Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG13-097 - THE CONTAINER STORE - ALTERATION
CONTAINER STORE, THE 2437 SOUTHCENTER MALL PG1 3-097 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No.: 9202470010 Address: 2437 SOUTHCENTER MALL TUKW Project Name: CONTAINER STORE, THE Permit Number: PG13-097 Issue Date: 09/17/2013 Permit Expires On: 03/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: SCOTT KANAGA Address: 2805 FAIRMOUNT ST, STE 300 , DALLAS TX 75201 Email: SCOTT.KANAGA@GFF.COM Contractor: Name: WHITING TURNER CONTR CO. THE Address: 300 E JOPPA RD , BALTIMORE MD 21286-3048 Contractor License No: WHITITC099LG Phone: 214 303-1500 Phone: (410) 821-1100 Expiration Date: 09/17/2015 DESCRIPTION OF WORK: TENANT IMPROVEMENT SHALL INCLUDE RESTROOMS AND BREAK ROOM Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: $20,000.00 Uniform Plumbing Code Edition: 2009 $376.69 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: Date: if.//2 3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permi Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ono nn7 Drin4e.1• nC_17.On11 PERMIT CONDITIONS Permit No. PG 13-097 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. r1nr.• L1PC-4/10 PG13-097 Printed: 09-17-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. 1 — 011 Project No. Date Application Accepted: Qty, 7� t/ Date Application Expires: 12 1.t `1 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 262304-9023 Site Address: 2437 Southcenter Blvd Tenant Name: The Container Store Suite Number: 1575 Floor: 1&2 PROPERTY OWNER Name: WEA Southcenter Address: 2800 Southcenter City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Scott Kanaga Address: 2808 Fairmount St, Suite 300 City: Dallas State: TX Zip: 75201 Phone: 214-303-1500 Fax: Email: scott.kanaga@gff.com New Tenant: ❑X Yes CI ..No PLUMBING CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ yov` Uoo Scope of Work (please provide detailed information): -gt,1/.vrr //v// /?—OV i $11.4LL //116Lud65 572?—dC)111Si A ,6f 7+K P-e>om %b,L /2T/4'L STb/e& Building Use (per Int'I Building Code). (6°V6I C M421---) Occupancy (per Int'l Building Code): P16)- 1 fi& Utility Purveyor: Water Sewer H:\Applications\Forms-Applications On Line\201I Applications\Plumbing Permit Application Revised 8-9.11.docx Revised: August 2011 bb Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 2 Shower, single head trap 4 Sinks 1 Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) 1 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 2 Lavatory 4 Urinal 1 Water heater and/or vent Repair or alteration of drainage or vent piping 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty • Clothes washer, domestic Food -waste grinder, commercial 1 Wash fountain Water closet 3 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 3 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO . D AGENT: Signature: Print Name: Mailing Address: 2vU v Date: Day Telephone: 2c • 7Y. 3c/c)3 -/4-- .?$/g o City H:\Applications\Forms-Applications On Line \2011 Applications \Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh State Zip Page 2 of 2 • J���Lq wq City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG 13-097 Address: 2437 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/28/2013 Applicant: CONTAINER STORE, THE Issue Date: Receipt No.: R13-02613 Payment Amount: $301.35 Initials: WER Payment Date: 09/12/2013 01:24 PM User ID: 1655 Balance: $0.00 Payee: WHITING -TURNER CONTRACTING COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0734942 301.35 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 301.35 Total: $301.35 'Inr• Paroinf_f1C. Printari• n4-12_71111 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: 2437 SOUTHCENTER MALL TUKW Suite No: Applicant: CONTAINER STORE, THE RECEIPT Permit Number: PG13-097 Status: PENDING Applied Date: 06/28/2013 Issue Date: Receipt No.: R13-02024 Initials: User ID: JEM 1165 Payment Amount: $75.34 Payment Date: 06/28/2013 10:52 AM Balance: $301.35 Payee: PETE FITZGIBON, BY PHONE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 040135 ACCOUNT ITEM LIST: Description 75.34 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 75.34 Total: $75.34 Drinfori• (1R-914-9(114 INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request. Line (206)431-2451 g.13 -0s 7 Proje Typ of.Inspection: r-. Address: A_Oo4) @_ u" 1I Date Called:. `. Special Instructions: - Date Wanted: :19 1 q W.... -K: - P.m. Requester: . Phone No: .Approved per applicable codes. Corrections required prior to approval. COMMENTS: \P-AAAir>inl • ri INSPECTION FEE REQUI ED. Prior to next inspection, fee must be l t16300 Southcenter Blvd.,`Suite 100. Cali to schedule reinspection: INSPECTION NO. INSPECTION RECORD Retain a copy with permit