Loading...
HomeMy WebLinkAboutPermit S06-060 - ADVANCED CARE DENTAL CENTERADVANCED CARE DENTAL CENTER 16600 WEST VALLEY HWY S06-060 SIGN PERMIT City (*Tukwila • Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMANENT SIGN PERMIT Parcel No.: 2523049085 Address: 16600 WEST VALLEY HY TUKW Suite No: Steve Lancaster, Director Permit Number: S06-060 Issue Date: 01/09/2007 Permit Expires On: 07/08/2007 Business: Name: ADVANCED CARE DENTAL CENTER Phone: 425-251-6044 Address: 16600 WEST VALLEY HIGHWAY , TUKWILA, WA Property Owner: Name: AULAKH BUTTAR & CANTOR LLC Address: 15701 138 PL SE Contact Person: Name: APOLLO NEON, INC. Address: 9800 HARBOUR PLACE, SUITE 208 Contractor: Name: Address: Phone: Phone: 425-349-5044 Phone: DESCRIPTION OF WORK: One freestanding sign for Advanced Care Dental Center and Immigration Lawyers. Fees Collected: $115.00 PERMANENT SIGN: Zoning: C/LI Sign Type: Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4 Wall Area (sq. feet): 0 0 0 0 Wall Sign Size (sq. feet): 0 0 0 0 Sign Lighting: Face Residential Land: Street Frontage for Entire Lot: Building Height (feet): Sign Size (sq. feet): Sign Height (feet and inches): Setback (feet): Number of Sign Faces: Freestanding Sign #1 196 18 32 10' 0" 16 Planning Division Authorized Signature:: ! Freestanding Sign #2 0 0 0 0' 0" 0 0 o.,. ll1 ) 37 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS FROM THE LAST INSPECTION. doc: SIGN -PERM S06-060 Printed: 01-09-2007 City of Tularila Steven M. M.Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ci.tukwila.wa.us Parcel No.: 2523049085 Address: 16600 WEST VALLEY HY TUKW Suite No: Tenant: APOLLO NEON INC Steve Lancaster, Director PERMIT CONDITIONS Permit Number: S06-060 Status: ISSUED Applied Date: 10/20/2006 Issue Date: 1: THE PROPOSED DETAILS SHOW THAT WOOD MONSTERS WILL BE LISTED ON THE FREESTANDING SIGN. WOOD MONSTERS ALREADY HAS TWO WALL SIGNS (THESE SIGNS HAVE BEEN INSTALLED WITHOUT PERMITS). TMC TITLE 19 PERMITS TWO SIGNS PER BUSI THE INCLUSION OF WOOD MONSTERS ON THE FREESTANDING SIGN WOULD GIVE THE BUSINESS THREE SIGNS. WOOD MONSTERS CANNOT BE LOCATED ON THE FREESTANDING SIGN. **continued on next page** doc: Conditions S06-060 Printed: 01-09-2007 City of Tulila Steven M. Mufayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or regulating construction or the performance of work. Signature: Steve Lancaster, Director as outlined. All provisions of law and ordinances cancel the provision of any other work or local laws Print Name: c�Z Date: doc: Conditions S06-060 Printed: 01-09-2007 SITE INSPECTION (PLANNING) File No. S06-060 Name of Tenant: Advanced Care Dental Center Sign Address: 16600 West Valley Hwy Date Photo Taken: July 13, 2007 Comments: Sign appears to conform to permit application Sign appears different from permit application Sign not installed as of 7/13/2007 Make new site visit and take photo by 12/06/2007 • FAX TRANSMITTAL City of Tukwila Department of Community Development Fax Number: (206) 431-3665 e-mail: ngierloff@ci.tukwila.wa.us TO: Leona Hansen DATE: 11/3/06 DEPT/TITLE: FROM: Nora Gierloff COMPANY: Apollo Neon TITLE: Planning Supervisor FAX NO: (425) 349-5045 DEPT: Community Development PHONE (425) 349-5044 Total pages transmitted, including cover sheet:: 3 RE: Advanced Care Dental Center Sign COMMENTS/MESSAGE: Tukwila has a requirement that freestanding signs that are between 3 and 10 feet in height may not block vision within 40 feet of the intersection of a street or driveway, see attached diagram. The photograph submitted with the Advanced Care Dental Center sign permit does not have enough