Loading...
HomeMy WebLinkAboutPermit PG13-102 - NORDSTROM - ALTERATIONNORDSTROM 100 SOUTHCENTER MALL PG13-102 City oiR'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROM Permit Number: PG13-102 Issue Date: 08/20/2013 Permit Expires On: 03/26/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: DUNCAN OSBORN Address: 1600 7 AV #2500 , SEATTLE WA 98101 Email: DUNCAN.F.OSBORN@NORDSTROM.COM Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA 98071 • Contractor License No: AUBURMI163BA Phone: 206 454-5553 Phone: (253)838-9780 Expiration Date: 09/12/2014 DESCRIPTION OF WORK: EXTEND GAS LINE TO NEW COOKING EQUIPMENT, ADD FLOOR DRAIN WITH PRIMER, ADD CW/HW TO 3 -COMPARTMENT SINK, AND RELOCATE FAUCET AT SOUP KETTLE. REVISION #1: ADD HANDSINK Value of Plumbing/Gas Piping: $15,000.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $283.63 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied in 'th, Date: lo�o3lf3 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. /ij Signature: V"� Date: to/3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Print Name: nn, o 4 nn Drinfe -4• 1 n_rva_ )A1 • • PERMIT CONDITIONS Permit No. PG 13-102 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG13-102 Printed: 10-03-2013 Parcel No.: Address: City ofIbukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 9202470010 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROM Permit Number: Issue Date: Permit Expires On: PG13-102 08/20/2013 02/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: Address: Email: DUNCAN OSBORN 1600 7 AV #2500 , SEATTLE WA 98101 DUNCAN.F.OSBORN@NORDSTROM.COM Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA 98071 Contractor License No: AUBURMI163BA Phone: 206 454-5553 Phone: (253)838-9780 Expiration Date: 09/12/2014 DESCRIPTION OF WORK: EXTEND GAS LINE TO NEW COOKING EQUIPMENT, ADD FLOOR DRAIN WITH PRIMER, ADD CW/HW TO 3 -COMPARTMENT SINK, AND RELOCATE FAUCET AT SOUP KETTLE. Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: $15,000.00 Uniform Plumbing Code Edition: 2009 $220.63 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: I hereby certify that I have read and ex governing this work will be complied ine th, w Date: DetIq/DII� this permit and know the same to be true and correct. All provisions of law and ordinances ther specified herein or not. The granting of this permit does not pres construction or the performance of work. I on the back of this permit. Signature: Print Name: give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions 9--oSS �artir� Date: v/'213' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Dr 11.1x» Printori• nA_9n_9m1 PERMIT CONDITIONS Permit No. PG13-102 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 12: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG13-102 Printed: 08-20-2013 CITY OF TUIAA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hltp://www,TukwilaWA.gov . - PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" Site Address: /00 S V 112#C63(045e /140944. Tenant Name: it/06tA$?*0A4 Name: kif 571 5 v PA6rAi fax. c• OJOS 1-7=145t2) Address: //,p, Allisitivito vi /it* de -44 Co' 4 -os Anikortrista44 Zip:700 a. 4It,iii0Uiiii_'.':'Y'..T'' Name: Dii,vc.,4Al ose.A/ Address: f0 t, _ 0 77'A -V9 420o City: seArrita State: v14 Zip:cip 0 i Phone:1010 , 1.15.1.5-z.....3 Fax: zap. 4 rsc . i 211 EinailjiAMCah .4: OSk° rt..% go w oris+ry $41* C4 King Co Assessor's Tax No.: fZoz 417 -0/30 Suite Number: 14 f4 Floor: 3 New Tenant: 0....Yes ....Noe . - Valuation of Project (contractor's bid price): $ /5.50(10. Scope of Work (please provide detailed information): Cje)sib 0.45 4/NO 70 Al ew copkbit eat/A/o/a: 44) ri-eoe. bie.,414/ 421.76727 Gainha "V 3 commeisorv- sm4c, Recoo4rar sr? we' Aegsitr. Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): _F42 RiOntisoAr Utility Purveyor: Water: 74144b41- Sewer: 71/414, HAApplications‘Fonns-Applicalkms On Una 2011 Applicatlnes‘PlumbIng Permit Application Revised 8-9-11.doca Revised: August 2011 bh Page 1 of 2 Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: . - Valuation of Project (contractor's bid price): $ /5.50(10. Scope of Work (please provide detailed information): Cje)sib 0.45 4/NO 70 Al ew copkbit eat/A/o/a: 44) ri-eoe. bie.,414/ 421.76727 Gainha "V 3 commeisorv- sm4c, Recoo4rar sr? we' Aegsitr. Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): _F42 RiOntisoAr Utility Purveyor: Water: 74144b41- Sewer: 71/414, HAApplications‘Fonns-Applicalkms On Una 2011 Applicatlnes‘PlumbIng Permit Application Revised 8-9-11.doca Revised: August 2011 bh Page 1 of 2 • • indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: •P.I tureIjPe•; • ' • . Qty, • Bathtub or combination bath/shower �,( PC Dishwasher, domestic with independent drain v Shower, single head trap 0 Sinks (3 • GbMr) 1 Rain water system — per drain (inside building) 0' Grease interceptor for commercial kitchen (>750 gallon capacity) ,�( j(� Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vaciAlm breakers not included in • lawn sprinkler backflow protections (1.5) `m a zroreType Qty.: Bidet ,r( Drinking fountain or water cooler (per head) •• 0 Lavatory 0 • Urinal i 0 Water heater and/or vent 0' Repair or alteration of water piping and/or water treatment equipment ,y( j� Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 0 Fixture Type . • l2t) . . Clothes washer, domestic it( t(� Food -waste grinder, commercial Wash fountain 0 Water closet Industrial waste treatment•interceptor, including trap and vent, except for kitchen type grease interceptors fs Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 0 4 PtfttireType .• Qty` Dental unit, cuspidor �I/ Floor dram Receptor, indirect waste 0 Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific •gas Each lawn sprinkler system on any one meter including backflow protection devices 0 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: '717RIZED AGENT: Print Name: LI/1% ('4N Q aefi Mailing Address: /6 a D 7 71' fi/ 2 5-0 v H: AppticstionsWorms•Applicstions On Unel2011 ApplicedooNIumbing Permit Appliestion Revised 8-9-1l.docx Revised: Augurs 2011 ba Date: //g Day Telephone: 2 0 b ' S E4— W' %'R/ of City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 9202470010 Address: Suite No: Applicant: NORDSTROM 100 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: PG13-102 ISSUED 07/16/2013 08/20/2013 Receipt No.: R13-02505 Initials: WER User ID: 1655 Payment Amount: $63.00 Payment Date: 08/29/2013 01:38 PM Balance: $0.00 Payee: AUBURN MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. ACCOUNT ITEM LIST: Description 0011765 63.00 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 Total: $63.00 63.00 'Inr• R.rcin}-(1R Printed: 08-29-2013 f City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG 13-102 Address: 100 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/16/2013 Applicant: NORDSTROM Issue Date: Receipt No.: R13-02147 Initials: User ID: JEM 1165 Payment Amount: $220.63 Payment Date: 07/16/2013 01:14 PM Balance: $0.00 Payee: DUNCAN OSBORN, NORDSTROM INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 016327 ACCOUNT ITEM LIST: Description 220.63 Account Code Current Pmts GAS - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.103.00.00 000.345.830 000.322.103.00.00 Total: $220.63 65.00 44.13 111.50 rinr. Rar.Pint-06 Printed: 07-16-2013 INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. ITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: RDST-20 n i Type of Innrection: , Na1,-splu,I-) Address: Ioc. C, r 1 6 1 1 Date Called: Special Instructions: Date Wanted: ' �' l- 13 "-\ p.m. Requester: Phone No: Q 63 `/ 3- 6C9 Approved per applicable codes. Corrections required prior to approval. tc COMMENTS: A\ !0-15"v1Af> f3T Iry 7 CTION FEE REQ RED. Prior (o next inspection. fee m. be 6300 Southcenter 8 vd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain .a copy with permit INSPECTI NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 • PG 13--10 2 Project: , . Type of Inspection: i t'1flL . NO 2t re.on" Address: 106 C Y LL Date Called: Special Instructions: Date Wanted: 4.. r1 Requester: Phone No: H -O( 73O_$7l/9 Approved per applicable codes. - D Corrections required prior to approval. CO ENTS: • Date:. REINSPECTION FEE QUIRE . Prior to next inspection. fee must be . paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. ' PERMIT NO. CITY QF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 `11/ 136,1 -?-,oZ Project: ►)0r.ai V)01 Type of Inspection: k?4 Rto1(4N-Iry ail, Address: 10 S�, rota1I Date Called: Cl- ( S Special Instructions: • Date Wanted: — 2O_ p.m. Requester: Phone No: o2o(. - 730- 57qC1 Approved per applicable codes. 1 ElCorrections required prior to approval. COMMENTS: Inspector Date 4_3 ..,9 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 FILE COPY C1 Stainless Steel Work Tables - "C6" Series - 4 Legs Part # - WKT####C6S Typical of unit supplied 45° f 6.00 2" x 6" Backsplash, 45° return, w/ 1/2" tum down for Mounting to Wall Clip (2 Each - 3" Wall Clips Included) 2.00 EVIEWED FOR E COMPLIANC APPROVED 'JUL 7 9 2013 City of Tukwila BUILDING DIVISION( 1.875 ('Cm*: Qty Model#: Length 0 Width 10.00 14 Gauge Heavy Duty Understructure 1 5/8"Stainless Steel Round Tube Legs with SS Adjustable Feet Gauge Type 304 Stainless Steel top with #4 Satin Finish 1 36.00 With 18 Gauge SS Undershelf Features: * Work table tops are constructed of 16 Gauge 304 Stainless Steel with #4 Satin Finish * Tables have a 14 gauge heavy duty understructure * With an 18 gauge stainless steel undershelf * 1 5/8" Stainless steel round tube legs with SS adjustable feet * Table working heights are 36" P&13 - Boz Options: Model Number U/M Adjustable Flange Feet Casters, (without brake) Casters, (with brake) 15" x 20" Drawer Assembly w/ Plastic Pan 15" x 20" Drawer Assembly w/ SS Pan 20" x 20" Drawer Assembly w/ Plastic Pan 20" x 20" Drawer Assembly w/ SS Pan Lower Table Height (State table work surface height) CHGA10-0854 CHGC23-1450 CHGC23-1451 SDA152006P SDA152006S SDA202006P SDA202006S LTH001 Orders Phone 888-618-2122 Fax 503-646-2348 www.pacificstainless.com RECEIVED each CITY OF TUKWILA each each each each each each Lot JUL 1 6 2013 PERMIT CENTER Pacific Stainless PRODUCTS, INC. Stainless Steel Work Tables "C6" Series - Table Lengths (15" to 138") Length 15" 18" 21" 24" 27" 30" 33" 36" 42" 48" 54" 60" 66" 72" Length 72" 78" 84" 90" 96" 102" 108" 114" 120" 126" 132" 138" Four Leg "C6" Series Tables with Undershelf 24" Wide Model WKT 1524C6S WKT1824C6S WKT2124C6S WKT2424C6S WKT2724C6S WKT3024C6S WKT3324C6S WKT3624C6S WKT4224C6S WKT4824C6S WKT 5424C6S WKT6024C6S WKT6624C6S WKT7224C6S 30" Wide Model WKT 1530 C6S WKT 183006S WKT 213006S WKT 243006S WKT 273006S WKT 303006S WKT 333006S WKT 363006S WKT 423006S WKT4830C6S WKT 543006S WKT 603006S WKT 663006S WKT 723006S 33" Wide Model WKT1533 C6S WKT1833 C6S WKT2133 C6S WKT2433 C6S WKT2733 C6S WKT3033 C6S WKT3333 C6S WKT3633 C6S WKT4233 C6S WKT4833 C6S WKT5433 C6S WKT6033 C6S WKT6633 C6S WKT7233C6S 36" Wide Model WKT1536C6S WKT1836C6S WKT2136C6S WKT2436C6S WKT2736C6S WKT3036C6S WKT3336C6S WKT3636C6S WKT4236C6S WKT4836C6S WKT5436C6S WKT6036C6S WKT6636C6S WKT7236C6S Six Leg "C6" Series Tables with Undershelf 24" Wide Model WKT 67224C6S WKT 7824C6S WKT 8424C6S WKT 9024C6S WKT 9624C6S WKT10224C6S WKT 10824C6S WKT 11424C6S WKT 12024C6S WKT 12624C6S WKT 13224C6S WKT 13824C6S 30" Wide Model WKT67230C6S WKT 783006S WKT 843006S WKT 903006S WKT 963006S WKT10230C6S WKT10830C6S WKT 1143006S WKT12030C6S WKT 12630 C6S WKT 13230 C6S WKT 13830 C6S 33" Wide Model WKT67233C6S WKT 7833C6S WKT 8433C6S WKT 9033C6S WKT 9633C6S WKT10233C6S WKT10833C6S WKT11433 C6S WKT12033C6S WKT12633C6S WKT13233C6S WKT13833C6S' "Custom Configurations Available" 36" Wide Model WKT67236C6S WKT 7836C6S WKT 8436C6S WKT 9036C6S WKT 9636C6S WKT10236C6S WKT10836C6S WKT 11436 C6S WKT12036C6S WKT12636C6S WKT13236C6S WKT 13836C6S Phone 888.618.2122 Fax 503.397.9596 E-mail info@pacificstainless.com r4 0111 (1+1 Stainless steel left hood enclosure panel, by PRD w BAKERS PRIDE HEARTHBAKE GP SERIES GAS COUNTER TOP OVENS SPECIFICATIONS Natural or LP gas heated counter top ovens. Standard specifications include two bake chambers each with 1" thick Cordierite ceramic hearth decks with independent bottom hinged doors, reversible side mounted handles, 40,000 to 60,000 BTUH per oven, 3/4" NPT (IS07) rear gas connection, and unique heat flow system that optimizes top and bottom heat. Bottom deck is best for rapid baking while the upper deck is for slower baking. Modulating thermostat saves energy and assures balanced heat. Standard thermostat has a temperature range up to 650° F (343°C) and is ideal for pizza while a no charge optional 550° F (287° C) thermostat is ideal for baking and roasting. A standard combination valve incorporates a manual gas valve, pilot safety and gas regulator. The oven exterior is constructed of durable stainless steel. Model GP -51 measures 32 5/8" wide (829mm) and model GP -61 measures 41 5/8" wide (1,057mm). Both models measure 31 1/4" deep (794mm) by 25 1/8" high (638mm) and may be double stacked. 