Loading...
HomeMy WebLinkAboutPermit PG13-104 - J CREW - ALTERATIONJ CREW 535 SOUTHCENTER MALL PG13-104 Parcel No.: Address: City ogukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 9202470010 S35 SOUTHCENTER MALL TUKW Project Name: J CREW Permit Number: Issue Date: Permit Expires On: PG 13-104 09/18/2013 03/17/2014 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA 92013 GARY PALMER PO BOX 23534 , EUGENE OR 97492 NOT PROVIDED GS MECHANICAL LLC PO BOX 1917 , RENTON WA 98057 License No: GSMECML928RK Phone: 541-603-4191 Phone: 206-372-0332 Expiration Date: 12/12/2014 DESCRIPTION OF WORK: INSTALLATION INTO OF NEW COLD WATER LINE, SANITARY WASTE AND VENT PIPING WITH NEW RESTROOM PLUMBING FIXTURES. ALSO INSTALLING NEW WATER HEATER AND WATER DISPENSER. Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: $21,500.00 $436.88 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Permit Center Authorized Signature: - Date: I hereby certify that I have read and examine this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Date: 7—/6 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. eine• In Dl11'1_1 nd Printati• nQ_1P-9n11 PERMIT CONDITIONS Permit No. PG 13-104 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. uan oneo •IIIA D...4 '1• AC1 l Al7 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. V 6 1 - (0 Li X13—®$S Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 535 Southcenter Mall J Crew King Co Assessor's Tax No.: Suite Number: 676 Floor: Ground PROPERTY OWNER Name: Gary Palmer, Property Service Name: Westfield City: Eugene State: OR Zip: 97492 Address: 11601 Wiltshire Blvd Email: psconsultants@sbcglobal.net City: Los Angeles State: CA Zip: 90025 CONTACT PERSON — person receiving all project communication Name: Gary Palmer, Property Service Address: PO Box 23534 City: Eugene State: OR Zip: 97492 Phone: (514) 603-4191 Fax: Email: psconsultants@sbcglobal.net New Tenant: 0 Yes ❑ .. No PLUMBING CONTRACTOR INFORMATION Company Name: TBD p' 5 o� /tin/,' e..., G Address: i /9/ 7 f City: ti) To� State: i,-/) Zip: f Phone: i 06, ` 3 7i 03J Contr Reg No.: liit/ . -•mit. �t�'-. Date: j f2 -`I x -'%y Tukwila Business License No.: /.,S ,s . _ 513 a 5,3 ( to - Li-) Valuation of Project (contractor's bid price): $ 21,500 Scope of Work (please provide detailed information): Installation into of new cold water line, sanitary waste and vent piping with new restroom plumbing fixtures. Also installing new water heater and water dispenser Building Use (per Int'I Building Code): IIB Occupancy (per Int'I Building Code): Utility Purveyor: Water: Tukwila M H:"ApplicalionslFotms-Applications On Line12011 Applicat Revisal: August 2011 bh \Plunbing Penni Applicmion Revised 8-9-11.docz Sewer Tukwila Page 1of2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 2 Shower, single head trap 1 Sinks 1 Rain water system -- per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) 6 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 2 Lavatory 1 Urinal 1 Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment 6 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 1 Wash fountain Water closet 1 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 6 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 1 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AG Signature: Print Name: Gary Palmer ►- Date: 7/ 2'.)'