HomeMy WebLinkAboutPermit S2000-023 - FASHION BUGFASHION BUG
365 STRANDER BLVD
S2000-023
FREESTANDING
SIGN
SITE INSPECTION (PLANNING)
File Na. 520
Name of Tenant: 73,-;
Sian address:
Date photo taken:
Comments:
Sign appears to conform to permit application
Sign appears different from permit application
Sian not installed as Cr (date)
Make new site visit and take photo by (date)
City of Tukwila
(206) 431-3670
Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington .98188
PERMANENT SIGN PERMIT
Status: ISSUED
Type: P-PSIGN
Category: FREE
Address: 365 STRANDER BL
Location: ANDOVER PK W
Parcel #: 262304-9064
Zoning: TUC
Permit No: S2000-023
Issued: 05/12/2000
TENANT FASHION BUG
98188
OWNER PACIFIC RETAIL TRUST
1300 14TH AVE SE #208, BELLEVUE WA 98004
PLANNER ART_PEDERSON
Phone:
Phone: 425-452-9500
***************************************************************************
Permit Description:
"FASHION BUG" FREESTANDING SIGN
Total Permit Fee: 50.00
PERMANENT SIGN:
SIGN LIGHTING: NONE
WALL SIGN - Wall Area (Sq. Ft.): .00
Wall Sign Size (Sq. Ft.): .00
Face Residential Land:
FREESTANDING SIGN - Street Frontage for Entire Lot (Ft.): 400.00
Bldg Height (Ft.): 19.00
Sign Size (Sq. Ft.): 6.67
Sign Height (Ft.): 20 (In.):
Setback (Ft.): 22.00
Number of Sign Faces: 2
**** ************************************************************
/ 2- --Gip
Planning Division Authorized Signature Date
It is the responsibility of the installer to obtain the electrical permit
and inspections from the State Electrical Department. The applicant or
installer is required to call the Building Division at (206) 431-3670
for, a final inspection.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN
180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR
ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
vicy tai 1Liavviia
Department of clipmunity Development
6300 Southcenter Boulevard, Suite 100
Tukwila, Washington 98188
206 431-3670
PERMIT N
DATE:
2--0 lee(vR-:
CITY OF TUKWILA
n rlrt 1 ( nnn
rt i r\ A i LUUU
PERMANENT SIGN PERMIT APPLICATION
Please print
Rig s / I o >v &iq .36.5 S-610,1 JriPu (i l,4
Business Name Address of Sign
I-Poa. q l l ivr h elfin. J762 41/7/904.74toy S Sei17/4 W317/
,pplicant/C ntact Address, City, Stater, Zip
eo fryA act C
:ontractor /
/74aP;2po2/ G(451yS in /., 7f?/3f�
Address, City, Stat6, Zip
Separate application required for each sign proposed
] _3 sets of plans are required, including site plan showing:
• Property lines
• Streets
• Buildings
• ocations of all existing and proposed signs
•,'Sign .elevations with area calculations and dimensions
wilding elevations (for wall signs)
re and method of illumination
One copy of valid Washington State contractor's license
$50 application fee per sign
See back of form for examples
7
✓t1W
Phone
�a6. 623- 3/0o
Phone
,,o6,-62. 3-3/6o
Phone
Is your sign a:
ra Freestanding sign 15 or more feet in height Pe -FACE C IQ Li
�❑ Pole sign with face 30 square feet or more in area
Wall sign weighing 400 pounds or more
(✓ If any of the above are true you must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
❑ Structural calculations for the design of the details
prepared by a Washington State structural engineer
SIGN DESCRIPTION
s the sign:
] Internally lit
0 Externally lit g Not lit
Does the sign face residential zones or public facilities?
] Yes ❑ No
Exposed neon tubing is not allowed within 200 feet of LDR,
ti1DR or HDR zones.
Did building go through design review?
] Yes ❑ No
ncluding this sign, how many signs will list this business?
=reestanding_ Wall
NALL SIGN:
Nhat is the wall area (length x height) where the sign will be
nounted? square feet
Nall sign size: square feet
Does wall sign weigh more than 400 pounds?
] Yes ❑ No
If the sign weighs more than 400 pounds it requires structural
review. See checklist for additional information required.
FREESTANDING SIGN:
Street frontage of the entire lot where the sign will be located:
/400 feet
Generally, only one freestanding sign Is allowed per lot.
Size of sign face: 6. 6 7 square feet
Structural review is required for pole signs with faces 30
square feet or more in area, see checklist for additional
information required.
Number of sign faces: A
Height of building: feet
Generally, signs may not be higher than the building they are
associated with.
Sign height: /4� feet inches
Structural review Is required for signs 15 feet or more In
height, see checklist for additional information required.
Distance from closest edge of sign to property lines:
ALO ' feet
Generally, signs must be set back from all property lines at
least as far as they are high.
INSPECTIONS
f the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
nspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
nstalled.
\ final inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor
Ind Industries at (206) 248-6630.
