HomeMy WebLinkAboutPermit S02-049 - KEY BANKKEY BANK
3434 S 152
P -SIGN
502-049
SITE INSPECTION (PLANNING)
File No. S02-049
Name of Tenant: Key Bank
Sign Address: 3434 S 152" St
Date Photo Taken: 11 March 2003
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of (date)
Make new site visit and taken photo by
Comments:
(date)
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670
Typ o€-Inspect}on:
Scp-DLO
PER
341 5
s ?
Special Instructions:
Date Cal
Corrections required prior to approval.
IInspeetor: /' 1,
$47.00 REINSPECTION FEEiREQUIRED. Prior tinspection, fee must be
I paid at 6300 Southcenter Blvd., Suite 100. Cab to schedule reinspection.
narP�
Date:
!a
• •
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
Parcel No.: 0041000495
Address: 3434 S 152 ST TUKW
Suite No:
PERMANENT SIGN PERMIT
Permit Number: S02-049
Issue Date: 09/25/2002
Permit Expires On: 03/25/2003
Business
Name: KEY BANK Phone: 206 241-9335
Address: 3434 S 152ND ST, TUKWILA
Property Owner:
Name: KEY BANK Phone:
Address:
Contact Person:
Name: CONNIE GUFFEY Phone: 253 473-3323 x10
Address: 5835 S ADAMS
Contractor:
Name: PLUMB SIGNS INC Phone: 253 473-3323
Address: 5838 S ADAMS
DESCRIPTION OF WORK:
WALL SIGN mounted on North face and free standing sign on corner of 152nd and Hwy 99
Fees Collected: $200.00
PERMANENT SIGN:
Zoning: RC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wali Area (sq. feet): 1120 0 0 0
Wall Sign Size (sq. feet): 33.75 0 0 0
Sign Lighting:
Face Residential Land: N N N N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 125 0
Building Height (feet): 16 0
Sign Size (sq. feet): .75 0
Sign Height (feet and inches): 15' 0" 0' 0"
Setback (feet): 15 0
Number of Sign Faces: 2 0
Planning Division Authorized Signature:-- QMV\v-N Date: \ ---
I
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE
OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: Permsign
S02-049 Printed: 09-26-2002
City of fukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
RECEIPT
Parcel No.:
Address:
Suite No:
Applicant: PLUMB SIGNS
Permit Number: S02-049
Status: ISSUED
Applied Date: 09/24/2002
Issue Date: 09/25/2002
Receipt No.: 8020001403 Payment Amount: 100.00
Initials: AP Payment Date: 09/24/2002 12:39 PM
User ID: 0100 Balance: $0.00
Payee: PLUMB SIGNS
TRANSACTION LIST:
Type
Description Amount
Payment Check 12132
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
Method
100.00
SIGN PERMIT
000/322.100 100.00
Total: 100.00
doc: Receipt Printed: 09-26-2002
Key Rank
Business Name
City of Tukwila
Department Illkommunity Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
(206)431-3670 - ;,1
PERMANENT SIGN PERMIT APPLICATION
PERMIT.
O. —Rea 0 6✓.4L.L,
CITYOFT KWitA
SEP 2 '+ 2002
Connie Guffey
Applicant/Contact
Plumb Signs Inc.
Contractor
NTER
Please print
3434 tS. 152nd
Address of Sign
5838 S. Adams,
Tacoma 98409
Address, City, State, Zip
5838 S. Adams,
Tacoma, 98409
Address, City, State, Zip
(206) 241-9335
Phone
(253) 473-3323 X10
Phone
(253) 473-3323
Phone
CHECKLIST
3 sets of plans (dimensioned and scaled), including site
plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
❑ Sign elevations with area calculations and dimensions
❑ Building elevations (for wall signs)
❑ Supporting structure and method of illumination
❑ One copy of valid Washington State contractor's license
❑ $50 application fee per sign, or 50 cents per sq. ft.,
whichever is greater.
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go
through structural review.
STRUCTURAL REVIEW CHECKLIST:
O $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
O Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding 1
Did building go through design review? ❑ Yes Et No
Wall
1
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) where the sign will be
mounted? (square feet)
1,120
Reface
1,120
Sign size(square feet)
'`I-3 317 5
,-4-.-4'2--..
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
'
No
(„„--:---''
No
Does wall sign weigh more than 400 pounds?(Y/N)
No
No
Sign illumination (internal/external/none)
Int
Int
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
140 ' on Pa
12 5 ' on S.
c i f i c Hwy
152nd S t .
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
16'
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
-- 33.75
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
15'
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all property lines a distance equal to their height.
15 '
Number of sign faces
INSPECTIONS
2
y=
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor
and Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that
the applicable requirements of the City of Tukwila •e met.
