HomeMy WebLinkAboutPermit PG13-104 - J CREW - ALTERATIONJ CREW
535 SOUTHCENTER MALL
PG13-104
Parcel No.:
Address:
City ogukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
9202470010
S35 SOUTHCENTER MALL TUKW
Project Name: J CREW
Permit Number:
Issue Date:
Permit Expires On:
PG 13-104
09/18/2013
03/17/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
Contractor
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD CA 92013
GARY PALMER
PO BOX 23534 , EUGENE OR 97492
NOT PROVIDED
GS MECHANICAL LLC
PO BOX 1917 , RENTON WA 98057
License No: GSMECML928RK
Phone: 541-603-4191
Phone: 206-372-0332
Expiration Date: 12/12/2014
DESCRIPTION OF WORK:
INSTALLATION INTO OF NEW COLD WATER LINE, SANITARY WASTE AND VENT PIPING WITH
NEW RESTROOM PLUMBING FIXTURES. ALSO INSTALLING NEW WATER HEATER AND WATER
DISPENSER.
Value of Plumbing/Gas Piping:
Fees Collected:
Electrical Service Provided by:
$21,500.00
$436.88
Uniform Plumbing Code Edition: 2009
International Fuel Gas Code Edition: 2009
Permit Center Authorized Signature: - Date:
I hereby certify that I have read and examine this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions
on the back of this permit.
Date: 7—/6
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
eine• In
Dl11'1_1 nd
Printati• nQ_1P-9n11
PERMIT CONDITIONS
Permit No. PG 13-104
1: ***PLUMBING AND GAS PIPING***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
uan
oneo •IIIA D...4 '1• AC1 l Al7
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Plumbing/Gas Permit No. V 6 1 - (0 Li
X13—®$S
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
Tenant Name:
535 Southcenter Mall
J Crew
King Co Assessor's Tax No.:
Suite Number: 676 Floor: Ground
PROPERTY OWNER
Name: Gary Palmer, Property Service
Name: Westfield
City: Eugene State: OR Zip: 97492
Address: 11601 Wiltshire Blvd
Email: psconsultants@sbcglobal.net
City: Los Angeles State: CA
Zip: 90025
CONTACT PERSON — person receiving all project
communication
Name: Gary Palmer, Property Service
Address: PO Box 23534
City: Eugene State: OR Zip: 97492
Phone: (514) 603-4191 Fax:
Email: psconsultants@sbcglobal.net
New Tenant: 0 Yes ❑ .. No
PLUMBING CONTRACTOR INFORMATION
Company Name: TBD p' 5 o� /tin/,' e..., G
Address: i /9/ 7
f
City: ti) To� State: i,-/) Zip: f
Phone: i 06, ` 3 7i 03J
Contr Reg No.: liit/ . -•mit. �t�'-. Date:
j f2 -`I x -'%y
Tukwila Business License No.: /.,S ,s . _ 513 a 5,3
( to - Li-)
Valuation of Project (contractor's bid price): $ 21,500
Scope of Work (please provide detailed information):
Installation into of new cold water line, sanitary waste and vent piping with new restroom plumbing fixtures. Also installing new
water heater and water dispenser
Building Use (per Int'I Building Code): IIB
Occupancy (per Int'I Building Code):
Utility Purveyor: Water: Tukwila
M
H:"ApplicalionslFotms-Applications On Line12011 Applicat
Revisal: August 2011
bh
\Plunbing Penni Applicmion Revised 8-9-11.docz
Sewer Tukwila
Page 1of2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
2
Shower, single head trap
1
Sinks
1
Rain water system -- per
drain (inside building)
1
Grease interceptor for
commercial kitchen (>750
gallon capacity)
6
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
2
Lavatory
1
Urinal
1
Water heater and/or vent
1
Repair or alteration of
water piping and/or water
treatment equipment
6
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
1
Wash fountain
Water closet
1
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
6
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
1
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AG
Signature:
Print Name: Gary Palmer
►- Date: 7/ 2'.)'-/i6i
Mailing Address: PO Box 23534
H:1Appli atiorsTorns-Applicatio s On L ne12011 Applieations\Plumbiog Permit Application Revised S-9-11.docx
Revised: August 2011
bh
Day Telephone:
Eugene
city
6 o 3. (er q l
OR 97492
State Zip
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
Parcel No.: 9202470010 Permit Number: PG13-104
Address: 535 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 07/22/2013
Applicant: J CREW Issue Date:
Receipt No.: R13-02667
Initials:
User ID:
TLS
1670
Payment Amount: $349.50
Payment Date: 09/18/2013 01:27 PM
Balance: $0.00
Payee: GREG SHALLING GS MECHANICAL LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 518152
ACCOUNT ITEM LIST:
Description
349.50
Account Code Current Pmts
PLUMBING - NONRES
000.322.103.00.00 349.50
Total: $349.50
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
Parcel No.: 9202470010 Permit Number: PG13-104
Address: 535 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 07/22/2013
Applicant: J CREW Issue Date:
Receipt No.: R13-02184
Initials: WER
User ID: 1655
Payment Amount: $87.38
Payment Date: 07/22/2013 04:32 PM
Balance: $349.50
Payee: GARY R PALMER
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 00966G
ACCOUNT ITEM LIST:
Description
87.38
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 87.38
Total: $87.38
rine• P r int-nR
Printed: 07-22-2013
INSPECTION RECORD
Retain a copy with permit
INSPEC-TION NO. PERMIT NO. `\
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:
C'r )
Type of Inspection:
1 INIAL. ,
Address:
(_St S. C.