4" (102mm) adjustable chrome plated legs are standard. The combustion chamber is constructed of 18 gauge type 304 stainless steel and features easily removable slide out flame diverter. The baking chamber is heavy gauge high heat aluminized steel. Interior bake chambers are 26 1/4" (667mm) deep and will each accommodate a full size sheet pan lengthwise. Bake chamber heights are 6" (152mm) on the lower deck and 5" (127mm) on the upper deck. Job Item # C3 GAS COUNTER TOP OVENS ❑ Model GP -51 Single Model GP -52 Dou ❑ Model GP -61 Single ❑ Model GP-61HP Single ❑ Model GP -62 Double ❑ Model GP -6214P Double STANDARD FEATURES 40,000 BTUH per oven model GP -51 and 45,000 BTUH per oven model GP -61 - 60,000 BTUH available on GP -61 HP Stackable for double production capacity Natural or propane gas Energy efficient ,modulating thermostat and combination gas control valve Unique heat flow system for optimum flexibility Standard 300° F (149°C) to 650° F (343°C) temperature range Two bake chambers per oven with 1" thick Cordierite ceramic hearth bake decks Two independent stainless steel, bottom hinged doors with field reversible handles for left or right hand operation 4" adjustable chrome plated legs All stainless steel exterior Stainless steel combustion chamber Aluminized steel bake chambers Slide -out flame diverter Front mounted, hinged control -valve access panel Heavy-duty industrial grade insulation in top, sides, back, bottom and doors OPTIONS & ACCESSORIES 60,000 BTUH on GP -61 / 12,000 BTUH on GP -62 Single door in lieu of double doors Removable upper deck on single door unit for 12" (308mm) bake and roast chamber height Bake and roast thermostat with 150 F (65 C) to 550 F (288 C) temperature range Automatic oven starter Draft hood for direct venting 16" (406mm) legs in stainless or Baker tone for stacked units 30" (762mm) legs in stainless or Baker tone for floor use Stainless steel under shelf for use with 30" (762mm) legs Heavy-duty caster set, two with locks, for use with 16" (406mm) or 30" (762mm) legs 48" (1219mm)quick-disconnect gas hose with or without restraining cable CERTIFICATIONS cp CDCE w BAKERS PRIDE BAKERS PRIDE OVEN COMPANY, INC. 30 Pine Street, New Rochelle, NY 10801 914/576-0200 • 1-800-431-2745 • fax 914/576-0605 www.bakerspride.com Continuous product improvement is a policy of Bakers Pride Oven Company. Therefore, specifications and design are subject to change without notification 20" (508 mm) 25 1/8' (638 mm) r� =:1 w (overall dimension) FRONT VIEW FLUE VENT 6' (152 mm) DIAMETER 2 1/4" j" (57 mm) 49 1/8" (1248 mm) GP -51 14 7/8" (378mm) GP -61 19 3/8' (492 mm) 3" (76 mm) SHIPPING INFORMATION TOP VIEW 41 /16' (103 mm) 5 3/8° (137 mm) 7 1/4" (184 mm) 34 7/8" (886 mm) 7 1/4" (184 mm) 9 3/4' (248 mm) 4 " (102 mm) 31 1/4" (794 mm) 1/2" (13 mm) 48 /4' (1226 mm) -1 23 1/8" (587 mm) i 54 /4" (1378 mm) LL 26 1/8" (664 mm) 28 3/4' (730 mm) STACKED UNIT SIDE VIEW Shipping Weight Canon Dimensions 11. Bilos Width Be b He'ght lochs mm lodes mm laches mm GP -51 GP -52 GP -61 GP -62 Shipping pass # 70 I 1 shipped Crate Size Cebic Cubic Feet Meter 43.8 1.2 525 483 52 1321 39 991 36 915 43.8 1.2 shipped in two GP -61 cartons SPECIFICATIONS Model Deck Size io. mm MUST BE SPECIFIED AT TIME OF ORDER # of # Cooking Overall Dimensions" Decks Chambers Widlh Depth Hei ht• loches mm fiches mm locks mm GP -51 20 5/8x26 1/4 524x667 2 2 32 5/8 829 31 1/4 794 29 1/8 740 GP -52 20 5/8x26 1/4 524x667 4 4 32 5/8 829 31 1/4 794 54 1/4 GP -61 29 5/8x26 1/4 752x667 2 2 41 5/8 1057 31 1/4 794 29 1/8 GP -62 29 5/8x26 1/4 752x667 4 4 41 5/8 1057 31 1/4 794 54 1/4 1378 740 1378 NOtE 6761 / 62 HP same d menslons as standard 07-61 / 62 *Height include: 4' (102 mm) standard legs 2 1/2" (64 mm) 12" (305mm) 1 6" (152 mm) For Installation Under Ventilation Hood STANDARD GAS SUPPLY — 3/4" NPT gos connection Model BTUH KW GP -51 40,000 11.72 GP -52 80,000 23.44 GP -61 45,000 13.19 GP -62 90,000 26.37 GP -61 HP 60,000 17.58 GP-62HP 120,000 CE certification n t available in LP gas Each oven requires separate gas connection 35.16 MINIMUM CLEARANCES Lemke:tihle Nen.Comhostihle Ceastrsctios Ceastrmioa lnches mm fiches mm Right 2 51 2 51 Left 1 25 0 0 Rear 5 127 2 51 • From non combustable constructio .27 BAKERS PRIDE BAKERS PRIDE OVEN COMPANY, INC. 30 Pine Street, New Rochelle, NY 10801 914/576-0200 • 1-800-431-2745 • fax 914/576-0605 www.bakerspride.com Continuous product improvement is a policy of Bakers Pride Oven Company. Therefore, specifications and design are subject to change without notification TS: 03/04 Gas Appliance Connectors Safe -T -Link SwiveLink (optional, gas only) Specify the new SwlveLlnk swivel, the ultimate connector accessory, and you gain increased mobility and critical space savings over fixed -end products. For the first time, let SwiveLink connect you to the ultimate convenience of utilizing 100% of the connector's overall length. Safe -T -Link FreeSpin (standard, gas only) With the new FreeSpin feature, you hook up with the most technically advanced end fitting available in the industry. These "live ends — standard on both ends of the T&S Safe -T -Link gas connectors - provide a constant 360° rotation for reducing stress while extending connector life. Plus, the entire fitting design helps increase operational safety. Quick -Disconnect Advantages • For use when you need a Quick - disconnect located at the back of the appliance', • Quick -disconnect socket acts as shut-off valve when the plug and socket are disconnected • High quality construction • CSA approval • Easy operation Reversed Quick - Disconnect Advantages • For use when you need a Quick - disconnect located at the wall • Quick -disconnect socket acts as shut-off valve when the plug and socket are disconnected • High quality construction • CSA approval • Easy operation C3a The Safe T Link Advantage Welded Fittings A gas connector is only as good as its weakest link. Trust our welded fittings to remain gas-tight long after a competitor's crimped assembly begins to loosen. Extruded Coating Strong does not have to mean Tess flexible. Our extruded coating stays out of the braid and keeps a constant wall thickness, providing strength and flexibility. Dipped coat- ings invade the stainless steel braid and stress the wires while reducing flexiblity. Safest Stainless Braid Stainless braids protect the thin inner hose from presure and stress. Trust our tight braid pattern to prevent punctures or dents more than a gapped braid. SAFETLINK Hot and cold water appliance connectors are also available S;AFE•TLINK Gas Appliance Connectors HG -2 Series with FreeSpin Fittings • FreeSpin rotating gas fittings on both ends, male to male • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure • Welded fittings • Extruded coating HG -4 Series with Quick -Disconnect End • Quick -disconnect one end, FreeSpin rotating gas fitting other end • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure HG -6 Series Isievemeai Quick -Disconnect • Male to quick -disconnect plug (reversed quick - disconnect) one / end, FreeSpin l rotating gas fitting C other end • Welded fittings • Extruded coating • Stainless steel braid hose • 1/2 PSI max. gas pressure Gas Hose Fittings FreeSpin Fittings • Standard on both gas hose ends • Freely rotates 360° even when tight, ending twisted hoses • Tapered fittings for tighter fit • Hose does not have to turn to tighten fittings • Available in sizes 1/2" through 1-1/4" • 1/2 PSI max. gas pressure • Stainless braid HG -2-S Series with SwiveLinit Nettings Add an "S" to include SwiveLink swivels at both ends • Maximum clearance from wall • Minimum folded length • Stress -free and torque -free motion • No Tock -up position • 1/2 PSI max. gas pressure HG -4-S Series with Quick -Disconnect and SwiveLink Ends Add an "S" to include SwiveLink swivels at both ends • Maximum clearance from wall • Minimum folded length • Stress -free and ' torque -free motion • No lock-up position • 1/2 PSI max. gas pressure HG -S Series Stationary Appliance Gas Connectors • Stainless steel stationary appliance gas connector • Available in 3/4" thread • 36" to 48" length • 1/2 PSI max. gas pressure SwiveLink Fittings • Provides the most reach with the shortest hose • Reduces stress on the hose, eliminating kinking • Keeps gas flow unrestricted • Patented design; can't lock up • Meets ANSI Z21.69 for B.T.U. capacity • Available in sizes 1/2" through 1-1/4" • 1/2 PSI max. gas pressure (,'-s-VotUats Gas Appliance Connectors Gas Appliance Connectors - Specifications S/FETLINK Specifying An HG -2 and HG -4 Gas Appliance Connector Hose Design HG - 4 Order Male to Male Male to Quick -Disconnect Internal Thread and Diameter Order 3/z' 3/4`" N.P.T. D 1" N.P.T. E 11/4" N.P.T. F Example: Gas hose and Installation Kit with Quick -Disconnect, 3/4" N.P.T. and 48" long with Swivelink fittings: HG 4D 48SK` D _ 48 SK Length Order 24" 24 36" 36 4$" 48 60" 60 72" 72 Suffixes Order SwiveLlnk Add SwiveLink.fitting to both ends of the hose assembly S* Installation Kit Includes everything necessary for an installation K* POST -SETT" Includes one pair POSI-SET (Wheel• Placement System for Moveable Cooking Equip.) PS** * You may add an "S" and/or "K" suffix to your order ** Models -2C, -2D, -4C, -4D and -4E only Specifying An FIG -6 Gas Appliance Connector Example: Gas hose with Reverse Qu ck-Disconnect, 3/4" N.P.T., 48" long: HG -6 Thread and Diameter Yz" N.P.T. C 3/4" N.P.T. D 1" N.P.T. E 11" N.P.T. F HG 6D - 48 Hose Length Order 24" 36" 48" 60" 72" 24 36 48 60;, 72 HG -2 HG -2S HG -4 HG -4S Specifying A Stationary Appliance Connector HG -8 Thread and Diameter Example: Stationary gas hose, 3/4" diameter, 48" long: HG -SD -48 Hose Length Order 36" 36 48" 48 HG -6 HG -S . Gas Appliance Installation Kit Gas Hose with Installation Kit Add a "K" suffix to hose model number (see p. F7) to include all necessary pieces to install a gas appliance. Each kit includes: • One 90° street elbow • One CSA -certified foodservice gas ball valve • One SureLink restraining cable, adjustable from 3' to 5' lengths (#010625-45) • All necessary hardware Gas Appliance Parts, Components and Accessories Quick -Disconnect Gas Ball Valve POSI-SETTm I Placement System • Wheel placement system for moveable cooking equipment • Designed for the positive placement of moveable gas equipment • Ensures proper relocation of equipment after moving, cleaning or repairs • Made of flame retardant thermoplastic resin • Virtually indestructible • Includes mounting hardware for proper installation • Designed to meet the requirements of NFPA 17A 5.6.4 2009 Edition • Patent No. US 7,581,623 SwiveLink N EW POSI-SET" Models! K Model Installation Kit Order with these model numbers when you only want the kit: Elbows* • All Elbows are in compliance with ASTM standards * Use of Street Els not recommended in Canada Existing six burner range, by Owner • JGEND Heavy -Duty Gas Underfired Broilers - Radiant Style Range Match Cabinet Base Item No. C5 Project Quantity Model UF -24R shown, with optional lower warming rack SHORT/BID SPECIFICATION Broiler shall be a Montague Legend Heavy -Duty Range -Match Cabinet Base Model: ❑ UF- _ R [Specify width]: ...a gas-fired unit with 19,000 BTU/hr stainless steel tubular burners with individual controls, heating heavy-duty stainless steel radiant heat deflectors (radiants), with a full width debris screen under burners; two -position, reversible cast-iron ULTRA -FLOW top grates with both flat (wide) and ribbed sides (narrow with grease troughs); a full width front grease trough and large capacity grease container located in cool zone; 6" (152 mm) front/plate rail, 5-9/16" (141 mm) high side and rear grease splash mounted on a stainless steel cabinet base with 6" (152 mm) legs as standard; plus all the features listed and options/accessories checked: BURNER/RADIANT SYSTEM FEATURES: • 19,000 BTU/hr stainless steel tubular burners • Individual manual gas valves for zoned heat control • Standing pilot for automatic ignition • Heavy-duty stainless steel radiants glow red for infrared broiling • Removable self-cleaning radiants • Full width debris screen under burners • Full width removable drip tray • Radiants and drip tray heat shields to reduce flare-ups UF -R Series MODEL GUIDE OF -24R 24" (610 mm) 3 18" x 24" (457 x 610 mm) s" .2 mm 4 0. " • . + m OF -36R 36" (914 mm) 5 30" x 24" (762 x 610 mm) UF -48R 48" (1219 mm) 6 36" x 24" (914 x 610 mm) UF -60R 60" (1524 mm) 8 48" x 24" (1219 x 610 mm) UF -72R 72" (1829 mm) 10 60" x 24" (1524 x 610 mm) TOP -GRATE FEATURES: • Reversible ULTRA -FLOW cast-iron grate sections • Ribbed side for narrow marking, with side grease troughs • Flat side for broiling fish and wide marking • 1" (25 mm) ribbed grate spacing for consistent grilling results • Three -position grid frame for adjustment from flat to 3" (76 mm) raised -rear • Sloped grates and side grate grease troughs to reduce flare-ups STANDARD CONSTRUCTION FEATURES: • Satin finish stainless steel front & top trim with 6" (152 mm) deep front rail • 5-9/16" (141 mm) high stainless steel side and rear splash • Enclosed cabinet base with 6" (152 mm) adjustable stainless steel legs • Other surfaces painted black with electrolytic zinc undercoating • Full width front grease trough for easy transfer • Removable large capacity grease container • 1-1/4" NPT front gas manifold with V2 union on each end STANDARD WARRANTY • One Year, Parts & Labor AGENCY APPROVALS • NSF Listed • CSA Design Certified to ANSI Z83.11*CSA 1.8 HDB-3 [Rev. 09/09] THE MONTAGUE COMPANY • 1830 Stearman Avenue, Hayward, CA 94545 • 800 345-1830 • Fax: 510 785-3342 • montaguecompany.com 1. '0 JGEND Heavy -Duty Gas Underfired Broilers — Radiant Stele Range Match Cabinet Base Item No. Project Quantity UF -R Series 353/5 [899] 1. 