Loading...
HomeMy WebLinkAboutPermit S2000-086 - SEATTLE TELCO CREDIT UNIONTELO CREDIT UNION 200 ANDOVER PARK EAST S2000-086 BUILDING MOUNTED SIGN SITE INSPECTION (PLANNING) File No. S2000-086 Name of Tenant: Seattle Telco Credit Union Sign Address: 200 Andover Pk E Date Photo Taken: 4/19/2001 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: City of Tukwila ID (206) 431-3670 Community Development / Public Works • 6300 Southcenter Boulevard, Suite 100 • Tukwila, Washington 98188 Status: Type: Category: Address: Location: Parcel #: Zoning: TENANT OWNER PLANNER CONTRACTOR PERMANENT SIGN PERMIT ISSUED P-PSIGN WALL 200 ANDOVER PK E FACING WEST AND PARKING LOT 022310-0099 TUC Permit No: S2000-086 Issued: 10/30/2000 SEATTLE TELCO CREDIT UNION TRI -LAND CORPORATION 1325 4TH AVE SUITE #1940, SEATTLE WA 98101 ART PEDERSON IDENTITY SIGNS INC 6429 #C RAINIER DR, EVERETT WA 98203 Phone: Phone: 360 691 7344 ****:k******** :k*•*k**•***A***•k*•k***•****:k:k*:k***•k*:kk******•k*:*•k****•k**•k**•k*•k*** Permit Description: "SEATTLE TELCO COMMUNITY CREDIT UNION" Total Permit Fee: 50.00 PERMANENT SIGN: SIGN LIGHTING: INTERNAL WALL SIGN - Wall Area (Sq. Ft.): Wall Sign Size (Sq. Ft.): Face Residential Land: N 642.00 38.19 FREESTANDING SIGN - Street Frontage for Entire Lot (Ft.): .00 Bldg Height (Ft.): .00 Sign Size (Sq. Ft.): .00 Sign Height (Ft.): (In.): Setback (Ft.): .00 Number of Sign Faces: ***k".**.k* O* :k*k*k* kk s**********************k********k*****•k******* Planning Division Authorized Signature Date It is the responsibility and inspections from the installer is required to for a final inspection. of the installer to obtain the electrical permit State' Electrical Department. .The applicant or ca1l,'the Building Division at (206) 431-3670 THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. sYr;kvYtykYt'k****ak***'****yk*Yi***or„ilt**'yk�k�kyk�k<�r� *************�I ** *�c�kitYkik� * (, t7TY cw uKWIf_A, WA �**************************,,**************************,-/***f*** TRANSMIT Number: R9800376 Amount: 50.00 10/16/00 16:31 Payment Method: : CK' Nc tat i can: NEON E:L f C1R1C J rii t: AP Permit No: S2000-086 Type: P-PSI'GN PERMANEN1 SIGN PERM Parcel No: 022310-0099 Site Address: 200 ANDOVER PK E: Total Fees: 50.00 This Payment 50.00 Total ALL Pmts: 50.00 Balance: .00 **************************************************************** Account Code Description Amount. 000/322.100 SIGN PERMIT 50.00 9098 10/19 9710 TOTAL 250.00 City of TIwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 (206) 431-3670 PERMIT NO 2d4rvpr;--61 Yk. DATE: OCT 1 6 2000 PER PERMANENT SIGN PERMIT APPLICATION 5 A--rn- - - LG0 Please print - PEDIT 01•1 t 0 &) ZOO •MDoDoiE2 K sT Business Name 0 at ,n ,.