HomeMy WebLinkAboutPermit PG13-088 - BOEING #2-127 - GAS PIPINGBOEING #2-127
8123 EAST MARGINAL
wys
PG1 3-088
City ai Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No.: 0001600020
Address: 8123 EAST MARGINAL WY S TUKW
Project Name: BOEING #2-127
Permit Number: PG 13-088
Issue Date: 06/21/2013
Permit Expires On: 12/18/2013
Owner:
Name: BOEING COMPANY THE
Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124
Contact Person:
Name: KEN PHILLIPS
Address: 8657 S 190 ST , KENT WA 98031
Email: K.PHILLIPS@DESIGN-AIR.COM
Contractor:
Name: DESIGN AIR, LTD.
Address: 8657 SOUTH 190TH ST , KENT, WA 98031
Contractor License No: DESIGL*212DG
Phone: 253 854-2770
Phone: (253) 854-2770
Expiration Date: 03/07/2014
DESCRIPTION OF WORK:
INSTALL GAS PIPING TO NEW PSE METER
Value of Plumbing/Gas Piping:
Fees Collected:
Electrical Service Provided by:
$12,533.00
$120.75
Permit Center Authorized Signature: 7
I hereby certify that I have read and
governing this work will be complied
Uniform Plumbing Code Edition: 2009
International Fuel Gas Code Edition: 2009
Date:
d this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not presuft"ie to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions
on the back of this permit.
Signature: ,✓}
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date: ✓C �/ j.3
PERMIT CONDITIONS
Permit No. PG 13-088
1: ***PLUMBING AND GAS PIPING***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
rind 1IPC.-4/1rl
PG 13-088 Printed: 06-21-2013
CITY OFTUK., _LA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No.
Project No. Q
Date Application Accepted: 8 13
Date Application Expires: t2-1 t
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
0123
King Co Assessor's Tax No.:
Site Address: Bldg 02-080 Yard lel E Marginal Way South —9tattte7WA Suite Number:
Tenant Name: The Boeing Co.
PROPERTY OWNER
Name: The Boeing Co.
Address: PO Box 3707 M/C 20-00
City: Seattle
State: WA Zip: 98124
CONTACT PERSON — person receiving
communication
Name: Ken Phillips
Address: 8657 S 190th Street
City: Kent
State: WA Zip: 98031
Phone:253.854.2770
Fax:253.854.6131
Email: k.phillips@design-air.com
Oco 1L€
002-o
Floor:
New Tenant: ❑ Yes jg..No
PLUMBING CONTRACTOR INFORMATION
Company Name: Design Air, Ltd.
Address: 8657 S 190th Street
City: Kent State: WA Zip: 98031
Phone: 253.854.2770 Fax: 253.854.6131
Contr Reg No.: DESIGL*212DG Exp Date: 03/07/2014
Tukwila Business License No.: BUS -0101108
Valuation of Project (contractor's bid price): $ 14,720
Scope of Work (please provide detailed information):
Install Gas Piping from point of connection to new Owner Supplied Heater.
Building Use (per Int'l Building Code):
Occupancy (per Int'I Building Code):
Utility Purveyor: Water:
H.\Applications \Forms -Applications On Line \201 1 Applications \Plumbing Permit Application Revised $-9-I I. docx
Revised. August 2011
hh
Sewer:
Page 1 oft
Indicate type of plumbing fixtures and gas piping outlets being installed and the quanipbelow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
i
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
i
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
i
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping system
serving 1-5 inlets/outlets
for a specific gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 Intemational Plumbing Code (current edition).
1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
/37,4,4—,
Signature:
Print Name: Mike Deniger
Mailing Address: 8657 S 190th Street
\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 201 I
bh
Date: 06/.1/ 43
Day Telephone: 253.854.2770
Kent WA 98031
City State Zip
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: httn://www.TukwilaWA.gov
RECEIPT
Parcel No.: 0001600020 Permit Number: PG13-087
Address: 8123 EAST MARGINAL WY S TUKW Status: PENDING
Suite No: Applied Date: 06/18/2013
Applicant: BOEING #2-80 Issue Date:
Receipt No.: R13-01908
Payment Amount: $120.75
Initials: JEM Payment Date: 06/18/2013 01:48 PM
User ID: 1165 Balance: $0.00
Payee: DESIGN AIR
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 97595 120.75
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
GAS - NONRES
PLAN CHECK - NONRES
000.322.103.00.00 96.60
000.345.830 24.15
Total: $120.75
Dr;nre,a• na_1a_�n1z
INSPECTION RECORD
Retain a copy with permit
INSPECT ON NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451 tr-
P6t3_033
Proj t: 't�']
Type oi;lnspectio
1.
