HomeMy WebLinkAboutPermit PG13-087 - BOEING #2-80 - GAS PIPINGBOEING #2-80
8123 EAST MARGINAL
wys
PG1 3-087
City oil/Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No.: 0001600020
Address: 8123 EAST MARGINAL WY S TIIKW
Project Name: BOEING #2-80
Permit Number: PG13-087
Issue Date: 06/21/2013
Permit Expires On: 12/18/2013
Owner:
Name: BOEING COMPANY THE
Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124
Contact Person:
Name: KEN PHILLIPS
Address: 8657 S 190 ST , KENT WA 98031
Email: K.PHILLIPS@DESIGN-AIR.COM
Contractor:
Name: DESIGN AIR, LTD.
Address: 8657 SOUTH 190TH ST , KENT, WA 98031
Contractor License No: DESIGL*212DG
Phone: 253 854-2770
Phone: (253) 854-2770
Expiration Date: 03/07/2014
DESCRIPTION OF WORK:
INSTALL GAS PIPING FROM POINT OF CONNECTION TO NEW OWNER SUPPLIED HEATER
Value of Plumbing/Gas Piping:
Fees Collected:
Electrical Service Provided by:
$14,720.00
$120.75
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
amin
th,
Uniform Plumbing Code Edition:
International Fuel Gas Code Edition: 2009
2009
Date:
this permit and know the same to be true and correct. All provisions of law and ordinances
ether specified herein or not.
The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions
on the back of this permit.
Signature:
i%
Date:
Print Name: 0F_
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
.1....• limn A/A!1
on AQ7 Drin}ud• na291_)A1
PERMIT CONDITIONS
Permit No. PG 13-087
1: ***PLUMBING AND GAS PIPING***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
doc: UPC -4/10
PG13-087 Printed: 06-21-2013
CITY OF TUKA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, IVA 98/88
http://www.TukwilaWA.gov
•
Plumbing/Gas Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(2, [ID -DM
040) ttl
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
Mato --oow
Site Address: Bldg 2-127 Yard 1823 E Marginal Way South — Seattle, WA Suite Number: Floor:
New Tenant: ❑ Yes X.No
Tenant Name: The Boeing Co.
PROPERTY OWNER
Name: Ken Phillips
Name: The Boeing Co.
Address: 8657 S 190th Street
Address: PO Box 3707 M/C 20-00
City: Kent State: WA
City: Seattle State: WA
Zip: 98124
CONTACT PERSON — person receiving all project
communication
Name: Ken Phillips
Address: 8657 S 190th Street
Address: 8657 S 190th Street
Phone: 253.854.2770 Fax: 253.854.6131
City: Kent State: WA
Zip: 98031
Phone:253.854.2770 Fax:253.854.6131
Email: k.phillips@design-air.com
PLUMBING CONTRACTOR INFORMATION
Company Name: Design Air, Ltd.
Address: 8657 S 190th Street
City: Kent State: WA Zip: 98031
Phone: 253.854.2770 Fax: 253.854.6131
Contr Reg No.: DESIGL*212DG Exp Date: 03/07/2014
Tukwila Business License No.: BUS -0101108
Valuation of Project (contractor's bid price): $ 12,533
Scope of Work (please provide detailed information):
Install Gas Piping to new PSE Meter
Building Use (per Int'I Building Code):
Occupancy (per lnt'l Building Code):
Utility Purveyor: Water:
H:\Applications\Forms-Applications On Line\201 I Applications \Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Sewer:
Page 1 of2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity oelow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping system
serving 1-5 inlets/outlets
for a specific gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
40,411
Print Name: Mike Deniger
j�
Mailing Address: 8657 S 190th Street
1r.\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docz
Revised. August 2011
bh
Date:6//.2
Day Telephone: 253.854.2770
Kent
City
WA
State
98031
Zip
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
Parcel No.: 0001600020 Permit Number: PG13-088
Address: 8123 EAST MARGINAL WY S TUKW Status: PENDING
Suite No: Applied Date: 06/18/2013
Applicant: BOEING #2-127 Issue Date:
Receipt No.: R13-01909
Payment Amount: $120.75
Initials: JEM Payment Date: 06/18/2013 01:49 PM
User ID: 1165 Balance: $0.00
Payee: DESIGN AIR
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 97596 120.75
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
GAS - NONRES
PLAN CHECK - NONRES
000.322.103.00.00 96.60
000.345.830 24.15
Total: $120.75
Drinlurl• (IAA A27111'i
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
t3 -���
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 e , (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Projec
Type !<InspAec(tion
Address:
c 23
_ Ant�'NA-L
Date Iled:
(cou6
__ ,
Special Instructions:
Date Wante r+//�
t�
''� a �.
p.m.
