HomeMy WebLinkAboutPermit S02-029 - MARRIOTT RESIDENCE INNMARRIOTT RESIDENCE INN
16201 W VALLEY HY
P -SIGN
S02-029
•
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
PERMANENT SIGN PERMIT
Parcel No.: 0005800006
Address: 16201 WEST VALLEY HY TUKW
Suite No:
Permit Number: S02-029
Issue Date: 07/05/2002
Permit Expires On: 07/05/2002
Business
Name: RESIDENCE INN
Address: 16201 WEST VALLEY HWY, TUKWILA WA
Property Owner:
Name: INNKEEPERS RI NW L.P
Address: 306 ROYAL POINCIANA WY
Contact Person:
Name: STEVE ZAMBERLIN
Address: 1255 WESTLAKE AVE N SEATTLE WA
Contractor:
Name: NATIONAL SIGN CORPORATION
Address: 1255 WESTLAKE AVENUE N.
Phone: 425-226-5500
Phone: NONE
Phone: 206-282-0700
Phone: 206-282-0700
DESCRIPTION OF WORK:
Freestanding sign 51.7 sq ft, 23' high "Marriott Residence Inn"
Fees Collected: $134.00 Zoning: TUC Sign Type:
PERMANENT SIGN:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 0 0 0 0
Wall Sign Size (sq. feet): 0 0 0 0
Sign Lighting:
Face Residential Land: N N N N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 5.69 0
Building Height (feet): .75 0
Sign Size (sq. feet): 1.7 0
Sign Height (feet and inches): 23' 0" 0' 0"
Setback (feet): 23 0
Number of Sign Faces: 2 0
Planning Division Authorized Signature:
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE
OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
dnr.• Pprmsinn
S02 -n29 Printed? 07-05-2002
• •
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
Parcel No.: 0005800006
Address: 16201 WEST VALLEY HY TUKW
Suite No:
Tenant: MARRIOTT RESIDENCE INN
PERMIT CONDITIONS
Permit Number: S02-029
Status: ISSUED
Applied Date: 06/26/2002
Issue Date: 07/05/2002
1: As a condition of this permit the pre-existing, freestanding "Marriott Residence Inn" pole sign will be removed.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work wil a compliedwith, whether specified herein or not.
The granting of this . - mit does t presume to give authority to violate or cancel the provision of any other work or local laws
regulating construe • or the pe rmance of work.
Signature: Date:
Print Name: SYEvrifiertPli
doc: Conditions
S02-029 Printed: 07-05-2002
SITE INSPECTION (PLANNING)
File No. S02-029
Name of Tenant: RESIDENCE INN
Sign Address: 16201 W VALLEY HY
Date Photo Taken: 11/13/2002
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of (date)
Make new site visit and taken photo by (date)
Comments:
+ F625-052-000 18/97)
DEPARTMENT OF LABOR AND INDUSTRIES •
LICENSED AS PROVIDED BY LAW AS
ELEC CONTR SIGN
LICENSE # ='EXP DATE
ECO4 NATIOSC031M3 07/23/2003
EFFECTIVE DATE .'07/23/1997
NATIONAL SIGN CORPORATION
1255 WESTLAKE AVE N
SEATTLE WA 98109-3531
Duach And Display CcrtificatL
RECEIVED
CITY OF TUKWILA
PERMIT CENTER
City odrukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
206 431-3670
PER•O.
RECEIVED
CITY OF TUKWILA
PERMANENT SIGN PERMIT APPLICATICIN
014/1/t►o1T /J5,%d'Ct'JItJ
Business Name
s-rE✓E Zhiprigittc ✓
Applicant/Contact
__60.64/41, 516(1
Contractor
Please print
tI (o 1 vie"( 1441417
Address of Sign
t✓fr t 5I /" Cal''
ydl Yg
Address, City, State, Zip
(Z55 1JEfl /(E "tel. A/•
Address, City, State, Zip
(w$) z2 -.5500
Phone
2-11710
671) 242--0704
Phone
CHECKLIST
0
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
Sign elevations with area calculations and
dimensions
Building elevations (for wall signs)
Supporting structure and method of illumination
One copy of valid Washington State contractor's license
$50 application fee per sign, or 50 cents per sq. ft.,
whichever is greater.