Address:
( L...3 E
AL_IMAJ
DateGalled:
Ko -Li 60--
Special Instructions:
Date Wanted:
(P` L,/�P
r%
a��n .
p.m.
Requester:
Pho� Noo ,_2_34.
.... _%
33
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
r
/I
Inspector:
n REINSPECTION FEE REQUIRED:'Puor to next inspection. fee must be
paid at 6300 Southcenter Blvd.te 100. Call to schedule reinspection.
Dat
REQUDRED FOR:
lout
Aitebbanied
®GWSIc
Plumbinj
0 Gas Piping
1 "-MPS
1" -LPC
SEE DETA
ity of Tukwila
LDING DIVISION
C
25'-0" -
SEE 2.YD-M133 FOR CONT.
OF GAS SUPPLY
1/2" PIPING TO SAMPLE
COOLER (TYP), SEE DETAIL
1!
RELIEF
PIPING
DETAIL
1M60 M502
5 BOEING
1M60 M50
ELEV. 2
GROUND
PSE 1M60
6" VENT
THRU ROOF
25'-0"
M503
0
PARATOR
FOR PIPING
SEPARATORS
SEE DETAIL
1M60 M500
2 1/2" -PW, DN
2" PIPING TO SAMPLE
OLER (TYP), SEE DETAILI
1M60
Coil PY
PeInnsilit No.
-v=edjp
Plan r view approval is subject to errors anions.
&pproA'al of construction documents does n•
thy. v ration of any adopted code or ordinanc. .t
of approved Field Copy and •, ���
••�ns is acknowledgai'
0 0 rc!/� i tri
BY
DEW. 6/2///3
SEISMIC
VALVE
-PW, DN
LPC
\-1 1/2"- P
C, DN & PUM
FLOW 4x2
SENSOR
ALVE 3 -
DN
VENT
RU ROOF
PCVi
1M60
SLOP f�
b
j2tUE'\VALVE
(
DETAIR
DETA E�
‘C 1M60 M502
1" -MPS & --
1"-LPC
SEE DETAIL
1M60 M502
1M60 M502
3" -LPC, OVFL
GAS TRAI
THRU Ri
3" -PC LV
DN TOO
4 S-4,
No.1 BOILER
6" -MPS
S-2 /H-1
H-1
0
CENERAL_j O1TEc' {
1M
THRU ROOF
DEAERATOR
& BFW PUMPS
4" -MPS VENT
8" -MPS
ON TO
CO
AS, ON
ON 2 -YD -M13
H-2 ! ECONOMIZER
I \
CHEMICAL INJECTION
SKIDS IU
ECONOMIZER
UST
NCER
RE ERENCE D
NGS
2 1/2" -PW
3" -MPS
ON TO
S-2 W/H-1
2" -_PW DN
6' -PC
0
REV S o
(,gyp cNti ng shall be made to the sma
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional pan review fees.
RLIASON
DATE
SYM
REVISION
81
APPROVED
DATE
RECORD DRAWING
REPLACE BLOWDOWN CONTROLLER
INCREASE NATURAL GAS CAPACITY
J1586456-02
WO/W1405660
10j18286
MGI/CEN
W0B
WDB
06.17.11
11.19.12
2.8.13
3" RPBP
3" -CW, DN
SEE 1M110
1st FLOOR PLAN
SCALE. 1/4"=1'-0"
1" -LPC, DN
TO TRAP
8" -MPS & 6" -PC,
CONT ON 02 -YD -M83 &
02 -YD -M608
gLArAwAvc.
CEaf Oo fu` kwl8L
gUIILDXNG D SXO�I GENERAL NOTES
1 FOR 1/4" CHEMICAL INJECTION TUBING SEE DWG. M312.
EXHAUST SILENCER - PENN SEPARATOR CORP. MODEL
° SP -6-24.
SEISMIC BRACING AND RESTRAINT REQUIREMENTS IN
CONFORMANCE WITH SPECIFICATION 15146 FOR ALL PIPING
ARE THE RESPONSIBIUTY OF THE CONTRACTOR.
4. STEAM AND CONDENSATE PIPE STRESS FOR PIPE ROUTING,
ANCHORS, SUPPORTS AND GUIDES SHOWN ON THE
DRAWINGS ARE WITHIN ASME 831.1 CODE ALLOWABLES FOR
SUSTAINED LOADS DUE TO PRESSURE AND WEIGHT AND
EXPANSION LOADS DUE TO THERMAL GROWTH. SEISMIC
BRACING AND RESTRAINTS ARE THE RESPONSIBILITY OF
THE CONTRACTOR.