Requester:
Phone No: —
34
/--2
3,3
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
I I REINSPECTION FEE R QUIRED. Prior to next inspection, fee must be ,
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Pe
Plan revie
Approval
thc: v dation of any ado
of approved Feld Copy
STEAM HEATED
PROPANE
VAPORIZER
SOUTH WALL
OF LASF
8"-A300
1 �
M621
COPY
V' (-71
0
C 12"-A300 EL 3'-6 3L4"
ABOVE GRADE
nE PSV V-27
PROPANE
s subject tot&rors
d nmi, Binns_
cons ru ►documents does nct 4.
€a
ABOVE \
code or ordinance;. Rec pt
acknowledged:
BY
Date: 4/z/13
PIPE
SUPPORT
City Of Tbkwila
BUILDING DIPN- NO
9"
SCALE: 1 /4"=1'-0"
13
HEATER (Th
1M212,1M62,RFM62 44621
6001
FLANGE
O
6"-A1000 (U/G)—
TO NBF — C 12"-A300 (U/G) TO
NEW, BTWT, AND 2-85
M621
M62121
20'-0"
REVISIONS
a3'!s3/a'
No changes shall be made to the scopervE C71^DE
of work without prior approval of
Tukwila Building Division. /�
NOTE: Revisions will require a new plan submittzl
and may ins udet 1ddtionai plan review fee 3.
I
USF ROOF
20'-0"
SOUTH WALL
OF LASF
13"
l-
jj P. P.O.C.
} s ''�. •LVE IN RISER
'�' EE 2.YD
�. 2 ' X4"
� - PSV V-2 • CONT.
SEISMIC/
olsc RI VALVE
S 621
N_ 4" M�
8"-A1r.. (U/0) Ne '�
TONG
2 .A3oo (u/c) TD
,r4.11.=.11'.::4:11.=.41NBjBIWf, AND 2 -BS II
V101 PRV102 V44
1000 (U/0)
4" 4"
-DJ
V144 V143
Addendum 2 Feb 26 2013
1) Cold air inlet pipe will be installed by Boeing to align with Stahl
flange without a horizontal bend. Boeing will furnish the air pipe
between the Stahl flange and the supply pipe, for installation by
contractor. See drawing 750X1001
2) Contractor shall cut off and reweld flange on hot air pipe at the
location shown on 750x1001. Boeing will fumish the pipe between
that flange and the Stahl flange, for installation by contractor.
3) Contractor is to fumish and install the gas piping. Connect to
Stahl heater at location shown on Dwg 34141
1
134 FOR
M621
-12"x8"
�8" RUPTURE
DISC
PSV 0-27
V101
PRV102
V44
SAFETY VALVE RELIEF PIPINQ
(RUPTURE DISC PIPING SIMILAR)
VENT TO ATMOS
VENT PIPE
C VALVE
OUTLET
12"x8"
RED TEE
CAP
DETAIL
SCALE: N
12-A3
1C-0"
GRADE
�tl
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
EL City of
BUILDING
V143
V144
EL 2'-11"
ABOVE GRADE
\I�
1-01 a a I
SECTION
SCALE 1/4"=1'-0"
M62.±4621
BG)Q # TO )==')
S
7* 4-0 PPPE-
ITEMS SHOWN ARE
PART OF VALVE
ASSEMBLY
t✓
la
ISION
CL 12-A300 (u/G) TO
NBF, BTWT, AND 2-85
GENERAL NOTES
1. FOR MECHANICAL PIPING GENERAL NOTES, SEE
DRAWINGS 2-YD-M2D AND 2-YD-M2b.
2. FOR MECHANICAL PIPING LEGEND AND SYMBOLS, SEE
DRAWING 2 -YD -MO.