detail to demonstrate that this requirement has been met. Please submit a scaled site plan showing the curb line, property line, sign location and clear vision triangle. If you have any questions please call. IF THIS COMMUNICATION IS NOT Nora Gierloff at (206) 433-7141 CLEARLY RECEIVED, PLEASE CALL: Dept. of Community Development - 6300 Southcenter Boulevard, Tukwila, WA 98188 - (206) 431-3670 SERVICE STATIONS FREESTANDING SIGN Each station is allowed one (1) lighted, double-faced sign with a maximum. area of 75 square feet per side. The maximum sign height is 35 feet, unless it is within 1,000 feet of a freeway interchange and special permission for a taller sign is granted. The sign may only be lit during business hours. WALL SIGN One illuminated wall sign, which cannot be larger than 20% of the exposed building face to which it is attached, is allowed for each street frontage. OTHER SIGNS Each station is allowed two (2) unlighted, non-portable, double-faced signs not larger than 20 square feet per side. Permanent signs at each pump island listing the type of fuel, price and service available and signs on rolling merchandise racks are allowed without permits. HOTELS WALL SIGNS One wall sign which contains only the hotel name and logo, is allowed on each building face. A hotel may not have more than four (4) wall signs unless it has a restaurant in the hotel building in which case it will be allowed one (1) additional sign. The restaurant sign will share the area allowed in the Maximum Wall Sign Area Table, may contain only the restaurant name and must be placed on the ground floor wall. FREESTANDING SIGN Hotels are allowed freestanding signage according to the same to the same standards as other businesses. No signs or sign supports which obscure vision between the heights of 3 and 10 feet within 40 feet of the intersection of streets or driveway will be allowed. C. \homepage4ukwila\dcd\apps\C&IZONES. DOC 08/15/00 MAXIMUM HEIGHT • • The maximum height of a . freestanding sign is the height of the building it is associated with or 35 feet, whichever is less. Exceptions are as follows: • Signs in industrial zones may have a maximum height of 45 feet. • For commercial sites larger than 10 gross acres, the maximum sign height increased 2 feet for each additional increment of 5 acres of land. However, it still cannot be taller than the building it is associated with. WALL SIGN STANDARDS Wall sign area is based on the area of the building face to which the sign will be attached. For buildings with multiple tenants, use only the wall area in front of the space that the business owns or leases. See the definition of "Exposed Building Face" in the definitions handout. Area (LxH) of the Exposed Building Face in Square Feet O to 500 501 to 1,500 1,501 to 3,000 3001 to 5,000 Over 5,000 SPECIAL REQUIREMENTS Maximum Wall Sign Area in Square Feet 0.05 x Exposed Building Face (EBF) in square feet 25 + 0.04 x (EBF -500) 65 + 0.03 x (EBF -1500) 110 + 0.02 x (EBF -3000) 150 sq. ft. maximum • Wall sign area may be increased up to 50% for each doubling of the required building setback distance to the wall on which the sign is to be mounted. For example, if the zone requires a 20 foot setback and the wall sign will be placed on, is 40 feet from the property line, it would be eligible for the increase. Special permission is required and the sign area may not be larger than 6% of the exposed building face or 500 square feet, whichever is less • Freeway Interchange Businesses (eating, lodging and service stations) located within a radius of 1,000 feet from a