P' '3-0V1 PERMIT -NO. CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: --r , . ..._:- . a0A�4 &. ASS ( die Type of Inspection: K....0 k)r,N- =s-=�t i G AS Ado -3,7 Date Called: Special Instructions: - e / 1. Date Wanted:/ m Requester: . Phone No: 11Approved per applicable codes. Corrections required prior to approval. COMMENTS: C4- : O U (\:(-3a n i Date: - 1J REINSPECTION FEE REQUIRED. P for to next inspection, fee must be paid at 6300 Southcenter Blvd.. -S ite.100. Call to schedule reinspection: INSPECTION RECORD Retain a copy with permit INSPECTION NO. 136,13-09 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: 0Or- 4//,,Xf .5 7012i Type f Inspection: i<Orj11-ion Address: 2 1"' 3' pk4 4 i 1 Date Called: Special Instructions: /J 13-azz Date Wanted / z%„ /I 3 Requester: I)/I11 No Phone : _ c J7-�-,2 3 R Approved per applicable codes. Corrections required prior to approval. COMMENTS: �.� t/ - O ppiaoef %t4.J Date: / •fZ /1 R INSP CTION FEE REQUIRD. Prior to/next inspection. fee must be p 'd -at 6300.SouthcenterBlvd., Suite .100. Callao schedule reinspection. INSPECTION NO. INSPECTION RECORD -- Retain a copy with permit R53-oF7 PERMIT NO. a10 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro•ect: ch'A l ,i2. 9.1-(0,lcc Ty o Inspe tion: `ri.) Address: 9W21'7 SCtr\AU.- Date Called: Special Instructions: Date Wanted: a.m Reque_sten/ ' - Dt14J Phone No; d-(o(1=GZ36 ElApproved per applicable codes. 0Corrections required prior to approval. COMMENTS: C9-NJit t ' n.j it • Date: ,, .al PU D Prior t`o next inspection, fee must be SPECTION FEE RE IRE p at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ',PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-091 DATE: 06/28/13 PROJECT NAME: THE CONTAINER STORE SITE ADDRESS: 2437 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: uilding Division 1■J 157 RIK-01' 02▪ -'t3 Public Works En Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07/02/13 Complete t Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: LETTER OF COMPLETENESS MAILED: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route' Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/30/13 Approved ❑ Approved with Conditions IX1 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Peer Friendly Page I General/Specialty Contractor A business registered as a construction contractor with LEO to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WHITING TURNER CONTR CO, THE UBI No. 600594886 Phone 4108211100 Status Active Address 300 E Joppa Rd license No. WHITITC099LG -Suite/Apt. License Type Construction Contractor City Baltimore Effective Date 6/7/1991 State MD Expiration Date 9/17/2015 Zip 212863048 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WHITITC145BT WHITING TURNER CNTRNG CO, THE Construction Contractor General Unused 1/30/1986 12/31/1986 Archived Business Owner Information Name Role Effective Date Expiration Date C T CORPORATION SYSTEM Agent 01/01/1980 Bond Amount HACKERMAN, WILLARD President 06/07/1991 9057791 IRISH, CHARLES A Vice President 06/07/1991 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Fidelity & Deposit Ins Co of Maryland 9057791 06/03/2011 Until Cancelled $12,000.00 09/17/2013 3 TRAVELERS CAS & STY CO OF AMER 400KM9671 06/03/2006 Until Cancelled 08/23/2011 $12,000.00 10/05/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 Travelers Indemnity Company Th VTC2JC05788620ATIL13 08/01/2013 08/01/2014 $2,000,000.00 09/17/2013 18 ZURICH AMERICAN INS CO GL0386588107 08/01/2010 08/01/2011 $2,000,000.00 07/20/2010 17 ZURICH AMERICAN INS CO GL0386588106 08/01/2008 08/01/2010 $2,000,000.00 07/31/2009 16 ZURICH AMERICAN INS CO GL03865888104 08/01/2008 08/01/2009 $2,000,000.00 07/23/2008 15 AMERICAN STATES INS CO 01CH55062910 08/01/2007 08/01/2008 $500,000.0007/16/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period httns://fortress. wa. aov/lni/bbip/Print. aspx 09/17/2013 71: co th cst co co 0 El COO 0 0 0 0 F 0 a) En cTi _c 1— co tal 0 co c "cT3 c ET3 Z a_ Z LLI ra PLUMBING PLAN NOTES: 0 CONNECT NEW TENANT 2"CW PIPING TO EXISTING 2"CW MAIN. VERIFY EXACT SIZE AND LOCATION. 0 CONNECT NEW TENANT 4"S PIPING TO EXISTING 4"S MAIN. VERIFY EXACT SIZE AND LOCATION. 0 CONNECT NEW TENANT 2"V PIPING TO EXISTING 3"V MAIN. VERIFY EXACT SIZE AND LOCATION. CONNECT NEW 1-1/4" GAS TO EXISTING 1-1/4" GAS MAIN. COORDINATE THAT GAS METER IS CAPABLE TO SERVICE TENANT'S GAS DEMAND OF 2,160 MBH AT 2LB PRESSURE WITH A TOTAL DEVEPOLED LENGTH OF 400'. GENERAL CONTRACTOR TO CONFIRM HEIGHTS ABOVE CONCRETE FLOOR SLAB FOR ALL EXISTING LINES RUNNING THROUGH THE SPACE AND INCLUDE THESE ON THE COORDINATION DRAWING. w 0 11=910 1212 0 0 0 Ca9 4"S ETR— REVIEWED FOR CODE COMPLIANCE APPROVED JUL 08 2013 (541/ - City of ila BUILDING VISION cLC) ‘.1 N. ro © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM SALES No changes of work w Tukwil NOTE: Revisions and may inclu. REVISIONS hall be made to the scope hout prior approval of a Building Division. wilt require a new plan submittal e additional plan review fees. 1 — 1/4"G ETR to • .... • .......... • " . • . ..... • .... • . • • . • . . . ................ . .. .. . ... ... ...... 3/4"G UP TO ROOF 3/4"CW ETR _ COMM SEPARATE ERMIT REQUIRE FOR: Ect Mich kat 154- ElectricaI 0 PIumbiig Gas big City of T kwila BUILDING DIVISION FILE COPY ft No. ( Plan review approval is toerrorsandomssons. Approval of construction documents does not authorize thc ;:;olation of any adopted code or ordnance. Receipt of approved FieldCopy and •-• --- is By 7in( Date: / City Of Tki BUILDING DIVISION WOMEN 3/4"G UP TO ROOF . . . . . . . . . . . . . JANITO SUPPLY STOCK ROOM 2,335 SF ..... . ......... . . • . . . . ........ . ...... . . . . . . . . . . . . ... ...... . . .... . . .... ...... . . . . . . . . . . ...... . . . . . . . . ...... . . ........ .. . . . . . . ......... . . . .... ..... . . . . . • . . . . . . . . . . . . 1/2"G Ur TO ROOF BREAK ROOM . ..... . ..... . . .... ... . . ... ..... TERRACE . . . . ....... . . . . . . . . . . . . . . .. . . . . . . . . .. . . . .. . . . . . . .................... ' . . . . . . . . . . . . . . . . . . . . . . .. . . . . ......... ' . . '.• . . . • . . . . .. . . .. . . . . -'!1)14)1».41a• STORE MGR. 3/4"3 UP TO F00F . . . . . . .. . . . . .. . . . . . . . . . . . . . . . . . . ..... . . . .... . . ... . ... . . . . . . . . .. . . . . . ...... . . . . . .... . .. . ' . . • . ' .. .... • . ' . ' . . ' . . . ............ . . . ..... . ..... . . . . ...... . . . . ..... . . . . . . . . ...... . . . .... . . . . . . .... . . . . . . . ..•••••••• .. . . . . . . . . . . . . . . . . . . . . ' ... . . . . . . ... . . . . . . . . . .... . . . . . . . . . ... . ...... . . . . . . . ....... . . . . . . . . . . . . . . . .............. . . . . . . . .... . .. . . . . . . . . . . . . . . . . . . . . . .... . . . ... . . . . .... . . . . . . . . . . . . . . . . . . . . . . . . . . ...... . . . .... . . . . . . . . . . .......... . . . . . . . . . . ............. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . .... . . • . .. . . . . . . . . . . . . .. • . . . . . . ............. .. . . .. . . . . . . . . . . GENERAL MANAGER POS/GEN 1 \ / /\ // / \ ..... • • ... ... • • • • ... . • • • • ........ ... • • • . ... • • .. • • . • • • • • • • • • • • . • • . . • • • • • . .... . . . ... . . . . . . . . . . • ... . . . . .. . . . . . .. . . . .. . . . . . ........ . . . . . . . . ........... . . . . . . . . . . . ........... . . . . . . . . . ............. . . . . .. . ...... ........... . . . . . . ... . ' . • . . . . . .. .. . ..... . . . . . . . . ..... . . ......... . . . . . . . . ..... . . . . . ..... . ..... . . ............... . . . . . . . . . . . . . . . REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING — NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J—BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. • ROOF BELOW A. No. Date Drawn Checked Approved Item REVISIONS RECEIVED CITY OF TUKWILA JUN 2 8 26I3 PERMIT CENTER REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. PLUMBING FLOOR PLAN SCALE: 1 /8"= 1 '-0" PC71S4--0111 PLUMBING PLAN Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision P- 1 U U U m a a N 0 N N CDa 3 a NI CO 0 0 0 E a N 0 a) I- 0 0 0 m s I- N co co O O O O m 0 0 I- E = O � oZ a Z y W � Y is 0 W m J dOIS PARKING DECK tat 0 0 mama 0 THEATRE ABOVE STAIRS (TYP) EXTERIOR WALKWAY 3/4"G DOWN 15 TONS 480 MBH 15 TONS 480 MBH 3/4"G DOWN 4 TONS LANDLORD TRASH 3/4"CD 15 TONS 480 MBH 3/4"G DOWN 1-1/4"CD 6 TONS 150 MBH 1-1/4"CD •���1 /2"G DOWN 3/4"CD 15 TONS 480 MBH 3/4"G DOWN HIGH ROOF ROOF BELOW PLUMBING ROOF PLAN SCALE: 1 /8"=1 —0" ROOF BELOW REVIEWED FOR CODE COMPLIANCE APPROVED 3UL 0 8 2013 City of TUOIlia BUILDING p1 VISION PLUMBING PLAN NOTES: 0 TERMINATE CONDENSATE PIPE OVER PRIMARY ROOF DRAIN WITH AIR GAP. COORDINATE PIPE INSTALLATION AND ROUTING OF CONDENSATE DRAIN PIPING WITH LANDLORD AND ALL OTHER TENANT ROOF MOUNTED EQUIPMENT. TOTAL CONNECTED NATURAL GAS LOAD MECHANICAL EQUIPMENT EQUIPMENT DESIGNATION QUANTITY DESCRIPTION MBH (EACH) TOTAL MBH RTU -1,2,3,4 4 ROOF TOP UNIT 480 1920 RTU -6 1 ROOF TOP UNIT 150 150 TOTAL = 2070 NATURAL GAS SYSTEM AS FOLLOWS: TOTAL DEVELOPED LENGTH FROM GAS METER TO MOST REMOTE PIECE OF EQUIPMENT (RTU -4) = 200' AT PRESSURE 2 PSI WITH A DROP OF 1.0 PSI. REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING — NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J—BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. NOTE: ALL NATURAL GAS AND CONDENSATE PIPING ON ROOF SHALL BE SUPPORTED AND SECURED IN ACCORDANCE