Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG13-140 - CHIPOTLE - ALTERATION
CHIPOTLE MEXICAN GRILL 2600 SOUTHCENTER MALL FC -02 PG13-140 • City of Tukwila Department of Community Development 0 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 190E Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: PLUMBING/GAS PIPING PERMIT 9202470010 2600 SOUTHCENTER MALL Project Name: CHIPOTLE MEXICAN GRILL Permit Number: PG13-140 Issue Date: 1/6/2014 Permit Expires On: 7/5/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 ANDY PAROLINE 3617 SW CHARLESTOWN ST, SEATTLE, WA, 98126 WESTERN CONSTRUCTION SERVS INC 4612 NE MINNEHAHA , VANCOUVER, WA, 98661 WESTECS162R8 Expiration Date: 9/16/2015 Phone: (206) 719-0339 Phone: (360) 699-5317 DESCRIPTION OF WORK: SUBTYPE: NRES STATUS: PENDING DESCRIPTION: PLUMBING AND GAS PIPING FOR RESTAURANT REMODEL. NEW WASTE VENT, FLOOR DRAINS, SINKS, WATER HEATER, ETC PER PLAN. Valuation of Work: $8,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $398.38 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Vfr"r4 Date: 6/ (D6 7/(-/ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or lo, al I - re:ulating construction or the performance of work. I am authorized to sign and obtain this developme ' '- mit an agree to the conditions attached to this permit. Sig �'R"'_ � \ Date: 1—Z1.-1/ Print Name: 010 6-11-0J This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures and fittings in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency and Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments. 13: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL • • 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKi.A Community Develop !. t Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwiIaW A. goy Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: ID y \ (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted,through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: q2'.0 Z4 oo 1 0 Site Address: `'L 6 b So ,.,-r611Com. A,i— Tenant Name: C4.1Qo-ruz A404.ILA- e._ `i t PROPERTY OWNER Name: rryiv Il�L I? -t . Name: �4, nl5 - )r,l � J ty►1 � COri4- f w��' � � , Address: 2 $40 5-d vl'u ()Y- 4. /H.1 City: Ste, State: 1M4. Zip: fs,A CONTACT PERSON — person receiving all project communication Name: rryiv Il�L I? -t . Address: 3� f 1 Si Gil a fL&sTow' S -1- City: City: /' o rr State Zip: g2st,i, Phone: ax: Iv( ' '-}-lit. Email li t,s4 a m... t., )ce f.rio c t n. re$ . c.v✓, Suite Number:P ..'Z Floor: New Tenant: Yes ❑.. No PLUMBING CONTRACTOR INFORMATION Company Name: r - Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: 6t Valuation of Project (contractor's bid price): $ 101 000. Scope of Work (please provide detailed information): 7(..-v✓4i,, (1 ( �1,4-s ? gf'L 5 t -Adel , IA) IA. 11 f-r�' 1rt;.1^"i .f Loo�ti D11.I�6/I5 C 1 k4-5 t31 -c-- 7 7 L,q.h. Building Use (per Int'1 Building Code): Occupancy (per Int'l Building Code): �r� Utility Purveyor: Water: _ 11A V W t �1 H:\Applications'Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Sewer: W t Ogk Page 1 of 2 Indicate type of plumbing fixtures and/or as piping outlets being installed and the quanti Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 7. - Shower, single head trap Sinks be Rain water system - per drain (inside building) l Grease interceptor for commercial kitchen (>750 gallon capacity) • - \ • Each additional medical gas inlets/outlets greater than 5 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow ` •protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 7. - Lavatory Urinal Water heater and/or vent l Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric- type vacuum breakers 2 inch (51 mm) diameter or smaller 1 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 ` • Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 7. - Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 'Backflow protective device other than atmospheric -type - vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets ` Fixture Type I Qty Dental unit, cuspidor Floor drain 7. - Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension .shall 'be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR Signature: D AGENT: Print Name: Day Telephone: Date: A/3 -1-a$6 • z/5 . oJ3cl Mailing Address: 3�%� Sg/ 4/2. LAS -C&-'f' S� Cg2411- city H: \ApplicationsTorms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $318.70 PG13-140 Address: 2600 SOUTHCENTER MALL Apn: 9202470010 $318.70 GAS $65.00 PERMIT FEE R000.322.100.00.00 $65.00 PLUMBING $253.