HomeMy WebLinkAboutPermit S07-039 - NORDSTROM RACKNORDSTROM RACK
17250 SOUThCELNTER PY
S07-039
City otl'ukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
PERMANENT SIGN PERMIT
Parcel No.: 2623049117
Address: 17250 SOUTHCENTER PT TUKW
Suite No:
Permit Number: S07-039
Issue Date: 07/03/2007
Permit Expires On: 12/30/2007
Business:,:
Name: NORDSTROM RACK Phone:
Address:
Property Owner:
Name: WIG PROPERTIES LLC -SS
Address: 4811 134TH PL SE
Contact Person:
Name:
Address:
Phone:
Phone:
Contractor:
• Name: CDI Phone:
Address: 423 KENTUCKY ST
DESCRIPTION OF WORK:
Wall sign for Nordstrom's Rack
Fees Collected: $120.00
PERMANENT SIGN:
Zoning: TUC Sign Type:
Wall Sign #1 Wall Sign #2 Wall Sign #3 Wall Sign #4
Wall Area (sq. feet): 5488 0 0 0
Wall Sign Size (sq. feet): 125 0 0 0
Sign Lighting:
Face Residential Land: N
Freestanding Sign #1 Freestanding Sign #2
Street Frontage for Entire Lot: 0 0
Building Height (feet): 0 0
Sign Size (sq. feet): 0 0
Sign Height (feet and inches): 0 ' 0 " 0 ' 0 "
Setback (feet): 0 0
Number of Sign Faces: 0 0
Planning Division Authorized Signature:
odj131>7
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
THIS PERMIT SHALL BECOME NULL AND VOID IF THE WORK IS NOT COMMENCED WITHIN 180 DAYS FROM THE DATE OF
ISSUANCE, OR IF THE WORK IS SUSPENDED OR ABANDONED FOR
A PERIOD OF 180 DAYS FROM THE LAST INSPECTION.
doc: SIGN -PERM
S07-039 Printed:
SITE INSPECTION (PLAN
File No. S07-039
Name of Tenant: Nordstrom Rack
Sign Address: 4811 134th P1 SE
Date Photo Taken: September 5, 2007
x
ING)
Sign appears to conform to permit application
Sign appears different from permit application
Sign not installed as of 8/10/2007
Make new site visit and take photo by 02/10/2008
Comments: Wall sign inspected 9-5-07 and approved as applied. Stacy MacGregor
• •
SITE MAP
tl0ADS1ROU RAU;
SOUTI NTEA PEW`!
RECEIVED
'J W 21 2007.
ommuNny
SOUTHCENTER RACK (003)
17200 SOUTHCENTER PARKWAY SUITE 110
TUKVVILA, WA 98188
JOB NUMBER 206437.00
•--RECE
taU 21 2001
DIVELOMENT
OM Oa 1.111ERS RIX_ .. INORDSTR7OM i
I.
3 5/8- tilt silos
1
Cm ®IC(Y STPD
rK P >%* T[R P,PD,,s,
C'ES. STORE PM,
SOCKP KP . L.IOM P
KP MSR• : .:TMS.MK If 14.41A101 OAS,
A9 ROOF PLAN
9UILDINo
ANA
7
8
3)
9
10
11
278"
ILLUMa9ATED TENANT SIGNAGE
WHITE FACE LETTERS WITH WHITE
RETURNS. SIGNAGE AREA EOUALS
148 SF. UNDER SEPARATE PERMIT.
12
6)
13
;_71
NORDST OM
Ra-ocK___.
n
REMOVE EXISTING HOLLOW -
METAL DOOR & FRAME;
INFLL WITH CONCRETE &
PAINT TO MATCH ADJACENT
J,sn}Dne�.
