Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit S05-042 - FEDEX KINKO'S
FED EX - KINKOS 112 ANDOVER PK E 505-042 • City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 Parcel No.: 0223000045 Address: 112 ANDOVER PK E TUKW Suite No: PERMANENT SIGN PERMIT Permit Number: S05-042 Issue Date: 06/06/2005 Permit Expires On: 12/03/2005 Business Name: Address: Phone: Property Owner: Name: CRIM INVESTMENTS Phone: Address: PO BOX 30182 Contact Person: Name: KIRSTEN HANSON Phone: 206-623-3100 Address: 727 S 96 ST Contractor: Name: HEATH NORTHWEST Phone: 206-623-3100 Address: 727 S 96 ST DESCRIPTION OF WORK: INSTALL A NEW FREE STANDING SIGN "FedExKinko'" Fees Collected: $184.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: N N N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 230 0 Building Height (feet): 18 0 Sign Size (sq. feet): 42 0 Sign Height (feet and inches): 16' 0" 0' 0" Setback (feet): 23 0 Number of Sign Faces: 2 0 Planning Division Authorized Signature: \��\- � Date: b 6 - 0 (9 • 5- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. City Arukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 (206) 431-3670 PER , ANO. 'O S O I a RECEI�( DATE: I MAY 18 2005 PERMANENT SIGN PERMIT APPLUCATION Please print FEDEX Kl Ntcv►s 112 A J o o Iek Nag. -r, i K,,ivlf.4- ? 2//ii-88811 1l eS g 4NDnt &Mori .,wIf abL P 1p - g%OD g 4 -TK No v nun911rit 7 r SEA -Trek 7,W4 20te216 0 Business Name Address of Sign Phone ..Applicant/Contact Address, City, State, Zip Phone Contractor Address, City, State, Zip / 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs alik Sign elevations with area calculations and dimensions jlb( Building elevations (for wall signs) Er Supporting structure and method of illumination - One copy of valid Washington State contractor's license $100 application fee per sign, or 50 cents per sq. ft., whichever is greater. See back of form for examples Phone Is your sign a: [Freestanding sign 15 or more feet in height Pole sign with face 30 square feet or more in area TA/Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: f " $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). Ee Construction details to describe the proposed foundation "Sr wall attachments (see back of form for examples) tructural calculations for the sign shall be prepared by a Washington State structural engineer [eister cto tea, SIGN DESCRIPTION How many signs will list this business? Freestanding / Did building go through design review? 0 Yes No Wall WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) Sian size(square feet Does sign face residential zones or public facilities? (YIN) Exposed neon tubing is not allowed within 200 fee LDR, MDR or HDR zones. Does wall sin re than 400• ounds? /N) Ination internal/external/none) . FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed er remises. 23 O Height of building (feet). Generally, signs may not be higher than the building with which they are associated �8'3- ,3 „ Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area 4/2,/0 Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. /6 ' Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. 