HomeMy WebLinkAboutPermit S04-062 - RELAX THE BACKRELAX THE BACK
200 ANDOVER PK E
SO4-062
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
Parcel No.: 0223100099
Address: 200 ANDOVER PK E TUKW
Suite No:
PERMANENT SIGN PERMIT
Permit Number: SO4-062
Issue Date: 09/20/2004
Permit Expires On: 03/19/2005
Business
Name: RELAX THE BACK Phone:
Address: 200 ANDOVER PARK EAST, TUKWILA, WA
Property Owner:
Name: TRI -LAND CORPORATION Phone:
Address: 1325 4TH AVE SUITE #1940
Contact Person:
Name: NICK Phone: 800-925-6011
Address:
Contractor:
Name: CULBERTSON SIGN Phone: 800-925-6011
Address: 5209 122ND ST E
DESCRIPTION OF WORK:
Two wall signs for Relax the Back. Sign A will be located on the west elevation and will be 30.10
square feet in size. Sign B will be located on the Southwest elevation and will be 22.62 square
feet. SP from the Director was approved to increae the size of sign B.
Fees Collected: $200.00
PERMANENT SIGN:
Zoning: TUC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 702 378 0 0
Wall Sign Size (sq. feet): 30.1 22.62 0 0
Sign Lighting:
Face Residential Land: N N
N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 0 0
Building Height (feet): 0 0
Sign Size (sq. feet): 0 0
Sign Height (feet and inches): 0' 0" 0' 0"
Setback (feet): 0 / 0
Number of Sign Faces: 0 / 0
T�
4
• I r
Planning Division Authorized Signature: I
Date: 1
N
hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of I -w and
ordinances governing this work will be complied with, whether specified herein or not.
doc: Permsign
SO4-062
Printed: 09-20-2004
•
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE
OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST
INSPECTION.
doc: Permsign
SO4-062 Printed: 09-20-2004
SITE INSPECTION (PLANNING)
File No. SO4-062
Name of Tenant: Relax the Back
Sign Address: 200 Andover Pkwy. E., Tukwila, WA
Date Photo Taken: 03-14-05
x Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of
Comments:
Make new site visit and take photo by (date)
•
Ciij' of Tukwila
•
Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
NOTICE OF DECISION
This letter serves as a Notice of Decision and is issued pursuant to Tukwila Municipal Code (TMC)
18.401.170.
Request for an increase, from 18.9 sq. ft. to 22.68 -sq. ft. for Relax the Back located at 200 Andover
Park East
This decision is based on the Findings and Conclusions listed below.
BACKGROUND
File Number: L04-062, SO4-062
Applicant: Culberston Sign
Request: Approval for a Special Permission Sign, increasing the allowable
sign area. The maximum allowed sign is proposed to be
increased from 18.9 to 22.62- sq. ft.
Location: 200 Andover Park East
Comprehensive Plan Designation: TUC
Zoning District: TUC
SEPA: No determination required
Staff: Brandon J. Miles
FINDINGS
Vicinity/Site Information
The sign being proposed will be located on the west wall of 200 Andover Park East and will face directly
towards Andover Park East. The zoning on the property is TUC and surrounding land uses are
commercial. The exposed building face (EBF) is 378 square feet. With the approval of the Special
Permission Application, the wall sign would be 22.62 square feet (5.9% of EBF) versus the normal
maximum of 18.9 square feet (5.0% of EBF).
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665
• •
Decisional Criteria
TMC 19.32.140(A) allows permitted sign area to be increased by 50% for each doubling of the required
minimum setback...but in no case shall the sign area exceed that permitted in TMC 19.32.150. Pursuant
to TMC 19.32.150, the maximum allowed sign area could be 6% of the exposed building face (EBF) up
to maximum of 500 sq. ft.
The required front setback in the TUC is 15 feet. The building has a setback of 75 feet, 5 times the
required distance.
Per Table 1 of TMC 19.32.140, the standard allowed sign area would normally be 18.9- sq. ft. for an EBF
of 378 square feet. Since the building is setback 5 times the minimum setback required for the underlying
zone, the maximum sign area is allowed to be increased 50% for each doubling of the required minimum
setback up to 6% of EBF or 500 sq. ft., whichever is less. Six percent of EBF (378 -sq. ft.) is 22.68 -sq. ft;
thus the maximum allowed sign area on facade is 22.68 -sq. ft.