6 [152] ADJ. J J. FRONT VIEW OPTIONAL REAR GAS SUPPLY 30 [762] I1 [857] RIGHT SIDE VIEW 7-9CAQ [505] Dimensions in brackets are millimeters OPTIONAL REAR GAS SUPPLY [ q+7F 37y4 [946] 1 6 [152] MODEL WIDTH TOP VIEW OPTIONS GUIDE: General: ❑ 42" (1067 mm) unit depth (Suffix -40) [Same grid size] ❑ Casters — set of four/six 5" (127 mm) casters ❑ Flex Connector Kit (1"] NPT: ❑ 3' (914 mm) long 0 4' (1219 mm) long 0 13" (330 mm) High Back [Matches 18" (457 mm) range back]: 0 stainless steel 0 black ❑ Curb Mounting ❑ Lower Warming Rack 0 Removable splash guard, stainless steel Manifolds: [Left rear, with pressure regulator]: ❑1"NPT Manifold Cap: 0 left side 0 right side Stainless Manifold Coven 0 left side 0 right side Grates, Radiants, Plate Shelves 0 Seafood grates, cast iron 0 Round rod grates — 6" (152 mm) sections: 0 Hard chrome 0 Cold rolled steel 0 Scraper/cleaner for round rod grates 0 Cast iron radiants — in place of stainless steel 0 Wider Plate Shelli 0 9" (229 mm) ❑ 11" (279 mm) 0 Plate Shelf Cutouts [for 11" (279 mm) only]: Fin 0 0 0 0 Specify: 01/6 pans or 0 1/4 pans or 0 1/9 pans number. _ ea. Ish/Cabinet Upgrades: Stainless steel left side panel Stainless steel right side panel Stainless steel back panel Stainless steel bottom cabinet shelf Stainless steel cabinet base doors INSTALLATION REQUIREMENTS & SHIPPING INFORMATION 1. Broilers must be installed in accordance with local codes or in their absence with the National Fuel Gas Code: ANSI Z223.1; Natural Fuel Gas Code: CAN/CGA-B149.1 or Propane Installation Code: CAN/CGA-B149.2, as applicable. Compliance with codes is the responsibility of the Owner and Installer. 2. An adequate ventilation system is required. Refer to National Fire Protection Association Standard No. 96, "Standard for Ventilation and Fire Protection of Commercial Cooking Operations." 3. This appliance is intended for commercial use by professionally trained personneL NOT intended for Residential Use. 4. Specify installation elevation: if above 2000 feet (610 m). 5. GAS INLET SIZE (AU Models): 1-1/4" NPT front manifold with 1/2 union on each end provided for battery con- nection. A properly sized gas pressure regulator must be furnished by the Installer. With 1" rear inlets, a gas pressure regulator is provided and must be installed (by others) when unit is connected to gas supply. Minimum Clearances Noncombustible Construction From Back Wall 0" Left & Right Side 0" For use in noncombustible locations only. Specify Type of Gas: 0 Natural 0 Propane Shiyyirni a•,� Cube Crated) " 496 WC Models: Burners BTU/hr (kW) BTU/hr (kW) Weight Class UF -24R 4 80,000 (23.4) 80,000 (23.4) 372 Lbs (169 kg) 85 21/.6 ` ` IMOR--- 100 000 (29 3) 100 000 (29 3) 402 Ibs,.(182 ) 84--------'-"'32)9 UF -36R 6 120,000 (35.2) 120,000 (35.2) 432 tbs (196 kg) 85 32/.9 UF -48R 8 160,000 (46.9) 160,000 (46.9) 744 lbs (337 kg) 85 46/1.3 UF -60R 10 200,000 (58.6) 200,000 (58.6) 804 lbs (364 kg) 85 65/1.8 UF -72R 12 240,000 (70.3) 240,000 (70.3) 864 tbs (391 kg) 85 65/1.8 Due to continuous product improvements, specifications are subject to change without notice. THE MONTAGUE COMPANY 1830 Stearman Avenue, Hayward, CA 94545 800 345-1830 • Fax: 510 785-3342 www.montaguecompany.com HDB-3 [Rev. 09/09] Gas Appliance Connectors Safe -T -Link SwiveLink (optional, gas only) Specify the new SwiveLink swivel, the ultimate connector accessory, and you gain increased mobility and critical space savings over fixed -end products. For the first time, let SwiveLink connect you to the ultimate convenience of utilizing 100% of the connector's overall length. Safe T Link FreeSpin (standard, gas only) With the new FreeSpin feature, you hook up with the most technically advanced end fitting available in the industry. These "live" ends — standard on both ends of the T&S Safe -T -Link gas connectors — provide a constant 360° rotation for reducing stress while extending connector life. Plus, the entire fitting design helps increase operational safety. Quick -Disconnect Advantages • For use when you need a Quick - disconnect located at the back of the appliance • Quick -disconnect socket acts as shut-off valve when the plug and socket are disconnected • High quality construction • CSA approval • Easy operation Reversed Quick - Disconnect Advantages • For use when you need a Quick - disconnect located at the wall • Quick -disconnect socket acts as shut-off valve when the plug and socket are disconnected • High quality construction • CSA approval • Easy operation C5a The Safe -T -Link Advantage Welded Fittings. A gas connector is only as good as its weakest link. Trust our welded fittings to remain gas-tight long after a competitor's crimped assembly begins to loosen. Extruded Coating Strong does not have to mean less flexible. Our extruded coating stays out of the braid and keeps a constant wall thickness, providing strength and flexibility. Dipped coat- ings invade the stainless steel braid and stress the wires while reducing flexiblity. Safest Stainless Braid Stainless braids protect the thin inner hose from presure and stress. Trust our tight braid pattern to prevent punctures or dents more than a gapped braid. rSgFEmLINK Hot and cold water appliance connectors are also available SAFETtINK Gas Appliance Connectors HG -2 Series van [FveeSpnfin [Fittfings • FreeSpin rotating gas fittings on both ends, male to male • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure • Welded fittings • Extruded coating • Stainless braid HG -4 Series Mik[ln Qaafich-®fisconnect End • Quick -disconnect one end, FreeSpin rotating gas fitting other end • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure HG -6 Series Meerersed Q,auBcck-®fisconnect • Male to quick -disconnect plug (reversed quick - disconnect) one end, FreeSpin rotating gas fitting \,, other end • Welded fittings \\„, • Extruded coating • • Stainless steel braid hose • 1/2 PSI max. gas pressure Gas Hose Fittings FreeSpin Fittings • Standard on both gas hose ends • Freely rotates 360° even when tight, ending twisted hoses • Tapered fittings for tighter fit • Hose does not have to turn to tighten fittings • Available in sizes 1/2" through 1-1/4" • 1/2 P51 max. gas pressure HG -2-S Series ebfit(fn SwfiereLonk (Fittings Add an "S" to include SwiveLink swivels at both ends • Maximum clearance from wall • Minimum folded ((� length • Stress -free and torque -free motion • No lock-up position • 1/2 PSI max. gas pressure HG -4-S Series MTh Qanfick-Misconnect and SebfiereRkik Ends Add an "S" to include SwiveLink swivels at both ends • Maximum clearance --- from wall i • Minimum folded length • Stress -free and torque -free motion • No lock-up position • 1/2 PSI max. gas pressure HG -S Series Stationary Apnp lifiancce (has Connectors • Stainless steel stationary appliance gas connector • Available in 3/4" thread • 36" to 48" length • 1/2 PSI max. gas pressure SwiveLink Fittings • Provides the most reach with the shortest hose • Reduces stress on the hose, eliminating kinking • Keeps gas flow unrestricted • Patented design; can't lock up • Meets ANSI Z21.69 for B.T.U. capacity • Available in sizes 1/2" through 1-1/4" • 1/2 PSI max. gas pressure • ,4 Gas Appliance Connectors Gas Appliance Connectors - Specifications S1FETLINK Specifying An HG -2 and HG -4 Gas Appliance Connector Hose Design HG - 4 Order Male to Male 2 Male to Quick -Disconnect 4 Internal Thread and Diameter Order Y2" N.P.T. 3/4" N.P.T. 1" N.P.T. 11/4" N.P.T. c D E F Example: Gas hose and Installation Kit with Quick -Disconnect, 3/4" N.P.T. and 48" long with SwiveLink fittings: HG - 4D - 48SK E _ 48 SK Length Order 24" 36" 48" 60" 72" 24 36 48 60 72 Suffixes Order SwiveLink Add SwiveLink fitting to both ends of the hose assembly S* Installation Kit Includes everything necessary for an installation K* POSI-SETTM' Includes one pair POST -SET (Wheel Placement System for Moveable Cooking Equip.) PS** " You may add an "S" and/or "K" suffix to your order "" Models -2C, -2D, -4C, -4D and -4E only Specifying An HG -6 Gas Appliance Connector Example: Gas hose with Reverse Qu ck-Disconnect, 3/4" N.P.T., 48" long: HG -6 Thread and Diameter Hose Length 1/2" N.P.T. 3/4" N.P.T. 1" N.P.T. 11/4" N.P.T. c D E F HG 6D 48 Order 24" 36" 48" 60" 72" 24 36 48 60 72 HG -2 HG -2S HG -4 HG -4S Specifying A Stationary Appliance Connector HGS Thread and Diameter Example: Stationary gas hose, 3/4" diameter, 48" long: HG -SD -48 Hose Length Order 36" 48" 36 48 HG -6 HG -S Gas Appliance Installation Kit Gas Hose with Installation Kit Add a "K" suffix to hose model number (see p. F7) to include all necessary pieces to install a gas appliance. Each kit includes: • One 90° street elbow • One CSA -certified foodservice gas ball valve • One SureLink restraining cable, adjustable from 3' to 5' lengths (#010625-45) • All necessary hardware Gas Appliance Parts, Components and Accessories Quick -Disconnect Gas Ball Valve POSI-SETTm Wheel Placement System • Wheel placement system for moveable cooking equipment • Designed for the positive placement of moveable gas equipment • Ensures proper relocation of equipment after moving, cleaning or repairs • Made of flame retardant thermoplastic resin • Virtually indestructible • Includes mounting hardware for proper installation • Designed to meet the requirements of NFPA 17A 5.6.4 2009 Edition • Patent No. US 7,581,623 SwiveLink NEW POSI-SET' Models! K Model Installation Kit Order with these model numbers when you only want the kit: Elbows* • All Elbows are in compliance with ASTM standards * Use of Street Els not recommended in Canada C6 Existing exhaust hood, by Owner C7 Existing worktable, by Owner C8 New exhaust hood, by PSF C9 Relocated kettle and stand, by Owner ocvs T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com Model No. B-0597 Item No. C10 This Space for Architect/Engineer Approval • Job Name Model Specified Customer/Wholesaler Contractor Date Quantity Architect/Engineer Eterna Cartridges w/ Spring Checks & Lever Handles w/ Color Coded Indexes Swivel Joint 18" [456mm] L 12" [ 304mm ] Swivel Joint 3 1/2" [91m] 2 1/8" [ 54mm ] . 8" [ 203mm ] Adjustable From 7 3/4" to 8 1/4" [197mm to 210mm] Heat Resistant "On -Off' Handle 2 3/8" [61mm] 02"[51mm] Flanges w/ 1/2" NPT Female Inlets Mounting Surface Product Specifications: 8" Center Pot Filler Mixing Faucet w/ 18" Double Joint Swing Nozzle, Heat Resistant Handle, Eterna Cartridges w/ Spring Checks Lever Handles & 1/2" NPT Female Inlets Drawn DHL Checked DMH Approved JHB Scale: 1:5 Date: 01/05/12 Sheet: 1 of 2 13) T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com Model No. B-0597 Item No. ITEM SALES NO. NO. DESCRIPTION 1 000936-45 2 000587-25 3 001498-25 4 001089-45 5 003426-45 6 002848-40 7 002870-40 8 009538-45 9 001074-45 10 011429-45 11 002871-40 12 001660-45 13 002711-40 14 00AA 15 001019-45 16 002712-40 17 001638-45 18 001661-45 19 001126-20 20 035A 21 000922-45 Product Specifications: 8" Center Pot Filler Mixing Faucet w/ 18" Double Joint Swing Nozzle, Heat Resistant Handle, Eterna Cartridges w/ Spring Checks Lever Handles & 1/2" NPT Female Inlets Drawn Handle Set Screw Spout Body Spout Seal 0 -Ring Double Jt Nozzle Asm 18" 6" Front Section Asm Swivel Washer 0 -Ring Swivel Sleeves (2) 12" Back Section Asm Blue Index -CW Eterna Cartridge, LTC w/ Spring Check, Handle, Index & Screw Coupling Flange Asm Coupling Nut Washer Eterna Cartridge, RTC w/ Spring. Check, Handle, Index & Screw Lever Handle Red Index -HW Handle w/ (2) Set Screws Outlet Asm Lever Handle Screw DHL Checked DMH Approved JHB Scale: NTS Date: 01/05/12 ISheet: 2 of 2 [BLODGETT MODEL ZEPHAIRE-G PLUS Full -Size Gas Convection Oven Shown with optional casters OPTIONS AND ACCESSORIES (AT ADDITIONAL CHARGE) • Legslcasterslstands: ❑ 6" (152mm) seismic legs ❑ 6" (152mm) casters ❑ 4" (107mm) low profile casters ❑ 25" (635mm) stainless steel open stand with rack guides • Gas hose with quick disconnect and restraining device: ❑ 48" (1219mm) hose ❑ 36° (914mm) hose ❑ Solid state digital control with LED display, Cook & Hold and Pulse Plus ❑ Extra oven racks ❑ Gas manifold (for double sections) ❑ Stainless steel solid back panel ❑ Extended warranty OPTIONS AND ACCESSORIES (AT NO ADDITIONAL CHARGE) ❑ Solid stainless steel doors Project Item No. Quantity Extra depth baking compartment - accepts five 18" x 26" standard full-size baking pans in left-to-right or front -to -back positions. All data is shown per oven section, unless otherwise indicated. Refer to operator manual specification chart for listed model name. EXTERIOR CONSTRUCTION • Full angle iron frame • Stainless steel front, top, sides and legs • Dual pane thermal glass windows encased in stainless steel door frames • Porcelain door handle with simultaneous door operation • Triple -mounted pressure lock door design with tumbuckle assembly • Removable front control panel • Solid mineral fiber insulation at top, back, sides and bottom INTERIOR CONSTRUCTION • Double -sided porcelainized baking compartment liner (14 gauge) • Aluminized steel combustion chamber • Dual inlet blower wheel • Five chrome -plated racks, eleven rack positions with a minimum of 1-5/8" (41mm) spacing OPERATION • Dual Flow Gas system combines direct and indirect heat ■ Electronic spark ignition control system • Removable dual tube burners • Pressure regulator and manual gas service cut-off valve located in front control area • Air mixers with adjustable air shutters • Solid state thermostat with temperature control range of 200°F (93°C) to 500°F (260°C) ■ Two