HomeMy WebLinkAboutPermit S02-011 - SEGALE BUSINESS PARKSEGALE BUSINESS PK
1800 ANDOVER PL W
P -SIGN
502-011
• •
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
Parcel No.:
Address:
Suite No:
PERMANENT SIGN PERMIT
Permit Number:
Issue Date:
Permit Expires On:
S02-011
04/17/2002
10/17/2002
Business
Name:
Address:
Property Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
SEGALE BUS. PARK
18125 ANDOVER PARK WEST, TUKWILA WA
DPA SIGNS/ KRISTI
927 N 128TH ST.
DPA SIGNS
927 N 128TH ST
Phone: 206-362-2323
Phone:
Phone: 206-362-2323
Phone: 206 362 2323
DESCRIPTION OF WORK:
"Segale Business Park"
Fees Collected:
PERMANENT SIGN:
$50.00 Zoning: Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 10965 0 0 0
Wall Sign Size (sq. feet): 89.3 0 0 0
Sign Lighting:
Face Residential Land: N N N N
Street Frontage for Entire Lot:
Building Height (feet):
Sign Size (sq. feet):
Sign Height (feet and inches):
Setback (feet):
Number of Sign Faces:
Freestanding Sign #1
0
0
0
0' 0"
0
0
Freestanding Sign #2
0
0
0
0' 0"
0
0
Planning Division Authorized Signature: Date: /
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE
OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: Permsian
S02-011 Printed: 04-17-2002
SITE INSPECTION (PLANNING)
File No. S02-011
Name of Tenant: Segale Business Park
Sign Address: 18125 Andover Park West, Tukwila WA
Date Photo Taken: 6/19/02
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of (date)
Make new site visit and taken photo by (date)
Comments:
• •
REGISTERED AS PROVIDED BY LAW AS
CONST CONT SPECIALTY -
REGIST. # EXP. DATE
CCCI DPASI**981BU 01/31/2004
EFFECTIVE DATE 01/31/2002
D P. A SIGNS
927 N 128TH ST
SEATTLE :WA - 98133 -
r ,
Signat
1..,:, -- ..-7-,....--------___
. --)„.----...—
Issued by DEPARTMENT OF LABOR AND INDUSTRIES
RECEIVED
APR 1 1 2002
Commmiry
DF:‘ ,
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
206 431-3670
•
PERMIT NO.
171/11/0d -
PERMANENT SIGN PERMIT APPLICATION
SE 7 tus • 1 AP -4 -
Business Name
Pt 51L-,tO5/ t511
Applicant/Contact 4,
1157)
Contractor
Please print
11500 ANDoV LJ 1 1v4..9t8I�g zob. 5-75.Z�
Address of Sign Phone
927 ISI 12-8 T. SVVICt 913 (33 2oro. 3(02.7-323
Address, City, State, Zip
?1' A 51 . Lcs M
Address, City, State, Zip•
Phone
Phone
CHECKLIST
GE1
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
Sign elevations with area calculations and
dimensions
Building elevations (for wall signs)
Supporting structure and method of illumination
One copy of valid Washington State contractor's license
$50 application fee per sign, or 50 cents per sq. ft.,
whichever is greater.
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation
or watt attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding___
Did building go through design review?lEP Yes 0 No
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) where the sign will be
mounted? (square feet)
0Gl(o5 SF
i
Sign size(square feet)
'S9 .3 fir'
Does sign face residential zones or public facilites?
(Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
b
Does wall sign weigh more than 400 pounds?(Y/N)
0
tt•IG
Sign illumination (internal/extemal/none)
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set back
from all property lines a distance equal to their height.
Number of sign faces
RECEIVED
PR 1 1 2002
CORM N
EVELOPMENT
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VAUD FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and
that the apicable requirements of the City of Tukwila will be met.
4-111 r ° Z -1
Date Ignature of owner or authorized agent)
zc7fa3C.Z .-2-323
Phone
FOR OFFICE USE ONLY
Zoning:
Planning review by:
0 Denied 0 Issued ❑ Issued with conditions
Structural review required? 0 Yes ❑ No
Structural review by:
❑ Denied 0 Approved ❑ Approved with conditions
RECEIVED
APR 1 1 2002
COMMUNITY
DEVELOPMENT
19'-0"
4'-8'
2 layer logo
top icon 1/4" sintra
bottom circle 1/2" sintra with automotive
finish flush mount to signface
1
DPASIGNS
design)fabsicuio"
1/2" sintra letters with 1/2"
standoff and automotive finish
flush mount to signface
This drawing is the property of DPA Signs.
Any reproduction or duplication without the
express permission of DPA Signs is a
violation of federal copyright laws.
1/2" sintra rule line with 1/2 standoff
bent to corform to sign face flush mount
with automotive finish
1/2" sintra letters flush mount to
sign face with automotive finish
REC D E®
APR 1 1 2002
COMMUNITY
DEVELOPMENT
DWG: Sign Detail
SCALE: 1/4'=1'
ORIG:
REV:
DATE: 4-3- 2001
PROJECT : Segale Business Park
CUST: Segale
JO:
AM: CJ
DWG BY:BB
•
•
1/2" sintra cutout letters painted to match
window and door system.
All cut outs attached to alum. face flush.
1-1/2"x1-1/ 2" alum. sq. tube frame
16'-6"
L
QMZabC SS 17n1313
2'-5"
skinned with .060 alum. face painted Lt. antique
bronze.
1/4" x 5"x 52" alum. brackets with gussets
mounted to wall with (4) 1/4"x 3" lag bolts and
sign frame attaches to brackets with #12 Tec
screws.
Wall structure.
This drawing is the property of DPA Signs.
Any reproduction or duplication without the
IDPCASIGNS express permission of DPA Signs is a
design>fabrication violation of federal copyright laws.
RECEIVED
APR 1 1 2002
COMMUNITY
DEVELOPMENT
DWG: Sign Detail
SCALE: 1/4'=1'
ORIG:
REV:
DATE: 4-3- 2001
PROJECT : Segale Business Park
QJST: Segale
JO:
AM: CJ
DWG BY:BB
1
1-1/2"x1-1/ 2" alum. sq. tube frame
skinned with .060 alum. face painted Lt.
antique bronze.
1/4" x 5"x 52" alum. brackets with gussets
mounted to wall with (4) 1 /4"x 3" lag bolts
Wall structure.
#12x3" Tek screws secure frame to
bracket at top an d bottom.
This drawing is the property of DPA Signs.
Any reproduction or duplication without the
DPASIGNS express permission of DPA Signs is a
violation of federal copyright laws.
design >fabrication
FIECEtIVIED
APR 1 1 2002
ODEVE OP NT
DWG: Bracket Detail
SCALE: 1-1/2"=1-0"
ORIG:
REV:
DATE: 4-10-02
PROJECT: Segale
(UST:
JO: I AM: Chris
BY:Ken
PAGE: 1 OF 1
SIto.
c -
VICINITY MAP
NTS
40y
•
��ll)llll
ENTRANCE CANOPY
BUILDING 981
((VII((((I I I I [IIJ I I I II WI
324'-6•
0
MIM I IMM•
IIIW 1111 - UI
u
•
CO
RECEJVr
.Ii
i •"1E
CMTY
DEVELOPMENT
1
WEST (ELEVATION
1/16•=1'-0•