See back of form for examples
Is your sign a:.
Freestanding sign 15 or more feet in height
Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
$84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
,6 Construction details to describe the proposed foundation
or wall • - • •• - m is (see back of form for examples)
r the sign shall be prepared by a
structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding 1
Did building go through dei r61ewYes
❑ No
Wall j
WALL SIGNS: (3(5i'1i6)
#1
#2
#3
#4
Wall area (length x eight) where the sign will be
mounted? (square feet)
Sign size(square feet)
Does sign face residential zones or public facilities?
(Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
Does wall sign weigh more than 400 pounds?(Y/N)
Sign illumination (internal/external/none)
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
(,' /s. 691
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
�7 1 11
e
111 I n 1
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
6 1 Kg -Oa
'-51.7 Olt
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
u
23 —0
Distance from closest edge of sign to property lines (feet). Generally, signs must be set back
from all property lines a distance equal to their height.
23 1011
Number of sign faces
2.
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPL • TION - VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information fumi d by m: . true and correct under penalty of perjury by law in the State of Washington, and
that the applicable requirements of the City of Tukwil. ill •e
6-26-0Z
(-zI)1J2-o1ao
Date (Signat j�•f own: or authorized agent) Phone
Zoning:
I,OR OFFICE USE ONLY
Planning review by:
O Denied
O Issued
0 Issued with conditions
Structural review required?Yes 0 No
Structural review by:
O Denied
4510 7,-
❑ Approved Approved with conditions
`ReAbin,1 r pecA-TO
CSeeacr4
1—Spec ht
per,- UBC)
•
national sign corp.
•
JOB mow ge5iPtiitcl Old (ruftwitfr)
ADDRESS wef Iguiy fro)/
SHEET NO OF
CALCULATED BY
1255 Westlake Ave N . Seattle,Wa 98109
P. 206.282.0700 F. 206.285.3091 SCALE
0
3/4 -10II
DATE( -U- ° 2
} i ,
'...•....,
; ...... 1
I !
\;4:3, /•.---
't-- ; • ,.
4
t i
' „ta
t4t L
Jri1144t F-MtIPKOW
--12027 -L-41fritqltP- 4
q" 31e0 pi,e!
4-1
vg
_318 )reei_
¥44$'P 1414
row; 12•45f4.
•
;
I
tti s-reft 42,Pf
L,4,50-044-471-ki
ow • iiih-riti„ Vol (WO
-1 •
. ,
; I i : • ' t . i
1 _L t _.t T
I
1
...- (6eftert—rAtilliOitt '.. - --i --:, ---• .-- - . - -.. ---- -
4 ...........1
. t ;
, 74 • i i. __.
i 1
1 ,
•
• I
; ; , , , . •
• . ,
3t.?..1_______
,
I 0 ' CAI ‘1'1WD).-7
1 ; I 0 0 ;
t•
• •
national sign corp.
1255 Westlake Ave N Seattle,Wa 98109
P. 206.282.0700 F. 206.285.3091
--,
1 i ,
I 1 1 1 i
r
i t
1
• ' I ' •
P _
PSF
30.• 0
30- ;
; T
; 1 -
• vonetiL _
l•mm••••••
sEc.--ri----
;; ,'1. 2
,
i a 113575;1
$.0 1 10 7V-51
.
. . : r , , 1 • , ; q1.--;3-----÷ - .--;
Zqqj 1 ' •
• • t . , ' - I • . t : , a .
. ; ! I : • ' : I
- - - - - - 2- Ili i k ' • . ,
1 , i1
, Or; :::q2(' iritIc' 24 x 433) - 1,1°
--r -
,
51.7
44.4
f1
1
2-tqg Offr. Zi.16I iti I IA) 10 di .250.11411- ;
, _.