-/i6i Mailing Address: PO Box 23534 H:1Appli atiorsTorns-Applicatio s On L ne12011 Applieations\Plumbiog Permit Application Revised S-9-11.docx Revised: August 2011 bh Day Telephone: Eugene city 6 o 3. (er q l OR 97492 State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG13-104 Address: 535 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/22/2013 Applicant: J CREW Issue Date: Receipt No.: R13-02667 Initials: User ID: TLS 1670 Payment Amount: $349.50 Payment Date: 09/18/2013 01:27 PM Balance: $0.00 Payee: GREG SHALLING GS MECHANICAL LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 518152 ACCOUNT ITEM LIST: Description 349.50 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 349.50 Total: $349.50 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: PG13-104 Address: 535 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/22/2013 Applicant: J CREW Issue Date: Receipt No.: R13-02184 Initials: WER User ID: 1655 Payment Amount: $87.38 Payment Date: 07/22/2013 04:32 PM Balance: $349.50 Payee: GARY R PALMER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 00966G ACCOUNT ITEM LIST: Description 87.38 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 87.38 Total: $87.38 rine• P r int-nR Printed: 07-22-2013 INSPECTION RECORD Retain a copy with permit INSPEC-TION NO. PERMIT NO. `\ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: C'r ) Type of Inspection: 1 INIAL. , Address: (_St S. C. Mvl A i l Date Called: _ Special Instructions: Date W"anted:(a.m: ICV - - I - I -7D p:m: Requester: Phone No: 5,1 I -gob -G33 NApprove!`per applicable codes. Corrections required prior to approval. COMMENTS: 61-41 Insp or: Date: 11— R NSPECTION FE REQUIRED. Prior to next inspection. fee must be d at 6300 Southcenter Blvd.. Suite 1 O. Call to schedule reinspection. • INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6 i3 40 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36701 Permit Inspection Request Line (206) 431-2451 Project • J V Q "`� Type( f Inspection: rc 9 L16� U-" J.__� Address;,, 3 s sc.Aft mi../ Date Called: Special Instructions: • / Date Wanted: Ci -2._:;5- 1...- ! �JP.m. .--;+ Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: c—rc 6\l'ef I1 / Les J r_. c-) j t1% 11 -T-As p -e -c '"- I e Inspect( Dat REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS'ECTION NO. PERMIT NO. /, CITY OF TUKWILA BUILDING DIVISION /y 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Phi; -I0''( Pro'ec /- c Vl� Type of Inspection: G r v J h.f /�. Ulf d i v� Addre s: 53S Sc - �. Date Called: Special Instructions: Date Wanted It 7. 3 * �p.m. �a.m ' Requester: -Phone-No: . Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Insp or: Datgr� Z �� 3 n REINSPECTION FEE REQUIRErior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Callao schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit s-164 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100. Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj4ct: ,-..) C cz_.,kA ; Type of Inspection: R int9 li -; i.) `PILANI 6 Address: ‘53S S C ni gei , 1 Date Called: Special Instruttions: Date Wanted: a.m. (02—W.",; Requester: Phone No: - ElApproved per applicable codes. Corrections required prior to approval. - COMMENTS: At.ff, c ay 63--x)-/-Ao-rd e Ins' -ctr: Date: • CAA)CA—A--- I — 20— RElpSPECTION FEE REQ IRED. Prior to n!ext inspection, fee must be aiid at 6300 Southcenter :vd., Suite 100. Call to schedule reinspection. PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-104 DATE: 07-22-13 PROJECT NAME: J CREW SITE ADDRESS: 535 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTME� S: .21 Building' Division 4Ac W* Structural Fire Prevention Planning Division Permit Coordinator N DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 07-25-13 Not Applicable n Comments: Permit Center Use .Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route r5Z1 Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-22-13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prier Friendly Page i General/Specialty Contractor A business registered as a construction contractor with LIiI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company GS MECHANICAL LLC 2063720332 Po Box 1917 Renton WA 98057 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602564160 Active GSMECML928RK Construction Contractor 12/12/2008 12/12/2014 General Unused Business Owner Information Name Role Effective Date Expiration Date SMALLING, GREG Partner/Member 12/12/2008 Amount SMALLING, GARY Partner/Member 12/12/2008 BKS53764777 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SI1307 12/09/2008 Until Cancelled $12,000.00 12/12/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Ohio Security Ins Co BKS53764777 02/27/2012. 02/27/2014 $1,000,000.0002/26/2013 2 Ohio Cas Ins Co BR053764777 02/27/2009 02/27/2012 $1,000,000.0002/24/2011 1 CBIC C11S11307 12/09/2008 12/09/2009 03/13/2009 $1,000,000.0012/12/2008 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.gov/lni/bbin/Print.asnx 09/18/2013 GATE/BALL VALVE BY P. (•) 3/4 W ►� ET -1 AMTROL THERMAL EXPANSION ABSORBER �-'�� 1' T & P REUEF VALVE BY P.C. 1" RUN FULL SIZE TO MOP SINK. DRAIN VALVE BY P.C. SHELF ABOVE MOP SINK, SHELF & BRACKETS BY GENERAL CONTRACTOR: 1' ACUUM BREAKER BY P.C. -HANGERS INSTALLED EACH SIDE OF EXP. TANK FOR SUPPORT c�-�iTQ—HW 3/415/ tl 1' TO MOP SINK WATER HEATER SCHEMATIC NTS OWER SUPPLY BY E.C. JUNC11ON BOX (TYP.) INSULAALL PIPING IN ACCOfDANCE WITH SPECIFICATIONS. UNION B (TYP.) P.C. WATER HATER SEE PLUMBINGFIXTURE SCHEDULE FOR ADDITION/ L INFO. 2" WIDE, a0 GA. SHEET ME(UAL BAND, SECURE T). WALL FOR SEISMIC BlACING WHERE i=QUIRED BY CODE. (B P.C.) -GALV. DRII BY P.C. 3/4" TO MOP SINK PIPING MATERIAL SPECIFICATIONS SANITARY SEWER AND VENT PIPING * PIPE NO—HUB CAST IRON PER CISP 301 * FITTINGS: NO—HUB CAST IRON PER ASTM C-564 * JOINTS: NO—HUB CAST IRON T PIPE OPTION * PIPE: COPPER DWV * FITTINGS: COPPER DWV DOMESTIC WATER * PIPE: COPPER TYPE "L" * FITTINGS: WROUGHT COPPER * JOINTS: LEAD FREE SOLDER * VALVES: BALL TYPE, NIBCO #S-580 OR EQUAL CONDENSATE PIPING SYSTEM * PIPE: COPPER TYPE "M" * FITTINGS: WROUGHT COPPER * JOINTS: LEAD FREE SOLDER ROOF AND OVERFLOW STORM DRAINAGE SYSTEM * INTERIOR UNDERGROUND: CAST IRON SOIL PIPE AND FITTINGS, BELL & SPIGOT HUB TYPE, SERVICE EIGHT, ASTM A74, HUBLESS CI PIPE WITH NEOPRENE RUBBER COMPRESSION GASKETS, ASTM C564. * INTERIOR UNDERGROUND: BELL & SPIGOT HUB TYPE CAST IRON SOIL PIPE AND FITTINGS, CISPI 301, WITH HUB TYPE COUPLINGS WITH STAINLESS STEEL CLAMPS, MISSION TYPE COUPLING BAND & CLAMP, HUSKY SERIES 4000, CLAMP — ALL HUB TYPE COUPUNG, CISPI 310, OR EQUAL NATURAL GAS * PIPE: ASTM A53, TYPE F, STANDARD WEIGHT, BLACK STEEL * FITTINGS: ASTM A197/ANSI B16.3, CLASS 150, BLACK MALLEABLE IRON, THREADED JOINTS. * UNIONS: MALLEABLE IRON, CLASS 250 PAN REFER TO SHEET M-300 FOR PLUMBING SPECIFICATIONS. 1SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical t3Plumbing Gas Piping City of Tukwila ELUDING DIVISION REVISIONS No changes shall bemade to the scope of work without prior approval of Tukwila Building Division. NOM: Revisions will require a new plan submittal and may include additional plan review flees. V 0 • OB -1 FOR BOTTLELESS COOLER 1 PLUMBING PLAN 1 /4"=1'-0" PLUMBING FIXTURE SCHEDULE BASIS OF DESIGN MANUFACTURER LISTED BELOW: EQUIVALENTS ACCEPTED AFTER REVIEW FIXTURE NO. FIXTURE TYPE WASTE VENT CW HW REMARKS SK -1 " 2 "FAUCET 1 2 ELKAY LRADQ2222 18 GAUGE TYPE 304 STAINLESS STEEL, SELF—RIMMING SINK WITH HOLE SPECIFICA I I'► • MODEL 2302 GOOSENECK FAUCET AND 0.5 GP,: : :• �' - ' i'• •1 02 CONFORMS TO ADA CHICAGO - SINK fa GARBAGE DISPOSAL__-" — — — IN—SINK—ERATOR BADGER 5XP 3/4 HP MOTOR .011 ELECTRIC WATER HEATER — — 3/4" 3/4" A.O. SMITH ELECTRIC WATER HEATER MODEL DEL -06, 1.5 KW, 6 GALLON. MOUNT ON SHELF ABOVE MOP SINK. PROVIDE WITH 4" DRAIN PAN AND AMTROL EXPANSION TANK MODEL THERM—X—TROL—ST-5—C. SEE DIVISION 16 DRAWINGS FOR VOLTAGE AND PHASE. EQUAL BY RHEEM OR RUUD LAV, UNDRECOUNTER MOUNTED LAVATORY 2" 1-1/2" 1/2" 1/2" KOHLER MODEL K-2030 GREENWICH — WHITE. UNDERMOUNT IN CORIAN COUNTER COLO NOCTURN. INSULATE PIPING BELOW COUNTER WITH "LAV—GUARD" FOR ADA COMPLIANCE. PROVIDE WITH TRITON FAUCETS MODEL K-7443 IN POLISHED CHROME WITH SECURE POP—UP DRAIN KNOB. PROVIDE WITH POUSHED CHROME DRAIN AND STRAINER. IE TRAP PRIMER — — 1/2" — JAY R. SMITH, PRIME EZE WATER SAVER TRAP PRIMER MODEL NO. 2698 WC_1 WATER CLOSET 4` 2" 2" 1/2" — KOHLER TOILET MODEL K-3529 DEVONSHIRE, WHITE, COMFORT HEIGHT, 1.6 GPF TANK TYPE, ADA COMPUANT WITH THE FOLLOWING: K-7637 ANGLE STOP, K -9167—L OR K -9167—R TRIP LEVER TO BE ON THE OPEN SIDE OF TANK SEAT HINGE ,TRIP LEVER, ANGLE STOP POUSHED CHROME K-4731—SC SEAT — BLACK I MOP SINK M 3 N 1-1/2 N 3/4 N 3/4 FIAT MSB -2424 MOLDED STONE MOP BASIN WITH VINYL BUMPER—GUARD; FURNISH WITH AMERICAN STANDARD 8344.111 FAUCET WITH INTEGRAL VACUUM BREAKER AND STOPS. PROVIDE MOP HANGER — SEE ARCH. DRAWINGS ED. FLOOR DRAIN 3" 1 1/2" — — J.R. SMITH 2010—B STRAINER, 4" SQUARE, CHROME FINISH PROVIDE TRAP PRIMER, ZURN ZARB-1022 SANI—GUARD, ALL BRONZE BODY, BODY WITH INTEGRAL VACUUM BREAKER, NON—LINING INTERNAL OPERATING ASSEMBLY WITH GASKET BRONZE COVER Lg. FLOOR CLEAN OUT SIZE — — — JOSAM SERIES NO. 55000—Z WITH NICKALOY ROUND CAP. WCO WALL CLEANOUT UNE SIZE — — — WALL CLEAN OUT — CAST IRON CLEAN OUT TEE WITH BRONZE THREADED CLEAN OUT PLUG. PLUG TO BE GAS AND WATER TIGHT. WALL ACCESS! PANEL — ZURN #ZANB-1460-9, 9" X 9" WALL ACCESS PANEL AND FRAME; SMOOTH NICKEL BRONZE SECURING LUGS. ACCEPTABLE ALTERNATES, WADE OR SMITH. MAYTHERMOSTATIC MIXING VALVE — — LI SINE SIZE POINT OF USE. WATTS MODEL MMV—US—M1. SET FOR 110' F ED -2 1 FUNNEL DRAIN A r, •:i