speed fan motor • 1/3 horsepower blower motor with automatic thermal overload protection • Control area cooling fan • Two 50 watt commercial bake oven lamps STANDARD FEATURES • Solid state manual controls with separate dials for thermostat and timer • 25" (635mm) adjustable stainless steel legs (for single units) • 6" (152mm) adjustable stainless steel legs (for double sections) • Draft diverter or draft hood for venting (select one) • 60 minute electric timer with buzzer • Porcelainized oven liner • One year parts and labor oven warranty* ■ Three year limited oven door warranty* • For all international markets, contact your local distributor. Intertek CE BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183 ENERGY STAR N rn m -a r c co C11 BLODGETT MODEL ZEPHAIRE-G PLUS 6° dia. (152mm) SINGLE OVEN 8" dia. (203mm) DOUBLE OVEN 7-3/8" (187) 17" (432) -1 3" (76) 36-7/8" (937) 1(441)• I_ 38-114° (972) TOP VIEW Dimensions are in inches (mm) 2" (51) 4_ 3° (76) DRAFT DIVERTER 57"(1448 51-3/4" (1315 SINGLE APPROVAUSTAMP DRAFTHOOD Single add 12-3/4' (324) Double add 16-1/2" (419) 70-5/8"(1794) 16-1/4" (413) 38-9/16" (979) 33-1/4" (845) 17" (432) 6-1/2" (165)- 0- DOUBLE 42"(1067) 10" (254) 7-5/8" (194) SHORT FORM SPECIFICATIONS Provide Blodgett full-size convection oven model ZEPHAIRE PLUS, (single/double) compartment. Each compartment shall have porcelainized steel liner and shall accept five 18' x 26' standard full-size bake pans in left-to-right or front -to -back positions. Doors shall have dual pane thermal glass windows with single porcelain handle and simultaneous operation. Unit shall be gas heated with electronic spark ignition and shall cook by means of a dual -flow system combining direct and indirect heat. Air in baking chamber distributed by dual inlet blower wheel powered by a two speed, 1/3 HP motor with thermal Overload protection. Each chamber shall be fitted with five chrome -plated removable racks. Control panel shall be recessed with Cook/Cool Down mode selector, solid state manual infinite thermostat (200 - 500°F), and 60 -minute timer. Provide options and accessories as indicated. DIMENSIONS: Floor space 38-1/4" (972mm) W x 36-7/8" (936mm) L Product clearance 6° from combustible and non-combustible construction. Interior 29" (737mm) W x 20" (508mm) H x 28-1/4" (718mm) D If oven is on casters: Single Add 4-1/2" (114mm) to all height dimensions Double Dimensions do not change Double Low Profile Subtract 2-1/2" (64mm) from all dimensions GAS SUPPLY: connection at rear o ove 1 -'•`CI •. ani o • Natural — 3.5" W.0 Inlet Pressure: • Natural — 7.0" W.C. min. — 10.5" W.C. max. • Propane — 10.5" W.C. min. — 13.0" W.C. max. • Propane — 10" W.C. MAXIMUM INPUT: Sin Double 120,000 BTU/hr (60,000 each section POWER SUPPLY: 115 VAC, 1 phase, 6 Amp, 60 Hz., 2 -wire with ground, 1/3 H.P., 2 speed motor, 1140 and 1725 RPM 230, 220/240VAC, 1 phase, 3 Amp, 50 Hz., 2 -wire with ground, 1/3 H.P., 1 speed motor, 1425 RPM 6' (1.8m) electric cord set fumished on 115 VAC ovens only. MINIMUM ENTRY CLEARANCE: Uncrated 32-1/16" (814mm) Crated 37-1/2" (953mm) SHIPPING INFORMATION: Approx. Weight: Single: 617 lbs. (280 kg) Double: 1193 lbs. (541 kg) Crate sizes: 37-1/2" (952mm) x 43-1/2" (1105mm) x 51-3/4° (1315mm) NOTE: The company reserves the right to make substitutions of components without prior notice Printed in U.S.A. BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183 NOTE: FOR COMMERCIAL USE ONLY P1N36101 Rev N (5/11) Gas Appliance Connectors Safe -T -Link SwiveLink (optional, gas only) Specifythe new SwiveLink swivel, the ultimate connector accessory, and you gain increased mobility and critical space savings over fixed -end products. For the first time, let SwiveLink connect you to the ultimate convenience of utilizing 100% of the connector's overall length. Safe -T -Link FreeSpin (standard, gas only) With the new FreeSpin feature, you hook up with the most technically advanced end fitting available in the industry. These "live" ends — standard on both ends of the T&S Safe -T -Link gas connectors — provide a constant 360° rotation for reducing stress while extending connector life. Plus, the entire fitting design helps increase operational safety. Quick -Disconnect Advantages • For use when you need a Quick - disconnect located at the back of the appliance • Quick -disconnect socket acts as shut-off valve when, the plug and socket are disconnected • High quality construction • CSA approval • Easy operation Reversed Quick - Disconnect Advantages • For use when you need a Quick - disconnect located at the wall • Quick -disconnect socket acts as shut-off valve when the plug and socket are disconnected • High quality construction • CSA approval • Easy operation C11a The Safe T Link Advantage Welded Fittings A gas connector is only as good as its weakest link. Trust our welded fittings to remain gas-tight long after a competitor's crimped assembly begins to loosen. Extruded Coating Strong does not have to mean less flexible. Our extruded coating stays out of the braid and keeps a constant wall thickness, providing strength and flexibility. Dipped coat- ings invade the stainless steel braid and stress the wires while reducing flexiblity. Safest Stainless Braid Stainless braids protect the thin inner hose from presure and stress. Trust our tight braid pattern to prevent punctures or dents more than a gapped braid. SAFETLINK Hot and cold water appliance connectors are also available •TLIN}( Gas Appliance Connectors • Welded fittings • Extruded coating • Stainless braid HG -2 Series w tTo f reeSpOn IFiittings • FreeSpin rotating gas fittings on both ends, male to male • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure HG -4 Series with Qaoich-Dliscconnect End • Quick -disconnect one end, FreeSpin rotating gas fitting other end • Welded fitting connections • Safe stainless braid • Extruded coating • 1/2 PSI max. gas pressure HG -6 Series Reversed Qanich-DD iscconnect • Male to quick -disconnect plug (reversed quick - disconnect) one end, FreeSpin rotating gas fitting other end • Welded fittings • Extruded coating • Stainless steel braid hose • 1/2 PSI max. gas pressure Gas Hose Fittings FreeSpin Fittings • Standard on both gas hose ends • Freely rotates 360° even when tight, ending twisted hoses • Tapered fittings for tighter fit • Hose does not have to turn to tighten fittings • Available in sizes 1/2" through 1-1/4" • 1/2 PSI max. gas pressure HG -2-S Series snit SwiveEitrgh Vittiangs Add an "S" to include SwiveLink swivels at both ends • Maximum clearance from wall • Minimum folded length • Stress -free and torque -free motion • No lock-up position • 1/2 PSI max. gas pressure HG -4-S Series vinila Qaeick=Dilscoovnoecct and SwiveLink Ends Add an "5" to include Swivelink swivels at both ends • Maximum clearance from wall / • Minimum folded length • Stress -free and torque -free motion • No lock-up position • 1/2 PSI max. gas pressure HG -S Series Stationary Apppiaunee Gass Connectors • Stainless steel stationary appliance gas connector • Available in 3/4" thread • 36" to 48" length • 1/2 PSI max. gas pressure SwiveLink Fittings • Provides the most reach with the shortest hose • Reduces stress on the hose, eliminating kinking • Keeps gas flow unrestricted • Patented design; can't lock up • Meets ANSI Z21.69 for B.T.U. capacity • Available in sizes 1/2" through 1-1/4" • 1/2 PSI max. gas pressure i`r.03-11iis Gas Appliance Connectors Gas Appliance Connectors - Specifications SAFE:I:LINK Specifying An HG -2 and HG -4 Gas Appliance Connector Hose Design E Male to Male 2 Male to Quick -Disconnect 4 Internal Thread and Diameter Order i/z" N, P.T. 3/4' N.P.T. 1" N.P.T. 11/4" N.P.T. C D E F Example: Gas hose and Installation Kit with Quick -Disconnect, 3/4" N.P.T. and 48" long with SwiveLink fittings: HG - 4D - 48SK 36 SK Suffixes • Length Order 24" 36" 48" 60" 72" 24 36 48 60 72 Order SwiveLink Add SwiveLink fitting to both ends of the hose assembly S* Installation Kit Includes everything necessary for an installation K* POSI-SETT"' Includes one pair POSI-SET (Wheel Placement System for Moveable Cooking Equip.) PS** * You may add an "S" and/or "K" suffix to your order ** Models -2C, -2D, -4C, -4D and -4E only Specifying An HG -6 Gas Appliance Connector Example: Gas hose with Reverse Quick -Disconnect, 3/4" N.P.T., 48" long: HG -6 Thread and Diameter Hose Length 1/2" N.P.T. N.P.T. 1" N.P.T. 1W N.P.T. C D E F HG - 6D 48 Order 24" 36" 48" 60" 72" 24 36 48 60 72 HG -2 HG -2S HG -4 HG -4S Specifying A Stationary Appliance Connector HG -S Thread and Diameter 3/4 D Example: Stationary gas hose, 3/4" diameter, 48" long: HG SD - 48 Hose Length Order 36" 48 36 48 HG -6 Q* HG -S Gas Appliance Installation Kit Gas Hose with Installation Kit Add a "K" suffix to hose model number (see p. F7) to include all necessary pieces to install a gas appliance. Each kit includes: • One 90° street elbow • One CSA -certified foodservice gas ball valve • One SureLink restraining cable, adjustable from 3' to 5' lengths (#010625-45) • All necessary hardware Gas Appliance Parts, Components and Accessories Quick -Disconnect Gas Ball Valve SwiveLink POSI-SETTM Wheel Placement System • Wheel placement system for moveable cooking equipment • Designed for the positive placement of moveable gas equipment • Ensures proper relocation of equipment after moving, cleaning or repairs • Made of flame retardant thermoplastic resin • Virtually indestructible • Includes mounting hardware for proper installation • Designed to meet the requirements of NFPA 17A 5.6.4 2009 Edition • Patent No. US 7,581,623 NEW POST -SET'"' Models! K Model Installation Kit Order with these model numbers when you only want the kit: Elbows* • All Elbows are in compliance with ASTM standards *Use of Street Els not recommended in Canada C12 Adjustment of Ansul fire control system, by PRD C13 Montague Range Accessories Specifications: Montague Range Accessories General Information: Added to Montague basic equip- ment, these accessories enhance the overall smooth appearance of your cooking battery and save many hours of cleaning. Perfectly matched, all units can be pre -assembled and installed from the front after ranges are in place. Single and double Hi -Shelves and 18" Hi -Backs install without the use of nuts, bolts, screws or tools. Hi -Shelf "Lips": A special lip running across the bottom of Hi -Shelves collects grease and moisture, depositing it on the range where it can be easily removed ... not down the back of the range. Hidden Flues: Specially -designed flues within Montague Hi -Shelves distribute even warmth throughout every ❑ DOUBLE HI•SHELF 0 12" AND 18" APRON FRONTS square inch of shelf area. Ideal temperatures are main- tained for heating plates and keeping food warm. Hi -Shelf Construction: Sturdy, double-wall design of Montague Hi -Shelves and Hi -Backs eliminates grease - trapping cracks, speeds cleanup. Special Fry Tops: Montague offers extra -length Fry Tops in 48", 54", 60" and 72" widths and cooking depths of 28" and 34". Standard 3/4" thick; or 1" thick (optional). These cover multiple -range combinations and Mon- tague Add -A -Unit sections. Dimensions: See other side. Note: Design improvements may affect change to speci- fications without notice. The Montague Company, 792 Montague Ave., San Leandro, California 94577 • Telephone 415-351-9162 • Telex 34-0528 0 18' HI -BACK 0 DOORS FOR LESS OVEN ❑ 12" AND 18" SPREADER PLATES Montague Range Accessories 236" Specifications: Montague Range Accessories T A" 22.9 13'4"( r T 20" 50.8 Flue - 216"• RANGE TOP 30.5 95.7 61 DOUBLE HI -SHELF (OPTIONAL) 12" 18" OF 24" T 216" 230\1' s� 18" 20 3/B" 95.7 51,8 HI -BACK (OPTIONAL) ABOVE AVAILABLE IN 12", 18", 24" AND 36" WIDTHS, AND ONE- PIECE SECTIONS UP TO 108" TO MOUNT OVER A RANGE BATTERY. FOR 34" DEEP RANGE ... 34 114" FOR 40" DEEP RANGE ... 40.1/4" SPREADER PLATES 12" 18" Of 24" APRON FRONTS -r— 2316' ?1. 53.3 59. 7 TOP VIEW SIDE VIEW OPTIONAL 3/4" OR 1" REAR GAS CONNECTION CASTE RS 2y2" t RANGE TOP. STUB BACK I STO.1 + FOR 36" 2 DOORS 1T 34" EA. FOR 24" ADD -A -UNIT 1 DOOR ... 23 /4' I ~ 011 FOR 18" ADD -A -UNIT SINGLE 000R.173/4" r — FOR 12" ADD -A -UNIT SINGLE DOOR 11 3/4" DOORS FOR LESS OVEN 34" 6 40" DEPTH FRY SURFACE 48", 54". 60" 8 72" WIDE. 11.4 EXTRA WIDE ONE-PIECE FRY TOPS FOR BATTERY ARRANGEMENTS. Black Numbers Centimeters Commercial Cooking Equipment Since 1857 ADVANCE TABOO. SMART FABRICATION'. STAINLESS STEEL DROP-IN SINKS One Compartment - FOR HAND SINK USE Sinks Includes Gooseneck Faucet & Drain C14 Item #: Qty #: Model #: Project #: FEATURES: One piece seamless Deep Drown sink bowl design. All sink bowls have a large liberal radii with a minimum dimension of 2" and are rectangular in design for increased capacity. Self -Rim Design. Mounting clips provided accomodate all thicknesses of counter. (Quantity supplied varies based on drop in sink ordered). Includes 4" 0.C. K-52 faucet & basket drain. CONSTRUCTION: Unit fabricated from one sheet of stainless steel. All bowls are Sound Deadened. Units feature Advance Tabco's Smart Finishh. MECHANICAL: Faucet supply is 1/2" IPS male thread. Deck mounted faucet is furnished with aerator and 4" 0.C. MATERIAL: 20 gauge type 304 series stainless steel. Faucets are brass -nickel plated. Stainless Steel 1-1/2" IPS basket drain. STANDARD MOUNTING CLIPS accomodate all thicknesses of counter. Replacement # K-28 (Per Sink) Available Faucets & Accessories Model # Qty Deck Mounted 3 1/2" Gooseneck. 