Loading...
HomeMy WebLinkAboutPermit S03-027 - NORTHWEST SAFE COMPANYNORTHWEST SAFE CO 530 STRANDER BLVD S03427 City oftukwila i Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: 0223200042 Address: 530 STRANDER BL TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: Issue Date: Permit Expires On: SO3-027 Business Name: NORTHWET SAFE CO. Address: 530 STRANDER BLVD., TUKWILA, WA Property Owner: Name: POLICH FAMILY TRUST Address: POLICH BONITA M ADM Contact Person: Name: Address: Contractor: Name: IDENTITY SOLUTIONS Address: 4210 SW OREGON ST Phone: 206-242-7233 Phone: Phone: Phone: 206-4366 DESCRIPTION OF WORK: One perm. wall sign approx. 59 square feet, "Northwest Safe Co". Fees Collected: $400.00 Zoning: TUC Sign Type: PERMANENT SIGN: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 1000 0 0 0 Wall Sign Size (sq. feet): 59 0 0 0 Sign Lighting: Face Residential Land: N N N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0' 0" 0' 0" Setback (feet): 0 0 Number of Sign Faces: 0 1 0 Planning Division Authorized Signature: f3 Date: 51130 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE doc: Permsign S03-027 Printed: 05-12-2003 • City of Tukwila • Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: 0223200042 Address: 530 STRANDER BL TUKW Suite No: Tenant: NORTHWEST SAFE CO. PERMIT CONDITIONS Permit Number: S03-027 Status: PENDING Applied Date: 05/08/2003 Issue Date: 1: The awning must meet all UBC standards for wind load. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume • give authority to violate or cancel the provision of any other work or local laws regulating constru '• i or the performance o work. Signatu e: //i '�; Date: J — Print Name: 1441(42 ri-ANsEy doc: Conditions S03-027 Printed: 05-12-2003 SITE INSPECTION (PLANNING) File No. S03-027 Name of Tenant: Northwest Safe Co. Sign Address: 530 Strander Blvd, Tukwila Date Photo Taken: 11-12-03 x Sign appears to conform to permit application Comments: Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) City of Tg,gkwila Steven M. Mullet, Mayor Dep ailment of Community Development Steve Lancaster, Director NOTICE OF DECISION This letter serves as a Notice of Decision and is issued pursuant to Tukwila Municipal Code (TMC) 18.401.170. The request for an increase, from 45 -sq. ft. to 59 -sq. ft. for Northwest Safe Co. at 530 Strander Blvd. This decision is based on the Findings and Conclusions listed below. BACKGROUND File Number: S03-027 Applicant: Identity Solutions for Northwest Safe Company Request: Approval for a Special Permission Sign, increasing the allowed sign area. The maximum allowed sign is proposed to be increased from 45- sq. ft. to 59- sq. ft. Location: 530 Strander Blvd Comprehensive Plan Designation: TUC Zoning District: TUC SEPA: No determination required Staff: Brandon J. Miles FINDINGS Vicinity/Site Information The sign being proposed will be located on the south wall of 530 Strander Blvd and will face directly towards Strander Blvd. The zoning on the property is Tukwila Urban Center and surrounding land uses are commercial. The exposed building face (EBF) is 1,000 square feet. With the approval of the Special Permission Application, the wall sign would be 59 square feet (5.9% of EBF) versus the normal maximum of 45 square feet (4.5% of EBF). 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206-431-3670 0 Fax: 206-431-3665 i L01-026 Page 2 of 3 FINDINGS Vicinity/Site Information The sign being proposed will be located on the south wall of 530 Strander Blvd and will face directly towards Strander Blvd. The zoning on the property is Tukwila Urban Center and surrounding land uses are commercial. The exposed building face (EBF) is 1,000 square feet. With the approval of the Special Permission Application, the wall sign would be 59 square feet (5.9% of EBF) versus the normal maximum of 45 square feet (4.5% of EBF). Decisional Criteria TMC 19.32.140(A) allows permitted sign area to be increased by 50% for each doubling of the required minimum setback...but in no case shall the sign