Loading...
HomeMy WebLinkAboutPermit S06-010 - SPRINTSPRINT 17430 SOUTHCENTER PKWY S06-010 Sign Permit City of1)ukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431-3670 PERMANENT SIGN PERMIT Parcel No.: 2623049110 Address: 17430 SOUTHCENTER PY TUKW Suite No: Permit Number: S06-010 Issue Date: 02/10/2006 Permit Expires On: 08/09/2006 Business Name: SPRINT Phone: Address: 17430 SOUTHCENTER PY, SEATTLE, WA 98188 Property Owner: Name: MBK NORTHWEST Address: 7690 SW MOHAWK ST Contact Person: Name: CONNIE GUFFEY Address: 909 S. 28TH ST. Contractor: Name: PLUMB SIGNS, INC. Address: 909 S. 28TH ST. Phone: Phone: 253-473-3323 x10 Phone: 253-473-3323 DESCRIPTION OF WORK: SPRINT WALL SIGNS (25.63 SF each). Fees Collected: $200.00 PERMANENT SIGN: Zoning: TUC Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 1762 877 0 0 Wall Sign Size (sq. feet): 25.63 25.63 0 0 Sign Lighting: Face Residential Land: N N N N Freestanding Sign #1 Freestanding Sign #2 Street Frontage for Entire Lot: 0 0 Building Height (feet): 0 0 Sign Size (sq. feet): 0 0 Sign Height (feet and inches): 0' 0" 0' 0" Setback (feet): 0 0 Number of Sign Faces: 0 0 Planning Division Authorized Signature: Date: 2//b /2_0D {m I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: Permsign S06-010 Printed: 02-10-2006 SITE INSPECTION (PLANNING) File No. S06-010 Name of Tenant: Sprint Sign Address: 17430 Southcenter Parkway Date Photo Taken: 05-03-06 x Comments: Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of Make new site visit and take photo by 11/03/2006. South Elevation East Elevation J aNNILA 1908 SPRINT City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite 100 DATE: Tukwila, Washington 98188 206 431-3670 PE•NO. //� ` TUKWILA :I � f FEB 0 3 1006 OCEyELOPNtTY PERMANENT SIGN PERMIT APPLICATION Business Name Connie Guffey Applicant/Contact Plumb Signs Inc. Contractor Please print 17430 Southcenter Parkway Address of Sign 909 S. 28th St., Tacoma, 98409 Address, City, State, Zip Phone (253)473-3323 x10 Phone 909 S. 28th St., TAcoma, 98409 (253)473-3323 Address, City, State, Zip Phone CHECKLIST 3 sets of plans (dimensioned and scaled), including site plan showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs Sign elevations with area calculations and dimensions ' Building elevations (for wall signs) Supporting structure and method of illumination One copy of valid Washington State contractor's license $100 application fee per sign See back of form for examples Is your sign a: O Freestanding sign 15 or more feet in height O Pole sign with face 30 square feet or more in area O Wall sign weighing 400 pounds or more If any of the above are true, the application must go through structural review. STRUCTURAL REVIEW CHECKLIST: ❑ $84 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wall attachments (see back of form for examples) ❑ Structural calculations for the sign shall be prepared by a Washington State structural engineer SIGN DESCRIPTION How many signs will list thls business? Freestanding_ _7-8 Did building go through design review? ❑ Yes 0 No Wall. WALL SIGNS: #1 #2 #3 #4 Wall area (length x height) where the sign will be mounted? (square feet) 1/762 $ 7 7 Sign size(square feet),S_.4& 3-‘ ,,3 KOilogv Does sign face residential zones or public facilites? (Y/N) Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR zones. C72 •Ve GtttuwtL¢ No No 5r.) Does wall sign weigh more than 400 pounds?(Y/N) No No Sign illumination (internal/external/none) Int Int FREESTANDING SIGNS: #1 #2 Street frontage of the entire premises where the sign will be located (feet). Generally, only one freestanding sign is allowed per premises. Height of building (feet). Generally, signs may not be higher than the building with which they are associated Size of sign face (square feet). Structural review is required for pole signs with faces 30 square feet or more in area Sign height (feet -inches). Structural review is required for signs 15 feet or more in height. Distance from closest edge of sign to property lines (feet). Generally, signs must be set back from all property lines a distance equal to their height. Number of sign faces If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for footing or bracket inspections. Footing Inspections must take place before concrete Is poured. Bracket inspections must take place before sign is installed. A structural inspection is required for all signs when installation is complete. The applicant or Installer Is required to call the Planning . Division at 431-3670 for a final inspection. It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and Industries at (206) 248-6630. SIGN PERMIT APPLICATION IS VALID FOR 180 DAYS AFTER ISSUANCE. I HEREBY CERTIFY that the above information furnished by me is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila tyi I be met/ �6•(253)473-3323 x10 Date (Signature o owner or aut • i .i age pj• j Phone Zoning: Planning review by: O Denied 0 Issued 0 Issued with conditions Structural review required? 