freeway interchange, are allowed to increase the height and area of their freestanding sign by 25% with special permission. OFFICE BUILDINGS WITH MULTIPLE TENANTS Tenants in traditional office buildings with a common public entrance, are allowed a total of two signs, with no more than one sign on any building face. All wall signs on an exposed building face, may share the same sign area, (calculated according to the table area,) without special permission. Freestanding signs are allowed according to the same standards as other businesses. Each group of professional offices, may have a directory, listing the names of the tenants, on-site and a location map. The directory shall be oriented to the pedestrian on the site rather than the passing motorist. Multi -tenant office and commercial buildings are allowed signage according to the same standards as other businesses. C:\homepageltukwilatdcd/apps\C&IZONES.DOC 08/15/00 Electric Signs Electronic Message Displays Custom Neon Systems Sales, Repair & Maintenance October 20, 2006 Jaimie Reavis CITY OF TUKWILA Dept. of Community Development 630.0 Southcenter Blvd., Suite 100_ Tukwila, WA 98188 RE: Sign Permit S06-060 Jaimie, RECEIVE 'OCT 2 01006 DEVELOPMENT 9800 Harbour Place, Suite 208 Mukilteo, WA*98275 Telephone (425)'349 - 5044 FAX (425) 349 - 5045 Per our phone conversation, enclosed is our check #9914 in the amount of $115.00. This is to replace our original check #9907. Please write VOID on our original check and return with our completed sign permit. Please feel free to call if you have any questions. Thank you, ona Hansen Bookkeeper APOLLO NEON, INC 425-349-5044 City of Department olmmunity Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 206 431-3670 PER %!/ S(9 o&0 DAgr 2 0 _pL DEvE guNiry • Di,./\- a\ e-k-vt4r Auainese Nay® Appl Con tor 1.6600 Address of Sign a.Y%Ou,- Address, City, State, 4 p Pleas. print lac '1/ iTD (eta -s) as (- 6 oyuk C(`6r}'7j Phone C1 %a..5 Phone 9Too 4{2rbour . 12.Ct,--S2 aO% J�� \eco 01)-S) 3yu - JDLitt Address, City, Stade, Zip Phone CHECKLIS Separate application required for each sign proposed 3 sets of plans are required, Including site pian showing: • Property lines • Streets • Buildings • Locations of all existing and proposed signs 9- Sign elevations with area caiculations and dimensions O Building elevations (for wall signs) • Supporting structure and method of illumination (3^'/ One copy of valid Washington State contractor's license (, 550 application fee per sign See back of form for examples Is the sign: tinternally lit SIGN`. 0 Externally lit 0 Not lit Does the'bign face residential zones or public facilities? O Yes EgAo Exposed neon tubing is not allowed within 200 feet of LDR, MDR or HDR sones. Did building go through design review? ❑ Yes ❑ No including this sign, how many signs will flet this business? Freestanding 1 Wali D WALL SiGN: What is the wail area (length x height) where the sign will be mounted? ' square feet Wali sign size: square feet Does wall sign weigh more than 400 pounds? ❑ Yes 0 N if the sign weighs more than 400 pounds it requires structural review—ass checklist locaddltiodal Information required: is your sign a: ❑ Freestanding sign 16 or more feet In height Dole sign with face 30 square feet or more in area ❑ Wail sign weighing 400 pounds or more 1f any of the above are true you must go through structural review. STRUCTURAL REVIEW CHECKLIST: 13184 for structural review (if actual cost to the City is greater, you will be billed when you pick up your permit). ❑ Construction details to describe the proposed foundation or wail