Mvl A i l
Date Called:
_
Special Instructions:
Date W"anted:(a.m:
ICV - - I - I -7D
p:m:
Requester:
Phone No:
5,1 I -gob -G33
NApprove!`per applicable codes.
Corrections required prior to approval.
COMMENTS:
61-41
Insp or:
Date:
11—
R NSPECTION FE REQUIRED. Prior to next inspection. fee must be
d at 6300 Southcenter Blvd.. Suite 1 O. Call to schedule reinspection.
•
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
P6 i3 40
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36701
Permit Inspection Request Line (206) 431-2451
Project •
J V Q "`�
Type( f Inspection:
rc 9 L16� U-" J.__�
Address;,, 3 s sc.Aft mi../
Date Called:
Special Instructions: • /
Date Wanted:
Ci -2._:;5-
1...- ! �JP.m.
.--;+
Requester:
Phone No:
Approved per applicable codes. D Corrections required prior to approval.
COMMENTS:
c—rc
6\l'ef
I1 / Les J r_. c-)
j t1% 11 -T-As p -e -c '"- I e
Inspect(
Dat
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INS'ECTION NO. PERMIT NO. /,
CITY OF TUKWILA BUILDING DIVISION /y
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Phi; -I0''(
Pro'ec
/- c Vl�
Type of Inspection:
G r v J h.f
/�.
Ulf d i v�
Addre s:
53S Sc -
�.
Date Called:
Special Instructions:
Date Wanted
It 7. 3
*
�p.m.
�a.m '
Requester:
-Phone-No: .
Approved per applicable codes. E Corrections required prior to approval.
COMMENTS:
Insp
or:
Datgr� Z �� 3
n REINSPECTION FEE REQUIRErior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Callao schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
s-164
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100. Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Proj4ct:
,-..) C cz_.,kA ;
Type of Inspection:
R int9 li -; i.) `PILANI 6
Address:
‘53S S C
ni gei , 1
Date Called:
Special Instruttions:
Date Wanted:
a.m.
(02—W.",;
Requester:
Phone No: -
ElApproved per applicable codes. Corrections required prior to approval. -
COMMENTS:
At.ff, c ay 63--x)-/-Ao-rd e
Ins' -ctr:
Date: •
CAA)CA—A--- I — 20—
RElpSPECTION FEE REQ IRED. Prior to n!ext inspection, fee must be
aiid at 6300 Southcenter :vd., Suite 100. Call to schedule reinspection.
PERMIT COORD COPY •
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG13-104 DATE: 07-22-13
PROJECT NAME: J CREW
SITE ADDRESS: 535 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTME� S: .21
Building' Division
4Ac W* Structural
Fire Prevention
Planning Division
Permit Coordinator
N
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
DUE DATE: 07-25-13
Not Applicable
n
Comments:
Permit Center Use .Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route r5Z1 Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
n
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 08-22-13
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeople Prier Friendly Page
i
General/Specialty Contractor
A business registered as a construction contractor with LIiI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
Parent Company
GS MECHANICAL LLC
2063720332
Po Box 1917
Renton
WA
98057
King
Limited Liability Company
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602564160
Active
GSMECML928RK
Construction Contractor
12/12/2008
12/12/2014
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
SMALLING, GREG
Partner/Member
12/12/2008
Amount
SMALLING, GARY
Partner/Member
12/12/2008
BKS53764777
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
SI1307
12/09/2008
Until Cancelled
$12,000.00
12/12/2008
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Ohio Security
Ins Co
BKS53764777
02/27/2012.
