Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG13-111 - WILBUR ELLIS - ALTERATION
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. PG13-111 Wilbur Ellis 16300 Christensen Rd #200 DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As Personal Information – such, individuals’ social security numbers are Social Security Numbers 5 U.S.C. sec. redacted to protect those individuals’ privacy pursuant DR1 Generally – 5 U.S.C. sec. 552(a); RCW to 5 U.S.C. sec. 552(a), and are also exempt from disclosure under section 42.56.070(1) of the 552(a); RCW 42.56.070(1) Washington State Public Records Act, which exempts 42.56.070(1) under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit expiration Personal Information – RCW dates, or bank or other financial account numbers, 11 DR2 Financial Information – 42.56.230(5) which are exempt from disclosure pursuant to RCW RCW 42.56.230(4 5) 42.56.230(5), except when disclosure is expressly required by or governed by other law. WILBUR ELLIS 16300 CHRISTENSEN RD SUITE 200 PG13-111 City ofOukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No.: 2523049078 Address: 16300 CHRISTENSEN RD TUKW Project Name: WILBUR ELLIS Permit Number: PG13-111 Issue Date: 08/28/2013 Permit Expires On: 02/24/2014 Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE , PALO ALTO CA 94301 Contact Person: Name: DON WYCOFF Address: 8425 219 ST SE 102 , WOODINVILLE WA 98072 Email: DWYCOFF@SAGERMECHANICAL.COM Contractor: Name: SAGER MECHANICAL INC Address: 8425 219 ST SE, STE 102 , WOODINVILLE WA 98072 Contractor License No: SAGERMI088NK Expiration Date: 08/29/2013 Phone: 206 200-3749 Phone: 425 402-1930 DESCRIPTION OF WORK: SUITE 200: SHIFT LOCATION OF (1) SINK/WATER HEATER, ADD (10 NEW SINK/WATER HEATER, AND ROTATE PLUMBING FOR (1) SINK/WATER HEATER. Value of Plumbing/Gas Piping: $8,500.00 Uniform Plumbing Code Edition: 2009 Fees Collected: $261.88 International Fuel Gas Code Edition: 2009 Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this will be complied amin 'th, Date: d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The grant'. g of this p: rmit does not presu e to give authority to violate or cancel the provisions of any other state or local laws regulating construe ion or the p rformance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the • ack of this • - rmit. Signature: Print Name: Date: ,r 24 ^ �� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Mr^1'2 1.11 o.i n10r1 na_7n_')nli PERMIT CONDITIONS Permit No. PG 13-111 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. don. UPC -4110 PG13-111 Printed: 08-28-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: 02- �� (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2523049078 Site Address: 16300 Christensen Rd Tukwila, Wa 98188 Suite Number: 200 Floor: 2 Wilbur Elis 7 Tenant Name: PROPERTY OWNER Name: BRCP Riverview Plaza Address: