Loading...
HomeMy WebLinkAboutPermit S05-064 - ULTAULTA 17320 SOUTHCENTER PY S05-064 City oftkwila • Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 PERMANENT SIGN PERMIT Parcel No.: 2623049079 Permit Number: S05-064 Address: 17320 SOUTHCENTER PY TUKW Issue Date: S/2,3/Zo-p 5 Suite No: Permit Expires n: 2.123/2-00(P Business Name: ULTA Phone: Address: 17320 SOUTHCENTER PY, TUKWILA, WA 98188 Property Owner: Name: KIR TUKWILA LP Phone: Address: 4055 FACTORIA MALL SE, PO BOX 5787 Contact Person: Name: Address: Phone: Contractor: Name: OLYMPIC SIGN SERVICES Phone: 360-402-0986 Address: 2702 12TH AVE NE DESCRIPTION OF WORK: One wall sign 78.93 SF: 'Ulta' Fees Collected: $184.00 Zoning: TUC Sign Type: PERMANENT SIGN: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 2910.25 0 0 0 Wall Sign Size (sq. feet): 78.93 0 0 0 Sign Lighting: Face Residential Land: N N N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0' 0" 0' 0" Setback (feet): 0 0 Number of Sign Faces: 0 0 Planning Division Authorized Signature: i;07,4,4 Date: g/23 /Zo--o 5- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: Permsign S05-064 Printed: 08-23-2005 • • SITE INSPECTION (PLANNING) File No. S05-064 Name of Tenant: ULTA Sign Address: 17320 Southcenter Parkway Date Photo Taken: 11-02-05 x Comments: Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of Make new site visit and take photo by 4/19/2006. • INSPECTION RECORD 1� f Retain a copy with permit INSPECTION NO. PERMIT NO. S CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 Prct 0A --p Type of Ins tion: Addre c./1(�J D 1 1 7/0/• Date Called: 1 O Zg f b5" ^ Special Instructions: /Date Wante / m' lPio_9(os Requester: /��uC" Phone No: (ei0 " q0 2_ —C2v'10 giApproved per applicable codes. d1s8, Corrections required prior to approval. COMMENTS: Date: �2/ S El $58..'60 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: City oi'ukwila RECEIMA C-06 Department of Community Development 6300 Southcenter Boulevard, Suite 1001AUG l refle5 ?//9/200 Tukwila, Washington 98188 206 431-3670 DEVELOP., PERMANENT SIGN PERMIT APPLICATION w TUKWILA COMMUN. , (JL— %A -- Business Name Please print $� / 1 3 Z c) `� (-E, c.a,e – I�kw l Address of Sign 9 ss -06 i A.,Are.,..1 c.a,n„_......a.... 27O 12.F`' A-vk_ kJ Dly.n1:`,x, LvA- ApplicanUContact Address, City, State, Zip (- Contractor Contractor 2.702 121-41AJcA/1_ (0/I,/W - TRS" -o6 Address, City, State, Zip Phone 563 b2—33S Phone 360,i02..-6 3 Phone CHECKLIST O 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs O Sign elevations with area calculations and dimensions O Building elevations (for wall signs) O Supporting structure and method of illumination O One copy of valid Washington State contractor's license O $100 application fee per sign See back of form for examples Is your sign a: ❑ Freestanding sign 15 or more feet in height O Pole sign with face 30 square feet or more in area ❑ Wall sign weighing 400 pounds or more K any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: o $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list this business? Freestanding Did building go through design review? Yes 0 No '? Wall WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) I / 61— 5,/ Sign size(square feet) 7 i . fq s.0 Does sign face residential zones or public facilities? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. NI 0 Does wall sign weigh more than 400 pounds?(Y/N) Sign illumination (internal/external/none) 14t«..a1 FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of sign faces RECEIVED ?AUG '1 9 2005 COMMUNITY DEVELOPMENT INSPECTIONS If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information fumished by me is true and corned under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila will be met. g- Date (Signature of owner or authorized agent) 31:,cD C/ 63I0 Phone FOR OFFICE USE ONLY Zoning: Planning review by: 0 Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes 0 No Structural review by: v%,,(4 Lov\(....eindt 0 Denied Approved 0 Approved with conditions RECEIVED AUG 19 2005' COMMUNITY DEVELOPMENT DEP•TMENT OF LABOR AND INDUST* LICENSED AS PROVIDED BY LAW AS ELEC CONTR SIGN L= I ,C*.EN§E#'1"" EwX�P�. DAxTE EC'0 4 OLYMmPS.S 9 7 2°R9' !.fi r.2 9,% 2 0 0 5'- EFFECTIVE 'DATE' 12/'29`%2003 OLYMPIC SIGN SERVICES LLC 2702 I2TH AVE NE OLYMPIA WA 98506 F625-052-000 (8/97) RECEIVED AUG 191005 DtvE Opmy T UbleY2/1A1U2 425640525 Kimco Realty Cor ration muummourammi eolazA DATE: fidgi2005 TO: Robert Fehlman COMPANY: Kieffer & Co_, Inc. ADDRESS: FACTURIA MALL PAGE 01/03 • • TRANSMITTAL SHEET PHONE: 847-520-1255 x 246 FAX: 847-520-1543 FROM: Bill Brown, Director of Development 0 Eric Dumas, Director of Construction 2 Leann Hopwood, Property Manager ❑ Terri Meagebu, Property Administrator O Jennifer Netherda, Office Assistant REGARDING: ULTA - Parkway SuperCenter TOTAL PAGES (including cover sheet): _ COMMENTS: 0 Urgent [J Fax 0 Normal Importance 0 Mail 0 Please Reply ❑ Courier 0 FYI ❑ Pick-up 0 Other: Attached is the approval for the ULTA sign at Parkway SuperCenter. P,O.BOX 5787 ECEIVED AUG 19 2005 COMMUNITY DEVELOPM. Bellevue, WA 98006 Tel: 425-641-8282 Fax: 425-649-0529 118-b' UL -6O 60" Illuminated Letters w/ Tag Line. Cabinet 67-5' / F • STOREFRONT ELEVATION J / / SPECIFICATIONS: Referencefaixication drawing 845468 For construction 8cora spec'd'icalicos. scde:Y= L' -D - 9 N m0aw%awess,sxZ i11aa9pRq Dv a®9Yu6e[[1441Ntsa142®,11®3114 4 ZSIW KIHPPEn 4100..174.0. WI rod 1b-(uels:Yrq IL -tato MIL I WI 5211-1231 ra Mai 421,117+! 51wtr jo1ln7fl7aa.tas wnarIA: ULTA LemmO& Pena/SI puturtrr,1itth •xA thEViIY: l0. otpIAtR: 71W oat Si9M USIF I PRODUCNORPROM t416 -alt •are •wa 1.4 ;3.1414.14.4 B51377 RECEIVED AUG 19 2005 COMMUNITY DEVELOPMENT Z00Z/Z0/50 6Z506b95Zb 17bW VIelOiO'. -o D m cc 0.) ILUA LAYOUT/DIMENSIONS WHITE FACES - Internally illuminated Letters / Tag Line Cabinet G U B SALMI •COS119E1tCS1EttAGR NCE F D E Scale. tYT.S_ G 30" 3d" 4 7/3" 6W 8' TAG LJl'•E CABINET SPfQf9G2110t8: T7io Pag 5ru .rliwtto b4. a afrucMAd dray ba en i6c.,:nvl„d k h - SEE LETTER C1EC)Qt I{S hef 103>. 