02/27/2014
$1,000,000.0002/26/2013
2
Ohio Cas Ins Co
BR053764777
02/27/2009
02/27/2012
$1,000,000.0002/24/2011
1
CBIC
C11S11307
12/09/2008
12/09/2009
03/13/2009
$1,000,000.0012/12/2008
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httns://fortress.wa.gov/lni/bbin/Print.asnx 09/18/2013
GATE/BALL
VALVE BY P.
(•)
3/4
W ►�
ET -1 AMTROL
THERMAL
EXPANSION
ABSORBER �-'��
1' T & P REUEF
VALVE BY P.C.
1" RUN FULL SIZE
TO MOP SINK.
DRAIN VALVE BY P.C.
SHELF ABOVE MOP SINK,
SHELF & BRACKETS BY
GENERAL CONTRACTOR:
1'
ACUUM BREAKER
BY P.C.
-HANGERS INSTALLED
EACH SIDE OF EXP.
TANK FOR SUPPORT
c�-�iTQ—HW
3/415/
tl
1' TO MOP SINK
WATER HEATER SCHEMATIC
NTS
OWER SUPPLY
BY E.C.
JUNC11ON BOX
(TYP.)
INSULAALL PIPING
IN ACCOfDANCE WITH
SPECIFICATIONS.
UNION B
(TYP.)
P.C.
WATER HATER SEE
PLUMBINGFIXTURE
SCHEDULE FOR
ADDITION/ L INFO.
2" WIDE, a0 GA.
SHEET ME(UAL BAND,
SECURE T). WALL FOR
SEISMIC BlACING
WHERE i=QUIRED BY
CODE. (B P.C.)
-GALV. DRII
BY P.C.
3/4" TO MOP
SINK
PIPING MATERIAL SPECIFICATIONS
SANITARY SEWER AND VENT PIPING
* PIPE NO—HUB CAST IRON PER CISP 301
* FITTINGS: NO—HUB CAST IRON PER ASTM
C-564
* JOINTS: NO—HUB CAST IRON
T PIPE OPTION
* PIPE: COPPER DWV
* FITTINGS: COPPER DWV
DOMESTIC WATER
* PIPE: COPPER TYPE "L"
* FITTINGS: WROUGHT COPPER
* JOINTS: LEAD FREE SOLDER
* VALVES: BALL TYPE, NIBCO #S-580 OR EQUAL
CONDENSATE PIPING SYSTEM
* PIPE: COPPER TYPE "M"
* FITTINGS: WROUGHT COPPER
* JOINTS: LEAD FREE SOLDER
ROOF AND OVERFLOW STORM DRAINAGE SYSTEM
* INTERIOR UNDERGROUND: CAST IRON SOIL PIPE
AND FITTINGS, BELL & SPIGOT HUB TYPE,
SERVICE EIGHT, ASTM A74, HUBLESS CI PIPE
WITH NEOPRENE RUBBER COMPRESSION
GASKETS, ASTM C564.
* INTERIOR UNDERGROUND: BELL & SPIGOT HUB
TYPE CAST IRON SOIL PIPE AND FITTINGS,
CISPI 301, WITH HUB TYPE COUPLINGS WITH
STAINLESS STEEL CLAMPS, MISSION TYPE
COUPLING BAND & CLAMP, HUSKY SERIES
4000, CLAMP — ALL HUB TYPE COUPUNG,
CISPI 310, OR EQUAL
NATURAL GAS
* PIPE: ASTM A53, TYPE F, STANDARD WEIGHT,
BLACK STEEL
* FITTINGS: ASTM A197/ANSI B16.3, CLASS 150,
BLACK MALLEABLE IRON, THREADED JOINTS.
* UNIONS: MALLEABLE IRON, CLASS 250
PAN
REFER TO SHEET M-300 FOR PLUMBING SPECIFICATIONS.
1SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
t3Plumbing
Gas Piping
City of Tukwila
ELUDING DIVISION
REVISIONS
No changes shall bemade to the scope
of work without prior approval of
Tukwila Building Division.
NOM: Revisions will require a new plan submittal
and may include additional plan review flees.
V
0
• OB -1
FOR BOTTLELESS COOLER
1
PLUMBING PLAN
1 /4"=1'-0"
PLUMBING FIXTURE SCHEDULE BASIS OF DESIGN MANUFACTURER LISTED BELOW:
EQUIVALENTS ACCEPTED AFTER REVIEW
FIXTURE
NO.