City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Don Wycoff Address: 8425 219th St SE 102 City: Woodinville State: Wa Zip: 98072 Phone: (206) 200-3749 Fax: (425) 402-6721 Email: dwycoff@sagermechanical.com New Tenant: ❑ Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Sager Mechanical Address: 8425 219th ST SE 102 City: Woodinville State: Wa Zip: 98072 Phone: (425) 402-1930 Fax: (425) 402-6721 Contr Reg No.: sagermi088nk Exp Date: 08/10/2014 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 8,500 Scope of Work (please provide detailed information): Shift location of one (1) sink/water heater, add one (1) new sink/water heater, rotate plumbing for one (1) sink/water heater. Building Use (per Int'1 Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: l�/1I��LIR Sewer .. 1"n UV(Pii.Lw' H: ApplicationsWorms-Applications On Lme'20I 1 Applications\Plumbing Permit Application Revised 8-9-11 .docx Revised: August 201 I bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 3 Shower, single head trap Sinks 3 Rain water system — per drain (inside building) 3 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent 3 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBa- ERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENAL Y'OF P : ' JURY BY THE LAWS OF TH STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL NG r W R OR AUTHORIZEDI A Signator- . 07/ //4/ Print Name: Don Wyco Mailing Address: 8425 19 St SE 102 H:Wpplicanons\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 08/11/2013 Day Telephone: (206) 200-3749 Woodinville Wa 98072 City State Zip Page 2 of 2 r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049078 Address: 16300 CHRISTENSEN RD TUKW Suite No: Applicant: WILBUR ELLIS RECEIPT Permit Number: PG13-111 Status: PENDING Applied Date: 08/13/2013 Issue Date: Receipt No.: R13-02346 Initials: User ID: JEM 1165 Payment Amount: $261.88 Payment Date: 08/13/2013 12:11 PM Balance: $0.00 Payee: SAGER MECHANICAL, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2993 ' 261.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 52.38 000.322.103.00.00 209.50 Total: $261.88 Printed: 08-13-2013 INSPECTION RECORD (4t: �- INRe"tain a copy with permit INSPECTION NO. P613-11( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: , ill; (oo,� &I(. Type f Inspection: f J PtJi-te!/ Address: I LD 3 O D GL t.1 ST/ NS �„ 1V'Datl �d v G lio: r.1,,it./ Special Instructions: 5t/ :7—E CSO C) � . Date anted - !-a.m. - (3 p.m. Requester: Phone No: --5-o l Approved per applicable codes. Corrections required prior to approval. COMMENTS: ic\ft(e) Inspector: Dater n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. L. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 P613.10 Project:, Typq of Inspection ,. Address:Date 1 (403°0(rI S i eA1 en/ Called: Special Instructions: Date Wanted 129 _13 (a.m. ( P. Requester: Phonei 25- 2A 4 - ?3S-5 Approved per applicable codes. 