area exceed that permitted in TMC 19.32.150. Pursuant to TMC 19.32.150, the maximum allowed sign area could be 6% of the exposed building face (EBF) up to maximum of 500 sq. ft. The required front setback in the Tukwila Urban Center is 15 feet. The building has a setback of 58 feet, 3.8 times the required distance. Per Table 1 of TMC 19.32.140, the standard allowed sign area would normally be 45- sq. ft. for an EBF of 1,000. ft. Since the building is setback 3.8 times the minimum setback required for the underlying zone, the maximum sign area is allowed to be increased 50% for each doubling of the required minimum setback up to 6% of EBF or 500 sq. ft., whichever is less. Six percent of EBF (1,000 -sq. ft.) is 60 -sq. ft; thus the maximum allowed sign area on west facade is 60 -sq. ft. CONCLUSIONS 1. The building is setback a sufficient distance to allow an increase in the wall sign area. 2 The proposed sign area is 59 -sq. ft., which less than maximum permitted for that facade (6% of EBF -60 sq. ft.). APPEAL PROCESS This decision may be appealed to the Planning Commission within 14 days from the issuance of this Notice of Decision. All appeal material must be submitted to the Department of Community Development. If you wish to appeal this decision, please call the Department of Community Development at 206-431-3670 to obtain a copy of appeal procedures. Steve Lancaster, Director of Community Development 03 Date Vee City of Tukwila 1Facruz Mike Hansen @ IDENTITY Solutions CO NA [fie 05/09/03 Rex Northwest safe co. Awning Request ger Specilell comelidenntlat We have a ao on the design of the Exterior evenings on the Northwest Safe Co.. However, due to the way the city of Tukwila determines the way of determining the sq. footage of signs, we ask that the special stipulation for a set back of more than 50' feet be considered on the maximum sq. ft on this job. I have been waiting for over 4 months for this awning JOB, to come to fruition. I would also like to have a great working relationship with the city, and do some future work in your city. However, we need to have this special consideration for th' project, as we feel that it will greatly enhance the business revenues and also be an attractive ad . ' ori to the start of the Strander Blvd. Strip. Thank you! Please don't hesitate to call for any clarification or questions you may have. (206) 465-9508 0 Page 1 ti F625-052.000 (8/971 DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST:'CONT SPECIALTY F5 wtf RE�ZS'l;rI#:` `>EXP -DATE: CCCLCBIDENTS*97.9KG` 05/07/12005; EFFECTIVE DATE 05/07./,`20-03 •-r.• IDENTITY' SOLUTIONS 4210" SW OREGON. ST- SW SEATTLE WA 98116 Detach And Display Certificate LICENSE DETAIL INFORMATION Form• Page 1 of 2 STATE OF WASHINGTON DEPARTMENT OF LABOR AND INDUSTRIES Specialty Compliance Services Division P. O. Box 44000 Olympia, WA 98504-4000 THE RESULT OF YOUR INQUIRY FOR LICENSE NUMBER SELECTED IS: LICENSE DETAIL INFORMATION Current Filter: None Registration# or License IDENTS*979KG Name IDENTITY SOLUTIONS Address 4210 SW OREGON ST SW Address City SEATTLE State WA Zip 98116 Phone Number 2069384366 Effective Date 5/7/2003 Expiration Date 5/7/2005 Registration Status ACTIVE Type CONSTRUCTION CONTRACTOR Entity INDIVIDUAL Specialty Code SIGNS NON ELECTRICAL Other Specialties PAINTING/WALLCOVERING UBI Number 601876131 * * *VIEW CROSS REFERENCE FILE FOR THIS LICENSE* * * 'VIEW *VIEW PRINCIPAL OWNER(S) FOR THIS LICENSE* * * 'VIEW *VIEW CONTRACTOR BOND/SAVINGS INFORMATION * * * 'CHECK *CHECK INQUIRY FOR SUMMONS AND COMPLAINTS* * * * * * VIEW CONTRACTOR INSURANCE INFORMATION * * * New inquiry by CITY , NAME , PRINCIPAL OWNER NAME , LICENSE , UBI NUMBER, check the L&I Contractor Industrial Insurance Premium Status or return to the L&I Construction Compliance Home Page httns://wws2.wa.gov/lni/bbin/TF2Form.asn?License=IDENTS*979KG 05/09/2003 City. Tukwila Department- of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 (206) 431-3670 P•T NO. cz PERMANENT SIGN PERMIT APPLICATION Please print --� �u yrll� zv6 IUo v� 5-e Co tv44- 5 z, de 2 Blvd Z'72 -72 33 Business Name Addres of Sign Phone PPCUI P ts-71e. A -5 -Se—. Applicant/Cont Contractor ox. Address City State Zip Phone /� �eZ /O ..5c0�12�- �b7(� s 5-0A-i�'-(? Za) J 3 Address, City, State, Zip 9.