HomeMy WebLinkAboutPermit PG13-128 - TARGET - ALTERATIONTARGET
301 STRANDER BLVD
EXPIRED 04/13/14
PG13-128
Parcel No.:
Address:
City ofTukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
2623049005
301 STRANDER BL TUKW
Project Name: TARGET
PLUMBING/GAS PIPING PERMIT
Permit Number:
Issue Date:
Permit Expires On:
PG13-128
10/15/2013
04/13/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
Address:
TARGET CORPORATION T 0627
C/O PROPERTY TAX/TPN 0950 , PO BOX 9456 55440
ERIC DIXON
124 SW 156 ST, STE 204 , BURIEN, WA 98166
PRECISIONHEAT@COMCAST.NET
Phone: 206 393-0681
PRECISION PLUMBING & HEATING Phone: 206-393-0681
124 SW 156 ST, APT 204 , BURIEN, WA 98166
Contractor License No: PRECIPH894CW
Expiration Date: 02/16/2015
DESCRIPTION OF WORK:
INSTALL REPLACEMENT GREASE INTERCEPTOR
Value of Plumbing/Gas Piping:
Fees Collected:
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
$3,754.00 Uniform Plumbing Code Edition: 2009
$104.38 International Fuel Gas Code Edition: 2009
xami
with,
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions
on the back of this permit.
Signature:
Print Name:
61, /vCCcc�rtid
Date: S/ /
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
on, z_,'1n Printprl• 10_15-7013
PERMIT CONDITIONS
Permit No. PG 13-128
1: ***PLUMBING AND GAS PIPING***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila
Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing
inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas
Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code.
Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to
make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless,
adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the
conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be
protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing
piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in
accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to
twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill,
frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the
jurisdiction.
13: ***PUBLIC WORKS DEPARTMENT CONDITIONS***
14: Grease trap shall be installed per manufacturer's specification.
loc: UPC -4/10
PG 13-128 Printed: 10-15-2013
CITY OF TUKWI
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
111
Plumbing/Gas Permit No. I) & h V
Project No. 'I., j
Date Application Accepted: DA .J,
Date Application Expires: 079 6K (14
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 3 0 I 5 -kr
ander' RI vel
Tenant Name:
--fi-10.1-e+
PROPERTY OWNER
Name: r 9 e...± . .
Address: 10 ( SA..t�,.a-e.✓ r5( v d
City: T<
w (1 State: w A. Zip: Cts 198
CONTACT PERSON — person receiving all project
communication
Name: eYi C b, X 0 n
Address: 12 4 s W 15 let S+.. &k U 4
City: 13 (AAA it in State: w pi. Zip: i g /b,
Phone: 2Ob•3 93.064( Fax: N/A..
Email: prect'si o,n head 62 eoincaaf. rye
King Co Assessor's Tax No.: 2 (p2 3 Oji ci 0 0 5
Suite Number: Floor:
New Tenant.: E] Yes No
PLUMBING CONTRACTOR INFORMATION
Company Name: Prec i ti 0 n .vI U.rh 6 its 4 t NI_
Address: 12.4 5 w is le -n at. s -f e 2.04
City: 3 0.14 er State: W A. Zip: `y / 44
Phone: zoo. 3 9,3 . 0 &g, Fax: N14
Contr Reg No.: PRFci of $ %a g Jxp Date: 2 //&// 5 -
Tukwila
Tukwila Business License No.: GK. 5_ 0 4 g l to Q S
Valuation of Project (contractor's bid price): $ 3 1 54 • o O
Scope of Work (please provide detailed information):
I n S -f- /99 /a e -e rhea.s e / Cr e-er 4vr
Building Use (per Int'l Building Code) -
Occupancy (per Int'! Building Code):
Utility Purveyor: Water Sewer
H:Wpplicattore\Fonns-Applications On Line \ 2011 Applications\Plumbing Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
(
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: �'� ✓ U t--�
Print Name: Ta (l a !V` a✓i AO
Mailing Address: 121- S W 16 1d' S -f. . Sfe 2-04
Date: q ! 3
Day Telephone: ZO G • 3/ 3 ' 066/
Ru.4 e el Wfl- 4 8/bb
H:\Applicatiora\Forma-Applications On L ine\2011 Applications\Plumb ng Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
City State Zip
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
RECEIPT
Parcel No.: 2623049005 Permit Number: PG13-128
Address: 301 STRANDER BL TUKW Status: PENDING
Suite No: Applied Date: 09/16/2013
Applicant: TARGET Issue Date:
Receipt No.: R13-02637
Initials:
User ID:
JEM
1165
Payment Amount: $104.38
Payment Date: 09/16/2013 01:59 PM
Balance: $0.00
Payee: TALIA ROSE MARINO, PRECISION PLUMBING & HEAT
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd MC
Authorization No. 050017
ACCOUNT ITEM LIST:
Description
104.38
Account Code Current Pmts
PLAN CHECK - NONRES
PLUMBING - NONRES
000.345.830 20.88
000.322.103.00.00 83.50
Total: $104.38
Printed: 09-16-2013
TARGET
MEI Py
Pte--- •• - .