REFERENCE DRAWINGS
2-83-OM110
2 -YD -M3
2-YD-M3b
2 -YD -M134
2 -YD -M325
1 > 2-83-E533
2 -YD -E84
2-83-E535
2-83-E536
13>
PLUMBING PLAN
COMPRESSED AIR BLOCK DIAGRAM
HIGH PRESSURE AIR DIAGRAM
PLUMBING PIPING
HP AIR SYSTEM PRV INSTR. LOCATION PLAN
PLC -117 I/O SCHEMATICS SHT. 1
120/208V & GROUND
PLC -117 I/O SCHEMATICS SHT. 3
PLC- 0 SCHEMATICS S 1 4
CONSTRUCTION NOTES
ISOLATE AND PURGE GAS LINE. REMOVE 6" CAP
AND SMALLER VALVE ON TOP. REPLACE WITH
6" RATED SHUT OFF VALVE IN RISER. RUN PIPE FROM
NEW VALVE TO STAHL HEATER. PIPE AND FITTINGS
TO MATCH EXIST. ADD SEISMIC VALVE PAINT PIPE BLACK
TO WEATHER PROOF. LABEL NEW PIPE NATURAL GAS.
RUN NEW PIPE. SUPPORT PIPE AT THE APPROX
INTERVALS SHOWN. PIPE TO BE 2'-0" ABOVE
GRADE(APPROX.) TO MATCH TIE-IN POINT.
SEEM 22 FOR PIPE SUPPORT DETAIL
TIE INTO DEVICE GAS CONNECTION AT THIS POINT.
® MODIFY SUPPLY AND RETURN AIR TO TIE INTO
STAHL HEATER. FIELD VERIFY REOUIRED MODIFICATIONS.
AIR PIPE MATERIAL,INSULATION AND FITTINGS TO MATCH EXIS
INSULATE HOT AIR PIPE ONLY. SEE ATTACHED CUSTOMER
GENERATED DRAWINGS FOR AIR PIPING DETAILS.
FIELD VERIFY PIPE ROUTE THIS AREA. PIPE MAY
NEED TO RISE TO PROVIDE MAINTENANCE ACCESS.
CONTRACTOR TO DETERMINE BEST ROUTE IN FIELD.
IImII
044
DOMING PIPING
2111
•
► 4111.11l► "�►SLI■0.111r
PRV102 V101 '�
111'
SECTION
SCALE: 1/4"=1'-0"
E>0
62112 -YD -
91
AUXILIARY
REGULATOR
FOR TESTING
(NOT USED)
p
PI HIGH
I PRESSURE
REGULATOR
PARATE PERMIT
EQUIRED FO
Mitheeicel
l.s
Electrical
Iumbing
❑ Gas Piping
DETAIL PLAN -WITH HEATER n
SCALE: 1/4"=1'-0"
1M112,1M212 44621
SYM
BY
041E
5044
DA
RECORD DRAWING
4982179
HGI/HEW
1.15.99
A
ADD PIPE 4100673098
BOWL
4/7/03
CHANGE DWG FROM YD TO 02-080
WDB
04.07.10
INSTALL STAHL HEATER
ID#19719
WD8
2.8.13
VOLUME
BOOSTER
FILTER
POSITIONER
City of Tukwila
Bl�ILQIN[, DfV
--me+31Lm
;V44
M6211.1+...4621
985 PSIG
TO NBF
ISI
A1000
A300
EL 2'-11"
ABOVE GRADE
RECEIVED
V-14LITY OF TUKWILA
V-144 JUN 1 8 2013 E
L_5 PSIG
9 TO LASF
CONTROL VALVE DIAGRAMP&tS 0'61
1985 PSIG
FROM
2 -PERMIT CENTER
SCALE: N.T.S. M�21
/ 195 DESIGN AND/OR
SPECIFICATION IS APPROVED
glAramezArce
0
H. WARDELL
LHLCKtu
S. SHRIVER
APPROVED B0
DEPT.