, . , .
4- I ; I I•
,
, 1 1
I , , ; , I
i t
-17-F-114P --1:111:__1-1.-WLI:14-7_10...Pittietief' (1! x
;
; I ; l•— 1
; 0 ;
.- 4-----
.....
.. . ;
, .
—- -..;
__
23.q_xr_.7.efil__I. __ 87/6_
1 ,
'
,!-- -:- 1.-1-1.0 -x_,A, x•3_ 7 - • - - - ....,• - - , - -.v.-- ... - . -- •- ---- . ..- ,I. .-.......--••--.... ___ ..... ...__ , .
' ...5'
,
1 ,
, 1
t . ! 1
,
i
• --"--"+-
' 1 411 (-1-' q•51 x 1415 ..,... ___:-._-_.1.1q_a(7 .23___.' _
, .._ _
;-:---7---i.----i--z--:-- - -- -- ---:.
, f T .
,.._ ._.__ .. _ .__ !.. ___ ___ ...__ _ _ . L_ 7_5 723 , $o _05..... ... _7_ 77. ‘_:_P_fitg_L__...
• 1 i
, !
! ,
x ' --.6if
pee , •
1 I ,
1 ! ,t
(i 1.1( ; niy#5)___1.
• ..._...:
•
_
a
•
14'1"
-v
5'-9 " 14'1"
It________:_____
(Pole Cover )
-
9
36.1STf
.063 alum. cap p.tm.
Devoe 2M56E Country Garden
3/a" recessed on
both sides
.063 aluminum
Retainers i£ filler p.tm.
PMS 209 Burgundy
3/16" White Acrysteel face
overlaid with 3630-49
Burgundy Scotched
Al graphics to be White
sho-thru
.063 alum. bottom p.tm.
Devoe 2M56E Country Garden
063 alum. support cover p.tm.
Devoe 2M56E Country Garden
*60
Section "A"0"A"
Pole cover section 3/8"-1'-0"
Elevation (RI -50P)
3/8"_1-0"
Remove at grade existing double face sign and disppoee of.
Mfg. and install one (1) standard RI -50P at 20' OA; -1
1/2" recessed on
both sides
- 4" Vent
at each end
— Disconnect Switch
10" X 10"
flush mount
Access Door
Internally illuminated
w/ 800 ma H.O. Lamps
U.L. Labels Required
Install in accordance w/
National Electrical Codes
16"
RECEIVED
CITY OF TUKWILA
JUN 2 6 2602
+r EntvitT CHER
End view
NATIONAL SIGN CORPORATION
1255 WESTLAKE AVENUE NORTH
SEATTLE, WASHINGTON 98109
• DESIGN NO. 010804-R1
DISTRIBUTION OF PRINTS
MASTER
ELECT
SHOP FILE
INS./SH IP
STK RM.
CUSTOM
PAINT
ASSEMBLY
0000❑❑❑❑
CRATE
HT. TR.
PLEX
VINYL
PATE.
CAD
CAM
NEON
00000000
TOTAL
AWN. ASSY.
AWNING
ALUMINUM
SHOP #2
CHNI. LTR
LTR. PAINT
LTR. ASSY:
ITR. PI.X.
00000000
WORN ORDER NO.
SHT. 1 of 1 DATE: 03.26.01
Chandler
Signs
r,
..,.,"
www.chandlersigns.com
3201 Manor Way 214-902-2000
Dallas, TX 75050 Fax 214-902-2044
2420 Valiant
San Antonio,
210.349-3804
TX 78216 Fax 210-349.8724
- Suite 400 281-931.9050
TX 77060 Fax 281-931.9011
16740 Hedgecroft
Houston,
2420 Vista Way - Suite 200 H 760-9677003
Oceanside, CA 92054 Fax 760-967-7033
750 E. Hwy. 24 - Bldg. 2, Suite 200 719-687-2507
Woodland Park, CO 80863 Fax 719-687-2506
CLIENT: Residence Inn
STREET:
MY/ SIAM Tukwila, WA
SALES: Bill Teel
ARTIST: PC
APPROVAL/DATE
ii ,r.
