Loading...
HomeMy WebLinkAboutPermit PG13-128 - TARGET - ALTERATIONTARGET 301 STRANDER BLVD EXPIRED 04/13/14 PG13-128 Parcel No.: Address: City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov 2623049005 301 STRANDER BL TUKW Project Name: TARGET PLUMBING/GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG13-128 10/15/2013 04/13/2014 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: TARGET CORPORATION T 0627 C/O PROPERTY TAX/TPN 0950 , PO BOX 9456 55440 ERIC DIXON 124 SW 156 ST, STE 204 , BURIEN, WA 98166 PRECISIONHEAT@COMCAST.NET Phone: 206 393-0681 PRECISION PLUMBING & HEATING Phone: 206-393-0681 124 SW 156 ST, APT 204 , BURIEN, WA 98166 Contractor License No: PRECIPH894CW Expiration Date: 02/16/2015 DESCRIPTION OF WORK: INSTALL REPLACEMENT GREASE INTERCEPTOR Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie $3,754.00 Uniform Plumbing Code Edition: 2009 $104.38 International Fuel Gas Code Edition: 2009 xami with, Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: 61, /vCCcc�rtid Date: S/ / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. on, z_,'1n Printprl• 10_15-7013 PERMIT CONDITIONS Permit No. PG 13-128 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: ***PUBLIC WORKS DEPARTMENT CONDITIONS*** 14: Grease trap shall be installed per manufacturer's specification. loc: UPC -4/10 PG 13-128 Printed: 10-15-2013 CITY OF TUKWI Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov 111 Plumbing/Gas Permit No. I) & h V Project No. 'I., j Date Application Accepted: DA .J, Date Application Expires: 079 6K (14 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3 0 I 5 -kr ander' RI vel Tenant Name: --fi-10.1-e+ PROPERTY OWNER Name: r 9 e...± . . Address: 10 ( SA..t�,.a-e.✓ r5( v d City: T< w (1 State: w A. Zip: Cts 198 CONTACT PERSON — person receiving all project communication Name: eYi C b, X 0 n Address: 12 4 s W 15 let S+.. &k U 4 City: 13 (AAA it in State: w pi. Zip: i g /b, Phone: 2Ob•3 93.064( Fax: N/A.. Email: prect'si o,n head 62 eoincaaf. rye King Co Assessor's Tax No.: 2 (p2 3 Oji ci 0 0 5 Suite Number: Floor: New Tenant.: E] Yes No PLUMBING CONTRACTOR INFORMATION Company Name: Prec i ti 0 n .vI U.rh 6 its 4 t NI_ Address: 12.4 5 w is le -n at. s -f e 2.04 City: 3 0.14 er State: W A. Zip: `y / 44 Phone: zoo. 3 9,3 . 0 &g, Fax: N14 Contr Reg No.: PRFci of $ %a g Jxp Date: 2 //&// 5 - Tukwila Tukwila Business License No.: GK. 5_ 0 4 g l to Q S Valuation of Project (contractor's bid price): $ 3 1 54 • o O Scope of Work (please provide detailed information): I n S -f- /99 /a e -e rhea.s e / Cr e-er 4vr Building Use (per Int'l Building Code) - Occupancy (per Int'! Building Code): Utility Purveyor: Water Sewer H:Wpplicattore\Fonns-Applications On Line \ 2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) ( Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: �'� ✓ U t--� Print Name: Ta (l a !V` a✓i AO Mailing Address: 121- S W 16 1d' S -f. . Sfe 2-04 Date: q ! 3 Day Telephone: ZO G • 3/ 3 ' 066/ Ru.4 e el Wfl- 4 8/bb H:\Applicatiora\Forma-Applications On L ine\2011 Applications\Plumb ng Permit Application Revised 8-9-11.docx Revised: August 2011 bh City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049005 Permit Number: PG13-128 Address: 301 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 09/16/2013 Applicant: TARGET Issue Date: Receipt No.: R13-02637 Initials: User ID: JEM 1165 Payment Amount: $104.38 Payment Date: 09/16/2013 01:59 PM Balance: $0.00 Payee: TALIA ROSE MARINO, PRECISION PLUMBING & HEAT TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 050017 ACCOUNT ITEM LIST: Description 104.38 Account Code Current Pmts PLAN CHECK - NONRES PLUMBING - NONRES 000.345.830 20.88 000.322.103.00.00 83.50 Total: $104.38 Printed: 09-16-2013 TARGET MEI Py Pte--- •• - . B172188: T — 0627 SOUTH CENTER, WA DATE: 4-24-2013 Project Description Existing grease interceptor is at the end of its useful life. Scope of this project includes replacing the existing grease interceptor with a new unit manufactured by Schier ProductsTM'. All required permits and inspections are the responsibility of the contractor. Scope of Work Interior replacement: Prior to beginning work, measure the Invert of the existing grease trap. Verify the Great Basin GB -25 invert will work. Please include rework of sanitary waste piping if the invert does not work. 1. Saw cut and remove concrete slab approx 3 ft X 6 ft. 2. Open trench approx 3 ft. deep. 3. Remove existing grease interceptor and install a new Schier, Great Basin model GB -25, 3" connection, fumished by Target and installed by the contractor. a. Coordinate riser height options based on distance of grease interceptor from furthest fixture. 