07328 White Pfailghe WA:* oat 91. MI -3113O•22 Elloak Yi71 Ym geld Lit su r<onn a: o b'arz,nd 414 ilia {[qui)p. b b hand-mArl i'(ii' IE wooded out f-tio #n Rod63ranai Uri Itheninctian ro E , Kiit, of :e1 a64 b mavdcin Sgfe mbr.sy b. cokr mulching the lotoom Traxfomrar5 la bo remniari L»h'ud w I ].bunt olri+al R+. -,J, so faitia vat,' ER}ii Lrpe mx»rrjmrdrvl. EibriOlEci Nater: Ca6ii144 l+emm: b 6t. REodr Foam! ref ?Ca c Tim top TeMulrr . I REMOTE F- LETTERS 0. ti g .E CI,...', fr ii.17.,..J., II P.10 ill ' - - ''.\-311 ' 0 ri'E1le CCYCR i165DOJKS 1 i E 1 Di& 15i -rt CFACE THIC]]4TSS 3116- 1 COUR 4'7329 MITE 1 vein P1 «.4r2<-rtav o-rfi s 1 CQI.R ELI -cc FK -0..w I GSV:~ 5.3- F _wo Phri.OAT COL BINE: 37E 1- TAzcR BLACK 1 TYPE Tait CA? EGGS RAMOL ALU'rrue 1 6a?c .06.1 i@Tte.E SF PcaT TYPE GLASS I .OT. 1 376' T,7AHgCR1IER TI E. 371.N6.1:D 1 nx 60 7{'CNER 19S1F0SAL N.A. 1 FIT. ria. SEVENS 512E BL - I/2- Fa1PJ_FS OD. 1 COLOR TO HATCH TRIYCAP el MIHNrIRG 1NTUNAL I/4' RMI7AIT EiTEi7iAL 114' Tl#Ad® RDD VSIJIATEO BOOT sTAPRIA.an 0 GTO 9_06vE WW..4TJ7 STA7k3AR9 SIO -1 TI TYFE GSC000ECTI77_LE T ;COTE CT SnnGy iCa]E0:F.t1[l en 111 ..111 SECTT•CL' O -TS J'CAT10 FLR Pal -VAT 04 1131lr_ .L GLI1:OC 2 our CtU T t coi .1� 013Na' nn.a •tuu R...,Fn IL LCTs� & ca., INC.. O 2092 wEFFEf a co. Iran. It/ 7'WM I, dal lat. 71IIR 5712E-1417 7RIA 11111172•i7I1 ESI: LE M01.731i verNSJaflAri l melm PR0111JCTIDE YA0CE351b16 lei -791 -777 .101 a]T 4 iJ C < •� 41444141 COMMUNITY DEVELOP/MEW! 7,007,/7R 'GR 01 m 6Zg©6b95Zb 11t'W VIWIJt1A m t+r�urll III r f ! °: III � I dNl %�I II{ �4Ilp 11 II IMr%1 III Ili HP I %I ,I,'u Iw I il� %9 i�'�i} 9VIp II I Ip"�'iNlll 4 h%I IUVI I :I"" Ir N I NI'.:uNr IIIVI M III rt,'�f'VNII I I w I ,11.' u" a YII '.�:I I II Y I Iru:: I,% %'� I h h 51 I:�:� .IIUI,:I��:II�P� +4 �I�I�,�lG,1,llrudl��.��ll�:„:,,�"NIIIIyPId hVt"Iu:m�:VVWMlllln�m „dl„I::IkHd IIS Il,:,.ulhhl hlPuPyWI,,i::Y:II,. ,qP hywllriV,N�PhM Ja���ko,a:�l IIIu�fiVV�1wR�l,a:�..�1�da .�:�:�lau:l,Lll � }I r ti:,,,. W IV Prlhl�,u�,�ir:4ull» Ifghl�l�k„�I:I,I:VIa"IY�411RIVII� ,:wpar:u.. 050 PD: 12705 Thomasville David's Bridal Tony Ethan Romas Allen Kimeo -{ealty Corporation JoAnn Borders OfficeMax Linens N Things Petsmart Fabric Books Home Depot Expo 1125105 KIR Rece ED 'AUG 19 1005 Z�OUNITy ►T 10/ 10 1 Ip L-_Jp :d STOREFRONT ELEVATION 116' - 5" ULT4 60 60" Illuminated Lei f e s w/ Tag Lune Cabinet 62'-5" / / %/ / / 9 N SPECIACA11ONS: Reference fabrication drawing 645468 For construction & color specifications. Scale: 3/32" = 1'- 0" RECENED AUG 19 2005 cotiliGUNITY oVELOPMEtaT J 101S IS AI OIIBIWAl ORmRnim MAMBA 501RIQD PoI ISE 01 COOD((n010e1 A MUM ISIS NAMED WI TOO II 110111 CIL OKA O RI TO IE 05t000es COPIED 01 MIMEO 11 AR 1111101 IM10111 IR 001181 PEIRSS10101 PAR