-r Address of Signone Applicant/Contact Address, City, State, Zip i Phone PCGEre) W f_tOgAJO 110 S• t k) sr: 6r46siL-a 1it)%>,,98i 4 zov/4iS-4-0-0/ I mon ri Tt( 5 10 -V7 g,At /J t E� ��-• J E--n"f M- ,3(yjogl - 7314 Contractor Address, City, State, Zip 428'3 Phone CHECKLIST ❑ Separate application required for each sign proposed ❑ 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs ❑ Sign elevations with area calculations and dimensions ❑ Building elevations (for wall signs) ❑ Supporting structure and method of illumination O One copy of valid Washington State contractor's license ❑ $50 application fee per sign, or 50 cents per sq. ft., whichever is greater. See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application mustgo L i through structural review. (•! STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer 070 SIGN DESCRIPTION Is the sign: Internally lit 0 Externally lit 0 Not lit Does the sign face residential zones or public facilities? O Yes No Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Did building go through design review? ❑ Yes ,No Including this sign, how many signs will list this business? Freestanding Wall WALL SIGN: What is the w II a ea_llength x height) where t mounted? •_ 2,---- square feet (9 Wall sign size: square feet Does wall sign weigh more than 400 pounds? ❑ Yes No If the sign weighs more than 400 pounds it requires structural review. See checklist for additional information required. On will b I,2 30 FREESTANDING SIGN: Street frontage of the entire premises where the sign will be located: feet Generally, only one freestanding sign is allowed per premises. Size of sign face: square feet • Structural review Is required for pole signs with faces 30 square feet or more in area, (see checklist for additional Information required). Number of sign faces: Height of building: feet Generally, signs may not be higher than the building with which they are associated. Sign height: feet inches Structural review Is required for signs 15 feet or more in height, (see checklist for additional Information required). Distance from closest edge of sign to property lines: feet Generally, signs must be set back from all property lines a distance equal to their height. INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the rbsponsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE:-"""-- I HEREBY CERTIFY that the above information furnished by me is true and correct u der penalty of perjury by law ' ' he State of Washington, and that the applicable requirements of the City of Tukwil-.�li be met. ,/ %.,. ' Date Zoning: "nature o ^' ner or authorized agent) A FOR OFFICE USE ONLY' ocelf2 0‘-z4"/ Planning review by: 0 Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: 0 Denied 0 Approved 0 Approved with conditions Actual time spent to review Additional charges for time over 2 hours Comments or Conditions: 16' • • • FIobb' Sign Area is calculated by constructing a polygon around the'sign using right angles. 13=1• 1101NM1 Building Elevation Wall Area Is calculated by multiplying the length and height of the tenant space. -4 In Existing .-11.1 111111 I ll s►gr 11111(1 I Property Lines I. N ' ••I Wes% Valley Hwy. SITE/LEASING PLAN Ile Site Plan Show applicant space and all existing & proposed signs. ALL I.OMI AMO COY K Y111 11A11 AMD IOCAI IUALDMO AMO 111C7RR.'Al C0011 111111 MIIAI ITS /ACR! . met PIM? Y11AL Ml1Aq Ri CN• Cllq! 11Nq .:11t0°0 tM'OI Irlgltrm wnR 1.1.11111M M Illi CP$AtCICR nl14lIR/V1IAc! ,---1411/11CPglllf _ ■� ✓�/Idlll9dPl Mnl 1�1:1y . 