9/20/02 �� /0;Cr / 'i
FOR OFFICE USE ONLY
Date ignature of owner or author' ed age
Zoning:
(253) 473-3323 X10
Phone
Planning review by:
O Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
O Denied ❑ Approved 0 Approved with conditions
1
31-4 "
FACE REPLACEMENT LAYOUT:1 '/z'= 1'-0"
NOTES:
MANUFACTURE AND INSTALL ONE(1)
FLAT LEXAN FACE REPLACEMENT FOR AN
EXISTING INTERNALLY -ILLUMINATED
ATM HEADER.
BACKGROUND OF FACE TO BE BLACK
KEY COPY TO BE WHITE.
ATM ELEVATION: 3/4"= 1'-0"
•
O -i KeyBank
3434 S 152nd Street
Tukwila, Washington
—
15'-01 /2" setback from
inside edges of sidewalks
toJeadtng edge of sign
0
PACIFIC HIGHWAY SOUTH
S 152ND STREET
®. P34 d/f pole sign
/ B02-1476
®WS34 s/f wall sign
B02-1569
NOTE
All signs not noted
on the site plan are
to remain "as is"
r
ATM header face
replacement Bo2-1572
=indicates existing sign is to be removed
and replaced with new sign
MILITARY ROAD SOUTH
•
(rAee e#209Ami
FACE REPLACEMENT LAYOUT: 1 f= 1 '-0"
NOTES:
MANUFACTURE AND INSTALL ONE(1)
FLAT LEXAN FACE REPLACEMENT FOR AN
EXISTING INTERNALLY -ILLUMINATED
ATM HEADER.
BACKGROUND OF FACE TO BE WHITE.
KEY LOGO TO BE RED PMS 032.
•
''.
.• a - '-',1'1•-. ,.:,, 3.,.:..,,,,,,..- ,.,. ,,,a;...;...,.„..; ,•:.7...7.::-, . s. ',1.,.,,:-.::.. ,..r. .z•-••...,,,.
.
•• h:
'' '-'', •-:ft_...:'-'_,...ta ,,,.
'..' .... ,...
.ii..M'
3 :.•:-.4-'43,.'Vz::.,...:5„:3-ag3:6.,;,......'„....1- r. -,r.1.-•?.'7, b,..r.,....21,•--;;.,...,.•,_,•„7„,,,riv,,,-,..,-4:7_,,,,,:,
.k.....s . e.
. .. •,-„,,,T,...,
0 .
..M3334i3r
• , •
.„.. .... .
• .
•
.. . _
. .. .• i
.. ' .
....3,:•-!..-......3:., .: .11,..-S-,-, 1 ' I .:133.73,.3 '.‹,:•'.57"c:4•17.3.‘.:51 -..,";3;.7-'4V;.•,-•••`.3'•;..,.. k....,,-.: .3 ..,•,4,:, : „ .. ,;1 . ,- -,,a.....,... ..- 3 • • .., • : ,..-A,•,. „ -.....!
. ,
•
.
r ,. .. .. .'
, ...
•
3.
•,.
ATM ELEVATION: 3/4"= 1'-0"
•
0I -Z00
lil Zs= ili la
ZAPIEZ 0
talaiaZZ
-1 1
SOCW.A.40z
4..Z1...iZWI
:3 2ZerliCie
i**10geall
41 i. 4 la*,
...iigue...
. a.—Liuma
• — cp.. ..„
Coac2w7".
V'. 0 ire Krer4
41110 0—
.., atli• amo m• mv,
=000T4'.
CiliZill
f24).C2tec
Z•i. •
i'11202°
m11100
111%2Z).!
l'•10ZCOm
CC 000
Z041011,0
I
4811 VAN EPPS RD., CLEVELAND, OHIO 44131
•
0
_A-
1
1
1
•
- .
.47,4,?6:p4.--, •
' -
51-1" iREPIA(EABLE PANEY__
. _ •
l'-5 1/4"
11-8 1/2"
g,
NOTES:
DOUBLE -FACE, INTERNALLY -ILLUMINATED, FABRICATED
ALUMINUM PYLON SIGN.
• KEY TO BE CUT OUT OF ALUMINUM FACE; OPENING TO BE
BACKED -UP WITH WHITE #2447 PLEXIGLAS WITH FIRST
- SURFACE APPLIED RED TRANSLUCENT VINYL #3630-33.
"KEYBANK' TO BE CUT OUT OF REMOVABLE ALUMINUM
PANEL WITH OPENINGS BACKED- UP-W1TH WHITE
#7328 PLEXIGLAS.
LOWER PORTION OF FACE BACKGROUND AND CABINET
TO BE PAINTED SATIN BLACK.
UPPER PORTION OF FACE AND CABINET TO BE PAINTED
GRIP GOD 00 WHITE WITH A COARSE STIPPLE FINISH.
PYLON POLE COVER TO BE PAINTED SATIN BLACK.