EXTERIOR ELEVATION
KEYPAD & INTERCOM
INSTALLED IN 9" X 18"
16 GA OREAKMETAL
BACKING. BREAKMETAL
INSTALLED 0 42" AFF
•
STORE HOURS IRS360)
WINDOW GRAPHIC
NORDSTROM RACK
WINDOW GRAPHIC. TYPICAL
AT STOREFRONT WINDOWS
1
' :" - . . . .':1.. . c; ;H"-'7(iffilTUTfra 1 ft. IIID IIL�III4170„_ � 'll Ilt �=
�inuE� Ili iiiii 11 111 _. amnrir*r'
1
14
0
r\
0
z
co
N
a
0
Odvo
N ~ c
7 rn
c c la o
.< O) L V N
> o0 V V
$ 0 O
ILLUMINATED TENANT SIGNAGE
WHITE FACE LETTERS WITH WHITE
RETURNS. SIGNAGE AREA EQUALS
148 SF. UNDER SEPARATE PERMIT.
N 0 RDSTRO
RdCK
unnun,lnnum
f
IHII 111111 11111 1 _. _ _. 1111111111111111
jr11 11
!I II
—l1iL•
Ill 11111111111 II11111111111111111111
111111111111111111111111111 11111111"' "" "1I'11"""' """'In111111111111n11111111 1111111111
IT
111 1111111111
1111111IIIHIIHII 1111 11111111111
1111111111111111 1111111111 11111111
ON
KEYPAD & INTERCOM
INSTALLED IN 9" X 18"
16 GA BREAKMETAL
BACKING. BREAKMETAL
INSTALLED @ 42" AFF
STORE HOURS (RS360)
WINDOW GRAPHIC
NORDSTROM RACK .
WINDOW GRAPHIC. TYPICAL
AT STOREFRONT WINDOWS
.063 THICK ALUMINUM
RETURNS PAINTED P1
1/4" S.S. RIVETS TO
RETURNS AND BACK
OR WELD
3 1/2"
1/4"
3/8" NUTCERT
AGILIGHT
SIDEWINDER
165 LED
i" THREADED ROD WITH
NUTS AND WASHERS
CAULK ALL PENETRATIONS
THRU WALL
38 3/4"
DRIVER
8'-716"
EXISTING
WALL
INTERIORQF LOGO TO BE
PAINTED P FOR MAXIMUM
REFLECTIO
.090 THICK ALUMINUM
BACK
#429LT2 ELECTRICAL
JUNCTION BOX
NOT BY COLITE
COUPLING & 1/2" DIA.
WATERTIGHT CONNECTOR
1" X 1" ALUMINUM ANGLE
LIGHT SHIELD OVER
1/4" DIA. WEEP HOLES
#8 S.S. SCREW
i" SPACERS
SECTION
NTS
PACKING LIST
MATERIAL
QTY
CHECK
1
CHECK
2
INSTALLER
CHECK
LETTERSET
1
MOUNTING PATTERN
1
i" THREADED ROD
50
4" NUT
100
4" WASHER
50
TOUCH—UP PAINT
1
CLASS (2) POWER SUPPLY
MODEL: LP1060-12—GG-290
7
NOTE: PLEASE FAX TO YOUR COLITE CONTACT WITH
HOURS TO VERIFY PRODUCT AND PACKING LIST ITEMS
RECEIVED IN TOTAL.
FAX #(803) 926-8412
N 24-48
WERE
5'-416"
2'-18" —
120V POWER SUPPLY
LINE WITH CONDUIT
CLASS (2) POWER SUPPLY
MODEL: LP1060-12—GG-290
AC INPUT: 100-240VAC,
1-0.5A, 47-63Hz DC OUTPUT:
60 WATTS, 12V / 5.OA
LED WIRES
1000 VOLT BALLAST WIRE 14 GAUGE
WATERPROOF OUTLET BOX
BLACK/RED
BELDEN WIRE CL2
PAINT SPECIFICATIONS:
0 MATTHEW'S N202 WHITE
SPRAYLAT B70-400 BRITE STAR
ACRYLIC SPECIFICATIONS:
Al 3/g THICK #7328 WHITE ACRYLIC
TRIM CAP SPECIFICATIONS:
0 TRANSCO WHITE # 96724
TRIM CAP
EQ.