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 EA SUPPLEMENTAL PERMIT R000.322.100.00.00 $16.55 PERMIT FEE TOTAL FEES PAID BY RECEIPT: R606 R000.322.100.00.00 $204.65 $318.70 Date Paid: Monday, January 06, 2014 Paid By: JOHN F GAIN Pay Method: CREDIT CARD 005380 Printed: Monday, January 06, 2014 12:09 PM 1 of 1 CRWSYSTEMS SET RECEIPT RECEIPT NO: R13-02869 Initials: JEM Payment Date: 10/11/2013 User ID: 1165 Total Payment: 930.09 Payee: ANDREW P PAROLINE, APP VENTURES SET ID: S000002091 SET NAME: CHIPOTLE SET TRANSACTIONS: Set Member Amount D13-319 673.56 EL13-0995 76.80 M13-190 100.05 PG13-140 79.68 TOTAL: 47.3--513' TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 930.09 TOTAL: 930.09 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 76.80 000.345.830 853.29 TOTAL: 930.09 INSPECTION RECORD Retain a copy with permit P613-r`fa INSPECTION NO. PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 CITY OF TUKWILA BUILDING DIVISION Permit Inspection Request Line (206) 431-2451 Project: PO iLL Type ¢>:In`�tg � Addddress: ;..6ov Mkr Date Called: Special Instructions: Dateento (�-! / �-- ! 112 p.m. Requester:_ Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: s i 'el Nk ; f C nl(f‘ /17-s (ELIC -- Insp tor n ' El SPECTION FEE REQUIRE . Prior to next inspection, fee must be 'd at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dade j 7-/y -/ P6(3 -144) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:\Type knspection: Add {S7s:t/' /� '` SC , ii1 /n} 1/ h Date -al/l�e l:: l Special Instructions: I Date Wanted: !�, . 7--- . — L� /� p.m. Requester: 1 Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: . 6 -s,,u.,f--( /L,, r� V fe,l) U 6 t -4 /I°1 J /Lf; . & &s ,2D u6 H- ±'N 0 {� D/ 0k (vi l ( ii-e,a M.e AX 1 N -4 . S D P cr S s yA,.. /Z__ ,/ '? '' ��I 1 c( Inspect • r: Date ( C� REINSPECTION FEE REQOIR D Prior to next inspection, fee must be paid at 6300 Southcenter Blv .. Suite 100. Call to schedule reinspection. INSPECTION RECORD, Retain a copy with permit INSPECTION NO. PERMIT NO. j CITY OF TU.KWILA BUILDING DIVISION /V 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proje t:. t i c` 'P,)71 -le Ju cr.:1P1k Type f Inspection: : .: f , & AL. Address: 'L(00.0 3 L- AA -1( Date Called: .. 4 . (r)A-S ► A! - Special Instructions: ' J `...:-g Date Wanted: 4 ..- (r .(G /'�. 4433- - p.m. Requester: Phone No: 3o... 6-7 -233. Q Approved per "applicable codes.: orrections required prior to approval. COMMENTS: t(-' -► ' IV A-ck Vit, LA) Mvf t -L -T ice/? L=A- A-1pp eAJe(S )r1/er C /It 1 7 e 14-1 Je r Inspector: Date • REINSPECTION FEE RE IRE . Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I' -- 7 /-i r J L rJ b c) 1,'-i OF G 4_1- INSPECTION RECORD Retain..a copy with permit INSPECTION NO. .. PERMIT NO. P6(344P CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ‘ l , pQ / )4((r J% Typh of_ Inspection: (.-c)v(-,1 -1- J &D'i"f Address: / Date Called: .. Special Instructions:. Date Wanted••,..,.6r l Requester: Phone No: qr. / LO 7767 O Approved per applicable codes.. LJ Corrections required prior to approval. COMMENTS: 3,oes:J �C I,tl A-4 z.0(0,1,- /k(2 3 . -PrdpS 1 �� Insp(ctor: Date REINSPECTION FEE REQ UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter,Blvd. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION c" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • (206) 431-3670' Permit Inspection Request Line (206) 431-2451 PGI3-coo Project: N • P obi 6f (( Typg of Inspection: iso J Col -f- .J .:&04 -S Address: 7(00 0 .Sc AAM j Date Called: .--- Special Instructions: Date Wanted• 2 -/ ` f ..a.m., p.m. Requestgrti [. Phone No 27 t r 7 O ElApproved per applicable codes. L- J Corrections required prior to approval. COMMENTS: Inspe or: Date: e'-3, 14 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION• RECORD. Retain a copy with permit INSPECTION NO. • PERMIT NO. -CITY OF TUKWILA BUILDING .DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pr9j ct:. C.1-11\ t C, .f Type of Inspection: RG U.%H ---11 Imo% - . G A %- Address: - (e00 Cl "4 Lt, Date Called: Special Instructions: 67--.l Date Wanted:. - a m. Requester: Phone No: Z55 9-0 -7(..77 O Approved per applicable codes.. D Corrections required prior to approval. COMMENTS: 'IQ t A%.1 I�ispector: Dae: n REI TION FEE REQUIRLp. Priorto nlxt inspection, fee must be pais - 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Q6 13- ►4 O PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: C (-lIPOTLE Type of�pe�c� i n:� � C� ', Address: a(000 S,C, ntAil Date Called: Special Instructions: Date Wanted:. a_} 3_ J(.' a.m. p.m. Requester: Phone No: ['Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: OJt1 1 Da. EI PECTION FEE REQUI' ED. Prior to ext inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 \13.,(40 Project: l . Tyke_ of In pectio,�n`: — (`I Add r4:�� ,-?x.