Loading...
HomeMy WebLinkAboutPermit S02-011 - SEGALE BUSINESS PARKSEGALE BUSINESS PK 1800 ANDOVER PL W P -SIGN 502-011 • • City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: Address: Suite No: PERMANENT SIGN PERMIT Permit Number: Issue Date: Permit Expires On: S02-011 04/17/2002 10/17/2002 Business Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: SEGALE BUS. PARK 18125 ANDOVER PARK WEST, TUKWILA WA DPA SIGNS/ KRISTI 927 N 128TH ST. DPA SIGNS 927 N 128TH ST Phone: 206-362-2323 Phone: Phone: 206-362-2323 Phone: 206 362 2323 DESCRIPTION OF WORK: "Segale Business Park" Fees Collected: PERMANENT SIGN: $50.00 Zoning: Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 10965 0 0 0 Wall Sign Size (sq. feet): 89.3 0 0 0 Sign Lighting: Face Residential Land: N N N N Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Freestanding Sign #1 0 0 0 0' 0" 0 0 Freestanding Sign #2 0 0 0 0' 0" 0 0 Planning Division Authorized Signature: Date: / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: Permsian S02-011 Printed: 04-17-2002 SITE INSPECTION (PLANNING) File No. S02-011 Name of Tenant: Segale Business Park Sign Address: 18125 Andover Park West, Tukwila WA Date Photo Taken: 6/19/02 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: • • REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY - REGIST. # EXP. DATE CCCI DPASI**981BU 01/31/2004 EFFECTIVE DATE 01/31/2002 D P. A SIGNS 927 N 128TH ST SEATTLE :WA - 98133 - r , Signat 1..,:, -- ..-7-,....--------___ . --)„.----...— Issued by DEPARTMENT OF LABOR AND INDUSTRIES RECEIVED APR 1 1 2002 Commmiry DF:‘ , • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 • PERMIT NO. 171/11/0d - PERMANENT SIGN PERMIT APPLICATION SE 7 tus • 1 AP -4 - Business Name Pt 51L-,tO5/ t511 Applicant/Contact 4, 1157) Contractor Please print 11500 ANDoV LJ 1 1v4..9t8I�g zob. 5-75.Z� Address of Sign Phone 927 ISI 12-8 T. SVVICt 913 (33 2oro. 3(02.7-323 Address, City, State, Zip ?1' A 51 . Lcs M Address, City, State, Zip• Phone Phone CHECKLIST GE1 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $50 application fee per sign, or 50 cents per sq. ft., whichever is greater. See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or watt attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding___ Did building go through design review?lEP Yes 0 No WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) 0Gl(o5 SF i Sign size(square feet) 'S9 .3 fir' Does sign face residential zones or public facilites? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. b Does wall sign weigh more than 400 pounds?(Y/N) 0 tt•IG Sign illumination (internal/extemal/none) FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of sign faces RECEIVED PR 1 1 2002 CORM N EVELOPMENT INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VAUD FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and correct under penalty of perjury by law in the State of Washington, and that the apicable requirements of the City of Tukwila will be met. 4-111 r ° Z -1 Date Ignature of owner or authorized agent) zc7fa3C.Z .-2-323 Phone FOR OFFICE USE ONLY Zoning: Planning review by: 0 Denied 0 Issued ❑ Issued with conditions Structural review required? 0 Yes ❑ No Structural review by: ❑ Denied 0 Approved ❑ Approved with conditions RECEIVED APR 1 1 2002 COMMUNITY DEVELOPMENT 19'-0" 4'-8' 2 layer logo top icon 1/4" sintra bottom circle 1/2" sintra with automotive finish flush mount to signface 1 DPASIGNS design)fabsicuio" 1/2" sintra letters with 1/2" standoff and automotive finish flush mount to signface This drawing is the property of DPA Signs. Any reproduction or duplication without the express permission of DPA Signs is a violation of federal copyright laws. 1/2" sintra rule line with 1/2 standoff bent to corform to sign face flush mount with automotive finish 1/2" sintra letters flush mount to sign face with automotive finish REC D E® APR 1 1 2002 COMMUNITY DEVELOPMENT DWG: Sign Detail SCALE: 1/4'=1' ORIG: REV: DATE: 4-3- 2001 PROJECT : Segale Business Park CUST: Segale JO: AM: CJ DWG BY:BB • • 1/2" sintra cutout letters painted to match window and door system. All cut outs attached to alum. face flush. 1-1/2"x1-1/ 2" alum. sq. tube frame 16'-6" L QMZabC SS 17n1313 2'-5" skinned with .060 alum. face painted Lt. antique bronze. 1/4" x 5"x 52" alum. brackets with gussets mounted to wall with (4) 1/4"x 3" lag bolts and sign frame attaches to brackets with #12 Tec screws. Wall structure. This drawing is the property of DPA Signs. Any reproduction or duplication without the IDPCASIGNS express permission of DPA Signs is a design>fabrication violation of federal copyright laws. RECEIVED APR 1 1 2002 COMMUNITY DEVELOPMENT DWG: Sign Detail SCALE: 1/4'=1' ORIG: REV: DATE: 4-3- 2001 PROJECT : Segale Business Park QJST: Segale JO: AM: CJ DWG BY:BB 1 1-1/2"x1-1/ 2" alum. sq. tube frame skinned with .060 alum. face painted Lt. antique bronze. 1/4" x 5"x 52" alum. brackets with gussets mounted to wall with (4) 1 /4"x 3" lag bolts Wall structure. #12x3" Tek screws secure frame to bracket at top an d bottom. This drawing is the property of DPA Signs. Any reproduction or duplication without the DPASIGNS express permission of DPA Signs is a violation of federal copyright laws. design >fabrication FIECEtIVIED APR 1 1 2002 ODEVE OP NT DWG: Bracket Detail SCALE: 1-1/2"=1-0" ORIG: REV: DATE: 4-10-02 PROJECT: Segale (UST: JO: I AM: Chris BY:Ken PAGE: 1 OF 1 SIto. c - VICINITY MAP NTS 40y • ��ll)llll ENTRANCE CANOPY BUILDING 981 ((VII((((I I I I [IIJ I I I II WI 324'-6• 0 MIM I IMM• IIIW 1111 - UI u • CO RECEJVr .Ii i •"1E CMTY DEVELOPMENT 1 WEST (ELEVATION 1/16•=1'-0•