DATE
S. 0041056
CHECKED
R. BERRY
APPROVED
R. BERRY
APPROVED
L. COSTELLO
12.22.98
2.08.99
12.12.98
2.08.99
2.08.99
2.08.99
5 s COMPRESSED AIR REDUCING STATION
SECTION AND DETAILS
CURRENT REVISION
1419719
SYMBOL
DA
2.8.13
TITLE
MECHANICAL MASTER
02-080
PLANT 2
SHEET
M621
MEIN
1000673098
COMP
2-080-M621
6
5
4
3 b 2
1
PONE
X
REV DESCRIPTIONIONs
X X
o TE
APPROVED
D
—
D
261.00 Existing Pae
I
60.00
Pad Extension
1 \
I /Man Hole Cover
AY--{
REVIEWED FOR
1
---____L..---
CODE COMPLIANCE
APPROVED
JUN 21 2013
C
�;
_
1
)
•
City of Tukwila
BUILDING DIVISION
c
- 54.00
1
�I�
Stahl Heater
/
i
6', 60010 Flanges /
Neater Outlet
\ 6',
Heater
3001b Flanges
Inlet
Noise
SSGn�5s.
,�v/J���
Es),
(/
Lab \
>
S SG E n
n
II
...
_ _EL___
_L'—
Line
of Responsibility
h' ��
Esistinp Structure
1111/
D
i
I
i /
B
.•
Noise ois-
_
Noise
�.� -- Lab
t
t H
A.t—_i
B
k.W �°
RECEIVED
,�
:
--��
�~�..III
CITY OF TUKWILA
c
L
Plan view
Scale: ,:,D
------.
� ,
�
JUN 1 8 2013
,
PERMIT
A
NOTES:
1O AIR CD/EIRE/AMINO
PLUMBINO COMPONENTS SHOWN ON THI5
i
CENTER
Section view A -A
MUSING Dal BE FURNISHED BV NOISE LAB Scale: 1 10
CATIA DATASET NAME: 7500100 S0/ R --
CATIA DATABASE NAME: \\fi1 blv-15\enpdes ign\Archives\Catia_V5_Archives\Modelo\75XX
__
X
p
n
r-
Noise - LSAT\
.
7:?er" .a
.:�," .,"
..
-1
GRA..
0/0/10
BOEZING
g
PART 110.
NEXT MCA%1ECx6G
1"OGR.N
LSAFxxxx
CORPORATE OFFICES29124
1
Gs
STRESSIST
-
- -
-
-
- -
E< 1
EVA/SR No
1
UNLESSAPPLOTHERWISE IED
1sloN ARE
-
.12 n.
ErA
2
Inst' 1, GE -UPS Plumbing
- 1 -
- 1
-01
Inst•1 { - _ _
-
-
- 1 -
Iv INCHES
eaaruuwE No
1
BOEING PROPRIETARY
_
- -
-1 r
6E00
F.nT an
NwE
ANGLES
v6
7
P...,n.
.n112
sizE
CAGE aME
MAG.
1, ..,,..ax, 0000..: -
y5F0 ON
I06211FVINS MAID
CA 9120021 1P 05' 100' I SPECIFICATION
MCP s:II
Ns -1R
11216R
P1 -1R: I REV
MOLD
J1
e(1
750X1001
g
_ j .05 �,N
..T ................1,.....,,... 750x1001 1110.1
PARTS LIST
x....026
B-XT64
000 28 191 1 of a
a
6
5
4
3 4 2
1
SOUTH WALL
OF LASE
STEW HEATED
PROPANE
VAPORIZER
8"-A300
1-1/2' STM
3/4" C
1
PROPANE PUMP
PROPANE TANK NOT SHOWN TO -
PROVIDE ALTERNATE LOCATION
FOR HEAT EXCHANGER SEE
M621 FOR PROPANE TANK.
PROPANE HEAT EXCHANGER
fi��
PIPE
SUPPORT
8"-A300
300/ 1-1/2" STM
FLANGE
PC
61
'
6
M62,4!..940
CONDENSATE
PUMP DETAIL
(( )1
8"M6'
— V101
I CP
8"K6"
(WP 2)
Tritx6
600/ -
FLANGE
DETAIL PLAN- STEAM
SCALE: 1/4"=1'-0" 1M62,1M212 M621
3/4" SOLENOID VALVE
ASCO{j822A50, N.C.
SARCO P/T REGULATOR
3-30 PSI
BYPASS
1-1/2" STM
03
PRV102 V44
4' 4"
IY-`D
V144 V143.