---1...� a1.) 06 SCS, Om t te Called: Day Special Instructions: ,.... Date Wanted: a.m. Requester: Phone No: ^� 34:,(4)--,9 7.Zk3'? EJApproved per applicable codes. E Corrections required prior to approval. COMMENTS: � I Date: C REINSPECTION FEE REQUIRE. Prior to next inspection. fe/must be \ paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION. RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA -98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 1)6 ti 4a. Project: j Type of Inspection: Address: /1 2(opo .S M4(1 Date Called: Special Instructions: % v ti// Date Wanted: 2-f O e" /a.m. p.m. Requester: A Phone No: ?o m -977 —2--(e3 pproved per applicable codes. l..J Corrections required prior to approval. COMMENTS: vJar �1 Inlpector: /E." Date: REINSPECTION FEE RE UIR . Prior to next inspection. fee must be: paid at 6300 Southcenterl .. Suite 100. Call to schedule reinspection. INSPECTION NO INSPECTION RECORD Retain. a. copy with permit PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ." .� d . Pi I P ((' 1(: Type of Inspection: J �t)I I. Address: 2 no S Al I Date Called: Special Instructions:. V- Date Wanted: 2 -6 i am %--) 4 . p.m. Requester: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1 Dat (� REINSPECTION FEE tEQUIRED. Prior to nextinspection, fee must be paid at 6300 Southcenfer-Bty .., Suite 100. Call to schedule reinspection. ;� jPERMIT COORD COPY i' PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-140 DATE: 10/11/13 PROJECT NAME: CHIPOTLE MEXICAN GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -2 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Q Oirt Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/15/13 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: lcPlease Route REVIEWER'S INITIALS: DATE: Structural Review Required n No further Review Required n APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 11/12/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: WESTERN CONSTRUCTION SR`S INC Washington State Department of .) Labor & Industries Page 1 of 2 WESTERN CONSTRUCTION SRVCS INC Owner or tradesperson ANDREWS, KENNETH LLOYD Principals ANDREWS, KENNETH LLOYD VICKI ANDREWS RONALD EDWARDS RONALD EDWARDS JODIE HURD-EDWARDS PATRICIA EDWARDS ROBERT EDWARDS Doing business as WESTERN CONSTRUCTION SRVCS INC WA UBI No. 600 602 277 2300 E THIRD LOOP STE 110 VANCOUVER, WA98661 360-699-5317 CLARK, County Business type Corporation Governing persons JODIEEDWARDS License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WESTECS162R8 Effective — expiration 12/28/1984 — 09/16/2015 Bond OLD REPUBLIC SURETY Bond account no. YLI261784 Received by L&I 09/11/2006 Active. Meets current requirements. $12,000.00 Effective date 09/23/2006 httos://secure.lni.wa. aov/verify/Detail.aspx?UBI=600602277&LIC=WESTECS 162R8&SAW= 01/06/2014 (BFP-1) ABBREVIATIONS AFF AFG FCO FD FS GOO ABOVE FINISHED FLOOR ABOVE FINISHED GRADE FLOOR CLEANOUT FLOOR DRAIN FLOOR SINK GRADE CLEANOUT CONNECTED GAS LOAD FIXTURE TAG LOAD [MBH] EQUIVALENT LENGTH FROM METER [FT] RICE COOKER RC -1 35 320 FRYER FB -1 95 370 GRIDDLE GR -1 107 375 RANGE RN -1 66 375 1._ MAKEUP AIR UNIT MAU-1 100 345 WATER HEATER DWH-1 150 330 TOTAL 553 MAX: 375 NOTES: 1. PRESSURE REQUIRED AFTER METER: 7" W.C. 2. DISTANCES ARE APPROXIMATE DWH-1 (RH- THROUGH ROOF 1 /2" TO BAG — F 1_F- 4-7IN-BOX 01 TO ICE LT 7 F 7MACHINE EXISTING 2 GAS PLUMBING SYMBOLS 0 ELBOW UP ELBOW DOWN DOMESTIC COLD WATER —a? DOMESTIC FILTERED COLD WATER —e DOMESTIC HOT WATER (1 10 DEGREES) �- - - - —e DOMESTIC HOT WATER RECIRC. c Z GAS ---cGAS (ON ROOF) ® PLAN NOTE: SEE PLAN NOTES LISTED ON THE SAME SHEET FOR NOTE MEANING CONNECT TO EXISTING P771 REDUCED PRESSURE ZONE BACKFLOW PREVENTER THROUGH ROOFtL 1 /2" I I— --i — I 1 22 N N N (MB-) (HB -1) wM WATER METER GAS METER EQUIPMENT TAG: SEE EQUIPMENT. SCHEDULE ON SHEET P200 FOR EQUIPMENT INFORMATION VALVE SOLENOID -OPERATED VALVE WALL HYDRANT/ROOF HYDRANT CHECK VALVE CIRCUIT -SETTER BALANCE VALVE RATED FOR POTABLE WATER " -1/2" 1-114" DWH-1 (FB -1) (GR -1) 1" (HB -1) } (SK -11] (RN -1) REVISIONS No changes shaft be made to the scope of work without prior approval of Tukwila Building Division. NOTE: revisions will require a new plan submittal and may include additional plan review fees. 1" N�— 2 2 NI NI } �HS-2) I TO RETHERMS 