SALES:
1 u'1 i
ART:
ENGINEERING:
LANDLORD:
This drawing is the property of Chandler Signs, Inc. and a0 nghts
to its use for reproduction are reserved by Chandler Signs. Inc.
REVISION / DATE
R1- Change height of sign. 06.24.02
MATERIAL LISTS
DISTRIBUTION OF PRINTS
MASTER
ELECT
SHOP FILE
INS./SH IP
STK RM.
CUSTOM
PAINT
ASSEMBLY
0000❑❑❑❑
CRATE
HT. TR.
PLEX
VINYL
PATE.
CAD
CAM
NEON
00000000
TOTAL
AWN. ASSY.
AWNING
ALUMINUM
SHOP #2
CHNI. LTR
LTR. PAINT
LTR. ASSY:
ITR. PI.X.
00000000
•
1'-1 W
•
•
5,-9"
t';*
CAP O
TOP&
19
TLINE
BOTTOM 3/4"1
—#
VISA!!
LO
•
1'-1 3/4"
LAMPING AND FRAMING DETAILS
MFR. (1) A5 SHOWN
(1) 120v, 20a CIRCUIT(5) REQ'D
INSTALL PRIMARY(IES) PER N.E.C.
U.L. LABELS REQUIRED
INSTALL SIGNAGE PER N.E.C.
NATIONAI SIGN CORPORATION
1255 WESTIAKEAVENUE NORTH
SEATTLE, WASHINGTON 98109
MB
tit
3/4'_1'-0"
• ' DESIGN NO. 010804 - (in engr.temp.
ROLLED 1 W' x 1 Ya" x .125" ALUM. 50. TUBE
FRAME (16" WIDE)
.063" ALUM. FILLER -VARIOUS DEPTHS
with1BUILT IN RETAINER -SEE DETAIL
1 r/a",x 1 W' x .125" ALUM. 50. TUBE FRAME (16" WIDE)
AE -82/83 ALUM. RACEWAY FOR BALLAST
AND LAMPING POSITIONS
800MA ILLUMINATION with (4)F48 LAMPS,
(2)F60 LAMPS, (2)F64 LAMPS, AND
(2)256-472 BALLAST @ 2.7 AMPS EA.
5.4 AMPS
WEATHERPROOF DISC. SWITCH
4" CM. x .226 (WALL) SUPPORT
with 36" THK. STEEL CAP PLATE
and' /4' THK. STEEL STAB RINGS.
18" AT FILLER
.063" ALUM. FILLER
1 r/a" ALUM. SQ. TUBE FRAME
.150" WHITE LEXAN
FACE
SECTION "A" THRU FILLER
NTS
WORK ORDER NO.
SIB'. 2 cf 2 DATE: 03.26.01
�-�
Chandler
Signs
www. chandlersigns.com
3201 Manor Way 214-902-2000
Dallas, TX 75050 Fax 214-902-2044
2420 Valiant 210-349-3804
San Antonio, TX 78216 Fax 210-349-8724
16740 Hedgecxoft - Suite 400 281-931-9050
Houston, TX 77060 Fax 281-931.9011
2420 Vista Way - Suite 200 H 160-967-7003
Oceanside, CA 92054 Fax 760-967-7033
750 E. Hwy. 24 - Bldg. 2, Suite 200 719-687-2501
Woodland Park, CO 80863 Fax 719-687-2506
CLIENT: Residence Inn
STREET:
CITY/STATE: Tukwila, WA
SALES: Bill Teel
ARTIST: PC
APPROVAL / DATE
CLIENT.
SALES.
ESTIMATING:
ART:
ENGINEERING:
LANDLORD:
This drawing is the property of Chandler Sigls, Inc. and al rights
to its use far reproduction are reserved by Chandler Signs. bc.