CONCLUSIONS
1. The building is setback a sufficient distance to allow an increase in the wall sign area.
2. The proposed sign area of 22.68 -sq. ft is less than six percent of the exposed wall area.
APPEAL PROCESS
This decision may be appealed to the Planning Commission within 14 days from the issuance of this
Notice of Decision. All appeal material must be submitted to the Department of Community
Development. If you wish to appeal this decision, please call the Department of Community Development
at 206-431-3670 to obtain a copy of appeal procedures.
Nora Gierloff, Planning ervisor
Attachments: A. Site Plan, building elevation and sign details
1/7404
Date
- U
City o ukwlla PE:rr jv1 5_'° 14 ' �S,/V�
:94 3 /4 41/R 4-1
b 4 L .u ?o44
Department of Community Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
206 431-3670
PERMANENT SIGN PERMIT APPLICATION
Please print
WAY THe eA K 1O0 4 JOoVER 'PARk-wrlA-( 6 -
Business Name Address of Sign Phone
CUCe SK -4-3 tJ LC <" 520:? 122)-'D ST ItASS 77CoH14 9ggcf y(o. `e°4R • Coo f
Applicant/Contact
Address, City, State, Zip Phone
C�UL120Z7SE (d) .` JZ-�."v �, EAST -Tric c9NA cieLi y6 809,q25•(ad f 1
Contractor Address, City, State, Zip Phone
CHECKLIST
❑ 3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
(/ • Locations of all existing and proposed signs
Sign elevations with area calculations and
dimensions
❑ Building elevations (for wall signs)
❑ Supporting structure and method of illumination
❑ One copy of valid Washington State contractor's license
❑ $100 application fee per sign
See back of form for examples
0
Is your sign a:
❑ Freestanding sign 15 or more feet in height
O Pole sign with face 30 square feet or more in area
O Wall sign weighing 400 pounds or more
If any of the above are true, the application must go through
structural review.
STRUCTURAL REVIEW CHECKLIST:
O $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
O Construction details to describe the proposed foundation
or wall attachments (see back of form for examples)
O Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestandi
Did building go through design review? ❑ Yes
g
❑ No
Wall
WALL SIGNS:.7O
#2
#3
#4
Wall area (length x height) where the sign will b
mounted? (square feet)
37a -
/
/
Sign size(square feet)
£O► 15
4144,72P 1.2,'692-,
Does sign face residential zones or public facilities?/
(Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
N0
IJ 6
Does wall sign weigh more than 400 pounds?(Y/N)
KX)
00
Sign illumination (internal/external/none)
1m -et -oat
t hTeriJ ..C. -
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30
square feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set back
from all property lines a distance equal to their height.
Number of sign faces
.".
INSPECTIONS
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE.
1 HEREBY CERTIFY that the above inform on fum ed by me is true and correct under penalty of perjury by law in the State of Washington, and
that the appli le requirements of the CI i II be . t.0 ' . t !f
FOCI--qZ:c-CoD(
ei
Phone
I —O
Date
of Tu ila
(Sig - ure of owner or authorized agent)
FOR OFFICE USE ONLY
Zoning:
Planning review by:
12 Denied
❑ Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
0 Denied 0 Approved ❑ Approved with conditions
RECEIVED
'AUG 13 2004
commuNITY
DE/EOPIyI NT
Revised 09-17-04
West Elevation
6
•
REL�A I1IEE BACK
1l8:"-_=1 'O"
Sign 1
a
;4
N
:
Nla
N
17'-1 '\)�
13"
8" 5"
Individual lettere Illuminated
with 8500 White neon.
sternal (exposed) rased noway
with tnndonam !aside.
Building fascia.
Total Copy Area: 17.12 x 1.87 a 32.01
Total Sign Area: 32.01 a 32.01 square foot.
Southwest Elevation
r
5209 122nd 8t. lad, Tacoma WA 98446
WA Lia# CULBESS984Mtl
Customers
Address:
12.4"
3.-O"
O
Raceways painted to match the
building color.
13"
5"
Logo panel Illuminated with 6500
White neon. Logo fabricated as a
channel letter with a white
translucent acrylic face 8 blue
logo graphics.
ndivldual letters illuminated
with 6500 White neon.
tenial (exposed) metal raceway
with transformers inside.
Building fascia.
Sign #2:
Total Sign
Area = 22.62
Sales Rep:
Phone:
800.925.6011
Design by:
Landlord Approval:
Date:
Customer Approval:
PLEASE NOTE:
The Information and design
shown In this presentation 1s the
property of Culbertson Slips
Service L.L.C. until released by
safe.
We request that this Information
be kept within the business fee
whirls Is was created and not
released for general use.
RECEIVED
AUG 13 2004
COMMUNITY
DEVELOPMENT
,