3/4" 3Z4" (BFP-3) 1/2" (SK -2) (HB -2) NINA PLUMBING GENERAL NOTES A, GENERAL NOTES APPLY TO PLUMBING SHEETS. B. PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE PLUMBING CODE, LOCAL HEALTH DEPARTMENT STANDARDS, AND THE AUTHORITY HAVING JURISDICTION. SEE SHEET A000 FOR THE PREVAILING CODES. C. PIPING LAYOUTS ON DRAWINGS ARE SCHEMATIC. EXACT LOCATIONS ARE TO BE COORDINATED WITH THE EXISTING CONDITIONS AND THE WORK OF OTHER TRADES. D. CONCEAL PIPING UNLESS NOTED OTHERWISE. WATER SUPPLY PIPES SHALL BE INSTALLED LEVEL. E. PROVIDE STOP VALVES AT FIXTURES, F. PROVIDE SHUT-OFF VALVES FOR ISOLATION OF FIXTURE GROUPS AS SHOWN ON DRAWINGS IN ADDITION TO STOP VALVES AT EACH FIXTURE. G. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. H. PIPING IN EXTERIOR WALLS SHALL BE INSTALLED BETWEEN THE INSULATION AND THE INTERIOR WALL FINISHING MATERIAL. I. PROVIDE GAS SHUT-OFF VALVES AT EACH PIECE OF EQUIPMENT. PROVIDE ACCESSIBLE DIRT LEG AT THE BOTTOM OF VERTICAL SECTIONS OF GAS PIPE AND AT THE CONNECTION TO EACH PIECE OF EQUIPMENT, J. INSULATE THE HOT AND COLD WATER, CONDENSATE DRAINAGE, AND STORM PIPING PER THE SPECIFICATIONS AND DETAIL 6/P300. K. WHERE THE WATER OR GAS SUPPLY LINE SIZE SHOWN IN THE PLUMBING DIAGRAMS DIFFERS FROM THE FIXTURE OR EQUIPMENT CONNECTION SIZE, PROVIDE LINE SIZE PIPE TO WITHIN 6" OF THE FIXTURE OR EQUIPMENT BEFORE TRANSITIONING TO THE CONNECTION SIZE. MATERIAL SCHEDULE CATEGORY APPLICATION ALLOWABLE MATERIAL NATER SUPPLY PIPE ABOVE GRADE TYPE L COPPER TUBE NATURAL GAS PIPE CONCEALED STEEL PIPE, MALLEABLE IRON THREADED FITTINGS EXPOSED STEEL PIPE, MALLEABLE IRON THREADED FITTINGS, PAINTED WATER INLET PORT NOZZLE AIR GAP EDUCTOR VENTURI PROPORTIONER PRODUCT FEED PRODUCT PICK-UP INLET DISCHARGE TUBE REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 4 2013 Ar City o BUILDIN kwila IVISION ® PLAN NOTES 1. CONNECT TO THE EXISTING 2" DOMESTIC WATER SERVICE LINE IN THE CORRIDOR, 2. PROVIDE 1/2" DOMESTIC WATER SERVICE TO THE BAG -IN -BOX SODA DISPENSER AT 102" AFF. SODA DISPENSER SHALL HAVE AN INTEGRAL ASSE 1022 -RATED CARBONATED BEVERAGE BACKFLOW PREVENTION DEVICE. 3. PROVIDE WATER HEATER DWH-1 PER DETAIL 1/P300. 4. PROVIDE BACKFLOW PREVENTER AND WATER FILTERS MOUNTED TO WALL PER DETAIL 11/P300. PROVIDE 1/2" SUPPLY PIPES FROM FILTERS TO ICE MAKER AND SODA CARBONATOR AS SHOWN. 5. PROVIDE 1/2" FILTERED WATER TO THE ICE MAKER AT 56" AFF. 6. PROVIDE DOMESTIC WATER ROUGH -INS FOR THE MOP BASIN FAUCET AT 36" AFF. PROVIDE DOMESTIC WATER ROUGH -INS FOR THE CHEMICAL DISPENSER FAUCET (HB -1) AT 64" AFF DIRECTLY ABOVE THE MOP BASIN FAUCET. SEE ARCHITECTURAL ELEVATION FOR DETAIL, 7. CONNECT TO THE EXISTING 2" GAS LINE, 8. PROVIDE GAS CONNECTIONS TO THE COOKING EQUIPMENT PER DETAIL 2/P300. 9. SUPPORT THE GAS PIPE ON THE ROOF PER DETAIL 5/P300. WOOD BLOCKING IS NOT AN ACCEPTABLE METHOD OF SUPPORTING THE GAS PIPE, 10. PROVIDE ACCESSIBLE LINE -SIZED GAS VALVE, DIRT LEG, AND UNION AT GAS CONNECTION TO THE EQUIPMENT. 11. PAINT INTERIOR AND EXTERIOR EXPOSED GAS PIPING WITH ZINC CHROMATE PRIMER AND ONE FINAL COAT OF EXTERIOR ENAMEL. FINAL COLOR SHALL MATCH SURROUNDING FINISHES 12, PROVIDE DOMESTIC WATER ROUGH -INS FOR THE CHEMICAL DISPENSER FAUCET (HB -1) AT 52" AFF. SEE ARCHITECTURAL ELEVATION FOR DETAIL. 13. PROVIDE DOMESTIC WATER ROUGH -INS FOR THE VICTORY WASH DISPENSER FAUCET (HB -2) AT 52" AFF, SEE ARCHITECTURAL ELEVATION FOR DETAIL, 14. PROVIDE KITCHEN EQUIPMENT GAS SHUTOFF BELOW THE CEILING PER DETAIL 10/P300. PIPING AND VALVES SHALL NOT BE INSTALLED LOWER THAN 7'-6". 15. CONNECT CHEMICAL DISPENSER TO HB -1. CHEMICAL DISPENSER HAS AN INTEGRAL AIR GAP AS IS SHOWN IN DETAIL 4/THIS SHEET, 16, PROVIDE 1/2" HOT WATER TO RETHERMALIZER FILL PORTS PER DETAIL 12/P300, 17, PROVIDE ASSE 1016/1070 POINT -OF -USE THERMOSTATIC MIXING VALVE, WATTS USG -B, ON WATER SUPPLY TO HAND SINK. PROVIDE ANGLE STOP BELOW SINK, FASTEN MIXING VALVE TO WALL, AND MAKE FINAL CONNECTION FROM ANGLE STOPS TO MIXING VALVE AND FROM MIXING VALVE TO FAUCET USING BRAIDED STAINLESS STEEL HOSE. ADJUST MIXING VALVE FOR A DISCHARGE TEMPERATURE OF APPROXIMATELY 110° F. 18. PROVIDE ACCESSBLE VALVE IN WATER SUPPLY TO FIXTURE AS SHOWN. 19. PROVIDE AN ACCESSIBLE MAIN DOMESTIC WATER METER AND SHUTOFF VALVE ABOVE LAY -IN CEILING AS SHOWN. VALVE SHALL BE 12" ABOVE THE TOP OF THE LAY -IN CEILING. PERMANENTLY INSTALL THE "WATER SHUTOFF" SIGN TO THE CEILING GRID BELOW THE VALVE. 20, PROVIDE PVC SLEEVE THROUGH LAY -IN CEILING FOR ICE MAKER REFRIGERANT LINE SET PER DETAIL `:'9/SHEET P300. MAU-1 LION ROOF 11 1 (HS -3) II III I..