RATED 120 VOLTS
POLE SIGN ELEVATION: 1/2"= 1'4"
P34
MogiV 0
42405113
aZO 0
Lc o•
be-visSO
4
;Pen
illri
' it-imitS1).
EE,foun3
cm=21114
-
011011.01
-Z044-14 'Ill
t 4611 g F. IS 1
1.28:5:E
CuiZI:g
• .12UCI)...ec
ti0r: 0
I -Z220
iittgioui
tcningss
z......
. „.
J
2
(
3-
F48T12CWHOuorescent lamps; 6 req. F24T12CWH0 lamps; req.s• 2
INTERNAL LAYOUT SCALE 3/4" = 11-0"
fixed half of sign
hinged half of sign
foam gasket
11
flat head
machine screws
photo cell/
toggle dis-
connect
448D
ballast;
2 req.,
2.3 amps
each
C5x9.0 CHANNEL FRAME
CONTINUOUS PIANO HINGE
1/8" alum. face
smi
plex back-ups
.125 aluminum -
face / replaceable
panel
1 1/2"x 1 1/2"x3/16"
aluminum angle frame
iIIIL1 i111
fixed half of sign
hinged half of sign
11
C5x9.0 channel
2" x 2" x 1/8" aluminum
closure clips
I_
mix] il:rPT]'
LILL......m.....
REPLACEABLE PANEL ATTACHMENT DETAIL - FULL SIZE
# 10-24 aluminum studs
CABINET SECTION 3 = 11-0"
P34 DETAILS - SHEET 1 OF 3
fixed side
BOTTOM OF
CABINET
N
%`' removable side
SUPPORT POST / POLE COVER BRACKET DETAIL 3/4" = 1'-0"
21 /2" square tube through cabinet
81 /2"
7 "
5/8" dia. holes
7/8" dia. service hole
•
jI 1
3/4"
DETAIL OF TOP COMPANION PLATES 3" = 1'-0"
GRADE
4" square tube/
.250 wall
1'-1 1/2"
4 3/16" radius
1 I/2"x11/2"
x 3/16" angle
iron brackets
.090 aluminum pole cover
POLE COVER SEAM -1 /2 ACTUAL
11"
1 1/16" dia. holes
3/4"
BASE PLATE DETAIL 1-1/2" = P-0 .
P34 DETAILS - SHEET 2 OF 3
r
3'-81 /2"
1
2'-4'/2"
83/4"
'-1" (REPLACEABLE PANEL)
WALL SIGN ELEVATION - 3/4 „= 1'-0"
NOTES:
SINGLE -FACE, INTERNALLY -ILLUMINATED, FABRICATED
ALUMINUM WALL SIGN.
KEY TO BE CUT OUT OF ALUMINUM FACE; OPENING TO BE
BACKED -UP WITH WHITE #2447 PLEXIGLAS WITH FIRST
SURFACE APPLIED RED TRANSLUCENT VINYL #363043.
"KEYBANIr" TO BE CUT OUT OF REMOVABLE ALUMINUM
PANEL WITH OPENINGS BACKED- UP WITH WHITE
#7328 PLEXIGLAS.
LOWER PORTION OF FACE BACKGROUND AND CABINET
TO BE PAINTED SATIN BLACK.
UPPER PORTION OF FACE AND CABINET TO BE PAINTED
GRIP GARD 00 WHITE WITH A COARSE STIPPLE FINISH.
RATED 120 VOLTS
CA -04TH) FRONT BUILDING ELEVATION: 1 /8"=1O"
w=Z
Stlit
moz.dOj
d az 2
strait
Zi-.Z2�W,S
irizr mZOILO=
aOm
�o�
FCPUt
_og-wO
,2 of
•.- O.
W30Z�W
00000
1
T
Y
GRADE
leveling nuts
1
electric J -box
non -shrink grout
7/8" dia. anchor bolts
C O £ 133HS - SltVI3El LSd
E
oa
electric supply in
1/2" or 3/4" rigid
conduit �
b
2'-0 " diameter
Brilliant Electric Sign Co., Ltd.
4811 VAN EPPS RD., CLEVELAND, OHIO 44131 (216)741-38004
NOTE: THIS I§'AN'ORIGINAL UNPUBLISHED,
DRAINING. .CREATED' oY BRIWANTfSIGNS;, rr
ISSUBMIT ED FONIYOUROPERSONAI.= iN
CONNECTION WUN A PROJECT�BEWG PLS N ED
FOR YOU. IT IS NOT-TO'BE USED:REPRODUCED,
COPIED OR EXHIBITED M ANY FASHION.
AttgoOrt
II
COMA'. Y NAME
�•r-�►�-
" SALESMANDMREVISION.DESIGN
_ HCA
---0 r
NQ
o
DESIGNER
wc.glON
vNIA-0 v 5
DM
SC E
11 �," / u
=coPYTCM ,,
enol,