0
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 21 2013
City ofT
BUILDING
IV"
'la
SI
•
1" -LPC
SEE DETAIL
1M60 M502 1M60
- TYP SUPPORT
FOR UNIT HEATER
SEE DETAIL
CONSTRUCTION NOTES
ACCEPTABILITY
THIS DESIGN AND/09
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
1M60 M502
RECEIVED
CITY OF TUKWILA
JUN 1 8 2013
DRAWN
MITRED
BREDRNTON
P. TSCHERNEGA
PERMIT CENTER
0810
09.15.08
03.03.09
LSAF Gas project CNT-S-13002
SUBTITLE
M502
1ST FLOOR PLAN - HVAC PIPING
REFERENCE DRAWINGS
02-127-M312
02-127-RFM60
02-127-M505
02-127-M506 PIPE SUPPORTS
CONSTRUCTION NOTES
3- NEW PAD BY BOEING. SEE STRUCTURAL. PIPING
ON PAD BY PSE. OUTLET FLANGE IS BOEING
TIE IN POINT. RUN PIPE HIGH TO GO AROUND
CAGE THEN LOW TO P.O.C. FIELD VERIFY.
RUN NEW WELDED SCHEDULE 40 BLACK PIPE
FROM PSE FLANGE TO EXISTING TIE IN
FLANGE. P.O.C. TO P.O.C. PRIME & PAINT PIPE TO
PROTECT FROM WEATHER.
INSTALL RELOCATED EARTHQUAKE VALVE AND
FLOW METER IN LINE.
' PROVIDE PIPE SUPPORTS SIMILAR AS USED FOR
EXISTING GAS PIPE. THESE ARE WALL MOUNT
STAINLESS STEEL.
SHUT DOWN: PROVIDE BLIND FLANGES AND REMOV
PIPE IN OLD SUPPLY BEFORE NEW LINE ACTIVATIO .
Pad to be constructed by contractor for Boeing
99
EN
CURRT REVISION
ID#18286
SYMBOL B
DATE 2.8.13
C. MAAS
CHEcRED
D. WALTERS
09.15.08
APHHOVkn
03.03.09
APPROVED
B. CYIINN
03.03.09
MECHANICAL MASTER
BUILDING 02-127
COL. A/D-1/3
PLANT2, WA
SHEET
1M60
JOB NO.
586456-02
COMP 110.
DWG NO.
02-127-1M60
111096371: 02/06/13 07:54
ERMiT COORS COMIC
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG13-088
DATE: 06/18/13,
PROJECT NAME: BOEING #2-127
SITE ADDRESS: 8123 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
t;U. C
Building Division
Public Works
64 -0 -
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete vci
Incomplete ❑
DUE DATE: 06/20/13
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route 14 Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 07/18/13
Not Approved (attach comments) ❑
DATE:
Permit. Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials:
Contractors or Tradespeople Pifer Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with LEt1 to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name DESIGN AIR LTD UBI No. 600314241
Phone 2538542770 Status Active
Address 8657 South 190Th St License No. DESIGL*212DG
Suite/Apt. License Type Construction Contractor
City Kent Effective Date 3/7/1979
State WA Expiration Date 3/7/2014
Zip 98031 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
MRCCOL'981J6
M R C
CONSTRUCTION LLC
Construction
Contractor
General
Unused
4/2/2002
4/29/2012
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
HAGEN, RONALD A
President
01/01/1980
Amount
PORTO, MARK M
Secretary
03/08/2010
GL2095787039
MATZ, RICHARD K
Vice President
03/08/2010
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
8
TRAVELERS CAS It
SURETY CO
103742548
03/07/2002
Until Cancelled
$12,000.00
02/28/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
32
Continental Cas
o
GL2095787039
10/01/2012
10/01/2013
$2,000,000.00
10/01/2012
31
Continental Cas
o
GL2095786635
10/01/2011
10/01/2012
$2,000,000.00
09/30/2011
30
CONTINENTAL
CAS CO
GL2095785243
10/01/2010
10/01/2011
$2,000,000.00
09/27/2010
29
CONTINENTAL
CAS CO
GL2095786232
10/01/2009
10/01/2010
$2,000,000.00
09/25/2009
28
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
27
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
26
CONTINENTAL
CAS CO
GL2095783234
10/01/2007
10/01/2008
$2,000,000.00
09/24/2007
25
CONTINENTAL
CAS CO
HL2079600087
10/01/2006
10/01/2007
$2,000,000.00
10/09/2006
24
CONTINENTAL
CAS CO
GL2079600087
10/01/2006
10/01/2007
$6,000,000.00
10/05/2006
httns://fortress.wa.gov/lni/bbin/Print.asnx
06/21/2013