■IiJ■I 'tlill■i11111M N FILE COPY Permit Na..1113-140 CONSULTANT: NATIONAL ENGINEERING 788 Morrison Road Columbus, Ohio 43230 Phone: (614) 751-9610 Fax: (614) 552-5240 main©nationalengineering.com Contact: Caitlin Jones (303) 532-6433 COPYRIGHT 2013 THIS DRAWING IS AN INSTRUMENT OF SERVICE, AND AS SUCH, REMAINS THE PROPERTY OF CHIPOTLE MEXICAN GRILL INC.. PERMISSION FOR USE OF THIS DOCUMENT 1S LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH CHIPOTLE MEXICAN GRILL INC.. 1401 WYNKDOP, #500 DENVER, COLORADO 80202 PHONE: (303) 595-4000 FAX: (303) 595-4014 INTERNET: WWW.CHIPOTLE.COM STORE # 2270 SOUTHCENTER MALL 2600 Sou th cen ter M Tukwila, WA 98188 Issue Record: 10.07.2013 Landlord Issue Revisions: Plan review approval 18 subject to errors and omissions. Approval of construction documents does not a1. ttr, the violation o - adopted code or ordinance, Ro„epi approv ' d y and gDlldib0i'iS IS acknowledged' SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Cl Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION, 11I II M i II IU Mil II II VB \G 1/4" = 1-0" SUP3LY FL0M Date: moi'”/V ty Oflbkwila BUILDING DIVISION RECEIVEn OCT 15 2013 TUKWll� PUBLIC WORKS RECEIVED CITY OF TUKWILA OCT 1 1 2013 LAI\ PERMIT CENTER Drawn: JAS Checked: MPC Project No, 13157 Contents: PLUMBING PLAN WATER & GAS F' 100 Date of Last Print: 10.04.2013 (FS -2) (FS -1) C.O.3" Ir3+-\ GW — C.O. w— - 4" (FD - (FS - FD - (FS -1) If -37\ —Gw N GW 1' 1' N (FS -1) (FS -1) 3,` C.O. Tr3+-\tr-3" N-Gw 4" —GW GW (FD -1) N (FD -1) 37(FS-1� (Hs -2) Irt (MB - If -27K V 17\ V - 3' EXT'G 4" MATERIAL SCHEDULE CATEGORY APPLICATION ALLOWABLE MATERIAL SANITARY WASTE & VENT PIPE ABOVE GROUND, CONCEALED PVC PLASTIC DWV PIPE AND FITTINGS ABOVE GROUND PREP SINK AND WARE WASHING SINK DRAINS PVC PLASTIC DWV PIPE AND FITTINGS ABOVE GROUND HAND SINK DRAINS BRASS WITH CHROME FINISH BELOW GROUND PVC PLASTIC DWV PIPE AND FITTINGS ® PLAN NOTES PLUMBING SYMBOLS GW CD o ELBOW UP 3 ELBOW DOWN -e SANITARY WASTE —�' GREASE WASTE - SANITARY VENT CONDENSATE DRAIN PLAN NOTE: SEE PLAN NOTES LISTED ON THE SAME SHEET FOR NOTE MEANING CONNECT TO EXISTING FLOOR DRAIN FLOOR SINK 0 CLEANOUT EQUIPMENT TAG: SEE EQUIPMENT SCHEDULE ON SHEET P200 FOR EQUIPMENT INFORMATION 0 O 1. PROVIDE 3/4" CONDENSATE DRAIN FROM THE WALK-IN COOLER EVAPORATOR TO THE FLOOR SINK, DISCHARGE THROUGH AN AIR GAP. 2. PROVIDE DRAIN CONNECTIONS TO THE FOUR COMPARTMENT SINK PER DETAIL 4/P300. 3. NOT USED. 4. PROVIDE DRAINAGE PIPES FROM THE ICE MACHINE TO THE FLOOR SINK PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE A CODE -APPROVED AIR GAP AT THE DISCHARGE TO THE FLOOR SINK, PROVIDE DRAIN LINES FROM THE FOOD PREP SINK TO THE FLOOR SINK, PROVIDE AN AIR GAP AT THE DISCHARGE TO THE FLOOR SINK. PROVIDE A 3" VENT THROUGH THE ROOF PER DETAIL 8/P300. CONNECT TO EXISTING 4" GREASE SEWER, NOT USED. 9. PROVIDE 3/4" VALVED DRAIN FROM HOT FOOD TABLE TO THE FLOOR SINK. DRAIN THROUGH AN AIR GAP. 10, PROVIDE INSULATED COPPER DRAIN LINES FROM THE TEA TRAY DRAIN AND THE SODA MACHINE DRAIN TO THE FLOOR SINK. DRAIN THROUGH AN AIR GAP. PROVIDE VALVED INDIRECT DRAIN FROM THE RETHERMALIZER DRAIN CONNECTION TO THE FLOOR SINK BELOW THE RICE COOKER TABLE. DRAIN THROUGH AN AIR GAP. HOLD INDIRECT DRAIN PIPE TIGHT TO THE WALL. 12. DO NOT PROVIDE WALL CLEANOUTS ON TILE AND PLYWOOD SURFACES. IF A WALL CLEANOUT IS REQUIRED IN A TILE SURFACE COORDINATE THE EXACT LOCATION WITH CHIPOTLE'S CONSTRUCTION MANAGER. 13. PROVIDE INDIRECT WASTE AND CONDENSATE DRAINS FROM FIXTURES OTHER THAN KITCHEN SINKS CONCEALED IN THE WALL AS SHOWN IN DETAIL 13/SHEET P300. 14. PROVIDE DURIRON FOR SANITARY BRANCH LEADING FROM SODA MACHINE. [3:3°' 0000 —17 r 1 4 ■ ■J II � B� �fl�I �G�l�l ■ 1f�ltl�ii 121-1/2„ !JlffiI[jJI 1�— REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 4 2013 City of Tukwila BUILDING DIVISION 51 3LU v J \G WASTE & VE 1/4" = 1'-0 T FLOO DLA\ ly4 RECEIVED CITY OF TUKWILA OCT 1 1 2013 PERMIT CENTER CONSULTANT: NATIONAL ENGINEER 1 N 0 788 Morrison Road Columbus, Ohio 43230 Phone: (614) 751-9610 Fax: (614) 552-5240 main©nationalengineering.com Contact: Caitlin Jones (303) 532-6433 COPYRIGHT 201 3 THIS DRAWING IS AN INSTRUMENT OF SERVICE, AND AS SUCH, REMAINS THE PROPERTY OF CHIPOTLE MEXICAN GRILL INC.. PERMISSION FOR USE OF THIS DOCUMENT IS LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH CHIPOTLE MEXICAN GRILL INC.. 1 401 WYNKO0P, #500 DENVER, COLORADO 80202 PHONE: (303) 595-4000 FAX: (303) 595-4014 INTERNET: WWW.CHIPOTLE.COM STORE # 2270 SOUTHCENTER MALL 2600 Sou th cen ter Mall U LL WA 