23, Number of sign faces Z. INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing Inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural -inspection is -required for ail signs when instailation is compiete. The appiicant or installer is required to caii the Planniny Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law In the State of Washington, and that the applicable requirements of the City o 1Tukwila will be met. Date (Signature of owner or authorized agent) Phone FOR OFFICE USE ONLY Zoning: Structural review required? Planning review by: O Denied Issued 0 Issued with conditions No Structural review by: O Denied Approved 0 Approved with conditions • � State of Washington DEPARTMENT OF LABOR & INDUSTRIES PO BOX 44450 OLYMPIA WA 98504-4450 HEATH NW INC 727 S 96 ST SEATTLE WA 98108 •.t.k G =.I ice.. }''�'Q � 4— 4.. •� DL'Y PtDF , WA . FIRST CLASS MAIL US POSTAGE PAID 1 gRSINAPY12 RECEIVED MAY 18 1005' DDEIOPMENT 11t11ll!ltt1111111111111111iin t(tttti,l,tltlttlIIItti1tltft! Detach And Display Certificate DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED':'AS PROVIDED BYLAW AS CONST.CONT `SPECIALTY . `- L'77— aaay -•- v , REGL„�,STdd�Y # `VEXP'. DATE CCCIBC.HEATHNI981JE:,04/05/2006. =EFFECTIVE •DATE ' =-- L--04/05/2002 .HEATH - NW INC SEATTLE •WA' 98108 F625-052-000 (8/97) Detach And Display Certificate REGISTERED AS PROVIDED BY LAW AS' CONST CONT SPECIALTY REGIST. # EXP. DATE CCCIBC-HEATHNI981JE 04/05/2006 EFFECTIVE DATE 04/05/2002 HEATH --NW INC 727 S 96 :ST :•., SEATTLE WA 98108 Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES Please Remove And Sign Identification Card Before Placing In Billfold • • Subject: Freestanding Sign FedEx Kinko's 112 Andover Park Tukwilla, Wa. To Building Official for Permits. RECEIVED 'MAYO 18 20051 DCOfyMUNITy, FedEx Kinko's is proposing that a new sign to go on their existing 8" round pole which sits 29' back from the property. There is an existing non -conforming sign on the pole at this time. The existing sign is 4'3" tall by 17'6" long and is 20'6" to the top. Our proposal is to reduce the overall height from the existing 20'6" to 16'. Also, to reduce the size of the sign to 3'7" X 11'9". The existing pole and footing were designed for the larger sign and will hold the smaller sign without engineering. The tallest part of the building structure is 18'3" The leading edge of the new sign will be 23' back from the front property line. 3' from the north property line. Existing power at pole will be used to illuminate the new sign. See attached detail booklet furnished by FedEx Kinko's for details. Thank you David DeFrank Heath Northwest Inc. 206-6233100 9 L J PIM _r) 0 KNKO'S#5173 112 Andover Park East. Suite A TUKWILLA, WASHINGTON 98188 TgIDYg SIGN COMPANY MILE OCA ©Or4C G` UZ COVER SHEET MAP CODE CHECK SIGNAGE PROPOSAL SITE PLAN RECEIVED MAY 18 2005 COMMUNITY DEVELOPMENT 8" PIPE Office and Print Center SIGNAGE PROPOSAL: 1. REMOVE & DISPOSE OF EXISTING CABINET AND CABINET SUPPORT CABINET. 2. INSTALL (1) ONE D/F FXCAB-42 SIGN CABINET. (3'-7" x 11'-9" CABINET) 3. PAINT SUPPORT STRUCTURE FEDEX PLATINUM SILVER. 4. OVERALL HEIGHT MUST BE 16'-0", EXISTING SUPPORT STRUCTURE WILL NEED TO BE CONFIGURED FOR THIS HEIGHT. DECE=IVED MAY 18 2005 COMMUNITY DEVELOPMENT PROPOSAL SURVEY - SIGN ASSEMBLY 3'-7 " 16'-0" 11'-9 " Knk Office and Print Center PYLON SIGN STRUCTURE ELEVATION SCALE: 3/8"=1'-0" RECEIVED MAY 18 2005' COMMUNITY EVELOPMENT PROPOSAL SURVEY aLL-' T LA a 2005 n.t.s. KINKO'S i1?3 loop 0 D c STOREFRONT I 1 ANDOVER PARK EAST PYLON SIGN STRUCTURE CHANNEL LETTERS Scale: RECEIVED { MAY , 18 COMMUNITY DEVELOPMENT /E - //.2 /ONO /-iQ..e.K E . .Su -ATE 4 -.R.EceNE° MAY 18 2005' D1 3'7"x //'y" /42/i9POSEo .c/E�c/ S/GN OA, EX/57%Jt5• Po/c /4N0 A.D0r; 40$ 23' /�Elc/.oLK. oF4 J I /7iG4,N rE.e. /47' %4LL 4 -sr P/4/2T of 231-4,4 = /O'S" 6)t/37 -/NG S/Gw/ 5/0Blv.�cK fy/'.933 . 230' it 1