attachments (see back of form for examples) ❑ Structural calculations for the design of the details prepared by a Washington State structural engineer RIPTiON FREESTANDING SIGN: Street frontage of the entire tot where the sign will be located: feel Generally, only one freestanding sign is allowed per lot. Size of sign face: square feet Structural review is required for pole signs with faces 30 square feet or more in area, see checklist for additional Information required. Number of sign faces: Height of building: �� feet Generally, signs may not be higher than the building they are aaaociated with. Sign height (0 feet 0 inches Structural review le required for signs 15 feet or mare in height, see checklist. for additional information required. Distance from closest edge of sign to property lines: J (z feet Generally, signs must be set back from all property lines at least as far as they are high. it the sign needs structural review, the applicant or installer is required to call the Building Division at 431.3670 for footing or bracket inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is installed. A final inspection is required for ell signs when installation is complete. The applicant or installer is required to call the Planning Division at 431-3670 for a final inspection. It Is the responsibility of the installer to obtain the electrical permit and inspections frorn the Washington State Department of Labor and industries at (206) 248-6630. (NOTE: 1F A FINAL INSPECTION HAS NOT BEEN REQUESTED WITHIN 180 DAYS OF PERMIT ISSUANCE THE PERMIT WILL EXPIRE.) 1 MEREBY CERTIFY that the above information furnished by me Is true and correct under penalty of perjury by law in the State of Washington, and that the applicable requirements of the City of Tukwila wItI be met Date ' Zoning: (Signature of owner or author zed agent) FOR OFFICE USE ONLY Planning review by: O Denied 0 issued C H as) '3114 -Cg Lit/ _ Phone 0 Issued with conditions Structural review required? 0 Yea 0 No Actual time spent to review Comments or Conditions: Structural review by: O Denied 0 Approved 0 Approved with conditions Additional charges for time over 2 hours • • T',,ICsiis i .AS: PRowbrp LEC CON'Ilt SIG hl Ail s {n • APOLLO. NEON INC 9.8 0 0 • liARPOUR PL #108 : _ MUKIL Z'EO,w; 98275 .' F625-052.000 {81971 Detach And Display Certificate • Structural Design Associates North Star Building 2210 Hewitt Avenue, Suite 401 Everett, Washington, 98201 Phone: (425) 339-0293 Fax: (425) 252-0916 STRUCTURAL CALCULATION Sign Column and Footing Only SDA Ref. # 4582 West Valley Highway Kent, WA 10/05/06 RECEIVED OCT 2 0 2006 COMMUNITY DEVELOPMENT • • y %W.." - . FtPOLLID N E0i4 io itS/0 4-58' - Ew s 1 C"N L -0c4-' 11. Ems' '" �,�.4 . t. J C c. c �.r-r4� �3c.� t� a •-, I r.e 3 p., . e -t -i /2,e1 ?F 5, c. ;'SF 4.0,1-19 Lo' -- 1 (o (S � ,c)) = 8 g // C7' ss, S Pc.- F Co� Levitz I r G.. I `r'" , ; ✓ r " ^_ 3 ' - I f - r/ 14, t. ►eta Il ►1 £!N S UPPDK1 c OL ����►► = PI FE Co STD WMPfd-CTED FILL i&:31-(0" X 3 ,_p„ X3 -LO DEEP Ray: 580008 User: KW -0603169, Ver 5,8.0, 1.Oec-2003 (c)1983-2003 ENERCALC Enpheednp 9GRwere Description • • Title : Dsgnr: Description : Scope : Job Date: 10:24AM, 5 OCT 06 f' Steel Beam Design Page 1 I General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Fy 36.00ksi Load Duration Factor 1.33 Elastic Modulus 29,000.0ksi Steel Section : P6STD Center Span Left Cant. Right Cant Lu : Unbraced Length Distributed Loads #1 DL 0.005 LL 0.089 ST Start Location End Location 0.00 ft 0.00 ft 10.00 ft 0.00 ft #2 Fixed -Free Brn Wt. Added to Loads LL & ST Act Together