4" 0.C. K-52 Deck Mounted 81/2" Gooseneck. 4" 0.C. K-55 Deck Mounted Swing w/Spray. 8" 0.C.* K-58 Deck Mtd. X.H.D. 3 1/2" Gooseneck. 4" 0.C. K-62 Mounting Clips (Bag of 4). K-28 *REQUIRES K-472 FAUCET HOLE REVISION DI -1-5 DI-1-5SP DI -1-25 DI -1-10 DI -1-35 Standard Faucet conforms to NSF 61 Standard 9. An optional faucet upgrade is required for compliance to AB 1953 Standards. For Replacement Faucets & Upgrades, Drains & Accessories visit our website at www.advancetabco.com Customer Service Available To Assist You 1-800-645-3166 8:30 am - 8:00 pm E.S.T. Email Orders To: customer@advancetabco.com. For Smart Fabrication"Quotes, Email To: smartfab@advancetabco.com or Fax To: 631-586-2933 ADVANCE TABCO. NEW YORK GEORGIA TEXAS NEVADA SMART FABRICATION'• www.advancetabco.com Fax: (631) 242-6900 Fax: (770) 775-5625 Fax: (972) 932-4795 Fax (775) 972-1578 A-1 TOL ± .125" DIMENSIONS and SPECIFICATIONS Supplied with K-52 Faucet ALL DIMENSIONS ARE TYPICAL DI -1-5 Faucet DI -1-25 Cut -Out Size 11 1/4a x 1s ( 5• -- z• a i :?. 1/4" radius corr nerers corners is Approx. Wt. 12 lbs. -12-- J;, Faucet ii DI-1-5SP l.__ L % 5- l_ �,_.i 2 '- 21 Approx. Wt. 8 lbs. 6.. „ Approx. Pp -I Wt. 16 lbs. 102„ DI -1-35 DI -1-10 Faucet "\ - Cut -Out Size 16 1/4" x 14 1/4" 1 1/4" radius corners 10' I I i i I 15"( f 10" ;COY I Approx. Wt. 14 lbs. F-.- 101/2' mc. Faucet-- __....._....._ 5' I ` r DI-1-10SP 10" y �' a 1�n, Approx. Wt. 10 lbs. 0 6" 6" I 10" r 102" _ TYPICAL INSTALLATION OVERALL DIMENSION (O.D) Approx. Wt. 18 lbs. DI TOP VIEW FOR TOP VIEW FOR -1-5 & DI -1-10 DI-1-5SP & DI-1-10SP r O L, 0 0 ,,;,"",•ii 1;, m 1s" t4•.,, 10 —� �' Cut -Out Size 12 1/4" x 18 1/4" 19" 1 1/4" radius corners T 14b 10" - CUTOUT DIMENSION - -3/4") Cut -Out Size = L to R x F to B �. _r_c` 13" - I— 13"—H ADVANCE TABOO. 6M/WT FAFo�'ATIpN'• A- la 200 Heartland Boulevard, Edgewood, NY 11717-8380 ADVANCE TABCO is constantly engaged in a program of improving our products. Therefore, we reserve the right to change specifications without prior notice. © ADVANCE TABCO, JUNE 2012 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax: 864-834-3518 www.tsbrass.com Model No. B-1141 Item No. C14a This Space for Architect/Engineer Approval Job Name Date Model Specified Quantity CustomerNVholesaler Contractor Architect/Engineer f�7 ADA Compliant 133X Swivel Gooseneck w/ B -PT Stream Regulator Polished Chrome Plated Escutcheon —Lever Handles w/ Color Coded Indexes 7 3/8" [187mm] 5 3/4" [146mm] 11 3/8" [289mm] r[25mm] Mounting Surface 4" [102mm] 1/2" NPT Male Shanks (Requires 0 1" [ 25mm] Cutouts) 150A Tailpiece and Nut Furnished for 1/4" NPT Connection 1/4" [6mm] Max. Mounting Surface Thickness Product Specifications: 4" Inlet Centers Deck Mount Workboard Mixing Faucet w/ Lever Handles, 133X Swivel Gooseneck Assembly, B -PT Stream Regulator & 1/2" NPT Male Shanks Drawn KJG Checked DHL Approved JHB Scale: 1, :4 Date: 09/29/08 Sheet: 1 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 REG. #A2601 ISO #9001 Travelers Rest, SC: 800-476-4103 Simi Valley, CA: 800-423-0150 Fax. 864-834-3518 www.tsbrass.com Model No. B-1141 Item No. Lti F91 ITEM NO. SALES NO. DESCRIPTION 1 133X Swivel Gooseneck Assembly 2 001048-45 Nozzle Tip Washer 3 000922-45 Lever Handle Screw 4 001661-45 Red Index -HW 5 001638-45 Lever Handle 6 009749-25 Bonnet Nut 7 009753-25 B-1100 RH Spindle Assembly 8 000763-20 Seat 9 000712-25 Escutcheon Lock Nut 10 001258-40 Escutcheon 11. B -PT Stream Regulator Outlet 12 009538-45 Swivel Washer. 13 011429-45 14 001074-45 Swivel Sleeves (2) 0 -Ring 15 001660-45 Blue Index -CW 16 009754-25 B-1100 LH Spindle Assembly 17 000999-45 Brass Lock Washer 18 002954-45 Shank Lock Nut 19 150A Bag of (1) Nut & (1) Tailpiece Product Specifications: 4" Inlet Centers Deck Mount Workboard Mixing Faucet w/ Lever Handles, 133X Swivel Gooseneck Assembly, B -PT Stream Regulator & 1/2" NPT Male Shanks Drawn KJG Checked DHL Approved JHB Scale: NTS Date: 09/29/08 ISheet: 2 of 2 C15 Relocated coffee brewer, by Owner • C16 Dishtables - "C10" Series Backsplash - Compartment Sink Design Part # - TCDT###-##-1# Typical of unit supplied by PRDCI) 30.00 24.00 l Sink Width (18" or 24") 34.00 21.00 Features: "Standard" / 16 Gau • e Construction "S • ec-Line" / 14 Gau • e Construction 16 Gauge Type 304 Stainless Steel Construction • "H" Leg Assembly - 1 5/8" Legs w/ 1" Stretchers # 4 Satin Finish • 14 Gauge Type 304 Stainless Steel Construction • "H" Leg Assembly - 1 5/8" Legs and Stretchers • #4 Satin Finish • Tops are undercoated with NSF Sound Deadening Compound General Description: • 10" x 2" Backsplash , 45° return, with 1/2" turn down for mounting to wall clip • 220° sanitary rolled rim on all free edges * Sinks available in 18" or 24" wide by 24" front to back. All sink bowls are 12" deep. * All sinks come with basket drains and brackets for optional lever wastes • Faucet holes punched in backsplash on 8" centers Options: Model Number U/M NSF Encore Pre -Rinse, Deck Mount, with Wall Bracket NSF Encore Pre -Rinse, Wall Mount, with Wall Bracket Twist Handle Waste Outlet, Opening 3.5", Drain Size 2" Twist Handle Waste Outlet w/ Overflow, Opening 3.5", Drain Size 2" Removable Stainless Steel Rack Slide Stainless Steel Undershelf available at an additional cost CHGKN50-1000-BR CHGKN53-1000-BR CHGD50-7200 CHGD50-7215 SSRS Orders Phone 888-618-2122 Fax 503-397-9596 www.pacificstainless.com Each Each Each Each Set of 3 Pacific Stainless PRODUCTS, INC. • Dishtables "C10" Series - Compartment Sink Design - Soiled Dishtable 24"x24" x 12" Sir Right Hand SIZE I MODEL 84" TCDT 84 -24-16 -R 96" TCDT 96 -24-16 -R 120" TCDT 120 -24-16 -R 144" TCDT 144 -24-16 -R 24" x 24" x 12" SI Left Hand SIZE I MODEL 84" TCDT 84 -24-16 -L 96" TCDT 96 -24-16 -L 120" TCDT 120 -24-16 -L 144" TCDT 144 -24-16 -L Phone 888.618.2122 Fax 503.397.9596 E-mail info(Dpacificstainless.com PROCtilit3T4. ttWt •• • T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com Model No. B-0231 Item No. C16a 12 7/16" [315mm] ADA Compliant 062X 12" Swing Nozzle w/ Stream Regulator Outlet Eterna Cartridges & Lever Handles w/ Colored Coded Indexes This Space for Architect/Engineer Approval Job Name Date Model Specified Customer/Wholesaler Contractor Quantity Architect/Engineer 12" [ 305mm ] 7 1/2" [ 190mm ] 3 9/16" 4 3/4" [91mm] [121mm] 8" [ 203mm ] Adjustable From 7 3/4" to 8 1/4" [197mm to 210mm] 0 2" [51 mm] Flanges w/ 1/2" NPT Female Inlets 2 3/8" [61mm] Mounting Surface Product Specifications: 8" Wall Mount Mixing Faucet w/ Eterna Cartridge, Lever Handles, 12" Swing Nozzle w/ Stream Regulator Outlet & 1/2" NPT Female Inlets Drawn DHL Checked DMH Approved JHB Scale: 1:4 Date: 02/11/13 Sheet: 1 of 2 T&S BRASS AND BRONZE WORKS, INC. 2 Saddleback Cove / P.O. Box 1088 Travelers Rest, SC 29690 Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com Model No. B-0231 Item No. ITEM NO. SALES NO. DESCRIPTION 1 062X 12" Swing Nozzle w/ B -PT Stream Regulator Outlet 2 001048-45 Nozzle Tip Washer 3 B -PT Stream Regulator Outlet 4 001661-45 Red Index -HW 5 005960-40 Eterna Cartridges, RTC 6 009538-45 Swivel Washer 7 011429-45 Swivel Sleeves (2) 8 001074-45 0 -Ring 9 000922-45 Lever Handle Screw 10 001660-45 Blue Index -CW 11 001638-45 Lever Handle 12 005959-40 Eterna Cartridges, LTC 13 00AA 1/2" NPT Female Eccentric Flange 14 001019-45 Coupling Nut Washer Product Specifications: 8" Wall Mount Mixing Faucet w/ Eterna Cartridge, Lever Handles, 12" Swing Nozzle w/ Stream Regulator Outlet & 1/2" NPT Female Inlets Drawn DHL Checked DMH Approved JHB Scale: NTS Date: 02/11/13 l Sheet: 2 of 2 ADERMIT COORD COPY � PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-102 DATE: 08/20/13 PROJECT NAME: NORDSTROM SITE ADDRESS: 100 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: glic) Building Division �PS W r 9j P) ublic o Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 08/22/13 Not Applicable Comments: Permit' Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/19/13 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: PERMIT COORD COPY 111 PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-102 DATE: 07/16/13 PROJECT NAME: NORDSTROM SITE ADDRESS: 100 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued EPARTMENTS: Building Division ,9-P Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07/18/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 1Y1 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/15/13 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: PermitrCenter Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: PROJECT NAME:0 — w -k S ,, ' SITE ADDRESS: CQ sa-JM,cyja,4-.t.,, Kt/ PERMIT NO: `—' r(-) ( 1 0 ORIGINAL ISSUE DATE: B _) O-,( 3 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS t g -10- AtVA (fA,1) VVI' 8-).P -( 5_ Summary of Revision: G 4 e1 c 0 -CC k PY Summary of Revision: a LAI tNa.&L s hitt Received by: /e"`i 5/0,47W REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: G 4 e1 c 0 -CC k PY p Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ° l3 /1-13 13 Plan Check/Permit Number: PGL? — /02. ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Et Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: N 01r 41 J "+-. 1•61".1-1, C e'd (...T - - ( /gG hi 04_1 d Project Address: /0 0 b L-4,-. ccp. -6 v 14 oloroikA, GQ..,, it 1. , Tc., Ic L.. i /a) t•04 TCf 4 Contact Person: (2.42-a ti Co ►^w its Phone Number: 2.06# 436. — 64-2_./ Summary of Revision: 4 4 Ze-st. it de w..0 -tali. lc re /jc. c.1 f t.. Aori, /Ai 41 k �+ -o tij 4 . eel- n i€ e 414.4i . RECErtrm CITY OF 3'UKWILA OCT 0 3 2013 AER 4G'9'r:Ear' q. /212'Z 9-/ J/'i S cid' v✓!�r� Sheet Number(s): f'I# 2 - "Cloud" "Cloud" or highlight all d'reas'of revisio rincIiiding date of revision' Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on H:\Applications\Forms-Applications On Line V010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.Tukwi1aWA.gov • Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 08/20/2013 Plan Check/Permit Number: PG13-102 Response to Incomplete Letter # Response to Correction Letter # ✓ Revision # 01 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Nordstrom Southcenter Cafe Remodel Project Address: 100 Southcenter Mall, Tukwila, WA 98188 Contact Person: Ross Garvey Phone Number: (206) 571-0180 Summary of Revision: Addition of (1) hand wash sink. Sheet Number(s): P1.1 & P1.2 neeetveo !`.T -v or Tt_. ILA AUG, 2 0 2013 riERMI7 CENTER "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit C - nter by: Entered in Permits Plus on 2v (3 H:\Aonlications\Forms-Anolications On Line12010 Annhcatlons\7-2010- Revision Submntal.doc King County Department of Natural Resources and Parks Wastewater Treatment Division Non -Residential Sewer Use Certification • To be completed for all new sewer connections, .reconnections or change of use of existing connections: • This form does not apply to repairs or replacementsof existing sewer connections within five years of disconnect. Please Print or Type /00 5vvl tier .! "LL Property Street Address vkw11,A W4 Glity State ZIP tvErintraGL.L Owner's Name Subdivision Name Lot # Subdiv. # Block # For King County Use Only Account # No. of .RCEs Monthly Rate Property Tax ID # Party to be Billed (If different from owner)_ City or Sewer District Date of Connection Building Name SV (JAH NXg2_. /(/pI2 b rilom Side Sewer Permit # PP ) Please report any demolitions of pre-existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre-existing building? ❑Yes 0 No ❑ Was building on Sanitary Sewer? Yes ❑ No Was Sewer connected before 2/1/90? ❑Yes 0 No Sewer disconnect date: Type of building demolished? Request to apply.demolition credit to multiple buildings? 0 Yes 0 No (d a licable ZD °) C -G S5 3 Owners Phone Number Wet Area Code) ( ) Propeny Contact Phone Number (with Area Code) Owner's Mailing Address //6o/ GJJL-snj2 . ([.tib 1475 /M4G1'`e5 r GA- Too 2•C A. Fixture Units by.41'ityu.6 t New Fixture Units x Number of Fi ures = Total Fixture Units Kind of Fixture Fature Units No. of Fixtures l Fixture Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher .2 .2 . 1 2. Drinking fountain (each head) . 1 .5 (o (p Hose blbb (interior) 2.5 2.5 Clotheswasher or laundry tub . 4 2 I Sink, bar or lavatory :2 1 22 41. Sink, Clinic flushing :8 8 Sink, kitchen 3 2 5 15' Sink, other(service) 3 . 1.5 ¢ / Z Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless o o b D Water closet, lank or valve, 1.6 GPF 6 3 2 D / 2.0 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 /99 B. Other Wastewater Flow (in addition to Fixture Units, identified in Section A) Type of Facility/Process: &Att % r c; /o►•• .i�i4) Estimated Wastewater Discharge: CIT yOFV ED KWII SO Gallons/days JUL 16 2013 Residential Customer Equivalents (RCE 187 gallons per day equals 1.0 RCE !' RMIT CENTER Total Discharge (gaVday) _ 2 —IO'7-(RCE 187 C. Total Residential Custome uivalents: (add A & 8) A B 1�..IS 0, 2)- vp 1)6i; -102. 02. Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206=684.1740. I certify that the information given is corre deviation will require resubmission of corr .::rm Hort f h Signature of Owner/Representative . . Print Name of Owner/Representative 1058 (Rev. 9107) 1415 RCE 10.4 i RCE d that the capacity charge levied will be based on this information and any i ion o a revisedcapacitycharge, 1%tn,..)c d 05131 Date 7• /S' 13 White — Kina county YeIIow -Local Sewer Aoencv Pink — Sewer Customer Contractors or Tradespeople Prin.Friendly Page General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AUBURN MECHANICAL INC UBI No. 600074968 Phone 2538389780 Status Active Address Po Box 249 License No. AUBURMI163BA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 1 /1 /1984 State WA Expiration Date 9/12/2014 Zip 98071 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUBURMI184LAAUBURN MECHANICAL INC Construction Contractor Plumbing Unused 6/1/1982 1/1/1984 Archived Business Owner Information Name Role . Effective Date Expiration Date THODAY, DAVID V President 01/01/1980 Amount JOHNSON, STACY ANNE President 01/01/1980 DTC08057R723PHX12 JOHNSON, KIM PAUL Secretary 02/06/2009 Bond Information Page 1 of 2 NA-; oil 'l 8'13 Bond 3 Bond Company Name FIDELITY Et DEPOSIT CO OF MD Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date LPM8047218 09/01/2001 Until Cancelled $12,000.00 09/12/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 29 Phoenix Insurance Company, The DTC08057R723PHX12 10/01/2012 10/01/2013 $1,000,000.00 09/25/2012 28 Phoenix Insurance Company, The DTC08057R723PHX11 10/01/2011 10/01/2012 $1,000,000.0009/20/2011 27 PHOENIX INS CO DTC08057R723PHX10 10/01/2010 Until Cancelled $1,000,000.0009/27/2010 26 Continental Western Ins Co CWP258632926 10/01/2009 10/01/2010 $1,000,000.0010/05/2009 25 CONTINENTAL WESTERN INS CO CWP258632923 09/01/2008 09/01/2009 $1,000,000.0008/28/2008 24 CONTINENTAL WESTERN CWP2586329 09/01/2005 09/01/2008 $1,000,000.0008/13/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httr.c•//frrtracc aara rrnv/lni/hhin/Prilit acne OR/20/2013 SCHEDULE KITCHEN EQUIPMENT S — PLUMBING SCHEDULE WATER WASTE GAS 08-14-13 0 QTY DESCRIPTION SUPPLIERHOT COLD O D OPEN DIR. CON. MBTU REMARKS 0 3 2 -PRD GAS PIZZA OVEN STACKED - - - — - 3/4" 40 80 MBTU TOTAL, 2 -CONN. REQ'D, SEE NOTE P1 0 4 1 EXISTING GAS SIX BURNER RANGE OWNER - _ - — 1-1/4" 225 0 5 1 24" GAS BROILER PRD — — — - 1" 80 SEE NOTE P2 '9 o 1 RELOCATED KETTLE & STAND PRD _ — 1-1/2 — _ DRAIN TO FLOOR SINK 10 1 KETTLE FILLER FAUCET PRD 1/2" 1/2 - — — — 11 2 GAS CONV. OVENS - STACKED PRD — - — — 1" 60 120 MBTU TOTAL, SEE NOTE P3 0 14 1 - REPLACE HAND SINK &FAUCET REMOVE & PRD 1/2" 1/2" — 1-1/2" — — 15 0 1 RELOCATED COFFEE BREWER OWNER - 1/4" - - 1 THREE. COMP. SINK &FAUCET PRD 1/2" 1/2" - " 3 ..016 1 _ 1 HAND SINK WITH FAUCET PRD 1/2" 1/2" — 1-1/2 _ _ PLUMBINGNOTES: P1. P2. P3. PLUMBER FW PLUMBER PLUMBER PLUMBER BROILER FACTORY PLUMBER . SHALL INSTALL ALL EQUIPMENT PER LOCAL JURISDICTION. = FILTERED WATER TO CONNECT PRD SUPPLIED 3/4" FLEX HOSES TO EACH OVEN DECK. TO PROVIDE INDIVIDUAL SHUT OFF VALVES TO EACH GAS SUPPLY. TO CONNECT 1" REGULATOR AND 1" X 48"HOSE BY PRD. FLEX(PROVIDED) N WILL NOT BE COMMON MANIFOLD TO EXISTING RANGE. PROVIDES LOOSE MANIFOLD PIPING TO INTERCONNECT OVEN GAS SUPPLIES. TO INSTALL PIPING AND ATTACH PRD SUPPLIED GAS FLEX HOSE. 505 MBTU TOTAL (NEW & EXISTING) PLUMBING KEY NOTES: O1 2" GAS DOWN TO FLOOR BELOW; PROVIDE CORE DRILL AND SEAL PENETRATION WITH FIRE RATED SEALANT. CONNECT TO EXISTING 2" GAS STUB. SEE GAS RISER DIAGRAM FOR CONTINUATION. FIELD VERIFY. PROVIDE 2" GAS MANIFOLD IN EXISTING WALL FOR NEW AND EXISTING GAS EQUIPMENT. PROVIDE GAS SHUTOFF TO EACH EQUIPMENT. REFER TO EQUIPMENT SCHEDULE FOR DRAWINGS CONNECTIONS. REFER TO KITCHEN FOR OPENING UP OF WALL. O EXISTING 6 -BURNER RANGE TO REMAIN; PROVIDE NEW GAS SUPPLY. FIELD VERIFY. RELOCATED KETTLE AND STAND. MODIFY AND EXTEND 1/2" CW AND 1/2" HW TO NEW LOCATION FROM ITS EXISTING CONNECTIONS. PROVIDE PIPE INSULATION. FIELD VERIFY. 0 ROUTE 1-1/2" KETTLE DRAIN TO EXISTING FLOOR SINK. FIELD VERIFY. o6 NEW SINK AND FAUCET. CONNECT 1/2" CW, 1/2" HW AND 1-112 WTO EXISTING. PROVIDE NEW TRAP, SUPPLIES AND THERMOSTATIC MIXING VALVE/PRESSURE BALANCING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 70 EXISTING HAND SINK. PROVIDE NEW TRAP, SUPPLIES, DRAIN PIPE INSULATION AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 0 8 RELOCATED COFFEE BREWER. PROVIDE 1/2" FILTERED WATER WITH SHUTOFF VALVE. PROVIDE PIPE INSULATION. FIELD VERIFY. OPROVIDE 1/2" CW AND 1/2" HW SUPPLY TO THREE -COMPARTMENT SINK. PROVIDE PIPE INSULATION FOR HOT AND COLD WATER. o10 PROVIDE TRAP PRIMER WITH SHUTOFF TO SERVE FLOOR DRAIN. INSTALL BELOW THREE -COMPARTMENT SINK! ° CCESSIBLE LOCATION. 11 NEW FLOOR DRAIN. PROVIDE WITH TRAP PRIMER. 12 CONNECT 2" VENT TO EXISTING 2-1/2" VENT PIPING. FIELD VERIFY. 13 CONNECT 3" WASTE TO EXISTING 4" WASTE PIPING. FIELD VERIFY ROUTING. 0 14 GREASE WASTE PIPING AND VENT WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL 15 MODIFY AND CONNECT 1/2" FW FROM EXISTING WATER FILTERS. FIELD VERIFY. 0 16 GAS SHUTOFF VALVE AND ANSUL VALVE. COORDINATE. EXACT LOCATION WITH KITCHEN CONSULTANT (APPROX. 9"-12" BELOW CEILING). 0 17 CONNECT 2" GAS PIPING TO EXISTING 2" STUB LOCATED UNDER FLOOR. FIELD VERIFY. 0 18 GAS PIPING WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL 19 CONNECT 1-1/2" VENT TO EXISTING 2-1/2" VENT PIPING. FIELD VERIFY. 20 CONNECT 2" WASTE TO EXISTING 4" WASTE PIPING. FIELD VERIFY ROUTING. PLUMBING GENERAL NOTES: 1 COMPLY WITH ALL APPLICABLE CODES, STANDARDS • AND ORDINANCES, INCLUDING THE UNIFORM PLUMBING CODE (UPC) LATEST EDITION.. 2. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES AND EXISTING CONDITIONS. PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION, SERVICING OF EQUIPMENT AND THE LOCAL CODE REQUIREMENTS. 3. FIELD VERIFY ALL EXISTING PLUMBING PIPING POINT OF CONNECTIONS PRIOR TO BEGINNING WORK. PROVIDE NECESSARY OFFSETS AND/OR REROUTES TO AVOID EXISTING CONDITIONS. 4ALL DRAINAGE SHALL BE SLOPED AT 1/4 -INCH PER . LINEAL FOOT UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY DRAIN DOWN AND FILL OF EXISTING PLUMBING SYSTEMS (WATER & GAS) AS REQUIRED. PERFORM WORK TO NOT SHUTDOWN PLUMBING SYSTEMS FOR OCCUPIED AREAS DURING NORMAL WORKING HOURS. COORDINATE WITH CONTRACTOR AND NORDSTROM. 6. PLUMBING INSTALLER TO MAKE FINAL CONNECTION TO ALL EQUIPMENT. COORDINATE WITH KITCHEN EQUIPMENT INSTALLER AS REQUIRED FOR COMPLETE INSTALLATION. REFER TO KITCHEN DRAWINGS FOR EXACT ROUGH -IN LOCATIONS, SIZES AND FURTHER INFORMATION. PLUMBING INSTALLER TO PROVIDE INDIRECT WASTE PIPING, SHUT-OFF VALVES, BACKFLOW PREVENTERS, TRAPS,REGULATORS, STOPS, SUPPLIES, SUPPORTS AND ACCESSORIES REQUIRED FOR FULL OPERATIONAL INSTALLATION. 9. ALL PENETRATIONS OF PIPING THRU FLOORS, CEILING, OR. WALLS SHALL BE FIRE CAULKED AND SEALED WATER TIGHT. 10. ALL SHUT-OFF VALVES TO BE LOCATED WITHIN 12" FROM ACCESSIBLE CEILING TILE. IF NO CEILING LOCATE 10'-0" AFF. 0 21 PROVIDE 1/2" CW AND 1/2" HW SUPPLY TO HAND SINK. PROVIDE PIPE INSULATION FOR. HOT & COLD WATER AND LAVGUARD ON TRAP & SUPPLIES. FIELD VERIFY EXISTING ROUTING. 0 22 MODIFY AND EXTEND 3/4" HOT WATER PIPING TO NEW SINK AS SHOWN. PROVIDE PIPE INSULATION. 23 CONNECT 1/2" COLD WATER TO EXISTING 1/2" COLD WATER PIPING. PROVIDE PIPE INSULATION. FIELD VERIFY ROUTING. 0 NEW SINK AND FAUCET. CONNECT 1/2" CW AND 1/2" HW TO NEW PIPING. RUN 1-1/2" WASTE INDIRECTLY TO EXISTING FLOOR SINK. PROVIDE NEW TRAP (NO VENT REQUIRED), SUPPLIES AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO ." I °F. 11. RESTROOM AND KITCHEN HANDWASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT A TEMPERATURE OF AT LEAST 100 DEGREES FAHRENHEIT THROUGH A MIXING VALVE OR COMBINATION FAUCET. SELF-CLOSING OR METERING FAUCETS SHALL PROVIDE A FLOW OF WATER FOR AT LEAST 15 SECONDS. HANG 1-1/2" WASTE ALONG WALL (MIN. 8" AFF) AND DISCHARGE INDIRECTLY TO FLOOR SINK. SLOPE MIN. 1/4" / FT. CUT DISCHARGE PIPE AT 45° ANGLE. 1/2" CW Waft -SheTt— Wali Sh�ef Mac' & Bi Walk -In Freezer 2 85 2 Walk -In Cooler 3/4" HW Worki1able Slicer Wal She Worktable Filled Slant Rack Hot Food Table Worktable Wall Shelf Wal She f SEPARATE PERMIT - REQUIRED FOR; REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. %Mer hanipal rival Q lumbina et Gas Piping City of Tukwila BUILDING DIVISION CAFE REMODEL FLOOR PLAN - PLUMBING SCALE: 1/4"=1'-0" RECEIVED CITY OF TUKWILA OCT .0 3 2013 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 3 2013 171. - City of da BUILDING IVJSION FILE COPY Permit No. V (1)'--sk Plan review approval is subject to errors and omissions. Approval of construction uctlon documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fie Copy and conditions Is Elmowleddged: By_2 C.--�- 1013 /7413 n n City Ofltikwlla BUILDING DIVISION REVISION NOI.. 12 (71; I 2., PLUMBING DEMO NOTES: �A--) CAP EXISTING WATER SUPPLY TO COFFEE BREWER. FIELD VERIFY. TEMPORARILY CAP HOT AND COLD WATER SUPPLIES FOR EXISTING KETTLE FILLER FAUCET. FIELD VERIFY. REMOVE ALL EXISTING GAS PIPING FOR KITCHEN GAS EQUIPMENT. FIELD VERIFY. Issued/Revised Date Permit 06-18-13 Code Responses 08-14-13 HVAC Revisions 08-22-13 Health Dept. Review 10-01-13 O' S- 04s w Ne� N :,CI .e.oi _ 4 Li 1— 2 ' '2 o2M4 CD >r'� (1) � 0 0 O a CV 0 Z (i) w -TD. w W— Z nnrr Z ". Q SOUT CAE 100 SOUTHCEN TUKW Ov 00 ,4) r (N) KITCHEN EQUIPMENT GAS PIPING SCALE:. NONE NEW GAS PIPING PROVIDED TO SERVE EXISTING AND NEW GAS KITCHEN EQUIPMENT. 2. CALCULATIONS ARE PROVIDED TO SHOW NEW PIPING AND CONNECTED GAS LOAD DO NOT EXCEED PRESSURE DROP OF 0.5 IN-W.C.. NATURAL GAS DELIVERY PRESSURE: 6 1N.-W.C. PRESSURE DROP: 0.5 IN.-W.C. NEW CONNECTED LOAD: 1573 MBH GAS RISER DIAGRAM SCALE: NONE GAS PRESSURE DROP CALCULATIONS A H (A) SEGMENT Q (CFH) Cr TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER WITH 95/5 SOLDER OR PROPRESS FITTINGS. L (FT) D (IN.) 0H. [E] 299 FITTINGS: STANDARD WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED WROUGHT COPPER DWV (2 1/2" OR LESS). 0.6094 SCH. 40 BLACK STEEL PIPE FITTINGS: WELDED OR SCREWED WHERE APPROVED BY THE LOCAL JURISDICTIONS. 80 2.5 0.01 (F] 804 0.6094 122 3' 0.05 [H] 1573 0.6094 188 3 0.27 TOTAL PRESSURE DROP (PATH A): 0.33 IN-W.C. A T H (B) SEGMENT Q (CFH) Cr L (FT) D (IN.) AH [D] 505 0.6094 30 2 0.02 [F] 804 0.6094 122 3 0.05 [H] 1573 0.6094 188 3 0.27 TOTAL PRESSURE DROP (PATH B): 0.34 IN-W.C. CALCULATIONS PER 2009 0 381 Q IFGC 402.4(1). (EQUATION 4-1) WHERE: D = INSIDE DIAMETER OF PIPE, INCHES Q = INPUT RATE APPLIANCE(S), CFH @60F & 30 -INCH MERCURY COLUMN L = EQUIVALENT LENGTH OF PIPE, FEET AH = PRESSURE DROP, INCH WATER COLUMN Cr = 0.6094, EQUATION FACTOR D = 0.206 19.17P--= x L PLUMBING ABBREVIATIONS ABBREVIATION DESCRIPTION ABV AFF AHJ ARCH CD CVV DIA (E) ELECT EMCS FD FS FW G GPM ABOVE ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION ARCH ITECT/ARCHITECTURAL CONDENSATE DRAIN COLD WATER DIAMETER EXISTING ELECTRICAL ENERGY MANAGEMENT CONTROL SYSTEM FLOOR DRAIN FLOOR SINK FILTERED WATER NATURAL GAS, LOW PRESSURE GALLONS PER MINUTE ABBREVIATION DESCRIPTION GW GREASE WASTE GWH GAS WATER HEATER HW HOT WATER HWR HOT WATER RETURN IAPMO INTERNATIONAL ASS'N OF PLUMBING & MECHANICAL OFFICIALS IE INVERT ELEVATION (N) NC NO PSI RPBA OR RPZ SHT V IN NEW NORMALLY CLOSED NORMALLY OPEN POUNDS PER SQUARE INCH REDUCED PRESSURE BACKFLOW ASSEMBLY SHEET VENT, SANITARY WASTE, SANITARY FikE COPY Permf No.:.. %i ter, LO Plan review approval is subject to emus and omissions. Approval of construction documents does not authorz ins ' olstion of an ado fed code or ordinance. Racalpt of approved F 14 and .1 pi ' is acknowledged: Issued/Revised Date Permit Code Responses 08-14-13 BY Date �'-z7—t3 City' Of lbkwga BUILDING DIVISION PLUMBING FIXTURE CONNECTION SCHEDULE P -NO. FIXTURE WASTE VENT WATER HOT TEMPERED COLD NOTES P-11' TRAP PRIMER, PPP MODEL P2 1 1 2" A FD -3 FLOOR DRAIN, JR SMITH FIG. 2005 1-1/2" B NOTES: A. PROVIDE FLOOR DRAIN P -TRAP WITH 1/2" PRIMER CONNECTION. B. PROVIDE SQUARE TOP, 3" OUTLET AND SEDIMENT BUCKET. PLUMBING MATERIAL SCHEDULE PIPING TYPE MATERIAL REMARKS DOMESTIC WATER TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER WITH 95/5 SOLDER OR PROPRESS FITTINGS. STORM, DRAIN & WASTE STANDARD WEIGHT CAST IRON '..Jr DWV COPPER FITTINGS: STANDARD WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED' WROUGHT COPPER DWV (2 1/2" OR LESS). VENT STANDARD WEIGHT CAST IRON OR DWV COPPER FITTINGS: STANDARD WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED WROUGHT COPPER DWV (2 1/2" OR LESS). NATURAL GAS SCH. 40 BLACK STEEL PIPE FITTINGS: WELDED OR SCREWED WHERE APPROVED BY THE LOCAL JURISDICTIONS. CONDENSATE TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER DWV WITH 95/5 SOLDER OR PROPRESS FITTINGS. SEPARATE PEI _CIT F QUIPED FOR: Mechanical electrical O Plumbing O Gas Piping CI`y of Tukwila 4.111,EING DIViSKN POWERS HYDROGUARD LFe480 THERMOSTATIC MIXING VALVE W/ INTEGRAL CHECK VALVES (INSTALL ON WALL, AS HIGH AS POSSIBLE BEHIND SINK). STOP COCKS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division_ NOTE: Revisions will require a new plan submittal and may include additional plan review fes. j MANUAL FAUCET W/ HW & CW SUPPLY REVIEWED FOR CODE COMPLIANCE APPROVED AUG 232013 City of Tukwila BUILDING DIVISION SHUT-OFF VALVE UNION TRAP PRIMER IN ACCESSIBLE LOCATION MIFAB MI -TEMP AUTO PRESSURE BALANCING VALVE UNION (TYP) TO FLOOR DRAIN V U MIXING VALVE AND FAUCET PIPING DETAIL SCALE: NONE RECEIVED CITY OF TUKWILA AUG 2 0 2013 PERMIT CENTER cn W W HARGIS ENG 4-• O T- CO CO `Cr tr CO CO NN O N H U - co co w LLI CD p ILIJ LILEI UJ CC C1C " w (2:1 IL) I 11— ti ,W �¢Iw U U 4 0 Z TGALE: NONERAP PRIMER DETAIL QIO� 1\10._1. S CO 00 00 rn Date 1()2r,scale P1.1 PLUMBING DETAILS,, LEGEND AND SCHEDULES P1.2 CAFE REMODEL, FLOOR PLAN - PLUMBING 06-18-13 NONE. Drawn N.N. CAFE REMODEL PLUMBING DETAILS, LEGEND AND SCHEDULES P1.1 KITCHEN EQUIPMENT SCHEDULE PLUMBING SCHEDULE WATER WASTE GAS QTY DESCRIPTION SUPPLIER HOT COLD OPEN DIR_ CON. MBTU 1 GAS PIZZA OVEN STACKED PRD 3/4" 40 EXISTING GAS SIX BURNER RANGE OWNER 1-1/4" 225 80 MBTU TOTAL, 2 -CONN. REQ'D,: SEE NOTE P1 1 24" GAS BROILER PRD It 80 SEE NOTE P2 1 RELOCATED KETTLE &. STAND PRD 1-1/2" DRAIN TO FLOOR SINK (D. 11 1 KETTLE FILLER FAUCET PRD 1/2" 1/2" GAS CONV. OVENS - STACKED PRD 60 14 15 1 1 HAND SINK. & FAUCET - REMOVE & REPLACE RELOCATED COFFEE BREWER PRD 1/2" 1/2" 1-1/2" 120 MBTU TOTAL, SEE NOTE P3 OWNER 114" HAND SINK WITH FAUCET 0S: PLUMBER SHALL INSTALL ALL EQUIPMENT IPMENT PER LOCAL JURISDICTION. FW FILTERED WATER PRD 1/2" 1/2" 1-1/2" )- 505 MBTU TOTAL (NEW & EXISTING) P. 1 PLUMBER TO CONNECT PRD SUPPLIED3/4" FLEX HOSES TO EACH OVEN DECK. PLUMBER TO PROVIDE INDIVIDUAL SHUT OFF VALVES` TO EACH GAS SUPPLY. 