WITH THE ROOFING MANUFACTURERS INSTRUCTIONS AND APPROVED DETAILS. NOTE: SEAL AND FLASH ALL ROOF PENETRATION AS PER ROOFING MFR. REQUIREMENTS AND SMACNA DETAILS REFERENCED ON ARCHITECTURAL DRAWINGS. ALL ROOF PENETRATIONS TO BE MADE BY ROOFING SUB—CONTRACTOR. NOTE: REFER TO M -1R FOR HVAC ON ROOF AND E -1R FOR POWER ON ROOF. P&roi N CD O N o LO o U OO -To M M N N Fs! � O co O 4' N Ci) 0 0 © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM 0 CO 00 zJJ00 L>_J G O w E Q � 01_ wz U w —I ZOOF LLI (j) (r) V) LO n 0 0 0 0 0 0 0 0 0 0 0 0 0 0 No. Date Item REVISIONS Drawn Checked Approved RECEIVED CITY OF TUKWILA JUN 282013 PERMIT CENTER PLUMBING ROOF PLAN Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision P-1 R PROVIDE THERMOMETER IN TEE FITTING HOT WATER TO FIXTURES --' SHUT-OFF VALVE (TYPICAL) PROVIDE PIPE UNIONS (TYPICAL) ABOVE TOP OF TANK (TO FACILITATE REMOVAL OF WATER HEATER) CONNECT TO TOP OR SIDE OF TANK AS REQUIRED FOR MODEL FURNISHED PROVIDE DIELECTRIC PIPE UNION AT TANK CONNECTION FOR CONNECTION OF DISSIMILAR METALS (TYPICAL) PROVIDE 12"WIDE x 12"DEEP HEAT TRAP AT INLET AND OUTLET (TYPICAL) ELECTRIC WATER HEATER PER SPECIFICATIONS AND SCHEDULE INSTALL DRAIN VALVE FURNISHED WITH WATER HEATER 6" WATERTIGHT PAN UNDER ■ ■ . PROVIDE AUTOMATIC VACUUM RELIEF VALVE ABOVE TOP OF TANK HEATER WITH DRAIN PIPE SET WATER HEATER ON CONCRETE EQUIPMENT PAD PER SPECIFICATIONS COLD WATER SUPPLY TO WATER HEATER COLD WATER TO EXPANSION TANK RECIRCULATION PUMP WITH UNION CONNECTIONS. PROVIDE SHUTOFF VALVE, AQUASTAT AND STRAINER UPSTREAM, CHECK VALVE AND SHUTOFF VALVE DOWNSTREAM TYPICAL CHECK VALVE INSTALL ASME TEMPERATURE AND PRESSURE RELIEF VALVE FURNISHED WITH WATER HEATER PROVIDE HARD COPPER RELIEF VALVE DISCHARGE PIPE FULL SIZE OF VALVE OUTLET. TERMINATE OVER JANITOR'S SINK WITH AIR GAP PER CODE. EXTEND DRAIN PAN LINE AND TERMINATE OVER FLOOR DRAIN WITH AIR GAP PER CODE. REFER TO SPECIFICATIONS, SCHEDULES, AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. VERIFY CONNECTION SIZES AND LOCATIONS WITH WATER HEATER FURNISHED. REFER TO FLOOR PLANS FOR PIPE SIZES AND CONTINUATIONS. PROVIDE SEISMIC STRAP OR BRACING WHEN REQUIRED BY LOCAL AUTHORITIES. POWER WIRING AND DISCONNECT SWITCH ARE SPECIFIED BY ELECTRICAL. INTERLOCK OF AQUASTAT WITH RECIRCULATION PUMP IS SPECIFIED BY ELECTRICAL. COLD WATER MAIN BRANCH PIPE WITH SHUT-OFF VALVE FEEDING PLUMBING FIXTURE(S) AUTOMATIC TRAP PRIMER VALVE WITH INTEGRAL AIR GAP. INSTALL TRAP PRIMER MINIMUM 12" ABOVE FLOOR FOR EVERY 20' OF PRIMER DISCHARGE PIPE. PROVIDE DISTRIBUTION UNIT(S) WHERE MORE THAN ONE TRAP IS SERVED BY ONE TRAP PRIMER VALVE. ONLY INSTALL TRAP PRIMER ABOVE LAY -IN CEILINGS. PROVIDE FLOOR DRAIN BODY OR P -TRAP WITH THREADED TRAP PRIMER CONNECTION. PROVIDE SWEAT TO THREADED ADAPTER. BRAZE JOINT BELOW FLOOR SLAB ON GRADE. ELECTRIC WATER HEATER AND PUMP NO SCALE CONNECT 1/2" PIPE (WITHOUT SHUT-OFF VALVE IN BRANCH) TO TRAP PRIMER VALVE OFF TOP OF BRANCH PIPE. INSULATE PIPE UPSTREAM OF TRAP PRIMER, BUT NOT DOWNSTREAM. INSTALL TRAP PRIMER LINE(S) DOWNSTREAM OF TRAP PRIMER OR DISTRIBUTION UNIT USING 1/2" SOFT COPPER TUBING. INSTALL WITHOUT KINKS, AND SLOPE CONTINUOUSLY TOWARDS FLOOR DRAIN. CONCEAL PIPE(S) IN PARTITION OR CHASE IN FINISHED AREAS. TRAP PRIMER AND PIPES MAY BE INSTALLED EXPOSED IN UNFINISHED, NON-PUBLIC AREAS. IF PIPE IS BELOW FLOOR SLAB ON GRADE, PROVIDE 1/2" ELASTOMERIC INSULATION FROM PRIMER CONNECTION TO 1" ABOVE FLOOR SLAB. PROVIDE TRAP PRIMERS WHERE SHOWN ON FLOOR PLANS, AND WHERE REQUIRED BY LOCAL AUTHORITIES. PIPING ARRANGEMENT SHOWN IS SCHEMATIC: ADJUST TO SUIT FIELD CONDITIONS. REFER TO SPECIFICATIONS AND PLUMBING FIXTURE SCHEDULE FOR MORE INFORMATION. INSTALL TRAP PRIMER VALVE AND DISTRIBUTION UNIT PER MANUFACTURER'S RECOMMENDATIONS. SECURE PIPE HANGER TO STRUCTURE (TYP) THREADED STEEL ROD WITH NUT AND WASHER BOTH SIDES (TYP). CLEVIS HANGER, SHOWN FOR CLARITY. SIZE HANGER FOR COLD PIPE OUTSIDE DIAMETER PLUS INSULATION THICKNESS. DO NOT PENETRATE INSULATION WITH HANGER. PROVIDE A SECTION OF HIGH DENSITY INSULATION OR STYROFOAM BILLETS AT EACH HANGER OF COLD INSULATED PIPE. PROVIDE SHORT INSULATION SHIELD FOR LAPPING INSULATION JACKET OVER HIGH DENSITY INSULATION OR STYROFOAM BILLETS. MAINTAIN VAPOR BARRIER TRAP PRIMER OVERHEAD NO SCALE HOT PIPE REFER TO SPECIFICATIONS FOR INSULATION TYPES, INSULATION THICKNESSES, HANGER TYPES, HANGER ROD CONNECTIONS TO SRUCTURE AND HANGER SPACING. CLEVIS HANGER, SHOWN FOR CLARITY. SIZE HANGER FOR HOT PIPE OUTSIDE DIAMETER. CUT INSULATION TO FIT AROUND HANGER. SEAL EXPOSED INSULATION ENDS WITH JOINT SEALANT INSULATED PIPE HANGER DETAIL NO SCALE INSTANTANEOUS ELECTRIC WATER HEATER PER SPECIFICATIONS AND SCHEDULE, MOUNT TO WALL, UNDER SINK AND BEHIND SKIRT. INSTALL PER MANUFACTURER' S