Note! Short Term Loads Are WIND Loads. ` #3 #4 05 #6 #7 km k/ft km ft ft Using: P6STD section, Span = 0.00ft, Fy = 36.0ksi, Left Cant. = 0.00ft, Right Cant. = 10.00ft End Fixity O Fixed -Free, Lu ss 0.00ft, LDF = 1.330 Moment fb : Bending Stress fb/Fb _AsaitaL Allowable 5.552 k -ft 16.830 k -ft 7.838 ksi 23.760 ksi 0.330 : 1 Shear 0.000 k 28.732 k fv : Shear Stress 0.000 ksl 14.400 ksi fv / Fv 0.000: 1 Deflection Quite High l Static Load Case Governs Suess Max Deflection Length/DL Dell Length/(DL+LL Defq -0.012 In 0.0:1 0.0 : 1 (Force & Stress Summary «- These columns are Dead + Live Load placed as noted -» DI LL LL+ST LL LL+ST Magnum Only Center et Center (lCants Cants Max. M + 5.55 k -ft k -ft Max. M - -5.55 -5.55 k -ft Max. M @ Left k•ft Max M 0 Right k -ft Shear Q Left k k Shear ia Right k k Center Deft. Left Cant Deft Right Cant Deli ...Query Deft .r -0.0121n -0.012 -0.012 -0.012 0.000 0.000 In 0.000in 0.000 0.000 0.000 0.000 0.000 In 0.000 in 0.000 0.000 0.000 0.000 0.000 in 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction Left Reaction Rt Fa caic'd per Ea. E2-1, tCL/r < Cc re -action Properties P6STD Diameter 6.630 in Weight 18.95 #/ft hoc 28.100 1114 lyy 28.100 1n4 Thickness 0.280 in Sxx 8.500 in3 Area 5.58 in2 Syy 8,500 In3 R-xx 2.250 in Values for LRFD Design.... R-yy 2.250 in .1 56.3001n4 Zx 11.300 in3 Zy 11.300 in3 Title : Dsgnr: Description : Scope: f Rev: 580002 1 User. KW -0603168, Ver 6.8.0, 1 -pee -2003 pole Embedment in Soil L4oj1983.2003 ENERCALC Engineering Software Description Circular pole with Uniform Loads Job # Date: 10:36AM, 5 OCT 06 Page 1. General Information Allow Passive Max Passive Load duration factor Pole is Rectangular Width No Surface Restraint Summary Moments (a Surface... Point load Distributed load 250.00 pcf 1,500.00 psf 1.330 36.000 in Code Ref: 1997 UBC 1806.8.2.1, 2003 IBC 1805.7.2, 2003 NFPA 5000 36.4.3 Applied Loads... Point Load distance from base Distributed Load distance to top distance to bottom 0.00 lbs 10.000 ft 93.00 #Jft 10.000 ft 0.000 ft Without Surface Restraint... Required Depth Press ift 1/3 Embed... Actual Allowable 0.00 ft-# 4.650.00 3.600 ft 382.51 psi 383.72 pef Total Moment Total Lateral 4,650.00 ft# 930.00 lbs Rev: 580002 ! User: KW -0603169, Vet' 5.8.0, 1 -Dec -2003 (c)1983-2003 ENERCALC En. inearin. Software Title : Dsgnr: Description : Scope : Pole Embedment in Soil Description Circular pole with Uniform Loads General Information Allow Passive Max Passive Load duration factor Pole is Rectangular Width 4o Surface Restraint flaw Summary Moments ta Surface... Point load Distributed load 250.00 pcf 1,500.00 psf 1.330 42.000 in IC., Job # Date: 10:35AM, 5 OCT 06 Code Ref 1997 UBC 1806.8.2.1, 2003 IBC 1805.7.2, 2003 NFPA 5000 36.4,3 Applied Loads... Point Load distance from base Without Surface Restraint.., Required Depth Press tg22 1/3 Embed... Actual Allowable 0.00 ft -it 4,650.00 3.376 ft 360.29 . psf 382.01 psf Distributed Load distance to top distance to bottom Total Moment Total Lateral 0.00 lbs 10.000 ft 93.00 #tft 10.000 ft 0.000 ft 4,650.00 ft4 930.00 lbs • Iwt.14/‘U1ID ‹I'L.14'3b045 111 APOLLO NEON INC 4 582 PAGE 02 maamminemine. 