Loading...
HomeMy WebLinkAboutPermit S04-060 - TUFF SHEDTUFF SHED 17500 WEST VALLEY HY 504-060 City of'1'ukwila • Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukv ila, WA 98188 / (206) 431-3670 Parcel No.: 2523049033 Address: 17500 WEST VALLEY HY TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: SO4-060 Issue Date: 08/12/2004 Permit Expires On: 02/08/2005 Business Name: TUFF SHED Phone: Address: 17500 WEST VALLEY HWY, TUKWILA, WA Property Owner: Name: ALCO INVESTMENT COMPANY Phone: Address: PO BOX 3546 Contact Person: Name: NANCY BRAEDT Phone: 253-833-2800 Address: 3931 B ST NW Contractor: Name: LUMIN-ART SIGNS Phone: 253-833-2800 Address: 3931 B. ST NW DESCRIPTION OF WORK: Installation of two wall signs. Sign A will be located on the west elevation and will say "TUFF SHED" and will be 101.3 square feet. Sign B will be located on the north elevation and will will feature the Tuff shed logo. The size of sign B will be 38.476 square feet. Please note that the temporary sign permit for the Tuff shed banner will expire on 8/14/2004. Fees Collected: $200.00 PERMANENT SIGN: Zoning: C/LI Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 2880 5180 0 0 Wall Sign Size (sq. feet): 101.6 39 0 0 Sign Lighting: Face Residential Land: N N N N Freestanding Sign #1 Street Frontage for Entire Lot: 0 Building Height (feet): 0 Sign Size (sq. feet): 0 Sign Height (feet and inches): 0' 0" Setback (feet): 0 Number of Sign Faces: 0 Planning Division Authorized Signature: Freestanding Sign #2 0 0 0 0' 0" 0 0 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and doc: Permsign SO4-060 Printed: 08-12-2004 • • SITE INSPECTION (PLANNING) File No. SO4-060 Name of Tenant: Tuff Shed Sign Address: 17500 West Valley Hwy Date Photo Taken: February 15, 2005 x Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: INSPECTION NO. INSPECTION RECORD �, j�Yn� Retain a copy with permit `( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 P. t: si/Leo, Type o spection Ad iii re aite DftaectIA Iifs'/ed �/ I( 1I Special Instructions: Dae Wanted: 014 p' , m. Request . IIr i l833-oo Ph N Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: A LW siwt' t..4 c,ip(i R7 137s '35'10 5e0 k( 13 1,2'f Inspector: Date: $47.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • SITE INSPECTION (PLANNING) File No. SO4-060 Name of Tenant: TUFF Shed Sign Address: West Valley Hwy Date Photo Taken: September 24, 2004 Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of (date) Make new site visit and taken photo by (date) Comments: ii01,,,I.01hMlii,;,.........,;"....',F'',:',1111','"...,':::',..;:...:.'1,11'..,.',0',:1,,INIIIRI.;,,,,': ::::::,71,...:111,11116i0!1:',h1;",,i'll::(4i'i...:!,11 ...,,,.„„. • RECEIVED AUG 1 0 MN COMMUNITY DEVELOPMENT City oukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 206 431-3670 PERMANENT SIGN PERMIT APPLICATION Business Name Applicant/Con F �C faact & A E OT Lkm0- s__ SicrE. Contractor Please print f1 L 2J LL4y Phone ��l - X 33 Address s of 13 �Ign I V , Li I'1Li 6(.111).41.0_11 _ s3 -333 - gYOV Alress, City, State, Zip Phone 1/ t Address, City, State, Zip L ( 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs CV Sign elevations with area calculations and dimensions _,/ Building elevations (for wall signs) • l3' Supporting structure and method of illumination cp, One copy of valid Washington State contractor's license [� $100 application fee per sign See back of form for examples How many signs will list this business? Freestanding our sign a: ❑ - • . nding sign 15 or more ❑ Pole sign wit - . - 0 s.. - ❑ Wall sign weighin. • *0 po If any of the abo structural re ew. Phone et in height re feet or more in area or more are true, the applicat STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer st go through SIGN DESCRIPTION Did building go through design review? 