4. Connect inlet and outlet of grease interceptor to existing sanitary sewer lines, verifying prior to installation the width of the new interceptor will fit next to existing sanitary sewer pipes. 5. Hydro jet existing line. 6. Test for proper operation. 7. Patch existing concrete floor with compressive strength f,= 3000 psi, floor mix, max WIC = 0.55, 3-4" slump. 8. Patch floor tile to match. Ceramic Tile provided by Target Procurement. Grout, mastic, underlayment, etc. provided by Contractor. 9. Clean-up and dust control per food safety standards. 10. All work to be performed after store hours. 11. Per archived drawings available, existing floor tile is a. Contractor shall verify the quantity and match is acceptable prior to install. Attachments - Existing under floor plumbing plan New under floor plumbing plan Great Basin GB -25 cut sheet Great Basin Request for Approval REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013 City of Tukwila BUILDING DIVISION END OF SCOPE OF WORK RECEIVFr SEP. 17 2013 TUKVviL„ PUBLIC WORKS RECEIVED CITY OF TUKWILA SEP 1 3 2013 PERMIT CENTER 1 of 1 O:\Special_Proj ects\BCT# 172188- 2013_Greasetrap_Replacement\0627_WA_SouthCenter\_ActiveCAD\T0627_SouthCenter_ WA GI Int SOW.docx F(i1r- \vg REVISIONS Nc changes shall be made to the scope of work Vthout prior approval of Tukwita Building Division. I NcilTE: Revisions will require a new plan submit,' 1 ar d may include additional plan review fccs. - --ij SEPAR)TE PERMIT REQUIRE.D FOR: VISI- Mechanical gElectrical, F lumbing Gas, Piping My of Tukwila DIVISION 13. ' EXISTING FOOD SERVICE UNDERFLOOR PLUMBING PLAN CO 0 Perr Plan review Approval of th'p violator 'If approved By FILE COPY nitNo. approval is subject to errors and omissions. construction documents does not authoilze of any adopted code or ordnance. Receipt Field Copy and conditions is acknowledged: /(X. REVIEWED FOR :CODE COMPLIANCE APPROVEI? -SEP 2 3 2013 City oil - BUILDING D - 'O-; .4. 4 St/Ao-\ ex* k\,M&ctipe\ , \JtAYJsb atAd peAr, A vek e_CC I I ' i i ; ; • I- ; ..•-•T:" ',7,---7 i ' .; , ! I r, . ..._. 0 GREASE TRAP JOSAM MODEL 60145 FLUSH WITH FLOOR - 20 GPM FLOW RATE - 40 LB. GREASE CAP. r THREADED CONNECTION /0 City Of Tukwila BUILDING DIVISION RECENTIFTI SEP. 1 7 2013 TUNA PUBLIC WORKS - RECEIVED CITY OF TUKWILA SEP 1 3 2013 PERMIT CENTER 1761S -12_4g REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 3 2013, City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 3 2013 PERMIT CENTER SPECIFICATIONS (GB -25) 1. 3" inlet/outlets Sch. 40. (No -Hub) 2. Max flow rate: 25 GPM 3. Liquid capacity: 22 Gallons 4. Max grease capacity: 75 lbs. (10.4 Gallons) 5. Max solids/sediment capacity: 2 Gallons 6. Unit weight w/std. covers: 31 lbs. 7. Standard bolted, gasketed, gas/water tight composite covers handle 450 lbs. when unit is directly buried and a 2,500 lbs. load when buried in SR16 riser. 8. Maximum operating temperature 190°F continuous. NOTES 1. Listed by IAPMO to ASME grease interceptor standard #A112.14.3 2. Factory installed Built -In Flow control. 3. For gravity drainage applications only. Do not use for pressure applications. 4. 3/8" thick seamless high density polyethylene walls. 5. Riser is also available for burial. 6. Cover placement allows full access to tank for proper maintenance. 7. Vent not required unless per local code. 8. Engineered inlet and outlet diffusers are removabl to inspect/clean piping. 9. For on -the -floor or buried applications. 10. Integral Air Relief / Anti -siphon. 