REVISION/ DATE
MATERIAL LISTS
4
F48 LAMPS
2
F60 LAMPS
2
F64 LAMPS
2
472 BALLAST
1
DISC. SWITCH
DISTRIBUTION OF PRINTS
MASTER
ELECT.
SHOP FILE
INST./SHIP
STK. RM.
CUSTOM
PAINT
ASSEMBLY
000000❑0
CRATE
HT. TR.
PLEX
VINYL
PATT.
CAD
CAM
NEON
00❑❑❑00❑
TOTAL
AWN. ASSY.
AWNING
ALUMINUM
SHOP #2
CHNL LTR.
LTR. PAINT
LTR. ASSY
LTR. PLX.
0❑0000❑0
BES A FIRE ACCESS EASEMENT 20 FEET IN WIDTH HAVING 10
-1 SIDE OF THE CENTERLINE DESCRIBED IN SAID EASEMENT.
TTED ON THIS SURVEY.
RANTS A PERPETUAL NON-EXCLUSIVE EASEMENT FOR
I, REPLACING WATER METERS, WATER LINES AND SEWER
2 OF SHORT PLAT NUMBER 84 -31 -SS, ACCORDING TO THE
UNDER KING COUN11' RECORDING NUMBER 8501030748.
/NCS
YO 72"E
341,0cre
25'3'9"E
25 '31"6-
'0'24"C
39"E'0'24"E
59'59"W
18' 48"W
Z 48"W
5-2'21"W
/IC,. L.: -et
� / �...
D/STANCE
2524' _
/ 73 50'
27. /5'
45.81'
7/.43'
/G7.69'
84.55'
840'
1.34'
X7`31" W
23..99'
RAO/a5
L E' is TN
48-00'
58.30'
35.00'
42.92'
240.00'
352.58'
220.00 '
49.84'
220.00'
/68.2/'
30.00'
30.55'
30.00'
36-G5'
4i/.5O Z, Z9"
N 08�
w
0*-
7--
(>1.,
"
cps
O
•
as artier
k7k
cr
00 -ii DIS /
Cf. Oe (1-01104e9)
8 , 4,044 . yvI/1
t
4
A SZ.
•
5(2
0
44
4
a o.•
7,
•
•
I
•
. o:
II��Ao
6i
.� .
O�e
•
•
a
hl
Q,
RL
O.
'3
11,
\
.v
•
I
•
C
Q:. J
%1, 6
ti
Nor.
0
41.
C' 4(2
2,0
o,
'3
0 •
\; G
°, Y4_
/nq g.G
icor?? Cot
ZJnfavorof O
•
W
0
i�
D yard 1'
32.65'
3
4a weed remc,
Of?'
67.96'
ID "
•
"lea) Dlf
LLum p L
sl -of
C.&
ay./EWA Y
cur
WEST VALLEY
STATE rii4r-IWAy 4181
•
J7/11H
If6*.70' 4140 1.
gi&iIWA y'
/93. Z4'
NOTES:
2.
-�—
FLOOD INSURANCE RATE MAP COMMUNITY PANEL NUMBER 530091-0002-B SHOWS TH
PROPERTY iN ZONE C.
2. ALL BUILDING TIES ARE 90° TO PROPERTY LINES, OR RADIAL TO CURVED TOP OF BAN
LINE AS ESTABLISHED BY FIELD SURVEY RECORDED IN BOOK 32 OF SURVEYS ON PAS
211, EXCEPT THOSE SHOWN WITH BEARINGS.
3. POWER VAULTS HAVE BEEN FIELD LOCATED. THE BURIED POWER LINES WERE
LOCATED AND PAINTED ON THE GROUND BY LOCATING INC., THEN FIELD LOCATED B'
TRI -COUNTY LAND SURVEYING COMPANY. EASEMENT PER A.F.#8504010816.
EASEMENT IS 10 FEET WIDE, HAVING 5 FEET OF SUCH WIDTH ON EACH SIDF OF THF"