98188 0 F— Issue Record: 10.07.2013 Landlord Issue Revisions: Drawn: Checked: CEJ MPC Project No. 13157 Contents: PLUMBING PLAN WASTE & VENT F 110 Date of Last Print: 10.04.2013 w- 1- - le. sga- - '11111' REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 4 2013 City of Tukwila BUILDING DIVISION 51 3LU v J \G WASTE & VE 1/4" = 1'-0 T FLOO DLA\ ly4 RECEIVED CITY OF TUKWILA OCT 1 1 2013 PERMIT CENTER CONSULTANT: NATIONAL ENGINEER 1 N 0 788 Morrison Road Columbus, Ohio 43230 Phone: (614) 751-9610 Fax: (614) 552-5240 main©nationalengineering.com Contact: Caitlin Jones (303) 532-6433 COPYRIGHT 201 3 THIS DRAWING IS AN INSTRUMENT OF SERVICE, AND AS SUCH, REMAINS THE PROPERTY OF CHIPOTLE MEXICAN GRILL INC.. PERMISSION FOR USE OF THIS DOCUMENT IS LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH CHIPOTLE MEXICAN GRILL INC.. 1 401 WYNKO0P, #500 DENVER, COLORADO 80202 PHONE: (303) 595-4000 FAX: (303) 595-4014 INTERNET: WWW.CHIPOTLE.COM STORE # 2270 SOUTHCENTER MALL 2600 Sou th cen ter Mall U LL WA 98188 0 F— Issue Record: 10.07.2013 Landlord Issue Revisions: Drawn: Checked: CEJ MPC Project No. 13157 Contents: PLUMBING PLAN WASTE & VENT F 110 Date of Last Print: 10.04.2013 PLUMBING FIXTURE / EQUIPMENT SCHEDULE TAG FIXTURE MANUFACTURER MODEL NUMBER DESCRIPTION - CONNECTION SIZES QUANTITY FIXTURE UNITS (EACH) FIXTURE UNITS (TOTAL) HW CW WASTE CW HW TOTAL SAN CW HW TOTAL SAN BFP-1 REDUCED PRESSURE BACKFLOW PREVENTER CONBRACO 40-203 REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER WITH AUTOMATIC DIFFERENTIAL RELIEF VALVE __ 1/2" -- 1 1 -- 1 -- 1 -- 1 -- BFP-3 DUAL CHECK VALVE BACKFLOW PREVENTER CONBRACO 40 -3X3 -3X -TC DUAL CHECK VALVE WITH THREE TEST COCKS -- 1/2" -- 1 1 -- 1 -- 1 -- 1 ET -1 EXPANSION TANK AMTROL ST -12 4.4 GALLON CAPACITY -- 3/4" -- 1 -- -- -- -- FD -1 FLOOR DRAIN WATTS FD -100 -FC METAL FLOOR DRAIN WITH 2" OUTLET, SURFACE MEMBRANE CLAMP, 7" DIAMETER NICKEL BRONZE STRAINER, AND TRAP PRIMER TAPPING __ __ 2» 3 -- _- __ 2 __ __ __ 6 FS -1 FLOOR SINK WATTS FS -760 -FC 12" ROUND X 8" DEEP CAST IRON FLOOR SINK WITH 3" OUTLET, FLANGE WITH WEEPHOLES AND FLASHING CLAMP, SECONDARY STRAINER, AND 1/2 GRATE -- -- 3"6 -- -- -- 5 -- -- -- 30 FS -2 RETHERMALIZER FLOOR SINK WATTS. FS -720 -FC 8" ROUND X 6" DEEP CAST IRON FLOOR SINK WITH 3" OUTLET, FLANGE WITH WEEPHOLES AND FLASHING CLAMP, SECONDARY STRAINER, AND 1/2 GRATE -- -- 3" 1 -- -- -- 5 -- -- -- 5 HB -1 HOSE BIBB FURNISHED BY TES -- COMMERCIAL QUALITY HOT & COLD MIXING WALL HYDRANT. SUPPLY ARMS SHALL HAVE INTEGRAL SHUT-OFF STOP AND CHECK VALVE. 1/2" 1/2" -- 2 1.5 1.5 2 -- 3 3 4 -- HB -2 HOSE BIBB FURNISHED BY TES __ SILL FAUCET WITH 1/2" NPT FEMALE INLET AND 3/4" GARDEN HOSE THREADED OUTLET. -- 1/2" -- 1 1 -- 1 -- 1 -- 1 HS -2 KITCHEN HAND SINK FURNISHED BY TES _ _ STAINLESS STEEL SINK WITH WALL MOUNTING BRACKET AND BACKSPLASH MOUNTED FAUCET WITH SWIVEL GOOSENECK 1/2" 1/2" 2" 1 1.5 1.5 2 1 1.5 1.5 2 1 HS -3 KITCHEN HAND SINK FURNISHED BY TES __ STAINLESS STEEL PREP TABLE WITH INTEGRAL PREP SINK. FURNISHED WITH SWIVEL GOOSENECK FAUCET WITH NON -SPLASH AERATOR. 1/2" 1/2" 2" 1 1.5 1.5 2 1 1.5 1.5 2 1 MB -1 MOP BASIN CREATIVE INDUSTRIES TERRAZZO PRODUCTS J MC2424-6 PROVIDE TERRAZZO 24"x24"x6" HIGH MOP BASIN (COLOR: ICE) WITH STAINLESS STEEL CAPS. CONTACT TERI GRENATO OR CAROLYN DEVIVO WITH CREATIVE INDUSTRIES TERRAZZO PRODUCTS AT (773) 235-9088 TO ORDER. INSTALL SERVICE SINK FAUCET WITH BUILT IN STOPS, VACUUM BREAKER LEVER HANDLES, AND WALL BRACE FURNISHED BY TES. 1/2" 1/2" 3" 1 2.25 2.25 3 5 2.25 2.25 3 5 P-1 RECIRCULATING PUMP TACO 003-BC4-PNP DOMESTIC HOT WATER CARTRIDGE -TYPE CIRCULATOR WITH INTEGRAL TIMER. PROVIDE WITH AQUASTAT SET AT APPROXIMATELY 100° F. 1/2" -- -- 1 RH-1 FREEZE PROOF ROOF HYDRANT HOEPTNER 2131R AUTOMATIC DRAINING, FREEZLESS WALL HYDRANT WITH ANTI -SIPHON VACUUM BREAKER HOEPTNER PRODUCTS (408) 847-7615 __ 3/4" -- 1 1 -- 1 -- 1 -- 1 -- SK -1 FOUR COMPARTMENT SINK FURNISHED BY TES __ FOUR -COMPARTMENT WARE -WASHING SINK FURNISHED WITH (1) PRE -RINSE UNIT WITH-- ADD-ON FAUCET AND (1) MIXING FAUCET WITH 12" SWING NOZZLE 1/2" 1/2" TO FS 1 3 3 4 3 3 4 -- SK -2 PREP SINK FURNISHED BY TES __ STAINLESS STEEL PREP TABLE WITH INTEGRAL PREP SINK. FURNISHED WITH "BIG FLO" FAUCET. 