INSTRUCTIONS. DISCONNECT SWITCH IS SPECIFIED BY ELECTRICAL LAVATORY OR SINK AS SHOWN ON PLAN FLEXIBLE RISERS TO FIXTURE FAUCET PER SPECIFICATIONS ANGLE STOP VALVES ON TWO COLD WATER SUPPLIES FINISHED FLOOR REFER TO SPECIFICATIONS, SCHEDULES, AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. VERIFY CONNECTION SIZES AND LOCATIONS PER MANUFACTURER'S REQUIREMENTS, AND INSTALL PER MANUFACTURER'S INSTRUCTIONS. REFER TO FLOOR PLANS FOR PIPE SIZES. INSTALL WATER HEATER CLEAR OF ADA REQUIRED SPACE FOR ADA COMPLIANT LAVATORY OR SINK. PROVIDE T&P RELIEF VALVE ON WATER HEATER OUTLET ONLY IF REQUIRED BY LOCAL AUTHORITIES, AND DISCHARGE WERE DIRECTED BY AUTHORITIES. INSTANTANEOUS WATER HEATER NO SCALE 3/4" PIPE FROM COLD WATER SUPPLY TO WATER HEATER, WITH NO CHECK VALVES INTERVENING FDA -COMPLIANT BUTYL DIAPHRAGM WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, NSF APROVED FOR DOMESTIC WATER SERVICE PIPE HANGER NEXT TO ELBOW PROVIDE DIELECTRIC PIPE UNION AT TANK CONNECTION FOR CONNECTION OF DISSIMILAR METALS AIR CHARGING VALVE. FILL TANK WITH AIR PRESSURE TO MATCH WATER PRESSURE. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. PROVIDE SEISMIC STRAP OR BRACING WHEN REQUIRED BY LOCAL AUTHORITIES. SMALL EXPANSION TANK NO SCALE KEYCURB ADJUSTABLE ROLLER PIPE SUPPORT CARBON STEEL THREADED ROD. (TYP.) 3-1/2" HIGH MOLDED RECYCLED RUBBER CURB NATURAL GAS OR CONDENSATE DRAIN PIPE. REFER TO DRAWINGS FOR PIPE SIZE(S). SET SUPPORT CURB ON BARE ROOFING MEMBRANE, NOT ON AGGREGATE. APPLY SLIP SHEET OR PAD, IF REQUIRED BY ROOFING MANUFACTURER. ROOF INSULATION REFER TO SPECIFICATIONS AND MANUFACTURER'S REQUIREMENTS FOR SPACING. DESIGNED TO SUPPORT PIPING UP TO 4" DIAMETER. PLACE A SUPPORT AS CLOSE AS POSSIBLE TO EACH ELBOW AND TEE. SET SUPPORT CURBS FREE ON BARE ROOFING MEMBRANE NOT TO EXCEED 10' SPACING. ADJUST EACH ROLLER TO ITS DESIRED HEIGHT. CHECK EACH SUPPORT FOR EQUAL WEIGHT DISBURSEMENT. INSTALL PIPE TO ALLOW FOR EXPANSION AND CONTRACTION. ADJUSTABLE ROLLER PIPE SUPPORT ON ROOF NO SCALE! ADAPTER(S) AS REQUIRED TO CONNECT CONDENSATE DRAIN PIPE TO' STUB ON EQUIPMENT. PROVIDE DRAIN PIPE ONE NOMINAL 'PIPE SIZE LARGER THAN EQUIPMENT CONNECTION SIZE, MINIMUM 3/4" PROVIDE TRAP DEPTH GREATER OF 4" OR 1/2" PLUS STATIC PRESSURE IN INCHES OF WATER COLUMN 6" TALL VENT OPEN TO ATMOSPHERE ONLY WHERE REQUIRED BY CODE FOR LENGTH OF DRAIN PIPE GAS FIRED ROOF -TOP AIR CONDITIONING UNIT OR MAKEUP AIR UNIT PER MECHANICAL PLANS DISCHARGE AWAY FROM SERVICE AREAS OF UNIT, OR AT ROOF DRAIN OR GUTTER IF REQUIRED BY LOCAL AUTHORITIES OR SHOWN 'ON PLANS - SUPPORT PIPE ON ROOF PER SPECIFICATIONS LJ i O PIPE REDUCED FROM BRANCH PIPE SIZE TO UNIT CONNECTION SIZE, AT UNIT CONNECTION STUB GENERAL NOTES: 1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE TO OBSERVE THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. FURNISH A CONSTRUCTION RECORD SET OF "AS -BUILT" DOCUMENTS TO THE ARCHITECT REFLECTING ANY VARIANCES OF INSTALLED PIPING LOCATIONS OR EQUIPMENT CONTRARY TO THE CONSTRUCTION DOCUMENTS PREPARED BY THE ENGINEER -OF -RECORD AFTER FINAL INSPECTION OF INSTALLED PLUMBING SYSTEMS. 3. FURNISH TO THE ARCHITECT A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS. 4. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE LANDLORD. 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE START OF PROJECT. 7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES. 8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING. 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. 10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO STRUCTURE. INSTALL TEE TEN PIPE DIAMETERS MINIMUM DOWNSTREAM OF PRESSURE REGULATOR, IF REGULATOR SHOWN ON PLANS GROUND JOINT PIPE UNION GAS PRESSURE REGULATOR IF SHOWN ON PLANS, RE: SCHEDULES, AND SPECIFICATIONS GAS COCK FULL SIZE OF BRANCH PIPE. REFER TO PLAN FOR SIZE OF BRANCH PIPE BRANCH OFF TOP OF GAS PIPE MAIN. REFER TO PLANS FOR PIPE SIZES - ARRANGE PIPE AND ELBOWS TO ALLOW FOR EXPANSION AND CONTRACTION OF PIPE RUNS LINE SIZE TEE, EXIT THRU SIDE OUTLET 3" LONG LINE SIZE DIRT LEG WITH BOTTOM MINIMUM 3-1/2" MINIMUM ABOVE ROOF ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. PROVIDE CONNECTIONS SHOWN IN EQUIPMENT MANUFACTURER'S INSTALLATION INSTRUCTIONS. VERIFY CONNECTION LOCATIONS BEFORE INSTALLING PIPE RUNS. REFER TO SPECIFICATIONS FOR PIPE AND FITTING MATERIALS AND INSTALLATION. PROVIDE DIELECTRIC UNION IF CONNECTING DISSIMILAR METALS. FOR PIPE SIZE(S) REFER TO FLOOR PLANS, OR CODE REQUIREMENTS FOR HVAC UNIT TONNAGE. PROVIDE GAS COCK, UNION AND DIRT LEG SAME SIZE AS BRANCH PIPE. SLOPE CONDENSATE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE, 2% MINIMUM. PROVIDE CLEANOUTS IN ENDS AND TURNS OF PIPE PER LOCAL CODE REQUIREMENTS: ADAPTER WITH THREADED CLEANOUT PLUG. OMIT CONDENSATE DRAIN ON MAKEUP AIR UNIT. PROVIDE MINIMUM 6" CLEARANCE TO ROOF UNDER PIPES. 