(u
VERTICAL
3/4" C
2 V
1
PSV V-27
£8'R RE
DISC
2"-A300 € EL
10'-0" ABOVE
GRADE
EL 2'- 1'
ABOVE GIDE
q ABOVE GRADE
-�8'-A1000 (U/G)
TO NBF
� \ 1
8 CL NBF12"-A300 (U/AND G) 2T0
, 8TWT, -85
1-1/2" STM
TYP. TRAP ASSEMBLY
STEAM SCHEMATIC
SCALE: NONE
M622
VACUUM BREAKER
AR 11-1(1000)
8"
U -BOLT
r1/2"
TOS
co
9"
—C6x8.2
2" SCH.80
z
CC
CC
11-1
t,4
DETAIL PIPE SUPPORT
M621 M622
SCALE: NONE
RELOCATED HEAT EXCHANGER(NOW REMOVED)
AIR PIPING BY OTHERS.
EL
GENERAL NOTES
REFERENCE DRAWINGS
CONSTRUCTION
NOTES
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
JUN 1 8 2013
PERMIT CENTER
REVISION
RECORD DRAWING
J/982179
80
HCI/HEW
APPROVED
DATE
SYM
80
AP RCAED
DATE
1.15.99
CREATE DWG FROM 621
WDB
04.19.10
A STEAM & CONDENSATE
10/7535 WDB
05.13.10
B INSTALL STAHL HEATER ID/19719 WDB
2.8.13
?1,1__AerArzArc.
ACCEPTABIUTY
11110 DESIGN AND/OR
SPECIDCARON IS APPROVED
APPROVED BY
DEPT.
DATE
01AwN
H. WARDELL
O
S. SHR
S. SHINER
THDWEID -
S. SHRNER
CHECKED
R. BERRY
APPROVWD
R. BERRY
301E
12.22.98
2.08.99
12.12.98
2.08.99
2.08.99
COMPRESSED AIR DETAILS
SECTION AND DETAILS
CURRENT REVISION
10119719
SYMBOL
DATE
2.8.13
APPROVED
L COSTELLO
2.08.99
MECHANICAL MASTER
02-080
SHEET
M622
JOB N0.
1000673098
COMP N0.
PLANT 2 °wG ND. 02-080-M622
•PERMIT COORD COMO
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG13-087 DATE: 06/18/13
PROJECT NAME: BOEING #2-80
SITE ADDRESS: 8123 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #_
Revision # after Permit Issued
DEPARTMENTS:
O6 `/eV
Building Division
Public Works ❑
3
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
DUE DATE: 06/20/13
Not Applicable ❑
Comments:
Permit Center Use Only ° •
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Pg Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 07/18/13
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only.
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0
Ping ❑ PW ❑
Staff Initials:
Contractors or Tradespeople Per Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with LW to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name DESIGN AIR LTD UBI No. 600314241
Phone 2538542770 Status Active
Address 8657 South 190Th St License No. DESIGL*212DG
Suite/Apt. License Type Construction Contractor
City Kent Effective Date 3/7/1979
State WA Expiration Date 3/7/2014
Zip 98031 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
ther Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
MRCCOL'981J6
M R C
CONSTRUCTION LLC
Construction
Contractor
General
Unused
4/2/2002
4/29/2012
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
HAGEN, RONALD A
President
01/01/1980
Amount
PORTO, MARK M
Secretary
03/08/2010
GL2095787039
MATZ, RICHARD K
Vice President
03/08/2010
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
8
TRAVELERS CAS &
SURETY CO
103742548
03/07/2002
Until Cancelled
$12,000.00
02/28/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
32
Continental Cas
o
GL2095787039
10/01/2012
10/01/2013
$2,000,000.00
10/01/2012
31
Continental Cas
GL2095786635
10/01/2011
10/01/2012
$2,000,000.00
09/30/2011
30
CONTINENTAL
CAS CO
GL2095785243
10/01/2010
10/01/2011
$2,000,000.00
09/27/2010
29
CONTINENTAL
CAS CO
GL2095786232
10/01/2009
10/01/2010
$2,000,000.00
09/25/2009
28
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
27
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
26
CONTINENTAL
CAS CO
GL2095783234
10/01/2007
10/01/2008
$2,000,000.00
09/24/2007
25
CONTINENTAL
CAS CO
HL2079600087
10/01/2006
10/01/2007
$2,000,000.00
10/09/2006
24
CONTINENTAL
CAS CO
GL2079600087
10/01/2006
10/01/2007
$6,000,000.00
10/05/2006
httns://fortress.wa. aov/lni/bbin/Print.asnx
06/21/2013