B172188: T — 0627 SOUTH CENTER, WA DATE: 4-24-2013
Project Description
Existing grease interceptor is at the end of its useful life. Scope of this project includes replacing the
existing grease interceptor with a new unit manufactured by Schier ProductsTM'. All required permits
and inspections are the responsibility of the contractor.
Scope of Work
Interior replacement:
Prior to beginning work, measure the Invert of the existing grease trap. Verify the
Great Basin GB -25 invert will work. Please include rework of sanitary waste piping if
the invert does not work.
1. Saw cut and remove concrete slab approx 3 ft X 6 ft.
2. Open trench approx 3 ft. deep.
3. Remove existing grease interceptor and install a new Schier, Great Basin model GB -25, 3"
connection, fumished by Target and installed by the contractor.
a. Coordinate riser height options based on distance of grease interceptor from furthest
fixture.
4. Connect inlet and outlet of grease interceptor to existing sanitary sewer lines, verifying prior to
installation the width of the new interceptor will fit next to existing sanitary sewer pipes.
5. Hydro jet existing line.
6. Test for proper operation.
7. Patch existing concrete floor with compressive strength f,= 3000 psi, floor mix, max WIC =
0.55, 3-4" slump.
8. Patch floor tile to match. Ceramic Tile provided by Target Procurement. Grout, mastic,
underlayment, etc. provided by Contractor.
9. Clean-up and dust control per food safety standards.
10. All work to be performed after store hours.
11. Per archived drawings available, existing floor tile is
a. Contractor shall verify the quantity and match is acceptable prior to install.
Attachments - Existing under floor plumbing plan
New under floor plumbing plan
Great Basin GB -25 cut sheet
Great Basin Request for Approval
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 2 3 2013
City of Tukwila
BUILDING DIVISION
END OF SCOPE OF WORK
RECEIVFr
SEP. 17 2013
TUKVviL„
PUBLIC WORKS
RECEIVED
CITY OF TUKWILA
SEP 1 3 2013
PERMIT CENTER
1 of 1
O:\Special_Proj ects\BCT# 172188-
2013_Greasetrap_Replacement\0627_WA_SouthCenter\_ActiveCAD\T0627_SouthCenter_
WA GI Int SOW.docx
F(i1r- \vg
REVISIONS
Nc changes shall be made to the scope
of work Vthout prior approval of
Tukwita Building Division.
I NcilTE: Revisions will require a new plan submit,'
1 ar d may include additional plan review fccs. - --ij
SEPAR)TE PERMIT
REQUIRE.D FOR:
VISI- Mechanical
gElectrical,
F lumbing
Gas, Piping
My of Tukwila
DIVISION
13.
'
EXISTING FOOD SERVICE
UNDERFLOOR PLUMBING
PLAN
CO
0
Perr
Plan review
Approval of
th'p violator
'If approved
By
FILE COPY
nitNo.
approval is subject to errors and omissions.
construction documents does not authoilze
of any adopted code or ordnance. Receipt
Field Copy and conditions is acknowledged:
/(X.
REVIEWED FOR
:CODE COMPLIANCE
APPROVEI?
-SEP 2 3 2013
City oil -
BUILDING D
- 'O-;
.4. 4
St/Ao-\ ex* k\,M&ctipe\ ,
\JtAYJsb atAd peAr,
A vek
e_CC
I
I
'
i i ; ; •
I- ; ..•-•T:" ',7,---7 i ' .; , ! I
r, .
..._.
0
GREASE TRAP
JOSAM MODEL 60145 FLUSH
WITH FLOOR - 20 GPM FLOW
RATE - 40 LB. GREASE CAP.
r THREADED CONNECTION
/0
City Of Tukwila
BUILDING DIVISION
RECENTIFTI
SEP. 1 7 2013
TUNA
PUBLIC WORKS -
RECEIVED
CITY OF TUKWILA
SEP 1 3 2013
PERMIT CENTER
1761S -12_4g
REVIEWED FOR
CODE COMPLIANCE
APPROVED
SEP 2 3 2013,
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
SEP 1 3 2013
PERMIT CENTER
SPECIFICATIONS (GB -25)
1. 3" inlet/outlets Sch. 40. (No -Hub)
2. Max flow rate: 25 GPM
3. Liquid capacity: 22 Gallons
4. Max grease capacity: 75 lbs. (10.4 Gallons)
5. Max solids/sediment capacity: 2 Gallons
6. Unit weight w/std. covers: 31 lbs.
7. Standard bolted, gasketed, gas/water tight composite
covers handle 450 lbs. when unit is directly buried and
a 2,500 lbs. load when buried in SR16 riser.
8. Maximum operating temperature 190°F continuous.
NOTES
1. Listed by IAPMO to ASME grease interceptor
standard #A112.14.3
2. Factory installed Built -In Flow control.
3. For gravity drainage applications only. Do not use
for pressure applications.
4. 3/8" thick seamless high density polyethylene walls.
