESIGNED FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUETTO DIAPHRAGM FAILURE IS CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13M 5 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REQUIRED. 4 411.1.6 UNIONS 0: A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) OF THE APPLIANCE. 5 410.1 PRESSUREREGULATORS GULATORS E. A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. IZ21.80.:ACCESS SHALL BE PROVIDED TO PR E PRESSURE REGULATORS.PRS RE WITH AN SSURSU LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING S B - APPROVED FOR E A RO INSTALLED ON THE EXTERIOR OF THE BUILDING SHALLPP REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS OUDOOR INSTALLATION. P 6 A TEE: FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE AS A SEDIMENT TRAP. A PRESSURE -MEASURING INSTRUMENT AND TO SERVE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF S , . ETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. TEE.FITTINGWITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10PIPEDIAM ' 7O A INSTRUMENT. SHALLBEPOSITIONED ALLOW THE_CONNECTION OF A PRESSURE -MEASURING SUCH TEE FITTING TO AFF ABOVE FINISHED FLOOR BDD BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE DB DECIBEL DEG DEGREE DH DUCT HEATER DN DOWN EA EXHAUST AIR EER ENERGY EFFICIENCY RATIO EG EXHAUST GRILLE ESP EXTERNAL STATIC PRESSURE EWT. ENTERING WATER TEMPERATURE EXH EXHAUST. FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FPM FEET PER MINUTE FSD FIRE ANDSMOKE DAMPER GA GAUGE GF GAS FURNACE GPM GALLONS PER MINUTE GRD GRILLE, REGISTER, DIFFUSER GWB ' .. GYPSUM WALLBOARD HP : HORSEPOWER, HEAT PUMP IDINSIDE DIMENSION `: IRH INFRARED HEATER KW KILOWATT MBH THOUSAND BTU PER HOUR MCD MOTORIZED CONTROL DAMPER NC . NOISE CRITERIA NIC : NOT IN CONTRACT NTS NOT TO SCALE OBD OPPOSED BLADE DAMPER OC : ON CENTER OD OUTSIDE DIMENSION OR DIAMETER T OSA OUTSIDE AIR P D ' ' . PRESSURE SUR E DRO S RPM REVOLUTIONS PER MINUTE. RA RETURN AIR RAG RETURN AIR GRILLE SA SUPPLY AIR SG SUPPLY GRILLE SP STATIC PRESSURE SSG SIDEWALL SUPPLY GRILLE TBD TO BE DETERMINED INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN GAS METER HARDLID SUPPLY DIFFUSER HARDLID RETURN GRILLE. FIRE DAMPER TRANSFER GRILLE TYPICAL VARIABLE AIR VOLUME VARIABLE FREQUENCY DRIVE VENT TO ROOF VARIABLE VOLUME AND TEMPERATURE ROUND DUCT UP DUCT INSULATION SHALL MEET REQUIREMENTS OF SECTION 1414.2 OF THE 2009 WSEC AND TABLE 14-5. 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2009 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUTDOWN POWER TO THE UNIT UPON ACTIVATION AND A "SUPERVISORY" ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 606.2.1. 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. 4 ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2009, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2009, SECTION 1413. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE FOR INSPECTIONS. 6. ; ALL HVAC EQPM. TO BE LABELED TO THE SPACE SERVED. TO TDUCTS SUPPORTED AT EACH DIRECTION CHANGE . ; BE S VERTICAL' AT 12 -0 MAX. HORIZONTAL A T 10-0 MAX. A ` WITH STRAP, OR 81-0" MAX. TRAPEZE SUPPORT. 8THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT .:: SETBACK WITH 5 DEGREE DEADBAND. 9THE HVAC INSTALLATION TION SHALL BE COMPLETE WHEN ALL . E BEEN SATISFIED. THIS SECTIONS OF 1416 WS C HAVE... SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0&M AND A COMM - MANUALS, SYSTEM BALANCEREPORT, COMM- ISSIONING ING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2H WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: UNIVERSAL REFRIGERATION AIR CONDITIONING - HEAT PUMPS REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: ' UNIVERI 159RF AUBURN: (253) 939-5501.. TACOMA: (253) 922-3141 SEATTLE:: (253) 839-2126 FAX: (253) 735-3432 .0 OX 614 - AUBURN WASHINGTON 98071 ()UNIVERSAL REFRIGERATION DRAWING -2001 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. ROUND AND FLATDUCT SPIRAL LOCK OVAL SP SEAMS IN WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. NREC FORMS, DUCTING PLANS (BALANCING FEATURES), AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG WITH A MECH. PERMIT AT THE TIME OF THE TENANT IMPROVEMENT PERMIT. 12. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF 1415 OF THE WSEC: PERMIT ISSUE CO u7 T 1 ROUND DUCT DOWN REVIEVVEDFOR CODE COMPLIANCE APPROVED MAY 132013 tLJ City of Tu iIa BUILDING ISION DIFFUSER TAG REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a newplan submittal and may include additional plan review fess. 1. INSTALL (3) REFRIGERATION SYSTEMS. 2. INSTALL (2) DEHUMIDIFICATION SYSTEMS. 3. INSTALL (2) NEW EHXAUST FANS. 4. REVISE (2) EXISTING MAKE UP AIR SYSTEMS. 5. REVISE (1) EXISTING EXHAUST SYSTEM. 6. INSTALL GAS PIPING FOR (2) WATER HEATERS. MODEL NUMBER AREA OF SERVICE VOLTAGE/PHASE KMP368MA-S4A SEPARATE TE. PERMIT f QRED FC MeUIchanical Electncai Plumbing 0 Gas Piping :Y of Tukwila lla DIVISION. FILE COY No. .11 n review approval _ s subject to errors and omissions.: of construction documents does not authorize tl; .. ict on of any adopted code or ordinance. Recei {prof . FieRi Copy and . " 1 I I> le ,411i :d; . ;. RV: 1"r;°' REFRIGERANT KESB120H8-HT4B REVISIONS No changes shall bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new :plan submittal and may inc ude additional' plan revieV,I fees RECEIVED CITY OF TUKWILA MAY 072013 PERMIT CENTER. BRAND NAME LOCATION CENTRAL BLOWER MECHANICAL MEZZANINE NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. - AIR CONDITIONING - HEAT PUMPS - REFRIGERATION CONTRACTOR'S LICENSE NUMBER:', AUBURN: ` (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 Qc UNIVERSAL REFRIGERATION DRAWING -2001 1-5/8"0 SUCTION HEADER 1-5/8"0 x 7 8"0 REFRIGERANT PIPING REVIEWED FOR CODE COMPLIANCE APPROVED MAY 132013 NOTE: " COORDINATE SONDE I''i LOCATIONS I ITH PLU GING-CONTRACTOR- /8"0 x /8"0 REFRIGERAN PIPING RECEIVED CITY OF TU C'A'ILA AREA OF WORK MAY 072013 SCALE: NTS NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. 1 4 USE EXISTING 1,90 HAUST FAN ON EQ' EFItI - AIR CONDITIONING- HEAT PUMPS -REFRIGERATION - CONTRACTORS LICENSE NUMBER: AUBURN: (253) 939-5501 TACOMA: (253) 922-3141 SEATTLE: (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 °UNIVERSAL REFRIGERATION DRAWING -2001 UNIVERI 159RF 18x18 CD 600 CFM 24x24 EG PERMIT ISSUE W 0 1 /18x18 CDD `1;500 CFM -16"0 118x18 CD T 24x24 Ee 18x18 CD 1500-C1�6" 18x18 CD +2o'—o1 600 CFM 250,000 TU WATER HEATERS UMBING RETIE:®IVID FOR I�L A� CODE C E APPROVED MAY 13 2013 S (5 PSI City of Tukwila BUILDING DIVISION REUSE EXISTING 1,200 CF EXHAUST FAN ON EQPM. I1 Z (STING 5,000 AIR UNIT ONE EXISTING 12,000 CFM M\KE UP AIR UNIT ON EQPM. EZZ. PROJECT START DATE: 4/23/13 NSTALLWNEW"WALL t OUV E EXISTING PENETRATIO VENTILATION/GAS PIPING PLAN SCALE: 1/8" 1'-0 RECEIVED CITY OF TUKWILA LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. NOTE: These plans are diagrammatical only. Please verify all dimensions at job site. 4x30 PR. OUTSIDE AIR H;iT1 4x24 RAG 20x20 SAG Ox20 SAG 4x30.PRO.GES OUTSIDE AIR HOO 20110 DN THROUG ' s PRO ESS REVIEWED FOR CODE COMPLIAi CE; APPROVED MAY 1 3 2013 RECEIVED. CITY OF TUKWILA 0 - AIR CONDITIONING HEAT PUMPS - REFRIGERATION - CONTRACTORS LICENSE NUMBS AUBURN: (253) 939-5501 SEATTLE: (253) 839-2126 R: UNIVERI 159RF TACOMA: (253)922-3141 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 0 cC 0 w 0 Z 0 (i) w PERMIT ISSUE r PRINT/PLOT DATE: 4/24/13 PROJECT START DATE: 4/23/13,