1RNIIfo1/A1R fol 1RAMl/MYl11! Aqf OM,o Mt volt KOIIIA1q '� �o� 70111111 CCU! 11 /Clllw tglpq IACI q M11110 ARCUq IA01lI flln 1• olrtll Or1A01 (1n1n Vl1 nlolwl[DI Wall Mount Detail For all wall mounted signs over 400 lbs: •1 — -c-1 17C11.P.Ar5 W11.O4e ib Pete AIJo ATrAUJeo ib 374 J W/ VsHEX 19C+i'TfP. I%i of tui 40 rote. 17-m1 _ V4..1 '- o • —1'-6 -r "r/P. Footing Detail For all Freestanding Signs EXAMPLE OF REQUIRED INFORMATION /Big Store \ \ \\\ \ \ \ \ \\\ \\\ ..\\\ \\ \\\ \ 13=1• 1101NM1 Building Elevation Wall Area Is calculated by multiplying the length and height of the tenant space. -4 In Existing .-11.1 111111 I ll s►gr 11111(1 I Property Lines I. N ' ••I Wes% Valley Hwy. SITE/LEASING PLAN Ile Site Plan Show applicant space and all existing & proposed signs. ALL I.OMI AMO COY K Y111 11A11 AMD IOCAI IUALDMO AMO 111C7RR.'Al C0011 111111 MIIAI ITS /ACR! . met PIM? Y11AL Ml1Aq Ri CN• Cllq! 11Nq .:11t0°0 tM'OI Irlgltrm wnR 1.1.11111M M Illi CP$AtCICR nl14lIR/V1IAc! ,---1411/11CPglllf _ ■� ✓�/Idlll9dPl Mnl 1�1:1y . 1RNIIfo1/A1R fol 1RAMl/MYl11! Aqf OM,o Mt volt KOIIIA1q '� �o� 70111111 CCU! 11 /Clllw tglpq IACI q M11110 ARCUq IA01lI flln 1• olrtll Or1A01 (1n1n Vl1 nlolwl[DI Wall Mount Detail For all wall mounted signs over 400 lbs: •1 — -c-1 17C11.P.Ar5 W11.O4e ib Pete AIJo ATrAUJeo ib 374 J W/ VsHEX 19C+i'TfP. I%i of tui 40 rote. 17-m1 _ V4..1 '- o • —1'-6 -r "r/P. Footing Detail For all Freestanding Signs EXAMPLE OF REQUIRED INFORMATION 0 420 0- 9I 4uI 61-5" 1j(P)V ELITY 3M GOLD COMMUNFILM APLETTERED. ACES HAVE TRANSLUCENT ELVJ b FINAL CHANNEL LETTERS LAYOUT 131-7" 1/2° = 1'-0" Signage square footage = 3f3, i G INDIVIDUALLY MOUNTED " SEATTLE TELCO COMMUNITY CREDIT UNION" CHANNEL LETTERS ARE CONSTRUCTED OF .063 ALUMINUM BACKS & 5° DEEP RETURNS LETTERS ARE FINISHED W/ AN INDUSTRIAL METAL PRIMER COATING, COAT OF ACRYLIC POLYURETHANE ON THE INSIDE (WHITE) & OUTSIDE ( DARK BRONZE ) OF LETTERS. SEAL BACKS AND SEAMS WITH LATEX CAULK ON INSIDE OF EACH LETTER. 3/16" ACRYLIC WHITE FACES W/ SILA TRIM 1" GOLD TRIM CAP. EACH LEITER SHALL HAVE TWO (2) 1/4" DRAIN HOLES AT THE BOTTOM CENTER OF EACH LETTER. ° COMMUNITY" LETTER FACES HAVE TRANSLUCENT 3M GOLD FILM APPLIED. PLAN P AAS PROPOSED SIGNAGE • BAKER BLVD ANDOVER PARK EASY 1/128° = 1'-0° EXISTING PARKING NORTH SEATTLE TELCO CREDIT UNION LEASED SPACE 1 PROPOSED SIGN ---> 1481 SETBACK FROM STREET • CHRISTENSEN ROAD 1' BRONZE TRIM CAP 15 m.' 6500 WHITE NEON TUBE 3 /16' WHITE ACRYLIC FACE GTO - 15 WIRING FROM TRANSFORMER TO ELECTRODE VIA U.L. USTED ELECTROBIT SYSTEM IC. P. A) .069 5052 ALLOY ALUMINUM LETTER TWO 1/4' DRAIN HOLES • OCT REMOTE MOLAQTED INA CAN ♦kLOSTED DISCONNECT SWITCH TRANSFORMER - GTO SLEEVING IN V? FLEX L 5- J RETURNS SECTION ATTIAG,HMENT DETAILS 351-6" WIDE STOREFRONT Not to Scale K' NIPPLE FROM NEON TO TRANSFORMER 3/16' LAG SCREW AT 2' LONG £Vlli1c7JOE ILLI SIGNS SNAIL CREEPIY RI LLL STANDARDS 505 REAR A ILL [ABU NEON & ELECTRIC SIGN CO. 110 South (Horton S4. Seattle, WA 98143 Voice 206.405.4001 Fax 206.405.4105 Seattle Telco Credit PROJECT NAME Sharon Sanford ( 206) 382-7009 CLIENT / CONTACT 200 Andover Park (East Tukwila, WA JOB ADDRESS 8.3.2000 DESIGN DATE REVISIONS: 8.19.2000 9.20.2000 10.09.2000 M. Geyer SALES PERSON 121-00 