BLACK LED WIRE
CONNECTED TO
BLUE WIRE
RED LED WIRE
CONNECTED TO RED WIRE
ELEVATION
SCALE: 1/4"=1'-0"
BLACK/RED BELDEN
WIRE CL2
LED WIRES 1000 VOLT —
BALLAST WIRE 14 GAUGE
MALE AND FEMALE CONNECTION DETAIL
NTS
SPLICE CONNECTION BOX AND
TRANSFORMER MUST NOT BE
EXPOSED TO OUTSIDE WEATHER
CONDITIONS.
THIS SIGN TO BEAR
UNDER' RITERS LABEL
120 VOLTS
NOTICE TO SIGN INSTALLER.
THE VOLTAGE AT THIS SIGN
MUST BE 120±6 VOLTS FOR
THIS SIGN TO OPERATE
PROPERLY
FOLDER REQUIREMENTS
Reviewed By
Date
FILE PATH:
GRAPHICS ON GC1
NORDSTROMS
STACKED ART.FS
❑ Planning
Shipping
Purchasing
❑Purchasing (Material)
❑Purchasing (Subcontractor)
D Laser cut
❑Water Jet cut
Din House Neon
❑ Purchasing (LED)
CI LED Production
❑Routing
❑Face BC ❑Back BC
❑ Mounting Pattern
Graphics
Mounting
❑ Mounting Pattern
❑Shop
DAs Built
D
c
B
A
REV
11
BW
LW
HW
HW
BY
6-13-07
6-01-07
5-30-07
5-17-07
DATE
LETERSET WAS 30 11/16'
UPDATED TITLE BLOCK INFORMATION
DRIVER DIMENSION WAS 33"
CHANGE ACRYLIC SPEC.
DESCRIPTION
UNTIE
229 PARSON ST. . P.O. BOX 4005 • WEST COIUM
THIS IS AN ORIGINAL UNPUBUSHED ❑ESI
SUBMITTED FOR YOUR PERSONAL. USE I C
COUTE INTERNATIONAL LTD. IT IS NO
NOR IS IT TO BE USED, REPRODUCED.
ANY PART OF THIS DESIGN (EXCEPTIN
COUTE INTERNATIONAL LTD. ` _
NzJATr'I(#)N
29171
AL LTD.
PH. (805) 928-7928
0.6875" LED LE#
D BY COUTE INTERNATIONAL LTO. IT IS
N WITH THE PROJECT PLANNED FOR YOU BY
7/11 TO ANYONE OUTSIDE YOUR ORGANIZATION;
EXHIBITED IN A/47 FASHION WHATSOEVER. AU. OR
STERED TRADEMARKS) REMAIN TME PROPERTY OF
CUSTOMER:
NORDSTROM
LOCATION:
TIXWILA, WA
DATE
04-13-07
DRAWN 8Y:
BDM
PROJECT MANAGER:
L BULL
CHECK BY:
SCALE
DRAWING NUMBER
07-0838
SHEET 1 OF 1
WORK ORDER N0.
24985
RECEIVED
i o 212001
p4pPNENT
Citf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite 100 DATE:
Tukwila, Washington 98188
206 431-3670
PERMIT NO. 031 —V /
to
-1\ -07
PERMANENT SIGN PERMIT APPLICATION
Noes+nowt Krick
Business Name
ct
Applicant/Contact
�]
Please print L
17aoo Sourii,coe k
t- PA wMy
Address of Sign 7 Phone
1- 6�ca -Ittk cs-1 . 3( I!i',S1,RA I (dPr 9822,13 ('v -6.-S-61•-11 S°
ddress, City, State, Zip Phone
DT 4L3 ech.44ck 44^fWR5rz2s' 360-656—!!r4c:•
Phone
Cractor
Address, City, State, Zit!
3 sets of plans (dimensioned and scaled), including
site plan showing:
• Property lines
• Streets
• Buildings
• Locations of all existing and proposed signs
Sign elevations with area calculations and dimensions
Building elevations (for wall signs)
Supporting structure and method of illumination
One copy of valid Washington State contractor's license
$120 application fee per sign
See back of form for examples
Is your sign a:
❑ Freestanding sign 15 or more feet in height
❑ Pole sign with face 30 square feet or more in area
❑ Wall sign weighing 400 pounds or more
If any of the above are true, the application must go
through structural review..