a ;� — 1 • " - "_ - — - •r. *'l • L :Y J.R. SMITH OR WADE. FOR AHU CONDENSATE DISPOSAL — — 2" 2 Q. OUTLET BOX — — 1/2" — OUTLET BOX 10 WATER COOLER CONNECTIONS. OATEY OFFSET DRAIN #38791. PROVIDE WITH 1/2" CHECK VALVE., PROVIDE WITH 1/4 SHUT OFF VALVE. INSTALL OUTLET BOX AT 20" FROM FLOOR TO CENTER OF OUTLET BOX. DF -1 DRINKING FOUNTAIN 2" 1-1/2" 1/2" — ELKAY EZSTL8C WALL—MOUNTED BARRIER FREE, (ADA COMPLIANT) DUAL LEVER FRONT AND SIDE PUSH ACTUATOR BARS, STAINLESS STEEL BOWL, FLEXIBLE POLYESTER ELASTOMER SAFETY BUBBLE AND GALVANIZED STEEL FRONT AND SIDES, CHILLER WITH 80 GALLONS PER HOUR CAPACITY, 507 DRINKER WATER AT 807 INLET TEMPERATURES 907 ROOM TEMPERATURE; TRIM MCGUIRE 2165CC COMPRESSION ANGLE STOP VALVE WITH RISE ESCUTCHEON, MCGUIRE 8872CF 1-1/4" 17 GAUGE TUBULAR CHROME PLATED BRASS ADJUSTABLE P—TRAP AND WASTE ARM WITH CLEANOUT PLUG AND ESCUTCHEON, AND SUITABLE CARRIER WITH STANCHIONS TO FLOOR. 1 I+ 0 0 0 0 0 i ,1 1-1/2), REVIEWED FOR CODE COMPLIANCE APPROVED JUL 3 0 2013 City o T kwila BUILDIN !VISION 3/4" 1/2" TO FD LAY I '> . 1/2" OB -1 I 3/4" v I f1/2" li-e-1 /2" I iii_C=1. (-1/2" DF -1J 3/4" [L LAV RISER NTS PLUMBING CODED NOTES: CONNECT NEW 4" SANITARY UNE INTO THE LANDLORD'S EXISTING SANITARY SERVICE FIELD VERIFY EXACT LOCATION OF LANDLORD'S MAIN PRIOR TO BIDDING. INSTALL CLEAN OUT AT CONNECTION TO LANDLORD'S MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH. REFER TO STACK DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. COORDINATE WITH LANDLORD AND TENANT BELOW FOR BELOW FLOOR INSTALLATION. CONNECT NEW 2" VENT UNE FROM TENANTS PLUMBING FIXTURES TO LANDLORD PROVIDED VENT CONNECTION. FIELD VERIFY EXACT SIZE AND LOCATION. CONNECT NEW COLD WATER UNE INTO THE LANDLORD'S EXISTING WATER UNE FIELD VERIFY LOCATION OF WATER UNE PRIOR TO STARTING WORK. PROVIDE WITH WATER METER AND REMOTE READ OUT. VERIFY METER TYPE AND LOCATION WITH LANDLORD'S ON SITE FURNISH AND INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM AND AS REQUIRED PER PDI WH 201. UNITS AS SUPPUED BY SIOUX OR PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. ALL PLUMBING FIXTURES SHALL BE INSTALLED WITH STOP VALVES TO ISOLATE EACH FIXTURE. REFER TO RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR FURTHER INFORMATION. FILE COPY Permit No. V& /221-Q`i Plan review approval Is to ernxs and omissions. Approval of construction documents does not authorize or ordnance. Receipt BY City Of BUILDING DIVISION DOMESTIC HOT WATER 12r= MhTAXI VU WD ILA JUL 2013 PERMIT CENTER FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY TFIE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. T'G 13-- I 0 1r0 M -Engineering 750 Brooksedge Blvd. Westerville, Ohio 43081 phone: 614.839.4639 fax: 614.839.2222 All rights reserved. No part of these drawings or specifications may be copied, reproduced or used in connection with any work, other than the specific project for which they have been prepared, without prior written authorization from the Architect. ENGINEER OF RECORD: C REW Southcenter Mall .683.-Southcenter Mall Space No. 676 Seattle, WA 98188 Level: Ground Floor Project No. 1339 Project No. 13411114 NO. DATE ISSUE 07-17-13 Issue for Permit 07-17-13 Issue for Bid 07-17-13 Issue for LL & Client Review Plumbing Plan P-100