0 Yes E No Wall WALL SIGNS: P." #1 �v� #2 #3 #4 Wall area (length x height) where the sign will beak' .7 mounted? (square feet) cad Yv i " r a br a NX 6 ',� ✓.39 Sign size(square feet) 1 0 I r Q, 'Ob Does sign face residential zones o public facilities?J 1 (Y/N) C. (\le) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. Does wall sign weigh more than 400 pounds?(YQ � , / IV .�� Sign illumination (internal/external/none) n VAISAJYc&-O C11W""�"11� t/jMU FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only ane freestanding sign is allowed per premises. Height • •uilding (feet). Generally, signs may not be higher than the •.' iing with which they are associate. Size of sign face (sq - e feet). Structural review ' --quired for pole signs with faces 30 square feet or more in are. Sign height (feet -inches). Stru . • 1 review is required for signs 15 feet or more in height. Distance from cios- - edge of sign to • operty lines (feet). Generally, signs must be set back from all proper nes a distance equal to t ' height. Numbe • sign faces 4 INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing Inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HE EBY CERTIFY that the ....ve information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that t - -a. icable requireme tlof the Cit ',f Tukwila will be met. dill ��k ignature of owner or authorized agent) Zoning: FOR OFFICE USE ONLY Planning review by: 0 Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: 0 Denied 0 Approved 0 Approved with conditions 0 N 25'• CB Cl Richard Ellis 206-575-2553 • 1 25'-4" t r 1 DESC12IPTION 6'-17/8" r7F7 EL— SCALE: 3/16" =1' WEST ELEVATION ilding continues ,\ 20'-O" 1 28-0" INSTALL ONE SET OF SELF CONTAINED NEON CHANNEL LETTERS INSTALLATION TO CONCRETE WALL MOUNTED W/EXPANSION ANCHOR HARDWARE. NORTH ELEVATION c?‘ PROJECTMf FF SHED LOCATION Kent, WA DESCRIPTION ELEVATIONS R, x'2004-08-09 L21 SCALE 3/32" = 1' APPROVED BY x SALES PERSON Nancy Draedt DESIGNER Kirk Challstrom 3 DATE 2004-01-15 FILE NAME TSELV_R1.ai PAGE °F 1 COLORS PM5 C PMS C 7PMS C FONTSN/ A n PMS C PM5 C PMS C SCALE: 3/32" =1' umn- rt igns, nc. 3931 B St. NW Auburn, WA 98001 www.luminartsigns.com sales@luminartsigns.com 253.833.2800 800.925.8625 SCALE: 3/32" =1' ple Construction Detail for self-contained Channel Logo Mounted to Wall glass stands Concrete wall iii x face �1� U.L. approv transformer Expansion Hardware for Attachment neon r� MEMBER I4!A INTERNATIONAL SIGN ASSOCIATION © COPYRIGHT 2004. This design is the sole property of Lumin-Art Signs Inc. Reproduce only by expressed, written permission from Lumin-Art Signs, or a payment of 500.00 for each application of this artwork. CITE PLAN SCS: r.ie-o 0• SCALE 1" 40 AUG 10 2004 CDEVELOPMENT • SITE AND BUILDING STATISTICS BUILDING CODE: I1C '91 al/STATE AMENDMENTS ZONING: M-1 BUILDING AREA: 56,904 SF 517E AREA: 149,616 5F TENANT SPACE: CfFICE: 1,1448 5F UAREHCUSE: 105355 5F TOTAL: 18,2803 SF TYPE a CCNSTRUCTICM III -N SPRINCLERED PARKNG 5l4 I,1 15 STALLS (NO CHANGE) TAX ID NUMBER 263304-9033 LEGAL DESCRIPTION 114E NORTH 21125 FEET OF THE SOUTH 60110 FEET Cf THAT PORTION OF GOVERMENT LOT 1, SECTION 25, TO LNSHIP 23 NORTH. RANGE 4 EAST WM. LYING ILESTERLY a THE UIESTERLY MARGIN CF PUGET SCOW) POILER AND LIGHT COMPANY'S 100 FOOT UDE RIGHT -GF -WAY AND EASTERLY OF 711E WEST VALLEY ROAD A5 ESTABLISIED BY DEEDS RECORDED UNDER KNG COUNTY RECORDING 1405. 584953, 6509838 AND 6503166: SITUATE M THE CITY CF TUKULA, COUNTY OF KING, STATE OF WA514INGTOK VICINITY t SCALE: N.T.S. RECEIVED `AUG 10 20041 COMMUNITY DEVELOPMENT