3/4" 3/4" TO FS 1 3 3 4 -- 3 3 4 TOTALS 18.25 14.25 23 48 REVIEWED FOR E CODE COMP APPROVED NOV 0 4 2013 City of Tukwila BUILDING DIVISION WATER HEATER SCHEDULE MARK DESCRIPTION MANUFACTURER AND MODEL NO. SUPPLIER STORAGE INPUT MBH RECOVERY WATER CONN. WEIGHT TANK DIAMETER NOTES DWH-1 GAS WATER HEATER A.O. SMITH MODEL #BTH-150 A.O. SMITH 100 GALLON 150 247 GPH © 70° RISE 1-1/2" 555 LBS. 27-3/4" DIAMETER 19 RECEIVED CITY OF TUKWILA OCT 1 1 2013 PERMIT CENTER CONSULTANT: NATIONAL ENGINEER 1 N 0 788 Morrison Road Columbus, Ohio 43230 Phone: (614) 751-9610 Fax: (614) 552-5240 main©nationalengineering.com Contact: Caitlin Jones (303) 532-6433 COPYRIGHT 201 3 THIS DRAWING IS AN INSTRUMENT OF SERVICE, AND AS SUCH, REMAINS THE PROPERTY OF CHIPOTLE MEXICAN GRILL INC.. PERMISSION FOR USE OF THIS DOCUMENT IS LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH CHIPOTLE MEXICAN GRILL INC.. 1 401 WYNKOOP, #500 DENVER, COLORADO 80202 PHONE: (303) 595-4000 FAX: (303) 595-4014 INTERNET: WWW.CHIPOTLE.COM STORE # 2270 SOUTHCENTER MALL 2600 Sou th cen ter Mall U LL Tukwila, WA 98188 Issue Record: 10.07.2013 Landlord Issue Revisions: Drawn: Checked: CEJ MPC Project No. 13157 Contents: PLUMBING SCHEDULE P 200 Date of Last Print: 10.04.2013 (BFP-1) CET -1 'I 104, 0 ROOF DECK —1 COLD 0 4O077 -7)m II U' G O FLOOR DRAIN CDWH-1, /to WATER HEATER INSTALLATION NOTES /--� RECIRC. *--‘) HOT 4 S GAS FINISHED CEILING SFINISHED FLOOR A. CLEAN INLET STRAINERS AFTER CONSTRUCTION HAS BEEN COMPLETED AND PRIOR TO TURNOVER OF THE BUILDING TO THE OWNER, B. INSTALL PIPING WITH AS FEW ELBOWS AS POSSIBLE. C. MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE MATERIALS. D. ADJUST WATER HEATER TO A SETPOINT OF 120° F. E. ROTATE WATER HEATER SO THAT ACCESS PANELS, FLUE DRAIN TRAP, AND CONTROL PANEL ARE READILY ACCESSIBLE FOR MAINTENANCE, 1 WATE EATE 9 -TA L P300 NOT TO SCALE FOUR—COMPARTMENT SINK WATER HEATER DETAIL NOTES 1. PROVIDE PROVIDE TWO 90° ELBOWS AND A SCREEN FOR THE FLUE TERMINATION THROUGH ROOF. 2 PROVIDE RECIRCULATION PUMP P-1 AS SHOWN. SUPPORT PUMP FROM WALL OR STRUCTURE ABOVE. THE PUMP SHALL BE CONTROLLED BY A TIME CLOCK SET FOR THE OCCUPIED HOURS OF THE STORE AND AN AQUASTAT INSTALLED ON THE RECIRC, PIPE UPSTREAM FROM THE PUMP. 3 PROVIDE LINE -SIZE CHECK VALVES IN COLD AND RECIRCULATION WATER PIPES AS SHOWN. 4. PROVIDE EXPANSION TANK ET -1 AS SHOWN, SUPPORT TANK FROM WALL OR STRUCTURE ABOVE. 5. PROVIDE A SCREENED AIR INTAKE WITH TWO 90° ELBOWS ABOVE THE ROOF PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 6 PROVIDE PRESSURE RELIEF VALVE. PIPE PRESSURE RELIEF VALVE TO FLOOR DRAIN. 7. INSULATE EXPOSED AND CONCEALED HOT AND COLD WATER PIPING TO WITHIN 3" OF THE WATER HEATER, 8. PROVIDE LINE—SIZE BALL VALVES IN COLD AND HOT WATER PIPES AS SHOWN. 9. IF THE COLD, HOT, OR GAS PIPE LINE SIZE AS SHOWN ON THE PLUMBING PLANS IS LARGER THAN THE WATER HEATER CONNECTION SIZES, PROVIDE REDUCERS WITHIN 6" OF THE WATER HEATER, 10. PIPE PRESSURE RELIEF VALVE DISCHARGE AND WATER HEATER CONDENSATE DRAIN TO THE FLOOR DRAIN, DRAIN THROUGH AN AIR GAP, 11. PROVIDE AN EXPOSED DRIP LEG AND LINE—SIZE GAS VALVE ON THE GAS SERVICE TO THE WATER HEATER. 12. PROVIDE A 4"0 PVC FLUE FROM WATER HEATER TO THE POINT OF DISCHARGE. 13. PROVIDE A 4"0 PVC INTAKE PIPE FROM THE WATER HEATER TO THE POINT OF INTAKE. HOLD HORIZONTAL PIPES TIGHT TO SINK BASINS MAINTAIN AN AIR GAP AT DISCHARGE TO THE FLOOR SINK 7- 2" PIPE DIAMETER SPACING SUPPORT 1/2" 6'_O" MIRO INDUSTRIES 1.5 PIPESTAND W/1.5 SPACER 3/4" — 1" 8'-0" MIRO INDUSTRIES 1.5 PIPESTAND W/1.5 SPACER 1-1/4" — 1-1/2 10'-0" MIRO INDUSTRIES 3—R-2 PIPESTAND W/3—R SPACER 2" - 3" 10'-0" MIRO INDUSTRIES 3—R-2 PIPESTAND W/3—R SPACER 1/2" SUPPLY \\._PROVIDE CLEANOUTS IN THE ENDS OF THE PIPES GREASE WASTE: SEE SHEET P110 FOR CONTINUATION 4 WA E -WAS FLOOR SINK I\G SI\ DETA L P300 NOT TO SCALE NOT TO SCALE TO D RAIN ROOF INSULATION 90° STREET ELBOW QUICK DISCONNECT SWIVEL CONNECTION 90° STREET ELBOW GAS STUBBED THRU / WALL AT 27"AFF D 0 BALL VALVE KITCHEN EQUIPMENT SWIVEL CONNECTION 6" DIRT LEG FLEXIBLE GAS LINE RESTRAINING CABLE ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT ACTUAL CONDITIONS. MAKE FINAL CONNECTION TO EQUIPMENT AS RECOMMENDED BY MANUFACTURER. PROVIDE WELDED FITTINGS/JOINTS IN ANY CONCEALED, UNSLEEVED LOCATION. SEE PLUMBING DRAWINGS FOR PIPE SIZE PROVIDE DECK PLATE COMPATIBLE WITH THE ROOFING SYSTEM PROVIDE PILLOW BLOCK PIPE STAND OF POLYCARBONATE RESIN MATERIAL (SEE SCHEDULE) <ITC E\ GAS EQ,I NOT TO SCALE 3NIE\ PILLOW BLOCK PIPE STAND DECK PLATE ROOFING MATERIAL PLAN 1 DETAIL DRAINAGE PORTS ON THE SIDES OF THE PIPE STAND BASE CENTER PIPE STAND ON DECK PLATE STRAP THE PIPE TO THE PIPE STAND ROOF DECK EXHAUST HOOD OPEN STUDS ABOVE CEILING TO VENT THE WALLCAVITY i CHROME ONE—PIECE ESCUTCHEON (TYP.) LAY—IN CEILING THE ROUTING OF THE GAS PIPE MUST COMPLY WITH LOCAL CODES AND AUTHORITIES HAVING \IJURISDICTION PROVIDE A LINE—SIZE MANUAL GAS SHUTOFF VALVE BELOW THE CEILING PROVIDE A LINE—SIZE MECHANICAL GAS VALVE BELOW THE CEILING. INTERCONNECT TO THE HOOD FIRE SUPPRESSION SYSTEM. ROUTE MAIN GAS LINE FOR UNDER HOOD EQUIPMENT IN VENTED WALL SPACE SEQUENCE OF OPERATIONS: NORMAL MODE: • WHEN HOOD FAN IS ENERGIZED SOLENOID VALVE IS TO OPEN. • ON A LOSS OF POWER OR IF THE FAN IS DE—ENERGIZED THE VALVE IS TO CLOSE. EMERGENCY MODE: • UPON ACTUATION OF THE FIRE SUPPRESSION SYSTEM OR A SIGNAL FROM THE FIRE ALARM, THE SOLENOID VALVE IS TO CLOSE STACK PIPE STANDS AND SPACERS TO SECURELY SUPPORT THE PIPE. WOOD BLOCKING OR SHIMS ARE NOT ACCEPTABLE. ELEVATION USE SPACER WHERE REQUIRED TO ELEVATE PIPING. INSTALL GAS PIPE TO ALLOW FOR EXPANSION AND CONTRACTION. PRIMER COAT AND PAINT EXTERIOR GAS PIPE, GAS PIPE ON THE ROOF SHALL BE PAINTED YELLOW AND GAS PIPE INSTALLED EXPOSED ON EXTERIOR WALLS SHOULD BE PAINTED TO MATCH THE WALL FINISH, 5 OOETOP DISI\G S PPNT P300 NOT TO SCALE CUNO BEV190 WATER FILTER 1/2" FULL PORT BALL VALVE (TYP) eiLmmIJ 7 1/2" UNION (TYP) CUNO CFS44—HT SCALE INHIBITOR 12" M NIMUM ABOVE ROOF AND EXTENDED ABOVE THE LEVEL OF THE PARAPET ROOF DECK PROVIDE SLEEVE IF REQUIRED BY ROOFING SYSTEM ANCHOR VENT PIPE TO ROOF DECK OR JOIST WITH U—BOLT AROUND PIPE AND ANGLE IRON SECURED TO THE DECK OR A JOIST 3/4" X 1/2" REDUCER 1/2" HOT WATER STUBBED THROUGH WALL AT 24" AFF THREADED HOSE END ADAPTOR I1 I I 11 -.- 411i , moms <ITCHE\ NOT TO SCALE GAS S TOES DETAIL NOT TO SCALE 1/2" TO BAG—N—BOX BACKFLOW PREVENTER ON CARBONATOR 1/2" TO ICE MAKER HOLD BACKFLOW PREVENTER, SCALE INHIBITOR, AND SHUT OFF VALVES TIGHT TO WALL 1/2" HOT WATER STUBBED THROUGH WALL AT 24" AFF 48" BRAIDED STAINLESS _IIS �IIM STEEL FLEXIBLE HOSE ""- TO CONNECTION TO RETHERMALIZER REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL—SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. FLASHING AND COUNTER FLASHING ARE TO BE COMPATIBLE WITH THE ROOFING SYSTEM. NOT TO SCALE 1/2" HOT WATER STUBBED THROUGH WALL AT 12" AFF E NOT TO SCALE WATER CO\ r MITER THE INSULATION AT TEES AND ELBOWS SO THAT THERE ARE NO GAPS AT JOINTS. PROVIDE ONE—PIECE PRE—MOULDED PVC FITTING COVERS. INSULATE VALVE BODIES, LEAVE UNIONS FREE OF INSULATIONS. PROVIDE INSULATION ON PIPES WITHIN WALLS AND CHASES r \___ TAPE JOINTS OF \\_ FIBERGLASS INSULATION PROVIDE A ONE FOOT LENGTH OF NONCOMPRESSIBLE INSULATION AT HANGERS FOR PIPE 2" AND LARGER \ECTIO\ DETAIL PROVIDE INSULATION ON INTERIOR COLD AND HOT WATER PIPING, CONDENSATE DRAIN PIPE, AND STORM PIPE. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION, INSTALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD WATER AND CONDENSATE PIPING BY MEANS OF SEALANT AND TAPE. FLAME SPREAD AND SMOKE—DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. EXPOSED WATER PIPES MUST BE INSULATED USING PREFORMED GLASS FIBER PIPE INSULATION WITH PRE—MOLDED PVC FITTING COVERS. PROVIDE UNISTRUT MOUNTED TO WALL ABOVE LAY—IN CEILING PROVIDE 3" PVC PIPE STRAPPED TO WALL AS SHOWN, SEAL THE PIPE TO THE LAY—IN CEILING PANEL. COORDINATE LOCATION AND INSTALLATION WITH LAY—IN CEILING INSTALLER. REFRIGERANT LINESET FROM ICE MAKER TO ROOF—MOUNTED REMOTE CONDENSER WALL 9 DDEI NOT TO SCALE S U LAT I O \ SETA L CONCEAL DRAIN PIPE IN WALL AS HIGH AS POSSIBLE DRAIN PIPE CONCEALED IN WALL 9„ 1" \- LAY—IN CEILING 7 -ICE MAKER CEILI\G DE\ ERATIO \ REViEVVE J OR. CODE COMPLIANCE APPROVED Nov 042013 BUILD NGof DIVISION ISION INDIRECT DRAIN PIPE (T0 BACKFLOW PREVENTER, f CONDENSATE DRAIN CONNECTION, ETC.) ESCUTCHEON (TYPICAL) PROVIDE PIPE SUPPORT ATTACHED TO THE FLOOR OR WALL AS SHOWN SETA P300 —MIN. (2) PIPE DIAMETERS ` . INDIRECT WASTE RECEPTACLE (FLOOR SINK, FLOOR DRAIN, MOP SINK, ETC.) `VG C3- ly 0 RECEIVED CITY OF TUKWILA OCT 112013 PERMIT CENTER CONSULTANT: NATIONAL ENGINEER 1 N 0 788 Morrison Road Columbus, Ohio 43230 Phone: (614) 751-9610 Fax: (614) 552-5240 main©nationalengineering.com Contact: Caitlin Jones (303) 532-6433 COPYRIGHT 201 3 THIS DRAWING IS AN INSTRUMENT OF SERVICE, AND AB SUCH, REMAINS THE PROPERTY OF CHIPOTLE MEXICAN GRILL INC.. PERMISSION FOR USE OF THIS DOCUMENT IS LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH CHIPOTLE MEXICAN GRILL INC.. 1 401 WYNKOOP, #500 DENVER, COLORADO 80202 PHONE: (303) 595-4000 FAX: (303) 595-4014 INTERNET: WWW.CHIPOTLE.COM 0 N N 0 (r) SOUTHCENTER MALL 2600 Sou th cen ter Mall N U LL Tukwila, WA 98188 Issue Record: 10.07.2013 Landlord Issue Revisions: Drawn: Checked: CEJ MPC Project No. 13157 Contents: PLUMBING DETAILS 300 Date of Last Print: 10.04.2013