`/ Phone 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $100 application fee per sign, or 50 cents per sq. ft, whichever is greater. See back of form for examples How many signs will list this business? Freestanding Did building go through design review? 0 Yes 0 No Is your sign a: ❑ Freestanding sign 15 or more feet in height ❑ Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION Wall WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) t to00 Sign size(square feet) ` ' S" 1 Does sign face residential zones or public facilities? (Y0 Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. i.v 0 Does wall sign weigh more than 400 pounds?(Y/N) /U 0 Sign illumination (internal/external/none) FREESTANDING SIGNS: U ►vaut= #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of sign faces INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A struct Divisio ur�Lnspe ion is require or at 431-3670 for a final inspection. It is the respon and Indust' o ► ns a s at (206) 248-6630. s when installation is complete. The applicant or installer is required to call the Planning btain the electrical permit and inspections from the Washington State Department of Labor RMIT APPLICATION IS VALID F I HEREBY CERTIFY that the above information furni . -. the applicable requirements of the City dfiTuk '� AL by me is true and et. Date 5-1 Zoning: tIAC- r( 180 DAYS AFTER ISSUANCE. ct under penalty of perjury by law in the State of Washington, and that gnature of owner or thorized agent) FOR OFFICE USE ONLY 95 75VikP Phone Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: O Denied 0 Approved 0 Approved with conditions ' / n .Area r '1 rr'1 1J'tain & HobbLy � ISign Area Is calculaiea by constructing a polygon around the sign using right angl;;:s. `41R,7Big Store \ \ \ e \ \ \\ \ \ \ \\ \ \ ', \ \ \ _ \\ \\ \ \ �_ \"1\\\ `\\ 11/11411 Building Elevation • Wall Area Is calculated by multiplying the Iehgth and height of the tenant space. -4, fl 1 '11111111 fl SIU 1111 1111 Property Llnes Site Plan r Pot W' All 1101.1 000 11 Ant K API/I0111• Ant 11111 111111 IWO LOCM 90100•0 Ano 1l\CI n.O At 00011 RIAA/ANY/KI K01111110 11,111 1111111 nt . 01011 1 01110 01.1,11 111010 r..0I 11'I10l1 run t1111A 110111.4 lq 0140 COw11CIOl /KR1r COW, ��10011I101OI I1n1 t1wl10101ln 000 10111143000141001(00011(11 POW rot q Ic110 • IROO IACIAI 11010 ocrlito, 1,01 11(1111 1011 1000•II ytn o41rtq Wall Mount Detail For all wall mounted signs over 4OO tbs:. - - Ya •Iatupixs lb PC(.Q WO 4TTA ulec, ,U 8.4•J 10/ 0/tl 11LX DUS-Tir • r%."Q7 c!00 io rete. J/'I-11-Or Footing Detail ;how applicant space.and all existing & proposed signs. For all Freestanding Signs EXAMPLE OF REQUIRED IMFfRIVIATlnM 2'-0" Strander Blvd. 26'-0" 6'-0" Copy Both Ends End View 30=0" 3=0"x5'0"=15SgFt Copy Area 2'-0" x 22'-0" = 44Sq. Ft. 3'0" All Outside Framework 1" x1"x .065 Wall Steel Tube Fully Welded, Primed And Painted Northwest Safe Face Elevation Awning Display 1" x 1 " Steel Tube Frame Attachment Detail 2'0" Top View Scale: 1/8" = 1'-0" Identity Solutions Commercial Awnings and Signs Client: Northwest Safe Co. Date: 5/6/03 JGM Scale: Noted Designer: JGM Salesperson: Mike Hansen (206) 465-9508 This drawing is an original unpublished design created by and for Identity Solutions. It is the sole property of Identity Solutions and may not be used or reproduced in any way without the expressed permission of Michael Hansen or principals of Identity Solutions. Any use outside this agreement will constitute acceptance of the design and herein shall require payment of a design fee or Job acceptance. Z -Clip Awning Bracket Device. 0'3 3/8" Expansion Bolts Into Concrete Wall As Req. Scale: 3/8" = 1 '-0" Awning: Total Sq. Ft. 59Sq Ft. Awning Weight: Under 400# 50=-0" 30'-0" 530 Strander Blvd Front Scale 3/16" = l'-0"