FIXTURE TYPE
WASTE
VENT
CW
HW
REMARKS
SK -1
"
2 "FAUCET
1 2
ELKAY LRADQ2222 18 GAUGE TYPE 304 STAINLESS STEEL, SELF—RIMMING SINK WITH HOLE SPECIFICA I I'► •
MODEL 2302 GOOSENECK FAUCET AND 0.5 GP,: : :• �' - ' i'• •1 02 CONFORMS TO ADA
CHICAGO -
SINK
fa
GARBAGE DISPOSAL__-"
—
—
—
IN—SINK—ERATOR BADGER 5XP 3/4 HP MOTOR
.011
ELECTRIC WATER HEATER
—
—
3/4"
3/4"
A.O. SMITH ELECTRIC WATER HEATER MODEL DEL -06, 1.5 KW, 6 GALLON. MOUNT ON SHELF ABOVE MOP SINK. PROVIDE WITH 4"
DRAIN PAN AND AMTROL EXPANSION TANK MODEL THERM—X—TROL—ST-5—C. SEE DIVISION 16 DRAWINGS FOR VOLTAGE AND PHASE.
EQUAL BY RHEEM OR RUUD
LAV,
UNDRECOUNTER MOUNTED LAVATORY
2"
1-1/2"
1/2"
1/2"
KOHLER MODEL K-2030 GREENWICH — WHITE. UNDERMOUNT IN CORIAN COUNTER COLO NOCTURN. INSULATE PIPING BELOW COUNTER
WITH "LAV—GUARD" FOR ADA COMPLIANCE. PROVIDE WITH TRITON FAUCETS MODEL K-7443 IN POLISHED CHROME WITH SECURE
POP—UP DRAIN KNOB. PROVIDE WITH POUSHED CHROME DRAIN AND STRAINER.
IE
TRAP PRIMER
—
—
1/2"
—
JAY R. SMITH, PRIME EZE WATER SAVER TRAP PRIMER MODEL NO. 2698
WC_1
WATER CLOSET
4`
2"
2"
1/2"
—
KOHLER TOILET MODEL K-3529 DEVONSHIRE, WHITE, COMFORT HEIGHT, 1.6 GPF TANK TYPE, ADA COMPUANT WITH THE FOLLOWING:
K-7637 ANGLE STOP, K -9167—L OR K -9167—R TRIP LEVER TO BE ON THE OPEN SIDE OF TANK
SEAT HINGE ,TRIP LEVER, ANGLE STOP POUSHED CHROME
K-4731—SC SEAT — BLACK
I
MOP SINK
M
3
N
1-1/2
N
3/4
N
3/4
FIAT MSB -2424 MOLDED STONE MOP BASIN WITH VINYL BUMPER—GUARD; FURNISH WITH AMERICAN STANDARD 8344.111 FAUCET
WITH INTEGRAL VACUUM BREAKER AND STOPS. PROVIDE MOP HANGER — SEE ARCH. DRAWINGS
ED.
FLOOR DRAIN
3"
1 1/2"
—
—
J.R. SMITH 2010—B STRAINER, 4" SQUARE, CHROME FINISH PROVIDE TRAP PRIMER, ZURN ZARB-1022 SANI—GUARD, ALL BRONZE BODY,
BODY WITH INTEGRAL VACUUM BREAKER, NON—LINING INTERNAL OPERATING ASSEMBLY WITH GASKET BRONZE COVER
Lg.
FLOOR CLEAN OUT
SIZE
—
—
—
JOSAM SERIES NO. 55000—Z WITH NICKALOY ROUND CAP.
WCO
WALL CLEANOUT
UNE
SIZE
—
—
—
WALL CLEAN OUT — CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT.
WALL ACCESS! PANEL — ZURN #ZANB-1460-9, 9" X 9" WALL ACCESS PANEL AND FRAME; SMOOTH NICKEL BRONZE SECURING LUGS.
ACCEPTABLE ALTERNATES, WADE OR SMITH.
MAYTHERMOSTATIC
MIXING VALVE
—
—
LI
SINE
SIZE
POINT OF USE. WATTS MODEL MMV—US—M1. SET FOR 110' F
ED -2
1
FUNNEL DRAIN
A r, •:i a ;� — 1 • " - "_ - — - •r. *'l • L :Y J.R. SMITH OR WADE. FOR AHU CONDENSATE DISPOSAL
—
—
2"
2
Q.