1__.J Corrections required prior to approval. 3 COMMENTS: fiA- Rod' 221 r r e. 1- 2..-_ ^JM p I4 j `d 6--c r - TC -f`M-1( - --i--)0-._e--i--)0-._el `J r -e2 --- IA -A -4 -R P . Al jC7 --- -"Ai? ea p 4kj I I REINSPECTION FEE REQUIRED. Pri to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Ins ector: Date,�C ( 3 IPERMIT COORD COPY r. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-111 DATE: 08/13/13 PROJECT NAME: WILBUR ELLIS SITE ADDRESS: 16300 CHRISTENSEN RD, STE 200 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ,:wc 8 -)41 "5 Building Division f j Nirc efi 'IA - Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 08/15/13 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required El No further Review Required El APPROVALS OR CORRECTIONS: DUE DATE: 09/12/13 Approved ❑ Approved with Conditions Not Approved (attach comments) El Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Prin Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name SAGER MECHANICAL INC UBI No. 602234477 Phone 4254021930 Status Active Address 8425 219Th St Se Ste 102 License No. SAGERMI088NK Suite/Apt. License Type Construction Contractor City Woodinville Effective Date 8/12/1992 State WA Expiration Date 8/29/2013 Zip 98072 Suspend Date County King Specialty 1 Plumbing Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date SAGER, ROBERTT President 08/12/1992 Bond Amount SAGER, ANDREW VINCENT Vice President ' 08/12/1992 01/10/2008 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 American Contractors Indem CO 100204990 09/27/2012 Until Cancelled $4,000.00 $6,000.00 10/02/2012 4 Great American Ins Co 1698496 09/27/2011 Until Cancelled 09/27/2012 $6,000.0009/27/2011 04/25/2011 3 TRAVELERS CAS & SURETY 104575403 07/19/2005 Until Cancelled 09/28/2011 10/13/2011 $6,000.0008/02/2005 04/28/2010 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 8/11/1992 Until Released Bond 05/01/2014 $4,000.00 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 Continental Western Ins Co cnp2758827 05/01/2012 05/01/2014 $1,000,000.0004/25/2013 11 Continental Western Ins Co CNP275882724 05/01/2011 05/01/2012 $1,000,000.00 04/25/2011 10 Continental Western Ins Co cnp275882721 05/01/2009 05/01/2011 $1,000,000.00 04/28/2010 9 CONTINENTAL WESTERN INS CNP253520423 05/01/2008 05/01/2009 $1,000,000.00 06/27/2008 8 CONTINENTAL WESTERN GROUP CNP2535204 08/10/2007 08/10/2008 $1,000,000.0007/31/2007 Summons/Complaint Information Cause County Complaint Judgment Status Payment Paid By 11-2-28941-9SEA PACIFIC PLUMBING SUPPLY CO LLC KING Date: 08/24/2011 Amount: $5,424.17 Date: Amount: $0.00 Open Date: 10/13/2011 Amount: $3,403.38 Bond https://fortress.wa.gov/lni/bbip/Print.aspx 08/28/2013 z 20'-0" 20'-0" 20'-0" 10 120'-0" .19 PRIVATE 2103 OFEN 2102 PRIVATE ii 2205 CONFERENCE ROOM 1 2206 1 20'-0" PRIVATE 2207 COFFEE' 121.04 RLEM 12105 (N) (18"AFF) AV (N)(52 AFF) AV (N)(19 AFF) 0 0 0 0 )� 0 0 0 REA 2106 J 2100 2101 A 0 CONFERENCE ROOM X1_2204 11/2" 4 - 1.; 2205 8'-4" PRIVATE OFFleF 1 2208 1 OPEN 2202 20'-0" PRIVATE oFFICF 1 2209 1 PRIVATE OFFU:F 1 2210 20'-0" AIM 011111111i' I A,N L 0 �� 1. .nr o OPD1 e,i y o _' !IVY 2235 N TYP. 8 ALIGN N9I V 1191 Gm <N BREAK AF EA MI 18'-0" AV (N)( 2"AFF) CONFERENCEc ? (52 -AFF) ROOM AV (N)(52"AFF) (N) (52"AFF) AV (N)(52"AFF) 2231 ® PN PRIVATE 6.41.11 N 2200 AREA 1 2201 1 +N 2 Z• -- OM 1 2211 1 a z Z v EQUIPMENT STORAGE 122301 4 N PRIVATE 20'-0" 20'-0" 20'-O" REVISIONS No changes shall be made to the scope c# 'fork without prior approval of ' `-r.�=1a Building Division. -A i -::Sona will squire a new plan submittal d may include additional plan review fees. 20'-0" 20'-0" CONFERENCE ROOM 1 2213 1 O'N E /3V C-2 OPEN.. OFFICE 2229 OPIN OFFICE 2228 IGN PRIVATE OFFICE 43) ORFFIC�F G 1 2226 1 3c OPEN OFFICE 2225 PRIVATE i O 2223 PRN 2215 PRIVATE OFFICE 12218 1 v1/41134 � v 11-2" 4 .o 0 OPEN Cala 7219 J SEPARATE PERMIT' `F OU1RI D FOR: lirMechanicai Pet lectricat 0 Plumbing [was piping City of Tukwila I ° 1..DING DIVISION OPEN OFFICE 2220 R&D NETWORK LAB 2222 Key Notes: Key t .tes: 4 FI ` COPY Permit No. Pl^^ review approval is to emus and omissions. A. :::ki of constniction documents does n• authorize icy adopted code or .- Receipt Rrt i r � o a Fielo copy and F .' + I I 1 : *4. . :.. 1 •f City Of Tbkwita BUILDING DIVISION REVIEWED FOR CODE COMP1_IANC¢ APPROVED AUG 2 3 2013 City of Tukwila BUILDING DIVISION RECEIVED env o' TI HomtA AUG 13 2013 PFRA4re' Ili 1 TEF.. 0 RELOCATED COFFEE/KITCHEN CABINETS. PROVIDE NEW PLAM TOP, NOT USED O PROVIDE BACKING FOR WALL MOUNTED SCREENS SIDE BY SIDE. PROVIDE OUTLETS, NETWORK AND DOUBLE GANG BOX BEHIND EACH SCREEN AT 18" A.F.F.. PROVIDE 2" FLEX CONDUIT CONNECTIONS AV BOXES AND UNDER TABLE. ® PROVIDE ELECTRICAL CONNECTION OF TENANT PROVIDED SYSTEM FURNITURE. ASSUME 8 WIRE POWERED PANEL SYSTEM. PROVIDE PATHWAY FOR TENANTS LOW VOLTAGE CABLING ASSUMING 2 CABLES PER DESK. O PROVIDE BACKING FOR WALL MOUNTED A.V. DISPLAY. PROVIDE OUTLET, NETWORK, AND DOUBLE GANG AV BOX BEHIND SCREEN AND ® 18" A.F.F. PROVIDE 2" FLEX CONDUIT CONNECTIONS A.V. BOXES. © NEW 4'X10' BACK PAINTED GLASS WRITING SURFACE. REFER TO ELEV. 5/1-8.1. O7 3/8" TEMPERED GLASS WALL BUTT GLAZED WITH 3M PRIVACY FILM. WILBUR ELUS LOGO INCORPORATED ONTO THE DESIGN. (D, PC CONFIGURATION LAB, ASSUME 8 PC'S OPERATING AT ONE TIME FOR HVAC DESIGN. NEW::, BLDG. STANDARD RECITE: Symbols Legend: FFP• Partition Legend: BUILDING STANDARD FIRE EXTINGUISHER' CABINET (OR SPEC) 4) DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE aQ GFI DUPLEX RECEPTACLE FOURPLEX RECEPTACLE lito DEDICATED FOURPLEX RECEPTACLE C) CORE DRILL PROVIDE POWER AND NE' F., RK/PHONE JACKS QQ J -BOX FOR TENANT PROVIDED SYSTEI. `1JRNITURE. 