STRUCTURAL REVIEW CHECKLIST:
❑ $84 for structural review (if actual cost to the City is
greater, you will be billed when you pick up your permit).
❑ Construction details to describe the proposed foundation or
wall attachments (see back of form for examples)
❑ Structural calculations for the sign shall be prepared by a
Washington State structural engineer
SIGN DESCRIPTION
How many signs will list this business? Freestanding
Did building go through design review? Yes 0 No
Wall
WALL SIGNS:
#1
#2
#3
#4
Wall area (length x height) of the tenant space where the
sign will be mounted? (square feet)
sii�fl
�/
Sign size(square feet)
f 2,S5f.43.
Does sign face residential zones or public facilities? (Y/N)
Exposed neon tubing is not allowed within 200 feet of
LDR, MDR or HDR zones.
Does wall sign weigh more than 400 pounds?(Y/N)
AI
Sign illumination (internal/external/none)
ThAcetsgt
FREESTANDING SIGNS:
#1
#2
Street frontage of the entire premises where the sign will be located (feet). Generally, only
one freestanding sign is allowed per premises.
Height of building (feet). Generally, signs may not be higher than the building with which they
are associated
Size of sign face (square feet). Structural review is required for pole signs with faces 30 square
feet or more in area
Sign height (feet -inches). Structural review is required for signs 15 feet or more in height.
Distance from closest edge of sign to property lines (feet). Generally, signs must be set
back from all property lines a distance equal to their height.
Number of si • n faces
INSPECTIONS -
If the sign needs structural review, the applicant or installer is required to call the Building Division at 431-3670 for foo ing or bracket
inspections. Footing inspections must take place before concrete is poured. Bracket inspections must take place before sign is
installed.
A structural inspection is required for all signs when installation is complete. The applicant or installer is required to call the Planning
Division at 431-3670 for a final inspection.
It is the responsibility of the installer to obtain the electrical permit and inspections from the Washington State Department of Labor and
Industries at (206) 248-6630.
SIGN PERMIT APPLICAT • N IS V4JJD FOR 180 DAYS AFTER ISSUANCE.
!HEREBY CERTIFY that the above information furni
the applic ble requirements of the City of Tukwila
(4° v
Date
ect under penalty of perjury by law in the State of Washington, and that
authorized age
kenssty-gI�dA/.ccs
ail Address
FOR OFFICE USE ONLY
Zoning:
Planning review by:
O Denied
0 Issued
0 Issued with conditions
Structural review required? 0 Yes 0 No
Structural review by:
O Denied 0 Approved 0 Approved with conditions
P:\ Planning Forms\ Applications\ PermSign-12-06.doc
on 12/20/01
Revised
F625 -052 -OU( (8/971
DEPARTMENT OF LABOR AND INDUSTRIES
REGISTERED AS PROVIDED BY LAW AS
CONST CONT GENERAL
REGIST. #- EXP. DATE
CCOl- CDICUDI972MG 07/06/2008
EFFECTIVE DATE 07/07/2003
C D I CUSTOM DESIGN INC -
423 KENTUCKY ST
BELLINGHAM WA 98225
Detach And Display Certificate
DEPARTMENT OF LABOR AND INDUSTRIES
LICENSED AS PROVIDED BY LAW AS
ELEC CONTR GENERAL
LICENSE # EXP. DATE
ECO1 CDICUCD950KW 05/09/2009
EFFECTIVE DATE 05/09/2005
CDI CUSTOM DESIGN INC
423 KENTUCKY ST
BELLINGHAM WA 98225
F625-052-000 (8/971
Detach And Display Certificate
DEPARTMENT OF LABOR AND INDUSTRIES
CERTIFIED AS PROVIDED BY LAW AS
MSTR,ELEC GENERAL
CERT # EXP. DATE
ME01 LANKHDa*96.90Z 09/10/2007
EFFECTIVE DATE 09/09/2004
LANKHAAR, DON
7021 TALL CEDARS
FERNDALE WA 98248
F625 -052-0U0 (8/971