61 CONNECTIONS TO ROOF -TOP UNIT 1 NO SCALE 11. NO PLASTIC PIPE SHALL BE INSTALLED IN THE CEILING RETURN AIR PLENUM. 12. COORDINATE ALL ,WORK WITH OTHER TRADES AND CONTRACTORS. 13. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED. 14. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE OWNER. 15. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. 16. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE PIPING OVER ELECTRICAL PANELS. 17. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. ALL ROOF PENETRATIONS TO BE MADE BY LANDLORD'S ROOFING CONTRACTOR. 18. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH MINIMUM 2" BATT INSULATION TO PREVENT FREEZING. 19. PROVIDE SHIELDED ADAPTER COUPLINGS FOR CONNECTION OF PVC DWV TO CAST IRON AT SLAB ON GRADE. SEE DIVISION 15 SPECIFICATION SECTION "DRAINAGE AND VENT SYSTEMS" FOR MORE INFORMATION. 20. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 21. PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLIES FOR MOP SINK FAUCETS DOWNSTREAM OF SHUTOFF VALVES. PLUMBING FIXTURE SCHEDULE: FIXTURES IN THIS SCHEDULE ARE PROVIDED BY THE PLUMBING CONTRACTOR. NO SUBSTITUTIONS ARE ALLOWED. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION AND INSTALLATION REQUIREMENTS. VERIFY ROUGH -IN REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE PLUMBING FIXTURE MOUNTING HEIGHTS. EXPANSION TANK: AMTROL "THERM-X-TROL" # ST -5, WELDED STEEL PRESSURE TANK, POLYPROPYLENE LINING, FLEXIBLE BUTYL DIAPHRAGM, AIR CHARGING VALVE, 150 PSI MAXIMUM WORKING PRESSURE, 2.0 GALLON CAPACITY, 0.45 MAXIMUM ACCEPTANCE FACTOR, 3/4" PIPE CONNECTION. SET THE AIR CHARGE PRESSURE TO MATCH EXISTING WATER SYSTEM PRESSURE. ® ELECTRIC WATER COOLER (ADA ACCESSIBLE): HALSEY TAYLOR # HAC8FSBL-WF-Q ADA WALL -MOUNTED, BARRIER FREE, DUAL - LEVEL, FRONT AND SIDE PUSH ACTUATOR BARS, STAINLESS STEEL BOWL, FLEXIBLE POLYESTER ELASTOMER SAFETY BUBBLER AND STAINLESS STEEL FRONT AND SIDES, CHILLER WITH 8.8 GALLONS PER HOUR CAPACITY, 50° F DRINKING WATER AT 80' F INLET TEMPERATURES 90' F ROOM TEMPERATURE. TRIM: McGUIRE #LF 2165CC COMPRESSION ANGLE STOP VALVE WITH RISER AND ESCUTCHEON; McGUIRE # 8872CF 1-1/4" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P -TRAP AND WASTE ARM WITH CLEANOUT PLUG AND ESCUTCHEON; AND SUITABLE CARRIER WITH STANCHIONS TO FLOOR. ELECTRICAL REQUIREMENTS: 120 -VOLT, 4.0 FULL LOAD AMPS. (PD -1) FLOOR DRAIN: SHULUTER KERDI-DRAIN # KD2/PVC/E WITH STAINLESS STEEL SQUARE GRATE (E 304); OUTLET SIZE AS SHOWN ON PLANS. REFER TO A -DRAWINGS FOR CONNECTION TO BONDED WATERPROOF MEMBRANE IN FLOORING. (GD) FOOD WASTE DISPOSER: INSINKERATOR BADGER 1, 120 VOLTS, 1/3 HP MOTOR, 60 HZ, 1725 RPM WITH GALVANIZED STEEL GRINDING ELEMENTS WITH TWO STAINLESS STEEL 360' SWIVEL LUGS. SELF-SERVICE WRENCH. ELECTRICAL REQUIREMENTS: 120 VOLTS, 7.2 AMPS. JANITOR'S SINK: KOHLER "WHITBY" # K-6710, 28" x 28" x 13"OA BASIN DIMENSION, CAST IRON SERVICE SINK WITH ACID RESISTANT ENAMEL FINISH WITH COATED WIRE RIM GUARD (K-8940) AND 3" IPS STRAINER (K-9146). FAUCET: CHICAGO FAUCET # 897 -CP FAUCET WITH WALL BRACE, INTEGRAL VACUUM BREAKER & STOPS, PAIL HOOK, AND 3/4" MALE HOSE THREADED OUTLET; EQUIP WITH MODEL # 369 HANDLES. SECURE FAUCET IN WALL WITH BACKBOARD. ( LAV) COUNTER TOP LAVATORY (ADA ACCESSIBLE): KOHLER # K- 2354-1 "PING -YANG", SINGLE HOLE, WITH OVERFLOW, COLOR: WHITE, SET IN BED OF SILICONE SEALANT. FAUCET TOTO TEL5LS10#CP SINGLE SUPPLY FAUCET WITH CONTROLLER/MIXER #TN78-10V710 TEMPERATURE MIXER FOR HOT & COLD WATER SUPPLY CONNECTION. HYDROPOWER SELF -GENERATING SYSTEM, AUTOMATIC INFRARED SENSOR ACTIVATED. TRIM: McGUIRE # 155A GRID DRAIN WITH TAILPIECE; McGUIRE #LF BV2165CCLK LOOSE KEY COMPRESSION, ANGLE STOP, QUARTER TURN BALL VALVES WITH RISERS AND ESCUTCHEONS; McGUIRE # 8902CF 1-1/4"-1-1/2" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P -TRAP AND WASTE ARM WITH CLEANOUT PLUG AND ESCUTCHEON; COORDINATE OPENING IN COUNTERTOP WITH LAVATORY DIMENSIONS. RH ) ROOF NON -FREEZE POST HYDRANT: JR SMITH # 5910-19 FREEZE PROOF POST HYDRANT WITH ALUMINUM WEATHER CASING GUARD, T -HANDLE, 3/4" HOSE CONNECTION, DRAIN HOLE CONNECTION. RP) RECIRCULATION PUMP: BELL & GOSSETT # NBF-9U WET ROTOR TYPE INLINE PUMP WITH 2800 RPM MOTOR, LEAD FREE BRONZE BODY WITH UNION CONNECTIONS, CAPACITY OF 2 GPM AT 7 FEET OF HEAD. PROVIDE WITH HONEYWELL #L6006C SURFACE MOUNTED AQUSTAT WITH SINGLE POLE DOUBLE THROW SWITCH FOR CIRCULATOR CONTROL AND ADJUSTABLE DIFFERENTIAL SET TO 10F. SET AQUASTAT TO SHUT OFF RECIRCULATION PUMP AT WATER HEATER SET POINT AND ON AT 1OF BELOW SET POINT. ELECTRICAL REQUIREMENTS: 120 -VOLT, 0.4 FULL LOAD AMPS. SINK: ELKAY, LRAD(Q) 2521, 3 HOLE, OFF CENTER REAR DRAIN HOLE, 25" x 21" x 4" DEEP, SINGLE COMPARTMENT, SELF -RIMMING, TYPE 304, 18-8 GAUGE NICKEL BEARING STAINLESS STEEL, FIXTURE WITH FAUCET LEDGE & 3 HOLES (4" O.C.). SET IN BED OF PUTTY. FAUCET: KOHLER TRITON/FINESSE # K -7313K, LEAD FREE 8" SPREAD FAUCET WITH # K-16012-5 TRITON WRISTBLADE LEVER HANDLES, 1.5 GPM VANDAL -RESISTANT WATER -GUARD AERATOR. TRIM: McGUIRE #LF 2165CC WHEEL HANDLE ANGLE STOP VALVES WITH RISERS AND ESCUTCHEONS; JUST # J-35 BASKET STRAINER WITH 1-1/2" 17 GAUGE TAILPIECE; McGUIRE # 8912CF 1-1/2" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P -TRAP WITH BRASS CLEANOUT AND ESCUTCHEON. COORDINATE OPENING IN COUNTERTOP WITH SINK DIMENSIONS. REFER TO A -DRAWINGS FOR REQUIRED ADA PROTECTION OF PIPING (IF REQUIRED). ( TP ) TRAP PRIMER: PRECISION PLUMBING PRODUCTS # PR -500 "PRIME RITE", CORROSION RESISTANT BRASS BODY, "0" RING SEALS, 1/2" INLET AND OUTLET, AND INTEGRAL VACUUM BREAKER. INSTALL THE VALVE AT A MINIMUM OF 12" ABOVE FINISHED FLOOR. PROVIDE WITH DISTRIBUTION # DU -2 FOR TWO, # DU -3 FOR THREE, OR # DU -4 FOR FOUR DRAIN CONNECTIONS. CONTRACTOR SHALL INSTALL TRAP PRIMER ABOVE LAY -IN CEILINGS ONLY. ( UR ) URINAL (ADA ACCESSIBLE): TOTO MODEL # UT104EV .5 GPF LOW CONSUMPTION WASHOUT URINAL, #01 COTTON FINISH VITREOUS CHINA FIXTURE, 3/4" BACK SPUD INLET, AND WASHOUT FLUSH ACTION. VALVE: ECOPOWER MODEL # TEU2LN11#SS 0.5 GALLON PER FLUSH TRIM: PROVIDE SUITABLE FIXTURE CARRIER WITH STANCHIONS TO FLOOR, J.R. SMITH MODEL 0636. WALL -MOUNTED WATER CLOSET: TOTO #CT708EG #01 COTTON FINISH VITREOUS CHINA FIXTURE WITH ELONGATED BOWL, 1.28 GALLON PER FLUSH, AND SIPHON JET ACTION. VALVE: TOTO #TET1 LN32#CP ECO -POWER" WATER TURBINE AND BATTERY POWERED, 1.28 GALLON PER FLUSH, EXPOSED, CHROME - PLATED, SENSOR OPERATED PISTON TYPE FLUSH VALVE MECHANICAL OVERRIDE PUSH BUTTON, WITH BRASS PISTON WITH CHLORAMINE RESISTANT SEAT AND SEALS AND SELF-CLEANING MECHANISM, ESCUTCHEON, INTEGRAL SCREWDRIVER STOP, VACUUM BREAKER, AND SWEAT ADAPTER KIT. TRIM TOTO #SC534 OPEN -FRONT CONTOURED, SOLID PLASTIC, HEAVY DUTY, SEAT LESS COVER WITH SELF-SUSTAINING CHECK HINGES (11" BEYOND VERTICAL) AND STAINLESS STEEL BOLTS. PROVIDE SUITABLE FIXTURE CARRIER, J.R. SMITH MODEL 0210 OR 0230 ADJUSTABLE CARRIER. ® WALL -MOUNTED WATER CLOSET (ADA ACCESSIBLE): SAME AS WC -1, EXCEPT SET FIXTURE SO THAT RIM HEIGHT IS 17" A.F.F. PER ADA REQUIREMENTS AND INSTALL HANDLE ON WIDE SIDE OF STALL. (WCO) WALL CLEANOUT: JAY R. SMITH # 4530S, CAST IRON CLEANOUT TEE, COUNTER SUNK PLUG, WHITE VINYL ROUND COVER AND SCREW, AND IRON PLUG WITH GASKET SEAL. CLEANOUT COVER SHALL BE 12" ABOVE FINISHED FLOOR, ON CENTER. REFER TO SPECIFICATIONS FOR INSTALLATION. (WHA) WATER HAMMER ARRESTER: PRECISION PLUMBING PRODUCTS, HARD DRAWN COPPER BODY WITH WROUGHT COPPER FITTINGS, PISTON TYPE WITH LUBRICATED EPDM "0" RING SEALS, ASSE 1010 CERTIFICATION. PROVIDE PDI SIZES "A" THROUGH "F" AS SHOWN ON PLANS. PROVIDE SIZE "A" UNLESS SHOWN OTHERWISE ON THE PLANS. WATER HEATER: A.O. SMITH # DEL -20, 20 GALLON GLASS LINED STORAGE TANK, ONE 4KW DIRECT -IMMERSION HEATING ELEMENT, SURFACE -MOUNTED THERMOSTATS, ANODE ROD, T & P VALVE, AND 20 GALLONS PER HOUR RECOVERY AT A 80 DEGREE TEMPERATURE RISE. SET WATER HEATER OPERATING TEMPERATURE TO 120 'F. ELECTRICAL REQUIREMENTS: 277 VOLT SINGLE PHASE, 14.4 FULL LOAD AMPS. REVIEWED FOR CODE COMPLIANCE CE AR JUL 0 8 2013 City of Tukwila BUILDING DIVISION PLUMBING SYMBOLS NOTE: THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. ANNOTATION PIPING O 1 PLUMBING PLAN NOTE CALLOUT PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER SECTION CUT DESIGNATION STANDARD MOUNTING HEIGHTS PLUMBING (AFF, AFG, UNLESS NOTED OTHERWISE) REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. UNO, INSTALL PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOW WITH FINAL APPROVAL BY THE ARCHITECT. ADA ACCESSIBLE DRINKING FOUNTAIN ADA ACCESSIBLE LAVATORIES ADA ACCESSIBLE SHOWER VALVES ADA ACCESSIBLE TUB VALVES ADA ACCESSIBLE URINALS ADA ACCESSIBLE WATER CLOSET ADA ACCESSIBLE WATER COOLER ADULT STANDARD DRINKING FOUNTAIN ADULT STANDARD WATER COOLER CHILD STANDARD DRINKING FOUNTAIN CHILD STANDARD WATER COOLER CHILD URINAL CLINIC SERVICE SINKS JANITOR'S SINK FAUCET FITTINGS HOSE BIBBS ICE MAKER OUTLET BOXES LAVATORY OR SINK NON FREEZE HYDRANT SHOWER HEADS SHOWER VALVES STANDARD URINALS SURGEON'S SCRUB -UP SINKS TUB VALVES WASHING MACHINE OUTLET BOXES WATER CLOSET 17" FLOOR TO RIM 34" FLOOR TO RIM 38" MINIMUM TO 48" MAXIMUM FLOOR TO CENTERLINE CENTER BETWEEN GRAB BAR AND ,TUB RIM 17" FLOOR TO RIM 17" TO `19" FLOOR TO TOP OF SEAT 35" FLOOR TO RIM 41" FLOOR TO RIM 41" FLOOR TO RIM 30" FLOOR TO RIM 30" FLOOR TO RIM 14" FLOOR TO RIM 30" FLOOR TO RIM 42" FLOOR TO CENTERLINE 36" AFF TO CENTERLINE 24" FLOOR TO CENTER OF BOX 31" FLOOR TO RIM 18" AFG TO CENTERLINE 6'-6" MEN & 6'-0" WOMEN