4 VOICE/DATA RECEPTACLE. CONTRACTCF.,-, PROVIDE MUD RING AND PULL STRING OR PROXIMITY CARD READER ®-- WALL TAG JPC ARCHITECTS 909 112th Avenue NE Suite 206 Bellevue, WA 98004 NO DESIGNATION a EY, N = NEW=:hR RELOCATED (COORDINATE RELOCATED ITEMS `./ARCHITECT) D = DEM01.'3H 05.20.13 PERMIT SET DESIGN JPC VViIbirEIVc 1 DRAWN RC CHECKED DB 2nd Floor Expansion No. 130303 Riverview Plaza 16300 Christensen Rd. Seattle, WA 98188 EXISTING PARTITION TO BE REMOVED DOSING PARTITION/CONSTRUCTION TO REMAIN EXISTING SHELL & CORE WALLS GRID HEIGHT PARTITION. RVER TC DETAIL 3/1-9.1. NOT USED FULL HEIGHT PARTITION TO STRUCTURE. REFER TO DETAIL 5/1-9.1 2nd Floor Plan 1-3.2 O 2019,,, ArchB.ds, nix o V fi dh ® PN PRIVATE 6.41.11 N 2200 AREA 1 2201 1 +N 2 Z• -- OM 1 2211 1 a z Z v EQUIPMENT STORAGE 122301 4 N PRIVATE 20'-0" 20'-0" 20'-O" REVISIONS No changes shall be made to the scope c# 'fork without prior approval of ' `-r.�=1a Building Division. -A i -::Sona will squire a new plan submittal d may include additional plan review fees. 20'-0" 20'-0" CONFERENCE ROOM 1 2213 1 O'N E /3V C-2 OPEN.. OFFICE 2229 OPIN OFFICE 2228 IGN PRIVATE OFFICE 43) ORFFIC�F G 1 2226 1 3c OPEN OFFICE 2225 PRIVATE i O 2223 PRN 2215 PRIVATE OFFICE 12218 1 v1/41134 � v 11-2" 4 .o 0 OPEN Cala 7219 J SEPARATE PERMIT' `F OU1RI D FOR: lirMechanicai Pet lectricat 0 Plumbing [was piping City of Tukwila I ° 1..DING DIVISION OPEN OFFICE 2220 R&D NETWORK LAB 2222 Key Notes: Key t .tes: 4 FI ` COPY Permit No. Pl^^ review approval is to emus and omissions. A. :::ki of constniction documents does n• authorize icy adopted code or .- Receipt Rrt i r � o a Fielo copy and F .' + I I 1 : *4. . :.. 1 •f City Of Tbkwita BUILDING DIVISION REVIEWED FOR CODE COMP1_IANC¢ APPROVED AUG 2 3 2013 City of Tukwila BUILDING DIVISION RECEIVED env o' TI HomtA AUG 13 2013 PFRA4re' Ili 1 TEF.. 0 RELOCATED COFFEE/KITCHEN CABINETS. PROVIDE NEW PLAM TOP, NOT USED O PROVIDE BACKING FOR WALL MOUNTED SCREENS SIDE BY SIDE. PROVIDE OUTLETS, NETWORK AND DOUBLE GANG BOX BEHIND EACH SCREEN AT 18" A.F.F.. PROVIDE 2" FLEX CONDUIT CONNECTIONS AV BOXES AND UNDER TABLE. ® PROVIDE ELECTRICAL CONNECTION OF TENANT PROVIDED SYSTEM FURNITURE. ASSUME 8 WIRE POWERED PANEL SYSTEM. PROVIDE PATHWAY FOR TENANTS LOW VOLTAGE CABLING ASSUMING 2 CABLES PER DESK. O PROVIDE BACKING FOR WALL MOUNTED A.V. DISPLAY. PROVIDE OUTLET, NETWORK, AND DOUBLE GANG AV BOX BEHIND SCREEN AND ® 18" A.F.F. PROVIDE 2" FLEX CONDUIT CONNECTIONS A.V. BOXES. © NEW 4'X10' BACK PAINTED GLASS WRITING SURFACE. REFER TO ELEV. 5/1-8.1. O7 3/8" TEMPERED GLASS WALL BUTT GLAZED WITH 3M PRIVACY FILM. WILBUR ELUS LOGO INCORPORATED ONTO THE DESIGN. (D, PC CONFIGURATION LAB, ASSUME 8 PC'S OPERATING AT ONE TIME FOR HVAC DESIGN. NEW::, BLDG. STANDARD RECITE: Symbols Legend: FFP• Partition Legend: BUILDING STANDARD FIRE EXTINGUISHER' CABINET (OR SPEC) 4) DUPLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE aQ GFI DUPLEX RECEPTACLE FOURPLEX RECEPTACLE lito DEDICATED FOURPLEX RECEPTACLE C) CORE DRILL PROVIDE POWER AND NE' F., RK/PHONE JACKS QQ J -BOX FOR TENANT PROVIDED SYSTEI. `1JRNITURE. 