48" - RAND 1"X FLEX HOSE(PROVIDED BY PRD). P2. PLUMBER TO CONNECT 1" REGULATOR �.. BROILER WILL NOT BE COMMON MANIFOLD TO EXISTING RANGE. P3. FACTORY PROVIDES LOOSE MANIFOLD PIPING TO INTERCONNECT OVEN GAS SUPPLIES. IES. PLUMBER. TO INSTALL PIPING AND ATTACH PRD SUPPLIED GAS FLEX HOSE. PLUMBING KEY NOTES: 1 2"GAS DOWN TO FLOOR BELOW; PROVIDE CORE O DRILL AND SEAL PENETRATION WITH FIRE RATED SEALANT. CONNECT TO EXISTING 2" GAS STUB. SEE GAS RISER DIAGRAM FOR CONTINUATION. FIELD VERIFY. O 2 PROVIDE 2" GAS MANIFOLD IN EXISTING WALL FOR NEW AND EXISTING GAS EQUIPMENT. TO EACH EQUIPMENT. PROVIDE GAS SHUTOFFQ REFER TO EQUIPMENT SCHEDULE FOR CONNECTIONS. REFER TO KITCHEN DRAWINGS FOR OPENING UP OF WALL. 30 EXISTING 6 -BURNER RANGE TO REMAIN; PROVIDE NEW GAS SUPPLY. FIELD VERIFY. O4 RELOCATED KETTLE AND STAND. MODIFY AND EXTEND 1/2" CW AND 1/2" HW TO NEW LOCATION FROM ITS EXISTING CONNECTIONS. PROVIDE PIPE INSULATION. FIELD VERIFY. 5 ROUTE 1-1/2" KETTLE DRAIN TO EXISTING FLOOR SINK. FIELD VERIFY. 0 6 NEW SINK AND FAUCET. CONNECT 1/2" CW, 1/2" HW AND 1-1/2" W TO EXISTING. PROVIDE NEW TRAP, SU MIXING VALVE (PER DETAIL 2 TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 07 EXISTING HAND SINK. PROVIDE NEW TRAP, SUPPLIES, DRAIN PIPE INSULATION AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. RELOCATED COFFEE. BREWER. PROVIDE 1/2" FILTERED WATER WITH SHUTOFF VALVE. PROVIDE PIPE INSULATION. FIELD VERIFY. PLUMBING GENERAL NOTES: PROVIDE 1/2"CW AND 1/2"SUPPLYNWTO THREE -COMPARTMENT SINK. PROVIDE PIPE INSULATION FOR HOT AND COLD WATER. 10 PROVIDE TRAP PRIMER WITH SHUTOFF TO SERVE FLOOR DRAIN. INSTALL BELOW THREE -COMPARTMENT SINK IN ACCESSIBLE LOCATION. 0 11' NEW FLOOR DRAIN. PROVIDE WITH TRAP PRIMER. O 12 CONNECT 2" VENT TO EXISTING 2-1/2" VENT PIPING. FIELD VERIFY. 13 CONNECT 3" WASTE TO EXISTING 4" WASTE PIPING. FIELD VERIFY ROUTING. O 14 • GREASE WASTE PIPING AND VENT WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL 15 MODIFY AND CONNECT 1/2" FW FROM EXISTING WATER FILTERS. FIELD VERIFY. O 16 GAS SHUTOFF VALVE AND ANSUL VALVE. COORDINATE EXACT LOCATION WITH KITCHEN CONSULTANT (APPROX. 9"-12" BELOW CEILING). COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES, INCLUDING THE UNIFORM PLUMBING f C ES CODE' (UPC) LATEST EDITION. 2. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES AND EXISTING CONDITIONS. PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL. DESIGN, PROPER OPERATION, SERVICING OF EQUIPMENT AND THE LOCAL CODE REQUIREMENTS. 3. FIELD VERIFY ALL EXISTING PLUMBING PIPING POINT OF CONNECTIONS PRIOR TO BEGINNING WORK. PROVIDE NECESSARY OFFSETS AND/OR REROUTES TO AVOID EXISTING CONDITIONS. 4. ALL DRAINAGE SHALL BE SLOPED AT 114 -INCH PER LINEAL FOOT UNLESS OTHERWISE. NOTED. ANDFILLOF 5. PROVIDE ALL NECESSARY DRAINDOWN EXISTING PLUMBING SYSTEMS (WATER & GAS) AS REQUIRED. PERFORM WORK TO NOT SHUTDOWN PLUMBING SYSTEMS FOR OCCUPIED AREAS DURING NORMAL WORKING HOURS. RS. COORDINATE WITH CONTRACTOR AND NORDSTROM. 6. PLUMBING INSTALLER TO MAKE FINAL CONNECTION S TO ALL EQUIPMENT. COORDINATE WITH KITCHEN EQUIPMENT INSTALLER AS REQUIRED FOR COMPLETE INSTALLATION. 17' CONNECT 2" GAS PIPING TO EXISTING 2" STUB LOCATED UNDER FLOOR. FIELD VERIFY. o LOCATED 18 GAS PIPING WHERE SHOWN OCATED UNDER FLO•R. Y C TOEXISTING 2-1/2"VENT (I) CONNECT 1-1/2"VENT CONNE PIPING. FIELD VERIFY. O 20 CONNECT 2" WASTE TO EXISTING 4" WASTE PIPING. FIELD VERIFY ROUTING. 21 PROVIDE 1/2" CW AND 1/2" HW SUPPLY TO HAND SINK. PROVIDE PIPE INSULATION. 0 T .N+ CSL'`W°T R. REFER TO KITCHEN DRAWINGS FOR EXACT ROUGH -IN LOCATIONS, SIZES AND FURTHER INFORMATION. 8. PLUMBING INSTALLER TO PROVIDE INDIRECT WASTE PIPING, SHUT-OFF VALVES, BACKFLOW PREVENTERS,. TRAPS,REGULATORS, STOPS, SUPPLIES, SUPPORTS AND ACCESSORIES REQUIRED FOR FULL OPERATIONAL INSTALLATION. ALL PENETRATIONS OF PIPING THRU FLOORS, CEILING, OR WALLS SHALL BE FIRE CAULKED AND SEALED WATER TIGHT. ALL SHUT-OFF VALVES TO BE LOCATED WITHIN 12" FROM ACCESSIBLE CEILING TILE. IF NO CEILING 0 1a' -I" F 11. RESTROOM AND KITCHEN HANDWASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT A TEMPERATURE OF AT LEAST 100 DEGREES FAHRENHEIT THROUGH A MIXING VALVE OR COMBINATION FAUCET. SELF-CLOSING OR. METERING FAUCETS SHALL PROVIDE A FLOW OF WATER FOR AT LEAST 15 SECONDS. 3 / " V L PPY s WATER HEAT E 514" H ' Ogip_ f 3/4" HWR UP -E. ISM`: abinet' Lift ruc all Wail —Sfieft- SREEN EL' ED !N PLACE, Walk -In Freezer -1/2" Walk -In Cooler Wal She f Worktable 4q G /Slant Rack (E) !!..GW TO BUILDING'S GREASE INTER EP__InOR Worktable Wall Shelf REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 3 2013 City of Tukwila BUILDING DIVISION PLUMBING DEMO NOTES: CAP EXISTING WATER SUPPLY TO. COFFEE BREWER. FIELD VERIFY. Clip TEMPORARILY CAP HOT AND COLD WATER SUPPLIES FOR EXISTING KETTLE FILLER FAUCET. FIELD VERIFY. `') REMOVE ALL EXISTING GAS PIPING FOR KITCHEN GAS EQUIPMENT. FIELD VERIFY. CAFE REMODEL FLOOR PLAN - PLUMBING SCALE: 1/4"=1'-0" RECEIVED CITY OF TUKWILA AU3 2 0 Z7,i3 PERMIT CENTER Issued/Revised Date Permit 06-18-13 Code Responses 08-14-13 ,,. 20657 , 10vaL •U Z 4) OOO' N N- in vo0OOco Md1' N d' d' NOO O O co (I) N N; ca p0CD I-- LLu). ft W W —nn (9= Z W cn 'V 1 SOUT CAI 100 SOUTHCEN TUKW 000 0-4'1N IES. G �g ps BO1‘AB') -ST("),/o()1:400) (N) KITCHEN EQUIPMENT GAS PIPING SCALE: NONE 1\4 NATURAL GAS DELIVERY PRESSURE: 6 IN.-W.C. PRESSURE DROP: 0.5 IN.-W.C. NEW CONNECTED LOAD: 1573 MBH GAS RISER DIAGRAM SCALE: NONE NOTES: NEW GAS PIPING PROVIDED TO SERVE EXISTING AND NEW GAS KITCHEN EQUIPMENT. 2. CALCULATIONS ARE PROVIDED TO SHOW NEW PIPING AND CONNECTED GAS LOAD DO NOT EXCEED PRESSURE DROP OF 0.5 IN-W.C.. SEPARATE PERMIT REQUIRED FOR: leMschanical I Iectricat ❑ Plumbing CI Gas Piping Clty of Tukwila BUNG DIVISION GAS PRESSURE DROP CALCULATIONS A T H (A) SEGMENT Q (CFH) Cr FIXTURE L (FT) D (IN:) All [E] 299 TEMPERED 0.6094 STANDARD WEIGHT CAST IRON OR DWV COPPER 80 2.5 0.01 [F.] 804 TYPE L COPPER TUBING 0.6094 P-11 122 3 0.05 [H] 1573 1 / 2" 0.6094 FD -3 188 3 0.27 — — TOTAL PRESSURE DROP (PATH A): 0.33 IN -W. C. NOTES: A. PROVIDE FLOOR DRAIN P -TRAP WITH 1/2" PRIMER CONNECTION, B. PROVIDE SQUARE TOP, 3" OUTLET AND SEDIMENT BUCKET. CAFE REMODEL PLUMBING DETAILS, LEGEND AND SCHEDULES P1.1 A T H (B) SEGMENT : Q (CFH) Cr L (FT) D (IN.) LIN [D] 505 0.6094 30 2 0.02 [F] 804 0;6.094 122 3 0.05' [H] 1573 0.6094 188 3 0.27 TOTAL PRESSURE DROP (PATH B): 0.34 IN-W.C. CALCULATIONS PER 2009 0381 Q IFGC 402.4(1). (EQUATION 4-1) WHERE: D = INSIDE DIAMETER OF PIPE, INCHES Q = INPUT RATE APPLIANCE(S), CFH 60F & 30 -INCH MERCURY COLUMN L = EZiUIVALENT LENGTH OF PIPE, FEET A = PRESSURE DROP, INCH WATER COLUMN Cr = 0.6094, EQUATION FACTOR D = 19.1.7 0.2os Crux L� PLUMBING ABBREVIATIONS ABBREVIATION DESCRIPTION ABV AFF AHJ ARCH CD CW DIA (E) ELECT EMCS FD FS FW G GPM ABOVE ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION ARCHITECT/ARCHITECTURAL CONDENSATE DRAIN COLD WATER DIAMETER EXISTING ELECTRICAL ENERGY MANAGEMENT CONTROL SYSTEM FLOOR DRAIN FLOOR SINK FILTERED WATER NATURAL GAS, LOW PRESSURE GALLONS PER MINUTE ABBREVIATION GW GWH HW HWR IAPMO IE (N) NC NO PSI RPBA OR RPZ SHT VW DESCRIPTION GREASE WASTE GAS WATER HEATER HOT WATER HOT WATER RETURN INTERNATIONAL ASS'N OF PLUMBING & MECHANICAL OFFICIALS INVERT ELEVATION NEW NORMALLY CLOSED NORMALLY OPEN POUNDS PER SQUARE INCH REDUCED PRESSURE BACKFLOW ASSEMBLY SHEET VENT, SANITARY WASTE, SANITARY FIV COPY Perri 1%•4-10X Pias r +v`ew approval is subject to errors and omissions. a� . 4,7 J,,3 of construction documents does not authorize of any adopted code or ordinance. Receipt l ;,.gir lved Field py and cordons is acknowledged: By Date: 17-01 City Of lbkwlla PLUMBING MATERIAL PLUMBING FIXTURE CONNECTION SCHEDULE BUILDING D: PIPING TYPE P -NO. FIXTURE WASTE VENT WATER NOTES HOT TEMPERED COLD STANDARD WEIGHT CAST IRON OR DWV COPPER FITTINGS: STANDARD WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED WROUGHT COPPER DWV (2 1/2" OR LESS): NATURAL GAS SCH. 40 BLACK STEEL PIPE FITTINGS: WELDED OR SCREWED WHERE APPROVED BY THE LOCAL JURISDICTIONS. CONDENSATE TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER DWV WITH 95/5 SOLDER OR PROPRESS FITTINGS. P-11 TRAP PRIMER, PPP MODEL P2 — — — - 1 / 2" A FD -3 FLOOR DRAIN, JR SMITH FIG. 2005 2" 1-1/2"' — — — B NOTES: A. PROVIDE FLOOR DRAIN P -TRAP WITH 1/2" PRIMER CONNECTION, B. PROVIDE SQUARE TOP, 3" OUTLET AND SEDIMENT BUCKET. PLUMBING MATERIAL Date SCHEDULE PIPING TYPE MATERIAL REMARKS DOMESTIC WATER TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER WITH 95/5 SOLDER OR PROPRESS FITTINGS. STORM, DRAIN & WASTE STANDARD WEIGHT CAST IRON OR DWV COPPER FITTINGS STANDARD` WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED WROUGHT' COPPER DWV (2 1/2" OR LESS). VENT STANDARD WEIGHT CAST IRON OR DWV COPPER FITTINGS: STANDARD WEIGHT CAST IRON WITH NO HUB JOINTS OR SOLDERED WROUGHT COPPER DWV (2 1/2" OR LESS): NATURAL GAS SCH. 40 BLACK STEEL PIPE FITTINGS: WELDED OR SCREWED WHERE APPROVED BY THE LOCAL JURISDICTIONS. CONDENSATE TYPE L COPPER TUBING FITTINGS: WROUGHT -COPPER DWV WITH 95/5 SOLDER OR PROPRESS FITTINGS. LandLREVISIONS No changes shall be made to the scope of work `without prior approval of Tukwila Building Division. E Rovisions will require a new plan submittal and may include additional plan review fees. j POWERS HYDROGUARD LFe480 THERMOSTATIC MIXING VALVE W/ INTEGRAL CHECK VALVES (INSTALL ON WALL, AS HIGH AS POSSIBLE BEHIND SINK). STOP COCKS. MANUAL FAUCET W/ HW & CW SUPPLY TYPICAL HAND SINK 1/2" COLD WATER. SUPPLY MIXING VALVE AND FAUCET PIPING DETAIL SCALE: NONE SION REVIEWED FOR CODE COMPLIANCE APPROVED IJUL 2 9 2013 VVl City of 'Tukwila BUILDING DIVISION SHUT-OFF VALVE UNION TRAP PRIMER IN ACCESSIBLE LOCATION 12" MIN. TO FLOOR DRAIN TRAP PRIMER DETAIL. SCALE: NONE RECEIVEn IJUL 18 2013 TUKVv, PUBLIC WORKS RECEIVED CITY OF TUKWILA JUL 1 6 2013 PER,1d17 CENTER 17 \ ,0—• tQz DRAWING INDEX P1.1 PLUMBING DETAILS, LEGEND AND SCHEDULES P1.2 CAFE REMODEL, FLOOR PLAN - PLUMBING Issued/Revised Date Permit 06-18-13 ty. �o �, 20657 .,4 CNA (yl /oh . U o�S M d - 0) Nr Nr ,q- ANN n l cin cc ID Is W 2 O W', cn o ?� �. � 0 5NOCo ZO`1) - LLI'; o HARGIS 1 El S Date 06-18-13 Scale NONE Drawn N.N. CAFE REMODEL PLUMBING DETAILS, LEGEND AND SCHEDULES P1.1 PLUMBING KEY NOTES: 0 1 2" GAS DOWN TO FLOOR BELOW; PROVIDE CORE DRILL AND SEAL PENETRATION WITH FIRE. RATED. SEALANT. CONNECT TO EXISTING 2" GAS STUB. SEE GAS RISER DIAGRAM FOR CONTINUATION. FIELD VERIFY. 2 PROVIDE 2" GAS MANIFOLD IN EXISTING WALL FOR. NEW AND EXISTING GAS EQUIPMENT. PROVIDE GAS SHUTOFF TO EACH EQUIPMENT. REFER TO EQUIPMENT SCHEDULE FOR CONNECTIONS. REFER TO KITCHEN DRAWINGS FOR OPENING UP OF WALL. 0 3 EXISTING 6 -BURNER RANGE TO REMAIN; PROVIDE NEW GAS SUPPLY. FIELD VERIFY. 0 4 RELOCATED KETTLE AND STAND. MODIFY AND EXTEND 1/2" CW AND 1/2r, HW TO NEW LOCATION FROM ITS EXISTING CONNECTIONS. PROVIDE PIPE INSULATION. FIELD VERIFY. 0 5 ROUTE 1-1/2" KETTLE DRAIN TO EXISTING FLOOR SINK. FIELD VERIFY. NEW SINK AND FAUCET. CONNECT 1/2" CW, 1/2" HW AND 1-1/2" WTO EXISTING. PROVIDE NEW TRAP, SUPPLIES AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 0 7 EXISTING HAND SINK, PROVIDE NEW TRAP, SUPPLIES, DRAIN PIPE INSULATION AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 0 RELOCATED COFFEE BREWER. PROVIDE 1/2" FILTERED WATER WITH SHUTOFF VALVE. PROVIDE PIPE INSULATION. F D VERIFY. 1/2"HW SUPPLY 1/2"CW AND TO THREE -COMPARTMENT SINK. PROVIDE PIPE INSULATION FOR HOT AND COLD WATER. 0 10 PROVIDE TRAP PRIMER WITH SHUTOFF TO SERVE FLOOR DRAIN. INSTALL BELOW THREE -COMPARTMENT SINK IN ACCESSIBLE LOCATION. 0 11 NEW FLOOR DRAIN. PROVIDE WITH TRAP PRIMER. 0 12 CONNECT 2" VENT TO EXISTING 2-1/2" VENT PIPING. FIELD VERIFY. o 13 CONNECT 3"WASTE TO EXISTING 4"WASTEVERIFY ROUTING. PIPING. FIELD E 0 14 GREASE WASTE PIPING AND VENT WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL 0 15 MODIFY AND CONNECT 1/2" FW FROM EXISTING WATER FILTERS. FIELD VERIFY. 0 16 GAS SHUTOFF VALVE AND ANSUL VALVE. COORDINATE EXACT LOCATION WITH KITCHEN CON ULTANT( -APPROX. 9"-12" BELOW CEILING). 0 17 CONNECT 2" GAS PIPING TO EXISTING 2" STUB LOCATED UNDER FLOOR. FIELD VERIFY. 0 18 GAS PIPING WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL PLUMBING GENERAL NOTES: 1 COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES, INCLUDING THE UNIFORM PLUMBING. CODE (UPC) LATEST EDITION. 2. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES AND EXISTING CONDITIONS. PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION, SERVICING OF EQUIPMENT AND THE LOCAL CODE REQUIREMENTS. 3. FIELD VERIFY ALL EXISTING PLUMBING PIPING POINT OF CONNECTIONS PRIOR TO BEGINNING WORK. PROVIDE NECESSARY OFFSETS AND/OR REROUTES TO AVOID EXISTING CONDITIONS. 