5. Riser is also available for burial.
6. Cover placement allows full access to tank for proper
maintenance.
7. Vent not required unless per local code.
8. Engineered inlet and outlet diffusers are removabl
to inspect/clean piping.
9. For on -the -floor or buried applications.
10. Integral Air Relief / Anti -siphon.
11. Three outlet options for easy rough in. Unit
shipped with outlet diffuser in outlet "B".
DIFFUSION FLOW TECHNOLOGY
The inlet diffuser splits incoming effluent into two paths
that utilize the entire liquid volume of the tank for efficient
grease separation. The calibrated openings greatly reduce
effluent turbulence. The effluent enters the main chamber
without disturbing the existing grease or sediment layers.
27"
Outlet "A"
(Optional)
21"
REVIEVVEL) rOR
CODE COMPLIANCE
APPROVED
SEP 2 3 2013
A
City of Tukwila
BUILDINGf ? II N
inlet and outlet
The integral air relief/anti-siphon in the top of the outlet diffuser
allows pressure stabilization within the unit during operation.
The bottom of the outlet diffuser allows only effluent which is free of
grease to exit the tank. It can easily be attached to any
of the three outlets provided to ease jobsite piping layouts.
ENGINEER SPECIFICATION GUIDE
Schier Great Basin TM grease interceptor model # shall
be lifetime guaranteed and made in USA of seamless, rotationally -
molded High Density Polyethylene with minimum 3/8" uniform wall
thickness. Interceptor shall be furnished for above or below grade
installation. Interceptor shall be built in accordance to ASME A112.14.3
(type C), with field adjustable riser system, built-in flow control, built-in test
caps and three outlet options. Interceptor flow rate shall be GPM.
Interceptor grease capacity shall be lbs. Cover shall provide
water/gas-tight seal and have minimum 2,000 lbs load capacity.
OPTIONS:
• Teleglide field adjustable risers for extending covers to grade
• Male pipe thread connections
• 2" Plain end pipe or male pipe thread connections
• Clamping collar kit
greose
nil
6eporMars
solids
chemical
Interceptors waste tanks
process
systems
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SCHIER PRODUCTS. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SCHIER PRODUCTS IS
PROHIBITED.
15"
4-1/4"
10-3/4"
Outlet "C"
(Optional)
TOP VIEW
0 16" Cover
Static water
line
6-1/4"
A
Outlet "B"
(Standard)
i
9" invert
Engineered inlet and
outlet diffuser
(see discription)
SECTION "A -A"
PART NUMBER: GB -25
Deep structural
reinforcing columns
ISOMETRIC VIEW
21"
END VIEW
Visa
SPECIFICATION SHEET
DESCRIPTION:
GREAT BASIN SERIES POLYETHYLENE
GREASE INTERCEPTOR 25 GPM, 22 LIQUID
GALLONS, 75 GREASE POUNDS CAPACITY
DWG BY: TEU DATE: 10/17/11 REV: 0
MATL: PE
Schier Products
9500 Woodend Road
Edwardsville, KS 66111
Tel: 800-827-7119
Fax: 800-827-9664
www.schierproducts.com
Made in the U.S.A
SCHIER
PRODUCTS
Pioneering Drain Line Purity
RECEIVED
CITY OF TUKWILA
SEP 1 3 2013
PERMIT CENTER
3/3/2014
City of Tukwila
Department of Community Development
ERIC DIXON
124 SW 156 ST, STE 204
BURIEN, WA 98166
RE: Permit No. PG13-128
TARGET
301 STRANDER BL
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
New Inspection Request Line
206 438-9350
.In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of
such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun
for a period of 180 days. Your permit will expire on 4/13/2014.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 4/13/2014, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall
t Technician
File No: PG 13-128
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
' PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: PG13-128
PROJECT NAME: TARGET
DATE: 09/16/13
SITE ADDRESS: 301 STRANDER BL
X Original Plan Submittal
Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
Building Division
TS C 0711Vir5
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete IA
Incomplete
DUE DATE: 09/17/13
Not Applicable
Comments:
`Permit Ce'nte'r Use Only' ,-=:-
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route �+
REVIEWER'S INITIALS: DATE:
Structural Review Required ❑
No further Review Required ❑
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Approved with Conditions
DUE DATE: 10/15/13
Not Approved (attach comments) ❑
DATE:
:n..F Etr.
Permit Center_Use.Only'
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0
Ping ❑ PW ❑
Staff Initials:
1
Joanna Spencer
From: Todd Reedy
Sent: Tuesday, September 17, 2013 12:42 PM
To: Joanna Spencer
Subject: RE: Target @ 301 Strander Blvd PG13-128
Hi Joanna,
Target @ 301 Strander is current on backflow preventer installation and testing.
Have a good day,
Todd
From: Joanna Spencer
Sent: Tuesday, September 17, 2013 9:38 AM
To: Todd Reedy
Cc: Han Kirkland
Subject: Target @ 301 Strander Blvd PG13-128
Good Morning Todd,
Are they current on their backflows ?
Joanna