241n 1 f 6 ft a in le in Haft sided 11120114100 moment Ora with polvaarbeite feces and benthmeal vivid mike. Adam's' MIAs In vinyl pipits. Or. &Ater 1-3-011 -p@FED/71-.Er-D-) ELEVATION scale: 3/4'1=1" NON -ILLUMINATED ALUMINUM CABINET VINYL GRAPHICS DOUBLE FACED — CABINET SIGN PAINTED TO MATCH PMS7461C TRANSLUCENT POLYCARBONATE FACES TRANSLUCENT & OPAQUE VINYL GRAPHICS INTERNAL ILLUMINATION VIA 800MA FLUORESCENT LAMPS ALUMINUM BASE COVER CENTER POLE MOUNT SEE INCLUDED -ENGINEERING SIGN AREA: 60 SQ. FT. 5°8°B 5°06° c AOC) �I\,,flIy i LJ V <425)25 —, 1-6044. , MEM n 0 n -CQ1 (425) 2 5 aeon MT2 1-6044 Mar:10- (425) 25 MaiM 1-6044 6eOee co o SITE PLAN scale: °°=50e • • Specs: Double sided illuminated monument sign with polycarbonate faces and translucent vinyl graphics. Address digits in opaque vinyl graphics. Project Advanced Care Dental Center, 16600 West Valley Highway, Tukwila, WA Date 10-11-06 RECEIVED OCT 2 0 2006 DEVELOPMENT 1 This drawing has been produced exclusively for use by Apollo Neon, Inc. It is not to be distributed or displayed without written permission from Apollo Neon, Inc. This drawing may be purchased from Apollo Neon, Inc. ELEVATION scale: 3 4 "_ —1 ' NON -ILLUMINATED ALUMINUM CABINET VINYL GRAPHICS DOUBLE FACED CABINET SIGN PAINTED TO MATCH PMS 7461C TRANSLUCENT - POLYCARBONATE FACES TRANSLUCENT & OPAQUE VINYL GRAPHICS INTERNAL ILLUMINATION VIA 800MA FLUORESCENT LAMPS ALUMINUM BASE COVER CENTER POLE MOUNT SEE INCLUDED -ENGINEERING - SIGN AREA: 60 SQ. FT. 5'8" 4 ( .6) CO) (425) 25 L J 1-6044 1 _ia (425) 25 aeon 712T2 1-6044 N7 371_ (425) 2 vMOvM 1-6044 5 >1 6'0" 0 SITE PLAN scale: 1 °'=50' Specs: Double sided illuminated monument sign with polycarbonate faces and translucent vinyl graphics. Address digits in opaque vinyl graphics. Project Advanced Care Dental Center,16600 West Valley Highway, Tukwila, WA REcEll ED Date: 10-11-06 OCT 2 0 2006 COMRflUNITY DPvELOPMENT IThis drawing has been produced exclusively for use by Apollo Neon, Inc. It is not to be distributed or displayed without written permission from Apollo Neon, Inc. This drawing may be purchased from Apollo Neon, Inc. Property comer pin in pavement 191.27' en comm. am aim=m. --- „A3 Property line 0 c0 rn Property comer pin in street pavement See enlarged view on Sheet 2 SITE PLAN SCALE: 1" = 30' mrmini.-.1mo -- imam. -----=--- ammo ..... .411=1=ND- 191.00' West Valley Hwy / SR 181 RECEIVED DEC 1 8 2006 commuNiTy DEVELopm NT Owner: Aulakh Buttar & Cantor LLC 1001 Fourth Avenue Plaza Suite 2303 Seattle, WA 98154 Ph. 425-251-6044 (Dr. Sukhminder S. Buttar) Fax 425-251-6088 Site address: 16600 West Valley Hwy Building 'B' Suite 103 Tukwila, WA 98188 Parcel ID # 252304908509 Legal description: 252304 85 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 86-18 SS RECORDING NO 8707281477 SD SHORT PLAT DAF - POR OF S 990 FT OF SE 1/4 OF NW 1/4 LY E OF WEST VALLEY RD & LY W OF PUGET SOUND ELECTRIC RAILWAY R/W & LY N OF FOLG DESC LINE - BEG CENTER OF SEC 25 TH W ALG THE C/L OF SEC 25 897.56 FT TO AN INTSN WITH C/L OF CHICAGO, MILWAUKEE ST PAUL & UNION PACIFIC RR R/W TH SLY ALG SD RR C/L 517.40 FT TH N 46-27-30 WTO WLY LN OF PUGET SOUND ELECTRIC RAILWAY R/ WAS CONDEMNED IN KC SUPERIOR COURT CAUSE NO 32873 TH CONTG N 46-27-30 W TO ELY LN OF WEST VALLEY RD TH NLY ALG SD ELY LN 460 FT TO TPOB OF THE LINE HEREIN DESC TH E TO WLY LN OF PUGET SOUND ELECTRIC RAILWAY R/W & TERM OF SAID LINE Lot area: 17,497 SF Project descrition: Install a free standing ground sign. Buttar & Cantor Law Offices Advanced Care Dental Center 16600 West Valley Highway, Tukwila, WA 98188 o - (a 0 Sheet • • • Parking Sign location (Sign not to scale) 5'-O" Planting strip (Grass) Planting strip (Grass) Sidewalk Property line Planting strip (Ivy) Property comer pin in street pavement_ NORTH West Valley Hwy / SR 181 ENLARGED SIGN LOCATION SITE PLAN scale: 1/8" = 1-0" Driveway Buttar & Cantor Law Offices Advanced Care Dental Center 16600 West Valley Highway, Tukwila, WA 98188 Sb( 0(00 RECEIVED DEC 1 81006 coppivImuurry c irELOPga N Sheet 2