OUTLET BOX
—
—
1/2"
—
OUTLET BOX 10 WATER COOLER CONNECTIONS. OATEY OFFSET DRAIN #38791. PROVIDE WITH 1/2" CHECK VALVE.,
PROVIDE WITH 1/4 SHUT OFF VALVE. INSTALL OUTLET BOX AT 20" FROM FLOOR TO CENTER OF OUTLET BOX.
DF -1
DRINKING FOUNTAIN
2"
1-1/2"
1/2"
—
ELKAY EZSTL8C WALL—MOUNTED BARRIER FREE, (ADA COMPLIANT) DUAL LEVER FRONT AND SIDE PUSH ACTUATOR BARS, STAINLESS STEEL
BOWL, FLEXIBLE POLYESTER ELASTOMER SAFETY BUBBLE AND GALVANIZED STEEL FRONT AND SIDES, CHILLER WITH 80 GALLONS PER HOUR
CAPACITY, 507 DRINKER WATER AT 807 INLET TEMPERATURES 907 ROOM TEMPERATURE; TRIM MCGUIRE 2165CC COMPRESSION ANGLE STOP
VALVE WITH RISE ESCUTCHEON, MCGUIRE 8872CF 1-1/4" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P—TRAP AND WASTE ARM
WITH CLEANOUT PLUG AND ESCUTCHEON, AND SUITABLE CARRIER WITH STANCHIONS TO FLOOR.
1
I+
0
0
0
0
0
i
,1
1-1/2),
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 3 0 2013
City o T kwila
BUILDIN !VISION
3/4"
1/2"
TO FD
LAY
I '> .
1/2"
OB -1
I 3/4" v
I
f1/2"
li-e-1 /2"
I
iii_C=1.
(-1/2"
DF -1J
3/4"
[L LAV
RISER
NTS
PLUMBING CODED NOTES:
CONNECT NEW 4" SANITARY UNE INTO THE LANDLORD'S EXISTING SANITARY
SERVICE FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO
BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND
COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR
FINISH. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR
FURTHER INFORMATION. COORDINATE WITH LANDLORD AND TENANT
BELOW FOR BELOW FLOOR INSTALLATION.
CONNECT NEW 2" VENT UNE FROM TENANTS PLUMBING FIXTURES TO
LANDLORD PROVIDED VENT CONNECTION. FIELD VERIFY EXACT SIZE
AND LOCATION.
CONNECT NEW COLD WATER UNE INTO THE LANDLORD'S EXISTING
WATER UNE FIELD VERIFY LOCATION OF WATER UNE PRIOR TO
STARTING WORK. PROVIDE WITH WATER METER AND REMOTE READ
OUT. VERIFY METER TYPE AND LOCATION WITH LANDLORD'S ON SITE
FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC
COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER
DIAGRAM AND AS REQUIRED PER PDI WH 201. UNITS AS SUPPUED
BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO
ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING
SPECIFICATIONS FOR FURTHER INFORMATION.
FILE COPY
Permit No. V& /221-Q`i
Plan review approval Is to ernxs and omissions.
Approval of construction documents does not authorize
or ordnance. Receipt
BY
City Of
BUILDING DIVISION
DOMESTIC HOT WATER 12r= MhTAXI VU WD ILA
JUL 2013
PERMIT CENTER
FIELD VERIFY ALL CONDITIONS
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT
THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT
EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL
LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE
TO EXISTING CONDITIONS.
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR
OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND
CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL
COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY
TFIE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE
FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF
LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR
BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT
ACCORDANCE WITH GOVERNING CODES, THE PLANS AND
SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL
ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT
DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
T'G 13-- I 0
1r0
M -Engineering
750 Brooksedge Blvd.
Westerville, Ohio 43081
phone: 614.839.4639
fax: 614.839.2222
All rights reserved. No part of these drawings
or specifications may be copied, reproduced
or used in connection with any work, other
than the specific project for which they have
been prepared, without prior written
authorization from the Architect.
ENGINEER OF RECORD:
C REW
Southcenter Mall
.683.-Southcenter Mall
Space No. 676
Seattle, WA 98188
Level: Ground Floor
Project No. 1339
Project No. 13411114
NO.
DATE
ISSUE
07-17-13
Issue for Permit
07-17-13
Issue for Bid
07-17-13
Issue for LL & Client
Review
Plumbing Plan
P-100