m (0.11C. O� 2005 OGAIE0=IFIECRI 4$ CO'-, 0lNC. 585 Bond Street - Lincolnshire, IL- 60069 PHONE: (847) 520-1255 FAX: (847) 520-1543 www.kieffersigns.com CUSTOMER. ULT A LOCATION. Parkway Supercenter, Tukwila, WA SALESMAN. L.C. DESIGNER- MAK DATE: 5/9/05 . pone - ID PRODUCTION PROCESSING Job # -001 -002 -003 -004 0 N CO CD IA41+1444441 LAYOUT/DIMENSIONS WHITE FACES - Internally Illuminated Letters / Tag Line Cabinet C A E \v/ G 1-1 SALON•COSMETICS•FRAGRANCE F U LTA 18" 24" 30" 36" 42" 48" 54" 60" 72" A B .3%-..2-15/1t C 01/1 2'= 8 +5/8" D E 2' 6 3'-0" 4'-0" 5'-0" 5'47/8' 6'-5 7/8" r-4 8'-7 7/8" 87/81? 10'-9 3/4" • 12'-11' 3/ 4'-0 7/8" 5'-5 1/4" 6'-9 h/2" '-1:3/ 6'-1 1 3/4" -1 5 9'-3 5/8" 11'-7 Y2" 13'-11 3/8",, 9 '/s" 111/I 1'-0 3/4" F 5/8"` 321%4"'. 4" 4 5/8" ' 5 1 /4" 1'-3 7/8" 6 Y/2" 7/8" Scale: N.T.S. 27/1.6" 4 7/8" 61/2" 71/4 8" ,9 3/4 TAG UNE CABINET SPECIFICATIONS: The tag line cabinet to be constructed similar to an illuminated letter - SEE LETTER BOX SPECIFICATIONS. The face to be #7328 White Plexiglas w/ flat cut 3M #VT4-3630-22 Bladc vinyl film applied 1st surface as a background field. The logotype to be translucent White weeded out from the badcground field. Illumination to be White neon tube to maintain light intensity & color matching the letters. Transformers to be remoted behind wall. Mount cabinet flush to fasda using Hilti type masonry anchors. Fabrication Note: Cabinet returns to be Black precoat w/ Black trim cap retainers. -1 REMOTE LETTERS l" -- C rill ih IB �ununu»umuI'nua"° N E G NMI. H ''min L I le I aft J K Q NEON COLOR #65.00/KS WHITE DIA. 15MM 43 FACE THICKNESS 3/16" COLOR #7328 WHITE VINYL NA 0 RETURN DEPTH 5" COLOR BLACK PRECOAT GAUGE 5.3" x .040 PRECOAT COIL n `1 RETAINER SIZE I" COLOR BLACK TYPE TRIM CAP BACKS MATERIAL ALUMINUM GAUGE .063" 0 TUBE SUPPORT TYPE GLASS 1 HGT. I 3/4" © TRANSFORMER TYPE STANDARD 1 MA 60 O KICKER MATERIAL N.A. HGT. N.A. O SCREWS SIZE #4 - 1/2" PHILLIPS HD. COLOR TO MATCH TRIMCAP © MOUNTING INTERNAL 1/4" RIVNUT EXTERNAL 1/4" THREADED ROD A INSULATED BOOT STANDARD © GTO SLEEVE INSULATED STANDARD 0 SWITCH TYPE DISCONNECT/TOGGLE •SPST DISCONNECT SWITCH LOCATED BEHIND WALL. •ALL ELECTRICAL OUTS LOCATED FOR RACEWAY OR REMOTE APPLICATION. '2 WEEP HOLES PER LETTER REQUIRED (3/8" DIA.). •CAULK REQUIRED. 0 LISTED r � r.. d► IL II V IG ILJ' G 1 g 2005 COMMUNITY DEVELOPMENT Etc C0_,INC_ ren 5 u 056111501POYI09 020816 005010510 101 01 0 11 10010(101 0(11 WO HMG !11108 9t,OI O 55E9110: 0L 5 5 0009 rt tlr110108, WHO 01 EIBIRE11111111 821101 r0100181E 0559 01011 010& 5069110.111 ® 2002 KIEFFER 8. CO. INC_ 3322 Washington Ave. Sheboygan, WI. 53082-1087 PHONE: (920) 458-4394 FAX: (920) 451-8880 www.ldefterslgns.com CUSTOMER. ULTA LOCATION. VARIOUS SALESMAN. L. C. DESIGNER. ETD DATE: 4/25/02 LISTED -fE 1$01 PRODUCTION PROCESSING Job # -001 -002 -003 -004 N CO CO CO ]C NC 0 C-3 CD -- a> V CD CO E m CD N - •O NC•- . CO ... O CD MAK 10/22/02 14101©c©aa 645468