4. ALL DRAINAGE SHALL BE SLOPED AT 1/4 -INCH PER LINEAL FOOT UNLESS OTHERWISE NOTED. 5 PROVIDE ALL NECESSARY DRAIN DOWN AND FILL OF EXISTING PLUMBING SYSTEMS (WATER & GAS) AS REQUIRED. PERFORM WORK TO NOT SHUTDOWN PLUMBING SYSTEMS FOR OCCUPIED AREAS DURING NORMAL WORKING HOURS. COORDINATE WITH CONTRACTOR AND NORDSTROM. 6. PLUMBING INSTALLER TO MAKE FINAL CONNECTION TO ALL EQUIPMENT. COORDINATE WITH KITCHEN EQUIPMENT INSTALLER AS REQUIRED FOR COMPLETE. INSTALLATION. 7 REFER TO KITCHEN DRAWINGS FOR EXACT ROUGH -IN LOCATIONS, SIZES AND FURTHER INFORMATION. 8. PLUMBING INSTALLER TO PROVIDE INDIRECT WASTE PIPING, SHUT-OFF VALVES, BACKFLOW PREVENTERS, TRAPS,REGULATORS, STOPS, SUPPLIES, SUPPORTS AND ACCESSORIES REQUIRED FOR FULL OPERATIONAL INSTALLATION. 9. ALL PENETRATIONS OF PIPING THRU FLOORS, CEILING, OR WALLS SHALL BE FIRE CAULKED AND SEALED WATER TIGHT. ALL SHUT-OFF VALVES. TO BE LOCATED WITHIN 12" FROM ACCESSIBLE CEILING TILE. IF NO CEILING LOCATE 10'-0" AFF. --2" rV UP —(E) 2-'I12" GAS UP ,..,..,(E). 1-1/4" CW SUPPLY UP TO WATER HEATER. y -_(E) 1-1/4" HV ( 140 °F) UP FROM WATER HEATER _ 314" HWR UP (E) 3 WATER FILTERS FOR ICE MACHIN wan 1 eff— Wal —Sher abinet Lift ruck n Wali. Sheff- Compac Walk -In. Freezer 1-1/2" -3" GW Walk -In Cooler Workble Slicer 9— V G --- -D4-� 0fi 2"G 18 WalF She f Worktable 4" GW 1` Filler1 4" GWRac Micro Piave. 2-1 /2" V- E) 4" W TO BUILDING' S REASE INTER( EPTOR-- P -11® 1-1/2"VDN Salad Table Hot Food Table Worktable Wall Shelf Wal She f CAFE REMODEL FLOOR PLAN - PLUMBING SCALE: 1/4"=1'-0 REVIEWED FOR :CODE COMPLIANCE 4=` APPROVED IJUL 9 9 2013 City of Tukwila BUILDING DIVISION PLUMBING DEMO NOTES: Gek) CAP EXISTING WATER SUPPLY TO COFFEE BREWER.. FIELD VERIFY. TEMPORARILY CAP HOT AND COLD WATER SUPPLIES FOR EXISTING KETTLE FILLER FAUCET. HELD VERIFY. REMOVE ALL EXISTING GAS PIPING FOR KITCHEN GAS EQUIPMENT. FIELD VERIFY. RECE PG 13--- 102, CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER Issued/Revised KITCHEN EQUIPMENT SCHEDULE PLUMBING SCHEDULE WATER WASTE GAS 0 QTY DESCRIPTION SUPPLIER HOT COLD OPEN DIR. CON. ` - MBTU REMARKS 2 GAS.PIZZA OVEN STACKED PRD - - _ _ . 3/4"40 _ NOTE P1 80 MBTU TOTAL, 2 -CONN. REQ'D, SEE 3- (I)1OWNER EXISTING GAS SIX BURNER RANGE - - - - 1-1�4" , 225 5PRD 1 24" GAS BROILER ' _ _ -1 - " 80 SEE NOTE P2 9PRD 1 RELOCATED KETTLE &STAND _ _ 1-1/2"— — — -DRAIN TO FLOOR SINK 10 1 KETTLE FILLER FAUCET PRD 1/2" 1/2" 11 Q 2 GAS CONY. OVENS - STACKED PRD - - -NOTE - 1 60 9 20 MBTU TOTAL,SEE O P3 (1) 1 _ HAND SINK &FAUCET REMOVE &REPLACE PRD112 1/2- 1-1/2 151 RELOCATED COFFEE BREWER OWNER 1/4" 16 1 THREE. COMP. SINK & FAUCE.T PRD 1/2/2 1/ 3 - - PLUMBING P1. P2. P3. PLUMBER FW PLUMBER PLUMBER PLUMBER BROILE.R FACTORY PLUMBER NOTES: L T SHALL INSTALL ALL EQUIPMENT PER LOCAL JURISDICTION. = FILTERED WATER U TO CONNECT PRD SUPPLIED 3/4"FLEX HOSES TO EACH OVEN K. ..._ SHUT SUPPLY. TO PROVIDE INDIVIDUAL OFF VALVES TO EACH GAS SUP TO CONNECT 1" REGULATOR AND 1" X 48" FLEX HOSE (PROVIDED BY PRD). WILL NOT BE COMMON MANIFOLD TO EXISTING RANGE. PROVIDES LOOSE MANIFOLD PIPING TO INTERCONNECT OVEN. GAS SUPPLIES. TO INSTALL PIPING AND ATTACH PRD SUPPLIED GAS FLEX HOSE. 505 MBTU TOTAL NEW & EXISTING) PLUMBING KEY NOTES: 0 1 2" GAS DOWN TO FLOOR BELOW; PROVIDE CORE DRILL AND SEAL PENETRATION WITH FIRE. RATED. SEALANT. CONNECT TO EXISTING 2" GAS STUB. SEE GAS RISER DIAGRAM FOR CONTINUATION. FIELD VERIFY. 2 PROVIDE 2" GAS MANIFOLD IN EXISTING WALL FOR. NEW AND EXISTING GAS EQUIPMENT. PROVIDE GAS SHUTOFF TO EACH EQUIPMENT. REFER TO EQUIPMENT SCHEDULE FOR CONNECTIONS. REFER TO KITCHEN DRAWINGS FOR OPENING UP OF WALL. 0 3 EXISTING 6 -BURNER RANGE TO REMAIN; PROVIDE NEW GAS SUPPLY. FIELD VERIFY. 0 4 RELOCATED KETTLE AND STAND. MODIFY AND EXTEND 1/2" CW AND 1/2r, HW TO NEW LOCATION FROM ITS EXISTING CONNECTIONS. PROVIDE PIPE INSULATION. FIELD VERIFY. 0 5 ROUTE 1-1/2" KETTLE DRAIN TO EXISTING FLOOR SINK. FIELD VERIFY. NEW SINK AND FAUCET. CONNECT 1/2" CW, 1/2" HW AND 1-1/2" WTO EXISTING. PROVIDE NEW TRAP, SUPPLIES AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 0 7 EXISTING HAND SINK, PROVIDE NEW TRAP, SUPPLIES, DRAIN PIPE INSULATION AND THERMOSTATIC MIXING VALVE (PER DETAIL 2/P1.1). SET HOT WATER TEMPERATURE TO 110 °F. MODIFY EXISTING PIPING AND ROUGH -IN AS REQUIRED. 0 RELOCATED COFFEE BREWER. PROVIDE 1/2" FILTERED WATER WITH SHUTOFF VALVE. PROVIDE PIPE INSULATION. F D VERIFY. 1/2"HW SUPPLY 1/2"CW AND TO THREE -COMPARTMENT SINK. PROVIDE PIPE INSULATION FOR HOT AND COLD WATER. 0 10 PROVIDE TRAP PRIMER WITH SHUTOFF TO SERVE FLOOR DRAIN. INSTALL BELOW THREE -COMPARTMENT SINK IN ACCESSIBLE LOCATION. 0 11 NEW FLOOR DRAIN. PROVIDE WITH TRAP PRIMER. 0 12 CONNECT 2" VENT TO EXISTING 2-1/2" VENT PIPING. FIELD VERIFY. o 13 CONNECT 3"WASTE TO EXISTING 4"WASTEVERIFY ROUTING. PIPING. FIELD E 0 14 GREASE WASTE PIPING AND VENT WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL 0 15 MODIFY AND CONNECT 1/2" FW FROM EXISTING WATER FILTERS. FIELD VERIFY. 0 16 GAS SHUTOFF VALVE AND ANSUL VALVE. COORDINATE EXACT LOCATION WITH KITCHEN CON ULTANT( -APPROX. 9"-12" BELOW CEILING). 0 17 CONNECT 2" GAS PIPING TO EXISTING 2" STUB LOCATED UNDER FLOOR. FIELD VERIFY. 0 18 GAS PIPING WHERE SHOWN LOCATED UNDER FLOOR. TYPICAL PLUMBING GENERAL NOTES: 1 COMPLY WITH ALL APPLICABLE CODES, STANDARDS AND ORDINANCES, INCLUDING THE UNIFORM PLUMBING. CODE (UPC) LATEST EDITION. 2. ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES AND EXISTING CONDITIONS. PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER OPERATION, SERVICING OF EQUIPMENT AND THE LOCAL CODE REQUIREMENTS. 3. FIELD VERIFY ALL EXISTING PLUMBING PIPING POINT OF CONNECTIONS PRIOR TO BEGINNING WORK. PROVIDE NECESSARY OFFSETS AND/OR REROUTES TO AVOID EXISTING CONDITIONS. 4. ALL DRAINAGE SHALL BE SLOPED AT 1/4 -INCH PER LINEAL FOOT UNLESS OTHERWISE NOTED. 5 PROVIDE ALL NECESSARY DRAIN DOWN AND FILL OF EXISTING PLUMBING SYSTEMS (WATER & GAS) AS REQUIRED. PERFORM WORK TO NOT SHUTDOWN PLUMBING SYSTEMS FOR OCCUPIED AREAS DURING NORMAL WORKING HOURS. COORDINATE WITH CONTRACTOR AND NORDSTROM. 6. PLUMBING INSTALLER TO MAKE FINAL CONNECTION TO ALL EQUIPMENT. COORDINATE WITH KITCHEN EQUIPMENT INSTALLER AS REQUIRED FOR COMPLETE. INSTALLATION. 7 REFER TO KITCHEN DRAWINGS FOR EXACT ROUGH -IN LOCATIONS, SIZES AND FURTHER INFORMATION. 8. PLUMBING INSTALLER TO PROVIDE INDIRECT WASTE PIPING, SHUT-OFF VALVES, BACKFLOW PREVENTERS, TRAPS,REGULATORS, STOPS, SUPPLIES, SUPPORTS AND ACCESSORIES REQUIRED FOR FULL OPERATIONAL INSTALLATION. 9. ALL PENETRATIONS OF PIPING THRU FLOORS, CEILING, OR WALLS SHALL BE FIRE CAULKED AND SEALED WATER TIGHT. ALL SHUT-OFF VALVES. TO BE LOCATED WITHIN 12" FROM ACCESSIBLE CEILING TILE. IF NO CEILING LOCATE 10'-0" AFF. --2" rV UP —(E) 2-'I12" GAS UP ,..,..,(E). 1-1/4" CW SUPPLY UP TO WATER HEATER. y -_(E) 1-1/4" HV ( 140 °F) UP FROM WATER HEATER _ 314" HWR UP (E) 3 WATER FILTERS FOR ICE MACHIN wan 1 eff— Wal —Sher abinet Lift ruck n Wali. Sheff- Compac Walk -In. Freezer 1-1/2" -3" GW Walk -In Cooler Workble Slicer 9— V G --- -D4-� 0fi 2"G 18 WalF She f Worktable 4" GW 1` Filler1 4" GWRac Micro Piave. 2-1 /2" V- E) 4" W TO BUILDING' S REASE INTER( EPTOR-- P -11® 1-1/2"VDN Salad Table Hot Food Table Worktable Wall Shelf Wal She f CAFE REMODEL FLOOR PLAN - PLUMBING SCALE: 1/4"=1'-0 REVIEWED FOR :CODE COMPLIANCE 4=` APPROVED IJUL 9 9 2013 City of Tukwila BUILDING DIVISION PLUMBING DEMO NOTES: Gek) CAP EXISTING WATER SUPPLY TO COFFEE BREWER.. FIELD VERIFY. TEMPORARILY CAP HOT AND COLD WATER SUPPLIES FOR EXISTING KETTLE FILLER FAUCET. HELD VERIFY. REMOVE ALL EXISTING GAS PIPING FOR KITCHEN GAS EQUIPMENT. FIELD VERIFY. RECE PG 13--- 102, CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER Issued/Revised Date Permit 06-18-13 "-1 . ost O w_cvtyo .04s e,0 a N W L.0 N Lo 6580124 Z ��Q�� RI N W 2 c(A) f HCEN FE RE NTER VILA, I 8 Y 11 9 1z Walk -In Cooler Sinkp Compactor _ i=i • • 1 Soil Dishtable Slant Rack H- JI Disposer X Dishwasher Clean Dishtable II I it I WW1_ _II_ Shelf n Existing vinylrock ceiling tiles, Quarry Tile & Cove Base Flooring, and FRP on walls to remain in kitchen Coffee LWall onen Microwave \ Kettle \ • • • • • • Range \\ • • 24" grdilje on worktable\ \ \/ \ ••\ • \\ Worktable Slicer { T \ / Worktable Mixer Hand Sink Worktable POS POS POS pGi3fOZ REVIEWED FOR CODE COMPLIANCE APPROVED IJUL 9 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER SCALE: 1/4" = BOy itt ter0Reta Aemodal 8010 EXISTING CAFE FLOOR PLAN Ex1.0 '1' I'ESJGN # C-3 )27 t22 V Date 05-14-13 Seale 1/4" = 1'-0" Drawn. G. Ahrens EXISTING CAFE FLOOR PLAN Ex1.0 (P> (3� 8 9 1z Walk -In Freezer • Soil Dishtable Dishwasher • • • • • • Worktable Mixer \� / Hand \ Sink Pass Window Sandwich Table • \ Wall Shelf Toasters • •• • Worktable • POS POS KQUIPMEXT SCHEDULE NO QTY DESCRIPTION SUPPLIER 1 1 STAINLESS STEEL WORKTABLE PRD 2 1 S/S LEFT HOOD ENCLOSURE PANEL PRD 3 2 GAS PIZZA OVENS - STACKED PRD 4 1 EXISTING GAS SIX BURNER RANGE OWNER 5 1 24" GAS BROILER PRD 6 1 EXISTING EXHAUST HOOD OWNER 7 1 EXISTING WORKTABLE OWNER 8 1 EXHAUST HOOD - NEW PSF 9 1 RELOCATED KETTLE & STAND OWNER 10 1 KETTLE FILLER FAUCET PRD 11 2 GAS CONV. OVENS - STACKED PRD 12 1 ADJUSTMENT OF ANSUL SYSTEM PRD 13 1 36" SINGLE S/S HIGH SHELF PRD 14 1 HAND SINK & FAUCET - REMOVE & REPLACE PRD 15 1 RELOCATED COFFEE BREWER OWNER 16 1 THREE COMP. SINK & FAUCET PRD 17 SPARE REVIEWED FOR CODE COMPLIANCE APPROVED IJUL 2 9 2013 City of Tukwila BUILDING DIVISION PG SCALE: 1/4" = 1'-0" RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER hoRsitdrattaimodal CAFE REMODEL FLOOR PLAN RK1.0 8 J BOX + 48", # (2) DUPLEXES + 24" & + 48", # 11 10 Y Y Walk -In Cooler Prep Worktable Slicer Sink 0 C 3 Soil Dishtable i Compacdor ( c Worktable • • • • Mixer Disposer Dishwasher Rock I X _____________________ _________________ir______________________________________________________________________________ 1 u Wall Shelf • •` / r / Hand Sink Soda \• • POS POS RE -USE EXISTING DUPLEX + 48", # 15 EQUIP-VIE\T SCHEDULE ELECTRICAL SCHEDULE NO QTY DESCRIPTION SUPPLIER VT PH AMP KW HP REMARKS 1 1 STAINLESS STEEL WORKTABLE PRD - - - - - 2 1 S/S LEFT HOOD ENCLOSURE PANEL PRD - - - - - 3 2 GAS PIZZA OVENS - STACKED PRD - - - - 4 1 EXISTING GAS SIX BURNER RANGE OWNER 5 1 24" GAS BROILER PRD - - - - - 6 1 EXISTING EXHAUST HOOD OWNER - - - - - 7 1 EXISTING WORKTABLE OWNER - - - - - 8 1 EXHAUST HOOD - NEW PSF - - - - - 9 1 RELOCATED KETTLE & STAND OWNER 208 3 - 10.8 HW, SHUNT BREAKER REQ'D - 10 1 KETTLE FILLER FAUCET PRD - - - - - 11 2 GAS CONV. OVENS - STACKED PRD 120 1 6.0 - 1/3 5 - 20R, GFCI, SHUNT BREAKER REQ'D 12 1 ADJUSTMENT OF ANSUL SYSTEM PRD - - - - - 13 1 36" SINGLE S/S HIGH SHELF PRD - - - - - 14 1 HAND SINK & FAUCET - REMOVE & REPLACE PRD - - - - - 15 1 RELOCATED COFFEE BREWER OWNER CONFIRM WITH OWNER 16 1 THREE COMP. SINK & FAUCET PRD - - - - - 17 SPARE REVIEWED FOR CODE COMPLIANCE APPROVED IJUL 2 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER P6 ( o SCALE: 1/4" = 1'-0" EDI strogyametiel CAFE REMODEL ELECTRICAL PLAN RK2,Q CA> ( 1/2" H & CW + 54", * 10, DRAIN TO EXISTING FLOOR SINK ON OTHER SIDE OF WALL RE -USE EXISTING FLOOR SINK, REMOVE EXISTING KETTLE FILL FAUCET (2) 3/4" GAS CONNECTION + 26" & + 52", " GAS CONNECT + 48", * 11 1" GAS CONNECTION + 12", * 5 8 9 Walk -In Freezer Walk -In Cooler Prep Sink m 0' 0o In — Soil Dishtable Disposer Wall — - -Shel 1 NEW FLOOR] DRAIN 1 EXISTING FLOOR SINK 1 1 (2) 1/2" 11 & CW + 16", (3) 1 1/2" fOTASTES MANIFOLDED TOGETHER + 14", DRAIN DIRECT TO 3" WAS'I?E LINE IN WALL, * 16 i 1 -1------ 1 \ • • 1 RE -USE EXISTING 1/2" H & CW + 22", 1-1/2" WASTE + 20", 0 14 RE -USE EXISTING 3/8" FCW + 46", # 15 POS POS EQUIPME\ T SCHEDUL H i PL [ MBIN G SCHEDULE WATER WASTE GAS NO QTY DESCRIPTION SUPPLIER HOT COLD OPEN DIR. CON. MBTU REMARKS 1 1 STAINLESS STEEL WORKTABLE PRD — — — — — — Scale 1/4" = 1'-0" 2 1 S/S LEFT HOOD ENCLOSURE PANEL PRD — — — — — — 3 2 GAS PIZZA OVENS - STACKED PRD — — — — 3/4" 40 80 TOTAL, TWO CONN, REQ`D, SEE NOTE * P1 4 1 EXISTING GAS SIX BURNER RANGE OWNER 5 1 24" GAS BROILER PRD — — — — 1" 80 SEE NOTE * P2 6 1 EXISTING EXHAUST HOOD OWNER — — — — — — 7 1 EXISTING WORKTABLE OWNER — — — — — — 8 1 EXHAUST HOOD - NEW PSF — — — — — — 9 1 RELOCATED KETTLE & STAND OWNER — — 1-1/2" — — — DRAIN TO FLOOR SINK 10 1 KETTLE FILLER FAUCET PRD 1/2" 1/2" — — — — 11 2 GAS CONV. OVENS - STACKED PRD — — — — 1" 60 120 MBTU TOTAL, SEE NOTE * P3 12 1 ADJUSTMENT OF ANSUL SYSTEM PRD — — — — — — 13 1 36" SINGLE S/S HIGH SHELF PRD — — — — — — 14 1 HAND SINK & FAUCET - REMOVE & REPLACE PRD 1/2" 1/2" — 1-1/2" — — 15 1 RELOCATED COFFEE BREWER OWNER CONFIRM WITH OWNER 16 1 THREE COMP. SINK & FAUCET PRD 1/2" 1/2" 3" — — — 17 SPARE PLUMBING NOTES: FCW = FILTERED COLD WATER P1. PLUMBER TO CONNECT PRD SUPPLIED 3/4" FLEX HOSES TO EACH OVEN DECK. PLUMBER TO PROVIDE AND INSTALL INDIVIDUAL SHUT OFF VALVES TO EACH GAS SUPPLY. P2. PLUMBER TO CONNECT 1" REGULATOR AND 1" x 48" FLEX HOSE (PROVIDED BY PRD). BROILER WILL NOT BE COMMON MANIFOLDED TO EXISTING RANGE. P3. FACTORY PROVIDES LOOSE MANIFOLD PIPING TO INTERCONNECT OVEN GAS SUPPLIES. PLUMBER TO INSTALL PIPING AND ATTACH PRD SUPPLIED GAS FLEX HOSE. fEVIEWED FOR tifJF E COMPLIANCE APPROVED IJUL 29 2013 City of Tukwila BUILDING DIVISION SCALE: 1/4" = 1/-0" RECEIVED CITY OF TUKWILA JUL 1 6 2013 PERMIT CENTER oral romi model BDIO ■ Revision: By• STAURANT] th Avenue N.W., * C- iquah, WA 98027 ane: 425-392-7422 \T1 Date 05-14-13 Scale 1/4" = 1'-0" Drawn G. Ahrens CAFE REMODEL PLUMBING PLAN RK3.0