4 VOICE/DATA RECEPTACLE. CONTRACTCF.,-, PROVIDE MUD RING AND PULL STRING OR PROXIMITY CARD READER ®-- WALL TAG JPC ARCHITECTS 909 112th Avenue NE Suite 206 Bellevue, WA 98004 NO DESIGNATION a EY, N = NEW=:hR RELOCATED (COORDINATE RELOCATED ITEMS `./ARCHITECT) D = DEM01.'3H 05.20.13 PERMIT SET DESIGN JPC VViIbirEIVc 1 DRAWN RC CHECKED DB 2nd Floor Expansion No. 130303 Riverview Plaza 16300 Christensen Rd. Seattle, WA 98188 EXISTING PARTITION TO BE REMOVED DOSING PARTITION/CONSTRUCTION TO REMAIN EXISTING SHELL & CORE WALLS GRID HEIGHT PARTITION. RVER TC DETAIL 3/1-9.1. NOT USED FULL HEIGHT PARTITION TO STRUCTURE. REFER TO DETAIL 5/1-9.1 2nd Floor Plan 1-3.2 O 2019,,, ArchB.ds, nix SCOPt OF WORK (11 2nd Floor Demolition Plan -Scale: 1/6'1'-0` Scale: 1/8"=1'-0" r L 20'-0" 4y 20'-0" i 20'—O" 20'—O" 20'—O" 1 C ?G3l1t • nen co _ I 0) N O M REVIEWED FOR CODE COMPLIANCE APPROVED AUG 932013 ,.r City of Tukwila BUILDING DIVISION Key Notes: Partition Legend: OO NOT USED ® DEMOLISH EXISTING FCARPET IN ALL AREAS, UNLESS OTHERWISE INDICATED. PATCH AND REPAIR AFFECTED SUBSTRATE AS REQUIRED FOR INSTALLATION OF NEW FINISH FLOORING AND BASE MATERIALS. REFER TO FLOOR AND FINISH PLAN FOR ADDITIONAL INFORMATION. O3 DEMOLISH EXISTING PARTITION WALLS (PARTIAL, GRID HEIGHT & FULL HEIGHT) PROTECT EXISTING ADJACENT SURFACES, INCLUDING BUT NOT LIMITED TO CEILING, ADJACENT WALLS AND FLOORING. REFER TO FLOOR PLAN FOR ADDTfIONAL INFORMATION. ® REMOVE EXISTING DOORS, FRAMES, SIDELTIES AND HARDWARE (UNLESS OTHERWISE REQUESTED TO BE RETAINED). CONFIRM SALVAGE REQUIREMENTS WITH LANDLORD. O DEMOLISH AND DISPOSE OF EXISTING KITCHENETTE CABINETRY (UNLESS OTHERWISE REQUESTED TO BE RETAINED). TERMINATE AND CAP ALL EXISTING SUPPLY/WASTE LINES BEHIND WALL AND/OR FLOOR. PATCH AND REPAIR AFFECTED AREAS, INCLUDING BUT NOT LIMITED TO WALLS, FLOORS AND CEILINGS AS REQUIRED MATCHING EXISTING FINISH MATERIALS, UNLESS NOTED OTHERWISE. © CABINETRY TO BE LOCATED TO ROOM 2221. GC TO ALTER CONFIGURATIONS AS REQUIERED FOR THE REINSTALLATION. EXISTING PARTITION TO BE REMOVED EXISTING PARTITION/CONSTRUCTION TO REMAIN EXISTING SHELL & CORE WALLS RECEIVED C11I' i OF TUI(WItA AUG 13 2013 et -J 4115 ENTER JPC ARCHITECTS 909 112th Avenue NE Suite 206 Bellevue, WA 98004 Wilbur Ellis 2nd Floor Expansion Riverview Plaza 16300 Christensen Rd. Seattle, WA 98188 05.20.13 PERMIT SET DESIGN JPC DRAWN RC CHECKED DB NO. 13-0303 2nd Floor Demolition Plan I-1.2 © 2013, JPC Architects, PLLC 5 L'1 4' '' ." Gam ;it of • „sty tij J V a�,-, t V�1 h (kits "t/ 14 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 7 3 2013 City of Tukwila BUILDING DIVISION pcTrIVED .KCIVILA AUG 13 20131 .4I I ;ENTER SCALE: / 'Q � 144 1 APPROVED BY: DATE:! 4. • , 064e1 freerriC trrn/ty w 51-4,'/4 N?` [RAWN' BY REVISED DRAWING T+ IMDER PG3 111