DESIGN NUMBER See Noted SCALE N.0 DESIGNER Migir EXTERIOR ELEVATION 1/4' = 1'-0" Signage square footage = 36 19 R APPRO THIS ORIGINAL DRAWING IS SUBMITTED FOR YOUR USE IN CONJUNCTION WITH A PROJECT BEING PIANNED FOR YOU BY NESCO. THESE DRAWINGS SHALL NOT BE REPRODUCED. USED BY, OR DISCLOSED TO ANY FIRM OR CORPORATION WITHOUT THE CONSENT OF NEON B ELECTRIC SIGN COMPANY, UNTIL TRANSFERRED BY SALE. Numbe RM • .110E.WCIP 8.03'--1.31' NEON & ELECTRIC SIGN CO. Mary Geyer 110 S. Horton St. • Seattle WA 98107 (206) 405-4001 • Fax (206) 405-4105 Direct Lines (206) 285-8091 • Fax (206) 285-8189 - AREA 1.78 SQ FT r FL5eatte e co F AREA 13.97 SQ FT FCOMMUNITY AREA= 7.38 SQ FT M DIT=.0 L 6.71' 13.33' ►� TOTAL AREA= 38.19 SQ FT SCALE:1' =1'. 32a.sw a(4 P,GTUAL PA`Ti"E-!Zl.I LAYdUT DF 1PIe6POSvx) G�/�NEL L-���� S«�'' 2LX) ANDave-o_- pKY . h. %11i plumping plpeb ill Wand Jlrin nave awuau<aI IIIiYlbuvn. 3. Coordinate all junction boxes and outlet locations with Casework Contractor. All junction boxes, flexible conduits, outlet receptacles, lights and all other electrical components required for power and lighting within casework items are furnished and installed by the casework contractor. General Contractor shall review the casework shop drawings to verify the location, type and quantity of connections required for all casework items and to supply all materials, permits, and labor required to complete electrical connections to casework electrical items. 4. The Contractor shall coordinate with owner supplied security data wiring, equipment and accessories to include but not limited to: conduit and J -box locations and power requirements. • 5. The Contractor shall coordinate with owner supplied furniture systems to include but not limited to: electrical and data wiring locations, J -box locations, connections and wall mounting requirements. 6. Contractor to verify all dimensions for plumbing partitions. 7. Utility Contractor to confirm layout of walls prior to construction. SIGNAGE 1. All signage shall comply, as required with the ADA. Exterior signage to be submitted under separate cover. Z 0 iZ c 0 w NORTH TAX c w p idO cc a)w ao c a= d'C°..Op `^E_ oUc .o>. v §' N m .: N.r co NN O Z OY O 1 Lt .0 `�U�U_cC�_o "w`C:1! �L' -.4) 7dViuw 0 C bC C U N :6 N1 N v ..c VON~ N oo ay C ' IOi Ctd W i_ `O O _c 0 • O 4U. ,.. os N .rb ~ o o cd N N,yN " c NO;Ni Eu cO Ei c c 0 fg +`-, N W o sago `O- F-- a i v1 d -;--, U L G1 V — >ai 0 4+ 0 O-3 cOt0MyTOo. .+sv .74 ..7 oQ O on sO 1 ~0),a"v¢> OU c do r-. so:0 "CvOc '.RI voF— c° Ss O cLwc � v `Eai c o> cO Cooa~� caw o u, °oE , U v0 7 Cv0 c: CV 4,rcoi.w lC' 4-a) P43 ` n ca s.+ oo C) ca 0) C Z 4J m L 7^ L a, L t c0 O N O s L O ai ... N U ..... -C d a" F E.O m Za' i- w co U O E c 46 (.1•5 O 1 1- 9, (Se BUILDING PLAN - Andover Plaza VICINITY MAP SITE ADDRESS: 200 ANDOVER PARK EAST TUKWILA, WASHINGTON SCALE: I" = 60'-0" SEATTLE TELCO CREDIT UNION LEASED SPACE NORTH So�ycZAti-FR 84 1,0 SCALE: NONE cc 0 0 / 0 > 1- 0sc 0 Qa NORTH 10 11 12 13 14 15 I6 1654 REGISTERED ARCHITECT Robert C. Scenes STATE OF WASHINGTON DRAWN BY LAH CHECKED BY DATE August 9, 2000 REVISED DESIGN DEVELOPMENT TITLE s 1 •. 'go i Ti • __�.w.J1