(NOTE: IF A FINAL INSPECTION HAS NOT BEEN REQUESTED WITHIN 180 DAYS OF PERMIT ISSUANCE THE PERMIT WILL EXPIRE.)
HEREBY CERTIFY that the above information furnished by mo is true and correct under penalty of perjury by law in the State of Washington, and that
he applicable requirements of the City of Tukwila Will be met.
Date 1-/-/3 CC
/7z�` �
(Signature 9�r own r or authorized agent)
.206-6 -6 23, ;
/Op
Phone
FOR OFFICE USE ONLY
Zoning:
Planning review by:
O Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No Structural review by:
O Denied 0 Approved
0 Approved with conditions
Actual time spent to review Additional charges for time over 2 hours
Comments or Conditions-
16'
•
•
Tukwila Train & Jr�'
Hobby
Sign Area
.1110,--- —I _ --w —ice
Iesti o ® t. f— .s Walt
Sign Area is calculated by constructing a polygon around
the sign using right angles.
Big Store
\
\
\
\ \
\
\
\
\\ \
\
\
\
\
\\ \
\\
\\\
—\\\
\\\
\\\
f1011TMf
Building Elevation
Wall Area is calculated by multiplying the
length and height of the tenant space.
I>
I N-3
Site Plan
.I I I I I I I 1 11 Sig" L I I I I I I Property Lines
West Valley Hwy,
I . SITEILEASING PLAN
ALL EION1 AND COM.0011N10 Ant in. 4...no010 AND
MEET 1(010 AND LOCAL tOROINO ANO ELECTRICAL CODES
EMIT METAL L0T10(0• SACKS S S0111
STSET ME101.
I10TUW7,
I. WNW
PLERA.EAAN FAC
GLASS STAND
TWO 1 12110.E REM
Ir0T11 PR
• IRrLEACONNECIOR
�/vl•REA CONOUII
-�1EOI IEN507N WVLE
TRANSFORMER DOA
1RANSFORMERSNOTOVER
5000 VOLT
1t:01 ItAR10
FS SCREW *0.000
FACE A5 NE00E0
AROMAEMlILET1En
Show applicant space and all existing & proposed signs.
UCRIIIOF 0001
tETIER
300 0 0 DOLTS
105 n O(F1E01
WALL
Wall Mount Detail
For all wall mounted signs over
400 lbs.
YA S.'TOOL-6,AM WELOCI>
"Ib PCL! A.J0ATTAoJIOo TLA
91611) W/ t/D• *SE*. B0* 1'l?
A._
(--� 171- 0 CI. 40 I'OLS
•
I!1
1' c'=
Footing Detail
For all Freestanding Signs
EXAMPLE OF REQUIRED INFORMATION
J)
****************************************************************
CITY OF TUKWILA, WA TRANSMIT
****************************************************************
TRANSMIT Number: R9800266 Amount: 50.00 04/13/00 12:39
Payment Method: CHECK Notation: HEATH SIGNS Init: AP
Permit No: 52000-023 Type: P-PSIGN PERMANENT SIGN PERMI
Parcel No: 262304-9064
Site Address: 365 STRANDER BL
Location: ANDOVER PK W
Total Fees: 50.00
This Payment 50.00 Total ALL Pmts: 50.00
Balance: .00
****************************************************************
Account Code Description Amount
000/322.100 SIGN PERMIT 50.00
3625 04/19 9717 TOTAL 100.00
i(t C'. JY1 d ci e t Al (Aid /►.l atry
011(1h F1ls r Y
T-3.
• •
PIN MOUNT LETTER LAYOUT
SCALE: 1 1/2" = 1'-0"
RECEIVED
APR 13 2000
COMMUNITY
DEVELOPMENT
1
GENERAL SPECIFICATIONS:
1/4" ALUMINUM LETTERS PAINTED PMS #186
MOUNTED TO EXISTING SURFACE USING 1/4" STUDS AND SILICONE
1/4' ALUMINUM LETTERS -
1!A• ALUM. STUD ANCHOR 3' LONG
USE SIUCONE SEALANT FOR MOUNTING
TYPICAL SECTION
NOT TO SCALE
2300
121 ulss Tons 70039
26(13 OZ3
FA 1
Pu
RECEIVED
APR 1 3 2000
COMMUNITY
DEVELOPMENT
F s5�y I
5'e`
1 9 9
2• pia, Wishrwg1
g ,. G..k 16114, L
fu vekni
5-1eudurt,A
is to/!
//`9'' W,de
HEATH)
SU*Q,d'k
Com
0-
c'6
e Move .510
Na kflikp m2"
\\ 1
I s Moc�e�� OMhlj
Ke-maJe 5,40 6 Say w
P j /# ce w 1,120) .51'qt.)
.SUMP P`le✓o-Za►v 5-90e Pkceoti
1314
S.qJ �`v geilef Buy •
t/t-o'PcT1 L, N c �i
Heath and Company 1762 Airport Way South, Seattle, WA 98134
.2-1-�..�4L..'S�_� _7(_.41 % - \..3° _SSC-
FigS110'4) 15u9