FLOOR TO CENTERLINE 48" MEN & 42"WOMEN FLOOR TO CENTERLINE 22" FLOOR TO RIM 35" FLOOR TO FRONT RIM 32" FLOOR TO CENTELINE 42" FLOOR TO RIM 15" FLOOR TO RIM ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AHU AIR HANDLING UNIT BFF BELOW FINISHED FLOOR BFG BELOW FINISHED GRADE BOP BOTTOM OF PIPE BOS BOTTOM OF STRUCTURE BTU BRITISH THERMAL UNIT CPVC CHLORINATED POLYVINYL CHLORIDE DN DOWN DFU DRAINAGE FIXTURE UNIT DS DOWNSPOUT EXISTING TO REMAIN ELECTRIC WATER COOLER ETR EWC FD FFA FFB FF FL FLA FLR GPM HD IE IN WC JB J -BOX kW MAU MAX MBH FLOOR DRAIN FROM FLOOR ABOVE FROM FLOOR BELOW FINISHED FLOOR FLOW LINE FULL LOAD AMPS FLOOR GALLONS PER MINUTE HEAD, HUB DRAIN INVERT ELEVATION INCHES OF WATER COLUMN JUNCTION BOX JUNCTION BOX KILOWATT MAKE-UP AIR UNIT MAXIMUM 1000 BTU PER HOUR MH MIN N/C N/O NORMALLY OPEN ORD PDI PVC PRV RD RPM RTU SF MANHOLE MINIMUM NORMALLY CLOSED OVERFLOW ROOF DRAIN PLUMBING DRAINAGE INSTITUTE POLYVINYL CHLORIDE PRESSURE REDUCING VALVE ROOF DRAIN REVOLUTIONS PER MINUTE ROOFTOP UNIT SQUARE FEET, SUPPLY FAN SP SUMP PUMP SS STAINLESS STEEL, SANITARY SEWER, SOIL STACK TDH TOTAL DYNAMIC HEAD TFA TO FLOOR ABOVE TFB TO FLOOR BELOW TYP TYPICAL UL UNDERWRITERS LABORATORIES, INC. UNO UPS V VOLT(S) VCP VITRIFIED CLAY PIPE VS VENT STACK VTR VENT THROUGH ROOF UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY w/ w/o WC WS WSFU WITH WITHOUT WATER COLUMN WASTE STACK WATER SUPPLY FIXTURE UNIT REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM1.20 AND AV1.10 FOR ADDITIONAL SCOPE. SCW 140' T S - S- W - W- GW - --GW--- ST - - - -ST- - - - OST - - -VBG- - ---VBFID CDH CD ACD SPD G MPG - - -MPG- - - NPW LPG WS FP PD V AW ----AWAV CA Al MA MV VE EV CO N 0 „NO DOMESTIC COLD WATER (CW) SOFTENED COLD WATER (SCW) DOMESTIC HOT WATER (HW) DOMESTIC HOT WATER RECIRC. (HWR) 140' DOMESTIC HOT WATER (140') TRAP PRIMER LINE (T) SOIL PIPING - ABOVE FLOOR (S) SOIL PIPING - BELOW FLOOR (S) WASTE PIPING - ABOVE FLOOR (W) WASTE PIPING - BELOW FLOOR (W) GREASE WASTE - ABOVE FLOOR (GW) GREASE WASTE - BELOW FLOOR (GW) STORM DRAIN - ABOVE FLOOR (ST) STORM DRAIN - BELOW FLOOR (ST) OVERFLOW STORM DRAIN - ABOVE FLOOR (OST) VENT BELOW GRADE (VBG) VENT BELOW FLOOR (VBF) INDIRECT DRAIN (ID) CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH) CONDENSATE DRAIN (CD) AUXILIARY CONDENSATE DRAIN (ACD) SUMP OR SEWAGE PUMP DISCHARGE (SPD) NATURAL GAS (G) NATURAL GAS ON ROOF (G) MEDIUM PRESSURE NATURAL GAS (MPG) MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) NON POTABLE WATER (NPW) LIQUIFIED PETROLEUM GAS (LPG) WATER SERVICE (WS) FIRE PROTECTION (FP) CONDENSATE PUMP DISCHARGE (PD) EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN VENT PIPING (V) ACID WASTE - ABOVE FLOOR (AW) ACID WASTE - BELOW FLOOR (AW) ACID VENT (AV) COMPRESSED AIR (CA) MEDICAL AIR INTAKE (Al) MEDICAL AIR (MA) MEDICAL VACUUM (MV) MEDICAL VACUUM EXHAUST (VE) EVACUATION (EV) CARBON DIOXIDE (CO) NITROGEN (N) OXYGEN (0) NITROUS OXIDE (NO) OXYGEN OUTLET NITROUS OXIDE OUTLET MEDICAL AIR OUTLET NITROGEN OUTLET MEDICAL VACUUM INLET SQUARE FLOOR DRAIN (FS), SIZE & TYPE ROUND FLOOR DRAIN (FD), SIZE & TYPE ROOF DRAIN (RD), SIZE & TYPE BALL VALVE CONTROL VALVE SHUTOFF VALVE CHECK VALVE BALANCING VALVE WITH PRESSURE PORTS WATER METER Iyl STRAINER ISI STRAINER WITH BLOWOFF *Q- RELIEF/SAFETY VALVE D%1 SOLENOID VALVE PRESSURE REDUCING VALVE DlP4 GAS PRESSURE REGULATOR dEl THERMOSTATIC MIXING VALVE PA PIPE ANCHOR EJ EXPANSION JOINT BACKFLOW PREVENTER 4 PRESSURE GAUGE THERMOMETER UNION FLANGE CONNECTION HOSE BIBB (HB) II NONFREEZE WALL HYDRANT (NW) MANUAL / AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE CLEANOUT CAP 3-11 WALL CLEANOUT (WCO) FLOOR CLEANOUT (FCO) ❑o EXTERIOR CLEANOUT (ECO) ELBOW UP ELBOW DOWN Ia TEE UP I'I TEE DOWN IQ ELBOW UP WITH SHUT-OFF VALVE (SOV) +� ELBOW DOWN WITH SHUT-OFF VALVE (SOV) ISI TEE UP WITH SHUT-OFF VALVE (SOV) ISI TEE DOWN WITH SHUT-OFF VALVE (SOV) WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D, & E) RECIRCULATION PUMP Oo P -TRAP ITL GAS COCK a TRAP PRIMER ao TRAP PRIMER WITH DISTRIBUTION UNIT Io FIXTURE BRANCH CONNECTION SCHEDULE FIXTURE COLD WATER HOT WATER WASTE VENT WATER CLOSET 1-1/4" -- 4" 2" URINAL 1" -- 2" 2" LAVATORY/ HAND SINK 1/2" 1/2" 2" 1-1/2" DRINKING FOUNTAIN 1/2" -- 2" 1-1/2" JANITOR'S SINK 1/2" 1/2" 3" 2" FLOOR DRAIN -- -- 3" 2" SINK 1/2" I 1/2" 2" 2" NOTE: PIPE SIZES SHOWN ARE MINIMUM. PG i•-.097 a) s 0 Li) co Lk. 0 2808 Fairmount Street O N N vi CO D © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM J I- CO c W Q J V 00 W O) Of Q a_z�� LLJ W U z�I- Z OO O LiJ UJ () (f) No. Date Item REVISIONS Drawn . RECEIVED CITY OF TUKWILA Checked JUN 2 8 2013 Approved PERMIT CENTER PLUMBING DETAILS, NOTES, LEGEND, & SCHEDULES Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision P- 3