Loading...
HomeMy WebLinkAboutPermit S03-001 - TUKWILA INNTUKWILA INN 13050 48TH AVE S S03.001 City ofIrukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: Address: Suite No: 0003000030 13050 48 AV S TUKW PERMANENT SIGN PERMIT Permit Number: Issue Date: Permit Expires On: S03-001 01/14/2003 07/14/2003 Business Name: Address: Property Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: TUKWILA INN 13050 48TH AVE S, STRANDER JOHN B 2603 151ST PL NE FEDERAL WAY SIGN CO. 1908 S 341 PL FEDERAL WAY SIGN CO 30665 MILITARY RD S Phone: 206 2412200 Phone: Phone: 253 529 2011 Phone: 253-529-2011 DESCRIPTION OF WORK: One wall sign 48 sf and one freestanding sign 108 sf (freeway interchange sign) "Tukwila Inn" Fees Collected: PERMANENT SIGN: Wall Area (sq. feet): Wall Sign Size (sq. feet): Sign Lighting: Face Residential Land: $200.00 Zoning: C/LI Sign Type: Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Wall Sign #1 1300 48 Wall Sign #2 0 0 N N Freestanding Sign #1 354 45 108 45' 0" 50 2 Wall Sign #3 0 0 Wall Sign #4 0 0 N N Freestanding Sign #2 0 0 0 0' 0" 0 0 Planning Division Authorized Signature: Date: — `-1 A I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with; whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: Permsign S03-001 Printed: 01-14-2003 SITE INSPECTION (PLANNING) File No. S03-001 Name of Tenant: Tukwila Inn Sign Address: 13050 48th Ave S Date Photo Taken: February 18, 2003 x Freeway sign appears to conform to permit application Sign appears different from permit application X Wall Sign not installed as of 02/18/03 (date) Make new site visit and taken photo by (date) Comments: TU. NSILA • INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431-3670 Projec /J/t W/ �' Type of Intion: / / 17Q/ Add/ 5-0 ie, xi, s Date dj 3 Special Instructions: Date Wanted: a.m. p.m. Requester: ,/i Phone No: S coP// ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: S� ti c X \V, i Insp cto : Da e: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaII to schedule reinspection. Receipt No.: Date: 6So� I-- asp 54(157-. S1roN 415" Gam' 1-03-Vt.% Ave. S. SiT� TUKWILA INN / Sc.: 1" = loo\ golden nugget awning espresso stand pole sign elevation wall sign b elevation tukwila inn sign DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST: CONT SPECIALTY REG:IST;.i-# EXP. DATE CCCI FEDERWS110JL 03/22/2003 'EFFECTIVE -DATE _- 04/13/1989 FEDERAL. WAY SIGN CO 30665 MILITARY RD S AUBURN WA 98001 F625-052-000 (8/97) DLtach Anil Display Certificate City oukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 (206) 431-3670 ,5n3 0O( PERI 10. PERMANENT SIGN PERMIT APPLICATION TOKWtt—k IN i Business Name %'1t t.A N Please print 13050 4-8+1(.. >c. S . Ttvg.A.0t Address of Sign 90 8 s . batt . 53-u.i4( 5 'FED. u)ati, Applicant/Contact Address, City, State, Zip F€IEit AL WAY 3(C•a) CO• Contractor 1x40 8 S. batt sr4- 84-. • if 5 FEm. WAY Address, City, State, Zip (2.06) 241 — 2,0 Phone 2 5 S'2-9 — 2-o t t Phone 51-9 — 2-O t. t Phone CHECKLIST 0 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings ow? 3 00 -003 0 • Locations of all existing and proposed signs1.5 Sign elevations with area calculations and djrper sions Building elevations (for wall signs) Rt,A�T GE Supporting structure and method of illuminati8r One copy of valid Washington State contractor's license $100 application fee per sign, or 50 cents per sq. ft., whichever is greater. See back of form for examples Is y r sign a: Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STI(JCTURAL REVIEW CHECKLIST: $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? 0 Yes 0 No Wall 1 WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) 1 t3oo Sign size(square feet) I$ Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. N 0 Does wall sign weigh more than 400 pounds?(Y/N) No Sign illumination (internal/extemal/none) 1.,.�-eru...riQ. FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. ICI -1 - Height of building (feet). Generally, signs may not be higher than the building with which they are associated LI's Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area t og Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. ItS- Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. c0 Number of sign faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. IHEREBY CERTIFY that the above -information furnished by mei ;-true-an the applicable requirements of the City df Tukwila will be met. 1— 3— 'o3 Date Zoning: rrect under penalty of perjury by law in the State of Washington, and that (Signature of owner or authorized agent) FOR OFFICE USE ONLY (2-5 5-t-9 — 20 h Phone Planning review by: • O Denied Issued 0 Issued with conditions Structural review required? Yes 0 No Structural review by: O Denied ❑ Approved 0 Approved with conditions 16' Tukwila Train IIob8 _ Sign 'Area Ii Area is calculated by constructing a polygon around the sign using right angles., Big Store \ \. -\ \ \ \ \ \ \ ..\\\ \\ \ \ \ \ \ \ \ \\ , \\ \\ \\ \_ \\\ \\\ Building Elevation • Wall Area Is calculated by multiplying the length and height of (he tenant space. I -1) 7.11.1 l l I I I E 1 flSig 1 I I{ I I (.) Property Lines N SITEjJLrASING TLA—. N Site Plan -All up. AMP Cnu.0 v1.111 .n1 Ul Irrn0.1. AMI - P 111 11111 ANO IOCIL IU,l0m0 Ino 111C1111CAL C0011 111111 011.1 1.11111111 • IACOI 1 0011 P IIu11N n1l Vr.f ,' 1'110! (II' 11110 I I.I 1 X1 rt rtn 1V,„"IM ' { I Irl/t COr.•11CIOn RI1..I.AN I.C1 = -� ��11011p1l 7101 Tt Ui Ilwnrar+ueol 941 IMMIIOnulnl IO O Ioa rai 111011100 0o 1.1V 1r1 1t 7711 1 1 ca.LL 1A1 ntanlq 111701/0 lana r.Cl.111t010 P4700101101111110 -•---1. Iltrllia GOI (1171n Wall Mount Detail For all wall mounted signs over 400 lbs; 1/a" "in•LP✓ t w3wf0 '1b Pcul W O ^Triol ep 'rti 61[11) w/ %. 11E*L 131uT- • 1%L Q1 Sul 10 /UI.G Cj>t -•/4"•11—c,' Footing Detail Show applicant space and all existing & proposed signs. For all Freestanding Signs .EXAMPLE lbF REQUIRED INPORMATInN