11. Three outlet options for easy rough in. Unit shipped with outlet diffuser in outlet "B". DIFFUSION FLOW TECHNOLOGY The inlet diffuser splits incoming effluent into two paths that utilize the entire liquid volume of the tank for efficient grease separation. The calibrated openings greatly reduce effluent turbulence. The effluent enters the main chamber without disturbing the existing grease or sediment layers. 27" Outlet "A" (Optional) 21" REVIEVVEL) rOR CODE COMPLIANCE APPROVED SEP 2 3 2013 A City of Tukwila BUILDINGf ? II N inlet and outlet The integral air relief/anti-siphon in the top of the outlet diffuser allows pressure stabilization within the unit during operation. The bottom of the outlet diffuser allows only effluent which is free of grease to exit the tank. It can easily be attached to any of the three outlets provided to ease jobsite piping layouts. ENGINEER SPECIFICATION GUIDE Schier Great Basin TM grease interceptor model # shall be lifetime guaranteed and made in USA of seamless, rotationally - molded High Density Polyethylene with minimum 3/8" uniform wall thickness. Interceptor shall be furnished for above or below grade installation. Interceptor shall be built in accordance to ASME A112.14.3 (type C), with field adjustable riser system, built-in flow control, built-in test caps and three outlet options. Interceptor flow rate shall be GPM. Interceptor grease capacity shall be lbs. Cover shall provide water/gas-tight seal and have minimum 2,000 lbs load capacity. OPTIONS: • Teleglide field adjustable risers for extending covers to grade • Male pipe thread connections • 2" Plain end pipe or male pipe thread connections • Clamping collar kit greose nil 6eporMars solids chemical Interceptors waste tanks process systems PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF SCHIER PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF SCHIER PRODUCTS IS PROHIBITED. 15" 4-1/4" 10-3/4" Outlet "C" (Optional) TOP VIEW 0 16" Cover Static water line 6-1/4" A Outlet "B" (Standard) i 9" invert Engineered inlet and outlet diffuser (see discription) SECTION "A -A" PART NUMBER: GB -25 Deep structural reinforcing columns ISOMETRIC VIEW 21" END VIEW Visa SPECIFICATION SHEET DESCRIPTION: GREAT BASIN SERIES POLYETHYLENE GREASE INTERCEPTOR 25 GPM, 22 LIQUID GALLONS, 75 GREASE POUNDS CAPACITY DWG BY: TEU DATE: 10/17/11 REV: 0 MATL: PE Schier Products 9500 Woodend Road Edwardsville, KS 66111 Tel: 800-827-7119 Fax: 800-827-9664 www.schierproducts.com Made in the U.S.A SCHIER PRODUCTS Pioneering Drain Line Purity RECEIVED CITY OF TUKWILA SEP 1 3 2013 PERMIT CENTER 3/3/2014 City of Tukwila Department of Community Development ERIC DIXON 124 SW 156 ST, STE 204 BURIEN, WA 98166 RE: Permit No. PG13-128 TARGET 301 STRANDER BL Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director New Inspection Request Line 206 438-9350 .In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/13/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/13/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall t Technician File No: PG 13-128 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ' PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-128 PROJECT NAME: TARGET DATE: 09/16/13 SITE ADDRESS: 301 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division TS C 0711Vir5 Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete IA Incomplete DUE DATE: 09/17/13 Not Applicable Comments: `Permit Ce'nte'r Use Only' ,-=:- INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route �+ REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 10/15/13 Not Approved (attach comments) ❑ DATE: :n..F Etr. Permit Center_Use.Only' CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: 1 Joanna Spencer From: Todd Reedy Sent: Tuesday, September 17, 2013 12:42 PM To: Joanna Spencer Subject: RE: Target @ 301 Strander Blvd PG13-128 Hi Joanna, Target @ 301 Strander is current on backflow preventer installation and testing. Have a good day, Todd From: Joanna Spencer Sent: Tuesday, September 17, 2013 9:38 AM To: Todd Reedy Cc: Han Kirkland Subject: Target @ 301 Strander Blvd PG13-128 Good Morning Todd, Are they current on their backflows ? Joanna