0 Yes ❑ No Structural review by: O Denied 0 Approved 0 Approved with conditions RECEIVED FEB 0 3 2006 COMMUNITY DEVELOPMENT [LA e f#�� r� I ----S;.-1613th si ; : �_ S 160th- `- 7 T -S -162nd -St TL _ t .} a '¢-----•-- S 1.64th�5t 5 -166th St- N .. .p6 ( yr -4 --Am E - +5 -172nd -St L s®2 os tdurosoRCop ;€200AM!WtEQ-adforGOT.loc. SOUTH CENTER PARKWAY E01 E02 RECEIVED SEP 2 6 2005 Co mmuNITY EVE DEVELOPMENT 0 11011.411 0114 ASIO0*TIal MEMBER A MEMBER OF Iime CUSTOMER APPROVAL Customer Signature Date COPY, COLORS 8 SIZES SIGNTECH does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! Customer Signature This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. Date �icjntech Job Name: SPRINT #524 Date: 8/23/05 REVISIONS Drawing No. 05-01112 Address: 17430 Southcenter Parkway A A (ELECTRICAL ADVERTISING, INC. 4444 Federal Blvd. San Diego CA 92102-2505 Phone: (619) 527-6100 Fax: (619) 527-6111 City, State: Tulwila, WA 98188 A 0 Salesperson: Art Navarro Project Manager: DIANE BREVARD A A Drawn by: Christy Rust ScaleAS NOTED 0 Sheet:1 Of:3 SIGN SHEDULE REMOVE AND DISPOSE OF EXISTING SIGNAGE PATCH AND PAINT FROM BREAK TO BREAK USING 385 A SAND PIPER INSTALL NEW SP24Y REMOVE AND DISPOSE OF EXISTING SIGNAGE PATCH AND PAINT FROM BREAK TO BREAK USING 385 A SAND PIPER INSTALL NEW SP24Y PROPOSED NEW SOUTH (STOREFRONT) ELEVATION SCALE: 3/32" =1'-0" EXISTIN IGNS EXISTING SOUTH (STOREFRONT) ELEVATION EN EXISTING EAST ELELVATION MEMBER CUSTOMER APPROVAL SIGNTECH does NOT provide primary electrical to sign location - RESPONSIBILITY OF OTHERS! IAI9AAlIO At SIE! COMM Customer Signature Date Customer Signature Date COPY, COLORS It SIZES This design is the exclusive property of Signtech and cannot be reproduced in whole or in part, without their prior written approval. ELECTRICAL ADVERTISING, INC. 4444 Federal Blvd. San Diego;, CA 92102-2505 Phone_(619)d527-6100 Fax(619)527-6.111 Job Name: SPRINT #524 'SEP Address: 17430 Southcenter Parkway cod b 1005 D �VAII GELD �AlT PROPOSED NEW EAST ELEVATION CALE: 3/16"=1'-0" �I etc City, State: Tulwila, WA 98188 Salesperson: Art Navarro Drawn by: Christy Rust Date: 8/23/05 Drawing No. 05-01112 Sheet:2 Project Manager: DIANE BREVARD ScaleAS NOTED Of:3 7 1/4" - 3" 4 Y4" .040" ALUMINUM RETURN PAINTED TRIMCAP 1/2" #8 SCREWS MIN 4 P ER LETTER SCALE: 1/2" =1'-0" SQ. FT: 13.8 .177" #7328 PLEX FACE WHITE LED'S .090" ALUM. BACK POWER SUPPLY DISCONNECT SWITCH TO BE WITHIN SIGHT OF SIGN POWER SUPPLY RACEWAY #10 X 2'/2" SCREW INTO #10 ANCHORS @ 24" O.C. TOP AND BOTTOM PRIMARY ELECTRICAL MANUFACTURE AND INSTALL TWO (2) SETS OF INTERNALLY ILLUMINATED PLEX FACE CHANNEL LETTERS FACES: .150 #63260 YELLOW ACRYLIC TRIMCAP : 1" JEWELITE PAINTED TO MATCH OPAQUE METALLIC GREY 3M# 3650-221 VINYL. BACKS :.090" ALUMINUM RETURNS :.040" x 5" DEEP ALUM. COIL PAINTED TO MATCH OPAQUE METALLIC GREY 3M# 3650-221 VINYL. ILLUMINATION: 15MM 6500 WHITE NEON WITH 60MA TRANSFORMERS AS REQUIRED FOR PROPER ILLUMINATION. ATTACH FLUSH TO FASCIA AS REQUIRED. ELECTRICAL REQUIREMENTS FOR NEON ILLUMINATION As required by standard #2161 , Signtech Electrical Advertising, Inc., exclusively uses secondary Ground fault -Interrupted (GFI) transformers. Each Sign MUST have: - A dedicated branch circuit - Three wires : Line, Ground, and Neutral. - Wire Size : Min 12 GA THHN Copper Wire. NOTE: The gauge of the wire is dictated by the length of the run & amperage as per NEC Article 300. - The ground wire must be continuous & go from the sign to the panelboard ground bus. - Voltage between ground and neutral should measure no more than 3 volts. - Power to the sign must be done by a licensed electrical contractor or licensed electrician. WEEP HOLES REQUIRED ONLY FOR ALL EXTERIOR INSTALLATIONS U.L. APPROVED INSTALLATION DETAIL: CHANNEL LETTER WITH LED ILUMINATION 1'/2"=1'-0" ELECTRICAL„ ADYERTISING, INC. Job Name: SPRINT #524 Address: Date: 8/23/05 , '. J?S 1 0 N S' Vu Drawing No. 05-01112 17430 Southcenter Parkway City, State: Tulwila, WA 98188 Sheet:3 Salesperson: Art Navarro Project Manager: DIANE BREVARD Drawn by: Christy Rust ScaleAS NOTED